Dell OpenManage Server Administrator Version 7.4 Command Line Interface Guide
Contents
1. DDR3 Synchronous Registered Buffered 8192 MB 2 Ok DIMM A3 DDR3 Synchronous Registered Buffered 8192 MB 3 Ok DIMM A4 DDR3 Synchronous Registered Buffered 8192 MB If you specify the index Server Administrator displays a summary for a specific memory module displaying the health status device name type speed rank and failures A rank is a row of dynamic random access memory DRAM devices comprising 64 bits of data per Dual Inline Memory Module DIMM The possible values of rank are single dual quad octal and hexa The rank displays the rank of the DIMM and helps in the easy service of DIMMs on the server The following is an example output if you specify the index Memory Device Information Health Ok Status Ok Device Name DIMM Al Size 8192 MB Type DDR3 Synchronous Registered Buffered Speed 200575 AS Rank Dual Failures None NOTE To maintain consistency across the commands the output format of this command and the subsequent command levels has changed Change the user scripts as applicable Omreport Chassis Nics Or Omreport Mainsystem Nics Use the omreport chassis nics or omreport mainsystem nics command to view NIC and Team interface details On XenServer the command displays all the installed NICs regardless of driver installation NOTE The order in which devices are detected is not guaranteed to match the physical port ordering of the device To vie
2. Example to Example Removes the specified PCle SSD device from the cache pool omconfig storage pciessd action removefromcachepool subsystem id pciedevice lt PDISKID gt where id is the subsystem ID and lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage cachecade controllerzID to display the IDs for the cachecades of the controller Remove the specified PCle SSD device from the cachepool omconfig storage pciessd action removefromcachepool subsystem 2 pciedevice 0 2 0 force yes Omconfig Reactivate PCle SSD Device Description Syntax Reactivates the specified PCle SSD device that was part of the cache pool omconfig storage pciessd action reactivate subsystem id pciedevice lt PDISKID gt where id is the subsystem ID and lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage cachecade controllerzID to display the IDs for the cachecades of the controller 189 Example to Reactivate the specified PCle SSD device Example omconfig storage pciessd action reactivate subsystem 2 pciedevice 0 2 0 force yes Omconfig Fluid Cache Commands The following sections provide the omconfig command syntax required to execute fluid cache tasks Table 122 Omconfig Fluid Cache Commands Required
3. Required Command Levels 1 2 Optional name value pairs 3 and name value pair omreport storage enclosure controller id enclosure lt ENCLOSUREID gt info fans where id is the controller number and ENCLOSUREID is the enclosure number For example controllerzO enclosure 2 K NOTE For SCSI controllers the ID specified in enclosure lt ENCLOSUREID gt is the connector number and for Serial Attached SCSI SAS controllers ID is the connectorNumber Enclosur elndex controller id enclosure lt ENCLOSUREID gt info fans index n where id is the controller number and ENCLOSUREID is the enclosure number and n is the number of a fan For example controller 0 enclosure 2 info fans index 1 Omreport Power Supply Status Use Displays property information for all enclosures attached to the system Displays the fans for the specified enclosure Displays the specified fan The following table describes the syntax for the omreport Power Supply commands Table 71 Omreport Power Supply Commands Required Command Levels 1 2 Optional name value pairs 3 and name value pair omreport storage enclosure controller id enclosure lt ENCLOSUREID gt info pwrsupplies where id is the controller number and ENCLOSUREID is the enclosure number For example controller 0 enclosure 2 controller id enclosure lt ENCLOSUREID gt Use Displays property information for all enclosures attached to the system
4. omconfig storage controller action enablealarm controller id where id is the controller ID as reported by the omreport storage controller command Enable the alarm on controller 1 omconfig storage controller action enablealarm controller 1 Omconfig Disable Controller Alarm Description Syntax Example to Example Disables the controller alarm For more information see the Dell OpenManage Online Help omconfig storage controller action enablealarm controller id where id is the controller ID as reported by the omreport storage controller command Disable the alarm on controller 1 omconfig storage controller action disablealarm controller 1 Omconfig Quiet Controller Alarm Table 89 omconfig Quiet Controller Alarm Description Syntax Example to Example Silences an activated controller alarm For more information see the Dell OpenManage Online Help omconfig storage controller action quietalarm controller id where id is the controller ID as reported by the omreport storage controller command Quiet the alarm on controller 1 omconfig storage controller action quietalarm controller 1 165 omconfig Test Controller Alarm Table 90 omconfig Test Controller Alarm Description Syntax Example to Example Tests the functionality of the controller alarm The alarm sounds for about two seconds For more information see Dell OpenManage Online Help omconfig storage controller action testalar
5. 19 Conventions For Parameter Tableso s ect ade isn dt reia idos Command Summary Of The omreport Commande Help With The omreport Command tere ttt ene e ge e e da Eee nea Een onireport modu larernclosUre z n e e p ete e c n dde oue a ee usua ped aetna detente ell e OIA le e LEE Omreport Chassis Or Omreport Mainsystem Commande Omreport Chassis Acswitch Or Omreport Mainsystem Acswitch esssssee Omreport Chassis Batteries Or Omreport Mainsystem Batterles n Omreport Chassis Bios Or Omreport Mainsystem Blos Omreport Chassis Biossetup Or Omreport Mainsystem Biossetup BIOS Setup Parameters On Systems Prior To PowerEdge 12G Gwstems BIOS Setup Groups On PowerEdge yx2x Svstems eee Omreport Chassis Currents Or Omreport Mainsystem Currents Omreport Chassis Fans Or Omreport Mainsystem Fans Omreport Chassis Firmware Or Omreport Mainsystem Firmware Omreport Chassis Frontpanel Or Omreport Mainsystem Frontpanel n Omreport Chassis Fru Or Omreport Mainsystem Fu Omreport Chassis Hwperformance Or Omreport Mainsystem Hwperformance Omreport Chassis Info Or Omreport Mainsystem Into Omreport Ghassis IntruSiOF eon tee e ica Sirk ad d i be ea nil eade ite Omreport Chassis Leds Or Omreport Mainsystem Leds nnn Omreport Chassis Memory Or Omreport Mainsystem Memor Omreport Chassis Nics Or Omreport Mainsystem Nice Omreport Chassis Ports Or omreport Mainsystem Botz Omreport Chassis Processors Or Omreport Mainsystem DrocCeseors 56 Omre
6. Displays the power supplies for the specified enclosure Displays the specified power supply 137 Required Command Levels 1 2 3 and name value pair Omreport EMM Status The following table describes the sy NOTE The status of the EMMs firmware Table 72 Omreport EMM Commands Required Command Levels 1 2 3 and name value pair omreport storage enclosure Optional name value pairs Use info pwrsupplies index n where id is the controller number and ENCLOSUREID is the enclosure number and n is the number of a power supply For example controller 0 enclosure 2 info pwrsupplies index 1 ntax for the omreport EMM commands is displayed as degraded if there is a mismatch between the EMM Optional name value pairs Use Displays property information for all enclosures attached to the system controller id enclosure lt ENCLOSUREID gt info emms where id is the controller number and ENCLOSUREID is the enclosure number For example controller 0 enclosure 2 Displays the enclosure management modules EMMs for the specified enclosure controller id Displays the specified EMMs enclosure lt ENCLOSUREID gt info emms index n where id is the controller number and ENCLOSUREID is the enclosure number and n is the number of an EMM For example controller 0 enclosure 2 info emms index 1 Omreport Enclosure Slot Occupancy Report The following table describes the sy 138 ntax for the omrepo
7. Enabled diskcachepolicy enabled readpolicy ra nra ara rc nrc Different controllers support different read policies The following table displays how to specify the readpolicy lt ra nra ara rc nrc parameter for each of the read policies Table 96 Read Policy Parameters Read Policy readpolicy ra ara nra rc nrc Parameter Specification Read ahead readpolicy ra Adaptive read ahead readpolicy ara No read ahead readpolicy nra Read cache readpolicy rc No read cache readpolicy nrc writepolicy lt wb wt wc nwc gt Different controllers support different write policies The following table displays how to specify the writepolicy lt wb wt wc nwc fwb parameter for each of the write policies Table 97 Write Policy Parameters Write Policy writepolicy wb wt wc fwb nwc Parameter Specification Write back cache writepolicy wb Write through cache writepolicy wt Write cache writepolicy wc Force write back writepolicy fwb No write cache writepolicy nwc Controller id Specify the controller ID as reported by the omreport storage controller command For example controller 2 Raid lt c rO r1 ric r5 r6 r10 r50 r60 gt Use the raid lt c rO r1 ric r5 r6 r10 r50 r60 gt parameter to specify concatenation or a RAID level for a virtual disk Different controllers support different RAID levels For more information about RAID levels a controller su
8. action convertnonraidtoraid controller id pdisk lt PDISKID gt Omconfig Blink Physical Disk Description Blinks the light light emitting diode or LED display on one or more physical disks attached to a controller Syntax omconfig storage pdisk action blink controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk 144 Example to Example for SCSI SATA and ATA controllers Example for SAS controllers Omconfig Unblink Physical Disk Description Syntax Example to Example for SCSI SATA and ATA controllers Example for SAS controllers NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controllerzID to display the IDs for the physical disks attached to the controller Es Blink physical disk O on connector 0 of controller 1 On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action blink controller 1 pdisk 0 0 omconfig storage pdisk action blink controller 1 pdisk 0 2 0 Unblinks the light light emitting diode or LED display on one or more physical disks attached to a controller omconfig storage pdisk action unblink controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk K NOTE To obtain these values type omreport storage controller to display th
9. bios sequence aliasnamel aliasnamez aliasnameN sequence aliasnamel aliasnamez aliasnameN Description immediate System returns to previous state immediately e timedelay value System is turned on based on the user specified time delay enabled Enables the bezel removal intrusion check during system boot e disabled Disables the bezel removal intrusion check during system boot Instructs the BIOS which device is used to boot the system and the order in which the boot routine checks each device K NOTE On Linux systems user or user groups upgraded to administrator or administrator groups cannot configure this BIOS setup setting e uefi Enables the system to boot to operating systems that support Unified Extensible Firmware Interface UEFI e bios Enables the system to boot to operating systems that do not support UEFI Configures the boot sequence according to the set aliasnames To view the set alias names run the command omreport chassis biossetup attribute bootorder K NOTE On Linux systems user or user groups upgraded to administrator or administrator groups cannot configure this BIOS setup setting Configures the BIOS setup hard disk sequence according to the set aliasnames Changes takes effect after rebooting the system To view the set alias names run the command omreport chassis biossetup attribute bootorder 67 name value pair 1 attribut
10. 163 Required Command Levels Optional name value pairs 1 2 3 164 K NOTE If you set escrow yes specify the escrow file path action changesecuritykey controller id keyid lt keyid gt passphrase lt passphrase string oldpassphrase oldpassphrase string escrowzyes filepathz Absolute path to the escrow file gt A NOTE If you set escrow yes specify the escrow file path action deletesecuritykey controller id action setbgirate controller id rate lt 0 to 100 gt action setreconstructrate controller id rate lt 0 to 100 gt action setcheckconsistencyrate controller id rate lt 0 to 100 gt action exportlog controller id action importsecureforeignconfig controller id passphrase lt passphrase for imported foreign configuration gt action importforeignconfig controller id action importrecoverforeignconfig controller id action clearforeignconfig controller id action setpdiskpwrmanagement controller id spindownunconfigureddrives lt enabled disabled gt spindownhotspares lt enabled disabled gt spindownconfigureddrives lt enabled disabled gt idlec lt enabled disabled gt spindowntimeinterval lt 30 to 1440 gt minutes spinupstarttime lt HH MM AM PM gt spinuptimeinterval lt 1 to 24 gt hours Es NOTE Specify spinupstarttime and spinuptimeinterval only when you set spindownconfigureddrives enabled action setpatrolreadmode controller id mode lt manual auto disable gt action startpatrolread co
11. Table 52 Valid Parameters Of omconfig system assetinfo info depreciation or omconfig servermodule assetinfo info depreciation Command Command Command Name Value Name Value Description Level 1 Level 2 Level 3 Pair 1 Pair 2 omconfig system or assetinfo info depreciati duration lt n gt Number of years or servermodule on months over which a system is depreciated method lt text gt Steps and assumptions used to compute the system s depreciation percent lt n gt Portion of 100 that an asset is devalued or depreciated unit months Unit is months or years years 119 Example Command For Adding Depreciation Information To provide a value for a depreciation parameter type a command of the form omconfig system assetinfo info depreciation lt name value pair 2 or omconfig servermodule assetinfo info depreciation lt name value pair 2 For example type omconfig system assetinfo info depreciation method straightline or omconfig servermodule assetinfo info depreciation method straightline The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to the same name value pair 1 For an example see Example Commands For Adding Acquisition Information Adding Extended Warranty Information Use the omconfig system extwarranty o
12. omconfig storage controller action convertnonraidtoraid controller 0 pdisk 0 2 3 Omconfig Enclosure Commands The following table provides the omconfig command syntax required to execute enclosure tasks Table 105 Omconfig Enclosure Commands Required Command Levels 1 2 3 omconfig storage enclosure Optional name value pairs action enablealarm controller id enclosure lt ENCLOSUREID gt action disablealarm controller id enclosure lt ENCLOSUREID gt action setassettag controller id enclosure lt ENCLOSUREID gt assettag lt string gt action setassetname controller id enclosure lt ENCLOSUREID gt assetname lt string gt action settempprobes controller id enclosure lt ENCLOSUREID gt index id minwarn n maxwarn n action resettempprobes controller id enclosure lt ENCLOSUREID gt index id action setalltempprobes controller id enclosure lt ENCLOSUREID gt minwarn n maxwarn n action resetalltempprobes controller id enclosure lt ENCLOSUREID gt minwarn n maxwarn n action blink controller id enclosure lt ENCLOSUREID gt minwarn n maxwarn n Omconfig Enable Enclosure Alarm Description Example to 180 Enables the enclosure alarm Enable the alarm on the enclosure attached to connector 2 on controller 1 Example for SCSI SATA and ATA controllers Example for SAS controllers omconfig storage enclosure action enablealarm controller 1 enclosure 2 omconfig storage enclosure action enablealarm cont
13. software and storage Command Command Level Command User Use Level 1 2 Level 3 Privilege Required thrmshutdow DA Displays how to perform the shutdown n action if any when a temperature warning or failure condition is detected version U P A Displays a summary for all updatable components on the system preferences webserver U P A Displays the URL information of the Server Administrator Web server messages A Displays the configured alert message format Related Links omreport Viewing System Status Using The Instrumentation Service Help With The omreport Command Use the omreport command to get a list of the available commands for omreport Use omreport lt command level 2 gt to get help on the level 2 about chassis and system commands The following information on omreport system also applies to get help for the omreport chassis command To see a list of valid commands for omreport system type omreport system more omreport modularenclosure Use the omreport modularenclosure command to view details of the Blade system Type omreport modularenclosure NOTE This CLI command is available when Dell OpenManage Server Administrator is installed on Dell Blade systems Server Administrator displays information related to the modular enclosure and chassis management controller CMC if available K NOTE The output varies depending on the configuration of the system Modular Chassis Informatio
14. 1 pdisk connectorlD targetID connectorlD enclosurelD slotID where connectorID targetID is the connector number and the physical disk number and connectorlD enclosurelD slotlD is the connector number enclosure number and slot number For example pdisk 0 2 or pdisk 0 1 2 omreport Virtual Disk Status Use Displays all physical disks attached to the specified controller A NOTE If a physical disk was replaced by another disk as part of the replace member operation the state of the physical disk is displayed as Replacing Displays all physical disks included in the specified virtual disk on the controller Displays all physical disks included in the specified cachecade on the controller Displays all physical disks attached to the specified connector on the controller Displays the specified physical disk on the specified connector on the controller The following table describes the syntax for the omreport Virtual Disk commands 134 Table 66 omreport Virtual Disk Commands Required Command Levels 1 2 Optional name value pairs Use omreport storage vdisk Displays property information for all virtual disks on all controllers controller id where id is the Displays all virtual disks on the controller number For example specified controller controller 0 controller id vdisk id where id Displays the specified virtual disk is the controller number and the on the controller virtual
15. Active Directory service Omconfig Preferences Cdvformat Use the omconfig preferences cdvformat to specify the delimiters for separating data fields reported in the custom delimited format The valid values for delimiters are exclamation semicolon at hash dollar percent caret asterisk tilde question colon comma and pipe The following example shows how to set the delimiter for separating data fields to asterisk omconfig preferences cdvformat delimiter asterisk Omconfig Preferences Dirservice Use the omconfig preferences dirservice command to configure the Active Directory service The lt productname gt oem ini file is modified to reflect these changes If the adproductname is not present in the lt productname gt oem ini file then a lt computername gt lt computername gt refers to the name of the computer running Server Administrator and lt productname gt refers to the name of the product defined in omprv32 ini For Server Administrator the product name is omsa Therefore for a computer named myOmsa running Server Administrator the default name is myOmsa omsa This is the name of Server Administrator defined in Active Directory by using the snap in tool This name must match the name for the application object in Active Directory in order to find user privileges K NOTE This command is applicable only on systems running the Windows operating system The following table displays the valid parameters for
16. Administrator Storage Management guide at dell com openmanagemanuals Support for displaying and setting the JRE version See Omreport Preferences Commands and Omconfig Preferences Webserver Support for displaying Node Id in System Server Module Summary information See omreport system summary or omreport servermodule summary Support for new values for form factor aligning to DRAC values See omreport system summary or omreport servermodule summary Added support for Software RAID controllers PERC S110 on systems running the Windows Server 2012 R2 operating system Added support for Non Volatile Memory Express NVMe Peripheral Component Interconnect Express PCle solid state drives SSDs See the Server Administrator Storage Management guide at dell com openmanagemanuals NOTE Dell PowerEdge Express Flash NVMe PCle SSD devices support only the Dell provided Windows Server 2012 R2 64 bit drivers Added support for the following LSI Serial Attached SCSI SAS Host Bus Adapters HBAs on supported 12G systems LSI SAS 9207 8e LSI SAS 9300 8e LSI SAS 9206 16e Added support for the following Dell PowerEdge servers R920 R220 M820VRTX e Deprecated support for the following operating systems SUSE Linux Enterprise Server 10 SP4 SUSE Linux Enterprise Server 11 SP2 Red Hat Enterprise Linux 6 4 64 bit VMware ESXi 5 1 U1 HDD and Flash VMware ESXi 5 0 U2 HDD and Fl
17. Enables iSCSI on both the NICs 69 name value pair 1 attribute attribute embhypvisor attribute embvideoctrl attribute esataport attribute extserial attribute fbr 70 name value pair 2 setting setting enabled disabled setting enabled disabled setting off auto setting com1 com rad setting 9600 19200 57600 115200 Description niclisci Enables iSCSI on the first NIC and none no PXE or iSCSI on the second NIC nic2isci Enables none no PXE or iSCSI on the first NIC and iSCSI on the second NIC nic1pxenic2isci Enables PXE on the first NIC and iSCSI on second NIC nicliscinic2pxe Enables iSCSI on the first NIC and PXE on second NIC The following options are deprecated onpxeboth Enables PXE on both the NICs onpxenone PXE is not enabled on either of the NICs onpxenic1 Enables PXE on NIC 1 onpxenic2 Enables PXE on NIC 2 enabled Enables the embedded hypervisor disabled Disables the embedded hypervisor enabled Enables the embedded video controller as the primary video device disabled Disables the embedded video controller as the primary video device off Sets the embedded SATA port value to off auto Sets the embedded SATA port value to auto coml Maps the external serial connector to COM 1 com2 Maps the external serial connector to COM 2 rad Maps the external serial connector to the remote access device 9600 S
18. Erase Secured Physical Disk 146 Omconfig Initialize Physical Disk 147 Omiconfig Offline Physical DISK resies aiaei aai uim eter dec eC E Pe EP Ee 147 meontig Online Physical Disk ici er er tr eR REP ERR PEARCE RO RUE 148 Orriconfig Assign Global HotSpare urit eee er wien ep E aca 148 Omconfig Rebuild Physical DISK m etre e ret tp Pede eub ter obe tes etd ts 148 Omconfig Cancel Rebuild Physical Disk 149 Omeconfig Cancel Replace Member et t ng te is 150 Omconfig Clear Physical Disk ee enne eren 150 Omconftig carcel Clear Physical DISK pet p e EE Foe t de e re ede Peto det 150 Omconfig Enable Device Write Cache 151 Omconfig Disable Device Write Cache 151 Omconfig Export Reliability Log Omconfig Convert RAID To Non RAID ssssssseneneeeeeeneeeenenmeee rer enne nnns 152 Omconfig Convert Non RAID TO RAID missense e eariy et EE e 153 Omconfig Virtual Disk Commands Omconfig Check Consistency QOmcontig CancelCheckConslst riey u ec tree a e a a ees Omconfig Pause Check CorsistelCy sie hd rc e o Deere e dee teen Omconfig Resume Check Conslstencny cnn nana entente nter nnne nenn Omconfig Blink ue EIERE ET Omeontig Unblink Virtual DISK tt tp e e ed p Eh det ue aun Omconfig Initialize Virtual Disk menm emere nennen enne Omconfig Fast Initialize Virtual Disk Omeontig Slow Initialize Virtualize Disk trc the th trie ete indeed Omconfig Cancel Initialize Virtual Disk emen Omconfig Cancel Back
19. Help Command Level 3 Command Level 2 Command Level 1 omconfig storage pdisk vdisk controller enclosure battery globalinfo connector cachecade fluidcache fluidcachepool partition fluidcachedisk The omconfig commands allows you to configure physical disks virtual disks controllers enclosures batteries global information connectors and cachecades To see a list of valid commands for omconfig storage type The following table provides the omconfig storage command syntax Use Sets the storage component properties for which omconfig commands are available Displays the list of omconfig storage pdisk parameters for configuring physical disks Displays the list of omconfig storage vdisk parameters for configuring virtual disks Displays a list of the omconfig storage controller parameters for configuring controllers Displays a list of the omconfig storage controller parameters for configuring enclosures Displays a list of the omconfig storage battery parameters for configuring batteries Displays a list of the omconfig storage globalinfo parameters for configuring global storage properties Displays a list of the omreport storage connector parameters for configuring connectors Displays a list of the omconfig storage cachecade parameters for configuring cachecades Displays the fluid cache properties and the associated fluid cache disks Displays the fluid cache
20. The following table displays the valid parameters for adding system information 126 Table 60 Valid Parameters Of omconfig system assetinfo info system Or omconfig servermodule assetinfo info system Comman Command Comman Name Name Value Pair 2 Description dLevel1 Level 2 d Level3 Value Pair 1 omconfig system or assetinfo info syste location text Location of the system servermodu m le primaryphone lt n gt Phone number of the primary user of the system primaryuser lt user gt Primary user of the system Example Command For Adding System Information To provide a value for a system parameter type a command of the form omconfig system assetinfo info system lt name value pair 2 gt or omconfig servermodule assetinfo info system lt name value pair 2 gt For example type omconfig system assetinfo info system location firstfloor or omconfig servermodule assetinfo info system location firstfloor The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to the same name value pair 1 For an example see Example Command For Adding Acquisition Information Adding Warranty Information Use the omconfig system warranty or omconfig servermodule warranty command to assign values for warranty information A warranty is a contract
21. as follows omconfig system events type fan index 0 severity critical or omconfig servermodul vents type fan index 0 severity critical As a result of the example command Server Administrator sends an SNMP trap only when the first fan in the system chassis index 0 has reached critical fan RPMs Omconfig System Webserver Or Omconfig Servermodule Webserver Use the omconfig system webserver or omconfig servermodule webserver command to start or stop the Web server The following table displays the valid parameters for the command 112 Table 46 Valid Parameters Of Web Server Configuration name value pair Description action start Starts the Web server action stop Stops the Web server action restart Restarts the Web server Omconfig System Recovery Or Omconfig Servermodule Recovery Use the omconfig system recovery or omconfig servermodule recovery command to set the action when the operating system hangs or crashes You can also set the number of seconds that must pass before the system is considered to have a hung operating system The following table lists the valid parameters for the command NOTE The upper and lower limits for the timer are dependent on the system model and configuration Table 47 Valid Parameters Of Omconfig System Recovery Or Omconfig Servermodule Recovery name value pair Description action none Takes no action when the operating system is hung or has crashed action reboot Shuts down the
22. command displays a summary of each component in the system for which events are generated The following table displays the events displayed for various component types NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator Table 14 Valid Parameters Of Omreport System Events Type Or Omreport Servermodule Events Type name value pair Description type accords Reports events for AC power cords type battery Reports events for batteries type fanenclosures Reports events for fan enclosures type fans Reports events for fans type intrusion Reports events for chassis intrusion type log Reports events for logs type memory Reports events for memory type powersupplies Reports events for power supplies type redundancy Reports events for redundancy type systempower Reports events for system power type temps Reports events for temperatures type removableflashmedia Reports events for removable flash media type volts Reports events for voltages The following is an example output Current SNMP Trap Configuration Settings Enable Informational Warning and Critical 49 Disable None Settings Enable Informational Warning and Critical Disable None System Board Fanl RPM Settings Index 0 Enable Informational Warning and Critical Disable None System Board Fan2 RPM Settings Index 1 Enable Informational W
23. disk number For example controller 0 vdisk 1 Omreport Controller Status The following table describes the syntax for the omreport Controller commands Table 67 Omreport Controller Commands Required Command Optional name value pairs Use Levels 1 2 3 omreport storage Displays property information for all controllers controller attached to the system controller id where id is Displays the specified controller and all attached the controller number For components such as enclosures virtual disks example controller 0 physical disks and so on controller id Displays the locked foreign configuration info foreignkeyids information for import or clear operations controller id Displays the empty and occupied slot details of info pdslotreport enclosures in the controller K NOTE This command is not supported on Blackplane SCSI and SWRAID controllers Omreport Enclosure Status The following sections provide the omreport storage enclosure command syntax required to execute the enclosure commands The following table describes the syntax for the omreport Enclosure commands Table 68 Omreport Enclosure Commands Required Command Optional name value pairs Use Levels 1 2 3 omreport storage Displays property information for all enclosure enclosures attached to the system controller id where id is the controller Displays all enclosures connected to number the controller controller id Displays the specified enc
24. dui feet eet iles dus Omconfig Global Enable Smart Thermal Shutdown ssssssssss Omconfig Global Disable Smart Thermal Shbutdown nent Omconfig Global Rescan Controller 1 rrt ite etit e ene ERR Omconfig Set Hot Spare Protection Bolten 186 Omconfig Connector Commands x24 iu icd eret tds parades etos 186 Omeconfig ReScarm Connector ice ct E e e red ente a edet dee ite 186 Omconfig Cach cade Commands iii nt deemed e pte eadein 187 Qmeornfig Blink Cachecade ee eie ete ee eod betta uate ied feed 187 Omconfig Unblink Cachecade AAA 187 Omcorifig Delete Cache ageet EL e te aer d t ee leis 188 Omconfig Resize Cachecade o cet teet iii 188 Omconfig Rename Cachecade sse nnne 188 Omeornfig Pcle SSD Commands sieten e e e e b t vue ds 189 omconfig Add PCle SSD Device ToCachepoo n 189 Omconfig Add PCle SSD Device ToCachepoo nne 189 Omconfig Reactivate PCle SSD Device nennen 189 Omconfig Fluid cache Cormimands sits Ae page ettet etd te dederis 190 Omconfig Applying Or Updating License To The Fluid Cache 190 Omconfig Conecting To The Fluid Cache 190 Omecontig Partition Comrnatnd a onn S ED e eta ad ma eet led 190 Omcontig Refr shing Partition bist ct io de Ee eth 190 Omconfig Fluid Cache Disk Command sessi a i i 191 Omconfig Discarding Data And Disabling Coaching 191 9 Working With CLI Command Results sse 195 Output Options For Command Resuftzs eee eren nene 193 Controlling Co
25. for all temperature probes in the enclosure K NOTE This command is not supported on SCSI RAID controllers omconfig storage enclosure action setalltempprobes controller id enclosure lt ENCLOSUREID gt minwarn n maxwarn n where id is the controller ID The lt ENCLOSUREID gt variable specifies the enclosure In this syntax n is a user specified alphanumeric string Set the thresholds for all temperature probes residing in enclosure 3 attached to connector 2 on controller 1 to 10 and 40 degree Celsius omconfig storage enclosure action setalltempprobes controller 1 enclosure 2 3 minwarn 10 maxwarn 40 Omconfig Reset All Temperature Probe Thresholds Table 112 oOmconfig Reset All Temperature Probe Thresholds Description Syntax Example to Example for SAS controllers Omconfig Blink Resets the minimum and maximum warning temperature thresholds back to their default value for all temperature probes in the enclosure K NOTE This command is not supported on SCSI RAID controllers omconfig storage enclosure action resetalltempprobes controller id enclosure lt ENCLOSUREID gt where idis the controller ID The lt ENCLOSUREID gt variable specifies the enclosure In this syntax n is a user specified alphanumeric string Reset the thresholds for all temperature probes in enclosure 3 attached to connector 2 on controller 1 omconfig storage enclosure action resetalltempprobes con
26. has PXE e enabledwithiscsi Enables the fourth NIC during system boot with iSCSI on if the system has iSCSI on Uses the keypad as number keys off Uses the keypad as arrow keys e enabled Enables Node Interleaving and disables Non Uniform Memory Access e disabled Disables Node Interleaving and enables Non Uniform Memory Access off Disables the parallel port address e pt1 Locates the device on LPT1 e lpt2 Locates the device on LPT2 e lpt3 Locates the device on LPT3 at Sets the parallel port mode to AT e ps2 Sets the parallel port mode to PS 2 e ecp Sets the parallel port mode to ECP extended capabilities port e epp Sets the parallel port mode to EPP enhanced parallel port 73 name value pair 1 attribute attribute primaryscsi attribute romb attribute romba attribute rombb attribute sata attribute sataport 0 7 or a h 74 name value pair 2 setting setting on off force true setting raid off scsi force true setting raid scsi force true setting raid scsi force true setting off ata raid setting off auto Description A CAUTION If you modify the setting for primary scsi romb romba or rombb the system becomes inoperable until you reinstall the operating system on Enables this device e off Disables this device e force true Verification of setting change raid Instructs the BIOS
27. iDRAC is installed Server Administrator displays the Lifecycle Controller version If BMC is installed Server Administrator displays the Unified Server Configurator USC version Omreport Chassis Frontpanel Or Omreport Mainsystem Frontpanel Use the omreport chassis frontpanel or omreport mainsystem frontpanel command to view if the front panel button control settings such as the Power button and or Nonmasking Interrupt NMI button if present on the system are enabled or disabled If the Power button override is present on the system check whether the Power button override is enabled or not If enabled the Power button turns the power to the system On and Off If the NMI button is present on the system check whether the NMI button is enabled or not Use the NMI button to troubleshoot software and device errors when using certain operating systems The Front Panel LCD Security Access displays if the front panel encryption access information is set to View Modify or Disable The Front Panel LCD Information displays information such as service tag remote indication status and so on Omreport Chassis Fru Or Omreport Mainsystem Fru Use the omreport chassis fru or omreport mainsystem fru command to view FRU information When you type omreport chassis fru or omreport mainsystem fru Server Administrator displays a summary of the system s FRU information This information is available in the Server Administrator GUI SNMP
28. of 9600 and 19200 are supported on PowerEdge 1800 1850 2800 and 2850 systems 38400 Sets the volatile and non volatile connection speed to 38400 bits per second 57600 Sets the volatile and non volatile connection speed to 57600 bits per second NOTE Baud rates of 19200 and 57600 are supported on PowerEdge 9G systems 115200 Sets the volatile and non volatile connection speed to 115200 bits per second K NOTE Baud rate of 115200 is supported on certain systems that have a DRAC 5 installed K NOTE Baud rate of 19200 57600 and 115200 are supported on 10G systems that have iDRAC installed administrator Sets the maximum privilege level that are accepted on a serial over LAN channel to Administrator 95 name value pair 1 config config settodefault config terminalmo de config user 96 name value pair 2 deletecontrol outputdel outputbkspspbksp handshakingcontrol enabled disabled inputlinesequence cr null lineediting enabled disabled newlinesequence none crlf null cr lfer lf id number enable true false id number enableserialoverlan true false Description operator Sets the maximum privilege level that are accepted on a serial over LAN channel to Operator user Sets the maximum privilege level that are accepted on a serial over LAN channel to User Takes the default configuration settings utputdel BMC outputs a lt del gt character when l
29. or without PXE iSCSI or ed during system boot ays whether the second NIC is enabled with or without PXE iSCSI or ed during system boot ays whether the third NIC is enabled with or without PXE iSCSI or ed during system boot ays whether the fourth NIC is enabled with or without PXE ISCSI or ed during system boot ays whether TCM is on or off ays whether TPM is off on with pre boot measurements or on without pre boot measurements ays whether the internal USB is enabled or disabled NOTE Server Administrator may not display the USB sequence number if there is only one USB port on the system ays whether the operating system watchdog timer is enabled or disabled ays the status of the probe filter chipset option ays whether the internal SD card is enabled or disabled ays whether the bezel removal intrusion check during system reboot abled or disabled ays whether the BIOS screen is redirected over a particular serial port it is turned off ays whether the diskette is disabled auto enabled or read only ays whether DBS is enabled or disabled on the system ays whether the embedded hypervisor is enabled or disabled ays whether the drive is enabled or disabled ays whether the device is automatically detected and enabled or if the ice is disabled ays whether the device is automatically detected and enabled or if the ice is disabled ays whether the intrusion check is enabled or disa
30. pair 2 setting setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti sett setti setti setti setti setti setti setti setti setti setti setti sett setti setti setti ng Enabled Disabled ng InputOutput Compute ng MaxDataRate 8GTps 7GTps 6GTps ng Enabled Disabled ng Off AtaMode RaidMode AhciMode ng Off Auto ng lt string gt ng lt string gt ng lt string gt ng Off Auto ng lt string gt ng lt string gt ng lt string gt ng Off Auto ng lt string gt ng lt string gt ng lt string gt ing Off Auto ng lt string gt ng lt string gt ng lt string gt ng Off Auto ng lt string gt ng lt string gt ng lt string gt ng Off Auto ng lt string gt ng lt string gt ng lt string gt ing Off Auto ng lt string gt ng lt string gt ng lt string gt Group Serial Communication Slot Disablement System Information System Profile Settings name value pair 1 attribute attribute SataPortG attribute SataPortGCapacity attribute SataPortGDriveType attribute SataPortGModel attribute SataPortH attribute SataPortHCapacity attribute SataPortHDriveType attribute SataPortHModel attribute ConTermType attribute ExtSerialConnector attribute FailSafeBaud attribute RedirAfterBoot attribute SerialComm attribute SerialPortAddress attribute Slot1 attribute Slot2 a
31. pairs Use 1 2 3 omreport storage Displays property information for all cachecade cachecades on all controllers controller id where id is the Displays all cachecades on the controller number For example specified controller controller 0 controller id cachecade id where Displays the specified cachecade on id is the controller number and the the controller cachecade number For example controller 0 cachecade 1 Omreport PCle SSD Status The following table describes the syntax for the omreport pciessd commands 140 Table 78 omreport PCle SSD Command Required Command Levels 1 2 Optional name value pairs Use 3 And name value pair Displays the properties of the PCle SSD subsystem omreport storage pciessd subsystem id Displays the properties of the specified PCle subsystem Omreport Fluid Cache Status The following table describes the syntax for the omreport fluidcache commands Table 79 omreport Fluid Cache Command Required Command Levels 1 2 3 And Use name value pair Displays fluid cache properties and the associated fluid cache disks omreport storage fluidcache Omreport Fluid Cache Pool Status The following table describes the syntax for the omreport fluidcachepool commands Table 80 omreport Fluid Cache Pool Command Required Command Levels 1 2 3 And Use name value pair omreport storage fluidcachepool Displays the properties of the fluid cache pool omreport Partiti
