1. deviceTypelIsOther 1 Device type is not one of the following deviceTypelIsUnknown 2 Device type is unknown deviceTypeIsDRAM 3 Device type is DRAM deviceTypelIsEDRAM 4 Device type is EDRAM deviceTypeIsVRAM 5 Device type is VRAM deviceTypelIsSRAM 6 Device type is SRAM deviceTypeIsRAM 7 Device type is RAM deviceTypeIsROM 8 Device type is ROM deviceTypeIsFLASH 9 Device type is FLASH deviceTypeIsEEPROM 10 Device type is EEPROM deviceTypelIsFEPROM 11 Device type is FEPROM deviceTypeIsEPROM 12 Device type is EPROM deviceTypeIsCDRAM 13 Device type is CDRAM deviceTypelIs3DRAM 14 Device type is 3DRAM 336 Device Group Table 13 16 Memory Device Type continued Variable Name De 1 1MemoryDeviceTyp Data Type Integer Possible Data Values Meaning of Data Value deviceTypeIsSDRAM 15 Device type is SDRAM deviceTypeIsSGRAM 16 Device type is SGRAM deviceTypeIsRDRAM 17 Device type is RDRAM deviceTypeIsDDR 18 Device type is DDR deviceTypelIsDDR2 19 Device type is DDR2 deviceTypeIsDDR2FBDIMM 20 Device type is DDR2 FB DIMM deviceTypelIsDDR3 24 Device type is DDR3 deviceTypelIsFBD2 25 Device type is FBD2 Table 13 17 Memory Device Type Details Variable Name Del 1MemoryDeviceTypeDetails Data Type Integer Possible Data Values Meaning of
2. 704 Voltage Probe Traps 706 Amperage Probe Traps 708 Chassis Intrusion Traps 710 Redundancy Unit Traps 711 Power Supply Traps 713 Memory Device Traps 715 Fan Enclosure Traps 716 AC Power Cord Traps 717 Hardware LogTraps 718 Processor Device Status Traps 719 Contents 15 Pluggable Device Traps 721 Battery Traps 2 ee ee eee 722 SD Card Device Traps 724 RAG Traps 86 ria a ves Ad Oe e BA we ba ed 725 BMC Traps i epi tec ee os aa E EA hw bes 731 27 Storage Management Alert Reference 737 Alert Monitoring andLogging 737 Viewing Alerts 0 2 4 738 Alert Severity Levels 738 SNMP Support for Storage Management Alerts 739 SNMP Trap Forwarding 739 SNMP Trap Definitions 740 SNMP Trap Variables 740 ViewingSNMPTraps 741 Alert Descriptions and Corrective Actions 741 A Standard Data Type Definitions 743 Common DataTypes 743 Variables with Data Types of State Capabilities and State Capabilities Unique 744 Dell Status DataTypes 746 Dell Date 30 2 ge e we nt ea sca Re 741 Full Dates 3 2 3 Sede ea SP PRES a 748 16 Contents Contents 17
3. physicalMemoryArrayECCErrorNonRecoverbeThreshold 1 3 6 1 4 1 674 10892 1 1300 10 1 12 Defines the value of the physical memory array Error Checking and Correction ECC error nonrecoverable threshold DellSigned32BitRange Read only Physical Memory Array ECC Error Critical Threshold Name Object ID Description Syntax Access physicalMemoryArrayECCErrorCriticalThreshold 1 3 6 1 4 1 674 10892 1 1300 10 1 13 Defines the value of the physical memory array ECC error critical threshold DellSigned32BitRange Read only Physical Memory Array ECC Error Noncritical Threshold Name Object ID Description Syntax Access physicalMemoryArrayECCErrorNonCriticalThreshold 1 3 6 1 4 1 674 10892 1 1300 10 1 14 Defines the value of the physical memory array ECC error noncritical threshold DellSigned32BitRange read write Memory Group 363 Physical Memory Array Redundant Memory Unit Index Reference Object ID Description Syntax Access physicalMemoryArrayRedundantMemoryUnitIndex Reference 1 3 6 1 4 1 674 10892 1 1300 10 1 15 Defines the index to the associated Redundant Memory Unit in this chassis DellObjectRange Read only Physical Memory Array Mapped Table The physical memory array is divided into memory array mapped addresses The following object sets up the Physical Memory Array Mapped Table Name Object ID Description Syntax Access phy
4. 317 Table 13 1 Pointing Device Type continued Variable Name De 1 1PointingDeviceType Data Type Integer Possible Data Values Meaning of Data Value deviceTypelsATrackBall 4 Device type is a track ball deviceTypelsATrackPoint 5 Device type is a track point deviceTypeIsAGlidePoint 6 Device type isa glide point deviceTypeIsATouchPad 7 Device type is a touch pad Table 13 2 Processor Device Status State Variable Name De 1 1ProcessorDeviceStatusState Data Type Integer Possible Data Values Meaning of Data Value other 1 Processor device type is not one of the following unknown 2 Device type is unknown enabled 3 Device is enabled userDisabled 4 Device is disabled by the user biosDisabled 5 Device has its BIOS disabled idle 6 Device is idle Table 13 3 Processor Device Status Reading Variable Name De 1 1ProcessorDeviceStatusReading Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value internalError 1 The processor experienced an internal error thermalTrip 2 The processor experienced a thermal trip 318 Device Group Table 13 3 Processor Device Status Reading continued Variable Name De 1 1ProcessorDeviceStatusReading Data Type Integer NOTE These values are bit masks so combination values are possib
5. deviceFamilyIsIntelCore2SoloMo The processor family is Intel Core2 Solo bile 197 mobile processor deviceFamilyIsIntelCorei7 198 The processor family is Intel Core i7 processor 328 Device Group Table 13 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreIntelCel The processor family is Dual Core Intel eron 199 Celeron Processor deviceFamilyIsIBM390 200 The processor family is IBM390 deviceFamilyIsG4 201 The processor family is G4 deviceFamilyIsG5 202 The processor family is G5 deviceFamilyIsESA390G6 203 The processor family is ESA 390 G6 deviceFamilyIszArchitectur 204 The processor family is z Architectur base deviceFamilyIsIntelCorei5 205 The processor family is Intel R Core TM i5 processor deviceFamilyIsVIAC7 M 210 The processor family is VIA C7 TM M deviceFamilyIsVIAC7 D 211 The processor family is family is VIA C7 TM D deviceFamilyIsVIAC7 212 The processor family is VIA C7 TM deviceFamilyIsVIAEden 213 The processor family VIA Eden TM deviceFamilyIsMultiCoreIntelxe The processor family is Multi Core Intel on 214 Xeon processor deviceFamilyIsDualCoreIntelxeo The processor family is Dual Core Intel n3xxx 215 Xeon processor 3xxx Series deviceFamilyIsQuadCoreIntel
6. systemResourceMemoryOwnerIndexReferenc 1 3 6 1 4 1 674 10892 1 500 40 1 6 Defines the index to the associated system resource owner in this chassis DellObjectRange Read only System Resource Memory Share Disposition Name Object ID Description Syntax Access systemResourceMemoryShareDisposition 1 3 6 1 4 1 674 10892 1 500 40 1 7 Defines the share disposition of the system resource memory DellResourceShareDisposition See Table 7 3 Read only System Resource Memory Starting Address Name Object ID Description Syntax Access systemResourceMemoryStartingAddress 1 3 6 1 4 1 674 10892 1 500 40 1 8 Defines the 64 bits of the starting address of the system resource memory DellUnsigned64BitRange Read only System Resource Memory Ending Address Name Object ID Description Syntax Access systemResourceMemoryEndingAddress 1 3 6 1 4 1 674 10892 1 500 40 1 9 Defines the 64 bits of the ending address of the system resource memory DellUnsigned64BitRange Read only System Resource Group 137 System Resource Memory Flags Name systemResourceMemoryFlags Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 10 Description Defines the permission flags for the system resource memory Syntax DellResourceMemoryF lags See Table 7 4 Access Read only System Resource Interrupt Table Name systemResourceInterruptTable Object ID 1 3 6 1 4 1 674 10892 1 500 50 Description Defines the System
7. Introduction 37 Other Documents You May Need In addition to this Server Administrator SNMP Reference Guide you can find the following guides on the Dell Support website at support dell com manuals To access these documents go to support dell com manuals and select your product or use the direct link on the Dell Systems Management Tools and Documentation DVD e The Server Administrator Messages Reference Guide lists the messages that you can receive on your systems management console or on your operating system s event viewer This guide explains the text severity and cause of each message that the server administrator issues e The Server Administrator CIM Reference Guide documents the Common Information Model CIM provider an extension of the standard management object format MOF file The Server Administrator provider documents supported classes of management objects e The Glossary provides information on the terms used in this document Introduction to the Server Administrator SNMP Subagent This guide provides formatted information drawn primarily from the MIB files written for the Server Administrator services that support the SNMP protocol For each of the variables defined in the MIBs the following fields are specified Variable name e OID or unique identifying number e Description e Data type of the variable for example integer string octet string e Whether the variable is accessible not accessible
8. processorDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 30 1 4 Defines the state of the processor device DellStateSettings Read write Processor Device Status Name Object ID Description Syntax Access processorDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 30 1 5 Defines the status of the processor device DellStatus Read only Processor Port Index Reference Name Object ID Description Syntax Access 266 processorPortIndexReference 1 3 6 1 4 1 674 10892 1 1100 30 1 6 Defines the index to the associated processor port in this chassis DellObjectRange Read only Device Group Processor Device Type Name Object ID Description Syntax Access processorDeviceTyp 1 3 6 1 4 1 674 10892 1 1100 30 1 7 Defines the type of processor device DellProcessorDeviceType See Table 13 4 Read only Processor Device Manufacturer Name Name Object ID Description Syntax Access processorDeviceManufacturerName 1 3 6 1 4 1 674 10892 1 1100 30 1 8 Defines the name of manufacturer of the processor device DellString Read only Processor Device Status State Name Object ID Description Syntax Access processorDeviceStatusState 1 3 6 1 4 1 674 10892 1 1100 30 1 9 Defines the status state of the processor device DellProcessorDeviceStatusState See Table 13 2 Read only Processor Device Family Name Object ID Description Syntax Access processorDeviceFamily 1 3 6 1 4 1
9. Access Fan Entry Name Object ID Description Syntax Access Index Fan Number Name Object ID Description Syntax Access fanTable 1 3 6 1 4 1 674 10893 1 20 130 7 Defines the fan table SEQUENCE OF FanEntry Not accessible fanEntry 1 3 6 1 4 1 674 10893 1 20 130 7 1 Defines the fan table entry FanEntry Not accessible fanNumber fanNumber 1 3 6 1 4 1 674 10893 1 20 130 7 1 1 Identifies the instance number of the fan entry Integer Read only Storage Management Group 603 Fan Name Name Object ID Description Syntax Access Fan Vendor Name Object ID Description Syntax Access Fan State Name Object ID Description Syntax Access Fan Name 1 3 6 1 4 1 674 10893 1 20 130 7 1 2 Identifies the fan s name as represented in Storage Management DisplayString Read only fanVendor 1 3 6 1 4 1 674 10893 1 20 130 7 1 3 Identifies the fan s re seller s name DisplayString Read only fanState 1 3 6 1 4 1 674 10893 1 20 130 7 1 4 Identifies the current state of the fan Possible states 0 Unknown 1 Ready 2 Failed 3 Online 4 Offline 6 Degraded 21 Missing Integer Read only 604 Storage Management Group Fan Severity Name fanSeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 5 Description This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Syntax Integer Access Read only F
10. BMC LAN Interface Chassis Index Name bmcLANInterfaceChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 1 Description Defines the index one based of the associated chassis Syntax DellObjectRange Access Read only Baseboard Management Controller Group 529 BMC LAN Interface BMC Index Name bmcLANInterfaceBMC Index Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 2 Description Defines the index one based of the associated BMC Syntax DellObjectRange Access Read only BMC LAN Interface Index Name bmcLANInterfaceIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 3 Description Defines the index one based of the BMC LAN interface Syntax DellObjectRange Access Read only BMC LAN Interface State Capabilities Name bmcLANInterfaceStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 4 Description Defines the state capabilities of the BMC LAN interface Syntax DellStateCapabilities Access Read only BMC LAN Interface State Settings Name bmcLANInterfaceStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 5 Description Defines the state settings of the BMC LAN interface Syntax DellStateSettings Access Read write 530 Baseboard Management Controller Group BMC LAN Interface Status Name Object ID Description Syntax Access bmcLANInterfaceStatus 1 3 6 1 4 1 674 10892 1 1900 30 1 6 Defines the status of the BMC LAN interface DellStatus Read only BMC LAN Interface Channel Number
11. Description Describes the schedule number information Syntax DellCostofOwnershipString Access Read write COO Options Table Name cooOptionsTable Object ID 1 3 6 1 4 1 674 10892 1 1600 70 Description Defines the COO Options Table Syntax SEQUENCE OF CooOptionsTableEntry Access Not accessible 448 Cost of Ownership Group COO Options Table Entry Name Object ID Description Syntax Access Index cooOptionsTableEntry 1 3 6 1 4 1 674 10892 1 1600 70 1 Defines the COO Options Table entry CooOptions TableEntry Not accessible cooOptionschassisIndex cooOptionsIndex COO Options Chassis Index Name cooOptionschassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only COO Options Index Name cooOptionsIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 2 Description Defines the index one based of the option information for this system Syntax DellObjectRange Access Read only COO Options State Name cooOptionsState Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 3 Description Defines the option information state for this system Syntax DellStateSettings Access Read only Cost of Ownership Group 449 COO Options Lease Information Index Reference Name Object ID Description Syntax Access cooOptionsLeaseInformationIndexReference 1 3 6 1 4 1 674 10892 1 1600 70 1 4 Defines the lease info
12. Name Object ID Description Syntax Access controllerPhysicalDeviceCount 1 3 6 1 4 1 674 10893 1 20 130 1 1 11 Identifies the number of physical devices on the controller channel including both disks and the controller Integer Read only Storage Management Group 557 Controller Logical Device Count Name controllerLogicalDeviceCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 12 Description Identifies the number of virtual disks on the controller Syntax Integer Access Read only Controller Partner Status Name controllerPartnerStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 13 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only Controller Host Port Count Name controllerHostPortCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 14 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller Memory Size in Megabytes Name controllerMemorySizeInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 15 Description Identifies the size of memory in megabytes on the controller If this size is 0 it is less than a megabyte This attribute is only supported on Adaptec controllers Syntax Integer Access Read only 558 Storage Management Group Controller Memory Size in Bytes Name Object ID Description Syntax Access controllerMemorySizelInBytes 1 3 6 1 4 1 674 10893 1 20
13. Possible Data Values Meaning of Data Value If set to 0 zero There are no logging capabilities unknown Capabilities 1 Logging capabilities are unknown The logging capabilities are enableCapable 2 Logging enable disable using Simple Network Management Protocol SNMP is supported Memory Group _ 381 Table 15 8 Physical Memory Logging Settings Variable Name De 1 1 PhysicalMemoryLoggingSettings Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero There are no logging settings enabled unknown Capabilities 1 Logging capabilities are unknown The logging settings are enabled 2 Logging is disabled 0 or enabled 1 382 Memory Group BIOS Setup Control Group Basic Input Output System BIOS Setup Control Group variables provide information about the functions that the BIOS performs in your system This management information base MIB group includes variables for the boot sequence speakers diskettes ports network interface controllers NICs and the Wakeup on local area network LAN feature BIOS Group Tables The objects in this group define the BIOS control of devices and controller cards that are typically present in a system The following MIB tables define the BIOS Setup Control Group BIOS Setup Control Table SCSI Control Table Parallel Port Control Table Serial Port Control Table USB Control Table IDE Control Table Diskette Contro
14. Syntax UUIDTableEntry Access Not accessible Index uUID Index uUIDchassisIndex UUID Chassis Index Name uUIDchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only UUID Index Name uUIDIndex Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 2 Description Defines the index of the UUID in a specified chassis Syntax DellObjectRange Access Read only UUID Type Name uUIDType Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 3 Description Defines the type of the UUID for this chassis Syntax DellUUIDType Access Read only Chassis Information Group 85 UUID Value Name uUIDValue Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 4 Description Defines the value of the UUID for this chassis Syntax OCTET STRING SIZE 16 Access Read only POST Log Table This section defines attributes for the power on self test POST log When you turn on your computer the POST checks various system components before the operating system loads The POST tests the random access memory RAM the hard drives and the keyboard for example While the POST is running it makes a log file that system administrators can view The variables in this section also contribute to managing the POST log Name postLogTable Object ID 1 3 6 1 4 1 674 10892 1 300 30 Description Defines the POST Log Table Syntax SEQUENCE OF PostLogTableEntry Access Not accessible P
15. User Security User Name Name userSecurityUserName Object ID 1 3 6 1 4 1 674 10892 1 800 1 3 Description Defines the user security user name Syntax DellSecurityString Access Read only User Security Control Name Name userSecurityControlName Object ID 1 3 6 1 4 1 674 10892 1 800 1 4 Description Defines a control name used for creating deleting and editing users Syntax DellSecurityString Access Read write 216 User Security Group User Security Request Name Name userSecurityRequestName Object ID 1 3 6 1 4 1 674 10892 1 800 1 5 Description Defines a request name used for creating deleting and editing users Syntax DellSecurityString Access Read write User Security Group 217 218 User Security Group Remote Flash BIOS Group The Remote Flash Basic Input Output System BIOS Table defines the variables used to remotely update the BIOS in a system The variables also define the capabilities of BIOS updates on the system Remote Flash BIOS Group Table The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table Remote Flash BIOS Table The following object sets up the Remote Flash BIOS Table Name remoteF lashBIOSTable Object ID 1 3 6 1 4 1 674 10892 1 900 10 Description Defines the Remote Flash BIOS Table Syntax RemoteFlashBIOSTableEntry Access Not accessible Remote Flash BIOS Table Entry Name remoteFlashBlOSTableEntry Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 Des
16. 309 Managed System Services Device Index Name managedSystemServicesDeviceIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 100 1 2 Description Defines the index one based of the managed system services device Syntax DellObjectRange Access Read only Managed System Services Device Status Name managedSystemServicesDeviceStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 100 1 3 Description Defines the status of the managed system services device Syntax DellStatus Access Read only Managed System Services Device Type Name managedSystemServicesDeviceTyp Object ID 1 3 6 1 4 1 674 10892 1 1100 100 1 4 Description Defines the type of the managed system services device Syntax DellManagedSystemServicesDeviceType See Table 13 25 Access Read only 310 Device Group Managed System Services Device Storage Present Name managedSystemServicesDeviceStoragePresent Object ID 1 3 6 1 4 1 674 10892 1 1100 100 1 5 Description Defines whether storage is present on the managed system services device Syntax DellBoolean Access Read only Managed System Services Device Storage Size Name managedSystemServicesDeviceStorageSiz Object ID 1 3 6 1 4 1 674 10892 1 1100 100 1 6 Description Defines the size in Megabytes MB of the storage present on the managed system services device Syntax DellUnsigned32BitRange Access Read only SD Card Unit Table Name sdCardUnitTable Object ID 1 3 6 1 4 1 674 10892 1 1100 110 Descri
17. Chassis Information Group 97 Firmware State Capabilities Name firmwareStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 3 Description Defines the capabilities of the firmware states Syntax DellStateCapabilities Access Read only Firmware State Capabilities Name firmwareStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 4 Description Defines the state of the firmware and allows for the setting of the firmware Syntax DellStateSettings Access Read write Firmware Status Name firmwareStatus Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 5 Description Defines the status of the firmware Syntax DellStateSettings Access Read only Firmware Size Name firmwareSize Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 6 Description Defines the image size of the firmware in KB A zero 0 indicates that the size is unknown Syntax DellUnsigned16BitRange Access Read only 98 Chassis Information Group Firmware Type Name Object ID Description Syntax Access firmwareType 1 3 6 1 4 1 674 10892 1 300 60 1 7 Defines the type of the firmware DellFirmwareType Read only Firmware Type Name Name Object ID Description Syntax Access firmwareTypeName 1 3 6 1 4 1 674 10892 1 300 60 1 8 Defines the name of firmware type DellString Read only Firmware Update Capabilities Name Object ID Description Syntax Access firmwareUpdateCapabilities 1 3 6 1 4 1 674 10892 1 300 60 1 9 Defin
18. Defines the index of system resource maps in this chassis DellObjectRange Read only Map State Capabilities systemResourceMapStateCapabilities 1 3 6 1 4 1 674 10892 1 500 10 1 3 Defines the capabilities of this system map DellStateCapabilities Read only System Resource Group System Resource Map State Settings Name systemResourceMapStateSettings Object ID 1 3 6 1 4 1 674 10892 1 500 10 1 4 Description Defines the state and allows the setting of this system map Syntax DellStateSettings Access Read write System Resource Map Status Name systemResourceMapStatus Object ID 1 3 6 1 4 1 674 10892 1 500 10 1 5 Description Defines the status of this system map Syntax DellStatus Access Read only System Resource Map Type Name systemResourceMapTyp Object ID 1 3 6 1 4 1 674 10892 1 500 10 1 6 Description Defines the type of this system map Syntax DellSystemResourceMapType See Table 7 1 Access Read only System Resource Owner Table Name systemResourceOwnerTabl Object ID 1 3 6 1 4 1 674 10892 1 500 20 Description Defines the System Resource Owner Table Syntax SEQUENCE OF SystemResourceOwner TableEntry Access Not accessible System Resource Group 129 System Resource Owner Table Entry Name Object ID Description Syntax Access Index systemResourceOwnerTabl 1 3 6 1 4 1 674 10892 1 500 20 1 Defines the System Resource Owner Table entry Variables in this group reference the System Resou
19. DellCacheDeviceLocation See Table 13 13 Read only Cache Device Status State Name Object ID Description Syntax Access cacheDeviceStatusState 1 3 6 1 4 1 674 10892 1 1100 40 1 9 Defines the status state of the cache device DellCacheDeviceStatusState See Table 13 10 Read only Cache Device External Socket Name Name Object ID Description Syntax Access cacheDeviceExternalSocketName 1 3 6 1 4 1 674 10892 1 1100 40 1 10 Defines the external socket name of the cache device if the cache is socketed DellString Read only Cache Device Level Name Object ID Description Syntax Access 278 cacheDeviceLevel 1 3 6 1 4 1 674 10892 1 1100 40 1 11 Defines the level of the cache device DellCacheDeviceLevel See Table 13 8 Read only Device Group Cache Device Maximum Size Name cacheDeviceMaximumSize Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 12 Description Defines the maximum size of the cache device in kilobytes KB A zero 0 indicates that the size is unknown Syntax DellUnsigned32BitRange Access Read only Cache Device Current Size Name cacheDeviceCurrentSiz Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 13 Description Defines the current size of the cache device in KB A zero 0 indicates that the size is unknown Syntax DellUnsigned32BitRange Access Read only Cache Device Speed Name cacheDeviceSpeed Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 14 Description De
20. Description Defines the timestamp of the most recent chassis minimum power usage Syntax DellPowerReading Access Read only DRsWattsResetTime Name DRsWattsResetTime Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 12 Description Defines the timestamp of the most recent reset of the chassis minimum maximum Watts readings Syntax DellTimestamp Access Read only 684 Dell RAC Out of Band Group DRsWattsReading Name Object ID Description DRsWattsReading 1 3 6 1 4 1 674 10892 2 4 1 1 13 Defines the instantaneous chassis power usage in Watts Syntax DellPowerReading Access Read only DRsAmpsReading Name DRsAmpsReading Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 14 Description Syntax Access Defines the instantaneous chassis current usage in Watts DellPowerReading Read only CMC PSU Information The following MIB tables provide information on the chassis power supply unit DRsPSUChassisIndex Name DRsPSUChassisIndex Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 1 Description Syntax Access Defines the index one based of the associated chassis DellCMCPowerIndexRange Read only Dell RAC Out of Band Group 685 DRsPSUIndex Name DRsPSUIndex Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 2 Description Defines the index one based of the associated CMC PSU Syntax DellCMCPSUIndexRange Access Read only DRsPSULocation Name DRsPSULocation Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 3 Description Defines the
21. Description Indicates whether the controller s write cache will be used when writing to a virtual disk Possible values 1 Enabled Adaptec Write Cache Enabled Protected 2 Disabled Adaptec Write Cache Disabled 3 LSI Write Back 4 LSI Write Through 5 Enabled Always Adaptec only 6 Enabled Always SAS only Syntax Integer Access Read only Storage Management Group 645 Virtual Disk Read Policy Name virtualDiskReadPolicy Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 11 Description Indicates whether the controller s read cache will be used when reading from a virtual disk Possible values 1 Enabled Adaptec Read Cache Enabled 2 Disabled Adaptec Read Cache Disabled 3 LSI Read Ahead 4 LSI Adaptive Read Ahead 5 LSI No Read Ahead Syntax Integer Access Read only Virtual Disk Cache Policy Name virtualDiskCachePolicy Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 12 Description Indicates whether the controller s cache is used when reading from or writing to a virtual disk Possible values 1 Direct I O LSI 2 Cached I O LSI 99 Not Applicable Syntax Integer Access Read only 646 Storage Management Group Virtual Disk Layout Name virtualDiskLayout Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 13 Description Indicates the virtual disk s RAID type Possible values 1 Concatenated 2 RAID 0 3 RAID 1 7 RAID 5 8 RAID 6 10 RAID 10 12 RAID 50 19 Concatenated RAID 1 24 RAID 60 Syntax
22. Management Syntax Integer Access Read only Controller CO Target Name controllerC0OTarget Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 22 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only 560 Storage Management Group Controller CO Channel Name controllerCOChannel Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 23 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller CO Operating System Controller Name controllerCO0OSController Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 24 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller CO Battery State Name controllerCO0BatteryState Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 25 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller C1 Port 0 World Wide Name Name controllerC1Port OWWN Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 26 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Storage Management Group 561 Controller C1 Port 0 Name Name controllerC1Port0Name Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 27 Description This entry is obsolete Fibre chan
23. Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 14 Description Defines the control settings of this remote access SNMP trap destination Syntax DellRemoteSNMPTrapControlSettings See Table 19 21 Access Read write Remote Access Group _ 489 Remote Dial Up Table Name Object ID Description Syntax Access remoteDialUpTable 1 3 6 1 4 1 674 10892 1 1700 40 Defines the Remote Access Dial Up Table SEQUENCE OF RemoteDialUpTableEntry Not accessible Remote Dial Up Table Entry Name Object ID Description Syntax Access Index remoteDialUpTableEntry 1 3 6 1 4 1 674 10892 1 1700 40 1 Defines the Remote Access Dial Up Table entry RemoteDialUpTableEntry Not accessible remoteDialUpChassisIndex remoteDialUpAdapterIndex remoteDialUpIndex Remote Dial Up Chassis Index Name Object ID Description Syntax Access remoteDialUpChassisIndex 1 3 6 1 4 1 674 10892 1 1700 40 1 1 Defines the index one based of the chassis containing the remote access hardware DellObjectRange Read only 490 Remote Access Group Remote Dial Up Adapter Index Name remoteDialUpAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 2 Description Defines the index one based of the remote access hardware that supports this remote access dial up functionality Syntax DellObjectRange Access Read only Remote Dial Up Index Name remoteDialUpIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 3 Description Defines t
24. Read write System Resource Interrupt Status Name Object ID Description Syntax Access systemResourceInterruptStatus 1 3 6 1 4 1 674 10892 1 500 50 1 5 Defines the status of this system resource interrupt DellStatus Read only System Resource Group 139 System Resource Interrupt Owner Index Reference Name systemResourcelInterruptOwnerIndexReferenc Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 6 Description Defines the index for the associated system resource owner in this chassis Syntax DellObjectRange Access Read only System Resource Interrupt Owner Share Disposition Name systemResourcelInterruptShareDisposition Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 7 Description Defines the share disposition of the system resource interrupt Syntax DellResourceShareDisposition See Table 7 3 Access Read only System Resource Interrupt Level Name systemResourcelInterruptLevel Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 8 Description Defines the interrupt request IRQ level of the system resource interrupt Syntax DellUnsigned32BitRange Access Read only System Resource Interrupt Type Name systemResourcelInterruptType Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 9 Description Defines the interrupt type of the system resource interrupt Syntax DellResourcelnterruptType See Table 7 5 Access Read only 140 System Resource Group System Resource Interrupt Trigger Name Object ID Descr
25. Remote Access Host Settings Name remoteAccessHostSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 17 Description Defines the host settings of the remote access hardware Syntax DellRemoteAccessHostSettings See Table 19 9 Access Read write Remote Access Out of Band Simple Network Management Protocol SNMP Capabilities Name remoteAccessOutOfBandSNMPCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 18 Description Defines the out of band SNMP capabilities of the remote access hardware Syntax DellRemoteAccessOutOfBandSNMPCapabilities See Table 19 10 Access Read only 472 Remote Access Group Remote Access Out of Band SNMP Settings Name remoteAccessOutOfBandSNMPSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 19 Description Defines the out of band SNMP settings of the remote access hardware Syntax DellRemoteAccessOutOfBandSNMPSettings See Table 19 11 Access Read write Remote Access Simple Mail Transfer Protocol SMTP Server Internet Protocol IP Address Name remoteAccessSMTPServerIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 20 Description Defines the IP address for the SMTP server used by the remote access hardware Syntax IpAddress Access Read write Remote Access Floppy Trivial File Transfer Protocol TFTP IP Address Name remoteAccessFloppyTFTPIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 21 Description Defines the IP address of the TFTP server providing the op
26. SI deviceFamilyIsAMDPhenomII 236 The processor family is AMD Phenom TM II deviceFamilyIsAMDAthlonII 237 The processor family is AMD Athlon TM IL deviceFamilyIsSixCoreAMDOptero The processor family is Six Core AMD n 238 Opteron deviceFamilyIsAMDSempronM 239 The processor family is AMD Sempron TM M deviceFamilyIsi860 250 The processor family is i860 deviceFamilyIsi960 251 The processor family is 1960 330 Device Group Table 13 7 Cache Device Type Variable Name De 1 1CacheDeviceType Data Type Integer Possible Data Values Meaning of Data Value devic TypelsOther 1 System cache type is not one of the following deviceTypelIsUnknown 2 System cache type is unknown deviceTypelIsInstruction 3 System cache type is instruction deviceTypelIsData 4 System cache type is data deviceTypelIsUnified 5 System cache type is both instruction and data Table 13 8 Cache Device Level Variable Name De 1 1CacheDeviceLevel Data Type Integer Possible Data Values Meaning of Data Value deviceLevellsOther 1 Device level is not one of the following deviceLevellIsUnknown 2 Device level is unknown deviceLevellIsPrimary 3 Device level is primary devic LevellIsSecondary 4 Device level is secondary devic LevellIsTertiary 5 Device le
27. Systems Management Software Group The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis The Systems Management Software Group classifies each computer chassis according to the systems management standard that the agent supports Additional objects define the universal resource locator URL of the systems management software and the language in which systems management information displays Defining these objects enables users to manage a system using an internet browser You can access Server Administrator using the secure hypertext transfer protocol https and a pre assigned port number of 1311 or you can specify a port number of your own choosing K NOTE Using the Software Server Preferences menu of Server Administrator you can bind to either one IP address or to all IP addresses K NOTE To manage a system remotely using Server Administrator type one of the following in the address field of your browser https lt systemname gt lt 1311 or user specified port number gt Ox https lt IP address gt lt 1311 or user specified port number gt To manage a system locally using Server Administrator type the following in the address field of your browser https localhost lt 1311 or user specified port number gt Systems Management Software Group 45 Systems Management Software The
28. The previous global status of the system managed by the Storage Management software Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Agent Smart Thermal Shutdown Name Object ID Description Syntax Access agentSmartThermalShutdown 1 3 6 1 4 1 674 10893 1 20 110 15 Indicates the status of smart thermal shutdown for PowerVault 220S and PowerVault 221S enclosures Possible values 1 Enabled 2 Disabled 3 Not applicable Integer Read only Storage Management Group __ 551 Physical Devices Group The Physical Devices MIB group provides information about the devices managed by the Storage Management software and their relationships to each other The following MIB tables define objects and relationships connections among the objects 552 Controller Table describes available properties for each controller on the managed system Channel Table describes available properties for each channel on the managed system Enclosure Table describes available properties for each enclosure on the managed system Array Disk Table describes available properties for each physical array disk on the managed system Array Disk Enclosure Connection Table describes the connections between Fibre Channel array disks their enclosure and their associated controller For each object in the table its object number corresponds to an i
29. Variable Name De 1 1MemoryDeviceFormFactor Data Type Integer Possible Data Values Meaning of Data Value deviceFormFactorIsOther 1 Device form factor is not one of the following deviceFormFactorIsUnknown 2 Device form factor is unknown deviceFormFactorIsSIMM 3 Device form factor is SIMM deviceFormFactorIsSIP 4 Device form factor is SIP deviceFormFactorIsAChip 5 Device form factor is a chip deviceFormFactorIsDIP 6 Device form factor is DIP deviceFormFactorIsZIP 7 Device form factor is ZIP deviceFormFactorIsAProprietaryCard Device form factor is a proprietary 8 card deviceFormFactorIsDIMM 9 Device form factor is DIMM deviceFormFactorIsTSOP 10 Device form factor is TSOP Device Group 335 Table 13 15 Memory Device Type Form Factor continued Variable Name Del 1MemoryDevic Data Type Integer FormFactor Possible Data Values Meaning of Data Value deviceFormFactorIsARowOfChips 11 Device form factor is a row of chips deviceFormFactorIsRIMM 12 Device form factor is RIMM deviceFormFactorIsSODIMM 13 Device form factor is SODIMM deviceFormFactorIsSRIMM 14 Device form factor is SRIMM deviceFormFactorIsFBDIMM 15 Device form factor is FB DIMM Table 13 16 Memory Device Type Variable Name Del 1MemoryDevic Data Type Integer Typ Possible Data Values Meaning of Data Value
30. connectorPortTypelsOther 1 The SCSI port connector type is not one of the following connectorPortTypelIsUnknown 2 The SCSI port connector type is unknown connectorPortTypeIsDIN25pin 3 The SCSI port connector type is a DIN 25 pin connectorPortTypeIsDIN50pin 4 The SCSI port connector type is a DIN 50 pin connectorPortTypeIsDIN68pin 5 The SCSI port connector type is a DIN 68 pin 258 Port Group Device Group The Device Group provides information about different types of pointing keyboard processor cache memory and peripheral component interconnect PCI devices Variables in this group cover information about type settings configuration manufacturer address or location and if applicable the speed of the device Device Tables The following management information base MIB tables define objects in the Device Group Pointing Device Table Keyboard Device Table Processor Device Table Processor Device Status Table Cache Device Table Memory Device Table Memory Device Mapped Address Table Generic Device Table PCI Device Table PCI Device Configuration Space Table Network Device Table Managed System Services Device Table SD Card Unit Table SD Card Device Table Device Group 259 Pointing Device Table Name Object ID Description Syntax Access pointingDeviceTable 1 3 6 1 4 1 674 10892 1 1100 10 Defines the Pointing Device Table This group of objects references the Pointin
31. specified system is in a throttled state The sensor location chassis location previous state and processor sensor status are provided Table 26 14 Processor Device Status Traps continued Cause Trap ID Description Severity Processor Device Status Failure 1604 Processor sensor Error detected a failure value Sensor Location lt Location in chassis gt Chassis Location lt Name of chassis gt Previous state was lt State gt Processor sensor status lt status gt A processor sensor in the specified system is disabled has a configuration error or experienced a thermal trip The sensor location chassis location previous state and processor sensor status are provided Pluggable Device Traps Server Administrator monitors the addition and removal of pluggable devices such as memory cards Device traps provide information about the addition and removal of such devices Table 26 15 Pluggable Device Traps Trap ID Description Severity Cause Pluggable Device Addition 1651 Device added to system Information Device Location lt Location in chassis gt Chassis Location lt Name of chassis gt Additional Details lt Additional details for the events gt A device was added to the specified system The device location chassis location and additional event details if available are provided Traps 721 Table 26 15 Pluggable Device Traps continued
32. 18 Contents Introduction This introduction is divided into two sections The first section Introduction to the SNMP Reference Guide explains the SNMP Reference Guide design All essential Simple Network Management Protocol SNMP terms are defined in this section Some of the vocabulary may seem complex and unfamiliar to system administrators who are using SNMP for the first time SNMP experts can skim this section and beginners can read the section more carefully The second section Introduction to the Server Administrator SNMP Subagent is a more technical introduction to the management information base MIB that underlies Server Administrator services Audience This guide is intended for system administrators network administrators and anyone who wants to write SNMP MIB applications to monitor systems What s New in this Release This section lists the SNMP versions supported and changes to the Server Administrator MIBs in this release Supported SNMP Versions Operating System Supported SNMP version Windows SNMP vl and v2c Linux SNMP vl v2c and v3 What s New in System State Group Added the following MIB objects to the System State table e systemStateS DCardUnitStatusCombined e systemStateSDCardUnitStatusList e systemStateS DCardDeviceStatusCombined e systemStateS DCardDeviceStatusList Introduction 19 What s New in Device Group e Added the following MIB objects to the Secure Digital S
33. 3 Sys MIB Major VersionNumber MIB Minor VersionNumber MIB Maintenance Version Number tems Management Software Group Contents Systems Management Software Systems Management SoftwareName Systems Management Software VersionNumberName Systems Management Software Build Number 2 Systems Management Software Description Name 00 4 Systems Management Software Supported Protocol Systems Management Software Preferred Protocol Systems Management Software Update Level Name Systems Management Software URLName o seanina ho a O a a Systems Management Software Language Name 48 Systems Management Software Global VersionName 48 Systems Management Software Feature Flags aoaaa aaa 48 Systems Management Software SNMP Agent Feature Flags 49 Systems Management Software ManufacturerName 49 Systems Management Software Variable Values 49 4 System State Group 51 System StateGroupTable 51 System StateTable 51 5 Chassis Information Group 71 Chassis Information Group Tables n Chassis Information Table naaa 71 WUID Tablet ii a a a aaa Sn RES 84 POSTLogTable 86 EventLogTable 88 System BIOS
34. 4 The admin user can support sending a test alphanumeric page emailTestCapable 8 The admin user can support sending a test e mail Remote Access Group 507 Table 19 15 Remote User Admin Control Settings Variable Name De 1 1RemoteUserAdminControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The admin user has no control settings unknown 1 The admin user control settings are unknown numericPagerTest 2 Anumeric pager test will be performed for the admin user alphaPagerTest 4 An alphanumeric pager test will be performed for the admin user emailTest 8 An e mail test will be performed for the admin user Table 19 16 Remote User Admin Alpha Protocol Type Variable Name De 1 1RemoteUserAdminAlphaProtocolType Data Type Integer Possible Data Values Meaning of Data Value other 1 The remote user admin alpha protocol type is not one of the following unknown 2 The remote user admin alpha protocol type is unknown alpha7E0 3 The remote user admin alpha protocol type is 7E0 alpha8N1 4 The remote user admin alpha protocol type is 8N1 508 Remote Access Group Table 19 17 Remote User Admin Alpha Baud Type Variable Name De 1 1Remot eUserAdminAlphaBaudType Data Type Integer Possible Data Values Meaning of Data Value other 1 The remote user alphanumeric baud rate is not one of the follow
35. COO Repair Chassis Index Name Object ID Description cooRepairchassisIndex 1 3 6 1 4 1 674 10892 1 1600 90 1 1 Defines the index one based of this chassis Syntax DellObjectRange Access Read only COO Repair Index Name cooRepairiIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 90 1 2 Description Defines the index one based of the repair information for this system Syntax DellObjectRange Access Read only COO Repair State Name cooRepairState Object ID 1 3 6 1 4 1 674 10892 1 1600 90 1 3 Description Defines the state of the repair information for this system Syntax DellStateSettings Access Read only Cost of Ownership Group 453 COO Repair Counter Name cooRepairCounter Object ID 1 3 6 1 4 1 674 10892 1 1600 90 1 4 Description Defines the number of repairs that this system has undergone Syntax DellCostofOwnershipString Access Read write COO Repair Vendor Name Name cooRepairVendorName Object ID 1 3 6 1 4 1 674 10892 1 1600 90 1 5 Description Defines the name of the vendor that repairs this system Syntax DellStateSettings Access Read only COO Support Information Table Name cooSupportiInformationTable Object ID 1 3 6 1 4 1 674 10892 1 1600 100 Description Defines the COO Support Information Table Syntax SEQUENCE OF cooSupportInformationTableEntry Access Not accessible COO Support Information Table Entry Name cooSupportiInformationTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 100
36. Channel Data Rate Name channelDataRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 10 Description Identifies the data rate of this channel Syntax DisplayString Access Read only Channel Bus Type Name channelBusType Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 11 Description The bus type of the channel Possible values 1 SCSI 2 IDE 3 Fibre Channel 4 Serial Storage Architecture SSA 6 Universal Serial Bus USB 7 SATA 8 SAS Syntax Integer Access Read only 574 Storage Management Group Enclosure Table This table describes available properties for each enclosure on the managed system The following object sets up the Enclosure Table Name enclosureTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 Description Defines the enclosure table Syntax SEQUENCE OF EnclosureEntry Access Not accessible Enclosure Entry Name enclosureEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 Description Defines the enclosure table entry Syntax EnclosureEntry Access Not accessible Index enclosureNumber Enclosure Number Name enclosureNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 1 Description Identifies the instance number of the enclosure entry Syntax Integer Access Read only Storage Management Group 575 Enclosure Name Name enclosureName Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 2 Description Identifies the enclosure s name as represented in Storage Management Syntax Display
37. Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 44 Description The minimum firmware version for Storage Management to support the controller Syntax DisplayString Access Read only Controller Minimum Driver Version Name controllerMinDriverVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 45 Description The minimum driver version for Storage Management to support the controller Syntax DisplayString Access Read write Controller SCSI Initiator ID Name controllerSCSIInitiatorID Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 46 Description The SCSI ID of the initiator Syntax Integer Access Read only Controller Channel Count Name controllerChannelCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 47 Description The number of channels on the controller Syntax Integer Access Read only Storage Management Group 567 Controller Reconstruct Rate Name controllerReconstructRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 48 Description The rate for reconstruct on the controller Syntax Integer Access Read write Controller Patrol Read Rate Name controllerPatrolReadRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 49 Description The rate for patrol read on the controller Syntax Integer Access Read only Controller BGI Rate Name controllerBGIRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 50 Description The rate for background initialization
38. Storage Management Group 577 Enclosure Asset Tag Name enclosureAssetTag Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 9 Description Customer definable asset tag for the enclosure Syntax DisplayString Access Read only Enclosure Asset Name Name enclosureAssetName Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 10 Description Customer definable asset name of the enclosure Syntax DisplayString Access Read only Enclosure Split Bus Part Number Name enclosureSplitBusPartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 11 Description Identifies the enclosure s split bus part number Syntax DisplayString Access Read only Enclosure Product ID Name enclosureProductID Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 12 Description Identifies the enclosure s product identification This also corresponds to the enclosure type Syntax DisplayString Access Read only 578 Storage Management Group Enclosure Kernel Version Name enclosureKernelVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 13 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only Enclosure ESM1 Part Number Name enclosureESM1PartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 14 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only Enclosure ESM2 Part Number Name enclosureESM2PartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 15 Descript
39. The memory array is nonvolatile RAM memoryArray UselsCacheMemory 7 The memory array is cache memory Memory Group _ 377 Table 15 1 Physical Memory Array Location continued Variable Name De11PhysicalMemoryArrayLocation Data Type Integer Possible Data Values Meaning of Data Value memoryArrayLocationIsPCMCIA 8 The memory array location is a Personal Computer Memory Card International Association PCMCIA option card memoryArrayLocationIsProprietary 9 The memory array location is a proprietary option card memoryArrayLocationIsNUBUS 10 The memory array location is a NuBus bus memoryArrayLocationIsPC98C20 11 The memory array location is a PC 98 C20 option card memoryArrayLocationIsPC98C24 12 The memory array location is a PC 98 C24 option card memoryArrayLocationIsPC98E 13 The memory array location is a PC 98 E option card memoryArrayLocationIsPC98LocalBus 14 The memory array location is a PC 98 Local bus option card memoryArrayLocationIsPC98Card 15 The memory array location is a PC 98 Card slot option card 378 Memory Group Table 15 2 Physical Memory Array ECC Type Definitions Variable Name De 1 1PhysicalMemoryArrayECCType Data Type Integer Possible Data Values Meaning of Data Value memoryArrayECCTypelIsOther 1 There is not one of the following memoryArrayECCTypelsUnknown 2 The memo
40. Unable to determine connection status connected 1 Media reports that device is connected Device Group 339 Table 13 20 Network Device Connection Status Variable Name De 1 1NetworkDeviceConnectionStatus Data Type Integer Possible Data Values Meaning of Data Value disconnected 2 Media reports that device is disconnected driverBad 3 Driver cannot be opened to determine status driverDisabled 4 Driver is disabled hardwareInitalizing 10 Hardware is initializing hardwareResetting 11 Hardware is resetting hardwareClosing 12 Hardware is closing down hardwareNot Ready 13 Hardware is not ready Table 13 21 Network Device Teaming Flags Variable Name De 1 1NetworkDeviceTeamingFlags Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value undefined 0 Teaming flags are undefined noTeam 1 Device is not part of any team teamingEnabled 2 Teaming is enabled adapterFaultToleranceMode 4 Adapter fault tolerance teaming mode loadBalancingMode 8 Load balancing teaming mode Table 13 22 Network Device TOE Capability Flags Variable Name De 1 1NetworkDeviceTOECapabilityFlags Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 Querying for TOE capability is n
41. also defines thermal shutdown capabilities and settings In the event that a temperature probe determines the temperature is at or over the failure limit the systems manager can set an action to be taken automatically Local Response Agent Group 419 LRA Global Settings Table Name 1LRAGlobalSettingsTable Object ID 1 3 6 1 4 1 674 10892 1 1500 10 Description Defines the LRA Global Settings Table Syntax SEQUENCE OF LRAGlobalSettingsTableEntry Access Not accessible LRA Global Settings Table Entry Name 1RAGlobalSettingsTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1500 10 1 Description Defines the LRA Global Settings Table entry Syntax LRAGlobalSettingsTableEntry Access Not accessible Index IRAGlobalchassisIndex LRA Global Chassis Index Name 1RAGlobalchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1500 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only LRA Global State Name 1RAGlobalState Object ID 1 3 6 1 4 1 674 10892 1 1500 10 1 2 Description Defines the state of the LRA global settings Syntax DellStateSettings Access Read only 420 Local Response Agent Group LRA Global Settings Disable Time out Value Name Object ID Description Syntax Access 1RAGlobalSettingsDisableTimeoutValue 1 3 6 1 4 1 674 10892 1 1500 10 1 3 Defines the time out duration countdown in seconds that the LRA global settings will be disabled after a system shutdown a
42. indicates that the image size of the BIOS is unknown Syntax DellUnsigned32BitRange Access Read only 92 l Chassis Information Group System BIOS Release Date Name Name systemBIOSReleaseDateNam Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 7 Description Defines the release date of the system BIOS Syntax DellDateName Access Read only System BIOS Version Name Name systemB1IO0SVersionName Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 8 Description Defines the version name of the system BIOS Syntax DellString Access Read only System BIOS Starting Address Name Object ID Description Syntax Access systemB1I0SStartingAddress 1 3 6 1 4 1 674 10892 1 300 50 1 9 Defines the starting address of the system BIOS A zero 0 indicates that the address is unknown DellUnsigned64BitRange Read only System BIOS Ending Address Name Object ID Description Syntax Access systemBIOSEndingAddress 1 3 6 1 4 1 674 10892 1 300 50 1 10 Defines the ending address of the system BIOS A zero 0 indicates that the address is unknown DellUnsigned64BitRange Read only Chassis Information Group 93 System BIOS Manufacturer Name Name systemBIOSManufacturerName Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 11 Description Defines the system BIOS manufacturer s name Syntax DellString Access Read only System BIOS Characteristics Name systemBIOSCharacteristics Object ID 1 3 6 1 4 1 674 10892 1 300 50
43. s operating system Identifying information includes the name version service pack and patch level of the installed operating system Operating System Group Table The following management information base MIB tables define the objects in the Operating System Group e Operating System Table e Operating System Memory Table Operating System Table The following object sets up the Operating System Table Name operatingSystemTable Object ID 1 3 6 1 4 1 674 10892 1 400 10 Description Defines the Operating System Table Syntax SEQUENCE OF OperatingSystemTableEntry Access Not accessible Operating System Table Entry Name operatingSystemTableEntry Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 Description Defines the Operating System Table entry Syntax OperatingSystem TableEntry Access Not accessible Index operatingSystemchassisIndex Operating System Group 121 Operating System Chassis Index Name operatingSystemchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 1 Description Defines the index one based of the associated chassis Syntax DellObjectRange Access Read only Operating System State Capabilities Name operatingSystemStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 2 Description Defines the capabilities of the operating system Syntax DellStateCapabilities Access Read only Operating System State Settings Name operatingSystemStateSettings Object ID 1 3 6 1 4 1 674 10892 1 400 10
44. 1 300 1 oOo OC GO Oo O O GO aO On Oe G O Ga Oe Oe Oe one 20 1 A N L221 Lv Si8 1 24 1 e236 L L 26 1 Leek 1 28 1 L224 1 30 1 be dtvel 1 See P3301 1 34 1 l3 SL 289 ERVER01 lease set As lease set lease set Oo Oo 0 0 0 0 0 ODO W 1 3 6 1 4 1 674 10892 1 300 1 1 3 6 1 4 1 674 10892 1 300 1 1 3 6 1 4 1 674 10892 1 300 1 1 3 6 1 4 1 674 10892 1 300 1 1 3 6 1 4 1 674 10892 1 300 1 1 3 6 1 4 1 674 10892 1 300 1 1 3 6 1 4 1 674 10892 1 300 1 3 6 1 4 1 674 10892 1 300 1 3 6 1 4 1 674 10892 1 300 1 3 6 1 4 1 674 10892 1 300 1 3 6 1 4 1 674 10892 1 300 cleared 1 3 6 1 4 1 674 10892 1 300 1 3 6 1 4 1 674 10892 1 300 1 3 6 1 4 1 674 10892 1 300 20050513100047 000000 360 0 1 36 1 480 Organs Pag ay gt vile 0 1 38 1 2 0 1 39 1 2 0 1 44 1 0 0 1 45 1 0 Orly 1 Oa L2 1 Qals 8 0 1 4 2 Od hog 0 1 6 2 0 1 7 3 Ord 8 SNMP Sample Output 753 754 l SNMP Sample Output Index Numerics 1403 716 1404 716 1602 720 1603 720 1604 721 1651 721 1652 722 1653 722 A Application 660 Application Group 660 BIOS Group BIOS Setup Control Table 383 Diskette Control Table 404 IDE Control Table 402 Network Interface Control Table 406 Parallel Port Control Table 396 SCSI Control Table 394 Serial Port Control Table 398 USB Control Table 400 BIOS Group tables 38
45. 1 Description Defines the COO Support Information Table entry Syntax cooSupportInformationTableEntry Access Not accessible Index cooSupportInformationchassisIndex cooSupportInformationIndex 454 Cost of Ownership Group COO Support Information Chassis Index Name Object ID Description Syntax Access cooSupportInformationchassisIndex 1 3 6 1 4 1 674 10892 1 1600 100 1 1 Defines the index one based of this chassis DellObjectRange Read only COO Support Information Index Name Object ID Description Syntax Access cooSupportInformationIndex 1 3 6 1 4 1 674 10892 1 1600 100 1 2 Defines the index one based for this system s support information DellObjectRange Read only COO Support Information State Name Object ID Description Syntax Access cooSupportInformationState 1 3 6 1 4 1 674 10892 1 1600 100 1 3 Defines the support information state for this system DellStateSettings Read only COO Support Information Is Outsourced Name Object ID Description Syntax Access cooSupportInformationIsOutsourced 1 3 6 1 4 1 674 10892 1 1600 100 1 4 Specifies whether the support for this system is outsourced or not DellBoolean Read write Cost of Ownership Group 455 COO Support Information Type Name cooSupportInformationType Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 5 Description Defines the type of component system or network problem that occurred Syntax DellUns
46. 1 Description Defines the index one based of the associated chassis Syntax DellObjectRange Access Read only 174 Power Group Power Usage Index Name Object ID Description Syntax Access powerUsageIndex 1 3 6 1 4 1 674 10892 1 600 60 1 2 Defines the index one based of the power usage information DellObjectRange Read only Power Usage State Capabilities Name Object ID Description Syntax Access powerUsageStateCapabilities 1 3 6 1 4 1 674 10892 1 600 60 1 3 Defines the state capabilities of the power usage information DellStateCapabilities Read only Power Usage State Settings Name Object ID Description Syntax Access powerUsageStateSettings 1 3 6 1 4 1 674 10892 1 600 60 1 4 Defines the state settings of the power usage information DellStateSettings Read write Power Usage Status Name Object ID Description Syntax Access powerUsageStatus 1 3 6 1 4 1 674 10892 1 600 60 1 5 Defines the status of the power usage information DellStatus Read only Power Group 175 Power Usage Entity Name Name Object ID Description Syntax Access powerUsageEntityName 1 3 6 1 4 1 674 10892 1 600 60 1 6 Defines the name of the entity associated with this power usage information DellString Read only Power Usage Cumulative Wattage Name Object ID Description Syntax Access powerUsageCumulativeWattage 1 3 6 1 4 1 674 10892 1 600 60 1 7 Defines the
47. 1 1600 10 1 25 Description Defines the name of the person who can sign the authorization for service Syntax DellCostofOwnershipString Access Read write COO Outsourcing Provider Fee Name Name cooOutsourcingProviderFeeName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 26 Description Defines any additional outsourcing charge for service Syntax DellCostofOwnershipString Access Read write COO Outsourcing Provider Service Level Name Name cooOut sourcingProviderServiceLevelNam Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 27 Description Defines the service level agreement for the system Syntax DellCostofOwnershipString Access Read write 434 Cost of Ownership Group COO Insurance Company Name Name cooInsuranceCompanyName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 28 Description Defines the name of the company that insures this system Syntax DellCostofOwnershipString Access Read write COO Box Asset Tag Name Name cooBoxAssetTagName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 29 Description Defines the name of the asset tag Syntax DellCostofOwnershipString Access Read write COO Box System Name Name cooBoxSystemName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 30 Description Defines the name of the system Syntax DellCostofOwnershipString Access Read write COO Box Central Processing Unit CPU Serial Number Name Name cooBoxCPUSerialNumberName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 31 Description Defi
48. 1 600 60 1 16 Description Defines the maximum potential power in Watts of the system This is the maximum power the system can consume based on the current hardware configuration Syntax DellUnsigned32BitRange Access Read only Power Usage Power Cap Capabilities Name powerUsagePowerCapCapabilities Object ID 1 3 6 1 4 1 674 10892 1 600 60 1 17 Description Defines the system power cap capabilities Syntax DellPowerCapCapabilities Access Read only Power Group 179 Power Usage Power Cap Setting Name Object ID Description Syntax Access powerUsagePowerCapSetting 1 3 6 1 4 1 674 10892 1 600 60 1 18 Defines the system power cap setting DellPowerCapSetting Read only Power Usage Power Cap Value Name Object ID Description Syntax Access powerUsagePowerCapValue 1 3 6 1 4 1 674 10892 1 600 60 1 19 Defines the system power cap value in Watts DellUnsigned32BitRange Read only Power Usage Instantaneous Headroom Name Object ID Description Syntax Access powerUsagelInstantaneousHeadroom 1 3 6 1 4 1 674 10892 1 600 60 1 20 Defines the system instantaneous headroom in Watts This is the theoretical maximum power drawn by the power supply minus instantaneous power draw DellUnsigned32BitRange Read only Power Usage Peak Headroom Name Object ID Description Syntax powerUsagePeakHeadroom 1 3 6 1 4 1 674 10892 1 600 60 1 21 Defines the system peak headroom in Watts This
49. 1 674 10892 1 1400 20 1 Description Defines the SCSI Control Table entry Syntax SCSIControlTableEntry Access Not accessible Index sCSIControlchassisIndex sCSIControlIndex SCSI Control Chassis Index Name sCSIControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only SCSI Control Index Name sCSIControlIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 2 Description Defines the index one based of the SCSI controller in this chassis Syntax DellObjectRange Access Read only 394 BIOS Setup Control Group SCSI Control Capabilities Name sCSIControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 3 Description Defines the capabilities of the SCSI controller Syntax DellStateCapabilities Access Read only SCSI Control Settings Name sCSIControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 4 Description Defines the state of the SCSI controller Syntax DellStateSettings Access Read only SCSI Control Status Name sCSIControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 5 Description Defines the status of the SCSI controller Syntax DellStatus Access Read only SCSI Control Name Name sCSIControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 6 Description Defines the setup BIOS name of the SCSI controller Syntax DellString Access Read only BIOS Setup Control Group 395 Parallel Port
50. 1 674 10892 1 1600 40 1 2 Description Defines the index of the warranty for this system Syntax DellObjectRange Access Read only 442 Cost of Ownership Group COO Warranty State Name cooWarrantyState Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 3 Description Defines the state of the warranty for this system Syntax DellStateSettings Access Read only COO Warranty Duration Name cooWarrantyDuration Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 4 Description Defines the duration of the warranty Syntax DellUnsigned32BitRange Access Read write COO Warranty Duration Type Name Object ID Description Syntax Access cooWarrantyDurationType 1 3 6 1 4 1 674 10892 1 1600 40 1 5 Defines the warranty duration type for the system DellCOODayMonthDurationType Read write COO Warranty End Date Name Name Object ID Description Syntax Access cooWarrantyEndDateName 1 3 6 1 4 1 674 10892 1 1600 40 1 6 Defines the warranty end date for this system DellDateName Read write Cost of Ownership Group 443 COO Warranty Cost Name cooWarrantyCost Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 7 Description Defines the cost of the warranty for this system Syntax DellUnsigned32BitRange Access Read write COO Lease Information Table The COO lease information MIB objects enable you to track information about your lessor lease duration and lease type for each system Name cooLeaseInformationTable Object ID 1 3
51. 10892 1 1000 80 1 5 Description Defines the status of the serial port Syntax DellStatus Access Read only Serial Port Security State Name serialPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 6 Description Defines the security settings of the serial port Syntax DellPortSecurityState Access Read only Serial Port Connector Type Name serialPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 7 Description Defines connector type of the serial port Syntax DellSerialPortConnectorType Access Read only Serial Port Name Name serialPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 8 Description Defines the name of the serial port Syntax DellString Access Read only 248 Port Group Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 9 Description Defines the maximum speed the serial interface can support in bits per second bps Syntax DellUnsigned32BitRange Access Read only Serial Port Capabilities Unique Name serialPortCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 10 Description Defines additional capabilities of the serial port Syntax DellSerialPortCapabilitiesUnique Access Read only Serial Port Base 1 0 Address Name serialPortBaselOAddress Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 11 Description Defines the base I O address of the serial port Syntax DellUnsigned64BitRange Access Read only Serial Port IRQ
52. 10892 1 1700 10 1 32 Description Defines the IP address for the gateway currently being used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read only 466 Remote Access Group Remote Access NIC Current Information From Dynamic Host Configuration Protocol DHCP Name remoteAccessNICCurrent InfoFromDHCP Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware Syntax DellBoolean Access Read only Remote Access Remote Connect URL Name remoteAccessRemoteConnectURL Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 34 Description Defines the URL for launching the Remote Access Remote Connect Interface Syntax DisplayString SIZE 0 63 Access Mandatory DRAC Ill On systems with DRAC III the Remote Access Group includes the following MIB tables Remote Access Table Remote User Administration Table Remote SNMP Trap Table Remote Dial Up Table Remote User Dial In Configuration Table Remote Dial Out Table Remote Access Group 467 Remote Access Table The following MIB object sets up the Remote Access Table Name remoteAccessTabl Object ID 1 3 6 1 4 1 674 10892 1 1700 10 Description Defines the Remote Access Table Syntax SEQUENCE OF RemoteAccessTableEntry Access Not accessible Remote Access Table Entry Name rem
53. 10893 1 20 130 7 1 17 Indicates the revision number of the fan in the enclosure DisplayString Read only Storage Management Group Fan Connection Table This table describes the connection between each fan on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table The following object sets up the Fan Connection Table Name Object ID Description Syntax Access fanConnectionTable fanConnection Table Defines the fan connection table SEQUENCE OF FanConnectionEntry Not accessible Fan Connection Entry Name Object ID Description Syntax Access Index fanConnectionEntry 1 3 6 1 4 1 674 10893 1 20 130 8 1 Defines the fan connection table entry FanConnectionEntry Not accessible fanConnectionNumber Fan Connection Number Name Object ID Description Syntax Access fanConnectionNumber 1 3 6 1 4 1 674 10893 1 20 130 8 1 1 Identifies the instance number of the fan connection entry Integer Read only Storage Management Group 609 Fan Connection Fan Name Name fanConnectionFanName Object ID 1 3 6 1 4 1 674 10893 1 20 130 8 1 2 Description Identifies the name of the fan in this connection as represented in Storage Management Syntax DisplayString Access Read only Fan Connection Fan Number Name fanConnectionFanNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 8 1 3 Description Identifies the instance numbe
54. 130 1 1 16 Identifies the size of memory on the controller that is less than a megabyte This combined with the controllerMemorySizeInMB will be the total size of the memory This attribute is only supported on Adaptec controllers Integer Read only Controller Drive Channel Count Name Object ID Description Syntax Access controllerDriveChannelCount 1 3 6 1 4 1 674 10893 1 20 130 1 1 17 This entry is obsolete Fibre channel is not supported in Storage Management Integer Read only Controller Fault Tolerant Name Object ID Description Syntax Access controllerFaultTolerant 1 3 6 1 4 1 674 10893 1 20 130 1 1 18 This entry is obsolete Fibre channel is not supported in Storage Management Integer Read only Storage Management Group __ 559 Controller CO Port 0 World Wide Name Name controllerC0OPort OWWN Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 19 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller CO Port 0 Name Name controllerCO0Port0Name Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 20 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller CO Port 0 ID Name controllerCOPort0ID Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 21 Description This entry is obsolete Fibre channel is not supported in Storage