32. pdisk action convertraidtononraid controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller NOTE To convert multiple RAID to non RAID on a given controller use omconfig storage controller action convertraidtononraid command For more information see omconfig Convert Multiple RAID To Non RAID Es Convert RAID to non RAID on physical disk 3 on connector O of controller 1 On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action raidtononraid controller 1 pdisk 0 2 3 Omconfig Convert Non RAID To RAID Description Syntax Example to Example for SAS controllers Converts non RAID to RAID on a physical disk omconfig storage pdisk action convertnonraidtoraid controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller NOTE To convert multiple non RAID to RAID on a given controller use omconfig storage controller actio
33. pool properties Displays the partition details of the specified controller and virtual disk Displays the fluid cache disk properties 145 Omconfig Physical Disk Commands The following sections provide the omconfig command syntax required to execute physical disk tasks Table 85 Omconfig Physical Disk Commands Required Command Levels 1 Optional name value pairs 2 3 omconfig storage pdisk action blink controller id pdisk lt PDISKID gt action unblink controller id pdisk lt PDISKID gt action remove controller id pdisk lt PDISKID gt action instantsecureerase controller id pdisk lt PDISKID gt action cryptographicerase controller id pdisk lt PDISKID gt action initialize controller id pdisk lt PDISKID gt action offline controller id pdisk lt PDISKID gt action online controller id pdisk lt PDISKID gt action assignglobalhotspare controller id pdisk lt PDISKID gt assign lt yes no gt action rebuild controller id pdisk lt PDISKID gt action cancelrebuild controller id pdisk lt PDISKID gt action cancelreplacemember controller id pdisk lt PDISKID gt action clear controller id pdisk lt PDISKID gt action cancelclear controller id pdisk lt PDISKID gt action enabledevicewritecache controller id pdisk lt PDISKID gt action disabledevicewritecache controller id pdisk lt PDISKID gt action exportreliabilitylog controller id pdisk lt PDISKID gt action convertraidtononraid controller id pdisk lt PDISKID gt
34. probe detects a warning event type omconfig system alertaction event currentwarn alert false or omconfig servermodule alertaction event currentwarn alert false To enable broadcast messages if a current probe detects a failure event type omconfig system alertaction event currentfail broadcast true or omconfig servermodule alertaction event currentfail broadcast true Example Fan Probe Actions To generate alerts when a fan probe detects a failure value type omconfig system alertaction event fanfail alert true or omconfig servermodule alertaction event fanfail alert true 106 Example Chassis Intrusion Actions To clear all alert actions for chassis intrusion type omconfig system alertaction event intrusion clearall true or omconfig servermodule alertaction event intrusion clearall true Commands For Clearing Logs You can use the omconfig system or omconfig servermodule command to clear the following logs the alert log command log and hardware or ESM log To clear the contents of the alert log type omconfig system alertlog action clear or omconfig servermodule alertlog action clear NOTE Entering an invalid RAC user name may prevent the command log from displaying Clearing the command log resolves this condition To clear the contents of the command log type omconfig system cmdlog action clear or omconfig servermodule cmdlog action clear To clear the contents o
35. serial connection directterminal Type of messaging that uses printable ASCII characters and allows a limited name value pair 1 name value pair 2 config modembasic modemterminal modembasicterminal privilegelevel administrator Operator user config serialoverlan enable true false baudrate 9600 19200 38400 57600 115200 privilegelevel administrator operator user Description number of text commands over a serial connection directbasicterminal Both basic and terminal mode messaging over a serial connection modembasic Type of messaging used for IPMI messaging over a modem modemterminal Type of messaging that uses printable ASCII characters and allows a limited number of text commands over a modem modembasicterminal Both basic and terminal messaging over a modem K NOTE All commands may not be supported on the system administrator Sets the maximum privilege level that are accepted on a serial connection to Administrator operator Sets the maximum privilege level that are accepted on a serial connection to Operator user Sets the maximum privilege level that are accepted on a serial connection to User true Enables serial over LAN for the BMC false Disables serial over LAN for the BMC 9600 Sets the volatile and nonvolatile connection speed to 9600 bits per second 19200 Sets the volatile and non volatile connection speed to 19200 bits per second NOTE Baud rates
36. short text help for CLI commands The shorthand equivalent of omhelp is the command for which you want help followed by For example to display help for the omreport command type one of the following commands e omhelp omreport omreport The omreport command displays reports of the management information of the system 15 E NOTE For an overall summary of the CLI commands type omhelp E NOTE The omupdate commands are no longer supported in Server Administrator and are replaced by Dell Update Package or the Server Update Utility commands To update the different components download the Dell Update Package and run the package name s f command For more information on the corresponding CLI syntax see the Dell Update Packages for Operating Systems User s Guide or the Dell OpenManage Server Update Utility User s Guide at dell com support manuals Related Links Working With CLI Command Results CLI Error Checking And Error Messages When you type CLI commands the CLI checks these commands for the correct syntax If you type a command and the command is executed successfully a message is displayed stating that the command is successful Success Messages When you type a successful omconfig command data for that component is displayed The following omconfig command examples displays valid CLI commands and their success messages Table 1 Commands And Messages Command Message omconfig chassis temp
37. string gt Type of service that the contract covers vendor lt business Business entity that offers gt service on the system Example Command For Adding Service Information To provide a value for a service parameter type a command of the form omconfig system assetinfo info service lt name value pair 2 gt or omconfig system assetinfo info service lt name value pair 2 gt For example type omconfig system assetinfo info service vendor fixsystemco or omconfig servermodule assetinfo info service vendor fixsystemco The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to the same name value pair 1 For an example see Example Command For Adding Acquisition Information Adding Support Information Support refers to technical assistance that the system user can seek when the user seeks guidance on the proper use of a system to perform tasks The following table displays the valid parameters for adding support information Table 59 Valid Parameters Of omconfig system assetinfo info support Or omconfig servermodule assetinfo info support Comman Command Command Name Name Value Pair 2 Description dLevel1 Level 2 Level 3 Value Pair 1 omconfig system or assetinfo info support automaticfix lt programna Name of any servermodu m
38. supplies default values for all other unspecified parameters For more information on read write and cache policies that are supported by the controller see the Dell OpenManage Online Help Parameter Specification For Creating And Reconfiguring Virtual Disk The following table displays how to specify the omconfig storage controller action createvdisk parameters 167 Table 91 Parameters And Types Parameters Type controller id Required raid lt c r0 r1 ric r5 r6 r10 r50 r60 Required size lt number max min gt Required pdisk lt connector targetID connector targetID Required gt stripesize lt 2k b 4kb 8kb 16kb 32kb 64kb Optional 128kb gt cachepolicy lt d c gt Optional readpolicy lt ra nra ara rc nrc gt Optional writepolicy lt wb wt wc nwc fwb gt Optional name lt string gt Optional spanlength lt n gt parameter Optional controller id parameter Specify the controller ID as reported by the omreport storage controller command For example controller 2 raid lt c rO r1 ric r5 re6 r10 r50 r60 gt Use the raid lt c rO r1 ric r5 r6 r10 r50 r60 gt parameter to specify concatenation or a RAID level for a virtual disk Different controllers support different RAID levels For more information about RAID levels a controller supports and for general information about RAID levels and concatenation see the Dell OpenManage Online Help The fol
39. task on controller 1 omconfig storage controller action stoppatrolread controller 1 K NOTE To stop patrol read the current patrol read mode is set to Manual Omconfig Create Cachecade Descriptio n Syntax Example to Example Creates a cachecade on the given controller omconfig storage controller action createcachecade controller id pdisk PDISKID name lt string gt where idis the controller ID as reported by the omreport storage controller command and PDISKID is specified as pdisk connector enclosureID targetID connector targetID Create a cachecade on controller O omconfig storage controller action createcachecade controller 0 pdisk 0 2 3 name Cachecadel Omconfig Enable LKM Controller Descriptio n Syntax Example to Example Enables the LKM mode and creates the encryption key for the controller omconfig storage controller action enablelkm controller id keyid lt keyid string gt passphrase lt passphrase string gt escrow yes filepath lt Absolute path to the escrow file gt where id is the controller ID as reported by the omreport storage controller command Create the encryption key for the controller omconfig storage controller action enablelkm controller 1 keyid Dell 123 passphrase Dell 123 escrow yes filepath C escrow xml K NOTE If you set escrow yes specify the escrow file path Omconfig Rekey LKM Controller Descriptio n Syntax Example to Exa
40. the first destination Destination1 Example 101 102 103 104 IPv4 address of the first destination 50 Output Destination Configuration Settings Attributes Destination Number Destination 2 Destination Number Destination 5 Destination Number Destination 4 Destination Number Destination 5 Destination Number Destination 6 Destination Number Destination 7 Destination Number Destination 8 attribute communityst ring Description destination 2 Displays the second destination Example 110 120 130 140 Pv4 address of the second destination destination 3 Displays the third destination Example 201 202 203 204 Pv4 address of the third destination destination 4 Displays the fourth destination Example 210 211 212 213 IPv4 address of the fourth destination destination 5 Displays the fifth destination Example 2001 0db8 85a3 0000 0000 8a2e 0370 7334 IPv6 address of the fifth destination destination 6 Displays the sixth destination Example 2001 0db8 85a3 0000 0000 8a2e 0370 7334 IPv6 address of the sixth destination destination 7 Displays the seventh destination Example 210 211 212 213 IP address of the seventh destination destination 8 Displays the eighth destination Example 210 211 212 213 IP address of the eighth destination communitystring Displays the text string that acts as a password and is used to authenticate SNMP messages sent b
41. user or user groups upgraded to administrator or administrator groups cannot configure this alert action setting execapp false Disables the executable application Components And Events For Alert Actions The following table provides the events for which you can set alert actions Components are listed in alphabetical order except that warning events always precede failure events for a component 104 Table 40 Valid Parameters Of Events for Alert Actions Event Name event batterywarn event batteryfail event fanwarn event fanfail event hardwarelogwarn event hardwarelogfull event intrusion event memprefail event memfail event systempeakpower event systempowerwarn event systempowerfail event powersupply event powersupplywarn event processorwarn event processorfail event redundegrad event redunlost event tempwarn event tempfail event voltwarn event voltfail event watchdogasr event removableflashme diapresent event removableflashme diaremoved event removableflashme diafail Description Sets actions when a battery probe detects a warning value Sets actions when a battery probe detects a failure value Sets actions when a fan probe detects a warning value Sets actions when a fan probe detects a failure value Sets actions when a hardware log detects a warning value Sets actions when a hardware log is full Sets actions when a chassis intrusion event is detected Sets actions when a memory probe de
42. you receive another error message Message Error This voltage probe min warning threshold must be between 11 400 and 12 480 Revised command omconfig chassis volts index 3 minwarnthresh 11 500 Message Voltage probe warning threshold s set successfully Scripting And Comparing Using CLI The Server Administrator CLI allows administrators to write batch programs for the operating system For an enterprise with many systems an administrator could write a configuration script that specifies the warning thresholds for each major component of a system and also specifies a set of actions that the administrator wants each system to take in case of a warning or failure event In most critical cases the administrator could write a script so that the system shuts down to prevent damage The administrator could then distribute and execute the script to many managed systems at the same time Such a scenario facilitates configuring any number of new systems acquired by a company and makes implementation of new system administration policies easier across many existing systems that require re configuration A similar scenario is used to populate a large number of newly acquired systems with detailed asset information Much of the information are the same such as the manufacturer or lessor of the system whether support for the system is outsourced name of the company providing insurance for the system method of depreciation and so on Any variable tha
43. 012503 or omconfig servermodule assetinfo info extwarranty enddate 012503 The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to the same name value pair 1 For an example see Example Command For Adding Acquisition Information Adding Lease Information A lease is an agreement to pay for the use of a system for a specified period of time The lessor retains ownership of the system The following table displays the valid parameters for the command Table 54 Valid Parameters Of omconfig system assetinfo info lease Or omconfig servermodule assetinfo info lease Command Command Command Name Name Value Pair 2 Description Level 1 Level 2 Level 3 Value Pair 1 omconfig system or assetinfo info leas buyout amount Amount of money paid servermodule e to purchase a system from a lessor lessor lt lessor gt Business entity that is leasing the system out multischedule true Whether cost of false leasing the system is computed by more than one rate schedule ratefactor lt factor gt Factor used to calculate the lease payment value lt residual gt Fair market value of the system at the end of the lease period 121 Example Command For Adding Lease Information To provide a value for a lease parameter type a command of t
44. 1 and COM port 2 are off or on with or without console redirection Displays whether console redirection after system reboot is enabled or disabled Displays whether the external serial connector is mapped to Serial Device 1 Serial Device 2 or a Remote Access Device Displays the setting for console redirection failsafe baud rate Displays port address for the serial devices BIOS Setup Groups On PowerEdge yx2x Systems The following table lists the available groups of the BIOS setup parameters on PowerEdge yx2x systems K NOTE Based on the hardware configuration the attributes may vary in a specific group Table 6 BIOS Setup Groups On PowerEdge yx2x Systems Group BIOS Boot Settings Boot Settings Description Controls the system boot settings when bootmode is set to bios Controls the system boot settings when bootmode is set to bios 29 Group Description Embedded Server Sets up the Embedded Server Management options Management Integrated Devices Controls the devices integrated on the system board Memory Settings Controls the system memory settings Miscellaneous Settings Controls some miscellaneous system settings One Time Boot Supports one time boot to a specified device Processor Settings Controls the processor s settings of the system SATA Settings Control the embedded SATA ports settings Serial Communication Controls the Serial Communication options Slot Disablement Controls the system slots tha
45. 12 COMO Serial device22 COM1 e comt Sets serial port address to COMI e come2 Sets serial port address to COM2 off Disables serial communication setting on Enables serial communication setting without console redirection e coml Enables serial communication setting with console redirection through COMI e coma Enables serial communication setting with console redirection through COM2 onwithconsole Enables serial communication with console redirection through COM1 and COM2 K NOTE The setting onwithconsole is supported only on Dell blade systems off Disables serial port 1 auto Maps serial port 1 to a COM port e com Maps serial port 1 to COM port 1 e com3 Maps serial port 1 to COM port 3 e bmcserial Maps serial port 1 to BMC Serial e bmcnic Maps serial port 1 to the Baseboard Management Controller BMC NIC rac Maps serial port 1 to the Remote Access Controller RAC 75 name value pair 1 attribute attribute serialport2 attribute speaker attribute cputurbomode attribute uausb attribute usb attribute usbb 76 name value pair 2 setting setting off auto com2 com4 setting on off setting enabled disabled setting on backonly off setting enabled disabled setting enabled enabledwithbios disabled Description e comibmc Maps serial port 1 to COM port 1 bmc NOTE This command is applicable only on
46. C during system boot with iSCSI on if the system has iSCSI enabled Enables the third NIC during system boot enabledwithpxe Enables the third NIC during system boot with PXE on if the system has PXE disabled Disables the third NIC during system boot enabledonly Enables the third NIC during system boot with PXE off if the system has PXE enablednonepxe Enables the third NIC during system boot with PXE off if the system has PXE enabledwithiscsi Enables the third NIC during system boot with iSCSI on if the system has iSCSI name value pair 1 attribute attribute nic4 attribute numlock attribute Nodelnterleave NOTE Use NodeInterleave instead of numa as numa will be deprecated in future releases attribute ppaddress attribute ppmode name value pair 2 setting setting enabled enabledwithpxe disabled enabledonly enablednonepxe enabledwithiscsi setting on off setting enabled disabled setting off lpt1 lpt2 lpt3 setting at ps2 ecp epp Description e enabled Enables the fourth NIC during system boot e enabledwithpxe Enables the fourth NIC during system boot with PXE on if the system has PXE disabled Disables the fourth NIC during system boot enabledonly Enables the fourth NIC during system boot with PXE off if the system has PXE e enablednonepxe Enables the fourth NIC during system boot with PXE off if the system
47. Command Optional name value pairs Levels 1 2 3 omconfig storage action applylicense licensefile lt filename gt fluidcache action connect Omconfig Applying Or Updating License To The Fluid Cache Description Applies or upgrades the fluid cache license Syntax omconfig storage fluidcache action applylicense licensefile lt filename with absolute path gt Example to Apply the fluid cache license Example omconfig storage fluidcache action applylicense licensefile root key licensefile xml Omconfig Conecting To The Fluid Cache Description Connects to the fluid cache system and updates the cache configuration details of the storage subsystem Syntax omconfig storage fluidcache action connect Omconfig Partition Command The following section provide the omconfig command syntax required to execute partition task Table 123 Omconfig Partition Command Required Command Optional name value pairs Levels 1 2 3 omconfig storage partition action refresh Omconfig Refreshing Partition List Description Refreshes the partition list maintained in the storage subsytem Syntax omconfig storage partition action refresh 190 Omconfig Fluid Cache Disk Command The following section provide the omconfig command syntax required to execute the fluid cache disk task Table 124 Omconfig Fluid Cache Disk Command Required Command Optional name value pairs Levels 1 2 3 omconfig storage fluidcachedisk acti
48. Configure the unit in BTU hr percent Configure the unit in percentage maxperformance Sets the processor to the highest supported processor state It offers maximum performance mode with minimal power economy apc Active Power Control apc enables the demand based power management controlled by BIOS osctrl OS Control osctrl enables the demand based name value pair 1 name value pair 2 Description power management controlled by the operating system custom This profile allows you to configure individual BIOS settings It offers added control by displaying the underlying BIOS settings cpupowermode min max min Sets the CPU power systemdbpm osdbpm consumption to minimum max Sets the CPU power consumption to maximum systemdbpm Sets the mode to system demand based power management osdbpm Sets the mode to operating system demand based power management K NOTE These options are applicable only when a custom profile is selected memorypowermode min 800 min Sets the mode to minimum 1067 1333 max power utilization 800 1067 1333 Set the mode to 800 1067 or 1333 MHZ max Sets the mode to maximum performance K NOTE These options are applicable only when a custom profile is selected fanmode min max min Sets the fanmode to minimum power utilization max Sets the fanmode to maximum power utilization NOTE These options are applicable only when a cust
49. Dell OpenManage Server Administrator Version 7 4 Command Line Interface Guide Notes Cautions and Warnings Es NOTE A NOTE indicates important information that helps you make better use of your computer A CAUTION A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem A WARNING A WARNING indicates a potential for property damage personal injury or death Copyright 2014 Dell Inc All rights reserved This product is protected by U S and international copyright and intellectual property laws Dell and the Dell logo are trademarks of Dell Inc in the United States and or other jurisdictions All other marks and names mentioned herein may be trademarks of their respective companies 2014 03 Rev AOO Contents uM Fake gots I cd oa MT CE Tm 11 What s New In This Release tee ete rtt i ien dte t t te etd ttes 11 Accessing The Windows Command Prompt To Run CLI Commande 15 Primary ELCANO statua eret 15 CLI Error Checking And Error Messages 14 Success Messages sse enter ert pa Ote rtp t at be Deed od 14 Failure Messages ciat edat aiam ene eed ate unte eeu estes od bra ge bene a 14 Scripting And Comparing Using LL iier e eae rete ee e Lee dr e Let FU ee 15 Command Syntax Overview a sedes teste eter ebenso diia 15 2 Using The omhelp Commande 17 Exatmple Help Corntnaridszeetrsepe ee SE ee 17 5 omreport Viewing System Status Using The Instrumentation Service
50. Depreciation Information 120 Adding Extended Warranty Information 120 Example Command For Adding Extended Warranty Intormatlon 121 Addindg bease Inforfriatlori ito p it are pa pande HE et eie rediret duda 121 Example Command For Adding Lease Information 122 Adding Maintenance IFfOrrridtlorauss cc ote aa me eH n toe ete Loaded Eran eed 122 Example Command For Adding Maintenance Information 122 Adding Outsource Information 123 Example Command For Adding Outsource Information 123 Adding Owner Information Example Command For Adding Owner Information Adding Service Contract Informations to eie t es cde ode lite o tudin E o leds 124 Example Command For Adding Service Information 125 Adding Support Information sicnt a EGER a alive 125 Example Command For Adding Support Information 126 Adding System Information te er ene rod ent e t ndo eee 126 Example Command For Adding System Information 127 Adding Warranty Information et Heat rice e ne d rd ren pen Pee ce ied 127 Example Command For Adding Warranty Information 128 6 Using The Storage Management Service 129 CLEI Gorrimarid Syritax uat ote ebd ect np e a te e bre imo Perd eed Lena 129 Syntax Of Command Elements beue ibo a EE ed ee au io epoca noe d Lio e de 150 User Privileges For Omreport Storage And Omconfig Storage 131 7 Omreport Storage Commandes sse 133 Omreport Physical Disk Status edel eegenen i eed emia E TR LR EEN 134 omtreport le ENEE EE 134 Omreport Cont
51. E For information on terms used in this document see the Glossary at dell com support manuals What s New In This Release The release highlights of OpenManage Server Administrator are e Added support for the following operating system Microsoft Windows Server 2012 R2 Datacenter Foundation Essentials and Standard editions Novell SUSE Linux Enterprise Server 11 SP3 64 bit Red Hat Enterprise Linux 6 5 64 bit VMware ESXi 5 0 U3 and ESXi 5 1 U2 11 12 VMware vSphere 5 5 Added support for the following browsers Mozilla Firefox 22 and 23 Internet Explorer 11 Safari 6 0 Google Chrome 27 28 and 30 Support for a new license format for Citrix XenServer 6 1 Added support for the following Adapter cards Mellanox ConnectX 3 Dual Port 40 GbE QSFP Network Adapter Mellanox ConnectX 3 Dual Port 10 GbE DA SFP Network Adapter Mellanox ConnectX 3 Dual Port 10 GbE KR Blade Mezzanine Card Emulex OCe14102 UX D Dual Port 10Gb SFP CNA Emulex OCm14102 U3 D Dual Port 10Gb KR Blade Mezz Emulex OCm14102 U2 D Dual Port 10Gb KR Blade NDC Emulex OCm14104 UX D Quad Port 10Gb DA SFP Rack NDC Added support for Dell PERC 9 controllers H730P Adapter on R920 with the following features RAID 10 virtual disk with uneven span Advanced 4K sector hard disk drives T10 Protection Information PI for data integrity K NOTE For more information see the Server
52. O output with the present output because in using the outc option you overwrote the fans txt file Append Command Results To An Existing File Use the outa option when you want to append new command results to data stored in a previously written file For example at 11 00 A M you capture fan probe RPM readings for fan probe O on the system and write the results to a file called fans txt To compare these results with output for the same probe obtained four hours later you can use the outa command to append the new output to fans txt Type omreport chassis fans index 0 outa fans txt or omreport mainsystem fans index 0 outa fans txt Fans txt now reads as follows Index Status Probe Name 0 OK System Board Fan 1 RPM Reading 2380RPM Minimum Warning 600RPM Threshold Maximum Warning 5700RPM Threshold Minimum Failure 500RPM Threshold Maximum Failure 6000RPM Threshold Index 20 Status OK Probe Name System Board Fan 1 RPM Reading 3622RPM Minimum Warning 900RPM Threshold Maximum Warning 3500RPM Threshold 195 Minimum Failure 500RPM Threshold Maximum Failure 6000RPM Threshold You can use a text editor to insert the time that each block of data was captured In comparing the two snapshots for fan probe O you can see that the second report shows several changes The reading of fan RPM has increased by 621 RPM but is still within normal range Someone has raised the
53. OS setup options may disable the system or require you to reinstall the operating system NOTE Reboot the system for the BIOS setup options to take effect NOTE Not all BIOS setup options are available on every system K NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator NOTE When CSIOR Collect System Inventory on Restart is disabled you cannot configure the BIOS settings using omconfig command BIOS Setup Settings On Systems Prior To PowerEdge 12G Systems The following table displays the name value pairs that you can use with omconfig chassis biossetup or omconfig mainsystem biossetup command on systems prior to PowerEdge12G systems Table 21 BIOS Setup Settings on systems prior to PowerEdge 12G systems name value pair 1 attribute name value pair 2 setting Description attribute acpwrrecovery setting off last on off System is turned off last System returns to the previous state e on System is turned on delay random immediate random System is turned on timedelay value with random delay 66 name value pair 1 attribute attribute bezel attribute bootsequence attribute bootmode attribute bootorder attribute hddorder name value pair 2 setting setting enabled disabled setting diskettefirst hdonly devicelist cdromfirst opticaldrive setting uefi
54. Warning e Battery Failure e Chassis Intrusion e Current Probe Warning e Current Probe Failure Fan Warning e Fan Failure e Memory Pre failure e Memory Failure e System Power Probe Warning e System Power Probe Detects a Failure System Peak Power Power Supply Warning Power Supply Failure Degraded Redundancy Lost Redundancy e Temperature Warning e Temperature Failure e Voltage Warning e Voltage Failure e Processor Warning e Processor Failure Hardware Log Warning Hardware Log Full e Watchdog Aer e Storage System Warning Storage System Failure Storage Controller Warning Storage Controller Failure 47 Physical Disk Warning Physical Disk Failure e Virtual Disk Warning e Virtual Disk Failure e Enclosure Warning e Enclosure Failure Storage Controller Battery Warning Storage Controller Battery Failure Removable Flash Media Present Removable Flash Media Removed e Removable Flash Media Failure NOTE Storage Controller Battery Warning and Storage Controller Battery Failure events are not available on blade systems Es NOTE System Power Probe Warning is not applicable to blade systems Omreport System Assetinfo Or Omreport Servermodule Assetinfo Use the omreport system assetinfo or omreport servermodule assetinfo command to see cost of ownership data for the system such as acquisition depreciation and warranty information To set any of these fields use the omc
55. ZA NOTE Power Management features are only available for PowerEdge systems that have hot swappable power supplies and not systems that have a fixed non redundant power supply installed Omreport Chassis Pwrsupplies Or Omreport Mainsystem Pwrsupplies Use the omreport chassis pwrsupplies or omreport mainsystem pwrsupplies command to view properties of the system s power supplies Type omreport chassis pwrsupplies or omreport mainsystem pwrsupplies NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable For each power supply profile in the system the values for the following fields are displayed e Status Location Type e Rated Input Wattage in Watts e Maximum Output Wattage e Online Status Power Monitoring Capable Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess Use the omreport chassis remoteaccess or omreport mainsystem remoteaccess command to view general information on baseboard management controller or integrated Dell remote access controller BMC IDRAC and remote access controller if DRAC is installed Type omreport chassis remoteaccess or omreport mainsystem remoteaccess NOTE To maintain consistency across the commands the output format of this command and the subsequent command levels has changed So you may have to change the user scripts as applicable The output of the omreport chassis remotea
56. abled or disabled Processor CMP Displays the number of cores enabled per processor User accessible USB Ports Displays whether the user accessible USB port is enabled or disabled CPU Virtualization Displays the additional hardware capabilities provided by Virtualization Technology Technology AC Power Recovery Mode Displays the system state when input power is restored after an outage Embedded SATA Controller Displays whether the embedded SATA controller is set to ATA mode RAID mode or is disabled SATA Port 0 Displays the state of SATA port 0 SATA Port 1 Displays the state of SATA port 1 27 Parameter Dual NIC 1 2 Dual NIC 3 4 NIC 1 NIC 2 NIC 5 NIC 4 Trusted Cryptographic Module TCM Trusted Platform Module TPM Security Internal USB Port number Operating System Watchdog Timer HT Assist Internal SD Card Bezel Console Redirection Diskette Demand Based Power Management DBS Embedded Hypervisor IDE IDE Primary Drive O IDE Primary Drive 1 Intrusion Mouse 28 Description Disp Disp Disp Disp Disp Disp Disp Disp Disp Disp sp sp sp sp sp Su Uy Ug O lt sp o 2 Y lt sp el a Y Q sp disab disab disab disab ot ays whether NIC 1 and NIC 2 with PXE iSCSI is enabled or disabled ays whether NIC 3 and NIC 4 with PXE ISCSI is enabled or disabled ays whether the first NIC is enabled with
57. and Common Information Model and is primarily used to support troubleshooting activities Omreport Chassis Hwperformance Or Omreport Mainsystem Hwperformance Use the omreport chassis hwperformance or omreport mainsystem hwperformance command to view the status and cause for the system s performance degradation When you type omreport chassis hwperformance or omreport chassis hwperformance Server Administrator displays a summary of the system s hardware performance degradation information E NOTE This command is applicable only to selected Dell 10G systems that support PMBus Depending on the system s configuration you may notice the following output Hardware Performance Index amp H 51 Probe Name System Board Power Optimized Status Normal Cause N A Omreport Chassis Info Or Omreport Mainsystem Info Use the omreport chassis info or omreport mainsystem info command to see a summary of installed component versions Type omreport chassis info index n or omreport mainsystem info index n The index parameter specifies a chassis number and is optional If you do not specify the index Server Administrator displays summary chassis information for each chassis If you specify the index Server Administrator displays summary information for a specific chassis NOTE If iDRAC is installed Server Administrator displays the Lifecycle Controller version If BMC is installed Server Administrator displays the USC v
58. arning and Critical Disable None Omreport System Operatingsystem Or Omreport Servermodule Operatingsystem Use the omreport system operatingsystem or omreport servermodule operatingsystem command to display information about the operating system Omreport System Pedestinations Or Omreport Servermodule Pedestinations Use the omreport system pedestinations or omreport servermodule pedestinations command to view destinations where alerts are sent for platform events Depending on the number of destinations displayed configure a separate IP address for each destination address Type omreport system pedestinations or omreport servermodule pedestinations The output of the omreport system pedestinations or omreport servermodule pedestinations command lists each of the valid parameters NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable Destination Configuration Settings For The Omreport System Pedestinations Or Omreport Servermodule Pedestinations The actual number of destinations that you can configure on a system using omreport system pedestinations or omreport servermodule pedestinations may differ The following table displays the available settings Table 15 Settings For The Omreport System Pedestinations Or Omreport Servermodule Pedestinations Output Attributes Description Destination List Destination Number destination 1 Displays
59. as reported by the omreport command K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controllerzID to display the IDs for the virtual disks attached to the controller K NOTE In some circumstances you may receive a warning message if this command deletes the system or boot partition You can override this warning by using the force yes parameter In this case the syntax is as follows omconfig storage vdisk action slowinit controller id vdisk id force yes Slow initialize virtual disk 4 on controller 1 omconfig storage vdisk action slowinit controller 1 vdisk 4 Omconfig Cancel Initialize Virtual Disk Description Syntax Cancels the initialization of a virtual disk omconfig storage vdisk action cancelinitialize controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command 157 Example to Example K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controllerzID to display the IDs for the virtual disks attached to the controller Cancels the initialization of virtual disk 4 on controller 1 omconfig storage vdisk action cancelinitialize controller id vdisk id Omconfig Cancel Background Initialize Description Syntax Example to Example Cancels the background initialization process on a vir
60. as the output file you specify or you can keep adding results of commands to a file of the same name Saving Command Results To A File That Is Overwritten Use the outc option when you want to overwrite data stored in previously written files For example at 11 00 A M you capture fan probe RPM readings for fan probe O on the system and write the results to a file called fans txt You type omreport chassis fans index 0 outc fans txt or omreport mainsystem fans index 0 outc fans txt Partial results written to the file are Index Status Probe Name Reading Minimum Warning Threshold Maximum Warning Threshold Minimum Failure Threshold Maximum Failure Threshold Wa OK System Board Fan 1 RPM 2380RPM 600RPM 5700RPM 500RPM 6000RPM Four hours later you repeat the command You have no interest in the 11 00 A M snapshot as written to fans txt You type the same command omreport chassis fans index 0 outc fans txt or omreport mainsystem fans index 0 outc fans txt The 3 00 P M data overwrites the 11 00 A M data in the fans txt file Fans txt now reads as follows Index Status Probe Name Reading Minimum Warning Threshold 194 Wa OK System Board Fan 1 RPM 3001RPM 7OORPM Maximum Warning Threshold 5500RPM Minimum Failure Threshold 500RPM Maximum Failure Threshold 6000RPM You cannot refer to the previous command results to compare the earlier fan probe
61. ash NOTE For the list of supported operating systems and Dell servers see the Dell Systems Software Support Matrix in the required version of OpenManage Software at dell com openmanagemanuals E NOTE CU commands are not supported on systems running the VMware ESXi operating system Accessing The Windows Command Prompt To Run CLI Commands If you are running the Microsoft Windows operating system use the 32 bit command prompt to run a Server Administrator CLI command Access the 32 bit command prompt using one of the following methods e Click Start Programs gt Accessories gt Command Prompt e Click Start Run and type cmd exe K NOTE Do not type command in the Run dialog box to launch a command line window this activates the MS DOS emulator command com which has environment variable limitations that can cause subtle problems with CLI Primary CLI Commands The commands that carry out the functions of Server Administrator are e omconfig e omhelp e omreport The omconfig command writes values that you assign to an object s properties You can specify values for warning thresholds on components or prescribe actions that the system must perform when a certain warning or failure event occurs You can also use the omconfig command to assign specific values to the system s asset information parameters such as the purchase price of the system the system s asset tag or the system s location The omhelp command displays
62. at Type omreport preferences messages attribute format The output that is displayed is as follows Event Message Format enhanced Omreport Preferences Webserver Use the omreport preferences webserver command to view the URL details current key sign algorithm and the JRE details The following table lists the available attributes of omreport preferences webserver 58 Table 17 Valid Parameters Of Omreport Preferences Webserver name value pair Description attribute geturl Reports the URL information of the Web server attribute getsignalgorithm Reports the current Key sign algorithm attribute getjre Displays JRE currently being used attribute getjrelist Displays the Server Administrator supported JRE versions installed in the system Type omreport preferences webserver attribute getjrelist The output that is displayed is as follows Version 1 7 0 05 Bundled Path C Program Files lt x86 gt Dell SysMgt jre Version 1 7 0 03 Path C Program Files lt x86 gt Java jre7 59 60 4 Omconfig Managing Components Using The Instrumentation Service The omconfig command allows you to provide values that define warning events configure alert actions Clear logs and configure system shutdown as well as perform other systems management tasks Examples of omconfig capabilities include e Administrator privilege to clear command alert and hardware logs e Administrator privilege to configu