55. 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDAth1lonxXP 182 The processor family is AMD Athlon XP deviceFamilyIsAMDAthlonMP 183 The processor family is AMD Athlon MP deviceFamilyIsAMDDuron 184 he processor family is AMD Duron deviceFamilyIsIntelPentiumM 185 he processor family is Intel Pentium M deviceFamilyIsIntelCeleronD 186 deviceFamilyIsIntelPentiumD 187 he processor family is Intel Pentium D T T The processor family is Intel Celeron D T T deviceFamilyIsIntelPentiumExtr The processor family is Intel Pentium eme 188 Processor Extreme Edition deviceFamilyIsIntelCoreSolo The processor family is Intel Core Solo 189 processor deviceFamilyIsIntelCore2 190 The processor family is Intel Core 2 processor deviceFamilyIsIntelCore2Duo The processor family is Intel Core 2 Duo 191 processor deviceFamilyIsIntelCore2Solo 1_ The processor family is Intel Core2 Solo 92 processor deviceFamilyIsIntelCore2Extrem The processor family is Intel Core2 E e 193 xtreme processor deviceFamilyIsIntelCore2Quad 1_ The processor family is Intel Core2 94 Quad processor deviceFamilyIsIntelCore2Extrem The processor family is Intel Core2 E eMobile 195 xtreme mobile processor deviceFamilyIsIntelCore2DuoMob The processor family is Intel Core2 Duo ile 196 mobile processor
56. 2 The power supply s state is disabled offline a binary 0 value or enabled online a binary 1 value not Ready 4 The power supply s state is not ready fanFailure 8 The power supply fan has failed 184 Power Group Table 8 2 Power Supply State Settings Unique continued Variable Name De 1 1PowerSupplyStateSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value onlineAndFanFailure 10 The power supply is online and indicating that its fan is not working powerSupplyIsON 16 The power supply is indicating that it is on powerSupplyIsoOk 32 The power supply is indicating that it is OK acSwitchIsON 64 The power supply is indicating that the AC power switch is on onlineandAcSwitchIsON 66 The power supply is online and indicating that the AC power supply switch capability is activated acPowerIsON 128 The power supply is indicating that the AC power is on onlineAndAcPowerIsON 130 The power supply is online and indicating that the AC power is on onlineAndPredictiveFail ure 210 The power supply is online and indicating that it has a problem acPowerAndSwitchAreOn PowerSupplyIsOnIsoOkAnd Online 242 The power supply is online and OK Table 8 3 Power Supply Type Definitions Variable Name De 1 1PowerSupplyType Data Type Integer Possible Data Values Meaning of Data Value powerSu
57. 20 1 6 Description Defines the interface type for this system resource owner Syntax DellResourceOwnerInterfaceType See Table 7 2 Access Read only System Resource Map Index Reference Name systemResourceMapIndexReferenc Object ID 1 3 6 1 4 1 674 10892 1 500 20 1 7 Description Defines the index to the associated system resource map in this chassis Syntax DellObjectRange Access Read only System Resource Group 131 System Resource Owner Description Name Name systemResourceOwnerDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 500 20 1 8 Description Defines the description name of the system resource owner Syntax DellString Access Read only System Resource Owner Interface Instance Name systemResourceOwnerInterfaceInstance Object ID 1 3 6 1 4 1 674 10892 1 500 20 1 9 Description Defines the associated system resource owner interface instance in this chassis Syntax DellObjectRange Access Read only System Resource Input Output 1 0 Port Table Name systemResourcelOPortTable Object ID 1 3 6 1 4 1 674 10892 1 500 30 Description Defines the System Resource I O Port Table Syntax SEQUENCE OF SystemResourcelOPortTableEntry Access Not accessible System Resource 1 0 Port Table Entry Name systemResourcelOPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 Description Defines the System Resource I O Port Table entry Syntax SystemResourcelOPortTableEntry Access Not accessible Index systemRes
58. 200 1 200 1 200 1 200 1 200 1 200 1 200 1 6300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 We 2a ed L251 TriZ L 27 1 28 51 L 29 1 1 30 1 Sed eA Tied L 42 1 1 43 1 O OE On On On Oe Oe Oe Oe Oe Oe Oe L 10 1 11 1 Tl Zee SNMP Sample Output 02 03 03 1 0 2 3 0 23 Main System Dell Inc PowerEdge ASSETTAG 1234567 254 751 Is 1 1 Eer Gs Live 20050513100052 W U W 3 1 53 the Less the w the IRS 752 OQ Ww Wo Wo Wo Wo Wo Wo A Wo o Wo A WwW Ww 6 6 1 val Gisla val H aD Oo 1 4 lue oY OF OY oO OY OF OY OY OY OF OY OY OY OF OD 4 4 ue ue 4 1 4 1 L 4 1 PLTA 1 674 4 1 t s1074 674 SE SEE E 120050513095213 674 674 674 OTA 674 674 674 674 1 674 674 674 674 674 674 674 674 674 ETA 10892 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 1 300 1 000000 360 L 300 1 000000 360 L 300 1 SNMP Sample Output 10892 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300 1 300
59. 3 6 1 4 1 674 10892 1 300 10 1 35 Description Defines the capabilities of the watchdog expiry timer object Syntax DellWatchDogTimerCapabilities See Table 5 13 Access Read only 80 Chassis Information Group Chassis Watchdog Control Expiry Time Name Object ID Description Syntax Access chassiswatchDogControlExpiryTime 1 3 6 1 4 1 674 10892 1 300 10 1 36 Defines the current reading and allows setting of the nonrecoverable watchdog expiry timer object DellUnsigned16BitRange Read write Chassis Allow Set Commands From SNMP Name Object ID Description Syntax Access chassisallowSETCommands fromSNMP 1 3 6 1 4 1 674 10892 1 300 10 1 37 Specifies whether Simple Network Management Protocol SNMP Set type commands are allowed by Server Administrator This attribute does not reflect whether SNMP Set type commands are allowed by the SNMP master agent DellBoolean Read only Chassis Power Button Control Capabilities Unique Name Object ID Description Syntax Access chassisPowerButtonControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 300 10 1 38 Defines the capabilities of the power button control function DellPowerButtonControlCapabilities See Table 5 16 Read only Chassis Information Group 81 Chassis Power Button Control Settings Unique Name chassisPowerButtonControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 39 Description Defines the current reading and all
60. 300 70 1 2 Defines the index of the intrusion objects in this subgroup DellObjectRange Read only Intrusion State Capabilities Name Object ID Description Syntax Access intrusionStateCapabilities 1 3 6 1 4 1 674 10892 1 300 70 1 3 Defines the capabilities of the intrusion object DellStateCapabilities Read only Intrusion State Settings Name Object ID Description Syntax Access intrusionStateSettings 1 3 6 1 4 1 674 10892 1 300 70 1 4 Defines the settings of the intrusion object DellStateSettings Read write Intrusion Status Name Object ID Description Syntax Access intrusionStatus 1 3 6 1 4 1 674 10892 1 300 70 1 5 Defines the status of the intrusion object DellStatus Read only Chassis Information Group 101 Intrusion Reading Name intrusionReading Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 6 Description Defines the reading of the intrusion object Syntax DellIntrusionReading Access Read only Intrusion Type Name intrusionType Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 7 Description Defines the type of the intrusion object Syntax DellIntrusionType Access Read only Intrusion Location Name Name intrusionLocationName Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 8 Description Defines the location name of the intrusion object in this subgroup Syntax DellString Access Read only Baseboard Table This table lists objects that define the baseboard of a system Name baseBoa
61. 5 in 360 RPM is supported Bit 22Int 13h 5 25 in 360 KB Floppy Services are supported Bit 23Int 13h 5 25 in 1 2MB Floppy Services are supported Bit 24Int 13h 3 5 in 720 KB Floppy Services are supported Bit 25Int 13h 3 5 in 2 88 MB Floppy Services are supported Bit 26Int 5h Print Screen Service is supported Bit 27Int 9h 8042 Keyboard services are supported Bit 28Int 14h Serial Services are supported Bit 29Int 17h Printer Services are supported Bit 30Int 10h CGA Mono Video Services are supported Bit 3INEC PC 98 Bit 32 47Reserved Bit 48Built in NIC supports Magic Packet Bit 49System supports Wake on LAN Bit 50System supports chassis intrusion Bit 51 Built in NIC supports pattern matching Bit 52System BIOS supports a 7 character service tag Bit 53 63 Reserved DellUnsigned64BitRange Chassis Information Group 95 System BIOS Characteristics Ext 1 Name Object ID Description Syntax Access systemBIOSCharacteristicsExtl 1 3 6 1 4 1 674 10892 1 300 50 1 13 Defines additional characteristics of the system basic input output system BIOS This attribute is a bit field where a bit has the meaning defined below when set to one Bit Position Meaning if Set Bit OACPI supported Bit 1USB Legacy is supported Bit 2AGP is supported Bit 3120 boot is supported Bit 4LS 120 boot is supported Bit 5ATAPI ZIP Drive boot is supported Bit 61394 boot is supported Bit 7Smart Battery supported Dell
62. 6 Voltage Probe Type continued Variable Name De11VoltageType Data Type Integer Possible Data Values Meaning of Data Value voltageProbeTypelIs3Point3Volt The voltage probe type is a 3 3 V probe 4 voltageProbeTypels5Volt 5 The voltage probe type is a 5 V probe voltageProbeTypeIsMinus5Volt The voltage probe type is a 5 V probe 6 voltageProbeTypels1l2Volt 7 The voltage probe type is a 12 V probe voltageProbeTypeIsMinus12Volt The voltage probe type is a 12 V probe 8 voltageProbeTypelsI10 9 The voltage probe type is an I O volt probe voltageProbeTypelsCore 10 The voltage probe type is a core volt probe voltageProbeTypelIsFLEA 11 The voltage probe type is a FLEA standby volt probe voltageProbeTypelIsBattery 12 The voltage probe type is a battery volt probe voltageProbeTypelIsTerminator The voltage probe type is a SCSI 13 termination volt probe voltageProbeTypelIs2Point5Volt The voltage probe type is a 2 5 V probe 14 voltageProbeTypeIsGTL 15 The voltage probe type is a ground termination logic GTL probe voltageProbeTypelIsDiscrete 16 The voltage probe type is a voltage probe with discrete reading Power Group Table 8 7 Voltage Probe Discrete Reading Variable Name De11VoltageDiscreteReading Data Type Integer Possible Data Values Meaning of Data Value voltageIsGo
63. 600 12 1 11 Defines the state reported by the power supply sensor and supplements the state and settings of the power supply DellPowerSupplySensorState See Table 8 4 Read only Power Supply Configuration Error Type Name Object ID Description Syntax Access powerSupplyConfigurationErrorType 1 3 6 1 4 1 674 10892 1 600 12 1 12 Defines the type of configuration error reported by the power supply sensor DellPowerSupplyConfigurationErrorType See Table 8 5 Read only Power Supply Power Monitor Capable Name Object ID Description Syntax Access powerSupplyPowerMonitorCapable 1 3 6 1 4 1 674 10892 1 600 12 1 13 Defines a boolean value that reports whether the power supply is capable of monitoring power consumption DellBoolean Read only Power Group 155 Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1 3 6 1 4 1 674 10892 1 600 12 1 14 Description Defines the rated input wattage of the power supply in tenths of Watts Syntax DellSigned32BitRange Access Read only Voltage Probe Table Name voltageProbeTable Object ID 1 3 6 1 4 1 674 10892 1 600 20 Description Defines the Voltage Probe Table Syntax VoltageProbeTableEntry Access Not accessible Voltage Probe Table Entry Name Object ID Description Syntax Access Index voltageProbeTableEntry 1 3 6 1 4 1 674 10892 1 600 20 1 Defines the Voltage Probe Table entry VoltageProbe TableEntr
64. 674 10892 1 1100 20 1 8 Description Defines the name of the keyboard layout Syntax DellString Access Read only 264 Device Group Processor Device Table Name Object ID Description Syntax Access processorDeviceTabl 1 3 6 1 4 1 674 10892 1 1100 30 Defines the Processor Device Table SEQUENCE OF ProcessorDeviceTableEntry Not accessible Processor Device Table Entry Name Object ID Description Syntax Access Index processorDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 30 1 Defines the Processor Device Table entry ProcessorDeviceTableEntry Not accessible processorDevicechassisIndex processorDeviceIndex Processor Device Chassis Index Name Object ID Description Syntax Access processorDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 30 1 1 Defines the index one based of this chassis DellObjectRange Read only Processor Device Index Name Object ID Description Syntax Access processorDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 30 1 2 Defines the index of the processor device in this chassis DellObjectRange Read only Device Group 265 Processor Device State Capabilities Name Object ID Description Syntax Access processorDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 30 1 3 Defines the capabilities of the processor device DellStateCapabilities Read only Processor Device State Settings Name Object ID Description Syntax Access
65. 674 10892 1 1300 30 1 2 Defines the index one based of the physical memory configuration DellObjectRange Read only Physical Memory Configuration State Capabilities Name Object ID Description Syntax Access physicalMemoryConfigStateCapabilities 1 3 6 1 4 1 674 10892 1 1300 30 1 3 Defines the state capabilities of the physical memory configuration DellPhysicalMemoryContigStateCapabilities Read only Physical Memory Configuration State Settings Name Object ID Description Syntax Access 368 physicalMemoryConfigStateSettings 1 3 6 1 4 1 674 10892 1 1300 30 1 4 Defines the state settings of the physical memory configuration DellPhysicalMemoryConfigStateSettings Read write Memory Group Physical Memory Configuration Status Name Object ID Description Syntax Access physicalMemoryConfigStatus 1 3 6 1 4 1 674 10892 1 1300 30 1 5 Defines the status of the physical memory configuration DellStatus Read only Physical Memory Configuration Redundant Capabilities Name Object ID Description Syntax Access physicalMemoryConfigRedundantCapabilities 1 3 6 1 4 1 674 10892 1 1300 30 1 6 Defines the redundant capabilities of the physical memory DellPhysicalMemoryConfigRedundantCapabilities Read only Physical Memory Configuration Redundant Settings Name Object ID Description Syntax Access physicalMemoryConfigRedundantSettings 1 3 6 1 4 1 674 10892 1 1300 30 1 7 Defines the redun
66. 674 10892 2 3 3 6 Description Defines the timestamp of the most recent fan health status change Syntax TimeTicks Access Read only 678 Dell RAC Out of Band Group DRsBladeChangeTime Name DRsBladeChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 7 Description Defines the timestamp of the most recent blade health status change Syntax TimeTicks Access Read only DRsTempChangeTime Name DRsTempChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 8 Description Defines the timestamp of the most recent temperature sensor health status change Syntax TimeTicks Access Read only DRsCMCChangeTime Name DRsCMCChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 9 Description Syntax Access Defines the timestamp of the most recent CMC health status change TimeTicks Read only Dell RAC Out of Band Group 679 Chassis Power The following MIB tables provide information on the chassis management controller table entry DRsCMC Power Table Name DRsCMCPowerTable Object ID 1 3 6 1 4 1 674 10892 2 4 1 Description Defines the CMC power table Syntax SEQUENCE OF DrsCMCPowerTableEntry Access Not accessible DRsCMC Power Table Entry Name DRsCMCPowerTableEntry Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 Description Defines the CMC power table entry Syntax DrsCMCPowerTableEntry Access Not accessible DRsCMC PSUTable Name DrsCMCPSUTable Object ID 1 3 6 1 4 1 674 10892 2 4 2 Description Defines the CMC PSU ta
67. Battery Charge Count Name batteryChargeCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 7 Description The number of charges that have been applied to the battery Syntax Integer Access Read only Battery Max Charge Count Name batteryMaxChargeCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 8 Description The maximum number of charges that can be applied to the battery Syntax Integer Access Read only Battery Nexus ID Name batteryNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 9 Description Durable unique ID for this EMM Syntax DisplayString Access Read only 636 Storage Management Group Battery Predicted Capacity Name batteryPredictedCapacity Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 10 Description Displays the battery s ability to be charged Possible values 1 Failed The battery cannot be charged and needs to be replaced 2 Ready The battery can be charged to full capacity 4 Unknown The battery is completing a Learn cycle The charge capacity of the battery cannot be determined until the Learn cycle is complete Syntax Integer Access Read only Battery Next Learn Time Name batteryNextLearnTim Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 11 Description Indicates the time in hours the next learn cycle must be executed Syntax Integer Access Read only Storage Management Group 637 Battery Learn State Name batteryLearnState Object ID 1 3 6 1 4 1 674 10
68. Card Unit Status Combined Name Object ID Description Syntax Access systemStateSDCardUnitStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 54 Defines the combined status of all SD Card units of this chassis DellStatus Read only System State SD Card Unit Status List Name Object ID Description Syntax Access systemStateSDCardUnitStatusList 1 3 6 1 4 1 674 10892 1 200 10 1 55 Lists the status of each SD Card unit of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card unit The first byte returned represents the status of the first SD Card unit and so on The bytes have the same definition type as DellStatus OCTET STRING SIZE 1 128 Read only System State SD Card Device Status Combined Name Object ID Description systemStateSDCardDeviceStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 56 Defines the combined status of all SD Card devices of this chassis System State Group 69 Name systemStateSDCardDeviceStatusCombined Syntax DellStatus Access Read only System State SD Card Device Status List Name systemStateSDCardDeviceStatusList Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 57 Description Lists the status of each SD Card device of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card device The first byte returned represents the
69. Checking and Correcting ECC Type Name physicalMemoryArrayECCType Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 7 Description Defines the ECC type used by the physical memory array Syntax DellPhysicalMemoryArrayECCType See Table 15 2 Access Read only Physical Memory Array Location Name physicalMemoryArrayLocation Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 8 Description Defines the location of the physical memory array Syntax DellPhysicalMemoryArrayLocation See Table 15 1 Access Read only Physical Memory Array Maximum Size Name physicalMemoryArrayMaximumSize Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 9 Description Defines the size in KB of the physical memory array Syntax DellUnsigned32BitRange Access Read only Physical Memory Array Total Number Sockets Name physicalMemoryArrayTotalNumberSockets Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 10 Description Defines the total number of memory sockets available for the physical memory array Syntax DellUnsigned32BitRange Access Read only 362 Memory Group Physical Memory Array In Use Number Sockets Name Object ID Description Syntax Access physicalMemoryArrayInUseNumberSockets 1 3 6 1 4 1 674 10892 1 1300 10 1 11 Defines the total number of memory sockets in use by the physical memory array DellUnsigned32BitRange Read only Physical Memory Array ECC Error Nonrecoverable Threshold Name Object ID Description Syntax Access
70. Control Table Name parallelPortControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 30 Description Defines the Parallel Port Control Table Syntax ParallelPortControlTableEntry Access Not accessible Parallel Port Control Table Entry Name parallelPortControlTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1400 30 1 Description Defines the Parallel Port Control Table entry Syntax ParallelPortControl TableEntry Access Not accessible Index parallel PortControlchassisIndex parallelPortControlIndex Parallel Port Control Chassis Index Name parallelPortControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 30 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Parallel Port Control Index Name parallelPortControlIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 30 1 2 Description Defines the index one based of the parallel port in this chassis Syntax DellObjectRange Access Read only 396 BIOS Setup Control Group Parallel Port Control Capabilities Unique Name Object ID Description Syntax Access parallelPortControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1400 30 1 3 Defines the capabilities of the parallel port DellParallelPortControlCapabilitiesUnique See Table 16 12 Read only Parallel Port Control Settings Unique Name Object ID Description Syntax Access parallelPortControlSettingsUnique 1 3 6 1 4 1 674 10892 1 1400 30 1 4 Defines the s
71. Defines the index for the associated system cooling unit in this chassis DellObjectRange Read only Cooling Device Subtype Name Object ID Description Syntax Access 204 coolingDeviceSubType 1 3 6 1 4 1 674 10892 1 700 12 1 16 Defines the cooling device subtype DellCoolingDeviceSubType See Table 9 2 Read only Thermal Group Cooling Device Probe Capabilities Name Object ID Description Syntax Access coolingDeviceProbeCapabilities 1 3 6 1 4 1 674 10892 1 700 12 1 17 Defines the probe capabilities of the cooling device DellProbeCapabilities Read only Cooling Device Discrete Reading Name Object ID Description Syntax Access coolingDeviceDiscreteReading 1 3 6 1 4 1 674 10892 1 700 12 1 18 Defines the reading for a voltage probe of type coolingDeviceSubTypelsDiscrete When the value for coolingDeviceSubType is other than coolingDeviceSubTypelsDiscrete a value is not returned for this attribute When the value for coolingDeviceSubType is coolingDeviceSubTypelsDiscrete the value returned for this attribute is the discrete reading for the cooling device DellCoolingDeviceDiscreteReading See Table 9 3 Read only Temperature Probe Table Name Object ID Description Syntax Access temperatureProbeTabl 1 3 6 1 4 1 674 10892 1 700 20 Defines the Temperature Probe Table TemperatureProbeTableEntry Not accessible Thermal Group 205 Temperature Probe Table E
72. Defines the status of the serial port Syntax DellStatus Access Read only Serial Port Control Name Name serialPortControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 6 Description Defines the setup BIOS name of the serial port Syntax DellString Access Read only USB Control Table These objects enable you to track the attributes of your Universal Serial Bus USB Name usbControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 50 Description Defines the USB Table Syntax UsbControl TableEntry Access Not accessible USB Control Table Entry Name usbControlTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 Description Defines the USB Table entry 400 BIOS Setup Control Group Name Syntax Access Index usbControlTableEntry UsbControl TableEntry Not accessible usbControlchassisIndex usbControlIndex USB Control Chassis Index Name usbControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 1 Description Defines index one based of this chassis Syntax DellObjectRange Access Read only USB Control Index Name usbControlIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 2 Description Defines the index one based of the USB in this chassis Syntax DellObjectRange Access Read only USB Control Capabilities Name Object ID Description usbControlCapabilities 1 3 6 1 4 1 674 10892 1 1400 50 1 3 Defines the capabilities of the USB Syntax DellStateCapabilities Access Read only
73. Description Syntax Access applicationDeviceIndex 1 3 6 1 4 1 674 10899 1 6 1 2 Defines a cross index to the device table for the application Unsigned 16BitRange Read only Change Management Group _ 661 Application Component Type Name applicationComponentType Object ID 1 3 6 1 4 1 674 10899 1 6 1 3 Description Identifies the type of application reported Syntax DisplayString Access Read only Application Version Name applicationVersion Object ID 1 3 6 1 4 1 674 10899 1 6 1 4 Description Identifies the version of the application Syntax DisplayString Access Read only Application Display String Name applicationDisplayString Object ID 1 3 6 1 4 1 674 10899 1 6 1 5 Description A user visible display string that describes the application Syntax DisplayString Access Read only Application Sub Component ID Name applicationSubComponentID Object ID 1 3 6 1 4 1 674 10899 1 6 1 6 Description The sub component ID for the application This is usually valid on ESM device reporting Syntax DisplayString Access Read only 662 Change Management Group Operating System Group The Operating System Group provides status and identifying information about a system s operating system Identifying information includes the name version and service pack of the installed operating system The following objects describe the fields for Operating System Group Operating System Vendor Name operatingSystemVendor
74. Description Defines the manufacturer of the FRU Syntax DisplayString SIZE 0 64 Access Read only FRU Serial Number Name Name fruSerialNumberName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 7 Description Defines the serial number of the FRU Syntax DisplayString SIZE 0 64 Access Read only FRU Part Number Name Name fruPartNumberName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 8 Description Defines the part number of the FRU Syntax DisplayString SIZE 0 64 Access Read only Field Replaceable Unit Group 539 FRU Revision Name Name fruRevisionName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 9 Description Defines the revision of the FRU Syntax DisplayString SIZE 0 64 Access Read only FRU Manufacturing Date Name Name fruManufacturingDateName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 10 Description Defines the manufacturing date of the FRU Syntax DellDateName Access Read only FRU Asset Tag Name Name fruAssetTagName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 11 Description Defines the asset tag of the FRU Syntax DisplayString SIZE 0 64 Access Read only 540 Field Replaceable Unit Group FRU Group Variable Values This section includes definitions for server administrator specific variable values Table 22 1 FRU Information State Variable Name De 11 FRUInformationState Data Type Integer Possible Data Values Meaning of Data Value ok 1 FRU information i
75. Description Indicates the suggested timeout value in milliseconds for how long the SNMP getter should wait while attempting to poll the SNMP agent Syntax Integer Access Read only Storage Management Group 547 Agent Modifiers Name agentModifiers Object ID 1 3 6 1 4 1 674 10893 1 20 110 5 Description Identifies the agent functional modifiers When set the modifier is active Bit definitions Bit 3 agent in debug mode All other bits are product specific Syntax Integer Access Read only Agent Refresh Rate Name agentRefreshRat Object ID 1 3 6 1 4 1 674 10893 1 20 110 6 Description Identifies the rate given in seconds at which the cached data for SNMP is refreshed The default value is 300 seconds or 5 minutes Syntax Integer Access Read only Agent Hostname Name agentHostname Object ID 1 3 6 1 4 1 674 10893 1 20 110 7 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only 548 Storage Management Group Agent IP Address Name agentIPAddress Object ID 1 3 6 1 4 1 674 10893 1 20 110 8 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only Agent Software Status Name agent SoftwareStatus Object ID 1 3 6 1 4 1 674 10893 1 20 110 9 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only Agent SNMP Version Name agentSnmpVersion Object ID 1 3 6 1 4 1 674 10893 1 2
76. Integer Access Read only Virtual Disk Current Stripe Size in Megabytes Name virtualDiskCurStripeSizeInMB Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 14 Description Identifies the stripe size of this virtual disk in megabytes If this size is 0 it is smaller than a megabyte Syntax Integer Access Read only Storage Management Group 647 Virtual Disk Current Stripe Size in Bytes Name virtualDiskCurStripeSizeInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 15 Description Identifies the portion of the stripe size in bytes that is smaller than a megabyte This size plus the virtualDiskCurStripeSizeInMB is the total stripe size on the virtual disk Syntax Integer Access Read only Virtual Disk Channel Name virtualDiskChannel Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 16 Description This entry is obsolete This property is not supported by virtual disks managed under Storage Management Syntax Integer Access Read only Virtual Disk Target ID Name virtualDiskTargetID Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 17 Description Unique ID for the virtual disk Syntax Integer Access Read only Virtual Disk LUN ID Name virtualDiskLunID Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 18 Description This entry is obsolete This property is not supported by virtual disks managed under Storage Management Syntax Integer Access Read only 648 Storage Management Group Virtual Disk Roll Up Status N
77. LRA is set to all LRA settings combinations 426 Local Response Agent Group Cost of Ownership Group The Cost of Ownership COO Group provides a full set of cost tracking objects including fields for the computer s manufacturer insurer lessor warranty user trouble tickets and many others You can use these management information base MIB objects to obtain accurate and complete measurements of the cost of each computer asset in your organization Cost of Ownership Group Tables The Cost of Ownership Group defines objects in the following MIB tables e Cost of Ownership Table e COO Service Contract Table e COO Cost Event Log Table e COO Warranty Table e COO Lease Information Table e COO Schedule Number Table e COO Options Table e COO Maintenance Table COO Repair Table e COO Support Information Table e COO Trouble Ticket Table Cost of Ownership Table The following MIB object sets up the Cost of Ownership Table Name cooTable Object ID 1 3 6 1 4 1 674 10892 1 1600 10 Description Defines the Cost of Ownership Table Syntax SEQUENCE OF CooTableEntry Access Not accessible Cost of Ownership Group 427 Cost of Ownership Table Entry Name cooTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 Description Defines the Cost of Ownership Table entry Syntax CooTableEntry Access Not accessible Index coochassisIndex COO Chassis Index Name coochassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 1
78. Level Name serialPortIRQLevel Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 12 Description Defines the IRQ of the serial port Syntax DellUnsigned8BitRange Access Read only PortGroup 249 Universal Serial Bus USB Port Table Name Object ID Description Syntax Access uSBPortTable 1 3 6 1 4 1 674 10892 1 1000 90 Defines the USB Port Table IntegerUSBPortTableEntry Not accessible USB Port Table Entry Name uSBPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 Description Defines the USB Port Table entry Syntax USBPort TableEntry Access Not accessible Index uSBPortchassisIndex uSBPortIndex USB Port Chassis Index Name uSBPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only USB Port Index Name uSBPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 2 Description Defines the index of the USB ports in this chassis Syntax DellObjectRange Access Read only 250 Port Group USB Port State Capabilities Name Object ID Description Syntax Access uSBPortStateCapabilities 1 3 6 1 4 1 674 10892 1 1000 90 1 3 Defines the capabilities of the USB port DellStateCapabilities Read only USB Port State Settings Name Object ID Description Syntax Access USB Port Status Name Object ID Description Syntax Access uSBPortStateSettings 1 3 6 1 4 1 674 10892 1 1000 90 1 4
79. Name Object ID Description Syntax Access bmcLANInterfaceChannelNumber 1 3 6 1 4 1 674 10892 1 1900 30 1 7 Defines the BMC channel number of the BMC LAN interface DellUnsigned8BitRange Read only BMC LAN Interface IP Address Source Name Object ID Description Syntax Access bmcLANInterfaceIPAddressSource 1 3 6 1 4 1 674 10892 1 1900 30 1 8 Defines the source type of the IP address of the BMC LAN interface DelIBMCLANIPAddressSourceType Read only BMC LAN Interface IP Address Name Object ID Description Syntax Access bmcLANInterfacelIPAddress 1 3 6 1 4 1 674 10892 1 1900 30 1 9 Defines the IP address of the BMC LAN interface IpAddress Read only Baseboard Management Controller Group 531 BMC LAN Interface Subnet Mask Address Name bmcLANInterfaceSubnetMaskAddress Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 10 Description Defines the subnet mask of the BMC LAN interface Syntax IpAddress Access Read only BMC LAN Interface Default Gateway Address Name bmcLANInterfaceDefaultGatewayAddress Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 11 Description Defines the IP address of the default gateway for the BMC LAN interface Syntax IpAddress Access Read only BMC LAN Interface MAC Address Name bmcLANInterfaceMACAddress Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 12 Description Defines the MAC address of the BMC LAN interface Syntax DellIMACAddress Access Read only BMC LAN Int
80. Name Object ID Description Syntax Access temperatureProbeProbeCapabilities 1 3 6 1 4 1 674 10892 1 700 20 1 15 Defines the probe capabilities of the temperature probe DellProbeCapabilities Read only Temperature Probe Discrete Reading Syntax Access 210 Name Object ID Description temperatureProbeDiscreteReading 1 3 6 1 4 1 674 10892 1 700 20 1 16 Defines the reading for a temperature probe of type temperatureProbeTypelsDiscrete When the value for temperatureProbeType is other than temperatureProbeTypelsDiscrete a value is not returned for this attribute When the value for temperatureProbe Type is temperatureProbeTypelsDiscrete the value returned for this attribute is the discrete reading for the probe Dell TemperatureDiscreteReading See Table 9 5 Read only Thermal Group Thermal Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 9 1 Cooling Device Type Variable Name De 1 1CoolingDeviceType Data Type Integer Possible Data Values Meaning of Data Value coolingDeviceTypelsOther 1 The cooling device type is not one of the following coolingDeviceTypelIsUnknown 2 The cooling device type is unknown not known or not monitored coolingDeviceTypelIsAFan 3 The cooling device type is a fan coolingDeviceTypelIsABlower 4 The cooling device type is
81. Object ID Description Syntax Access memoryDeviceMappedAddresschassisIndex 1 3 6 1 4 1 674 10892 1 1100 60 1 1 Defines the index one based of this chassis DellObjectRange Read only Device Group 289 Memory Device Mapped Address Index Name Object ID Description Syntax Access memoryDeviceMappedAddress Index 1 3 6 1 4 1 674 10892 1 1100 60 1 2 Defines the index one based of the memory device mapped address in this chassis DellObjectRange Read only Memory Device Mapped Address State Capabilities Name Object ID Description Syntax Access memoryDeviceMappedAddressStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 60 1 3 Defines the capabilities of the memory device mapped address DellStateCapabilities Read only Memory Device Mapped Address State Settings Name Object ID Description Syntax Access memoryDeviceMappedAddressStateSettings 1 3 6 1 4 1 674 10892 1 1100 60 1 4 Defines the state of the memory device mapped address DellStateSettings Read write Memory Device Mapped Address Status Name Object ID Description Syntax Access 290 memoryDeviceMappedAddressStatus 1 3 6 1 4 1 674 10892 1 1100 60 1 5 Defines the status of the memory device mapped address DellStatus Read only Device Group Memory Device Index Reference Name Object ID Description Syntax Access memoryDeviceIndexReferenc 1 3 6 1 4 1 674 10892 1 1100 60 1 6 D
82. Object ID Description Syntax Access cooDepreciationPercentage 1 3 6 1 4 1 674 10892 1 1600 10 1 37 Defines the percentage of depreciation for this system DellUnsigned32BitRange Read write COO Depreciation Method Name Name Object ID Description Syntax Access cooDepreciationMethodName 1 3 6 1 4 1 674 10892 1 1600 10 1 38 Defines the name of the depreciation method for this system DellCostofOwnershipString Read write COO Registration Is Registered Object ID Description Syntax Access cooRegistrationIsRegistered 1 3 6 1 4 1 674 10892 1 1600 10 1 39 Specifies whether this system is registered or not DellBoolean Read write Cost of Ownership Group 437 COO Service Contract Table The service contract table provides MIB objects that help you track the name vendor and type of service contract you have for your system Name cooServiceContractTable Object ID 1 3 6 1 4 1 674 10892 1 1600 20 Description Defines the COO Service Contract Table Syntax SEQUENCE OF CooServiceContractTableEntry Access Not accessible COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 Description Defines the COO Service Contract Table entry Syntax CooServiceContract TableEntry Access Not accessible Index cooServiceContractchassisIndex cooServiceContractIndex COO Service Contract Chassis Index Name cooServiceContractchassisIndex Object ID
83. Object ID 1 3 6 1 4 1 674 10899 2 1 Description Defines the vendor of the Operating System Syntax DisplayString Access Read only Operating System Major Version Name operatingSystemMajorVersion Object ID 1 3 6 1 4 1 674 10899 2 2 Description Defines the major version of the Operating System Syntax DisplayString Access Read only Operating System Minor Version Name operatingSystemMinorVersion Object ID 1 3 6 1 4 1 674 10899 2 3 Description Defines the minor version of the Operating System Syntax DisplayString Access Read only Change Management Group _ 663 Operating System Service Pack Major Version Name operatingSystemSPMajorVersion Object ID 1 3 6 1 4 1 674 10899 2 5 Description Defines the Operating System s Service Pack major version Syntax DisplayString Access Read only Operating System Service Pack Minor Version Name operatingSystemSPMinorVersion Object ID 1 3 6 1 4 1 674 10899 2 6 Description Defines the Operating System s Service Pack minor version Syntax DisplayString Access Read only Operating System Architecture Name operatingSystemArchitecture Object ID 1 3 6 1 4 1 674 10899 2 7 Description Defines the Operating System s architecture Syntax DisplayString Access Read only Inventory Collector Product Information The following objects describe the fields for the Inventory Collector The Inventory Collector product variables are scalar objects meaning that they are not related to o
84. Power Cord AC Power Switch Index Reference Name Object ID Description Syntax Access aCPowerCordaCPowerSwitchIndexReference 1 3 6 1 4 1 674 10892 1 600 42 1 6 Defines the index one based to the associated AC power switch for this AC power cord DellObjectRange Read only AC Power Cord Location Name Name Object ID Description Syntax Access aCPowerCordLocationName 1 3 6 1 4 1 674 10892 1 600 42 1 7 Defines the location name of this AC power cord DellString Read only Power Group 171 172 Battery Table Name Object ID Description Syntax Access Battery Table Entry Name Object ID Description Syntax Access Index batteryTable 1 3 6 1 4 1 674 10892 1 600 50 Defines the Battery Table SEQUENCE OF BatteryTableEntry Not accessible batteryTableEntry 1 3 6 1 4 1 674 10892 1 600 50 1 Defines the Battery Table Entry Battery TableEntry Not accessible batteryChassisIndex batteryIndex Battery Chassis Index Name Object ID Description Syntax Access Battery Index Name Object ID Description Syntax Access batteryChassisIndex 1 3 6 1 4 1 674 10892 1 600 50 1 1 Defines the index one based of the chassis that contains the battery DellObjectRange Read only batteryIndex 1 3 6 1 4 1 674 10892 1 600 50 1 2 Defines the index one based of the battery DellObjectRange Read only Power Group Battery State Capabilities Name batteryStateCapa
85. Read only Enclosure Nexus ID Name Object ID Description Syntax Access enclosureNexusID 1 3 6 1 4 1 674 10893 1 20 130 3 1 25 Durable unique ID for this enclosure Integer Read only Enclosure FirmWare Version Name Object ID Description Syntax Access enclosureFirmwareVersion 1 3 6 1 4 1 674 10893 1 20 130 3 1 26 The firmware version of the enclosure DisplayString Read only Storage Management Group 583 Enclosure SCSI Rate Name enclosureSCSIRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 27 Description Actual SCSI rate in the enclosure Syntax DisplayString Access Read only Enclosure Part Number Name enclosurePartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 28 Description The part number of the enclosure Syntax DisplayString Access Read only Enclosure Serial Number Name enclosureSerialNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 29 Description Serial number of the enclosure Syntax DisplayString Access Read only Enclosure SAS Address Name enclosureSASAddress Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 30 Description The specified SAS address if this is a SAS enclosure Syntax DisplayString Access Read only 584 Storage Management Group Array Disk Table This table describes available properties for each physical array disk on the managed system The following object sets up the Array Disk Table Name arrayDiskTable Object ID 1 3 6 1 4 1 674 1
86. Read only Cluster State Capabilities Name clusterStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 3 Description Defines the state capabilities of the cluster Syntax DellStateCapabilities Access Read only Cluster State Settings Name clusterStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 4 Description Defines the state settings of the cluster Syntax DellStateSettings Access Read write 518 Cluster Group Cluster Status Name Object ID Description Syntax Access Cluster Type Name Object ID Description Syntax Access clusterStatus 1 3 6 1 4 1 674 10892 1 1800 10 1 5 Defines the status of the cluster DellStatus Read only clusterType 1 3 6 1 4 1 674 10892 1 1800 10 1 6 Defines the type of the cluster DellClusterType Read only Cluster Type Description Name Name Object ID Description Syntax Access Cluster Name Name Object ID Description Syntax Access clusterTypeDescriptionName 1 3 6 1 4 1 674 10892 1 1800 10 1 7 Defines the description name for the type of the cluster DellString Read only clusterName 1 3 6 1 4 1 674 10892 1 1800 10 1 8 Defines the name of the cluster DellString Read only Cluster Group 519 Cluster Group Variable Values This section includes definitions for Server Administrator specific variable values used in this section Table 20 1 Cluster Type Variable Name De11ClusterType Data Type Integer Possible Data
87. Resource Interrupt Table Syntax SEQUENCE OF SystemResourcelnterruptTableEntry Access Not accessible System Resource Interrupt Table Entry Name systemResourcelInterruptTableEntry Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 Description Defines the System Resource Interrupt Table entry Syntax SystemResourcelnterrupt TableEntry Access Not accessible Index systemResourcelnterruptchassisIndex systemResourcelnterruptIndex System Resource Interrupt Chassis Index Name systemResourcelInterruptchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Not accessible 138 System Resource Group System Resource Interrupt Index Name Object ID Description Syntax Access systemResourcelInterrupt Index 1 3 6 1 4 1 674 10892 1 500 50 1 2 Defines the index one based of this interrupt resource DellObjectRange Read only System Resource Interrupt State Capabilities Name Object ID Description Syntax Access systemResourcelInterruptStateCapabilities 1 3 6 1 4 1 674 10892 1 500 50 1 3 Defines the capabilities of this system resource interrupt DellStateCapabilities Read only System Resource Interrupt State Settings Name Object ID Description Syntax Access systemResourceInterruptStateSettings 1 3 6 1 4 1 674 10892 1 500 50 1 4 Defines the state of this system resource interrupt DellStateSettings
88. Storage Management Alert Reference The alert severity levels are as follows Table 27 1 Storage Management Alert Severity Alert Severity Component Status OK Normal Informational No action is required The alert is provided for informational purposes and does not indicate an error condition For example the alert may indicate the normal start or stop of an operation Warning Non critical A component requires attention This alert indicates a potential problem but does not necessarily mean that the system has currently lost data or is nonfunctional For example a Warning Non critical alert may indicate that a component such as a temperature probe in an enclosure has crossed a warning threshold Critical Failure Error A component has either failed or failure is imminent This alert indicates a serious problem such as data loss or a loss of function For example a Critical Failure Error alert may indicate that an array disk has failed SNMP Support for Storage Management Alerts By default Storage Management installs SNMP trap forwarding support For this support to function you should have SNMP installed on the managed system prior to installing Storage Management NOTE For more information on installation requirements and SNMP see the Server Administrator documentation SNMP Trap Forwarding The Storage Management alerts are displayed in the Server Administrator alert log and are forwarded to the Window
89. Switching DBS enabled Bit 2 eXecute Disable XD enabled Bit 3 Hyper Threading HT enabled DellUnsigned16BitRange Read only Processor Device Brand Name Syntax Access Name Object ID Description processorDeviceBrandName 1 3 6 1 4 1 674 10892 1 1100 30 1 23 Defines the brand of the processor device DellString Read only Processor Device Model Name Description Syntax Access 272 Object ID processorDeviceModelNam 1 3 6 1 4 1 674 10892 1 1100 30 1 24 Defines the model of the processor device DellString Read only Device Group Processor Device Stepping Name Name Object ID Description Syntax Access processorDeviceSteppingName 1 3 6 1 4 1 674 10892 1 1100 30 1 25 Defines the stepping of the processor device DellString Read only Processor Device Status Table Name Object ID Description Syntax Access processorDeviceStatusTable 1 3 6 1 4 1 674 10892 1 1100 32 Defines the Processor Device Status Table SEQUENCE OF ProcessorDeviceStatus TableEntry Not accessible Processor Device Status Table Entry Name Object ID Description Syntax Access Index processorDeviceStatusTableEntry 1 3 6 1 4 1 674 10892 1 1100 32 1 Defines the Processor Device Status Table Entry ProcessorDeviceStatusTableEntry Not accessible processorDeviceStatusChassisIndex processorDeviceStatusIndex Processor Device Status Chassis Index Name Object ID Description Syntax Ac