63. ata and stops the cycle The cache then writes the data back to the main memory when the system bus is available In a write through policy the processor writes through the cache to the main memory The write cycle does not complete until the data is stored into the main memory Associativity Refers to the way in which main memory content is stored on the cache e A fully associative cache allows any line in main memory to store at any location in the cache An way set associative cache directly maps n specific lines of memory to the same n lines of cache For example line O of any page in memory is stored in line 0 of cache memory 38 Field Description Cache Device Supported Type of static random access memory SRAM that the device can Type support Cache Device Current Type Type of the currently installed SRAM that the cache is supporting External Socket Name Silk Name printed on the system board next to the socket Screen Name Error Correction Type Identifies the type of error checking and correction ECC that this memory can perform Examples are correctable ECC or uncorrectable ECC Omreport Chassis Pwrmanagement Or Omreport Mainsystem Pwrmanagement Use the omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command to view the power budget cap and power management profiles of the system The values display either in Watts or BTU Hr based on the configuration Type omreport chassis pwrmanagem
64. between the manufacturer or dealer and the purchaser of a system The warranty identifies the components that are covered for repair or replacement for a specified length of time or usage For details on editing extended warranty values see Adding Extended Warranty Information The following table displays the valid parameters for adding warranty information Table 61 Valid Parameters Of omconfig system assetinfo info warranty Or omconfig servermodule assetinfo info warranty Command Command Command Name Name Value Pair 2 Description Level 1 Level 2 Level 3 Value Pair 1 omconfig system or assetinfo info warrant cost cost Cost of the warranty servermodul y service e duration duration Number of days or months that the warranty is in force 127 Command Command Command Name Name Value Pair 2 Description Level 1 Level 2 Level 3 Value Pair 1 enddate lt enddate gt Date the warranty agreement ends unit days months Whether the number for duration refers to days or months Example Command For Adding Warranty Information To provide a value for a warranty parameter type a command of the form omconfig system assetinfo info warranty lt name value pair 2 gt or omconfig servermodule assetinfo info warranty lt name value pair 2 gt For example type omconfig system assetinfo info warranty unit days or omconfig servermodule assetinfo info warranty unit days The following message is displayed Asset informati
65. bility ng Standard Extended Disabled ng 1x 2x 81 Group System Security UEFI Boot Settings 82 name value pair 1 attribute attribute MemVolt attribute ProcC1E attribute ProcCStates attribute ProcPwrPerf attribute ProcTurboMode attribute SysProfile attribute AcPwrRevry attribute AcPwrRcvryDelay attribute AcPwrRcvryUserDelay attribute AesNi attribute BiosUpdateControl attribute IntelTxt attribute NmiButton attribute PasswordStatus attribute PwrButton attribute SetupPassword attribute SysPassword attribute TcmActivation attribute TcmClear attribute TcmSecurity attribute TpmActivation attribute TpmClear attribute TpmSecurity attribute UefiBootSeq name value pair 2 setting setting AutoVolt Volt15V Volt135V Lr NOTE Volt15V represents 1 5 Volt and Volt155V represents 1 55 Volt setting Enabled Disabled setting Enabled Disabled setting MaxPerf MinPwr SysDbpm OsDbpm setting Enabled Disabled setting PerfPerWattOptimizedOs PerfPerWattOptimizedDapc PerfOptimized Custom DenseCfgOptimized setting On Off Last setting Immediate User Random setting integer setting Enabled Disabled setting Unlocked Limited Locked setting On Off setting Enabled Disabled setting Locked Unlocked setting Enabled Disabled setting string setting string setting NoChange Activate Deactivate A CAUTION Clearing th
66. bled during system ays whether the mouse is enabled or disabled Parameter Optical Drive Controller Parallel port address Parallel port mode Primary SCSI RAID on motherboard RAID Channel A RAID Channel B Serial Port 1 Serial Port 2 Speaker USB or USBB Secondary SCSI Serial Communications Console Redirection After Boot External Serial Connector Console Redirection Failsafe Baud Rate Serial Address Select Description Displays whether the optical drive controller is enabled or disabled Displays whether the address is located on LPT1 LPT2 and LPT3 or if it is disabled Displays the setting associated with the parallel port Displays whether the device is on or off Displays whether RAID on motherboard is detected as a RAID device a SCSI device or if the device is disabled during system boot Displays whether RAID on motherboard Channel A is detected as a RAID device or a SCSI device Displays whether RAID on motherboard Channel B is detected as a RAID device or a SCSI device Displays whether serial port 1 is mapped to a COM port COM port 1 COM port 5 COM1 BMC BMC Serial BMC NIC BMC RAC or is disabled Displays whether serial port 2 is mapped to a COM port COM port 2 COM port 4 or is disabled Displays whether the speaker is on or off Displays whether the USB port is enabled or disabled Displays whether the device is enabled or disabled Displays whether COM port
67. blefluidcache controller id vdisk id devicename lt string gt cachepolicy lt wb wt gt where id is the controller ID and virtual disk ID as reported by the omreport command and string is the device name of the virtual disk wb is writeback and wt is writethrough To obtain the values for controller ID and virtual disk ID type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Enable fluid cache on virtual disk 4 on controller 1 omconfig storage vdisk action enablefluidcache controller 1 vdisk 4 devicename dev sdb cacachepolicy wb Omconfig Disable Fluid Cache on Virtual Disk Description Syntax Example to Example Disables fluid cache for the specified virtual disk omconfig storage vdisk action disablefluidcache controller id vdisk id devicename lt string gt where id is the controller ID and virtual disk ID as reported by the omreportcommand and string is the device name of the virtual disk To obtain the values for controller ID and virtual disk ID type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Disable fluid cache on virtual disk 4 on controller 1 omconfig storage vdisk action disablefluidcache controller 1 vdisk 4 devicename dev sdb Om
68. cal disk 3 on connector O of controller 1 of virtual disk 4 with physical disk 5 On a Serial Attached SCSI SAS controller the physical disk resides in enclosure 2 omconfig storage vdisk action replacememberdisk controller 1 vdisk 4 source 0 3 destination 0 5 omconfig storage vdisk action replacememberdisk controller 1 vdisk 4 source 0 2 3 destination 0 2 5 Omconfig Rename Virtual Disk Description Syntax Renames a virtual disk omconfig storage vdisk action rename controller id vdisk id name lt string gt where id is the controller ID and virtual disk ID as reported by the omreport command and lt string gt is the new name for the virtual disk 161 Example to Example K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controllerzID to display the IDs for the virtual disks attached to the controller Rename virtual disk 4 on controller 1 to vd4 omconfig storage vdisk action rename controller 1 vdisk 4 name vd4 Omconfig Enable Fluid Cache on Virtual Disk Description Syntax Example to Example Enables fluid cache for the specified virtual disk K NOTE Enabling fluid cache creates a new fluid cache disk You must use only the new fluid cache disk for all future data access Data access to any of the corresponding virtual disk or caching its partitions may lead to data corruption omconfig storage vdisk action ena
69. ccess or omreport mainsystem remoteaccess command lists each of the valid parameters as displayed in the following table Table 12 Valid Parameters Of Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess name value pair Description config additional Reports the current state of IPv4 and IPv6 addresses on iDRAC config advsol Reports advanced BMC iDRAC or remote access information on a serial over local area network LAN connection config nic Reports BMC iDRAC or remote access information for the LAN 42 name value pair Description config serial Reports serial port information for BMC or remote access config serialoverla Reports BMC iDRAC or remote access information on a serial over LAN n connection config terminalmo Reports terminal mode settings for the serial port de config user Reports information on BMC iDRAC or remote access users Omreport Chassis Removableflashmedia Or Omreport Mainsystem Removableflashmedia Use the omreport chassis removableflashmedia or omreport mainsystem removableflashmedia to view the removable flash media details on the system along with its health status Type omreport chassis removableflashmedia or omreport mainsystem removableflashmedia Server Administrator displays a summary of the system s removable flash media information Es NOTE If the vFlash or SD card size is less than 1 GB the size is displayed in MB Depending on the configuration of the system y
70. ce Line 1 upon redundancy restoration return to Line 1 AC Power Lines Status Ok Location AC Power Line 1 AC Present t Power Present Active Source Active Status Ok Location AC Power Line 2 AC Present Power Present Active Source Not Active Server Administrator reports values for the Redundancy Status and Redundancy Mode fields Omreport Chassis Batteries Or Omreport Mainsystem Batteries Use the omreport chassis batteries or omreport mainsystem batteries command to view battery properties Type omreport chassis batteries or omreport mainsystem batteries Omreport Chassis Bios Or Omreport Mainsystem Bios Use the omreport chassis bios or omreport mainsystem bios command to view the current BIOS information Type omreport chassis bios or omreport mainsystem bios Server Administrator displays the summary of the BIOS information for the system Omreport Chassis Biossetup Or Omreport Mainsystem Biossetup Use the omreport chassis biossetup or omreport mainsystem biossetup command to view BIOS setup parameters that are normally available only during system boot Type omreport chassis biossetup or omreport mainsystem biossetup 26 NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable To view the BIOS Setup parameters in short form type omreport chassis biossetup display shortnames To view all availabl
71. cefee lt servicefee gt Amount of money charged for service signauth lt name gt Person who signed or authorized the service Example Command For Adding Outsource Information To provide a value for an outsource parameter type a command of the form omconfig system assetinfo info outsource lt name value pair 2 or omconfig servermodule assetinfo info outsource lt name value pair 2 gt For example type omconfig system assetinfo info outsource providerfee 75 or omconfig servermodule assetinfo info outsource providerfee 75 The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to the same name value pair 1 123 For an example see Example Command For Adding Acquisition Information Adding Owner Information The owner is the party that holds legal property title to the system The following table displays the valid parameters for adding owner information Table 57 Valid Parameters Of omconfig system assetinfo info owner Or omconfig servermodule assetinfo info owner Comman Command Comman Name Name Value Pair 2 Description dLevel1 Level 2 dLevel3 Value Pair 1 omconfig system or assetinfo info owne insuranceco company Name of the insurance servermodul r company that insures e the system ownername business Bus
72. channel lanaccesslevel user User with an ID has access privileges of a user for the LAN channel lanaccesslevel none User with an ID does not have access privileges for the LAN channel id user id User ID of the user being configured dracusergroup admin Enables the Administrator user privileges dracusergroup poweruser Enables the Power User privileges dracusergroup guest Enables the Guest user privileges 97 name value pair 1 name value pair 2 config id user id extipmiusergroup admin operator readonly custom none K NOTE extipmiusergroup user group is available only on Dell yxOx blade systems Usage Of Dracusergroup custom Description dracusergroup custom Enables the Custom User privileges NOTE For more information on dracusergroup custom see Usage of Dracusergroup custom dracusergroup none Does not enable user privileges id user id User ID of the user being configured extipmiusergroup admin Enables the Administrator user privileges extipmiusergroup operator Enables the Operator privileges extipmiusergroup readonly Enables the Read Only privileges extipmiusergroup custom Enables the Custom User privileges K NOTE It is recommended that you use the operator and readonly options for systems with iDRAC Enterprise For more information see Usage of Extipmiusergroup custom extipmiusergroupznone Does not enable user privileges The followi
73. cify the escrow file path Omconfig Delete Encryption Key Descriptio Deletes the encryption key for the controller n Syntax Example to Example omconfig storage controller action deletesecuritykey controller id where id is the controller ID as reported by the omreport storage controller command Change the encryption key for the controller omconfig storage controller action deletesecuritykey controller 1 Omconfig Set Background Initialization Rate Descriptio Sets the background initialization rate n Syntax Example to Example omconfig storage controller action setbgirate controller id rate lt 0 to 100 gt where id is the controller ID as reported by the omreport storage controller command Sets the background initialization rate to 50 on controller 1 omconfig storage controller action setbgirate controller 1 rate 50 Omconfig Set Reconstruct Rate Descriptio Sets the reconstruct rate n Syntax omconfig storage controller action setreconstructrate controller id rate lt 0 to 100 gt where id is the controller ID as reported by the omreport storage controller command 175 Example to Example Set the reconstruct rate to 50 on controller 1 omconfig storage controller action setreconstructrate controller 1 rate 50 Omconfig Set Check Consistency Rate Descriptio n Syntax Example to Example Sets the check consistency rate omconfig storage controller action s
74. clear abortcheckconsistencyonerror lt enabled disabled gt loadbalance lt auto disabled gt allowrevertiblehotspareandreplacemember lt enabled disabled gt autoreplacememberonpredictivefailure lt enabled disabled gt persistenthotspare lt enabled disabled gt Enable allow revertible hot spare and replace member operation omconfig storage controller action setchangecontrollerproperties allowrevertiblehotspare andreplacemember enabled controller 1 Omconfig Discard Preserved Cache Descriptio n Syntax Example to Example Discards the preserved cache on the controller K NOTE To check if the controller has a preserved cache type omreport storage controller controller id If the system displays Preserved Cache yes it indicates the presence of the preserved cache omconfig storage controller action discardpreservedcache controller id force enabled disabled If you set force enabled the cache is discarded irrespective of whether the controller detects a foreign or an offline virtual disk Discard the preserved cache omconfig storage controller action discardpreservedcache controller 1 force enabled CAUTION Discarding the preserved cache can result in data loss It is recommended that you run this command using the force disabled option K NOTE If a foreign configuration is detected then the preceding command using force disabled option fails To avoid data loss impo
75. config Reactivate Fluid Cache on Virtual Disk Description Syntax 162 Reactivates the fluid cache for the specified virtual disk omconfig storage vdisk action reactivate controller id vdisk id devicename lt string gt where id is the controller ID and virtual disk ID as reported by the omreportcommand and string is the device name of the virtual disk To obtain the values for controller ID and virtual disk ID type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Example to Reactivate fluid cache on virtual disk 4 on controller 1 Example omconfig storage vdisk action reactivate controller 1 vdisk 4 devicename dev sdb Omconfig Controller Commands The following table provides the omconfig command syntax required to execute controller tasks A CAUTION The omconfig storage controller action resetconfig controller id resets the controller configuration Resetting the controller configuration permanently destroys all data on all virtual disks attached to the controller System or boot partition residing on these virtual disks is destroyed Table 88 Omconfig Controller Commands Required Command Levels Optional name value pairs 1 2 3 omconfig storage action rescan controller id controller action enablealarm controller id action disablealarm controller id action quietalarm controll
76. ct Hate Omconfig Set Check Consistency Rate Omconfig Export The Controller E69 ra Er e e eR ate eee Omconfig Import Secure Foreign Confiouratton eene Omconfig Import Foreign Configuration Omconfig Import Or Recover Foreign Configuration Omconfig Clear Foreign Configuratlon eene nennen nen Omconfig Physical Disk Power Management Omconfig Set PatroU Read MOGS i iter TERR RI n IHR RN Omcontig Start Patrol Read ona o e ce e AEN t e deen lis Omcorfig Stop Patrol Read ce cepere ertet ede pee etate edes Omcontfig Creat Cachecade iae eee tava ai oe ad t dete Le atate da Omconfig Enable LKM Controller cti t lectoras Omconfig Rekey LKM Controller nennen nnne nnt nenne nnne en trennen Omconfig Convert Multiple RAID ToNon RAlD eere Omconfig Convert Multiple Non RAID TobRAal nennen Omconfig Enclosure Command Syiir caba Omconfig Enable Enclosure Alarm Omconfig Disable Enclosure Alamm nennen ener nnne Omconfig Set Enclosure Asset Tag irte tr etit tro p Pe be b ice ee Pee edu Omconfig Set Enclosure Asset Name Omconfig Set Temperature Probe Thresbolds nnne Omconfig Reset Temperature Probe Thresboldes Omconfig Set All Temperature Probe Thresboldes Omconfig Reset All Temperature Probe Threshbolde me lege le Re Omconfig Battery Command cti c sa omconfig Start Battery Learn Cvcle eren nter tinte Omconfig Delay Battery Learn Cycle insane ieee ade eet ete et e dr ete ee eas Orconfig Global Cormoarids 1 1 1o e e end erect fe
77. custo disables logging into e iDRAC K NOTE extipmiusergroup user group is available only on the Dell10G blade systems configureidrac true true or false Enables or false disables configuration of iDRAC Omconfig Chassis Temps Or Omconfig Mainsystem Temps Use the omconfig chassis temps or omconfig mainsystem temps command to set warning thresholds for temperature probes As with other components you can view both warning and failure threshold values but you cannot set failure threshold values The system manufacturer sets the minimum and maximum failure threshold values E NOTE Threshold values that you can set vary from one system configuration to another Valid Parameters For Temperature Warning Thresholds The following table displays the valid parameters for setting temperature warning thresholds Table 33 Valid Parameters For Omconfig Chassis Temps Or Omconfig Mainsystem Temps name value pair Description index lt n gt Number of the probe or probe index specify warnthresh default Sets the minimum and maximum warning threshold values to default minwarnthresh lt n gt Sets the minimum warning threshold values one decimal place maxwarnthresh lt n gt Sets the maximum warning threshold values one decimal place Setting Minimum And Maximum Warning Threshold Values To set both the upper and lower temperature warning threshold values to the recommended default value type omconfig chassis temps index 0 war
78. d NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator Table 48 Valid Parameters Of System Shutdown name value pair action reboot action poweroff action powercycl e osfirst true false Description Shuts down the operating system and initiates system startup performing BIOS checks and reloading the operating system Turns off the electrical power to the system Turns off the electrical power to the system pauses turns the power on and reboots the system Power cycling is useful when you want to re initialize system components such as hard drives true Closes the file system and exits the operating system before shutting down the system false Does not close the file system or shut down the operating system before shutting down the system Example Shutdown Commands To set the shutdown action to reboot type omconfig system shutdown action reboot or omconfig servermodule shutdown action reboot To bypass operating system shutdown before the system is powered off type omconfig system shutdown action reboot osfirst false or omconfig servermodule shutdown action reboot osfirst false Omconfig System Thrmshutdown Or Omconfig Servermodule Thrmshutdown Use the omconfig system thrmshutdown or omconfig servermodule thrmshutdown command to configure a thermal shutdown action Yo
79. d To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller id to display the IDs for the physical disks attached to the controller For example the controller id parameter is specified as controller 1 connector id Indicates the connector ID as reported by the omreport command To obtain this value type omreport storage controller to display the controller IDs and then type omreport storage connector controller idto display the IDs for the connectors attached to the controller For example the connector id parameter is specified as connector 2 vdisk id Indicates the virtual disk ID as reported by the omreport command To obtain this value type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller id to display the IDs for the virtual disks on the controller For example the vdisk id parameter is specified as vdisk 3 enclosure lt ENCLOSUREID gt Indicates a particular enclosure by specifying either enclosure connector or enclosure connector enclosurelD To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage enclosure controller idto display the IDs for the enclosures attached to the controller pdisk lt PDISKID gt Indicates a particular physical disk by specifying either connector targetID or connector enclosurelD targetID To obta
80. disk action blink controller 1 vdisk 4 Omconfig Unblink Virtual Disk Description Syntax Example to Example Unblinks the physical disks included in a virtual disk omconfig storage vdisk action unblink controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the physical disks attached to the controller Unblink the physical disks in virtual disk 4 on controller 1 omconfig storage vdisk action unblink controller 1 vdisk 4 Omconfig Initialize Virtual Disk Description Syntax Example to Example Initializes a virtual disk omconfig storage vdisk action initialize controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Initialize virtual disk 4 on controller 1 omconfig storage vdisk action initialize controller 1 vdisk 4 Omconfig Fast Initialize Virtual Disk Description 156 Fast initializes a virtual disk Syntax Example to Example A CAUTION You may receive a warning message if you attempt to delete t
81. dresses for alert destinations Determines the shutdown action if any taken for a specific platform event Also enables or disables platform events filter alert generation Determines in advance how the system responds to a hung operating system Allows the administrator to select from several options when shutting down the system Sets the severity level at which a thermal event triggers a system shutdown Starts or stops the Web server Configures the behavior of specific system components controlled by the BIOS Configures fan probe warning thresholds to the default or a specific value Es NOTE You cannot change threshold values on embedded server management ESM3 and Dell PowerEdge x8xx systems Configures the Power button Non Masking Interrupt NMI button encryption access and LCD display of the system Allows you to set an initial value or to edit the value of the asset tag or chassis name Specifies when to flash a chassis fault LED or chassis identification LED and allows you to Clear the LED for the system s hard drive Enables or disables the spare bank mirroring raid and Double Device Data Correction 63 Comman Command dLevel1 Level2 storage Command User Use Level 3 Privilege Required DDDC memory modes and also specify which mode to use pwrmanagem P A Allows you to choose between maximum ent power economy and optimized performance of the system pwrmonitorin P A Config
82. drives that are not configured or hot spares that are unattended for 50 minutes omconfig storage controller action setpdiskpwrmanagement spindownunconfigureddrives enabled spindownhotspares enabled spindowntimeinterval 30 controller 1 Omconfig Set Patrol Read Mode Descriptio Sets the patrol read mode for the controller n Syntax Example to Example omconfig storage controller action setpatrolreadmode controller id mode manual auto disable where idis the controller ID as reported by the omreport storage controller command Sets the patrol read on controller 1 to manual mode omconfig storage controller action setpatrolreadmode controller 1 mode manual Omconfig Start Patrol Read Descriptio Starts the patrol read task on the controller n Syntax Example to Example omconfig storage controller action startpatrolread controller id where id is the controller ID as reported by the omreport storage controller command Start the patrol read task on controller 1 omconfig storage controller action startpatrolread controller 1 K NOTE To start patrol read the current patrol read mode is set to Manual Omconfig Stop Patrol Read Descriptio Stops the patrol read task on the controller n Syntax Example to Example 178 omconfig storage controller action stoppatrolread controller id where id is the controller ID as reported by the omreport storage controller command Stop the patrol read
83. e attribute cstates attribute conredirect attribute crab attribute cpucle attribute cpuht attribute cpuvt attribute cpuxdsupport 68 name value pair 2 setting setting enabled disabled setting enabled disabled setting enabled disabled setting enabled disabled setting enabled disabled setting enabled disabled setting enabled disabled Description Es NOTE On Linux systems user or user groups upgraded to administrator or administrator groups cannot configure this BIOS setup setting enabled Enables the processor to go into a deep sleep state when the system is not utilized disabled Disables the processor to go into a deep sleep state when the system is not utilized enabled Redirects the BIOS screen output over serial port 1 Keyboard and text output are redirected over serial port 2 disabled Turns off the BIOS console redirection enabled Enables BIOS console redirection after system reboot disabled Disables BIOS console redirection NOTE The attribute crab is valid for Dell PowerEdge 9G systems only enabled Enables processor C1 E after system reboot disabled Disables processor C1 E after system reboot enabled Enables logical processor hyperthreading disabled Disables logical processor hyperthreading enabled Enables virtualization disabled Disables virtualization enabled Enables Execute Disable XD support on the
84. e TCM will cause loss of all keys in the TCM This could affect booting of the operating system setting Yes No setting On Off setting NoChange Activate Deactivate A CAUTION Clearing the TPM will cause loss of all keys in the TPM This could affect booting of the operating system setting Yes No setting Off OnPbm OnNoPbm sequence aliasnamel aliasname2 aliasnameN Omconfig Chassis Currents Or Omconfig Mainsystem Currents E NOTE This command is no longer available through Server Administrator Omconfig Chassis Fans Or Omconfig Mainsystem Fans Use the omconfig chassis fans or omconfig mainsystem fans command to set fan probe warning thresholds As with other components you can view both warning and failure threshold values but you cannot set failure thresholds The system manufacturer sets the minimum and maximum failure thresholds Valid Parameters For Fan Warning Thresholds The following table shows the valid parameters for setting fan warning thresholds Table 23 omconfig chassis fans or omconfig chassis fans name value pair Description index n Number of the probe or probe index must specify warnthresh default Sets minimum and maximum warning thresholds to default minwarnthresh lt n gt Minimum warning threshold maxwarnthresh lt n gt Maximum warning threshold Default Minimum And Maximum Warning Thresholds NOTE Systems that contain ESM3 ESM4 and BMC capabilities do not a
85. e allotted space for the ESM log is occupied the following caution is displayed Health Non Critical If a caution is displayed resolve all warning and critical severity conditions and then clear the log Omreport System Alertaction Or Omreport Servermodule Alertaction Use the omreport system alertaction or omreport servermodule alertaction command to view a summary of alert actions that have been configured for warning and failure events on the system components 46 Alert actions determine how Server Administrator responds when a component has a warning or failure event The omreport system alertaction or omreport servermodule alertaction command is useful for viewing which alert actions have been specified for components To set an alert action for a component use the omconfig system alertaction or omconfig servermodule alertaction command For more information see omconfig Managing Components Using The Instrumentation Service K NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable K NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator Components And Events Having View Alert Actions View alert action properties for the following components and events if the components or events are present on the system e Battery
86. e boot devices alias names and boot order sequences type omreport chassis biossetup attribute bootorder K NOTE The bootorder attribute is applicable only on systems prior to 12G To list the device boot order type omreport chassis biossetup and serach the list under BIOS Boot Settings or UEFI Boot Settings depending on the BIOS boot setting K NOTE On Linux systems user or user groups upgraded to administrator or administrator groups cannot view the boot order sequence BIOS Setup Parameters On Systems Prior To PowerEdge 12G Systems The following table displays the available BIOS setup parameters on systems prior to PowerEdge 12G systems NOTE All the BIOS Setup parameters are not displayed Only those BIOS setup properties configured during system boot are displayed Table 5 BIOS Setup Parameters On Systems Prior To Dell PowerEdge 12G Systems Parameter Description Bootsequence Displays the device used to boot the system Numlock Displays whether the keypad is used as number keys Embedded Video Displays whether the Embedded Video Controller option is enabled or Controller disabled Boot Mode Displays whether the boot mode is configured to BIOS or Unified Extensible Firmware Interface UEFI Processor C1 E Displays the Processor C1 E status CPU Execute Disable Displays whether the Execute Disable XD option is enabled or disabled Processor C State Control Displays whether the Processor C State Control option is en
87. e controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Unblink physical disk 0 on connector O of controller 1 On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action unblink controller 1 pdisk 0 0 omconfig storage pdisk action unblink controller 1 pdisk 0 2 0 Omconfig Prepare To Remove Physical Disk Table 86 Omconfig Prepare To Remove Physical Disk Description Syntax Prepares a physical disk for removal omconfig storage pdisk action remove controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk Es NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controllerzID to display the IDs for the physical disks attached to the controller 145 Example to Example for SCSI SATA and ATA controllers Example for SAS controllers Prepares physical disk 5 on connector O of controller 1 for removal On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action remove controller 1 pdisk 0 3 omconfig storage pdisk action remove controller 1 pdisk 0 2 3 Omconfig Instant Erase Secured Physical Disk Description Syntax Example to Example for SCSI SATA and ATA controllers Example for SAS controllers Erases the
88. e controller IDs and then type omreport storage cachecade controller ID to display the IDs for the cachecades of the controller Rename cachecade 4 on controller 1 to cc4 Example omconfig storage cachecade action rename controller 1 cachecade 4 name cc4 Omconfig PCle SSD Commands The following table displays the omconfig command syntax required to execute PCle SSD tasks Table 121 omconfig PCle SSD Commands Required Command Levels 1 2 3 omconfig storage pciessd Optional name value pairs action addtocachepool subsystem id pciedevice PDISKID force yes action removefromcachepool subsystem id pciedevice lt PDISKID gt force yes action reactivate subsystem id pciedevice lt PDISKID gt force yes omconfig Add PCle SSD Device To Cachepool Description Syntax Example to Example Adds the specified PCle SSD device to the cache pool omconfig storage pciessd action addtocachepool subsystem id pciedevice lt PDISKID gt where id is the subsystem ID and lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage cachecade controllerzID to display the IDs for the cachecades of the controller Adds the specified PCle SSD device to the cachepool omconfig storage pciessd action addtocachepool subsystem 2 pciedevice 0 2 0 force yes Omconfig Add PCle SSD Device To Cachepool Description Syntax
89. e following table indicates how to specify the diskcachepolicy lt disabled enabled gt parameter for each of the cache policies Table 101 Disk Cache Policy Parameters Disk Cache Policy diskcachepolicy disabled enabled Parameter Specification Disabled diskcachepolicy disabled Enabled diskcachepolicy enabled Readpolicy lt ra nra ara rc nrc gt Different controllers support different read policies The following table displays how to specify the readpolicy lt ra nra ara rc nrc parameter for each of the read policies Table 102 Read Policy Parameters Read Policy readpolicy ra ara nra rc nrc Parameter Specification Read ahead readpolicy ra Adaptive read ahead readpolicy ara No read ahead readpolicy nra Read cache readpolicy rc No read cache readpolicy nrc Writepolicy lt wb wt wc nwc Different controllers support different write policies The following table displays how to specify the writepolicy lt wb wt wc nwc fwb parameter for each of the write policies 172 Table 103 Write Policy Parameters Write Policy writepolicy wb wt wc fwb nwc Parameter Specification Write back cache writepolicy wb Write through cache writepolicy wt Write cache writepolicy wc Force write back writepolicy fwb No write cache writepolicy nwc name lt string gt Use this parameter to specify a name for the virtual disk For example name VirtualDisk1 spanlength lt n
90. e gt application used to fix le a problem automatically helpdesk lt text gt The help desk name or contact information such as a phone number e 125 Comman Command Command Name Name Value Pair 2 Description dLevel1 Level 2 Level 3 Value Pair 1 mail address or website address outsourced true false Whether an external business entity provides technical support or the system owner s employees provide technical support type network storage Whether support is for network attached devices or for storage devices Example Command For Adding Support Information To provide a value for a support parameter type a command of the form omconfig system assetinfo info support lt name value pair 2 gt or omconfig servermodule assetinfo info support lt name value pair 2 gt For example type omconfig system assetinfo info support outsourced true or omconfig servermodule assetinfo info support outsourced true The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to the same name value pair 1 For an example see Example Command For Adding Acquisition Information Adding System Information System information includes the primary user of the system the phone number for the primary user and the location of the system
91. e index Server Administrator displays the Team interface details for the specific NIC and the values for the following fields Team Interface Interface IPv4 Addresses IPv6 Addresses Team Interface Receive Statistics Team Interface Transmit Statistics Interface Receive Statistics and Interface Transmit Statistics Omreport Chassis Ports Or omreport Mainsystem Ports Use the omreport chassis ports or omreport mainsystem ports command to view properties of the system s parallel and serial ports K NOTE CMC USB ports attached with blade servers are not enumerated by OMSA Server Administrator displays values for the following fields Port Type External Name Base I O Address IRQ Level Connector Type and Maximum Speed The following table provides the description of the fields Table 7 Fields and Description Field Description Port Type Detailed type of each system port from the more general serial parallel and USB ports to the names of ports by device type connected to it for example pointing device or keyboard External Name of the port such as serial or parallel USB mouse keyboard and so on Name Base I O Starting I O address expressed in hexadecimal Address IRQ Level Hardware interrupt on a system The hardware interrupt signals the system s CPU that an event has started or ended in a peripheral component such as a modem or printer When communicated over a peripheral component interconnect card the IRQ level
92. e thresholds Valid Parameters For Voltage Warning Thresholds The following table displays the valid parameters for setting voltage warning threshold values K NOTE Threshold values that you can set vary from one system configuration to another Table 34 Valid Parameters Of Omconfig Chassis Volts Or Omconfig Mainsystem Volts name value pair Description index lt n gt Probe index specify warnthresh default Sets minimum and maximum warning threshold values to default minwarnthresh lt n gt Sets minimum warning threshold value three decimal places maxwarnthresh n Sets maximum warning threshold value three decimal places Specify A Value For Minimum And Maximum Warning Thresholds To specify values for the voltage probe warning thresholds you must specify the number of the probe you are configuring and the minimum and or maximum warning threshold values In the following example the probe being configured is probe 0 omconfig chassis volts index 0 minwarnthresh 1 900 maxwarnthresh 2 250 100 or omconfig mainsystem volts index 0 minwarnthresh 1 900 maxwarnthresh 2 250 When you issue the command and the system sets the values you specify the following message is displayed Voltage probe warning threshold s set successfully Omconfig Preferences Use the omconfig preferences command to set system preferences Use the command line to specify the user levels to access Server Administrator and to configure the
93. ear in the command line interface The symbol often called pipe is the logical exclusive or operator For example enable disable means you can enable or disable the component or feature but you cannot simultaneously enable and disable the component or feature 61 omconfig Command Summary The following table provides a high level summary of the omconfig command The columns titled Command level 2 and Command level 5 list the major arguments that are used with omconfig User privilege required refers to the type of privilege you need to run the command where U User P Power User and A Administrator Use is a very general statement about the actions that are performed using omconfig K NOTE Although the following table lists all possible omconfig commands the commands available on the system depend on the system configuration If you try to get help or run a command for a component not installed on the system Server Administrator displays a message that the component or feature is not found on the system K NOTE When CSIOR Collect System Inventory on Restart is disabled omconfig does not allow to configure the BIOS settings Table 19 omconfig Command Level 1 Level 2 and Level 3 Comman Command Command User Use dLevel1 Level2 Level 3 Privilege Required omconfig about U P A Shows the version number and properties for the Server Administrator program details true U P A Displays information for all Server Ad
94. ectrical power to the system action powerreduc Reduces the processor speed until the power consumption comes down and reaches below the warning threshold If the system power consumption stays tion below the warning threshold increases the processor speed K NOTE This action is applicable only for PowerEdge Rack and Tower systems earlier than PowerEdge 11G systems action reboot Forces the operating system to shut down and initiates system startup performs BIOS checks and reloads the operating system 108 Components And Events Of Platform Events The following table lists the components and the events for which you can set platform events Components are listed in alphabetical order except that warning events always precede failure events for a component Table 43 Valid Parameters Of Omconfig System Platformevents Event Name alertsenable true false event batterywarn event batteryfail event discretevolt event fanfail event hardwarelogfail event intrusion event powerwarn event powerabsent event powerfail event processorwarn event processorfail event processorabsent event redundegrad Description true Enables generation of platform event filter alerts false Disables generation of platform event filter alerts K NOTE This setting is independent of the individual platform event filter alert settings For a platform event filter to generate an alert both the individual alert and t
95. edundancy choose among spare mirror raid and DDDC 86 Spare mode disables a bank of system memory in which a correctable memory event is detected enables the spare bank and copies all the data from the original bank to the spare bank Spare bank requires at least three banks of identical memory the operating system does not recognize the spare bank Mirror mode switches to a redundant copy of memory when an uncorrectable memory event is detected After switching to the mirrored memory the system does not switch back to the original system memory until the next reboot The operating system does not recognize half of the installed system memory in this mode RAID mode provides an extra level of memory checking and error recovery at the expense of some memory capacity The DDDC mode enables double device data correction This ensures data availability after hard failure of x4 DRAM NOTE This command is applicable only on systems prior to PowerEdge 12G systems On PowerEdge 12G systems memorymode is grouped under Memory Settings of the BIOS setup group For more information see BIOS Setup Groups on PowerEdge 12G Systems To configure the attribute on systems prior to PowerEdge 12G see the following table The table displays the valid parameters for the command Table 27 Valid Parameters Of Omconfig Chassis Memorymode Or Omconfig Mainsystem Memorymode name value pair 1 Description index lt n gt Number of the chassis where the
96. efault setting When smart thermal shutdown is disabled the operating system and the server shuts down when the PV220S and PV221S enclosures reach a critical temperature of O or 50 degree Celsius Description Disables smart thermal shutdown for all controllers Syntax omconfig storage globalinfo action disablests Example to Disable thermal shutdown The omconfig command syntax for disabling thermal shutdown does not require a controller or enclosure ID K NOTE You can use the omreport storage globalinfo command to determine whether smart thermal shutdown is currently enabled or disabled The status of smart thermal shutdown is also displayed in the GUI of Server Administrator To locate this status select the Storage object and the Information Configuration tab Example omconfig storage globalinfo action disablests 185 Omconfig Global Rescan Controller Description Syntax Example to Example Rescans all the controllers on the system For more information about Global Rescan Controller see the Dell OpenManage Online Help omconfig storage globalinfo action globalrescan Do a global rescan of all controllers The omconfig command syntax for rescanning all controllers on the system does not require a controller or enclosure ID K NOTE Global rescan is not supported on non RAID SCSI and SAS controllers Reboot the system to make visible the configuration changes on non RAID SCSI controllers omconfig storage global
97. em Remoteaccess Omconfig Chassis Temps Or Omconfig Mainsystem Temps Omconfig Chassis Volts Or Omconfig Mainsystem Vote COmcontig Preferentes nct metuit ctra Omconfig Preferences Cdvfomat cnn nano nn nn name ca tenerse nnns Omconftig Preferences DIIServiCe ua dtr C AA Omconfig Preferences Messages Omiconfig Preferences Useraccess jeter codes too atre e RR ni Re cd Omconfig Preferences Webserver Omconfig System Or Omconfig Servermodule Omconfig System Alertaction Or Omconfig Servermodule Alertaction sssss Commands For Clearing LOGS iii e e eo oi dote iere dnce ns Omconfig System Pedestinations Or Omconfig Servermodule Pedestinations 107 Omconfig System Platformevents Or Omconfig Servermodule Platformevents 108 Omconfig System Events Or Omconfig Servermodule Events 110 Omconfig System Webserver Or Omconfig Servermodule Webserver 112 Omconfig System Recovery Or Omconfig Servermodule Recovery sss 115 Omconfig System Shutdown Or Omconfig Servermodule Shbutdowp 115 Omconfig System Thrmshutdown Or Omconfig Servermodule Thrmshutdown 114 5 Omconfig System Or Servermodule Assetinfo Editing Cost Of Ownership Values ne eniti sd 117 Adding Acquisition Information 117 Example Command For Adding Acquisition Information 118 Adding De preciation InformatiQDos scii ici etit eoi ri edente oi unt veo te sona 119 Example Command For Adding
98. emote access lom 4 Configures lom4 port as the primary network for remote access K NOTE The primarynw option is supported from PowerEdge12G systems onward If the primarynw is set to dedicated then set failovernw to none none Configures the failover network to none lom 1 Configures the failover network to lom 1 lom 2 Configures the failover network to lom 2 lom 3 Configures the failover network to lom lom 4 Configures the failover network to lom 4 all Configures the failover network to all loms name value pair 1 name value pair 2 ipaddress P subnet Subnet gateway Gateway ipsource static dhcp systemsoftware ipaddressv6 lt Pv6 address gt prefixlength length gatewayv6 lt value gt ipsourcev6 static auto altdnsserverv6 dnssourcev6 static auto vlanenable true false vlanid number Description K NOTE The failovernw option is supported on PowerEdge12G systems onward Configure both primarynw and failovernw to set the nicselection The primarynw and failovernw options cannot have the same value K NOTE Failovernw requires license to configure the ports If the appropriate license is not installed or has expired the system displays an error message For more information see Dell License Manager at dell com openmanagemanuals Sets the IP address if you have selected static as the IP address source for the BMC LAN interface Sets a subnet mask if yo
99. ent or omreport mainsystem pwrmanagement E NOTE To maintain consistency across the commands the output format of this command and the subsequent command levels has changed So you may have to change the user scripts as applicable E NOTE The omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command is applicable on PowerEdge 11G systems that support Power Management Bus PMBus and that have hot swappable power supplies and not systems that have a fixed non redundant power supply installed The output of the omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command lists each of the valid parameters The following table lists the available settings Table 11 Valid Parameters Of Omreport Chassis Pwrmanagement Or Omreport Mainsystem Pwrmanagement name value pair Description unit watt btuphr gt Displays power in the user specified units config budget Displays power budget information config profile Displays power profiles information K NOTE On PowerEdge 12G systems profile option is SysProfile and is grouped under System Profile Settings of the BIOS setup group For more information see BIOS Setup Settings on PowerEdge 12G systems For each power management profile in the system values display for the following fields Maximum Performance Active Power Controller OS Control and Custom The Custom attributes are CPU Power and Performance Management Memory Power and Perfo
100. er Privilege Required Use Nonmasking Interrupt NMI button if present on the system are enabled or disabled It also displays the front panel encryption access information and the front panel LCD information Displays the Field Replaceable Unit FRU information Displays the status and cause for the system s performance degradation Displays a status summary for main system chassis components Displays the status of the system s intrusion sensor s Displays the properties you have set for light emitting diodes to flash under various alert conditions Displays properties of the system s memory arrays Displays the NIC and Team interface properties Displays the properties for the system s parallel and serial ports such as I O address IRQ level connector type and maximum speed Displays properties of the system s processors including speed manufacturer and processor family Displays power inventory details such as system idle power system maximum potential power and power budget information Displays properties of power consumption Displays the properties of power supplies Displays general information on remote access Displays the properties of the system s expansion slots and other slot types Displays the status and thresholds for the system temperature sensors 21 Command Level 1 22 Command Level Command licenses storage system or servermodule Level 3 v
101. er default 2 Spanlength is an even number and is lesser than or equal to half the number of physical disks specified in size K NOTE The vdpienabled is an optional argument and is valid only on PERC9 controllers If set to yes a T10 Protection Information PI enabled virtual disk is created E NOTE For RAID 10 creation PERC 9 firmware suggests the layout number of array disks with uneven span spans with unequal number of array disks though in a span the number of disks remains even For example for 32 disks RAID 10 gets created with all the disks in one span and for 34 disks RAID 10 gets created with 16 disks in one span and 18 disks in the other span Example Syntax You can create a RAID 5 virtual disk of 500 MB with a stripe size of 16 KB on a PERC 3 QC controller The name of the virtual disk is vd1 and it resides on connector O of controller 1 Because the virtual disk is a RAID 5 it requires at least three physical disks In this example you specify four physical disks These are physical disks O through 3 The virtual disk has read ahead write through caching and cache I O policies To create a virtual disk omconfig storage controller action createvdisk controller 1 raid r5 size 500m pdisk 0 0 0 1 0 2 0 3 stripesize 16kb cachepolicy c readpolicy ra writepolicy wt The only parameters that require specification are for the controller RAID level virtual disk size and physical disk selection Storage Management
102. er id action testalarm controller id action resetconfig controller id force yes action createvdisk controller id raid lt c rO r1 ric r5 r6 r10 r50 r60 size number b m g max min pdisk lt PDISKID gt stripesize lt 2kb 4kb 8kb 16kb 32kb 64kb 128kb 256kb 512kb 1mb gt cachepolicy lt d c gt readpolicy lt ra nra ara rc nrc gt writepolicy lt wb wt wc nwc fwb diskcachepolicy disabled enabled gt name lt string gt spanlength lt n gt secureflag yes vdpienabled yes NOTE For RAID 10 on SAS controllers with firmware version 6 1 and later spanlength is an optional parameter default 2 action setrebuildrate controller id rate lt 0 to 100 gt action setchangecontrollerproperties controller lt id gt bgirate lt rate gt reconstructrate lt rate gt checkconsistencyrate lt rate gt rebuildrate lt rate gt clearredundantpath clear abortcheckconsistencyonerror lt enabled disabled gt loadbalance lt auto disabled gt allowrevertibilehotspareandreplacemember enabled disabled autoreplacememberonpredictivefailure lt enabled disabled gt persistenthotspare enabled disabled rate lt 0 to 100 gt action discardpreservedcache controller id force lt enabled disabled gt action createsecuritykey controller id keyid lt keyid gt passphrase lt passphrase string lescrow yes filepath lt Absolute path to the escrow file gt
103. ersion Depending on the system s configuration you may notice the following output Index EU Chassis Name Main System Chassis Host Name WIN 27C02U0FV6L iDRAC7 Version a 10 0 Chassis Model PowerEdge R720 Chassis Lock Present Chassis Service Tag 7654321 Express Service Cod 15608862073 Chassis Asset Tag LoG Omreport Chassis Intrusion Use the omreport chassis intrusion command to find out whether the cover of the system is open or not Server Administrator tracks chassis intrusion events because intrusions may indicate an attempt to steal a system component or to perform unauthorized maintenance on the system Type omreport chassis intrusion A message that resembles the following is displayed Intrusion Information Health 2 Ok Index so Status OK 32 Probe Name Intrusion State Chassis is closed Omreport Chassis Leds Or Omreport Mainsystem Leds Use the omreport chassis leds or omreport mainsystem leds command to find out whether clear hard drive fault is supported and what severity level lights up the LED Type omreport chassis leds index n or omreport mainsystem leds index n The index parameter is optional If you do not specify the index Server Administrator displays a summary of LED information for chassis 0 If you specify the index Server Administrator displays a summary for a specific chassis The following is an example output Main System Chassis Flash c
104. etcheckconsistencyrate controller id rate lt 0 to 100 where idis the controller ID as reported by the omreport storage controller command Sets the check consistency rate to 50 on controller 1 omconfig storage controller action setcheckconsistencyrate controller 1 rate 50 Omconfig Export The Controller Log Descriptio n Syntax Example to Example Exports the controller log to a text file For more information about the exported log file see the Dell OpenManage Online Help omconfig storage controller action exportlog controller id where idis the controller ID as reported by the omreport storage controller command Export the log on controller 1 omconfig storage controller action exportlog controller 1 By default the log file is exported to C WINNT or C Windows on Microsoft Windows systems based on the Windows version used and var logon all Linux systems Depending on the controller the log file name is afa mmad log or lsi_ lt mmdd gt log where lt mmdd gt is the month and date For more information on the controller log file see the Dell OpenManage Online Help K NOTE The export log file command is not supported on the 4 IM CERC ATA and 100 4ch controllers Omconfig Import Secure Foreign Configuration Descriptio n Syntax Example to Example 176 Unlocks the encrypted Local Key Management LKM foreign configuration drives omconfig storage controller action importsecuref
105. ets the console redirection failsafe baud rate to 9600 bits per second name value pair 1 attribute attribute htassist attribute ide attribute idepridrv attribute intrusion attribute intusbl1 2 K NOTE The following option is deprecated attribute intusb attribute mouse attribute nic1 name value pair 2 setting setting enabled disabled setting on off force true setting off auto setting enabled disabled setting enabled disabled setting on off setting enabled enabledwithpxe disabled enabledonly enablednonepxe enabledwithiscsi Description e 19200 Sets the console redirection failsafe baud rate to 19200 bits per second e 57600 Sets the console redirection failsafe baud rate to 57600 bits per second e 115200 Sets the console redirection failsafe baud rate to 115200 bits per second e enabled Enables the probe filter chipset option e disabled Disables the probe filter chipset option K NOTE Certain applications do not function fully if you enable or disable this option on Enables IDE e off Disables IDE e force true Verification of setting change e off Disables the device e auto Detects and enables the device automatically e enabled Enables the intrusion check during system boot If the system also has bezel intrusion checking then the intrusion option checks for removal of the bezel of the system disabled Disab
106. etween the BMC and the destination management station NOTE On 12G systems with iDRAC7 specific versions ipaddress can also be a Fully Qualified Domain Name FQDN Omreport System Platformevents Or Omreport Servermodule Platformevents Use the omreport system platformevents or omreport servermodule platformevents command to view how the system responds for each listed platform event 51 NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable Omreport System Recovery Or Omreport Servermodule Recovery Use the omreport system recovery or omreport servermodule recovery command to see whether there is an action configured for a hung operating system You can also view the number of seconds that must elapse before an operating system is considered hung Omreport System Shutdown Or Omreport Servermodule Shutdown Use the omreport system shutdown or omreport servermodule shutdown command to view any pending shutdown actions for the system If properties for shutdown are configured executing this command displays these properties NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator Omreport System Summary Or Omreport Servermodule Summary Use the omreport system summary or omreport servermodule summarycommand to view a comprehensive s
107. f the ESM log type omconfig system esmlog action clear or omconfig servermodule esmlog action clear NOTE For more information about alert messages see the Dell OpenManage Server Administrator Messages Reference Guide at dell com support manuals Omconfig System Pedestinations Or Omconfig Servermodule Pedestinations Use the omconfig system pedestinations or omconfig servermodule pedestinations command to set IP addresses for alert destinations The following table displays the valid parameters for the command E NOTE You can either specify the index and IP address as parameters together or you can set only the community string as a parameter Es NOTE Index 1 to 4 accepts an IPv4 address and index 5 to 8 accepts an IPv6 address On 12G systems with iDRAC7 specific versions the index can accept IPv4 IPv6 or FQDN Table 41 Valid Parameters Of Omconfig System Pedestinations Or Omconfig Servermodule Pedestinations name Value Pair Description destenable true false true Enables an individual platform event filter destination after a valid IP address has been set 107 name Value Pair Description false Disables an individual platform event filter index number Sets the index for the destination ipaddress ipv4 address Sets the IP address for the destination ipv6 address fqdn gt Es NOTE On 12G systems with iDRAC7 specific versions ipaddress can also be a Fully Qualified Domain Name FQDN commun
108. formatting option is required because list format is the default display format The network data part of the example system summary is displayed as follows Network Interface O0 IP Address 143 166 152 108 Subnet Mask Z 299729972990 Default Gateway E r MAC Address 00 02 b3 23 d2 ca Table tbl Use the tbl or table formatting option to have the data formatted in table rows and columns To see the following example command output in table format type omreport system summary fmt tbl or omreport servermodule summary fmt tbl The example output displays as follows ATTRIBUTE VALUE IP Address 143 166 152 108 Subnet Mask 255255725500 Default Gateway 143 166 152 1 MAC Address 00 02 b3 23 d2 ca Semicolon Separated Values ssv Use the ssv formatting option to deliver output formatted in semicolon separated value format This format also allows you to import the command output results into a spreadsheet program such as Microsoft Excel or into a database program To see the following example command output in semicolon separated value format type omreport system summary fmt ssv or omreport servermodule summary fmt ssv The example output displays as follows Network Interface 0 IP Address 143 166 152 108 Subnet Mask 255 255 255 0 Default Gateway 143 166 152 1 MAC Address 00 02 b3 23 d2 ca 197 Custom Delimited Format cdv Use the cdv formatting option to report expor
109. forms when a removable flash media fails Sets action or enables or disables alert generation when a temperature probe detects that the temperature is either too high or low for proper operation Sets action or enables or disables alert generation when a voltage probe detects that the voltage is too low for proper operation Sets actions that Server Administrator performs when an internal dual SD card critical event occurs Sets actions that Server Administrator performs when an internal dual SD card warning is displayed Sets actions that Server Administrator performs when an internal dual SD card is not available Sets actions that Server Administrator performs when the redundancy of an internal dual SD card is lost Enables or disables alert generation configured by the ASR when the system has hung or is not responding Omconfig System Events Or Omconfig Servermodule Events Use the omconfig system events or omconfig servermodule events command to enable and disable SNMP traps for the components on your system K NOTE Not all event types are present on the system There are four parameters in the name value pair component of the omconfig system events command Source e Type Severity 110 e Index Source At present source snmptraps is a required name value pair because SNMP is currently the only supported source of event notification for the system s components omconfig system events source sn
110. g Chassis Info Or Omconfig Mainsystem Info name value pair index lt n gt tag lt text gt name lt text gt Description Number of the chassis whose asset tag or name you are setting Asset tag in the form of alphanumeric text Letters or numbers should not exceed 10 characters Name of the chassis In the following example the asset tag for the main system chassis is being set to buildsys omconfig chassis info index 0 tag buildsys 85 or omconfig mainsystem info index 0 tag buildsys Index O always defaults to the main system chassis The following command omits index n but accomplishes the same omconfig chassis info tag buildsys or omconfig mainsystem info tag buildsys An acceptable command when executed results in the following message Chassis info set successfully For some chassis you can assign a different name You cannot rename the main system chassis In the following example the command renames chassis 2 from storscsil to storscsia omconfig chassis info index 2 name storscsia or omconfig mainsystem info index 2 name storscsia As with other commands the CLI issues an error message if you do not have a chassis 2 the main chassis 0 The CLI allows you to issue commands only for the system configuration you have Omconfig Chassis Leds Or Omconfig Mainsystem Leds Use the omconfig chassis leds or omconfig mainsystem leds command to specify when to flash a chassis fault LED or chass
111. g a controller rescan Syntax Example to Example K NOTE This command is not supported on SAS controllers omconfig storage connector action rescan controller id connector id where id is the controller ID and the connector ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage connector controller ID to display the IDs for the connectors attached to the controller Rescan connector 2 on controller 1 omconfig storage connector action rescan controller 1 connector 2 Omconfig Cachecade Commands The following table displays the omconfig command syntax required to execute cachecade tasks Table 120 omconfig Cachecade Commands Required Command Levels 1 2 3 omconfig storage cachecade Optional name value pairs action blink controller id cachecade id action unblink controller id cachecade id action deletecachecade controller id cachecade id force yes action resize controller id cachecade id pdisk lt PDISKID gt action rename controller id cachecade id name lt string gt Omconfig Blink Cachecade Description Syntax Example to Example Blinks the physical disks included in a cachecade omconfig storage cachecade action blink controller id cachecade id where id is the controller ID and the cachecade ID as reported by the omreport command To obtain these values type omreport storage controller
112. given encrypted disk K NOTE This command is applicable only on Micron devices omconfig storage pdisk action instantsecureerase controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Erase physical disk 5 on connector 0 of controller 1 On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action instantsecureerase controller 1 pdisk 0 3 omconfig storage pdisk action instantsecureerase controller 1 pdisk 0 2 3 Omconfig Cryptographic Erase Secured Physical Disk Description Syntax Example to 146 Erases the given encrypted disk K NOTE This command is applicable only on Non Volatile Memory Express NVMe devices omconfig storage pdisk action cryptographicerase controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Erase physical disk 5 on connector 0 of controller 1 On a SAS controller the physical di
113. ground Inttlalze eene Omconfig Assign Dedicated Hot Spare Omcontig Delete VirtUal DISK n cipe ai Omconfig Format Virtual Disk Omconfig Reconfiguring Virtual Disks sse eee nemen Omconfig secure Virtual Disks atii ert db Omconfig Clear Virtual Disk Bad Blocks emen Omconfig Change Virtual Disk Policy ente de tne inb ndo ect dedi e aia Omconfig Replace Member Virtual Disk eem emnes Omconfig Renarne Virtual DISK 5 eei inet Hd nnde ederent Omconfig Enable Fluid Cache on Virtual Disk emen Omconfig Disable Fluid Cache on Virtual Disk Omconfig Reactivate Fluid Cache on Virtual Disk Omconfig Controller Commards err tt Omcontig Rescan Controller ido asa eo epe ea at e a Ooh eo duet Omconftig Eriable Controller Alarma us acct oed ere re tet ed beds Omconfig Disable Controller Alarm Omecontig Quiet Controler Ala Menn eree c pe e a e pat omconfig Test Controller Al rrn 5 dee ENEE EAR EAR i TE dE Omconfig Reset Controller Confiouration nennen omconfig Cr ate Virtual Disk epar e rn de a tI be SEN Omconfig Set Controller Rebuild Rate omconfig Change Controller Droperties ener eene Omeconfig Discard Preserved Cache uid pln heec Macias oe eq ed sean e Omconfig Create Encryption Key Omconfig Change Encryption Key eie eec e eh d Aet er et n de dee dus Omconfig Delete Encryption Key cii etie cp p RO ER E RE ORE FREE Omconfig Set Background Initialization Rate eee Omconfig Set Reconstru
114. gt Required For RAID 50 And RAID 60 And Optional For RAID 10 Use this parameter to specify the number of physical disks in each stripe This parameter applies only to RAID 50 virtual disks If you are not creating a RAID 50 virtual disk do not specify this parameter For example spanlength 3 For RAID 10 on SAS controllers with firmware version 6 1 and later spanlength is optional Also you can now specify the spanlength as an even number with a maximum of 8 spans with 32 physical disks each For example omconfig storage controller action createvdisk controller 1 raid r10 size min pdisk 171242041 T l 1251 23 1 21 4 1 126 EE 21 9 Spanlength 4 Omconfig Set Controller Rebuild Rate Descriptio Sets the controller rebuild rate n Syntax omconfig storage controller action setrebuildrate controller id rate 0 to 100 where idis the controller ID as reported by the omreport storage controller command Example Set the rebuild rate to 50 on controller 1 to Example omconfig storage controller action setrebuildrate controller 1 rate 50 omconfig Change Controller Properties Table 104 omconfig Change Controller Properties Description Changes any or all of the controller properties Syntax omconfig storage controller action setchangecontrollerproperties controller id bgirate rate reconstructrate rate checkconsistencyrate rate 175 Example to Example rebuildrate lt rate gt clearredundantpath
115. hassis identify LED state Off Flash chassis identify LED timeout value 300 Omreport Chassis Memory Or Omreport Mainsystem Memory Use the omreport chassis memory or omreport mainsystem memory to view details for each memory module slot in the system If the system supports redundant memory this command also displays the status state and type of memory redundancy implemented on the system Type omreport chassis memory index n or omreport mainsystem index n The index parameter is optional If you do not specify the index Server Administrator displays information for all memory modules on the system as follows The following is an example output Memory Information Health Ok Attributes of Memory Array s Location System Board or Motherboard Use System memory Installed Capacity 65536 MB Maximum Capacity 786432 MB Slots Available ZA Slots Used 8 33 Error Correction Total of Memory Array s otal Installed Capacity Total Installed Capacity Available to the OS otal Maximum Capacity Details of Memory Array 1 Index Status Status Status Connector Name Type Size Index Status Connector Name Type Size Index Status Connector Name Type Size Index Status Connector Name Type Size 34 Multibit ECC 65536 MB 64386 MB 786432 MB 0 Ok Ok Ok DIMM Al DDR3 Synchronous Registered Buffered 8192 MB 1 Ok DIMM A2
116. he form omconfig system assetinfo info lease lt name value pair 2 or omconfig servermodule assetinfo info lease lt name value pair 2 For example type omconfig system assetinfo info lease value 4500 or omconfig servermodule assetinfo info lease value 4500 The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfocommand at the same time as long as all the parameters for name value pair 2 belong to the same name value pair 1 For an example see Example Command For Adding Acquisition Information Adding Maintenance Information Maintenance refers to activities required to keep the system in good working order The following table displays the valid parameters for adding maintenance information Table 55 Valid Parameters Of omconfig system assetinfo info maintenance Or omconfig servermodule assetinfo info maintenance Command Command Command Name Value Name Value Pair Description Level 1 Level 2 Level 3 Pair 1 omconfig system or assetinfo info mainten enddate lt enddate Date the extended servermodule ance gt warranty agreement ends provider lt provider Business entity gt providing the maintenance service startdate lt startdat Date the e gt maintenance begins restrictions lt string Activities not covered gt by the maintenance contract Example Command For Adding Maintenance Information To p
117. he global event alert are enabled Sets act ion or enables or disab device detects that the battery Sets act ion or enables or disab device detects that the battery Sets act voltage Sets act ion or enables or disab probe detects that the ion or enables or disab es alert generation when a battery is pending a failure condition es alert generation when a battery has failed es alert generation when a discrete voltage is too low for proper operation es alert generation when a fan probe detects that the fan is running too slow or not at all Enables or disables alert generation when a hardware log detects a failure value Sets action or enables or disables alert generation when a chassis is opened Sets action or enables or disables alert generation when a power device probe detects that the power supply voltage regulator module or DC to DC converter is pending a failure condition Sets action or enables or disables alert generation when a processor probe detects that the power supply is absent Sets action or enables or disables alert generation when a power device probe detects that the power supply voltage regulator module or DC to DC converter has failed Sets action or enables or disables alert generation when a processor probe detects that the processor is running at less than peak performance or speed Sets action or enables or disables alert generation when a processor probe de
118. he parameters are listed in alphabetical order instead of the order in which they appear in the command line interface The symbol often called pipe is the logical exclusive or operator For example enable disable means you can enable or disable the component or feature but you cannot simultaneously enable and disable the component or feature 19 Command Summary Of The omreport Command Depending on the system configuration the results of the omreport command vary from one system to another Data displays for installed components only NOTE When a system includes an external chassis the displayed results vary by operating system On SUSE Linux Enterprise Server and Red Hat Enterprise Linux systems the omreport commands display external chassis information in a separate section after the main chassis information On Microsoft Windows systems data about the external chassis does not appear in the omreport output The following table provides a high level summary of the omreport command The column titled Command level 1 displays the omreport command at its most general use Command level 2 shows the major objects or components that you can view using omreport about chassis storage and system Command level 3 lists the specific objects and components to view reports User privilege required refers to the type of privilege you need to run the command where U User P Power User and A Administrator Use is a very general state
119. he processor Version Current Speed Actual processor speed in MHz at system boot time State Whether the processor slot is enabled or disabled Core Count Number of processors integrated into one chip Capabilities And Cache Properties Of A Specific Processor To view the cache properties of a processor on a given connector type omreport chassis processors index n or omreport mainsystem processors index n The index parameter is optional If you do not specify the index Server Administrator displays properties for all processors If you specify the index Server Administrator displays properties for a specific processor The following table lists the fields that are defined for the capabilities present on a particular microprocessor Table 9 Microprocessors and Fields Microprocessor Fields Intel Processor e 64 bit Support e Hyperthreading HT e Virtualization Technology VT e Demand Based Switching DBS e Execute Disable XD Turbo Mode AMD Processor 64 bit Support e AMD V AMD PowerNow No Execute NX 57 The following fields are defined for a cache present on a particular microprocessor If the cache is internal to the processor the fields do not appear in the cache report Speed Cache Device Supported Type Cache Device Current Type External Socket Name NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of Ope
120. he system or boot partition However this warning message is not generated always Ensure that you do not delete the system or boot partition or other vital data when using this command omconfig storage vdisk action fastinit controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controllerzID to display the IDs for the virtual disks attached to the controller K NOTE In some circumstances you may receive a warning message if this command deletes the system or boot partition You can override this warning by using the force yes parameter In this case the syntax is as follows omconfig storage vdisk action fastinit controller id vdisk id force yes Fast initialize virtual disk 4 on controller 1 omconfig storage vdisk action fastinit controller 1 vdisk 4 Omconfig Slow Initialize Virtualize Disk Description Syntax Example to Example Slow initializes a virtual disk A CAUTION You may receive a warning message if you attempt to delete the system or boot partition However this warning message is not generated always Ensure that you do not delete the system or boot partition or other vital data when using this command omconfig storage vdisk action slowinit controller id vdisk id where id is the controller ID and virtual disk ID
121. igndedicatedhotspare controller 1 vdisk 4 pdisk 0 3 assign yes omconfig storage vdisk action assigndedicatedhotspare controller 1 vdisk 4 pdisk 0 2 3 assign yes Omconfig Delete Virtual Disk Description 158 Deletes a virtual disk Syntax Example to Example A CAUTION Deleting a virtual disk destroys all information including file systems and volumes residing on the virtual disk You may receive a warning message if you attempt to delete the system or boot partition However this warning message is not generated always Ensure that you do not delete the system or boot partition or other vital data when using this command omconfig storage vdisk action deletevdisk controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controllerzID to display the IDs for the virtual disks attached to the controller K NOTE In some circumstances you may receive a warning message if this command deletes the system or boot partition You can override this warning by using the force yes parameter In this case the syntax is as follows omconfig storage vdisk action deletevdisk controller id vdisk id force yes Delete virtual disk 4 on controller 1 omconfig storage vdisk action deletevdisk controller 1 vdisk 4 Omconfig Format Virtual Disk Desc
122. iguration Descriptio n Syntax Example to Example Clears or deletes all virtual disks that reside on physical disks newly attached to the controller omconfig storage controller action clearforeignconfig controller id where id is the controller ID as reported by the omreport storage controller command K NOTE This command is supported only in firmware version 5 0 x Clear foreign configurations on controller 1 omconfig storage controller action clearforeignconfig controller 1 Omconfig Physical Disk Power Management Descriptio n Syntax Manages the power of physical disks in a controller by spinning down hot spares configured drives and unconfigured drives omconfig storage controller action setpdiskpwrmanagement spindownunconfigureddrives lt enabled disabled gt spindownhotspares lt enabled disabled gt spindownconfigureddrives lt enabled disabled gt idlec lt enabled disabled gt spindowntimeinterval lt 30 to 1440 gt minutes 177 Example to Example spinupstarttime lt HH MM AM PM gt spinuptimeinterval 1 to 24 hours where idis the controller ID as reported by the omreport storage controller command K NOTE On PERC 7 controllers only spindownunconfigureddrives spindownhotspares and spindowntimeinterval parameters are supported K NOTE You can specify spinupstarttime and spinuptimeinterval only when you set spindownconfigureddrives enabled Spin down
123. in the values for the connector enclosure and physical disk targetID type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller id to display the IDs for the physical disks attached to the controller battery id Indicates the battery ID as reported by the omreport command To obtain this value type omreport storage controller to display the controller IDs and then type omreport storage battery controller id to display the ID for the controller battery lt gt The caret symbols lt gt enclose variable elements that you must specify 130 Syntax Description For example the namez string parameter is specified as name VirtualDisk1 The bracket symbols indicate optional elements that you can choose whether or not to specify For example when creating a virtual disk the name lt string gt parameter indicates that you have the option of specifying the virtual disk name If you omit this parameter from the syntax then a default name for the virtual disk is chosen for you The pipe symbol separates two or more options from which only one is selected For example when creating a virtual disk the cachepolicy d c indicates that the cache policy is specified as either cachepolicy d or cachepolicy c User Privileges For Omreport Storage And Omconfig Storage Storage Management requires Administrator privileges to use the omconfig storage command Use
124. iness entity that owns the system type owned leased Whether the user of rented the system owns leases or rents the system Example Command For Adding Owner Information To provide a value for an owner parameter type a command of the form omconfig system assetinfo info owner lt name value pair 2 or omconfig servermodule assetinfo info owner lt name value pair 2 gt For example type omconfig system assetinfo info owner type rented or omconfig servermodule assetinfo info owner type rented The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to the same name value pair 1 For an example see Example Command For Adding Acquisition Information Adding Service Contract Information A service contract is an agreement that specifies fees for preventive maintenance and repair of the system The following table displays the valid parameters for adding contract information 124 Table 58 Valid Parameters Of omconfig system assetinfo info service Or omconfig servermodule assetinfo info service Comman Command Comman Name Name Value Pair Description dLevel1 Level 2 dLevel3 Value Pairi 2 omconfig system or assetinfo info service renewed true Whether the service servermodul false agreement has been renewed e type lt
125. info action globalrescan Omconfig Set Hot Spare Protection Policy Table 118 Omconfig Set Hot Spare Protection Policy Description Syntax Example for Example Sets the hot spare protection policy for dedicated or global hot spares For more information see the Dell OpenManage Server Administrator Storage Management User s Guide at dell com support manuals omconfig storage globalinfo action setprotectionpolicies type dhs raid lt r1 r5 r6 r10 r50 r60 all hscount lt 1 16 gt warnlevel 0 3 includeghsinvdstate lt yes no Where hscount is the number of hot spares assigned to the virtual disk and warnlevel is the severity level you want to assign to the generated alert if this policy is violated Use hscount 0 warnlevel 0 to reset the dedicated hot spare protection policy for the RAID level Global hot spare protection policy omconfig storage globalinfo action setprotectionpolicies type dhs hscount 1 warnlevel 1 includeghsinvdstate yes Omconfig Connector Commands The following table displays the omconfig command syntax required to execute connector tasks Table 119 omconfig Connector Commands Required Command Levels 1 2 3 omconfig storage connector Optional name value pairs action rescan controller id connector id Omconfig Rescan Connector Description 186 Rescans a controller connector This command rescans all connectors on the controller and is therefore similar to performin