90. Table 91 Firmware Table 000 97 Intrusion Table 00004 100 Baseboard Table 05 102 Chassis Information Group Variable Values 107 6 Operating System Group 121 Operating System Group Table 121 Operating System Table 121 Contents Operating System Memory Table 7 System Resource Group System Resource Group Tables System Resource Map Table System Resource Owner Table System Resource Input Output 1 0 Port Tables iann cn sod Fp ad ee a eae System Resource Memory Table System Resource Interrupt Table System Resource Direct Memory Access DMA Table System Resource Group Variable Values 8 PowerGroup PowerGroupTables Power UnitTable Power Supply Table Voltage Probe Table Amperage Probe Table AC Power Switch Table AC PowerCordTable BatteryTable 000 4 Power Usage Table Power Profile Table Power Group Variable Values 9 ThermalGroup Thermal Group Tables Cooling Unit Table Cooling Device Table 200 Temperature Probe Table 205 Therma
91. Table The following object sets up the Temperature Probe Connection Table Name Object ID Description Syntax Access temperatureConnectionTable 1 3 6 1 4 1 674 10893 1 20 130 12 Defines the temperature probe connection table SEQUENCE OF TemperatureConnectionEntry Not accessible Temperature Probe Connection Entry Name Object ID Description Syntax Access Index temperatureConnectionEntry 1 3 6 1 4 1 674 10893 1 20 130 12 1 Defines the temperature probe connection table entry TemperatureConnectionEntry Not accessible temperatureConnectionNumber Storage Management Group 623 Temperature Probe Connection Number Name temperatureConnectionNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 12 1 1 Description Identifies the instance number of the temperature probe connection entry Syntax Integer Access Read only Temperature Probe Connection Temperature Probe Name Name temperatureConnectionTemperatureNam Object ID 1 3 6 1 4 1 674 10893 1 20 130 12 1 2 Description Identifies the name of the temperature probe in this connection as represented in Storage Management Syntax DisplayString Access Read only Temperature Probe Connection Temperature Probe Number Name temperatureConnectionTemperatureNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 12 1 3 Description Identifies the instance number in the temperatureTable of the temperature probe in this connection Syntax In
92. The processor family is Pentium II deviceFamilyIsPent iumMMX 14 The processor family is Pentium MMx deviceFamilyIsCeleron 15 The processor family is Celeron deviceFamilyIsXeon 16 The processor family is Xeon deviceFamilyIsPentium3 17 The processor family is Pentium IIL deviceFamilyIsPentium3Xeon 18 The processor family is Pentium III Xeon deviceFamilyIsPentium3Step 19 The processor family is Pentium III Speed Step deviceFami 20 lyIsPentiumItanium The processor family is Itanium deviceFamilyIsIntelXeon 21 The processor family is Intel Xeon deviceFamilyIsPentium4 22 The processor family is Pentium 4 deviceFamilyIsIntelXeonMP 23 The processor family is Intel Xeon MP deviceFamilyIsIntelItanium2 24 The processor family is Intel Itanium 2 deviceFamilyIsK5 25 The processor family is K5 deviceFamilyIsk6 26 The processor family is K6 deviceFamilyIsK6 2 27 The processor family is K6 2 deviceFamilyIsk6 3 28 The processor family is K6 3 322 Device Group Table 13 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDAthlon 29 The processor family is AMD Athlon deviceFamilyIsAMD2900 30 The processor family is AMD2900 deviceFamilyIsK
93. Trap ID Description Severity Cause Pluggable Device Removal 1652 Device removed from system Information A device was removed from aaphES Moeseteny aie no The skoct on Ao chassis evice ocation chassis location and additional Chassis Location lt Name event details if available Of chassis gt are provided Additional Details lt Additional details for the events gt Pluggable Device Configuration Error 1653 Device configuration error Error A configuration error was detected detected for a pluggable Haha Location device in the specified Sisaiiee in chasus system The device may have been added to the Chassis LOCAETONS lt Name system incorrectly The of chassis gt device location chassis Additional Details lt Additional location and additional details for the events gt event details if available are provided Battery Traps The BMC on some systems reports the status of batteries Battery traps provide status and warning information for batteries present in a system with a BMC that reports the status of batteries 722 Traps Table 26 16 Battery Traps Trap ID Description Severity Cause Battery Normal 1702 Battery sensor returned Information A battery sensor in the to a normal value Sensor Location lt Location in chassis gt Chassis Location of chassis gt lt Name Previous state was lt State gt Battery sensor status lt status gt specified system detected that a battery tra
94. USB Control Settings Name usbControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 4 BIOS Setup Control Group 401 Name usbControlSettings Description Defines the control settings for the USB Syntax DellStateSettings Access Read only USB Control Status Name usbControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 5 Description Defines the status of the USB Syntax DellStatus Access Read only USB Control Name Name usbControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 6 Description Defines the setup BIOS name of the USB Syntax DellString Access Read only IDE Control Table These objects enable you to track the attributes of Integrated Device Electronics IDE controller cards in your system Name ideControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 60 Description Defines the IDE Control Table Syntax IdeControl TableEntry Access Not accessible 402 BIOS Setup Control Group IDE Control Table Entry Name Object ID Description Syntax Access Index ideControlTableEntry 1 3 6 1 4 1 674 10892 1 1400 60 1 Defines the IDE Control Table entry IdeContro TableEntry Not accessible ideControlchassisIndex ideControllndex IDE Control Chassis Index Name Object ID Description Syntax Access IDE Control Index Name Object ID Description Syntax Access ideControlchassisIndex 1 3 6 1 4 1 674 10892 1 1400 60 1 1 Defines the index one based of this chassis DellObje
95. Values Meaning of Data Value unknown 1 The cluster type is unknown highAvailabilityCluster 2 The cluster type is a high availability cluster 520 Cluster Group Baseboard Management Controller Group The Baseboard Management Controller BMC monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds The BMC Group provides information about the BMC that may be present in your system In addition to providing general information about the BMC this group provides information about the serial and local area network LAN interfaces of the BMC Baseboard Management Controller Group Tables The objects in the BMC group define information about the BMC and the serial and LAN interfaces that can be used to access the BMC remotely to perform management activities Objects for the serial interface define the serial connection mode flow control type and bit rate Objects for the LAN interface define the media access control MAC address internet protocol IP address subnet mask and default gateway The following MIB tables define the BMC group e Baseboard Management Controller Table e Baseboard Management Controller Serial Interface Table e Baseboard Management Controller LAN Interface Table Baseboard Management Controller Table Name bmcTable Object ID 1 3 6 1 4 1 674 10892 1 1900 10 Descrip
96. a centrifugal blower coolingDeviceTypelIsAChipFan 5 The cooling device type is a fan on an integrated circuit coolingDeviceTypelIsACabinetFan 6 The cooling device type is a cabinet fan coolingDeviceTypelIsAPowerSupplyFan 7 The cooling device type is a power supply fan coolingDeviceTypelIsAHeat Pipe 8 The cooling device type is a heat pipe coolingDeviceTypelIsRefrigeration 9 The cooling device type is an integrated refrigeration unit coolingDeviceTypelsActiveCooling 10 The cooling device type is an active cooling device coolingDeviceTypelIsPassiveCooling 11 The cooling device type is a YP passive cooling device Thermal Group 211 Table 9 2 Cooling Device Subtype Variable Name De 1 1CoolingDeviceSubType Data Type Integer Possible Data Values Meaning of Data Value coolingDeviceSubTypelIsOther 1 The cooling device subtype is not one of the following coolingDeviceSubTypelIsUnknown 2 The cooling device subtype is unknown not known or not monitored coolingDeviceSubTypelIsAFanThatReads InRPM 3 The cooling device subtype is a fan that reads in RPMs coolingDeviceSub OFF 4 TypelsAFanReadsONor The cooling device subtype is a fan that reads 0 off or 1 on coolingDeviceSubTypelsAPowerSupply FanThatReadsinRPM 5 The cooling device subtype is a power supply f
97. and managed systems communicate over a network typically through User Datagram Protocol Internet Protocol UDP IP The management system and a managed system communicate by means of a common data schema SNMP MIB files define the structure type and values of the SNMP data While MIBs can be standardized or enterprise specific most operating systems supply SNMP agents for the standard MIB I and MIB II schemas MIB I defines a base set of standard management information for systems implementing the Internet Protocol IP suite MIB II defines characteristics of the system characteristics of network interfaces and characteristics of components of the IP on the system In addition to the standard MIBs many hardware vendors have defined MIBs that provide management data specific to their systems and peripheral devices Monitored data can be retrieved through SNMP using the Get command Typically this command requires the host name or IP address of the target machine as well as the OID of the data to retrieve Exact details are dependent on the operating system and the development tools being used to create the management application The Get command has a variant known as GetNext Introduction 39 SNMP MIB OIDs Each data class within an MIB is defined by an OID OIDs are unique across all MIBs An OID consists of a series of digits separated by periods The OID functions in a similar fashion to a phone number The phone number 011 512
98. and time gt Specifies the date and time that an automatic server recovery action was performed for example Date and time of action Fri May 30 23 55 44 2003 Description lt Description of event gt Specifies the description of the event that occurred for example Description Chipset Err Critical Event sensor front panel NMI diagnostic interrupt was asserted Device location lt Location in chassis gt Specifies the location of the device in the specified chassis for example Device location Mem Card A Discrete current state lt State gt Specifies the state of the current sensor for example Discrete current state Good Traps 695 Table 26 1 Trap Description Reference continued Description Line Item Explanation Discret state temperatur lt State gt Specifies the state of the temperature sensor for example Discret state Good temperatur Discrete voltage state lt State gt Specifies the state of the voltage sensor for example Discrete voltage state Good Fan sensor value Specifies the fan speed in revolutions per lt Reading gt minute RPMs or On Off for example Fan sensor value in RPM 2600 Fan sensor value Off Log type lt Log type gt Specifies the type of hardware log for example Log typ Embedded Server Management ESM Memory device bank location lt Bank name in ch
99. as SNMP traps to other applications SNMP traps that are generated for the alerts are included in the Storage Management MIB The SNMP traps for these alerts use all of the SNMP trap variables For the list of storage management alerts and storage management messages see the Dell OpenManage Server Administrator Messages Reference Guide available on the Dell Support website at support dell com manuals Storage Management Alert Reference 741 742 Storage Management Alert Reference Standard Data Type Definitions This appendix contains definitions for data types that are standard in most contexts across the information technology industry These are the most common data types for describing variable values defined in the 10892 mib dcs3rmt mib and des3fru mib files Server Administrator specific variable values are defined in the last section of the section in which they are introduced Common Data Types Common data types include several types of strings the object range signed and unsigned bit ranges and the familiar Boolean true or false data type Table A 1 Common Data Types Variable Name Definition DellString DisplayString SIZE 0 64 DellSecurityString DisplayString SIZE 0 255 DellCostofOwnershipString DisplayString SIZE 0 64 DellObjectRange INTEGER 1 128 DellUnsigned8BitRange INTEGER 1 256 DellUnsigned16BitRange INTEGER 1 65535 DellUnsigned32BitR
100. batteryName Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 2 Description Identifies the battery s name as represented in Storage Management Syntax DisplayString Access Read only Battery Vendor Name batteryVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 3 Description Identifies the battery s re seller s name Syntax DisplayString Access Read only Battery State Name batteryState Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 4 Description Identifies the current state of battery Possible values 0 Unknown 1 OK 2 Failed 6 Degraded 7 Reconditioning 9 High 10 Low 12 Charging 21 Missing 36 Learning Syntax Integer Access Read only 634 Storage Management Group Battery Roll Up Status Name Object ID Description Syntax Access batteryRollUpStatus 1 3 6 1 4 1 674 10893 1 20 130 15 1 5 Severity of the battery state This is the combined status of the battery and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Battery Component Status Name Object ID Description Syntax Access batteryComponentStatus 1 3 6 1 4 1 674 10893 1 20 130 15 1 6 The status of the battery itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Storage Management Group 635
101. binary octet string Each byte of the octet string represents the state of a specific temperature probe The first byte returned represents the state of the first temperature probe the second byte returned represents the status of the second temperature probe and so on The bytes have the same definition type as DellStateSettings Syntax OCTET STRING SIZE 1 128 Access Read only System State Temperature Status Combined Name systemStateTemperatureStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 24 Description Defines the status of all temperature probes in this chassis The result is returned as a combined status value The value has the same definition type as DellStatus Syntax DellStatus Access Read only System State Temperature Status Details Name systemStateTemperatureStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 25 Description Defines the status of all temperature probes in this chassis The first byte returned represents the status of the first temperature probe the second byte returned represents the status of the second temperature probe and so on Syntax OCTET STRING SIZE 1 128 Access Read only System State Group 59 System State Memory Device State Details Name systemStateMemoryDeviceStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 26 Description Defines the state of all memory devices in this chassis The results are returned as a binary octet string Each by
102. chassis gt thresho ye SENSOL location chassis Chassis location lt Name of location previous state chassis gt and voltage sensor value Previous state was lt State gt are provided If sensor type is not discrete Voltage sensor value in Volts lt Reading gt If sensor type is discrete Discrete voltage state lt State gt Voltage Probe Nonrecoverable 1155 Voltage sensor detected a Error A voltage sensor in the non recoverable valu Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Voltage sensor value Volts lt Reading gt in If sensor type is discrete Discrete voltage state lt State gt specified system detected an error from which it cannot recover The sensor location chassis location previous state and voltage sensor value are provided Traps 707 Amperage Probe Traps Amperage probes measure the amount of current in amperes that is traversing critical components Table 26 6 Amperage Probe Traps Trap ID Description Cause Amperage Probe Normal 1202 Current sensor returned to a normal value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Current sensor value in Amps lt Reading gt If sensor type is discrete Discrete c
103. connection table Syntax SEQUENCE OF EnclosureManagementModuleConnectionEntry Access Not accessible 630 Storage Management Group Enclosure Management Module Connection Entry Name Object ID Description Syntax Access Index enclosureManagementModuleConnectionEntry 1 3 6 1 4 1 674 10893 1 20 130 14 1 Defines the enclosure memory module connection table entry EnclosureManagementModuleConnectionEntry Not accessible enclosureManagementModuleConnectionNumber Enclosure Management Module Connection Number Name Object ID Description Syntax Access enclosureManagementModuleConnectionNumber 1 3 6 1 4 1 674 10893 1 20 130 14 1 1 Identifies the instance number of the enclosure memory module connection entry Integer Read only Enclosure Management Module Connection EMM Name Name Object ID Description Syntax Access enclosureManagementModuleConnect ionEMMName 1 3 6 1 4 1 674 10893 1 20 130 14 1 2 Identifies the name of the enclosure memory module in this connection as represented in Storage Management DisplayString Read only Storage Management Group 631 Enclosure Management Module Connection EMM Number Name enclosureManagementModuleConnect ionEMMNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 14 1 3 Description Identifies the instance number in the enclosureManagementModule able of the enclosure memory module in this connection Syntax Integer Access Read only Enclo
104. detected Table 8 16 Power Cap Capabilities Variable Name De 1 1PowerCapCapabilities Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value none 0 No power cap capabilities are available enable 1 Power cap can be enabled Power Group 193 Table 8 16 Power Cap Capabilities Variable Name De 1 1PowerCapCapabilities Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value disable 2 Power cap can be disabled Table 8 17 Power Cap Setting Variable Name De11PowerCapSetting Data Type Integer Possible Data Values Meaning of Data Value disabled 0 Power cap is disabled enabled 1 Power cap is enabled Table 8 18 Power Profile Type Variable Name De 1 1PowerProfileType Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value maxPer formance 1 Power profile type is Maximum Performance osControl 2 Power profile type is OS control activePowerController 4 Power profile type is Active Power Controller custom 8 Power profile type is Custom 194 Power Group Table 8 19 CPU Power Performance Management Type Variable Name De 1 1 CPUPowerPerformanceManagementTyp Data Type Integer N
105. did restored not have AC power has had Bel ons Sp pease Hes the hs oe r l LR beer Os in Chagoo sensor ocation and chassis location information are Chassis location provided lt Name of chassis gt AC Power Cord Failure 1504 AC power has been lost Error An AC power cord has lost Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt its power The sensor location and chassis location information are provided Hardware Log Traps Hardware logs provide hardware status messages to systems management software On certain systems the hardware log is implemented as a circular queue When the log becomes full the oldest status messages are overwritten when new status messages are logged On some systems the log is not circular On these systems when the log becomes full subsequent hardware status messages are lost Hardware log sensor messages provide status and warning information about the noncircular logs that may fill up resulting in lost status messages 718 Traps Table 26 13 Hardware Log Traps Trap ID Description Severity Cause Hardware Log Normal 1552 Log size is no longer Information The hardware log on the near or at capacity specified system is no Tog typen ance typis longer near or at its capacity usually as the result of clearing the log The log type information is provided Hardware Log Warning 1553 Log size is near or at Warning The size of a hardw
106. extended warranty start date for this system DellDateName Read write COO Extended Warranty End Date Name Name Object ID Description Syntax Access cooExtendedWarrant yEndDateName 1 3 6 1 4 1 674 10892 1 1600 10 1 14 Defines the extended warranty end date for this system DellDateName Read write COO Extended Warranty Cost Name Object ID Description Syntax Access cooExtendedWarrantyCost 1 3 6 1 4 1 674 10892 1 1600 10 1 15 Defines the extended warranty cost date for this system DellUnsigned32BitRange Read write Cost of Ownership Group 431 COO Extended Warranty Provider Name Name cooExtendedWarrant yProviderName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 16 Description Defines the name of the extended warranty provider for this system Syntax DellCostofOwnershipString Access Read write COO Ownership Code Name cooOwnershipCode Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 17 Description Defines the ownership code for this system Syntax DellCooOwnershipCodes See Table 18 1 Access Read write COO Corporate Owner Name Name cooCorporateOwnerName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 18 Description Defines the name of the corporation that owns this system Syntax DellCostofOwnershipString Access Read write COO Hazardous Waste Code Name Name cooHazardousWasteCodeName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 19 Description Defines the hazardous waste code for t
107. for this remote access user Syntax DellUnsigned32BitRange Access Read write Remote User Admin Alert Filter System Events Mask Name remoteUserAdminAlertFilterSysEventsMask Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 12 Description Defines the system events filter mask for this remote access user Syntax DellUnsigned32BitRange Access Read write 480 Remote Access Group Remote User Admin Alert Filter DRS Capabilities Name Object ID Description Syntax Access remoteUserAdminAlertFilterDrsCapabilities 1 3 6 1 4 1 674 10892 1 1700 20 1 13 Defines the DRS events filter capabilities for this remote access user DellUnsigned32BitRange Read only Remote User Admin Alert Filter System Capabilities Name Object ID Description Syntax Access remoteUserAdminAlertFilterSysCapabilities 1 3 6 1 4 1 674 10892 1 1700 20 1 14 Defines the system events filter capabilities for this remote access user DellUnsigned32BitRange Read only Remote User Admin Pager Numeric Number Name Name Object ID Description Syntax Access remot eUserAdminPagerNumericNumberName 1 3 6 1 4 1 674 10892 1 1700 20 1 15 Defines the numeric pager number for this remote access user DisplayString SIZE 0 95 Read write Remote User Admin Pager Numeric Message Name Name Object ID Description Syntax Access remoteUserAdminPagerNumericMessageNam 1 3 6 1 4 1 674 10892 1 1700 20 1 16 Defines the message to sen