126. ing table displays the valid parameters for the command Table 51 Valid Parameters Of omconfig system assetinfo info acquisition or omconfig servermodule assetinfo info acquisition Command Command Command Name Value Name Value Pair 2 Description Level 1 Level 2 Level 3 Pair 1 omconfig system or assetinfo info acquisiti costcenter lt text gt The name or servermodule on code for the business entity 117 Command Command Command Name Value Name Value Pair 2 Level 1 Level 2 Level 3 Pair 1 expensed yes no installdate mmadyy gt ponum lt n gt purchasecost lt n gt purchasedate lt mmd dyy gt signauth lt text gt waybill lt n gt Example Command For Adding Acquisition Information Description that acquired the system Whether the system is charged to a specific purpose or department such as research and development or sales Date the system was put to service Number of the document that authorized payment for the system Price the owner paid for the system Date the owner purchased the system Name of the person who approved the purchase or the service call on the system Receipt from the carrier for the goods received To provide a value for an acquisition parameter type a command of the form omconfig system assetinfo info acquisition lt name value pair 2 or omconfig servermodule assetinfo info acquisition lt name value pair 2 For example type o
127. ip Values The omconfig system assetinfo or omconfig servermodule assetinfo command helps you to edit a comprehensive set of parameters that make up the total cost of ownership of the system This section explains the parameters that are reported and configured under the omconfig system assetinfo or omconfig servermodule assetinfo command Using the omconfig system assetinfo or omconfig servermodule assetinfo command you can set governing values for configurable objects Examples of assetinfo configuration capabilities include setting values for system owner purchase price details of any lease that is in effect depreciation methods and rates and location of the system warranty and extended warranty duration outsourcing details and service level agreement Es NOTE Power Users and Administrators can add and edit asset information The following table lists the systems on which omconfig commands are applicable Table 50 System Availability for the omconfig Command Command Level 1 Command Level 2 Applicable to omconfig servermodule Blade systems mainsystem Blade systems system Rack and Tower systems chassis Rack and Tower systems Adding Acquisition Information Acquisition refers to the facts about a business entity s purchase or lease of a system Use the omconfig system assetinfo info acquisition or omconfig servermodule assetinfo info acquisition command to add detailed information about the purchase or lease of a system The follow
128. is a standard way to identify the type of device that is sending the interrupt request Connector Type of plug or cable and plug that connects two devices together in this case the type of Type connector that attaches an external device to a system There are many connector types each designed to connect a different device type to a system Examples include DB 9 Male AT Access Bus PS 2 and so on Maximum Port speed Port speed refers to the data transmission rate of an input output channel Speed measured in numbers of bits per second Serial ports usually have a maximum speed of 115 Kbps and USB version 1 x ports have a maximum speed of 12 Kbps Omreport Chassis Processors Or Omreport Mainsystem Processors Use the omreport chassis processors or omreport mainsystem processors command to view properties of the system s processors 36 Server Administrator displays values for the following fields Index Status Connector Name Processor Brand Processor Version Current Speed State and Core Count The following table provides the description of the fields Table 8 Fields and Description Field Description Index Processor number Status Current status of the processor Connector Name or number of the device that occupies the processor slot in the system Name Processor Brand Type of processor made by a manufacturer such as Intel Itanium Intel Pentium III Intel Xeon or AMD Opteron Processor Model and stepping number of t
129. is identification LED This command also allows you to clear the LED of the system hard drive The following table displays the valid parameters for the command Table 26 Valid Parameters Of Omconfig Chassis Leds Or Omconfig Mainsystem Leds name value pair 1 name value pair 2 Description index lt n gt NA Number of the chassis where the LED resides defaults to chassis 0 main system chassis led fault severity warning critical Select to flash the LED either when a warning event occurs or when a critical event occurs led hdfault action clear Sets the number of faults for the hard drive back to zero 0 led identify flash off on time out lt n gt Sets the chassis identification LED to off or on Set the time out value for the LED to flash to a number of seconds Omconfig Chassis Memorymode Or Omconfig Mainsystem Memorymode Use the omconfig chassis memorymode or omconfig mainsystem memorymode command to specify the redundancy mode to use for the system memory in case of memory errors Redundant memory enables a system to switch to other available memory modules if unacceptable errors are detected in the modules that the system is currently using The omconfig chassis memorymode or omconfig mainsystem memorymode command allows you to disable redundancy when you disable redundancy you instruct the system not to switch to other available memory modules when the memory module the system is using begins to encounter errors To enable r
130. istrator performs when a removable flash media fails 105 Event Name Description event storagesyswarn Sets actions when a storage system detects a warning value event storagesysfail Sets actions when a storage system detects a failure value event storagectrlwarn Sets actions when a storage controller detects a warning value event storagectrlfail Sets actions when a storage controller detects a failure value event pdiskwarn Sets actions when a physical disk detects a warning value event pdiskfail Sets actions when a physical disk detects a failure value event vdiskwarn Sets actions when a virtual disk detects a warning value event vdiskfail Sets actions when a virtual disk detects a failure value event enclosurewarn Sets actions when an enclosure detects a warning value event enclosurefail Sets actions when an enclosure detects a failure value event storagectrlbatteryw Sets actions when a storage controller battery detects a warning value arn E NOTE This event is not available on blade systems event storagectrlbatteryf Sets actions when a storage controller battery detects a failure value ail K NOTE This event is not available on blade systems Example Set Alert Action Commands The following are examples of valid example commands For each successful command issued the following message is displayed Alert action s configured successfully Example Current Probe Actions To disable system console alert if a current
131. itystr text Sets the text string that acts as a password and is used to authenticate SNMP messages sent between the BMC and the destination management station Omconfig System Platformevents Or Omconfig Servermodule Platformevents Use the omconfig system platformevents or omconfig servermodule platformevents command to configure shutdown action if any taken for a specific platform event You can also enable or disable platform event filter alert generation CAUTION If you set a platform event shutdown action to anything other than none or power reduction the system is forcefully shutdown when the specified event occurs This shutdown is initiated by firmware and is carried out without first shutting down the operating system or any of the applications running on your system The following table displays the valid parameters for the command NOTE Alert settings are mutually exclusive and you can set one at a time only The action settings are also mutually exclusive and you can set one at a time only However alert and action settings are not mutually exclusive of each other Table 42 Parameters For Alert Action Command Action Description action disable Disables the SNMP alert action enable Enables the SNMP alert action none Takes no action when the system is hung or has crashed action powercycle Turns off the electrical power to the system pauses turns the power on and reboots the system action poweroff Turns off the el
132. k 0 3 omconfig storage pdisk action rebuild controller 1 pdisk 0 2 3 Omconfig Cancel Rebuild Physical Disk Description Syntax Example to Example for SCSI SATA and ATA controllers Example for SAS controllers Cancels a rebuild that is in progress If you cancel a rebuild the virtual disk remains in a degraded state For more information about Cancel Rebuild Physical Disk see the Dell OpenManage Online Help omconfig storage pdisk action cancelrebuild controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Cancel the rebuild of physical disk 5 on connector O of controller 1 On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action cancelrebuild controller 1 pdisk 0 3 omconfig storage pdisk action cancelrebuild controller 1 pdisk 0 2 3 149 Omconfig Cancel Replace Member Description Syntax Example to Example Omconfig Clear Physical Disk Description Syntax Example to Example for SAS controllers Omconfig Cancel Clear Physical Disk Description Syntax 150 Cancels a replace member operation omconfig storage pdisk action cancelreplacemember controller id
133. l 2 command level 3 name value pair 1 name value pair 2 where command levels 1 2 and 3 are represented by omconfig system assetinfo name value pair 1 is represented by info depreciation and name value pair 2 is represented by method straightline To set the depreciation method to straight line type omconfig system assetinfo info depreciation method straightline 17 The CLI responds with the following message Asset information set successfully When you type omconfig system assetinfo the help that displays provides information about assigning values for the name and option fields Partial results for the request omconfig system assetinfo are as follows assetinfo Set asset information For one info value specify one or more optional parameter s The following table displays the optional parameters for info acquisition Table 2 Optional Parameters Info Value Optional parameters Info acquisition purchasecost lt num gt waybill lt num gt installdate lt mmddyy gt purchasedate mmadyy ponum lt num gt signauth lt text gt expensed yes no costcenter text info depreciation method lt text gt duration num percent lt percent gt unit lt months years unknown gt 18 5 omreport Viewing System Status Using The Instrumentation Service The omreport command allows you to see detailed information about the system components You can also retrieve summaries for many system comp
134. le specifies the physical disk Es NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Disable write cache on physical disk 5 on connector 0 of controller 1 On a SAS controller the physical disk resides in enclosure 2 151 Example for SAS controllers Omconfig Export Reliability Log Description Syntax Example to Example for SAS controllers Omconfig Convert RAID To Non RAID Description Syntax Example to Example for SAS controllers 152 omconfig storage pdisk action disabledevicewritecach controller 1 pdisk 0 2 3 Exports log on a physical disk or the PCle SSD controller omconfig storage pdisk action exportreliabilitylog controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk Es NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Export log on physical disk 5 on connector 0 of controller 1 On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action exportreliabilitylog controller 1 pdisk 0 2 3 Converts RAID to non RAID on a physical disk omconfig storage
135. le specifies the physical disk K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Assign physical disk 5 on connector 0 of controller 1 as a global hot spare On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action assignglobalhotspare controller 1 pdisk 0 3 assign yes omconfig storage pdisk action assignglobalhotspare controller 1 pdisk 0 2 3 assign yes Rebuilds a failed physical disk Rebuilding a disk may take several hours If you need to cancel the rebuild use the Cancel Rebuild task For more Syntax Example to Example for SCSI SATA and ATA controllers Example for SAS controllers information about Rebuild Physical Disk see the Dell OpenManage Online Help omconfig storage pdisk action rebuild controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Rebuild physical disk 5 on connector 0 of controller 1 On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action rebuild controller 1 pdis
136. les the intrusion check during system boot enabled Enables the internal USB port e disabled Disables the internal USB port on Enables the mouse e off Disables the mouse e enabled Enables the first NIC during system boot e enabledwithpxe Enables the first NIC during system boot with PXE on if the system has PXE 71 name value pair 1 attribute attribute nic2 attribute nic3 72 name value pair 2 setting setting enabled enabledwithpxe disabled enabledonly enablednonepxe enabledwithiscsi setting enabled enabledwithpxe disabled enabledonly enablednonepxe enabledwithiscsi Description disabled Disables the first NIC during system boot enabledonly Enables the first NIC during system boot with PXE off if the system has PXE enablednonepxe Enables the first NIC during system boot with PXE off if the system has PXE enabledwithiscsi Enables the first NIC during system boot with iSCSI on if the system has iSCSI enabled Enables the second NIC during system boot enabledwithpxe Enables the second NIC during system boot with PXE on if the system has PXE disabled Disables the second NIC during system boot enabledonly Enables the second NIC during system boot with PXE off if the system has PXE enablednonepxe Enables the second NIC during system boot with PXE off if the system has PXE enabledwithiscsi Enables the second NI
137. ller id vdisk id action assigndedicatedhotspare controller id vdisk id pdisk lt PDISKID gt assign lt yes no gt action deletevdisk controller id vdisk id force yes action format controller id vdisk id action reconfigure controller id vdisk id raid lt c rO r1 ric r5 r10 gt pdisk lt PDISKID gt size lt size gt vdcapacityexpansion yes sizeinpercent 1 to 100 gt action securevd controller id vdisk id action clearvdbadblocks controller id vdisk id ction changepolicy controller id vdisk id readpolicy lt ra nra ara rc nrc writepolicy lt wb wt wc nwc fwb cachepolicy lt d c diskcachepolicy enabled disabled gt action replacememberdisk controller id vdisk id source lt PDISKID gt destination lt PDISKID gt action rename controller id vdisk id action enablefluidcache controller id vdisk id devicename lt string gt cachepolicy lt wb wt gt action disablefluidcache controller id vdisk id devicename lt string gt action reactivate controller id vdisk id devicename lt string gt Omconfig Check Consistency Description Syntax Example to Example 154 Initiates a check consistency on a virtual disk The check consistency task verifies the virtual disk s redundant data omconfig storage vdisk action checkconsistency controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command K NOTE To obtain these va
138. llow you to set warning threshold values to default values To set both the upper and lower fan warning threshold values to the recommended default value type omconfig chassis fans index 0 warnthresh default or omconfig mainsystem fans index 0 warnthresh default You cannot default one value and set another In other words if you default the minimum warning threshold value you are also selecting the default value for the maximum warning threshold value Specifying A Value For Minimum And Maximum Warning Thresholds If you prefer to specify values for the fan probe warning thresholds you must specify the number of the probe you are configuring and the minimum and or maximum warning threshold values In the following example the probe that is being configured is probe O The first command sets only the minimum threshold the second sets the minimum and maximum thresholds omconfig chassis fans index 0 minwarnthresh 4580 or omconfig mainsystem fans index 0 minwarnthresh 4580 omconfig chassis fans index 0 minwarnthresh 4580 maxwarnthresh 9160 83 or omconfig mainsystem fans index 0 minwarnthresh 4580 maxwarnthresh 9160 When you issue the command and the system sets the values you specify the following message is displayed Fan probe warning threshold s set successfully NOTE You cannot set the minimum and maximum warning thresholds for the fan probe on PowerEdge 9G system Omconfig Chassis Frontpanel Or Omconfig Mains
139. losure and its enclosure lt ENCLOSUREID gt where id components 155 Required Command Optional name value pairs Use Levels 1 2 3 is the controller number and lt ENCLOSUREID gt is the enclosure ID Example for SCSI controllers controller 0 enclosure 2 Example for SAS controllers controller 0 enclosure 1 2 Omreport Temperature Probe Status The following table describes the syntax for the omreport Probe commands Table 69 Omreport Temperature Probe Commands Required Command Levels 1 2 Optional name value pairs 3 and name value pair omreport storage enclosure controller id enclosure lt ENCLOSUREID gt info temps where id is the controller number and lt ENCLOSUREID gt is the enclosure ID Example for SCSI controllers controller 0 enclosure 2 info temps Example for SAS controllers controller 0 enclosure 1 2 info temps controller id enclosure lt ENCLOSUREID gt info temps index n where id is the controller number and lt ENCLOSUREID gt is the enclosure number and n is the number of a temperature probe For example controller 0 enclosure 2 info temps index 1 Omreport Fan Status Use Displays property information for all enclosures attached to the system Displays the temperature probes for the specified enclosure Displays the temperature probes for the specified enclosure The following table describes the syntax for the omreport Fan commands 136 Table 70 Omreport Fan Status
140. lowing table displays how to specify the raid n parameter for each RAID level and concatenation Table 92 Raid Level And Concatenation RAID Level or Concatenation raid n Parameter Specification RAID O raid r0 RAID 1 raid r1 RAID 5 raid r5 RAID 6 raid r6 RAID 10 raid r10 RAID 50 raid r50 RAID 60 raid r60 RAID 1 concatenated raid ric Concatenation raid c size lt number max min gt The following table displays how to specify the size lt number max min gt 168 Table 93 Size Parameter sizez number max min Parameter Description Specification size lt n gt Use this specification to indicate a specific size for the virtual disk The virtual disk size is specified in b bytes m megabytes or g gigabytes For example size 500m indicates that the virtual disk is 500 MB size max To create a virtual disk that is the maximum size possible specify size max When creating a RAID 50 virtual disk this parameter is specified as size max size min To create a virtual disk that is the minimum size possible specify size min PDISKID lt connector enclosurelD targetID connector targetlD gt Use this parameter to specify the physical disks to be included in the virtual disk When reconfiguring a virtual disk you must specify all physical disks to include in the reconfigured virtual disk The physical disk specification applies to physical disks in the original virtual disk and continues in the
141. lues type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Run a check consistency on virtual disk 4 on controller 1 omconfig storage vdisk action checkconsistency controller 1 vdisk 4 Omconfig Cancel Check Consistency Description Syntax Example to Example Cancels a check consistency while in progress omconfig storage vdisk action cancelcheckconsistency controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command Es NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Cancel a check consistency on virtual disk 4 on controller 1 omconfig storage vdisk action cancelcheckconsistency controller 1 vdisk 4 Omconfig Pause Check Consistency Description Syntax Example to Example Pauses a check consistency while in progress For more information see the Dell OpenManage Online Help omconfig storage vdisk action pausecheckconsistency controller id vdisk id where idis the controller ID and virtual disk ID as reported by the omreport command A NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk cont
142. m controller id where id is the controller ID as reported by the omreport storage controller command Test the alarm on controller 1 omconfig storage controller action testalarm controller 1 Omconfig Reset Controller Configuration Description Syntax Example to Example Resets the controller configuration A CAUTION Resetting a configuration permanently destroys all data on all virtual disks attached to the controller System or boot partition residing on these virtual disks is destroyed You may receive a warning message if this command results in deleting the system or boot partition However this warning message is not generated always Ensure that you do not delete the system or boot partition or other vital data when using this command omconfig storage controller action resetconfig controller id where id is the controller ID as reported by the omreport storage controller command In some circumstances you may receive a warning message if this command deletes the system or boot partition You can override this warning by using the force yes parameter In this case the syntax is as follows omconfig storage controller action resetconfig controller id force yes Reset the configuration on controller 1 omconfig storage controller action resetconfig controller 1 omconfig Create Virtual Disk The Dell OpenManage Online Help provides additional information about creating virtual disks The omconfig syntax f
143. mart Thermal Shutdown By default the operating system and server shut down when the PV220S and PV221S enclosures reach a critical temperature of O or 50 degree Celsius However if you have implemented connector redundancy on the PV220S and PV221S enclosures you can specify that only the enclosure and not the operating system and server are shut down when the enclosure reaches a critical temperature of 0 or 50 degree Celsius Specifying that only the enclosure is shut down during excessive temperatures is Known as Smart Thermal Shutdown For more information about Smart Thermal Shutdown see the Dell OpenManage Online Help Description Enables smart thermal shutdown Syntax omconfig storage globalinfo action enablests Example to Enable thermal shutdown The omconfig command syntax for enabling thermal shutdown does not require a controller or enclosure ID K NOTE You can use the omreport storage globalinfo command to determine whether smart thermal shutdown is currently enabled or disabled The status of smart thermal shutdown is also displayed by the Server Administrator graphical user interface GUI To locate this status select the Storage object and the Information Configuration tab Example omconfig storage globalinfo action enablests Omconfig Global Disable Smart Thermal Shutdown If you have previously enabled smart thermal shutdown using the omconfig command you can disable smart thermal shutdown and return the system to its d
144. mconfig system assetinfo info acquisition purchasedate 122101 or omconfig servermodule assetinfo info acquisition purchasedate 122101 118 The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all of the parameters for name value pair 2 belong to the same name value pair 1 For example to type more than one parameter value for info acquisition use the following example as a syntax guide omconfig system assetinfo info acquisition purchasecost 5000 waybill 123456 installdate 120501 purchasedate 050601 ponum 9999 signauth John Smith expensed yes costcenter finance or omconfig servermodule assetinfo info acquisition purchasecost 5000 waybill 123456 installdate 120501 purchasedate 050601 ponum 9999 signauth John Smith expensed yes costcenter finance The following message is displayed Asset information set successfully Adding Depreciation Information Depreciation is a set of methods for computing the devaluation of the asset over time For example the depreciation of a system that is expected to have a useful life of 5 years is 20 percent Use the omconfig system assetinfo info depreciation or omconfig servermodule assetinfo info depreciation command to add details about how the system s depreciation is computed The following table shows the valid parameters for the command
145. memory module resides the default is chassis 0 the main system chassis redundancy spare mirror disabled raid5 dddc spare Disables the memory module that has a correctable memory event and copies the failing module s data to a spare bank mirror Switches the systems to a mirrored copy of the memory if the failing module has an uncorrectable memory event In the mirror mode the operating system does not switch back to the original module until the system reboot disabled Indicates that the system is not to use other available memory modules if uncorrectable memory events are detected raid5 Method of system memory configuration This is logically similar to the RAID 5 mode used in hard drive storage systems This memory mode provides an extra level of memory checking and error recovery at the expense of some memory capacity The RAID mode supported is RAID level 5 striping with rotational parity dddc The dddc mode enables double device data correction This ensures data availability after hard failure of x4 DRAM opmode mirror optimizer advecc mirror Switches the systems to a mirrored copy of the memory if the failing module has an uncorrectable memory event In the mirror mode the operating system does not switch back to the original module until the system reboots optimizer Enables the DRAM controllers to operate independently in 64 bit mode and provide optimized memory performance 87 name value pai
146. ment about the actions performed using omreport The following table lists the omreport commands available for about system and main system chassis Table 4 Command Level 1 Level 2 And Level 3 For omreport Command Command Level Command User Use Level 1 2 Level 3 Privilege Required omreport modularenclosu U P A Displays the information for all the re modular chassis about U P A Displays the version number and properties for Server Administrator details true U P A Displays the information for all the Server Administrator programs installed chassis or U P A Displays the general status of all the main mainsystem components acswitch U P A Displays the failover settings where redundant AC power lines are supported in a system batteries U P A Displays the properties set for batteries bios U P A Displays the BIOS information such as manufacturer version and release date biossetup A Displays the BIOS setup properties configured during system boot fans U P A Displays the status and thresholds for system fans firmware U P A Displays the name and version of the firmware frontpanel U P A Displays whether the front panel button settings such as the Power button and or 20 Command Level 1 Command Level Command 2 Level 3 fru hwperforman ce info intrusion leds memory nics ports processors pwrmanagem ent pwrmonitorin 9 pwrsupplies remoteaccess slots temps Us
147. mework x x x Server Administrator Core files x x x Server Administrator Instrumentation files x x x Server Administrator Core files x x x Server Instrumentation SNMP Module x x x Server Instrumentation WMI Module x x x Storage Management x x x Microsoft Windows Server 2008 R2 Edition Version 6 1 Build 7601 Service Server Full Installation Fri May 20 18 02 52 2XXX Wed May 18 18 37 58 2XXX WIN GSFCCED6N2D Please set the valu PowerEdge FM120 SST 3 4 S CB2DX1S Enterprise x64 Pack 1 x64 55 Express Service Cod Slot Number Slot Name Form Factor Node Id Remote Access Information Remote Access Devic vFlash Media Processor 1 Processor Brand Processor Version Voltage emory m otal Installed Capacity emory Available to the OS m otal Maximum Capacity emory Array Count emory Array 1 Location Use Installed Capacity aximum Capacity Slots Available Slots Used ECC Type BIOS Information Manufacturer Version Release Date Firmware Information Name 54 26790524560 Slot 8 SLOT 02 1U Half Width CB2DX1Sc iDRAC7 Express Absent Genuine Intel R CPU 4000 2 41GHz Model 77 1000 mV 4096 MB 4096 MB 32768 MB 1 System Board or Motherboard System Memory 4096 MB 32768 MB 24 1 Multibit ECC Dell Inc 0 1 10 07 31 2013 iDRAC7 Version 1 50 50 Build 3 Firmware I
148. minimum warning threshold by 200 RPM and has decreased the maximum warning threshold by 2000 RPM Selecting A Format For The CLI Command Output You can specify a format for the CLI command results The format determines how the command output is displayed If the command results are directed to a file the format is captured by the file to which you write the command results The available formats include List Ist e Semicolon separated values ssv Table tbl e Custom delimited format cdv The syntax for the formatting option is command fmt format option For example type omreport system summary fmt tbl or omreport servermodule summary fmt tbl where fmt tbl specifies table format You can combine the formatting option with the option to direct output to a file For example type omreport system summary fmt tbl outa summary txt or omreport servermodule summary fmt tbl outa summary txt where fmt tbl specifies table format and outa specifies that you append the command results to a file named summary txt List Ist The default format is lst or list format Use this format when you want to optimize output for simple readability You need to specify a format for the command output only if you want a format other than the lst format To see the following example command output in lst format type omreport system summary or omreport servermodule summary 196 No special
149. ministrator programs that are installed preferences cdvformat A Specifies the delimiter for separating data fields reported in custom delimited format cdv dirservice A Configures the Microsoft Active Directory service messages A Displays the configured alert message format useraccess A Determines whether users below the administrator level are allowed to use Server Administrator or not webserver A Allows the administrator to set the encryption levels of the Web server and configure the URL launch point in the Server Administrator Web server environment system or servermodule alertaction P A Determines in advance the actions taken for warning or failure events on intrusion fans temperatures voltages power supplies memory and redundancy 62 Comman d Level 1 Command Level 2 chassis or mainsystem Command Level 3 alertlog assetinfo cmdlog esmlog events pedestinations platformevent S recovery shutdown thrmshutdow n webserver biossetup fans frontpanel info leds memorymode User Privilege Required DA P A Y gt Use Allows the administrator to clear the alert log Enters and edits cost of ownership information for the system including values for depreciation lease maintenance service and support Allows the administrator to clear the command log Allows the administrator to clear the ESM log Enables or disables SNMP traps Sets IP ad
150. mmand Output DISplay 3 4 p o Bobi Re re neta wee A bd Pre Meare ae 193 Writing Command Output To A File i deser rte RR nde kite pnta ra aere dap ua aa n idea 194 Saving Command Results To A File That Is Ovenwritten 194 Append Command Results To An Existing File 195 Selecting A Format For The CLI Command Output ssssssssseseeeeeeeeeeeenenennennes 196 AUi P 196 Table MPi ere ERR ee e e Re RR OR TERN 197 Semicolon Separated Values Lee 197 Custom Delimited Format cd 198 10 Introduction Dell OpenManage Server Administrator OMSA provides a comprehensive one to one systems management solution through either an integrated Web browser based graphical user interface GUI or a command line interface CLI Server Administrator is designed for system administrators to manage systems locally and remotely on a network It allows system administrators to manage their entire network by providing a comprehensive one to one systems management In the context of Server Administrator a system refers to a stand alone system a system with attached network storage units in a separate chassis or a Blade system consisting of one or more server modules in a modular enclosure Server Administrator provides easy to use management and administration of local and remote systems through a comprehensive set of integrated management services Server Administrator is the sole installation on the sy
151. motherboard next to the slot Alphanumeric text uniquely identifies each slot in the system Adapter Name and or type of the card that fits into the slot for example a storage array controller SCSI adapter iDRAC Enterprise or HBA Data Bus Width in bits of the information pathway between the components of a system The range Width of the data bus width is from 16 to 64 bits Omreport Chassis Temps Or Omreport Mainsystem Temps Use the omreport chassis temps or omreport mainsystem temps command to view properties of the system s temperature probes Type omreport chassis temps index n or omreport mainsystem temps index n The index parameter is optional If you do not specify the index Server Administrator displays a summary of status readings and thresholds set for any temperature probes that are present on the system If you specify the index Server Administrator displays the summary for a specific temperature probe Omreport Chassis Volts Or Omreport Mainsystem Volts Use the omreport chassis volts or omreport mainsystem volts command to view properties of the system s voltage probes Type omreport chassis volts index n 44 or omreport mainsystem volts index n The index parameter is optional If you do not specify the index Server Administrator displays a summary of status readings and thresholds set for any voltage probes that are present on the system If you specify the index Server Administrator display
152. mple Re keys the encryption key in LKM mode for the controller omconfig storage controller action rekeylkm controller id keyid lt keyid gt passphrase lt passphrase string gt escrow yes filepath Absolute path to the escrow file where idis the controller ID as reported by the omreport storage controller command Re key the encryption key for the controller omconfig storage controller action rekeylkm controller 1 Omconfig Convert Multiple RAID To Non RAID Description Syntax Converts multiple RAID to non RAID on the given controller omconfig storage controller action convertraidtononraid controller id pdisk lt PDISKID gt where id is the controller ID as reported by the omreport storage controller command and PDISKID is specified as pdisk connector enclosureID targetID connector targetID 179 Example to Example Convert multiple non RAID to RAID on controller O omconfig storage controller action convertnonraidtoraid controller 0 pdisk 0 2 3 Omconfig Convert Multiple Non RAID To RAID Description Syntax Example to Example Converts multiple non RAID to RAID on the given controller omconfig storage controller action convertnonraidtoraid controller id pdisk lt PDISKID gt where id is the controller ID as reported by the omreport storage controller command and PDISKID is specified as pdisk connector enclosureID targetID connector targetID Convert multiple non RAID to RAID on controller O
153. mptraps or omconfig servermodul vents source snmptraps Type Type refers to the name of the component s involved in the event The following table displays the valid parameters for system event types Table 44 System Event Type Parameters name value pair Description type accords Configures events for AC power cords type battery Configures events for battery type all Configures events for all device types type fanenclosures Configures events for fan enclosures type fans Configures events for fans type intrusion Configures events for chassis intrusion type log Configures events for logs type memory Configures events for memory type powersupplies Configures events for power supplies type redundancy Configures events for redundancy type systempower Configures events for system power type temps Configures events for temperatures type volts Configures events for voltages type systempeakpower Configures events for system peak power type removableflashme Configures events for removable flash media dia Severity In the context of configuring events severity determines how severe an event is before Server Administrator notifies you of the event for a component type When there are multiple components of the same type in the same system chassis you can specify whether you want notification for event severity according to the number of the component by using the index lt n gt parameter The following table displays
154. n Chassis Information Attribute Model Value Modular Server Enclosure Attribute Lock Value true Attribute Service Tag Value 8RLNB1S 235 Attribute Express Service Cod Value 18955029124 CMC Information Attribute Product Value Chassis Management Controller CMC Attribute Description Value The system component provides a complete set of remote managementfunctions for Dell systems Attribute Version Value 9320 Attribute IP Address Value 101 102 103 104 Attribute IP Address Source Value Dynamic Source Attribute IP Address Type Value IPv4 Attribute Remote Connect Interfac Value Launch CMC Web Interface omreport about Use the omreport about command to learn the product name and version number of the systems management application installed on the system The following is an example output from the omreport about command Product name Dell OpenManage Server Administrator Version ARA Copyright Copyright C Dell Inc xxxx xxxx All rights reserved Company Dell Inc For details about the environment for Server Administrator type omreport about details true Server Administrator includes a number of services each of which has a version number of its own The Contains field reports version numbers for the services as well as other useful details The following output is an example and can change depending on the system s co
155. n numbers of the BIOS firmware systems management software and operating system installed on the system Type omreport system version or omreport servermodule version NOTE If iDRAC is installed Server Administrator displays the Lifecycle Controller version If BMC is installed Server Administrator displays the USC version 57 The output that is displayed in the CLI window depends on the version of the BIOS RAID controllers and firmware installed on the system The following partial command results are unique and may not resemble the results for the configuration of the system Version Report Name BIOS Version 2035 Name iDRAC7 Version 2 1200 Software Name Microsoft Windows Server 2008 R2 Enterprise x64 edition Version Version 6 1 Build 7600 x64 Server Full Installation Name Dell Server Administrator Version iux Name PERC H310 Mini Version 20 10 1 0025 Omreport Preferences Commands Use the omreport preferences command to view the URL details of the Server Administrator Web server key sign algorithm JRE and message format Omreport Preferences Messages Use the omreport preferences messages to view the configured alert message format The following table lists the available attributes of omreport preferences messages Table 16 Valid Parameters Of Omreport Preferences Messages name value pair Description attribute format Reports the currently configured alert message form
156. n Or Omreport Servermodule Shutdown sss 52 Omreport System Summary Or Omreport Servermodule Summary 52 Omreport System Thrmshutdown Or Omreport Servermodule Thrmshutdown 57 Omreport System Version Or Omreport Servermodule Version 57 Omreport Preferences Commands arrei Se e A Er A 58 Omreport Preferences Messages ose d esie ds re Ll e Ere i Le Ld ne in 58 Omreport Preferences Webserver 5 testet ed id e n ne tr n eret v Y PL 58 4 Omconfig Managing Components Using The Instrumentation o c A laura ge 61 Conventions For Parameter Tables invocan e o et ee e e Re ER dE ince 61 omconfig Command Summa 5 4 ls a ERR d ee t TRIP ee ces 62 Help With The Omconfig Commande 64 Ormmconfig ABOUT ettet Dec eto td eir eb e edebat eot e nete nce 65 Omconfig Chassis Or Omconfig Malnsvstem nene 66 Omconfig Chassis Biossetup Or Omconfig Mainsystem Blossetup 66 Omconfig Chassis Currents Or Omconfig Mainsystem Currents Omconfig Chassis Fans Or Omconfig Mainsystem Fans Omconfig Chassis Frontpanel Or Omconfig Mainsystem Frontpanel 84 Omconfig Chassis Info Or Omconfig Mainsystem Info 85 Omconfig Chassis Leds Or Omconfig Mainsystem Leds ee 86 Omconfig Chassis Memorymode Or Omconfig Mainsystem Memorvmocde 86 Omconfig Chassis Pwrmanagement Or Omconfig Mainsystem Pwrmanagement 88 Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoring Omconfig Chassis Remoteaccess Or Omconfig Mainsyst