108. indicating a expired system hang indicating a system hang Traps 727 Table 26 19 Enterprise specific Traps continued Trap Name Description Severity Category Cause Supported ID by RAC Platform 1008 alertDrscBatt The RAC Minor Error RAC DRAC III Low Battery detected its charge is battery below 25 charge is indicating below 25 that the full battery may only be able to power the DRSC for 8 10 minutes 1009 alertDrscTemp The RAC Information Status RAC DRAC III Normal Temperature temperature probe has probe reading returned returned to to a normal normal value 1010 alertDrscTemp The RAC Minor Status RAC DRAC III Warning Temperature temperature probe has probe reading detected a exceeded Warning warning value threshold 1011 alertDrscTemp The RAC Critical Error RAC DRAC III Critical Temperature temperature probe has probe reading detected a exceeded failure critical or threshold critical value 728 Traps Table 26 19 Enterprise specific Traps continued Trap Name Description Severity Category Cause Supported ID by RAC Platform 1012 alertDrscVolt The RAC Information Error RAC voltage DRAC III Normal voltage probe reading has returns to returned normal to a normal value 1013 alertDrscVolt The RAC Minor Error RAC voltage DRAC III Warning voltage probe reading probe has exceeded detected a warning warning threshold value 1014 alertDrscVolt The RAC Critical Error RAC v
109. is Intel Celeron M deviceFamil yIsAMDAthlon64 131 The processor family is AMD Athlon 64 deviceFamil yIsAMDOpteron 132 The processor family is AMD Opteron deviceFamil yIsAMDSempron 133 The processor family is AMD Sempron deviceFamilyIsAMDTurion64Mobile 134 The processor family is AMD Turion 64 Mobile Technology deviceFamilyIsDualCoreAMDOpter on 135 The processor family is Dual Core AMD Opteron deviceFamilyIsAMDAthlon64X2Dual Core 136 The processor family is AMD Athlon 64 X2 Dual Core deviceFamilyIsAMDTurion64X2Mob ile 137 The processor family is AMD Turion 64 X2 Mobile Technology Device Group 325 Table 13 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsQuadCoreAMDOpter on 138 The processor family is Quad Core AMD Opteron deviceFamilyIsThirdGenerationA MDOpteron 139 The processor family is third generation AMD Opteron deviceFamilyIsAMDPhenomF xXQuadC ore 140 The processor family is AMD Phenom FX Quad Core deviceFamilyIsAMDPhenomx4QuadC ore 141 The processor family is AMD Phenom X4 Quad Core deviceFamilyIsAMDPhenomxX2DualC ore 142 The processor family is AMD Phenom X2 Dual Core deviceFamilyIsAMDAthlonX2DualC ore 143 The proce
110. is a bit field where a bit has the meaning defined below when set to 1 one NOTE Bits 2 15 need to be examined in the context of bit 1 If bit 1 is set the processor characteristics are unknown and bits 2 15 cannot be used to determine if the functions associated with the bits are supported Bit Position Meaning if Set Bit 0 Reserved Bit 1 Unknown Bit 2 64 bit capable Bit 3 15 Reserved DellUnsigned16BitRange Read only Processor Device Extended Capabilities Name Object ID Description Syntax Access processorDeviceExtendedCapabilities 1 3 6 1 4 1 674 10892 1 1100 30 1 21 This attribute defines extended capabilities of the processor device This attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit Position Meaning if Set Bit 0 Virtualization Technology VT supported Bit 1 Demand Based Switching DBS supported Bit 2 eXecute Disable XD supported Bit 3 Hyper Threading HT supported DellUnsigned16BitRange Read only Device Group 271 Processor Device Extended Settings Access Name Object ID Description Syntax processorDeviceExtendedSettings 1 3 6 1 4 1 674 10892 1 1100 30 1 22 This attribute defines extended settings of the processor device This attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit Position Meaning if Set Bit 0 Virtualization Technology VT enabled Bit 1 Demand Based
111. location of the CMC PSU Syntax DellString Access Read only DRsPSUMonitoringCapable Name DRsPSUMonitoringCapable Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 4 Description Defines the PSU Monitoring capabilities or the absence of a PSU in this location Syntax DellCMCPSUCapable Access Read only DRsPSUVoltsReading Name DRsPSUVoltsReading Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 5 Description Defines the instantaneousPSU Voltage reading Syntax DellPowerReading Access Read only 686 Dell RAC Out of Band Group DRsPSUAmpsReading Name DRsPSUAmpsReading Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 6 Description Defines the instantaneous PSU Current reading Syntax DellPowerReading Access Read only DRsPSUWattsReading Name DrsPSUWattsReading Object ID 1 3 6 1 4 1 674 10892 2 4 2 1 7 Description Defines the instantaneous PSU Wattage reading Syntax DellPowerReading Access Read only Chassis Alerts The following MIB tables provide information on the chassis management controller alerts DRsCASubSystem Name DrsCASubSystem Object ID 1 3 6 1 4 1 674 10892 2 20 10 1 Description Defines the Sub System Name of the CMC Alert Syntax DellString Access Read only Dell RAC Out of Band Group 687 DrsCASSCurrStatus Name DrsCASSCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 20 10 2 Description Defines the Current Status of the Alerting Sub System Syntax DellStatus Access Read only DrsCASSPrevStatus Name DrsCASSP
112. monitorPortBlOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 9 Description Defines the name of the BIOS connector type of the monitor port Syntax DellGenericPortConnectorType Access Read only PortGroup 239 Small Computer System Interface SCSI Port Table Name sCSIPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 60 Description Defines the SCSI Port Table Syntax IntegerSCS PortTableEntry Access Not accessible SCSI Port Table Entry Name sCSIPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 Description Defines the SCSI Port Table entry Syntax SCSIPortTableEntry Access Not accessible Index sCS PortchassisIndex sCSIPortIndex SCSI Port Chassis Index Name sCSIPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only SCSI Port Index Name sCSIPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 2 Description Defines the index of the SCSI ports in this chassis Syntax DellObjectRange Access Read only 240 Port Group SCSI Port State Capabilities Name Object ID Description sCSIPortStateCapabilities 1 3 6 1 4 1 674 10892 1 1000 60 1 3 Defines the capabilities of the SCSI port Syntax DellStateCapabilities Access Read only SCSI Port State Settings Name DellStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 4 Description Defines the state and settings of the SCSI por
113. not ready completionCodeIsDisabled 7 Flash BIOS is currently disabled completionCodeIsNoBattery 8 A battery must be installed complet ionCodeIsNoChargedBattery 9 A fully charged battery must be installed complet ionCodeIsNoExternalPower 10 An external power adapter must be connected completionCodeIsNol2VoltSet 11 12 volts V could not be set complet ionCodeIsNo12VoltRemoval 12 12 V could not be removed completionCodeIsFlashMemoryFailed A flash memory failure occurred 13 completionCodeIsGeneralFailure 14 A general failure occurred completionCodeIsDataMiscompare 15 A data miscompare error occurred complet ionCodeIsNoImageFound 16 The flash BIOS image could not be found in memory completionCodeIsNoUpdatePerformed No update operation has been 17 performed Remote Flash BIOS Group 223 224 Remote Flash BIOS Group Port Group The Port Group provides information about the different types of ports that may be present in your system This management information base MIB group also provides information about the capabilities states and settings that are possible for each port Port Group Tables The following MIB tables define objects in the Port Group Pointing Port Table Keyboard Port Table Processor Port Table Memory Device Port Table Monitor Port Table Small Computer System Interface SCSI Port Table Parallel Port Table Ser
114. of the health of critical components The Server Administrator Instrumentation MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information Table 1 2 describes each Server Administrator Instrumentation MIB group Introduction 23 and lists the MIB group number assigned to the MIB group The Server Administrator Instrumentation MIB groups are identified by the SNMP OID 1 3 6 1 4 1 674 10892 1 lt MIB group number gt where lt MIB group number gt is the MIB group number assigned to the MIB group See the relevant section for more information about the MIB objects defined in a MIB group Table 1 2 Server Administrator Instrumentation MIB Sections in This Guide Section Topics MIB Group Numbers 2 Instrumentation MIB Version Group defines version l numbers of the Instrumentation MIB 3 Systems Management Software Group defines information 100 about the systems management software and the supported systems management standards 4 System State Group defines status state and redundancy for 200 a system and its components 5 Chassis Information Group defines chassis types events and 300 indicators 6 Operating System Group defines variables for name version 400 service pack and other information about a system s operating system 7 System Resource Group defines variables for input output 500 ports memory interrupts and dir
115. on the controller Syntax Integer Access Read only Controller Check Consistency Rate Name controllerCheckConsistencyRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 51 Description The rate for check consistency on the controller Syntax Integer Access Read only 568 Storage Management Group Controller Patrol Read Mode Name Object ID Description Syntax Access controllerPatrolReadMode 1 3 6 1 4 1 674 10893 1 20 130 1 1 52 Identifies the patrol read mode Possible values 1 Automatic enabled 2 Manual enabled 3 Disabled Integer Read only Controller Patrol Read State Name Object ID Description Syntax Access controllerPatrolReadState 1 3 6 1 4 1 674 10893 1 20 130 1 1 53 The state of the patrol read Possible values 1 Stopped not running 2 Ready ready to start 4 Active is running 8 Aborted has aborted Integer Read only Controller Patrol Read Iterations Name Object ID Description Syntax Access controllerPatrolReadIterations 1 3 6 1 4 1 674 10893 1 20 130 1 1 54 The number of times Patrol Read has been run on this controller Integer Read only Storage Management Group 569 Channel Table This table describes available properties for each channel on the managed system The following object sets up the Channel Table Name channelTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 Description Defines the channel table Syntax SEQUENCE OF Cha
116. only Controller Severity Name controllerSeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 6 Description This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Syntax Integer Access Read only Controller Rebuild Rate in Percent Name controllerRebuildRateInPercent Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 7 Description Identifies the percent of the compute cycles dedicated to rebuilding failed array disks Syntax Integer Access Read only 556 Storage Management Group Controller Firmware Version Name Object ID Description Syntax Access controllerFWVersion 1 3 6 1 4 1 674 10893 1 20 130 1 1 8 Identifies the controller s current firmware version DisplayString Read only Controller Cache Size in Megabytes Name Object ID Description Syntax Access controllerCacheSizeInMB 1 3 6 1 4 1 674 10893 1 20 130 1 1 9 Identifies the controller s current amount of cache memory in megabytes If this size is 0 it is less than a megabyte Integer Read only Controller Cache Size in Bytes Name Object ID Description Syntax Access controllerCacheSizeInBytes 1 3 6 1 4 1 674 10893 1 20 130 1 1 10 Identifies the controller s current amount of cache memory that is less than a megabyte This combined with the controllerCacheSizeInMB will be the total amount of memory Integer Read only Controller Physical Device Count
117. processor family is microSPARC Iep deviceFamilyIsUltraSPARC 84 The processor family is UltraSPARC deviceFamilyIsUltraSPARCII 85 The processor family is UltraSPARC II deviceFamilyIsUltraSPARCITi 86 The processor family is UltraSPARC Ili deviceFamilyIsUltraSPARCIII 87 324 Device Group The processor family is UltraSPARC III Table 13 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsUltraSPARCIITi The processor family is UltraSPARC IIi 88 deviceFamilyIs68040 96 The processor family is 68040 Family deviceFamilyIs68xxx 97 The processor family is 68xxx deviceFamilyIs68000 98 The processor family is 68000 deviceFamilyIs68010 99 The processor family is 68010 deviceFamilyIs68020 100 The processor family is 68020 deviceFamilyIs68030 101 he processor family is 68030 deviceFamilyIsHobbit 112 he processor family is Hobbit deviceFamilyIsCrusoeTM5000 120 he processor family is Crusoe TM5000 deviceFamilyIsCrusoeTM3000 121 deviceFamilyIsEfficeonTM8000 122 he processor family is Efficeon M8000 deviceFamil yIsWeitek 128 T T T The processor family is Crusoe TM3000 T T T he processor family is Weitek deviceFamil 0 yIsIntelCeleronM 13 The processor family
118. read only or read write e Index or indexes if applicable For each MIB group that has unique variable definitions tables are included in the last section of the section to explain the meaning of the terms 38 Introduction Standards for writing MIBs are defined by the Internet Engineering Task Force IETF Structure of Management Information SMI is a standard that specifies the rules for defining the structure and type of managed objects and events in a MIB SMIv1 is specified in Request For Comments RFC 1155 The Server Administrator MIB conforms to the SMIv1 standard SNMP is a systems management standard originally designed for network management SNMP manages much more than networks Information Technology IT professionals use SNMP for monitoring and managing computer systems and the various components and peripherals supported by their systems SNMP standards are defined by the Internet Engineering Task Force IETF SNMP version 1 was published in August 1988 and is the most commonly supported version of SNMP SNMP version 2 was first published in May 1993 but has not gained widespread market acceptance SNMP version 3 was recently completed and has addressed security issues that exist in version 1 All SNMP systems consist of one or more managed systems that provide data through an SNMP agent to a management system The management system provides a user interface to view data from the managed systems The management system
119. set to indicate not ready cancelCapable 8 Flash of BIOS can be canceled enableAndCancelCapable 10 Flash of BIOS can be enabled or canceled Table 11 2 Remote Flash BIOS State Settings Variable Name De 1 1RemoteFlashBlIOSStateSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The remote flash BIOS s capabilities are unknown enabled 2 The remote flash BIOS update is disabled offline a binary 0 value or enabled online a binary value not Ready 4 The remote flash BIOS s state is not ready canceled 8 The remote flash BIOS has been canceled pending 16 The remote flash BIOS update is pending other 32 The remote flash BIOS state setting is not one of the previous values 222 Remote Flash BIOS Group Table 11 3 Remote Flash BIOS Completion Code Variable Name De 1 1RemoteFlashBIOSCompletionCode Data Type Integer Possible Data Values Meaning of Data Value complet ionCodelIsOther 1 The completion code status is not one of the following complet ionCodeIsUnknown 2 The completion code is unknown not known or not monitored complet ionCodeIsOK 3 This completion code completed successfully complet ionCodeIsBadImage 4 This completion code is a bad flash BIOS image completionCodeIsNoFileAccess 5 Flash BIOS could not be accessed complet ionCodeIsNotReady 6 Flash BIOS memory
120. systemBackP lane 6 The firmware type is System Primary Backplane powerVault2XxXSKernel 7 The firmware type is Dell PowerVault 2XXS Kernel powerVault2XXSApplication 8 The firmware type is PowerVault 2XXS Application frontPanel 9 The firmware type is Front Panel Controller baseboardManagementController The firmware type is Baseboard 10 Management Controller hotPlugPCI 11 The firmware type is Hot Plug Peripheral Component Interconnect PCI Controller sensorData 12 The firmware type is Sensor Data Records peripheralBay 13 The firmware type is Peripheral Bay Backplane secondaryBackPlane 14 The firmware type is Secondary Backplane for ESM 2 systems secondaryBackPlaneESM3And4 15 The firmware type is Secondary Backplane for ESM 3 and 4 systems 118 Chassis Information Group Table 5 22 Firmware Type continued Variable Name De11FirmwareType Data Type Integer Possible Data Values Meaning of Data Value rac 16 The firmware type is Remote Access Controller iDRAC 17 The firmware type is Integrated Dell Remote Access Controller Table 5 23 Baseboard Type Variable Name De 1 1BaseBoardType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The baseboard type is unknown other 2 The baseboard type is not one of the following types serverBlade 3 The baseboard type is a server
121. total wattage used in Watt hours by this entity since the date and time specified by the powerUsageCumulative WattageStartDateName attribute DellUnsigned32BitRange Read only Power Usage Cumulative Wattage Start Date Name Name Object ID Description Syntax Access powerUsageCumulativeWattageStartDateName 1 3 6 1 4 1 674 10892 1 600 60 1 8 Defines the date and time at which the data collection started for the value reported by the powerUsageCumulative Wattage attribute DellDateName Read only Power Usage Peak Watts Object ID powerUsagePeakWatts 1 3 6 1 4 1 674 10892 1 600 60 1 9 176 Power Group Description Syntax Access powerUsagePeakWatts Defines the peak wattage reading in Watts for this entity since the date and time specified by the powerUsagePeakWattsStartDateName attribute DellUnsigned32BitRange Read only Power Usage Peak Watts Start Date Name Name Object ID Description Syntax Access powerUsagePeakWattsStartDateName 1 3 6 1 4 1 674 10892 1 600 60 1 10 Defines the date and time at which the data collection started for the value reported by the powerUsagePeak Watts attribute DellDateName Read only Power Group 177 Power Usage Peak Watts Reading Date Name Name Object ID Description Syntax Access powerUsagePeakWattsReadingDateName 1 3 6 1 4 1 674 10892 1 600 60 1 11 Defines the date and time at which the value reported by the powerUsage
122. write Remote Dial Up PPP Dial In Maximum Connection Time out Name remoteDialUpPPPDialInMaxConnectTimeout Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 9 Description Defines the PPP connect time out value in seconds for this remote access dial up functionality Syntax DellUnsigned32BitRange Access Read write 492 Remote Access Group Remote Dial Up Dial Out Modem Connect Time out Name remoteDialUpDialOutModemConnectTimeout Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 10 Description Defines the modem dial out time out value in seconds for this remote access dial up functionality Syntax DellUnsigned32BitRange Access Read write Remote Dial Up Modem Dial Type Name remoteDialUpModemDialType Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 11 Description Defines the dial type for the modem used by this remote access dial up functionality Syntax DellRemoteDialUpModemDialType SeeTable 19 24 Access Read write Remote Dial Up Modem Init String Name Name remoteDialUpModemInitStringName Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 12 Description Defines the initialization string to be sent to the modem for this remote access dial up functionality Syntax DisplayString SIZE 0 63 Access Read write Remote Dial Up Modem Baud Rate Name remoteDialUpModemBaudRate Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 13 Description Defines the baud rate for the modem used by this remote access dial up functionality Syntax DellUns
123. 0 110 10 Description This entry is obsolete Refer to 0001 softwareVersion Syntax DisplayString Access Read only Agent MIB Version Name agentMibVersion Object ID 1 3 6 1 4 1 674 10893 1 20 110 11 Description Identifies the version of the Storage Management MIB Syntax DisplayString Access Read only Storage Management Group 549 Agent Management Software URL Name Name agentManagement SoftwareURLName Object ID 1 3 6 1 4 1 674 10893 1 20 110 12 Description Identifies the Universal Resource Locator URL of the systems management software Syntax DisplayString Access Read only Agent Global System Status Name agentGlobalSystemStatus Object ID 1 3 6 1 4 1 674 10893 1 20 110 13 Description Global health information for the subsystem managed by the Storage Management software This global status should be used by applications other than HP OpenView HP OpenView should refer to the globalStatus in the root level object group This is a rollup for the entire agent including any monitored devices The status is intended to give initiative to an SNMP monitor to get further data when this status is abnormal Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 550 Storage Management Group Agent Last Global System Status Name Object ID Description Syntax Access agentLastGlobalSystemStatus 1 3 6 1 4 1 674 10893 1 20 110 14
124. 02 02 1 3 6 1 4 1 674 10892 1 200 10 1 9 1 3 1 3 6 1 4 1 674 10892 1 200 10 1 10 1 03 03 1 3 6 1 4 1 674 10892 1 200 10 1 11 1 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 1 3 6 1 4 1 674 10892 1 200 10 1 12 1 3 1 3 6 1 4 1 674 10892 1 200 10 1 13 1 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 1 3 6 1 4 1 674 10892 1 200 10 1 20 1 02 02 02 02 02 1 43 6 1 451 674 10892 1 200 10 1 21 1 3 1 3 6 1 4 1 674 10892 1 200 10 1 22 1 03 03 03 03 03 1 3 6 1 4 1 674 10892 1 200 10 1 23 1 02 02 02 02 02 02 750 SNMP Sample Output 13 3365 13 1 S375 LE 15 36 01 13 5624 e A 03 03 1 3 6 1 L336 duc WO Ww Ww U U U U U UU Ww 6 6 6 6 6 Sond 6 6 6 6 6 S Chassis RRES AR cist he Sis Oud 2650 3 33651 1 3 6 1 L305 dee 4 4 4 02 02 0 4 4 l Arar 4 1 1 674 4 1 674 03 03 03 03 03 03 1 674 2 02 1 674 1 674 03 03 4 1 674 674 674 674 674 OTA 1 674 674 674 674 674 674 674 674 674 674 674 674 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 10892 1 108921 10892 1 10892 1 200 1 200 1 200 1 200 1
125. 0892 1 1100 40 1 2 Defines the index of the cache device in this chassis DellObjectRange Read only Cache Device State Capabilities Name Object ID Description Syntax Access 276 cacheDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 40 1 3 Defines the capabilities of the cache device DellStateCapabilities Read only Device Group Cache Device State Settings Name Object ID Description Syntax Access cacheDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 40 1 4 Defines the state of the cache device DellStateSettings Read write Cache Device Status Name Object ID Description Syntax Access cacheDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 40 1 5 Defines the status of the cache device DellStatus Read only Cache Device Processor Device Index Reference Name Object ID Description cacheDeviceprocessorDevicelIndexReferenc 1 3 6 1 4 1 674 10892 1 1100 40 1 6 Defines the index number of the processor device with which this cache device is associated Syntax DellObjectRange Access Read only Cache Device Type Name cacheDeviceType Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 7 Description Defines the type of cache device Syntax DellCacheDeviceType See Table 13 7 Access Read only Device Group 277 Cache Device Location Name Object ID Description Syntax Access cacheDeviceLocation 1 3 6 1 4 1 674 10892 1 1100 40 1 8 Defines the location of the cache device
126. 0893 1 20 130 4 Description Defines the array disk table Syntax SEQUENCE OF ArrayDiskEntry Access Not accessible Array Disk Entry Name arrayDiskEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 Description Defines the array disk table entry Syntax ArrayDiskEntry Access Not accessible Index arrayDiskNumber Array Disk Number Name arrayDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 1 Description Identifies the instance number of the array disk entry Syntax Integer Access Read only Storage Management Group 585 Array Disk Name Name arrayDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 2 Description Identifies the name of the array disk as represented in Storage Management Syntax DisplayString Access Read only Array Disk Vendor Name arrayDiskVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 3 Description The array disk s manufacturer s name Syntax DisplayString Access Read only 586 Storage Management Group Array Disk State Name Object ID Description Syntax Access arrayDiskState 1 3 6 1 4 1 674 10893 1 20 130 4 1 4 Identifies the current state of the array disk Possible states 0 Unknown 1 Ready Available for use but no RAID configuration has been assigned 2 Failed Not operational 3 Online Operational RAID configuration has been assigned 4 Offline The drive is not available to the RAID controller 6 Degraded Refers to a fault tolerant array virtu