157. n convertnonraidtoraid command For more information see omconfig Convert Multiple Non RAID To RAID Es Convert non RAID to RAID on physical disk 3 on connector O of controller 1 On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action nonraidtoraid controller 1 pdisk 0 2 3 Omconfig Virtual Disk Commands The following table provides the omconfig command syntax required to execute virtual disk tasks CAUTION The omconfig storage vdisk action deletevdisk controller id vdisk id command deletes a virtual disk Deleting a virtual disk destroys all information including file systems and volumes residing on the virtual disk Table 87 Omconfig Manage Virtual Disk Commands Required Command Levels 1 2 3 omconfig storage vdisk Optional name value pairs action checkconsistency controller id vdisk id action cancelcheckconsistency controller id vdisk id action pausecheckconsistency controller id vdisk id action resumecheckconsistency controller id vdisk id action checkconsistency controller id vdisk id action blink controller id vdisk id action unblink controller id vdisk id action initialize controller id vdisk id 153 Required Command Levels 1 2 3 Optional name value pairs action fastinit controller id vdisk id forcez yes action slowinit controller id vdisk id force yes action cancelinitialize controller id vdisk id action cancelbginitialize contro
158. n in the range of 0 to 7 administrator Sets the maximum privilege level that is accepted on a LAN channel to Administrator operator Sets the maximum privilege level that is accepted on a LAN channel to Operator user Sets the maximum privilege level that is accepted on a LAN channel to User text Text used for encryption and confirmation of encryption K NOTE The text option is supported only on PowerEdge 9G systems Validates the preferred DNS server for configuration 9600 Sets the connection speed to 9600 bits per second 19200 Sets the connection speed to 19200 bits per second NOTE Baud rates of 9600 and 19200 are supported on PowerEdge 1800 1850 2800 and 2850 systems 38400 Sets the volatile and non volatile connection speed to 38400 bits per second 57600 Sets the volatile and non volatile connection speed to 57600 bits per second NOTE Baud rates of 19200 38400 and 57600 are supported on PowerEdge 9G systems 115200 Sets the volatile and non volatile connection speed to 115200 bits per second K NOTE Baud rate of 115200 is supported on certain systems that have a DRAC 5 installed K NOTE Baud rate of 19200 57600 and 115200 are supported on 10G systems that have iDRAC installed none No control over the flow of communication through the serial port rtscts RTS is ready to send and CTS is clear to send directbasic Type of messaging used for IPMI messaging over a
159. nManage Server Administrator The following table displays the fields that are displayed for each cache on a particular processor Table 10 Fields And Description Field Description Status Reports whether a specific cache on the processor is enabled or disabled Level Refers to a primary or secondary cache Primary level cache is a memory bank built into the processor Secondary level cache is a staging area that feeds the primary cache A secondary level cache is built into the processor or resides in a memory chipset outside the processor The internal processor cache is referred to as a Level 1 or L1 L2 cache is the external cache in a system with an Intel Pentium processor and it is the second level of cache that is accessed The names L1 and L2 are not indicative of where the cache is physically located internal or external but describe which cache is accessed first L1 therefore internal Speed Refers to the rate at which the cache can forward data from the main memory to the processor Max Size Maximum amount of memory that the cache can hold in kilobytes Installed Size Actual size of the cache Type Indicates whether the cache is primary or secondary Location Location of the cache on the processor or on a chipset outside the processor Write Policy Describes how the cache deals with a write cycle In a write back policy the cache acts like a buffer When the processor starts a write cycle the cache receives the d
160. nd output for later analysis or comparison Whether you display command results to standard output or have the command results written to a file you can format the results The format you select determines the way the command output is displayed and the way the command output is written to a file Controlling Command Output Display Each operating system provides a means of controlling the way that command results display to standard output The following is a useful command for ensuring that command results do not scroll by before you can view them The same command syntax works for the Microsoft Windows command prompt the Red Hat Enterprise Linux terminal and the SUSE Linux Enterprise Server terminal To display command output with control over scrolling type the CLI command and append the pipe symbol followed by more For example type omreport system summary more or omreport servermodule summary more The multiscreen system summary displays the first screen When you want to see the next screen of command output press the spacebar 193 Writing Command Output To A File When redirecting command results to a file you can specify a filename and a directory path if necessary to which you want to write the command result When specifying the path to which you want to write the file use the appropriate syntax for the operating system You can save command results in two ways You can overwrite any file that has the same name
161. neous Settings One Time Boot 78 name value pair 1 attribute attribute InternalUsb1 attribute InternalUsb2 attribute loatEngine attribute OsWatchdog Timer attribute SriovGlobalEnable attribute UsbPorts attribute MemOpMode attribute MemOpVoltage attribute MemTest attribute Nodelnterleave attribute SerialDbgOut attribute SysMemSize attribute SysMemSpeed attribute SysMemType attribute SysMemVolt attribute VideoMem attribute AssetTag attribute Characterization attribute ErrPrompt attribute NumLock attribute ReportKbdErr attribute SystemUefiShell attribute OneTimeBootMode attribute OneTimeBootSeqDev attribute OneTimeHddSeqDev attribute OneTimeUefiBootSeq Dev name value pair 2 setting setting On Off setting On Off setting Enabled Disabled setting Enabled Disabled setting Enabled Disabled setting AllOn OnlyBackPortsOn AllOff setting OptimizerMode SpareMode MirrorMode AdvEccMode SpareWithAdvEccMode setting AutoVolt Volt15V setting Enabled Disabled NOTE Volt15V represents 1 5 Volt setting Enabled Disabled setting Enabled Disabled setting string setting string setting string setting string setting string setting string setting Enabled Disabled setting Enabled Disabled setting On Off setting Report NoReport setting Enabled Disabled setting Disabled OneTimeBootSeg OneTimeHddSeq OneTimeUefiBootSe
162. newpw text confirmnewpw text id number serialaccesslevel administrator operator user none id number lanaccesslevel administrator operator user none id user id dracusergroup admin poweruser guest custom none Description enableserialoverlan true Enables serial over LAN enableserialoverlan false Disables serial over LAN K NOTE The enableserialoverlan option is supported only on PowerEdge 9G systems id number ID in numeric format of the user being configured name text Name of the user id number ID in numeric format of the user being configured newpw text New password of the user confirmnewpw text Confirm the new password id number ID in numeric format of the user being configured serialaccesslevel administrator User with an ID has access privileges of an Administrator for the serial port channel serialaccesslevelzoperator User with an ID has access privileges of an Operator for the serial port channel serialaccesslevel user User with an ID has access privileges of a User for the serial port channel serialaccesslevelznone User with an ID does not have access privileges for the serial port channel id number ID number of the user being configured lanaccesslevel administrator User with an ID has access privileges of an Administrator for the LAN channel lanaccesslevel operator User with an ID has access privileges of an Operator for the LAN
163. nfiguration and the version of Server Administrator installed on the system 24 Contains Instrumentation Service 7 x x Storage Management 4 x x Sun Java Runtime Environment 1 x x xx Secure Port Server 7 x x Server Administrator Core Files 7 x x Instrumentation Service Integration Layer 7 x x Server Administrator Common Framework 7 x x Common Storage Module 4 x x Data Engine 7 x x Instrumentation Service 7 x x Omreport Chassis Or Omreport Mainsystem Commands Use the omreport chassis or omreport mainsystem commands to view details for the entire chassis or for a particular component Type omreport chassis or omreport mainsystem Server Administrator displays a general status for the main system chassis or main system components Health Main System Chassis SEVERITY COMPONENT Ok Fans Critical Intrusion Ok Memory Ok Power Supplies Ok Temperatures Ok Voltages Omreport Chassis Acswitch Or Omreport Mainsystem Acswitch Use the omreport chassis acswitch or omreport mainsystem acswitch command if the system has redundant AC power lines that are configured in a failover arrangement Type omreport chassis acswitch or omreport mainsystem acswitch Server Administrator displays the following output AC Failover Switch AC Switch Redundancy 25 Redundancy Status Full Number of devices required 222 for full redundancy Redundancy Mode Redundancy Configuration Input Sour
164. nformation Name Lifecycle Controller 2 Version 930 518 Remote Access Controller Information Product iDRAC7 Express IP Address 10 94 146 217 IP Subnet 255 255 25540 IP Gateway 10 94 146 1 IPv6 Address 1 IPv6 Address 2 IPv6 Gateway Network Interface O0 IP Address 2 XX XX XX XX Subnet Mask T KXXX XX XX Default Gateway 2 XX XX XX XX MAC Address DoD XX XX XX XX XX XX Network Interface 1 IP Address DOMIGVXXSIXX XX Subnet Mask DOXX XX OXX XX Default Gateway DOXX OXX OXX XX MAC Address D 1 XX XX XX XX XX XX Hardware Information Using Omreport System Summary Or Omreport Servermodule Summary The system summary hardware information includes data values for installed components of the following types present in the system 55 System Attributes e Host Name e System Location e Life Cycle Controller Main System Chassis Or Main System Chassis e Chassis Model e Chassis Service Tag Express Service Code e Chassis Lock Chassis Asset Tag Remote Access Information e Remote Access Device e vFlash Media e vFlash Media Size Processor The following are listed for each processor in the system e Processor Brand e Processor Family e Processor Version e Current Speed e Maximum Speed e External Clock Speed e Voltage Memory Total Installed Capacity e Memory Available to the Operating System e Total Maximum Capacity e Memory Array Count Memory Array The following details are listed for each mem
165. ng table displays the usage of dracusergroup custom Table 31 Valid Parameters of omconfig chassis remoteaccess config user id lt user id dracusergroup custom or omconfig mainsystem remoteaccess config user id lt user id dracusergroup custom name valu e pair 1 config user id user id 98 name value pair 2 name value pair 3 Description dracusergroup custo m logindrac true false true or false Enables or disables logging into DRAC configuredrac true false true or false Enables or disables configuration of DRAC configure users true false true or false Enables or disables configuration of users clearlogs true false true or false Enables or disables log clearance executeservercommands tru true or false Enables or disables e false execution of server commands accessconsoleredir true true or false Enables or disables false access to console redirection name valu namecvalue pair 2 name value pair 3 Description e pair 1 accessvirtualmedia true true or false Enables or disables false access to virtual media testalerts true false true or false Enables or disables test alerts Usage of Extipmiusergroup custom The following table displays the usage of extipmiusergroup custom Table 32 Usage Of extipmiusergroup custom name value pair 1 name value pair 2 name value pair 3 Description config user id user id loginidrac true false true or false Enables or extipmiusergroup
166. ngs for the serial port e Advanced settings for a serial over LAN connection e Information on a BMC or RAC user e Information on IPv6 and IPv4 interfaces K NOTE Enter the user ID to configure user information Type omconfig chassis remoteaccess or omconfig mainsystem remoteaccess The output of the omconfig chassis remoteaccess or omconfig mainsystem remoteaccess command lists each of the available configurations The following table displays the valid parameters Table 30 Valid Parameters Of Omconfig Chassis Remoteaccess Or Omconfig Mainsystem Remoteaccess name value pair 1 name value pair 2 Description config config additional ipv4 enable disable enable IPv4 stack to load on iDRAC disable IPv4 stack to flush on iDRAC ipv6 enable disable enable Enables IPv6 stack to load on iDRAC disable Disables IPv6 stack to unload on iDRAC K NOTE This option requires license to enable or disable ipv6 If the appropriate license is not installed or has expired the system displays an error message For more information see Dell License Manager at dell com openmanagemanuals config advsol characcuminterval number number Sets the character accumulate interval in 5 millisecond intervals charsendthreshold number number Sets the number of characters BMC automatically sends a serial over LAN data packet that contains the number of characters as soon as this number of characters or greater has been accepted from
167. ntax has three levels omconfig storage pdisk The following table describes these command levels Table 62 Example Command Levels Command level 1 Command level 2 Command level 3 Use omconfig Specifies the command storage Indicates the Server Administrator service in this case Storage Management that implements the command pdisk Specifies the type of object on which the command operates Following the command levels the omreport and omconfig command syntax may require one or more name value pairs The name value pairs specify exact objects such as a specific physical disk or options such as blink or unblink that the command implements For example the following omconfig command syntax for blinking a physical disk has three levels and three name value pairs omconfig storage pdisk action blink controller id pdisk PDISKID where PDISKID onnector enclosureID targetID connector targetID gt 129 In this example the id in controller idis the controller number such that controller 1 is specified as controller 1 Syntax Of Command Elements The omreport and omconfig commands have multiple name value pairs These name value pairs may include required optional and variable parameters The following table describes the syntax used to indicate these parameters Table 63 Syntax For Name Value Pairs Syntax Description controller id Indicates the controller ID as reported by the omreport storage controller comman
168. nthresh default 99 or omconfig mainsystem temps index 0 warnthresh default You cannot default one value and set another In other words if you set the minimum warning threshold value to the default value you are also selecting the default value for the maximum warning threshold value E NOTE The capabilities for managing sensors vary by systems Specify A Value For Minimum And Maximum Warning Thresholds To specify values for the temperature probe warning thresholds you must specify the number of the probe you are configuring and the minimum and or maximum warning threshold value In the following example the probe that is being configured is probe 4 omconfig chassis temps index 4 minwarnthresh 11 2 maxwarnthresh 58 7 or omconfig mainsystem temps index 4 minwarnthresh 11 2 maxwarnthresh 58 7 When you issue the command and the system sets the values you specify the following message is displayed Temperature probe warning threshold s set successfully NOTE On PowerEdge 9G system you can set the temperature probe warning threshold only for ambient temperature Omconfig Chassis Volts Or Omconfig Mainsystem Volts Use the omconfig chassis volts or omconfig mainsystem volts command to set voltage probe warning thresholds As with other components you can view both warning and failure threshold values but you cannot set failure threshold values The system manufacturer sets the minimum and maximum values for the failur
169. ntroller id action stoppatrolread controller id action createcachecade controller id pdisk lt PDISKID gt name lt string gt action enablelkm controller id keyid lt keyid gt passphrase lt passphrase string lescrow yes filepath lt Absolute path to the escrow file gt K NOTE If you set escrow yes specify the escrow file path action switchtolkm controller id keyid lt keyid gt passphrase lt passphrase string gt escrow yes filepath lt Absolute path to the escrow file gt K NOTE If you set escrow yes specify the escrow file path action rekeylkm controller id action convertraidtononraid controller id pdisk lt PDISKID gt action convertnonraidtoraid controller id pdisk lt PDISKID gt Omconfig Rescan Controller Description Syntax Example to Example Rescans a controller For more information see the Dell OpenManage Online Help omconfig storage controller action rescan controller id where id is the controller ID as reported by the omreport storage controller command Rescan controller 1 omconfig storage controller action rescan controller 1 Es NOTE The rescan controller is not supported on non RAID SCSI and SAS controllers Reboot the system to make the configuration changes visible on non RAID SCSI controllers Omconfig Enable Controller Alarm Description Syntax Example to Example Enables the controller alarm For more information see the Dell OpenManage Online Help
170. of controller 1 On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action offline controller 1 pdisk 0 3 omconfig storage pdisk action offline controller 1 pdisk 0 2 3 147 Omconfig Online Physical Disk Description Syntax Example to Example for SCSI SATA and ATA controllers Example for SAS controllers Omconfig Assign Global Hot Spare Description Syntax Example to Example for SCSI SATA and ATA controllers Example for SAS controllers Omconfig Rebuild Physical Disk Description 148 Brings an offline physical disk back online omconfig storage pdisk action online controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Bring physical disk 5 on connector 0 of controller 1 back online On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action online controller 1 pdisk 0 3 omconfig storage pdisk action online controller 1 pdisk 0 2 30 Assigns a physical disk as a global hot spare omconfig storage pdisk action assignglobalhotspare controller id pdisk lt PDISKID gt assign yes where id is the controller ID The lt PDISKID gt variab
171. olts removableflas hmedia alertaction alertlog assetinfo cmdlog esmlog events operatingsyst em pedestination S platformevent S recovery shutdown summary User Privilege Required U P A U P A U P A Use Displays the status and thresholds for the system voltage sensors Displays the system s virtual flash vFlash and secure digital SD card details Displays the digital licenses of the installed hardware devices of the system See Using The Storage Management Service Displays a high level summary of system components Displays the warning and failure threshold values as well as actions configured when an essential component detects a warning or failure state Allows the administrator to display the alert log Displays the cost of ownership information for the system Allows the administrator to display the command log Allows the administrator to display the hardware log Displays the system s Simple Network Management Protocol SNMP event settings Displays the name and version of the operating system Displays the destinations to send the configured alerts for platform events Displays the system s response for each listed platform event Displays how the system is configured to respond to a hung operating system Displays how to perform the shutdown action Displays the key facts for all system components including main system chassis
172. om profile is selected K NOTE Reboot the system for the power profiles setup options to take effect Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoring Use the omconfig chassis pwrmonitoring or omconfig mainsystem pwrmonitoring command to configure power consumption information The following table displays the valid parameters for the command 89 Table 29 Valid Parameters Of Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoring name value pair 1 name value pair 2 Description index lt n gt NA Number of the probe or probe index must specify config probe warnthresh settodefault Sets the minimum and maximum warning thresholds values to default warnthresh lt n gt Sets a value for the warning threshold unit watt btuphr watt Displays the unit in Watts btuphr Displays the unit in BTU hr config resetreading type energy peakpower energy Resets the system energy reading peakpower Resets the system peak power NOTE This command is applicable only on selected Dell 10G systems that support PMBus E NOTE Power monitoring requires license to configure the power budget information If the appropriate license is not installed or has expired the system displays an error message For more information see Dell License Manager at dell com openmanagemanuals Default Warning Thresholds E NOTE Sensor managing capabilities vary across systems To set both the upper and lowe
173. on Status The following table describes the syntax for the omreport partition commands Table 81 omreport Partition Command Required Command Levels 1 2 Optional name value pairs Use 3 And name value pair Displays the partition details of the specified virtual disk omreport storage partition controller id vdisk id where id is the controller number and the virtual disk number For example controller 0 vdisk 1 Omreport Fluid Cache Disk Status Displays all the partitions in the specified virtual disk on the controller The following table describes the syntax for the omreport fluidcachedisk commands 141 Table 82 omreport Fluid Cache Disk Command Required Command Levels 1 2 3 And Use name value pair omreport storage fluidcachedisk Displays the properties of the fluid cache disks Omreport Storage Tape The following table describes the syntax for the omreport storage tape command Table 83 Omreport Storage Tape Commands Required Command Levels Optional name value pairs Use 1 2 3 omreport storage tape Display tape drive properties controller id where id is the Displays all tape drives controller number For example controller 0 connector id Displays all the tape drives on the specified connector tape lt tape id gt where Displays the specified tape drive tapeid id lt connector targetID gt 142 8 Omconfig Storage Commands omconfig storage Table 84 Omconfig Storage
174. on disablewithdiscard fluidcachedisk lt string gt Omconfig Discarding Data And Disabling Caching Description Discards the data on the cache and disable caching on the specified fluid cache disk Syntax omconfig storage fluidcachedisk action disablewithdiscard fluidcachedisk lt string gt Example to Discard the data on the cache and disable caching on the fluid cache disk fcd1 Example omconfig storage fluidcachedisk action disablewithdiscard fluidcachedisk fcdl 191 192 9 Working With CLI Command Results Server Administrator Command Line Interface CLI users can use the command output in various ways This chapter explains how to save command output to a file and how to select a format for the command results that fits different objectives The following table displays the systems on which omreport commands are applicable Table 125 System Availability For The omreport Command Command Level 1 Command Level 2 Applicable To omreport modularenclosure Blade systems servermodule Blade systems mainsystem Blade systems system Rack and Tower systems chassis Rack and Tower systems Output Options For Command Results CLI command output displays to standard output on the system in a command window in an X terminal or on a screen depending on the type of the operating system You can redirect command results to a file instead of displaying them to standard output Saving command output to a file allows you to use the comma
175. on set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to the same name value pair 1 For an example see Example Command For Adding Acquisition Information 128 6 Using The Storage Management Service The CLI of Storage Management enables you to perform reporting configuration and management functions of Storage Management from an operating system command shell The Storage Management CLI also enables you to script command sequences The Storage Management CLI provides expanded options for the Dell OpenManage Server Administrator omreport and omconfig commands E NOTE For more information see the Dell OpenManage Server Administrator Installation Guide and Dell OpenManage Management Station Software Installation Guide For more information on Storage Management see the Storage Management online Help or the Dell OpenManage Server Administrator Storage Management User s Guide CLI Command Syntax Like all Server Administrator commands the omreport and omconfig command syntax consists of specifying command levels The first command level is the command name omreport or omconfig Subsequent command levels provide a greater degree of specification regarding the type of object on which the command operates or the information that the command displays For example the following omconfig command sy
176. onents at one time or get details about a specific component This chapter shows you how to get reports with the level of detail that you want Commands documented in this chapter vary in whether they define the fields that appear in the results of a particular omreport command The fields are defined only if they have a special or less familiar use As with all other components use omreport to view component status and omconfig to manage a component For information on configuring components for management see omconfig Managing Components Using The Instrumentation Service Use the omreport commands to get information you need to execute an omconfig command For example to edit the minimum temperature for a warning event on a temperature probe you must know the index of the probe you want to configure Use omreport chassis temps to display a list of probes and their indexes The omreport commands available on the system depend on the system configuration The following table lists the systems on which the omreport commands are applicable Table 3 System Availability For The omreport Command Command Command Applicable To Level 1 Level 2 omreport modularenclos Blade systems ure servermodule Blade systems mainsystem Blade systems system Rack and Tower systems chassis Rack and Tower systems preferences Blade or Rack and Tower systems Conventions For Parameter Tables When listing the parameters that a command can take t
177. onfig sysname config syspower config servicetag name value pair 2 NA NA NA NA config remoteaccessip NA v4 config remoteaccessip NA v6 config remoteaccessm NA ac config ipv4idrac config ipv6idrac config macidrac config ambienttemp security modify security view security disabled NA NA NA NA remoteindication true NA Description true Enables the Power button on the system e false Disables the Power button on the system Sets the name of the system Sets the system power information Sets the system service tag information Sets the remote access IPv4 information Sets the remote access IPv6 information Sets the remote access MAC address Sets IPv4 DRAC information Sets IPv6 DRAC information Sets the DRAC s MAC address Sets the system temperature in centigrade Allows you to modify the LCD text Provides read only access to the LCD text Provides limited access to the LCD text LCD flashes when the system detects an active remote session K NOTE The options ipv4idrac ipv6idrac and macidrac are deprecated Omconfig Chassis Info Or Omconfig Mainsystem Info Use the omconfig chassis info or omconfig mainsystem info command to enter an asset tag name and a chassis name for the system For a blade systems enter asset tag names for modular components as well The following table displays the valid parameters for the command Table 25 Valid Parameters Of Omconfi
178. onfig system assetinfo or omconfig servermodule assetinfo command For more information see Omconfig System Or Servermodule Assetinfo Editing Cost Of Ownership Values Omreport System Events Or Omreport Servermodule Events Use the omreport system events or omreport servermodule events command to view the currently enabled or disabled SNMP traps Type omreport system events or omreport servermodul vents This command displays a summary of each component in the system for which events are generated For each component the report shows which severities are set to report and which severities are set not to report The following is an example output for a few components Current SNMP Trap Configuration Settings Enable Informational Warning and Critical Disable None Settings Enable Informational Warning and Critical Disable None Settings Enable Critical 48 Disable Informational Warning and Critical Settings Enable Informational Warning and Critical Disable None The full report lists the settings for all components in the system for which events are generated Omreport System Events Type Or Omreport Servermodule Events Type To view the status for components of a specific type use the omreport system events type component name gt or omreport servermodule event type component name command Type omreport system events type fans or omreport servermodul vents type fans This
179. operating system and initiates system startup performing BIOS checks and reloading the operating system action poweroff Turns off electrical power to the system action powercycle Turns off electrical power to the system pauses turns the power on and reboots the system Power cycling is useful when you want to re initialize system components such as hard drives timer lt n gt Number of seconds that must pass before the system is considered to have a hung operating system from 20 seconds to 480 seconds Example Recovery Commands To set the action on hung operating system detection to powercycle type omconfig system recovery action powercycle or omconfig servermodule recovery action powercycle To set the system to hang for 120 seconds before a recovery action is initiated type omconfig system recovery timer 120 or omconfig servermodule recovery timer 120 Omconfig System Shutdown Or Omconfig Servermodule Shutdown Use the omconfig system shutdown or omconfig servermodule shutdown command to determine the way in which the system shuts down During system shutdown the default is to shut down the operating system before powering off the system Shutting down the operating system first closes down the file 113 system before powering the system down If you do not want to shut down the operating system first use the osfirst false parameter The following table displays the valid parameters for the comman
180. or creating a virtual disk has several parameters You must specify the following parameters e Controller controller id e RAID level raid lt c rO r1 r1c r5 r6 r10 r50 r60 gt e Size size lt number max min gt gt Physical disk is specified as either e For SCSI SATA and ATA controllers pdisk connector enclosureID targetID 166 where connector enclosurelD targetlD is the connector number enclosure number and slot number For SAS controllers pdisk connector targetID where connectorlD targetlD is the connector number and the slot number For example pdisk 0 2 Storage Management supplies default values for any of the other parameters that you do not specify For creating an encrypted virtual disk specify secureflag yes You can create encrypted virtual disks only with SED drives Complete Syntax omconfig storage controller action createvdisk controller id raid c r0 rl ric r5 r6 r10 r50 r60 gt size lt number max min pdisk lt PDISKID gt stripesize stripesize 2kb 4kb 8kb 16kb 32kb 64kb 128kb gt cachepolicy d c gt diskcachepolicy lt disabled nabled gt readpolicy lt ra nra ara rc nrc gt writepolicy wb wt wc nwc fwb gt name lt string gt spanlength lt n gt secureflag yes vdpienabled yes Es NOTE If you are configuring RAID for SAS controllers with firmware version 6 1 and later spanlength is an optional paramet
181. orage globalinfo Optional name value pairs Use Displays whether smart thermal shutdown is enabled or disabled For more information see Omconfig Global Enable Smart Thermal Shutdown Displays the hot spare protection policy that you have set For more information on setting hot spare protection policy see the Dell 139 Required Command Levels 1 Optional name value pairs Use 2 3 OpenManage Server Administrator Storage Management User s Guide at dell com support manuals Omreport Connector Status The following table describes the syntax for the omreport Connector commands Table 76 Omreport Connector Commands Required Command Levels 1 2 Optional name value pairs Use omreport storage connector Displays all connectors present on all controllers on the system NOTE This command works only when the controller ID is specified controller id where id is the Displays the connectors on the controller number For specified controller example controller 0 controller id connector id Displays the specified connector where id is the connector NOTE When the connectors are number For example connected to the enclosure in connector 0 redundant path mode the Name of the connector is displayed as Logical Connector Omreport Cachecade Status The following table describes the syntax for the omreport Cachecade commands Table 77 Omreport Cachecade Commands Required Command Levels Optional name value
182. oreignconfig controller id passphrase lt passphrase string for the foreign configuration gt where id is the controller ID as reported by the omreport storage controller command Unlock the ecncrypted LKM configuration drives on controller 1 omconfig storage controller action importsecureforeignconfig controller 1 passphrase Dell_123 Omconfig Import Foreign Configuration Descriptio n Syntax Example to Example Imports all virtual disks that reside on physical disks newly attached to the controller omconfig storage controller action importforeignconfig controller id where id is the controller ID as reported by the omreport storage controller command Es NOTE This command is supported only in firmware version 5 0 x Import foreign configurations on controller 1 omconfig storage controller action importforeignconfig controller 1 Omconfig Import Or Recover Foreign Configuration Descriptio n Syntax Example to Example Imports and recovers all virtual disks that reside on physical disks newly attached to the controller omconfig storage controller action importrecoverforeignconfig controller id where idis the controller ID as reported by the omreport storage controller command K NOTE This command is supported only in firmware version 5 1 1 Import foreign configurations on controller 1 omconfig storage controller action importrecoverforeignconfig controller 1 Omconfig Clear Foreign Conf
183. ory board or module in the system for example the system board or the memory module in a given slot number Location e Use e Installed Capacity e Maximum Capacity e Slots Available e Slots Used e ECC Type BIOS e Manufacturer 56 e BIOS Version e Release Date Firmware e Name e Version Network Data The following details are listed for each NIC and Team interface if Team interface is configured in the system e P Address e Subnet Mask e Default Gateway MAC Address Storage Enclosures The following details are listed for each storage enclosure attached to the system Name e Service Tag Omreport System Thrmshutdown Or Omreport Servermodule Thrmshutdown Use the omreport system thrmshutdown or omreport servermodule thrmshutdown command to view the properties configured for a thermal shutdown action The three properties that display for thermal shutdown are disabled warning or failure If the CLI displays the following message the thermal shutdown feature has been disabled Thermal protect shutdown severity disabled If the system is configured to shutdown when a temperature probe detects a warning or failure event one of the following messages is displayed Thermal protect shutdown severity warning Thermal protect shutdown severity failure Omreport System Version Or Omreport Servermodule Version Use the omreport system version or omreport servermodule version command to list the versio
184. osure Asset Name Table 108 Omconfig Set Enclosure Asset Name Description Syntax Example to Specifies the asset name for an enclosure omconfig storage enclosure action setassetname controller id enclosure ENCLOSUREID assetname lt string gt where id is the controller ID The lt ENCLOSUREID gt variable specifies the enclosure In this syntax lt string gt is a user specified alphanumeric string Specify the asset name to encl43 for the enclosure attached to connector 2 on controller 1 181 Example for SCSI SATA and ATA controllers Example for SAS controllers omconfig storage enclosure action setassetname controller 1 enclosure 2 assetname encl43 omconfig storage enclosure action setassetname controller 1 enclosure 1 2 assetname encl43 Omconfig Set Temperature Probe Thresholds Table 109 Omconfig Set Temperature Probe Thresholds Description Syntax Example to Example for SCSI SATA and ATA controllers Sets the minimum and maximum warning temperature thresholds for a specified temperature probe K NOTE This command is not supported on SAS controllers omconfig storage enclosure action settempprobes controller id enclosure lt ENCLOSUREID gt index id minwarn n maxwarn n where id is the controller ID and the temperature probe ID The lt ENCLOSUREID gt variable specifies the enclosure In this syntax n is a user specified alphanumeric string Set the tempe
185. ou may notice the following output Removable Flash Media Information Health Critical Internal Dual SD Module Redundancy y Critical Attribute Redundancy Value Lost Internal SD Modules Status Status OK Connector Name System Board SD Status 1 State Present Storage Size 512 MB Status ar OK Connector Name System Board SD Status 2 State Present Storage Size 512 MB VFlash Media Details Connector Name System Board SD Status 1 Type vFlash SD Card 43 State Present Available Size 472 MB Storage Size 512 MB Omreport Chassis Slots Or Omreport Mainsystem Slots Use the omreport chassis slots or omreport mainsystem slots command to view properties of the system s slots Type omreport chassis slots index n or omreport mainsystem slots index n The index parameter is optional If you do not specify the index Server Administrator displays properties for all of the slots in the system If you specify the index Server Administrator displays properties for a specific slot NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable For each slot in the system values display for the following fields given in the following table Table 13 Valid Parameters Of Omreport Chassis Slots Or Omreport Mainsystem Slots Field Description Index Number of the slot in the system Slot ID Silk screen name printed on the system s
186. p a list of the main CLI commands is displayed 15 The next level of complexity includes commands that contain command levels 1 and 2 All of the about commands are examples of command level 2 complexity The omconfig about and omreport about commands display a very brief summary The summary shows version information for the systems management software installed on the system for example Server Administrator 1 x Some commands have command level 1 and command level 2 and one name value pair Consider the following example command that instructs Server Administrator for more details about the environment for Server Administrator omreport about details true In this example command level 1 is omreport command level 2 is about and the name value pair is details true Many commands use command level 1 command level 2 and command level 5 but do not require any parameters name value pairs Most omreport commands are of this type For example the following command displays a list of alert actions that are configured for components on a system omreport system alertaction The most complex commands have all three command levels and can have multiple name value pairs The following is an example of two name value pairs omconfig system assetinfo info depreciation duration 3 The following is an example of nine name value pairs omconfig system assetinfo info acquisition purchasecost n waybill n installdate lt mmddyy gt pu
187. pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Cancel replace member operation on disk 0 0 1 which is connected to controller O omconfig storage pdisk action cancelreplacemember controller 0 pdisk 0 0 1 Clears data or a configuration from a physical disk omconfig storage pdisk action clear controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Clear physical disk 5 on connector 0 of controller 1 On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action clear controller 1 pdisk 0 2 3 Cancels a clear operation in progress on a physical disk omconfig storage pdisk action cancelclear controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk Example to Example for SCSI SATA and ATA controllers Omconfig Enable Device Write Cache Description S
188. ple to Start the learn cycle on controller 1 Example omconfig storage battery action startlearn controller 1 battery 0 Omconfig Delay Battery Learn Cycle Table 116 Omconfig Delay Battery Learn Cycle Description Delays the battery learn cycle for a specified period of time You can delay the battery learn cycle for a maximum of seven days or 168 hours Syntax omconfig storage battery action delaylearn controller id battery id days d hours h where id is the controller ID and battery ID as reported by the omreport command To obtain this value type omreport storage controller to display the controller IDs and then type omreport storage battery controller ID to display the ID for the controller battery Example to Delay the learn cycle for three days and 12 hours on controller 1 Example omconfig storage battery action delaylearn controller 1 battery 0 days 3 hours 12 Omconfig Global Commands The following table displays the omconfig command syntax required to execute the global commands When executed these commands apply to all controllers These global commands also correspond to the global tasks provided by the Storage tree view object s Information Configuration subtab 184 Table 117 Omconfig Global Commands Required Command Optional name value pairs Levels 1 2 3 omconfig storage action enablests globalinfo action disablests action globalrescan action setprotectionpolicies type ghs or dhs Omconfig Global Enable S
189. port Chassis Pwrmanagement Or Omreport Mainsystem Pwrmanagement 39 Omreport Chassis Pwrmonitoring Or Omreport Mainsystem Pwrmonitoring 40 Omreport Chassis Pwrsupplies Or Omreport Mainsystem Dwrsupplles 42 Omreport Chassis Remoteaccess Or Omreport Mainsystem RemoteaccCess 42 Omreport Chassis Removableflashmedia Or Omreport Mainsystem Removableflaslimedia saci ecd e e N SIA EAT Od ees Omreport Chassis Slots Or Omreport Mainsystem Slots Omreport Chassis Temps Or Omreport Mainsystem Temps Omreport Chassis Volts Or Omreport Mainsystem Volt Omreport Licenses piede er Pre etn te oL OI ned EG Ee Te edere pais Omreport System Commands Or Omreport Servermodule Commandes Omreport System Or Omreport Servermodule Commands For Viewing Loge Omreport System Alertaction Or Omreport Servermodule Alertaction sss Omreport System Assetinfo Or Omreport Servermodule Assetinfo ssssssss Omreport System Events Or Omreport Servermodule Events Omreport System Events Type Or Omreport Servermodule Events Tvpe Omreport System Operatingsystem Or Omreport Servermodule Operatingsystem 50 Omreport System Pedestinations Or Omreport Servermodule Pedestinations 50 Omreport System Platformevents Or Omreport Servermodule Platformevents 51 Omreport System Recovery Or Omreport Servermodule RecCover 52 Omreport System Shutdow
190. pports and for general information about RAID levels and concatenation see the Dell OpenManage Online Help The following table displays how to specify the raid n parameter for each RAID level and concatenation 170 Table 98 Raid Level And Concatenation RAID Level or Concatenation raidzn Parameter Specification RAID O raid r0 RAID 1 raid r1 RAID 5 raid r5 RAID 6 raid r6 RAID 10 raid r10 RAID 50 raid r50 RAID 60 raid r60 RAID 1 concatenated raid r1c Concatenation raid c size lt number max min gt Parameter The following table displays how to specify the size lt number max min gt Table 99 Size Parameter size lt number max min gt Parameter Description Specification size lt n gt Use this specification to indicate a specific size for the virtual disk The virtual disk size is specified in b bytes m megabytes or g gigabytes For example size 500m indicates that the virtual disk is 500 MB size max To create a virtual disk that is the maximum size possible specify size max When creating a RAID 50 virtual disk this parameter is specified as size max size min To create a virtual disk that is the minimum size possible specify size min stripesize lt 2kb 4kb 8kb 16kb 32kb 64kb 128kb gt stripesize lt 2kb 4kb 8kb 16kb 32kb 64kb 128kb gt Different controllers support different stripe sizes For more information on stripe sizes supported for a controller
191. q OneTimeCustomBootSegStr OneTimeCustomHddSegStr OneTimeCustomUefiBootSeqStr sequence aliasnamel aliasname2 aliasnameN sequence aliasnamel aliasname2 aliasnameN sequence aliasnamel aliasname2 aliasnameN Group Processor Settings name value pair 1 attribute attribute DataReuse attribute DculpPrefetcher attribute DcuStreamerPrefetch er attribute LogicalProc attribute Proc1Brand attribute Proc1ld attribute Proc1L2Cache attribute Proc1L3Cache attribute ProciNumCores attribute Proc2Brand attribute Proc2ld attribute Proc2L2Cache attribute Proc2L3Cache attribute Proc2NumCores attribute Proc3Brand attribute Proc3ld attribute Proc3L2Cache attribute Proc3L3Cache attribute Proc3NumCores attribute Proc4Brand attribute Proc4ld attribute Proc4L2Cache attribute Proc4L3Cache attribute Proc4NumCores attribute Proc64bit attribute ProcAdjCacheLine attribute ProcBusSpeed attribute ProcCores attribute ProcCoreSpeed attribute ProcExecuteDisable attributez ProcHwPrefetcher name value pair 2 setting setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti setti 10 setti setti sett ng Enabled ng Enabled ng Enabled ng Enabled ng lt string gt ng lt string gt ng lt string gt ng lt string gt ng lt in
192. r 1 Description advanced ECC advecc Enables the two DRAM controllers to combine in 128 bit mode and provide optimized reliability Memory that are not teamed by the controllers is not reported to the operating system Omconfig Chassis Pwrmanagement Or Omconfig Mainsystem Pwrmanagement Use the omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement command to configure power cap and manage profiles that control power utilization Es NOTE This command is valid only on systems prior to PowerEdge 12G systems The following table displays the valid parameters for the command Table 28 Valid Parameters Of Omconfig Chassis Pwrmanagement Or Omconfig Mainsystem Pwrmanagement name value pair 1 config budget config profile Es NOTE This option is supported on systems prior to PowerEdge 12G systems 88 name value pair 2 cap lt value gt setting enable disable unit watt btuphr percent profile maxperformance apc osctrl custom Description Sets the threshold value for power budget K NOTE From PowerEdge 12G system onwards power budget requires license to configure power cap If the appropriate license is not installed or has expired the system displays an error message For more information see Dell License Manager at dell com support manuals enable Enables powercap settings disable Disables powercap settings watt Configure the unit in Watts btuphr
193. r Setting Alert Actions Setting an alert action requires two name value pairs The first name value pair is the event type The second name value pair is the action to take for this event For example in the command omconfig system alertaction event powersupply broadcast true or omconfig servermodule alertaction event powersupply broadcast true The event is a power supply failure and the action is to broadcast a message to all Server Administrator users Available Alert Actions The following table displays the alert actions for each component that allows you to configure an alert action Table 39 Valid Parameters of Alert Actions For Warning and Failure Events Alert Action Setting Description alert true false true Enables the system s console alert When enabled the monitor attached to the system from which you are running Server Administrator displays a visual alert message false Disables the system s console alert broadcast true false true Enables a message or alert to broadcast to all users who have an active terminal or Remote Desktop session Windows or to operators that have an active shell on the local system Linux false Disables alert broadcasts clearall true Clears all actions for this event execappath lt string gt Sets the fully qualified path and file name of the application you want to execute in case of an event for the component described in this window K NOTE On Linux systems
194. r and Power User privileges are sufficient to use the omreport storage command 131 132 Omreport Storage Commands The omreport command allows you to view storage component information for disks controllers enclosures batteries global storage properties connectors and cachecades that are part of the storage system The omreport command helps to get reports with the level of detail that you want The commands may vary in whether they define the fields that appear in the results of a particular omreport command Fields are defined only if they have a special or less familiar use The following sections provide the omreport command syntax required to display the information of various storage components To see a list of valid commands for omreport storage type omreport storage The following table provides the omreport storage command syntax Table 64 Omreport Storage Help Command Command Command Use Level 1 Level 2 Level 3 omreport storage Displays a list of storage components for which omreport commands are available pdisk Displays a list of the omreport storage pdisk parameters for displaying physical disk information vdisk Displays a list of omreport storage vdisk parameters for displaying virtual disk information controller Displays a list of the omreport storage controller parameters for displaying controller information enclosure Displays a list of the omreport storage enclosure parameters for displa
195. r omconfig servermodule extwarranty command to assign values for extended warranty information A warranty is a contract between the manufacturer or dealer and the purchaser of a system The warranty identifies the components that are covered for repair or replacement for a specified length of time or usage The extended warranty comes into force after the original warranty expires For details on how to edit warranty values see Adding Warranty Information The following table displays the valid parameters for the command Table 53 Valid Parameters Of omconfig system assetinfo info extwarranty Or omconfig servermodule assetinfo info extwarranty Command Command Command Name Value Name Value Pair 2 Description Level 1 Level 2 Level 3 Pair 1 omconfig system or assetinfo info extwarran cost cost Cost of the servermodule ty extended warranty service enddate lt enddate gt Date the extended warranty agreement ends provider lt provider Business entity that gt provides the extended warranty service startdate lt startdate Date the extended gt warranty service begins 120 Example Command For Adding Extended Warranty Information To provide a value for an extended warranty parameter type a command of the form omconfig system assetinfo info extwarranty lt name value pair 2 or omconfig servermodule assetinfo info extwarranty lt name value pair 2 For example type omconfig system assetinfo info extwarranty enddate
196. r power consumption probe warning threshold values to the recommended default value type omconfig chassis pwrmonitoring config probe index 0 warnthresh settodefault or omconfig mainsystem pwrmonitoring config probe index 0 warnthresh settodefault You cannot default one value and set another If you default the minimum warning threshold value you are also selecting the default value for the maximum warning threshold value Specify A Value For Warning Thresholds If you prefer to specify values for the power consumption probe warning thresholds you must specify the number of the probe you are configuring and the warning threshold value Configure the values to display either in BTU hr or Watts In the following example the probe that is being configured is probe 4 omconfig chassis pwrmonitoring config probe index 4 warnthresh 325 unit watt or omconfig mainsystem pwrmonitoring config probe index 4 warnthresh 325 unit btuphr When you issue the command and the system sets the values you specify the following message is displayed Power consumption probe warning threshold s set successfully 90 Omconfig Chassis Remoteaccess Or Omconfig Mainsystem Remoteaccess Use the omconfig chassis remoteaccess or omconfig mainsystem remoteaccesscommand to configure e Remote access on a local area network LAN e The serial port for BMC or RAC whichever is installed e The BMC or RAC on a serial over LAN connection Terminal setti
197. rature probe thresholds to 10 and 40 degree Celsius omconfig storage enclosure action settempprobes controller 1 enclosure 2 index 3 minwarn 10 maxwarn 40 K NOTE Here temperature probe 3 resides in the enclosure attached to connector 2 on controller 1 Omconfig Reset Temperature Probe Thresholds Table 110 Omconfig Reset Temperature Probe Thresholds Description Syntax Example to Example for SCSI SATA and ATA controllers 182 Resets the minimum and maximum warning temperature thresholds back to their default values K NOTE This command is not supported on SAS controllers omconfig storage enclosure action resettempprobes controller id enclosure ENCLOSUREID index id where idis the controller ID and the temperature probe ID The lt ENCLOSUREID gt variable specifies the enclosure In this syntax n is a user specified alphanumeric string Reset the thresholds for temperature probe 3 residing in the enclosure attached to connector 2 on controller 1 to the default values omconfig storage enclosure action resettempprobes controller 1 enclosure 2 index 3 K NOTE Here temperature probe 3 resides in the enclosure attached to connector 2 on controller 1 Omconfig Set All Temperature Probe Thresholds Table 111 Omconfig Set All Temperature Probe Thresholds Description Syntax Example to Example for SAS controllers Sets the minimum and maximum warning temperature thresholds
198. rchasedate mmddyy ponum lt n gt signauth lt text gt expensed lt yes gt no gt costcenter lt text gt In each chapter of this document command syntax and other information about the commands are formatted using any of the following fields as appropriate command level 1 command level 2 command level 3 name value pair1 name value pair 2 16 2 Using The omhelp Command The omhelp command and its equivalent lt command gt accesses the detailed help text interface of Command Line Interface CLI You can get help at several levels of detail Each fully qualified CLI command may have a variable number of distinct parts the command command level 1 one or more subcommands command level 2 and command level 3 if present and one or more name value pair s By appending space dash question mark to any command you can get help for that command Example Help Commands When you type omconfig you get general help about the omconfig command The help at this level lists the available subcommands for omconfig e about e preferences e chassis e system When you type omconfig system the CLI help lists all the subcommands available for omconfig system e alertaction e alertlog e assetinfo e cmdlog e esmlog e events e platformevents e pedestinations recovery e shutdown e thrmshutdown e webserver Also parse the omconfig system assetinfo command as follows command level 1 command leve
199. re and execute system shutdown e Power user and administrator privilege to specify values for warning events on fans voltage probes and temperature probes e Power user and administrator privilege to set alert actions in case of a warning or failure event from intrusion fans voltage probes and temperature probes For more information on using the omconfig command to view and manage cost of ownership information assetinfo see Omconfig System Or Servermodule Assetinfo Editing Cost Of Ownership Values Often you must use the omreport commands to get the information required to execute an omconfig command For example to edit the minimum temperature for a warning event on a temperature probe you must know the index of the probe Use the omreport chassis temps or omreport mainsystem temp command to display a list of probes and their indexes For more information on using the omreport command see Omreport Viewing System Status Using The Instrumentation Service The following table displays the system availability for the omconfig command Table 18 System Availability For The Omconfig Command Command Level 1 Command Level 2 Applicable to omconfig servermodule Blade systems mainsystem Blade systems system Rack and Tower systems chassis Rack and Tower systems Conventions For Parameter Tables When listing the parameters that a command can take the parameters are listed in alphabetical order instead of the order in which they app
200. reconfigured virtual disk and to any new physical disks being added to the reconfigured virtual disk Some controllers allow you to remove a physical disk from a virtual disk In this case do not specify to remove the physical disk The pdisk lt PDISKID gt parameter indicates a physical disk by specifying either connector enclosurelD targetID or connector targetID stripesize lt 2kb 4kb 8kb 16kb 32kb 64kb 128kb gt Different controllers support different stripe sizes For more information on stripe sizes supported for a controller see the Dell OpenManage Online Help All stripe sizes are specified in kilobytes For example when specifying 128 KB as the stripe size type stripesize 128kb cachepolicy lt d c gt parameter Different controllers support different cache policies The following table displays how to specify the cachepolicy lt d c gt parameter for each of the cache policies Table 94 Cache Policy Parameters Cache Policy cachepolicy d c Parameter Specification Direct I O cachepolicy d Cache I O cachepolicy c diskcachepolicy lt disabled enabled gt Different controllers support different disk cache policies The following table indicates how to specify the diskcachepolicy lt disabled enabled gt parameter for each of the cache policies 169 Table 95 Disk Cache Policy Parameters Disk Cache Policy diskcachepolicy disabled enabled Parameter Specification Disabled diskcachepolicy disabled
201. report storage vdisk controller ID to display the IDs for the virtual disks attached to the controller For more information about the controller specific diskcache read write and cache policy see the Dell OpenManage Online Help For information on specifying these parameters using the omconfig command see the following e readpolicy lt ra nra ara rc nrc parameter optional e writepolicy lt wb wt wc nwc fwb parameter optional e cachepolicy lt d c gt Parameter optional e diskcachepolicy lt enabled disabled gt parameter optional Change the read policy of virtual disk 4 on controller 1 to no read ahead omconfig storage vdisk action changepolicy controller 1 vdisk 4 readpolicy nra Omconfig Replace Member Virtual Disk Description Syntax Example to Example for SCSI SATA and ATA Ccntrollers Example for SAS controllers Replaces the member of a given virtual disk with the destination disk omconfig storage vdisk action replacememberdisk controller id vdisk id source lt PDISKID gt destination lt PDISKID gt where id is the controller ID and virtual disk ID as reported by the omreport command The lt PDISK gt variable specifies the physical disk K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Replace physi
202. ription Syntax Example to Example Formats a virtual disk omconfig storage vdisk action format controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controllerzID to display the IDs for the virtual disks attached to the controller Format virtual disk 4 on controller 1 omconfig storage vdisk action format controller 1 vdisk 4 Omconfig Reconfiguring Virtual Disks Description Syntax Reconfigures a virtual disk to change the virtual disk s RAID level or increase its size by either adding physical disks or using the available free space On some controllers you can also remove physical disks K NOTE If you want to reconfigure with an additional physical disk the physical disk must be of the supported bus protocol media type sector size T10 Protection Information capability and encryption capability omconfig storage vdisk action reconfigure controller id vdisk id raid lt c r0 rij ric r5 rel r10 pdisk lt PDISK gt size size vdcapacityexpansion yes sizeinpercent 1 to 1002 where id is the controller ID and virtual disk ID as reported by the omreport command 159 Example to Example for SCSI SATA and ATA controllers Example for SAS controllers Example to Example K NOTE To obtain these val
203. rmance Management and Fan Power and Performance Management 39 The following is an example output Power Inventory and Budget Power Inventory System Idle Power 92 W System Maximum Potential Power 344 W Power Budget Attribute Enable Power Cap Values Enabled Attribute Power Cap Values 400 W 562 NOTE Power budget requires license to report the details If the appropriate license is not installed or has expired the system does not display the power budget details For more information see the Dell License Manager Guide at dell com support manuals Omreport Chassis Pwrmonitoring Or Omreport Mainsystem Pwrmonitoring Use the omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command to view the properties of the system s power consumption The values display either in Watts or BTU Hr based on the configuration Type omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring For each power monitoring profile in the system values display for the following fields 40 Power Consumption Status Probe Name Reading Warning Threshold Failure Threshold Amperage Location and Reading Power Tracking Statistics Energy Consumption Measurement Start Time Measurement Finish Time Reading System Peak Power System Peak Amperage E NOTE The omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command is applicable from PowerEdge 10G system onwards that s
204. roller 1 enclosure 1 2 Omconfig Disable Enclosure Alarm Table 106 Omconfig Disable Enclosure Alarm Description Syntax Example to Example for SCSI SATA and ATA controllers Example for SAS controllers Disables the enclosure alarm omconfig storage enclosure action disablealarm controller id enclosure lt ENCLOSUREID gt where idis the controller ID The lt ENCLOSUREID gt variable specifies the enclosure Disables the alarm on enclosure 2 attached to connector 1 on controller 1 omconfig storage enclosure action disablealarm controller 1 enclosure 2 omconfig storage enclosure action disablealarm controller 1 enclosure 1 2 Omconfig Set Enclosure Asset Tag Table 107 Omconfig Set Enclosure Asset Tag Description Syntax Example to Example for SCSI SATA and ATA controllers Example for SAS controllers Specifies the enclosure s asset tag omconfig storage enclosure action setassettag controller id enclosure ENCLOSUREID assettag lt string gt where idis the controller ID The ENCLOSUREID variable specifies the enclosure In this syntax string is a user specified alphanumeric string Specify the asset tag to encl20 on the enclosure attached to connector 2 on controller omconfig storage enclosure action setassettag controller 1 enclosure 2 assettag encl20 omconfig storage enclosure action setassettag controller 1 enclosure 1 2 assettag enc120 Omconfig Set Encl
205. roller 1D to display the IDs for the virtual disks attached to the controller Pause a check consistency on virtual disk 4 on controller 1 omconfig storage vdisk action pausecheckconsistency controller 1 vdisk 4 Omconfig Resume Check Consistency Description Syntax Example to Example Resumes a check consistency after it has been paused omconfig storage vdisk action resumecheckconsistency controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controllerzID to display the IDs for the virtual disks attached to the controller Resume a check consistency on virtual disk 4 on controller 1 omconfig storage vdisk action resumecheckconsistency controller 1 vdisk 4 155 Omconfig Blink Virtual Disk Description Syntax Example to Example Blinks the physical disks included in a virtual disk omconfig storage vdisk action blink controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controllerzID to display the IDs for the virtual disks attached to the controller Blink the physical disks in virtual disk 4 on controller 1 omconfig storage v
206. roller Status anes eee wien S RE C RH ER HV acon 155 Otrireport Enclosure Statusii ss ten ce tdi deter erdum e ee eene sa Dev dues 155 Omreport Temperature Probe Status 136 OmreportiFan Status c te E 136 Omreport Power Supply Siatus cecceecccescceeceeeeeneeeeeeceeneeeeeeeneeeeeeneeseeesceesneesieseteeeiteseeneetaes 137 mreport EMM Status 3 exte tU Del iet TR TH 138 Omreport Enclosure Slot Occupancy Report 138 Omteport Battery atinada ee dente aie ait ti Ain Wola die abad aia 139 Omreport Global ntormationvss u or tot tcov ATEOS Se 139 Otrireport Connector Status iei ti EE 140 QOmireport Cachecade Status ate eet lr ore cu ust Da UE dle 140 Omnmireport PCle SSD Status z ede e derer dee Denda d dan reir eee d adden 140 Omtreport Fluid Cache Status oho eere eti rei detenti besten eaten es 141 Omreport Fluid Cache Pool Status bo bett net etre db e nh rg c e HU toad 141 Omreport Partition Stats s 452 n tree i e o EE 141 Omreport Fl id Cache Bisk Status az gei eda e ih dere cie c een seen ite 141 Qmrepotrt Storagesl apex ceret dond add En Eea ca eins SUA e teem ei Ed rccte ep c E teed 142 8 Omconfig Storage Commandes 143 Omconfig Physical Disk Comnm tnds siot e n Ee 144 Omeconfig Blink Physical DISK tet eee b t ette com Foe esce to de o attends 144 Ornmcohfig Unblink Physical DISK sass anette e e eee id 145 Omconfig Prepare To Remove Physical Disk 145 Omconfig Instant Erase Secured Physical Disk 146 Omconfig Cryptographic
207. rovide a value for a maintenance parameter type a command of the form omconfig system assetinfo info maintenance lt name value pair 2 gt or omconfig system assetinfo info maintenance lt name value pair 2 gt For example type omconfig system assetinfo info maintenance startdate 012504 or omconfig servermodule assetinfo info maintenance startdate 012504 122 The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to the same name value pair 1 For an example see Example Commands For Adding Acquisition Information Adding Outsource Information Outsourcing is the practice of contracting with another business to maintain the system in good working order The following table displays the valid parameters for adding outsource information Table 56 Valid Parameters Of omconfig system assetinfo info outsource Or omconfig servermodule assetinfo info outsource Comman Command Command Name Name Value Pair 2 Description dLevel1 Level2 Level 3 Value Pair 1 omconfig system or assetinfo info outsour levels lt n gt Levels of service servermodul ce that the provider e offers problemcomponent comp System onent gt component that requires maintenance providerfee lt providerfee gt Amount of money charged for maintenance servi
208. rt Enclosure Slot Occupancy Report commands Table 73 Omreport Enclosure Slot Occupancy Report Commands Required Command Levels 1 2 Optional name value pairs 3 and name value pair omreport storage enclosure controller id enclosure lt ENCLOSUREID gt info pdslotreport where id is the controller number and ENCLOSUREID is the enclosure number For example controller 0 enclosure 2 Omreport Battery Status Use Displays property information for all enclosures attached to the system Displays the empty and occupied slot details for the specified enclosure NOTE This command is not supported on Blackplane SCSI and SWRAID controllers The following table describes the syntax for the omreport Battery commands Table 74 Omreport Battery Commands Required Command Levels 1 2 Optional name value pairs 3 omreport storage battery controller id where id is the controller number For example controller 0 controller id battery id where id is the controller number For example controller 0 Omreport Global Information Use Displays all batteries present on all controllers on the system Some controllers do not have batteries Displays the battery on the specified controller Displays the specified battery The following table describes the syntax for the omreport Global Information commands Table 75 Omreport Global Information Commands Required Command Levels 1 2 3 omreport st
209. rt storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Encrypt virtual disk 4 on controller 1 omconfig storage vdisk action securevd controller 1 vdisk 4 Omconfig Clear Virtual Disk Bad Blocks Description Syntax Example to Example 160 Clears virtual disk bad blocks omconfig storage vdisk action clearvdbadblocks controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command Es NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controllerzID to display the IDs for the virtual disks attached to the controller Clear bad blocks on virtual disk 4 on controller 1 omconfig storage vdisk action clearvdbadblocks controller 1 vdisk 4 Omconfig Change Virtual Disk Policy Description Syntax Example to Example Changes a virtual disk s read write or cache policy omconfig storage vdisk action changepolicy controller id vdisk id diskcachepolicy lt enabled disabled gt readpolicy lt ra nra ara rc nrc writepolicy lt wb wt wc nwc fwb cachepolicy d c where id is the controller ID and virtual disk ID as reported by the omreport command A NOTE To obtain these values type omreport storage controller to display the controller IDs and then type om
210. rt the foreign configuration and flush the preserved cache to disk To discard preserved cache forcefully either clear the foreign configuration and run the proceeding command or run the proceeding command using force enabled option Omconfig Create Encryption Key Descriptio n Syntax Example to Example 174 Creates the encryption key for the controller omconfig storage controller action createsecuritykey controller id keyid keyid string passphrase lt passphrase string gt escrow yes filepath Absolute path to the escrow file gt Create the encryption key for the controller omconfig storage controller action createsecuritykey controller 1 keyid Dell 123 passphrase Dell 123 escrow yes filepath C escrow xml K NOTE If you set escrow yes specify the escrow file path Omconfig Change Encryption Key Descriptio Changes the encryption key for the controller if passphrase is provided n Syntax Example to Example omconfig storage controller action changesecuritykey controller id keyid lt keyid string gt passphrase passphrase string gt oldpassphrase lt old passphrase string gt escrow yes filepath lt Absolute path to the escrow file gt gt Change the encryption key for the controller omconfig storage controller action changesecuritykey controller 1 keyid Dell 123 passphrase Dell 123 oldpassphrase Dell 321 escrow yes filepath C escrow xml K NOTE If you set escrow yes spe
211. s a summary for a specific voltage probe Omreport Licenses Use the omreport licenses command to view the digital licenses of the hardware devices installed on the system Type omreport licenses The following is an example output from the omreport licenses command Device Index 0 Device Status Ok Device iDRAC7 Device Description iDRAC Device ID DOXXXX License Index 0 Description iDRAC7 Enterprise Evaluation License Status OK Recommended Action N A License Type Evaluation EntitlementID DOXXXX Expiry Date yyyy mm dd hh mm ss Omreport System Commands Or Omreport Servermodule Commands Use the omreport system or omreport servermodule commands to view logs threshold values cost of ownership information and information about how shutdown actions and recovery actions are configured Omreport System Or Omreport Servermodule Use the omreport system or omreport servermodule command to see a general status of the components of the system When you specify a level 5 command such as omreport system shutdown or omreport servermodule shutdown you get detailed information for one system component rather than the high level status obtained with omreport system or omreport servermodule Type omreport system or omreport servermodul 45 If the system has both a main system chassis or main system and at least one direct attached storage device Server Administrator may display a summary tha
212. s for omconfig system alertaction Command Usage Description omconfig system To display the list of valid parameters for omconfig system shutdown shutdown omconfig system To display the list of valid parameters for omconfig system alertaction and to alertaction more scroll the command output one screen at a time Here more allows you to press the spacebar to see the next screen of the CLI help output omconfig system To create a file that contains all the help for the omconfig system alertaction alertaction outa command Here outa directs the output of the command to a file called alert txt alert txt more alert txt To read the help for the alertaction command on Microsoft Windows Red Hat Enterprise Linux or SUSE Linux Enterprise Server operating systems Omconfig About Use the omconfig about command to learn the product name and version number of the systems management application installed on the system The following is an example output of the omconfig about command Product Dell OpenManage Server Administrator name Version Boe Ko Copyright Copyright C Dell Inc xxxx xxxx All rights reserved Company Dell Inc For more details about the environment for Server Administrator type omconfig about details true Server Administrator includes a number of services each having a version number of its own The Contains field reports version numbers for the services and provides other useful de
213. s index 0 Temperature probe warning threshold warnthresh default value s set successfully omconfig chassis biossetup BIOS setup configured successfully attribute numlock setting on Change will tak ffect after the next reboot omconfig system assetinfo omconfig system assetinfo info depreciation duration 6 info depreciation duration 6 NOTE Due to limitations some commands do not alter the system settings even though the commands are executed successfully This is an expected behavior Failure Messages CLI failure messages provide reasons why some commands do not succeed Some common reasons why commands fail include syntax errors and components that are not present Many error messages provide syntax information required to execute the command successfully If you execute a command for a component or feature that is not present in the system configuration the error message states that the component is not present The following are examples of some failure messages 14 Command omconfig chassis volts index 3 minwarnthresh 3 3000 Message Error Number with up to 3 digits after decimal point expected read 3 3000 The value given by the command specifies more than 3 digits after the decimal point A valid minimum warning threshold value for volts contains up to 3 digits after the decimal point Revised command omconfig chassis volts index 3 minwarnthresh 3 300 When you type the revised command with three decimal points
214. see the Dell OpenManage Online Help All stripe sizes are specified in kilobytes For example when specifying 128 KB as the stripe size type stripesize 128kb PDISKID lt connector enclosurelD targetID connector targetID gt PDISKID lt connector enclosurelD targetID connector targetlD Use this parameter to specify the physical disks to be included in the virtual disk When reconfiguring a virtual disk you must specify all physical disks to include in the reconfigured virtual disk The physical disk specification applies to physical disks in the original virtual disk and continues in the reconfigured virtual disk and to any new physical disks being added to the reconfigured virtual disk 171 Some controllers allow you to remove a physical disk from a virtual disk In this case do not specify to remove the physical disk The pdisk lt PDISKID gt parameter indicates a physical disk by specifying either connector enclosurelD targetlD or connector targetlD Cachepolicy lt d c cachepolicy lt d c gt Parameter Different controllers support different cache policies The following table displays how to specify the cachepolicy lt d c gt parameter for each of the cache policies Table 100 Cache Policy Parameters Cache Policy cachepolicy d c Parameter Specification Direct UO cachepolicy d Cache I O cachepolicy c Diskcachepolicy lt disabled enabled gt Different controllers support different disk cache policies Th
215. selected x8xx systems e off Disables serial port 2 e auto Maps serial port 2 to a COM port e com2 Maps serial port 2 to COM port 2 e com4 Maps serial port 2 to COM port 4 on Enables the speaker e off Disables the speaker CPU turbo mode can increase the CPU frequency when the system is operating below the thermal power or current limits enabled Enables CPU Turbo Mode e disabled Disables CPU Turbo Mode e on Enables the user accessible USB port s e backonly Enables only the user accessible USB port s located at the back of the system off Disables the user accessible USB port s enabled Enables the USB port s disabled Disables the USB port s K NOTE Depending on the system s hardware you can configure either usb or usbb e enabled Enables the USB port s during system boot without BIOS support e enabledwithbios Enables the USB port s during system boot with BIOS support e disabled Disables the USB port s during system boot name value pair 1 attribute name value pair 2 setting Description K NOTE Depending on the system s hardware you can configure either usb or usbb attribute cstates setting enabled disabled s enabled Enables th processor to go into a deep sleep state when the system is not utilized e disabled Disables the processor from going into a deep sleep state when the system is not utilized BIOS Setup Set
216. sk resides in enclosure 2 Example for SCSI SATA and ATA controllers Example for SAS controllers Omconfig Initialize Physical Disk Description Syntax Example to Example Omconfig Offline Physical Disk Description Syntax Example to Example for SCSI SATA and ATA controllers Example for SAS controllers omconfig storage pdisk action cryptographicerase controller 1 pdisk 0 3 omconfig storage pdisk action cryptographicerase controller 1 pdisk 0 2 3 Initializes a physical disk omconfig storage pdisk action initialize controller id pdisk id where id is the controller ID and physical disk ID as reported by the omreport command K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Initialize physical disk 4 on controller 1 omconfig storage pdisk action initialize controller 1 pdisk 4 Makes a physical disk offline omconfig storage pdisk action offline controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Offline physical disk 5 on connector 0
217. stem being managed and is accessible both locally and remotely from the Server Administrator home page Server Administrator enables you to access remotely monitored systems by dial in LAN or wireless connections The configuration features enable Server Administrator to perform essential tasks described in detail in the following sections This CLI guide documents all the commands that apply to Server Administrator and Storage Management The reporting and viewing features enable retrieval of the overall health status for systems on the network You can view information about voltage temperature fan s revolutions per minute RPM memory functioning and many other critical details at the component level You can also see a detailed account of the cost of ownership COO about the system retrieve version information about the BIOS firmware operating system and all installed software K NOTE The CLI does not use the Server Administrator Web server For concerns on encryption from the CLI run the omconfig system webserver action stop command to turn off the Web server The Web server starts automatically after a reboot so you must run this command each time the system is rebooted For more information see omconfig system webserver or omconfig servermodule webserver K NOTE After installing Dell OpenManage Server Administrator ensure that you log out and log in to reset the path to access Dell OpenManage CLI utilities K NOT
218. system name value pair 1 attribute attribute cpucore attribute dbs attribute diskette attribute dualnic name value pair 2 setting setting 1 2 4 6 8 10 12 jall setting enable disable setting off auto writeprotect setting off on pxeboth nic1pxe nic2pxe isciboth niclisci nic2isci niclpxenic2isci nicliscinic2pxe onpxeboth onpxenone onpxenict onpxenic2 Description disabled Disables XD support on system 1 Enables one core per processor 2 Enables two cores per processor 4 Enables four cores per processor 6 Enables six cores per processor 8 Enables eight cores per processor 10 Enables ten cores per processor 12 Enables twelve cores per processor all Enables the maximum cores per processor enable Enables Demand Based Switching DBS on the system disable Disables DBS on the system off Disables the diskette drive auto Auto enables the diskette drive writeprotect The diskette drive is available in read only format only Makes the diskette drive read only off Disables the Network Interface Controllers NICs on Enables the network interface PXE or iSCSI is not enabled on either of the NICs pxeboth Enables PXE on both NICs nic1pxe Enables PXE on the first NIC and none no PXE or iSCSI on the second NIC nic2pxe Enables none no PXE or iSCSI on first NIC and PXE on the second NIC isciboth
219. t are present on the system System Information Displays the information that uniquely identifies the system System Profile Settings Controls the power management settings System Security Controls the security features of the system UEFI Boot Settings Controls the system boot settings when boot mode is set to uefi Omreport Chassis Currents Or Omreport Mainsystem Currents This command is no longer available through Server Administrator Omreport Chassis Fans Or Omreport Mainsystem Fans Use the omreport chassis fans or omreport mainsystem fans command to view the fan probe status and settings Type omreport chassis fans index n or omreport mainsystem fans index n The index parameter is optional If you do not specify the index Server Administrator displays a summary of status readings and thresholds set for any fan probes that are present on the system If you specify the index Server Administrator displays a summary for a specific fan probe Omreport Chassis Firmware Or Omreport Mainsystem Firmware Use the omreport chassis firmware or omreport mainsystem firmware command to view current firmware properties When you type omreport chassis firmware or omreport mainsystem firmware Server Administrator displays a summary of the system s firmware properties 30 E NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable E NOTE If
220. t bksp gt or lt del gt is received outputbkspspbksp BMC outputs a lt bksp gt lt sp gt lt bksp gt character when lt bksp gt or del is received enabled Directs the BMC to output a character sequence that indicates when its input buffer is ready to accept another command disabled Does not direct the BMC to output a character sequence that indicates when its input buffer is ready to accept another command cr The console uses CR as a new line sequence null The console uses NULL as a new line sequence enabled Enables line editing as a line is typed disabled Disables line editing as a line is typed none BMC does not use a termination sequence crlf BMC uses lt CR LF gt as a new line sequence when the BMC writes a new line to the console null BMC uses Null as a new line sequence when the BMC writes a new line to the console cr BMC uses CR as a new line sequence when the BMC writes a new line to the console lfcr BMC uses LF CR as a new line sequence when the BMC writes a new line to the console lf BMC uses lt LF gt as a new line sequence when the BMC writes a new line to the console id number ID in numeric format of the user being configured enable true Enables the user enable false Disables the user id number ID in numeric format of the user being configured name value pair 1 config name value pair 2 id number name text id number
221. t is common to all systems is scripted sent to all managed systems and executed Asset information that is unique to a system is scripted as a group and sent to that managed node for execution For example a script could specify values for all unique variables such as the owner primary user phone number asset tag and so on Scripts to populate unique values would set all unique variables at once rather than one by one through the system s command line In many cases the CLI allows a user with a very well defined task in mind to retrieve information about the system rapidly If a user wants to review a comprehensive summary of all system components and save that summary information to a file for comparison with later system states the CLI is ideal Using CLI commands administrators can write batch programs or scripts to execute at specific times When these programs are executed they can capture reports on components of interest such as fan RPMs during periods of highest system usage compared with the same measurements at times of lowest system usage Command results are routed to a file for later analysis Reports can help administrators gain information that are used to adjust usage patterns to justify purchasing new system resources or to focus on the health of a problem component Command Syntax Overview Commands vary in complexity The simplest command has only command level 1 The omhelp command is a simple command When you type omhel
222. t resembles the following example SEVERITY COMPONENT Ok E Main System Chassis Critical Storage Commands For Viewing Logs Use the omreport system or omreport servermodule command to view the following logs the alert log the command log and the hardware or ESM log NOTE If the Alert log or Command log displays invalid XML data such as when XML data generated for the selection is not well formed you must clear the log and resolve the issue To clear the log type omconfig system alertlog action clear oromconfig system cmdlog action clear If you need to retain the log information for future reference save a copy of the log before clearing For more information about clearing logs see Commands For Clearing Logs To view the contents of the alert log type omreport system alertlog or omreport servermodule alertlog To view the contents of the command log type omreport system cmdlog or omreport servermodule cmdlog To view the contents of the ESM log type omreport system esmlog or omreport servermodul smlog Overall Health Status Of The ESM Log When you run the omreport system esmlog or omreport servermodule esmlog command the ESM log is displayed The first line of the report reflects the overall health of the system hardware For example Health OK means that less than 80 percent of the space allotted for the ESM log is occupied by messages If 80 percent or more of th
223. tails The output may change depending on the configuration of the system and the version of Server Administrator Contains Broadcom SNMP Agent 10 xx xx Common Storage Module 3 x x Data Engine 5 x x Hardware Application Programming Interface 5 x x Instrumentation Service 6 x x Instrumentation Service Integration Layer 1 x x Intel SNMP Agent 1 xx x OpenManage Inventory Collector 6 x x OpenManage Tools 6 x x Remote Access Controller 4 Data Populator 4 x x Remote Access Controller 4 Managed Node 4 6 3 65 Secure Port Server 1 x x Server Administrator Framework 6 x x Agent for Remote Access 1 x x Storage Management 3 x x Sun Java Runtime Environment 1 x xx Omconfig Chassis Or Omconfig Mainsystem Use the omconfig chassis or omconfig mainsystem commands to e Set to default or assign specific values for fan voltage and temperature probes e Configure BIOS behavior during system start up e Clear memory error counts e Enable or disable power button control features if the system configuration permits Use the omconfig chassis or omconfig mainsystem command to view a list of all omconfig chassis or omconfig mainsystem commands Omconfig Chassis Biossetup Or Omconfig Mainsystem Biossetup Use the omconfig chassis biossetup or omconfig mainsystem biossetup command to configure system BIOS settings that are normally available only in the BIOS setup boot time settings of the system CAUTION Changing certain BI
224. tects a prefailure value Sets actions when a memory probe detects a failure value Sets actions when a power consumption probe detects peak power value Sets actions when a power consumption probe detects a warning value Sets actions when a power consumption probe detects a failure value Sets actions when a power supply probe detects a failure value Sets actions when a power supply probe detects a warning value Sets actions when a processor probe detects a warning value Sets actions when a processor probe detects a failure value Sets actions when a redundant component becomes inoperative resulting in less than full redundancy for that component Sets actions when one or more redundant components become inoperative resulting in a lost or a no redundant components working condition for that component Sets actions when a temperature probe detects a warning value Sets actions when a temperature probe detects a failure value Sets actions when a voltage probe detects a warning value Sets actions when a voltage probe detects a failure value Sets actions that Server Administrator performs on the next system startup after a watchdog Automatic System Recovery ASR is performed for a hung operating system Sets actions that Server Administrator performs when the system detects a removable flash media Sets actions that Server Administrator performs when a removable flash media is removed Sets actions that Server Admin
225. tects that the processor has failed Sets action or enables or disables alert generation when a processor probe detects that the processor is absent Sets action or enables or disables alert generation when the system fans and or power supplies become inoperative resulting in less than full redundancy for that component 109 Event Name event redunlost event systempowerwarn event systempowerfail event tempwarn event removableflashmediapre sent event removableflashmediawa rn event removableflashmediafail event tempfail event voltfail event intdualsdcardcritical event intdualsdcardwarn event intdualsdcardabsent event intdualsdcardredunlost event watchdogasr Description Sets action or enables or disables alert generation when the system fans and or power supplies become inoperative resulting in a lost or a no redundant components working condition for that component Sets actions when a power consumption probe detects a warning value Sets actions when a power consumption probe detects a failure value Sets action or enables or disables alert generation when a temperature probe detects that the temperature is approaching the maximum high or low limits Sets actions that Server Administrator performs when the system detects a removable flash media Sets actions that Server Administrator performs when a removable flash media warning is displayed Sets actions that Server Administrator per
226. ted data in custom delimited format You can specify this option with any omreport command For example to generate a system summary in custom delimited format type omreport system summary fmt cdv or omreport servermodule summary fmt cdv You can also set preferences for the custom delimited format with the omconfig command The valid values for delimiters are exclamation semicolon at hash dollar percent caret asterisk tilde question colon comma and pipe The following example shows how to set the delimiter for separating data fields to asterisk omconfig preferences cdvformat delimiter asterisk 198
227. teger gt ng lt string gt ng lt string gt ng lt string gt ng lt string gt ng lt integer gt ng lt string gt ng lt string gt ng lt string gt ng lt string gt ng lt integer gt ng lt string gt ng lt string gt ng lt string gt ng lt string gt ng lt integer gt ng lt string gt Di Di Di Di sabled sabled sabled sabled ng Enabled Disabled ng lt string gt ng Single All Dual Quad 1 2141618 12 14 16 ng lt string gt ng Enabled Disabled ing Enabled Disabled 79 Group 80 name value pair 1 attribute attribute ProcVirtualization attribute QpiBandwidthPriority attribute QpiSpeed attribute RtidSetting attribute EmbSata attribute eSataPort1 attribute eSataPortiCapacity attribute eSataPort1DriveType attribute eSataPortiModel attribute SataPortA attribute SataPortACapacity attribute SataPortADriveType attribute SataPortAModel attribute SataPortB attribute SataPortBCapacity attribute SataPortBDriveType attribute SataPortBModel attribute SataPortC attribute SataPortCCapacity attribute SataPortCDriveType attribute SataPortCModel attribute SataPortD attribute SataPortDCapacity attribute SataPortDDriveType attribute SataPortDModel attribute SataPortE attribute SataPortECapacity attribute SataPortEDriveType attribute SataPortEModel attribute SataPortF attribute SataPortFCapacity attribute SataPortFDriveType attribute SataPortFModel name value
228. the baseboard serial controller into the BMC enableipmi true false true Enables IPMI over LAN false Disables IPMI over LAN enablenic true false true Enables DRAC NIC false Disables DRAC NIC 91 name value pair 1 config 92 name value pair 2 nicselection sharedwithfailover onall nic1 teamednicinic2 dracnic primarynw dedicated lom1 lom2 lom3 lom4 failovernw none lom1 lom2 lom3 lom4 all Description K NOTE The enablenic option is supported on PowerEdge 9G systems that have DRAC 5 installed sharedwithfailoveronall Configures the new NIC selection option nic1 Enables NIC 1 teamednicinic2 Enables NIC teaming functionality dracnic Enables DRAC NIC if DRAC 5 is installed K NOTE The nicselection option is supported only on PowerEdge 9G to 11G systems From PowerEdge 12G systems onwards primarynw and failovernw replaces nicselection dedicated Configures dedicated port as primary network for remote access K NOTE This option requires license to configure primarynw as dedicated If the appropriate license is not installed or has expired the system displays an error message For more information see Dell License Manager at dell com openmanagemanuals lom 1 Configures lom1 port as the primary network for remote access lom 2 Configures lom2 port as the primary network for remote access lom 3 Configures lom3 port as the primary network for r
229. the command Table 35 Valid Parameters Of Omconfig Preferences Dirservice name value pair Description prodname lt text gt Specifies the product to which you want to apply the Active Directory configuration changes prodname refers to the name of the product defined in omprv32 ini For Server Administrator it is omsa enable lt true true Enables Active Directory service authentication support and the Active false gt Directory Login option on the login page false Disables Active Directory service authentication support and the Active Directory Login option on the login page If the Active Directory Login option is not present you can only login to the local machine accounts adprodname lt tex Specifies the name of the product as defined in the Active Directory service This t gt name links the product with the Active Directory privilege data for user authentication 101 Omconfig Preferences Messages Use the omconfig preferences messages command to select the format of alert messages The default format is traditional which is the legacy format The following table lists the parameters you can use with this command Table 36 Valid Parameters Of Configuring Preferences Messages name value pair 1 namecvalue pair 2 Description attribute format setting traditional traditional Sets the alert message to traditional enhanced format enhanced Sets the alert message to Enhanced Event Messaging format This is similar to
230. the format available in iDRAC7 For example to set the message format to traditional use the following command omconfig preferences messages format traditional Omconfig Preferences Useraccess Depending on the policies of your organization you may want to restrict the access that some user levels have to Server Administrator The omconfig preferences useraccess command allows you to grant or withhold the right of users and power users to access Server Administrator The following table displays the valid parameters for the command Table 37 Enabling User Access For Administrators Power Users And Users Command Result Description omconfig preferences Grants Server Administrator Least restrictive form of user useraccess enable user access to Users Power Users access and Administrators omconfig preferences Grants Server Administrator Excludes user level access only useraccess enable poweruser access to Power Users and Administrators omconfig preferences Grants Server Administrator Most restrictive form of user useraccess enable admin access to Administrators only access Omconfig Preferences Webserver Use the omconfig preferences webserver command to set the encryption levels of the Server Administrator Web server configure the URL launch point in the Server Administrator Web server environment and to set the JRE version for the Server Administrator The following table displays the name value pairs you can use with
231. the valid severity parameters 111 Table 45 System Event Severity Parameters Command Result Description omconfig system events Enables notification for Least restrictive form of event type component name informational warning and notification severity info or omconfig critical events servermodule events type component name gt severity info omconfig system events Enables notification for warning Omits informational event type component name gt and critical events notification for example when a severity warning or omconfig component returns to normal servermodule events status type lt component name gt severity warning omconfig system events Enables notification for critical Restrictive form of event type lt component name gt events only notification severity critical or omconfig servermodule events type lt component name gt severity critical omconfig system events Disables event notification No event notification type lt component name gt severity none or omconfig servermodule events type lt component name gt severity none Index Index refers to the number of an event for a particular component Index is an optional parameter When you omit the index parameter events are configured for all components of the specified type such as all fans For example when a system contains more than one fan you can enable or disable event notification for a particular fan An example command is
232. this command Table 38 Valid Parameters Of Omconfig Preferences Webserver name value pair 1 name value pair 2 Description attribute sslencryption setting autonegotiate autonegotiate Sets the 128bitorhigher encryption levels automatically based on your Web browser settings 102 name value pair 1 name value pair 2 Description 128bitorhigher Sets the encryption levels to 128 bit or higher attribute seturl host lt string gt port lt value gt Enables you to configure the URL launch point in the Server Administrator Web server environment attribute signalgorithm algorithm MD5 SHA1 SHA256 MD5 Sets the key signing SHA512 algorithm to MD5 SHA1 Sets the key signing algorithm to SHA1 SHA256 Sets the key signing algorithm to SHA256 SHA512 Sets the key signing algorithm to SHA512 attribute setjre jreversion bundled value bundled Sets the OMSA bundled version as default value Sets the version which user inputs and available on the system For example to set the URL launch point use the following command omconfig preferences webserver attribute seturl host lt name gt ip fqdn gt port lt number gt The host input must contain a valid IPv4 or IPv6 address or a valid hostname To set the signing algorithm value use the following command omconfig preferences webserver attribute signalgorithm algorithm MD5 To set the JRE versions use the following command omconfig preferences
233. tings On PowerEdge 12G systems The following table lists the BIOS setup attributes supported on PowerEdge 12G systems On PowerEdge 12G systems the attributes are grouped Based on the hardware configuration the possible attributes may vary in a specific group The omconfig chassis biossetup command does not display the read only attributes NOTE If you have configured the setup password then always set the same when you configure any BIOS settings Table 22 BIOS Setup Settings On PowerEdge 12G Systems Group name value pair 1 attribute name value pair 2 setting BIOS Boot attribute BootSeq sequence aliasname1 aliasname2 aliasnameN Settings attribute HddSeq sequence aliasnamel aliasname2 aliasnameN Boot Settings attribute BootMode setting Bios Uefi attribute BootSeqRetry setting Enabled Disabled Embedded Server attribute FrontLcd setting None UserDefined ModelNum Management Advanced attribute UserLcdStr setting lt string gt Integrated attribute EmbVideo setting Enabled Disabled Devices attribute IntegratedNetwork1 setting Enabled DisabledOs attribute IntegratedNetwork2 setting Enabled DisabledOs attribute IntegratedRaid setting Enabled Disabled attribute IntegratedSas setting Enabled Disabled attribute InternalSdCard setting On Off attribute InternalSdCardRedun setting Mirror Disabled dancy attribute InternalUsb setting On Off 77 Group Memory Settings Miscella
234. to detect RAID on motherboard as a RAID device off Disables RAID on motherboard during system boot e scsi Instructs the BIOS to detect the RAID on motherboard device as a SCSI device e force true Verification of setting change raid Instructs the BIOS to detect RAID on motherboard channel A as a RAID device e scsi Instructs the BIOS to detect the RAID on motherboard device as a SCSI device e force true Verification of setting change raid Instructs the BIOS to detect RAID on motherboard channel B as a RAID device e scsi Instructs the BIOS to detect the RAID on motherboard device as a SCSI device e force true Verification of setting change e off Disables the SATA controller ata Sets the onboard SATA controller to ATA mode raid Sets the onboard SATA controller to RAID mode e off Disables the SATA port name value pair 1 attribute attribute secondaryscsi attribute serialportaddr attribute serialcom attribute serialportl name value pair 2 setting setting on off setting default alternate com1 com2 setting off on com1 com onwithconsole setting off auto com1 coms bmcserial bmcnic rac comibmc Description auto Automatically enables the SATA port e on Enables secondary SCSI off Disables this device default Maps to Serial device12 COMI Serial device2 COM2 alternate Maps to Serial device
235. to display the controller IDs and then type omreport storage cachecade controller ID to display the IDs for the cachecades of the controller Blinks the physical disk in cachecade 4 on controller 1 omconfig storage cachecade action blink controller 1 cachecade 4 Omconfig Unblink Cachecade Description Syntax Unblinks the physical disks included in a cachecade omconfig storage cachecade action unblink controller id cachecade id where id is the controller ID and the cachecade ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller ID to display the IDs for the cachecades of the controller 187 Example to Example Unblinks the physical disk in cachecade 4 on controller 1 omconfig storage cachecade action unblink controller 1 cachecade 4 Omconfig Delete Cachecade Description Syntax Example to Example Deletes a cachecade omconfig storage cachecade action deletecachecad controller id cachecade id where idis the controller ID and the cachecade ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller ID to display the IDs for the cachecades of the controller In some circumstances you may receive a warning message You can override this warning by using the force
236. troller 1 enclosure 2 3 Table 113 omconfig Blink Description Syntax Example to Example for SAS controllers Example for SCSI SATA and ATA controllers UJ inks the light emitting diodes LEDs on the enclosure omconfig storage enclosure action blink controller id enclosure lt ENCLOSUREID gt where id is the controller ID The lt ENCLOSUREID gt variable specifies the enclosure B ink the LEDs for enclosure 3 attached to connector 2 on controller 1 omconfig storage enclosure action blink controller 1 enclosure 2 3 omconfig storage enclosure action blink controller 1 enclosure 2 183 Omconfig Battery Commands The following table displays the omconfig command syntax required to execute battery tasks Table 114 Omconfig Battery Commands Required Command Optional name value pairs Levels 1 2 3 omconfig storage action startlearn controller id battery id battery action delaylearn controller id battery id days d hours h omconfig Start Battery Learn Cycle Table 115 Omconfig Start Battery Learn Cycle Description Starts the battery learn cycle Syntax omconfig storage battery action startlearn controller id battery id where id is the controller ID and battery ID as reported by the omreport command To obtain this value type omreport storage controller to display the controller IDs and then type omreport storage battery controller ID to display the ID for the controller battery Exam
237. ttribute Slots attribute Slot4 attribute Slot5 attribute Slot6 attribute Slot7 attribute SysMfrContactInfo attribute SystemBiosVersion attribute SystemManufacturer attribute SystemModelName attribute SystemServiceTag attribute MemFrequency attribute MemPatrolScrub attribute MemRefreshRate name value pair 2 setting setti setti setti setti sett setti setti setti sett setti setti setti setti ng Off Auto ng lt string gt ng lt string gt ng lt string gt ing Off Auto ng lt string gt ng lt string gt ng lt string gt ing Vt100Vt220 Ansi ng Serial1 Serial2 RemoteAccDevice ng 115200 57600 19200 9600 ng Enabled Disabled ng OnNoConRedir OnConRedirComl OnConRedirCom2 Off setti ng SeriallCom1Serial2Com SeriallCom2Serial2Com1 Com1 Com2 setti setti setti sett setti setti setti setti setti setti setti setti sett 80 setti setti ng Enabled Disabled BootDriverDisabled ng Enabled Disabled BootDriverDisabled ng Enabled Disabled BootDriverDisabled ing Enabled Disabled BootDriverDisabled ng Enabled Disabled BootDriverDisabled ng Enabled Disabled BootDriverDisabled ng Enabled Disabled BootDriverDisabled ng lt string gt ng lt string gt ng lt string gt ng lt string gt ng lt string gt ing MaxPerf 1600MHz 1333MHz 1067MHz OMHz MaxRelia
238. tual disk omconfig storage vdisk action cancelbginitialize controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command K NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controllerzID to display the IDs for the virtual disks attached to the controller Cancel background initialization on virtual disk 4 on controller 1 omconfig storage vdisk action cancelbginitialize controller 1 vdisk 4 Omconfig Assign Dedicated Hot Spare Description Syntax Example to Example for SCSI SATA and ATA controllers Example for SAS controllers Assigns one or more physical disks to a virtual disk as a dedicated hot spare omconfig storage vdisk action assigndedicatedhotspare controller id vdisk id pdisk PDISKID assign yes where id is the controller ID and virtual disk ID as reported by the omreport command The PDISK variable specifies the physical disk A NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks and physical disks attached to the controller Assign physical disk 3 on connector 0 of controller 1 as a dedicated hot spare to virtual disk 4 On a Serial Attached SCSI SAS controller the physical disk resides in enclosure 2 omconfig storage vdisk action ass
239. u can configure the system for a thermal shutdown when a temperature probe detects a temperature probe warning or failure event The following table displays the valid parameters for the command Table 49 Valid Parameters Of Thermal Shutdown name value pair Description severity disabled warning disabled Disable thermal shutdown An administrator must intervene failure 114 warning Perform a shutdown when a temperature warning event is detected A warning event occurs when any temperature probe inside a chassis reads a temperature in degree Celsius that exceeds the maximum temperature warning threshold value failure Perform a shutdown when a temperature failure event is detected A failure event occurs when any temperature probe inside name val ue pair Description a chassis reads a temperature in degree Celsius that exceeds the maximum temperature failure threshold value Example Thermal Shutdown Commands To trigger a thermal shutdown when a temperature probe detects a failure event type omconfig or omconfig To disable omconfig or omconfig system thrmshutdown severity failur servermodule thrmshutdown severity failur thermal shutdown so that an administrator has to initiate an omconfig system shutdown type system thrmshutdown severity disabled servermodule thrmshutdown severity disabled 115 116 Omconfig System Or Servermodule Assetinfo Editing Cost Of Ownersh
240. u have selected static as the IP address source for the BMC LAN interface Sets a gateway address if you have selected static as the IP address source for the BMC LAN interface static Static if the IP address of the BMC LAN interface is a fixed assigned IP address dhcp DHCP if the source of the IP address of the BMC LAN interface is the dynamic host configuration protocol systemsoftware System software if the source of the IP address of the BMC LAN interface is from the system software K NOTE All commands may not be supported on the system Validates the IPv6 address for configuration Validates the IPv6 gateway static IPv6 address source is set to static auto IPv6 address source is set to auto Validates the address of the alternate DNS server for configuration Static DNS source is set to static auto DNS source is set to auto true Enables the virtual LAN identification false Disables the virtual LAN identification number Virtual LAN identification in the range of 1to 4094 93 name value pair 1 config config serial 94 name value pair 2 vlanpriority number privilegelevel administrator operator user encryptkey text confirmencryptkey text prefdnsserverv6 lt value gt baudrate 9600 19200 38400 57600 115200 flowcontrol none rtscts mode directbasic directterminal directbasicterminal Description number Priority of virtual LAN identificatio
241. ues type omreport storage controller to display the controller IDs and then type omreport storage vdisk controllerzID to display the IDs for the virtual disks attached to the controller Reconfigure virtual disk 4 to a size of 800 MB use RAID 5 and physical disks O through 3 on connector 0 of controller 1 On a SAS controller the physical disks reside in enclosure 2 omconfig storage vdisk action reconfigure controller 1 vdisk 4 raid r5 size 800m pdisk 0 0 0 1 0 2 0 3 omconfig storage vdisk action reconfigure controller 1 vdisk 4 raid r5 pdisk 0 2 0 0 2 1 0 2 2 0 2 3 Increase the size of the virtual disk by 20 percent using the available free space use RAID 5 and physical disks O through 3 on connector 0 of controller 1 On a SAS controller the physical disks reside in enclosure 2 omconfig storage vdisk action reconfigure controller 1 vdisk 4 raid r5 pdisk 0 2 0 0 2 1 0 2 2 0 2 3 vdcapacityexpansion yes sizeinpercent 20 K NOTE vdcapacityexpansion parameter is supported only on PERC H700 and PERC H800 controllers If you set vdcapacityexpansion yes specify sizeinpercent If you do not set vdcapacityexpansion specify size Omconfig Secure Virtual Disk Description Syntax Example to Example Encrypts a virtual disk omconfig storage vdisk action securevd controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command NOTE To obtain these values type omrepo
242. ummary of software and hardware components currently installed on the system Type omreport system summary or omreport servermodule summary E NOTE If the vFlash or SD card size is less than 1 GB the size is displayed in MB K NOTE If iDRAC is installed Server Administrator displays the LCC version If BMC is installed Server Administrator displays the USC version The output that is displayed in the CLI window depends on the systems management software operating system and hardware components and options installed on the system The following partial command results are unique and may not resemble the hardware and software configuration of the system System Summary Systems Management Name Dell OpenManage Systems Management Software 64 Bit Version T X X X Description Systems Management Software Contains Apache Tomcat Webserver x x x Common Storage Module x x x 52 Operating System Name Version System Time System Bootup Time Server Module Information Host Name System Location Model Asset Tag Service Tag Data Engine x x x Hardware Application Programming Interface x x x Instrumentation Servicex x x Instrumentation Service Integration Layer x x x Intel SNMP Agent x x x Inventory Collector x x x OMACS X X X Operating System Loggingx x x Oracle Java Runtime Environment x x x Remote Access Controller Managed Node x x x Server Administrator Common Fra
243. upport PMBus and that have hot swappable power supplies and not systems that have a fixed non redundant power supply installed E NOTE Power monitoring requires license to report the details If the appropriate license is not installed or has expired the system does not display the power consumption details of the system For more information see the Dell License Manager Guide at dell com openmanagemanuals E NOTE To maintain consistency across the commands the output format of this command and the subsequent command levels has changed So you may have to change the user scripts as applicable An example output reporting power statistics in Watts is as follows Power Consumption Information Power Consumption Index Status Probe Name Reading Warning Threshold Failure Threshold Amperage PS1 Current 1 Power Headroom System Instantaneous Headroom System Peak Headroom Power Tracking Statistics Statistic Measurement Start Time Measurement Finish Time Reading Statistics easurement Start Time Peak Time Peak Reading Statistics easured Since Read Time 1 Ok System Board Pwr Consumption 539W 994W 1400 W 300 W 340 W Energy consumption Thu May 28 11 03 20 2011 Fri May 28 11 05 46 2011 5 9 KWH System Peak Power Mon May 18 16 03 20 2011 Wed May 27 00 23 46 2011 630 W System Peak Amperag Mon May 18 16 03 20 2011 Tue May 19 04 06 32 2011 41 Peak Reading x
244. ures power consumption information g and thresholds remoteaccess A Configures remote access information temps DA Sets warning threshold values to the default or a specific value K NOTE You cannot change threshold values on ESM3 and PowerEdge x8xx systems volts P A Sets warning threshold values to the default or a specific value K NOTE You cannot change threshold values on ESM3 and PowerEdge x8xx systems For more information see Using The Storage Management Service Help With The Omconfig Command The following table lists the usage of omconfig commands Table 20 Usage Of Omconfig Commands Command Usage omconfig omconfig lt command level 2 gt omconfig chassis omconfig system omconfig preferences 7 omconfig preferences cdvformat omconfig system command level 3 omconfig system alertaction 64 Description To display the list of the available commands for omconfig To display the help for about chassis preferences and system s level 2 commands To display the help for omconfig chassis command To display the help for omconfig system command To display the available commands for omconfig preferences such as cdvformat which is the custom delimiter format cdv To display the list of delimiter values for the cdv To display the list of the parameters you must use to execute a particular omconfig system command To display the list of valid parameter
245. w NIC properties type omreport chassis nics index n or omreport chassis nics index n The index parameter is optional If you do not specify the index Server Administrator displays properties of all NICs on the system and the values for the following fields Index NIC card number Interface Name Vendor Description Connection Status and Slot If you specify the index Server Administrator displays properties for a specific NIC and the values for the following fields Physical Interface Interface name IPv4 Addresses IPv6 Addresses Physical Interface Receive Statistics Physical Interface Transmit Statistics Interface Receive Statistics and Interface Transmit Statistics NOTE The Fibre Channel over Ethernet FCoE and iSCSI over Ethernet iSoE features of Converged Network Adapter CNA cards are not supported on VMware ESX and VMware ESXi systems To view Team interface properties type omreport chassis nics config team index n 35 or omreport mainsystem nics config team index n NOTE This command is applicable only if Team interface is configured in the system Team interface is configured using NIC vendor tools such as Broadcom The index parameter is optional If you do not specify the index Server Administrator displays details of all the Team interfaces on the system and the values for the following fields Index NIC card number Interface Name Vendor Description and Redundancy Status If you specify th
246. webserver attribute setjre jreversion bundled value Omconfig System Or Omconfig Servermodule Use the omconfig system or omconfig servermodule commands to clear logs determine how various shutdown actions occur set initial values or edit values for cost of ownership information and determine how to respond to a hung operating system Omconfig System Alertaction Or Omconfig Servermodule Alertaction You can use the omconfig system alertaction or omconfig servermodule alertaction command to determine how Server Administrator responds when a component has a warning or failure event NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator Defining Alert Actions An alert action is an action that you specify for the system to take when specified conditions are met Alert actions determine in advance what actions to take for warning or failure events on intrusion fans temperatures voltages power supplies memory and redundancy 103 For example if a fan probe on the system reads a fan RPM of 500 and your minimum warning threshold value for that fan probe is 600 RPM then the system generates a fan probe warning Alert action settings determine how users are notified of this event You can also configure alert actions for temperature voltage and probe readings that fall within the warning or failure range Syntax Fo
247. yes parameter In this case the syntax is as follows omconfig storage cachecade action deletecachecad controller id cachecade id force yes Delete cachecade 4 on controller 1 omconfig storage cachecade action deletecachecad controller 1 cachecade 4 Omconfig Resize Cachecade Description Syntax Example to Example for SAS controllers Example for SCSI SATA and ATA controllers Resizes a cachecade by adding or removing physical disks omconfig storage cachecade action resize controller id cachecade id pdisk lt PDISKID gt where id is the controller ID and the cachecade ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller ID to display the IDs for the cachecades of the controller Resize cachecade 4 use physical disks O through 5 on connector 0 of controller 1 omconfig storage cachecade action resize controller 1 cachecade 4 pdisk 0 2 0 0 2 1 0 2 2 0 2 3 omconfig storage cachecade action resize controller 1 cachecade 4 pdisk 0 0 0 1 0 2 0 3 Omconfig Rename Cachecade Description Syntax Example to 188 Renames a cachecade omconfig storage cachecade action rename controller id cachecade id name lt string gt where id is the controller ID and the cachecade ID as reported by the omreport command To obtain these values type omreport storage controller to display th
248. ying enclosure information battery Displays a list of the omreport storage battery parameters for displaying battery information globalinfo Displays a list of the omreport storage globalinfo parameters for displaying global storage property information connector Displays a list of the omreport storage connector parameters for displaying connector information cachecade Displays a list of the omreport storage cachecade parameters for displaying cachecade properties pciessed Displays the properties of the PCle SSD subsystem fluidcache Displays the fluid cache properties and the associated fluid cache disks 155 Command Level 2 Command Level 1 Command Level 3 Use fluidcachepool Displays fluid cache pool properties partition disk Displays the partition details of the specified virtual fluidcachedisk Displays the fluid cache disk properties Omreport Physical Disk Status The following table describes the syntax for the omreport Physical Disk commands Table 65 Omreport Physical Disk Commands Required Command Levels 1 2 3 And name value pair omreport storage pdisk Optional name value pairs controller id where id is the controller number For example controller 0 vdisk id where id is the virtual disk number For example vdisk 1 cachecade id where id is the cachecade number For example cachecade 1 connector id where id is the connector number For example connector
249. yntax Example to Example for SAS controllers Omconfig Disable Device Write Cache Description Syntax Example to NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controllerzID to display the IDs for the physical disks attached to the controller Es Cancel the clear of physical disk 5 on connector 0 of controller 1 On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action cancelclear controller 1 pdisk 0 2 3 Enables write cache on a physical disk for the PCle SSD controller omconfig storage pdisk action enabledevicewritecach controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk Es NOTE To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Enable write cache on physical disk 5 on connector O of controller 1 On a SAS controller the physical disk resides in enclosure 2 omconfig storage pdisk action enabledevicewritecach controller 1 pdisk 0 2 3 Disables write cache on a physical disk for the PCle SSD controller omconfig storage pdisk action disabledevicewritecach controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variab
250. ystem Frontpanel Use the omconfig chassis frontpanel or omconfig mainsystem frontpanel command to e configure the power button and the Nonmasking Interrupt NMI button e configure the LCD to display No information Custom information Default system information Service tag system name Remote access MAC addresses System power Remote access IP address Ambient temperature of the system Remote access IPv4 address Remote access IPv6 address Specify and configure the LCD line number e View the encryption state report of the LCD e Configure LCD to indicate an active remote session when the Kernel based Virtual Machine KVM is available E NOTE You can configure the Power and NMI buttons only if they are present on the system The following table displays the valid parameters for the command Table 24 Valid Parameters Of Omconfig Chassis Frontpanel Or Omconfig Mainsystem Frontpanel name value pair 1 name value Description pair 2 Icdindex index NA Specifies the LCD line number config none default NA none Sets the LCD text to none custom e default Sets the LCD text to default e custom Sets the LCD text to custom text lt custom text gt NA Sets the custom text for LCD when config custom ER PS e enable Enables the NMI button on the system isable e disable Disables the NMI button on the system 84 name value pair 1 powerbutton enable disable c
Download Pdf Manuals