127. 0893 1 20 130 4 1 8 Description Identifies the firmware version of the array disk Syntax DisplayString Access Read only 588 Storage Management Group Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 9 Description Identifies the SCSI ID of the enclosure processor to which this array disk belongs Syntax DisplayString Access Read only Array Disk Channel Name arrayDiskChannel Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 10 Description Identifies the bus to which this array disk is connected Syntax Integer Access Read only Array Disk Length in Megabytes Name arrayDiskLengthInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 11 Description Identifies the size in megabytes of the array disk If this size is 0 it is smaller than a megabyte Syntax Integer Access Read only Array Disk Length in Bytes Name arrayDiskLengthInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 12 Description Identifies the size of the array disk in bytes that is less than a megabyte This size plus the arrayDiskLengthInMB is the total size of the array disk Syntax Integer Access Read only Storage Management Group 589 Array Disk Largest Contiguous Free Space in Megabytes Name arrayDiskLargestContiguousFreeSpaceInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 13 Description The size in megabytes of the largest contiguous free space on the array disk If this size is 0
128. 1 12 Description Defines characteristics of the system BIOS This attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit 63 is the first bit in the value and bit 0 is the last bit in the value See the description of DellUnsigned64BitRange at the beginning of this file for more information on the format of the value Bits 48 63 need to be examined in the context of the system ID The system ID is available in the attribute chassisID If the value for chassisID is non zero bits 8 63 have the meaning defined below Bit Position Meaning if Set Bit OReserved Bit 1Reserved Bit 2Unknown Bit 3BIOS Characteristics Not Supported Bit 4ISA is supported Bit 5MCA is supported Bit 6EISA is supported Bit 7PCI is supported Bit 8PC Card PCMCIA is supported Bit 9Plug and Play is supported Bit 10APM is supported Bit 11BIOS is Upgradeable Flash Bit 12BIOS shadowing is allowed Bit 13VL VESA is supported Bit 14ESCD support is available Bit 15Boot from CD is supported 94 l Chassis Information Group Description Syntax systemBIOSCharacteristics Bit Position Meaning if Set Bit 16Selectable Boot is supported Bit 17BIOS ROM is socketed Bit 18Boot From PC Card PCMCIA is supported Bit 19EDD Enhanced Disk Drive Specification is supported Bit 20Int 13h Japanese Floppy for NEC 9800 1 2mb 3 5 in 1k Bytes Sector 360 RPM is supported Bit 21 Int 13h Japanese Floppy for Toshiba 1 2mb 3
129. 1 1400 70 1 Defines the Diskette Control Table entry DellStatus Not accessible disketteControlchassisIndex disketteControlIndex Diskette Control Chassis Index Name Object ID Description Syntax Access disketteControlchassisIndex 1 3 6 1 4 1 674 10892 1 1400 70 1 1 Defines the index one based of this chassis DellObjectRange Read only Diskette Control Index Name Object ID Description Syntax Access disketteControlIndex 1 3 6 1 4 1 674 10892 1 1400 70 1 2 Defines the index of the diskette controllers in this chassis DellObjectRange Read only Diskette Control Capabilities Unique Name Object ID Description Syntax Access disketteControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1400 70 1 3 Defines the capabilities of the diskette controller DellDisketteControlCapabilitiesUnique See Table 16 18 Read only BIOS Setup Control Group 405 Diskette Control Settings Unique Name disketteControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 70 1 4 Description Defines the control settings for the diskette controller Syntax DellDisketteControlSettingsUnique Access Read only Diskette Control Status Name disketteControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 70 1 5 Description Defines the status of the diskette controller Syntax DellStatus Access Read only Diskette Control Name Name disketteControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 70 1 6 Description Def
130. 1 3 Description Defines the state of the operating system Syntax DellStateSettings Access Read write Operating System Status Name operatingSystemStatus Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 4 Description Defines the status of the operating system Syntax DellStatus Access Read only 122 Operating System Group Operating System Is Primary Name operatingSystemIsPrimary Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 5 Description Specifies whether this operating system is the primary operating system Syntax DellBoolean Access Read only Operating System Name Name operatingSystemOperatingSystemName Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 6 Description Defines the name of the operating system running on the system Syntax DisplayString SIZE 0 255 Access Read only Operating System Version Name Name operatingSystemOperatingSystemVersionName Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 7 Description Defines the version of the operating system running on the system Syntax DisplayString SIZE 0 255 Access Read only Operating System Memory Table Name operatingSystemMemoryTable Object ID 1 3 6 1 4 1 674 10892 1 400 20 Description Defines the Operating System Memory Table Syntax SEQUENCE OF OperatingSystemMemoryTableEntry Access Not accessible Operating System Group 123 Operating System Memory Table Entry Name operatingSystemTableEntry Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 Descr
131. 1 3 6 1 4 1 674 10892 1 1600 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only COO Service Contract Index Name cooServiceContract Index Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 2 Description Defines the index one based of this service contract Syntax DellObjectRange Access Read only 438 Cost of Ownership Group COO Service Contract State Name cooServiceContractState Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 3 Description Defines the status of the service contract for this system Syntax DellStateSettings Access Read only COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 4 Description Specifies whether the service contract for this system was renewed Syntax DellBoolean Access Read write COO Service Contract Type Name Name cooServiceContractTypeName Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 5 Description Defines the name of the service contract type for this system Syntax DellCostofOwnershipString Access Read write COO Service Contract Vendor Name Name cooServiceContractVendorName Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 6 Description Defines the name of the service contract provider for this system Syntax DellCostofOwnershipString Access Read write Cost of Ownership Group 439 COO Cost Event Log Table The COO Cost Event Log Table provides MIB objects that al
132. 1 674 10893 1 20 140 1 1 5 Description This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Syntax Integer Access Read only Virtual Disk Length in Megabytes Name virtualDiskLengthInMB Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 6 Description Identifies the size of this virtual disk in megabytes If this size is 0 it is smaller than a megabyte Syntax Integer Access Read only Virtual Disk Length in Bytes Name virtualDiskLengthBytes Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 7 Description Identifies the portion of the virtual disk in bytes that is smaller than a megabyte This size plus the virtualDiskLengthInMB is the total size of the virtual disk Syntax Integer Access Read only 644 Storage Management Group Virtual Disk Free Space in Megabytes Name virtualDiskFreeSpaceInMB Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 8 Description This entry is obsolete This property is not supported by virtual disks managed under Storage Management Syntax Integer Access Read only Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 9 Description This entry is obsolete This property is not supported by virtual disks managed under Storage Management Syntax Integer Access Read only Virtual Disk Write Policy Name virtualDiskWritePolicy Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 10
133. 1 Over Temperature Problem Upper Critical Critical going high 65929 Over Temperature Problem Cleared Informational 131328 Under Voltage Warning Lower Non Warning Critical going low 131456 Under Voltage Warning Cleared Informational 131330 Under Voltage Problem Lower Critical Critical going low 131458 Under Voltage Problem Cleared Informational 131335 Over Voltage Warning Upper Non Warning Critical going high 131463 Over Voltage Warning Cleared Informational 131337 Over Voltage Problem Upper Critical Critical going high 131465 Over Voltage Problem Cleared Informational 131841 Generic Critical Voltage Problem Critical 131840 Generic Critical Voltage Problem Informational Cleared 356096 Chassis Intrusion Physical Security Critical Violation 356224 Chassis Intrusion Physical Security Informational Violation Event Cleared 732 Traps Table 26 20 BMC Traps continued TrapID Description Severity 262400 Generic Predictive Fan Failure Minor predictive failure asserted 262528 Generic Predictive Fan Failure Cleared Informational 262402 Generic Critical Fan Failure Critical 262530 Generic Critical Fan Failure Cleared Informational 264962 Fan redundancy has been degraded Warning 264961 Fan Redundancy Lost Critical 264960 Fan redundancy Has Returned to Normal Informational 2715392 Battery Low Pre
134. 10892 2 3 2 8 Defines the temperature sensor health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsCMCPrevStatus Name DRsCMCPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 9 Description Syntax DellStatus Access Read only DRsGlobalChangeTime Name DRsGlobalChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 1 Description Defines the timestamp of the most recent global status change Syntax TimeTicks Access Read only DRslOMChangeTime Name DRsIOMChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 2 Description Syntax Access Defines the CMC health status being monitored by the chassis management card Defines the timestamp of the most recent IOM status change TimeTicks Read only Dell RAC Out of Band Group 677 DRsKVMChangeTime Name DRsKVMChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 3 Description Defines the timestamp of the most recent iKVM status change Syntax TimeTicks Access Read only DRsRedChangeTime Name DRsRedChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 4 Description Defines the timestamp of the most recent Redundancy status change Syntax TimeTicks Access Read only DRsPowerChangeTime Name DRsPowerChangeTime Object ID 1 3 6 1 4 1 674 10892 2 3 3 5 Description Defines the timestamp of the most recent power health status change Syntax TimeTicks Access Read only DRsFanChangeTime Name DRsFanChangeTime Object ID 1 3 6 1 4 1
135. 2 1 1400 10 1 4 Description Defines the status of the pointing device Syntax DellStatus Access Read only BIOS Setup Control Pointing Device Control Name Name bSUCpointingDeviceControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 5 Description Defines the setup BIOS name of the pointing device Syntax DellString Access Read only BIOS Setup Control Numeric Lock Control Capabilities Name bSUCnumLockControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 6 Description Defines the capabilities of the numeric lock Syntax DellStateCapabilities Access Read only BIOS Setup Control Numeric Lock Control Settings Name bSUCnumLockControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 7 Description Defines the state of the numeric lock Syntax DellStateSettings Access Read only BIOS Setup Control Group 385 BIOS Setup Control Numeric Lock Control Status Name bSUCnumLockControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 8 Description Defines the status of the numeric lock Syntax DellStatus Access Read only BIOS Setup Control Numeric Lock Control Name Name bSUCnumLockControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 9 Description Defines the setup BIOS name of the numeric lock Syntax DellString Access Read only BIOS Setup Control Processor Serial Number Control Capabilities Name bSUCprocessorSerialNumberControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 10 Description Def
136. 24 Access Read only POST Log Format Name post LogFormat Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 5 Description Defines format of the POST log Syntax DellLogFormat See Table 5 1 Access Read only Event Log Table Name event LogTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 40 Description Defines the Event Log Table Syntax SEQUENCE OF EventLogTableEntry Access Not accessible Event Log Table Entry Name eventLogTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 Description Defines the event Log Table Entry Syntax EventLogTableEntry Access Not accessible Index eventLogchassisIndex eventLogRecordIndex 88 Chassis Information Group Event Log Chassis Index Name Object ID Description Syntax Access event LogchassisIndex 1 3 6 1 4 1 674 10892 1 300 40 1 1 Defines the index one based of this chassis DellObjectRange Read only Event Log Record Index Name Object ID Description Syntax Access event LogRecordIndex 1 3 6 1 4 1 674 10892 1 300 40 1 2 Defines the record index of the event log DellUnsigned32BitRange Read only Event Log State Capabilities Unique Name Object ID Description Syntax Access eventLogStateCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 300 40 1 3 Defines the capabilities of the object that is writing the event log DellStateCapabilitiesLogUnique Read only Event Log State Settings Unique Name Object ID Description Syntax Access eventLogSta
137. 2BitRange Read only Network Device Teaming Flags Name Object ID Description Syntax Access networkDeviceTeamingFlags 1 3 6 1 4 1 674 10892 1 1100 90 1 22 Defines the teaming features of the network device DellNetworkDeviceTeamingFlags see Table 13 21 Read only Network Device TOE Capability Flags Name Object ID Description Syntax Access networkDeviceTOECapabilityFlags 1 3 6 1 4 1 674 10892 1 1100 90 1 23 Defines the TCP IP Offload Engine TOE capability flags of the network device DellNetworkDeviceTOECapabilityFlags see Table 13 22 Read only Network Device TOE Enabled Name Object ID Description Syntax Access networkDeviceTOEEnabled 1 3 6 1 4 1 674 10892 1 1100 90 1 24 Defines if TOE is enabled for the network device DellBoolean Read only Device Group 307 Network Device RDMA Capability Flags Name Object ID Description Syntax Access networkDeviceRDMACapabilityFlags 1 3 6 1 4 1 674 10892 1 1100 90 1 25 Defines the Remote Direct Memory Access RDMA capability flags of the network device DellNetworkDeviceRDMACapabilityFlags see Table 13 23 Read only Network Device RDMA Enabled Name Object ID Description Syntax Access networkDeviceRDMAEnabled 1 3 6 1 4 1 674 10892 1 1100 90 1 26 Defines if RDMA is enabled for the network device DellBoolean Read only Network Device iSCSI Capability Flags Name Object ID Desc
138. 3 BIOS Setup Control Group 383 variable values 409 c Change 657 Change Management Group 657 Chassis Information Group tables 71 Chassis Information Table 71 Event Log Table 88 Firmware Table 97 Intrusion Table 100 102 POST Log Table 86 System BIOS Table 91 UUID Table 84 Variable Values 107 Cluster Group 517 Cluster Table 517 variable values 520 Cost of Ownership Group COO Cost Event Log Table 440 COO Lease Information Table 444 COO Maintenance Table 450 COO Options Table 448 COO Repair Table 452 Index 755 COO Schedule Number Table 447 COO Service Contract Table 438 COO Support Information Table 454 COO Trouble Ticket Table 456 COO Warranty Table 42 Cost of Ownership Table 427 Cost of Ownership tables 427 data types common 743 state capabilities 744 state settings 745 status 746 status probe 747 status redundancy 746 Dell RAC Out of Band Group 667 Chassis Alerts 687 Chassis Power 680 Chassis Status 671 CMC Power Information 681 CMC PSU Information 685 Legacy Alerting 689 Product Information 667 Device added to system 721 Device configuration error detected 722 Device Group 658 Cache Device Table 275 Index Generic Device Table 292 Keyboard Device Table 262 Memory Device Mapped Address Table 289 Memory Device Table 281 PCI Device Configuration Space Table 298 PCI Device Table 295 Pointing Device Table 260 Pro
139. 300 10 1 6 Defines the chassis type DellChassisType See Table 5 2 Read only chassisName 1 3 6 1 4 1 674 10892 1 300 10 1 7 Defines the user assigned chassis name of the chassis DellString Read write Chassis Information Group 73 Chassis Manufacturer Name Name chassisManufacturerName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 8 Description Defines the manufacturer s name for this chassis Syntax DellString Access Read only Chassis Model Name Name chassisModelName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 9 Description Defines the system model type for this chassis Syntax DellString Access Read only Chassis Asset Tag Name Name chassisAssetTagName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 10 Description Defines the user assigned asset tag name for this chassis Syntax DisplayString SIZE 0 10 Access Read write Chassis Service Tag Name Name chassisServiceTagName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 11 Description Defines the service tag name for this chassis Syntax DisplayString SIZE 0 7 Access Read only 74 Chassis Information Group Chassis ID Name Object ID Description Syntax Access chassisID 1 3 6 1 4 1 674 10892 1 300 10 1 12 Defines the asset tag name for this chassis DellUnsigned8BitRange Read only Chassis ID Extension Name Object ID Description Syntax Access chassisIDExtension 1 3 6 1 4 1 674 10892 1 300 10 1 13 Defines the SMBIOS
140. 4 10892 1 lt MIB group number gt where 26 Introduction lt MIB group number gt is the MIB group number assigned to the MIB group See the relevant section for more information about the MIB objects defined in a MIB group Table 1 4 Server Administrator Field Replaceable Unit MIB Sections in This Guide Section Topic MIB Group Numbers 22 Field Replaceable Unit Group provides information about 2000 field replaceable units that may be present in your system Server Administrator Storage Management MIB The Server Administrator Storage Management MIB filename destorag mib provides storage management data that allows you to monitor the health of storage resources with SNMP management applications Table 1 5 describes each Server Administrator Storage Management MIB group and lists the MIB group number assigned to the MIB group The Server Administrator Storage Management MIB groups are identified by the SNMP OID 1 3 6 1 4 1 674 lt MIB group number gt where lt MIB group number gt is the MIB group number assigned to the MIB group See the relevant section for more information about the MIB objects defined in a MIB group Table 1 5 Server Administrator Storage Management MIB Sections in This Guide Section Topics MIB Group Numbers 23 Storage Management Group consists of definitions for the 10893 following MIB groups e Storage Management Group e Storage Management Information Group e Global Data Grou
141. 4 10892 1 1700 10 1 26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read write 474 Remote Access Group Remote Access NIC Static Gateway Address Name Object ID Description Syntax Access remoteAccessNICStaticGatewayAddress 1 3 6 1 4 1 674 10892 1 1700 10 1 27 Defines the IP address for the gateway associated with the static IP address to be used by the integrated NIC provided by the remote access hardware IpAddress Read write Remote Access Personal Computer Memory Card International Association PCMCIA Info Name Name Object ID Description Syntax Access remoteAccessPCMCIAInfoName 1 3 6 1 4 1 674 10892 1 1700 10 1 28 Defines the information for the PCMCIA device used by the remote access hardware DisplayString SIZE 0 63 Read only Remote Access Miscellaneous Information Name Name Object ID Description Syntax Access remoteAccessMiscInfoName 1 3 6 1 4 1 674 10892 1 1700 10 1 29 Defines the miscellaneous information for the remote access hardware DisplayString SIZE 0 63 Read write Remote Access Group 475 Remote Access NIC Current IP Address Name remoteAccessNICCurrent IPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware
142. 4 Power Supply Warning Cleared Informational 552707 Power Supply AC Lost Critical 552835 Power Supply AC Restored Informational 789249 emory Redundancy Has Been Lost Critical 789248 emory redundancy Has Returned to Informational Normal 1076994 System Event Log SEL Cleared Informational 734 Traps Table 26 20 BMC Traps continued TrapID Description Severity 1076996 System Event Log SEL Full Logging Critical Disabled 2322176 ASR Automatic System Recovery Timer Critical Expired 2322177 ASR Automatic System Recovery Reset Critical Occurred 2322178 ASR Automatic System Recovery Power Critical Down Occurred 2322179 ASR Automatic System Recovery Power Critical Cycle Occurred Traps 735 736 Traps Storage Management Alert Reference Storage Management s alert or event management features let you monitor the health of storage resources such as controllers connectors array disks and virtual disks Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging By default the Storage Management Service starts when the managed system starts up If you stop the Disk Management Service then alert monitoring and logging stops Alert monitoring does the following e Updates the status of the storage object that generated the alert e Propagates the storage object s status to all the related higher objects in the storage h
143. 400 80 1 3 Description Defines the capabilities of the NIC Syntax DellNetworkInterfaceControlCapabilitiesUnique See Table 16 19 Access Read only Network Interface Control Settings Unique Name networkInterfaceControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 80 1 4 Description Defines the control settings for the NIC Syntax DellNetworkInterfaceControlSettings Unique See Table 16 20 Access Read write Network Interface Control Status Name networkInterfaceControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 80 1 5 Description Defines the status of the NIC Syntax DellStatus Access Read only Network Interface Control Name Name networkInterfaceControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 80 1 6 Description Defines the setup BIOS name of the NIC Syntax DellString Access Read only 408 BIOS Setup Control Group BIOS Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 16 1 Speaker Control Capabilities Unique Variable Name De11SpeakerControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Speaker control capabilities are unknown enableCapable 2 Setup BIOS can enable speaker control lowCapable 4 Setup BIOS can set the speaker volume to low mediumCapable 8 Setup BIOS can set the speaker volume to medium high
144. 471 0000 uniquely identifies a single phone The phone number can be broken down into a number of components to uniquely identify a phone The first component 011 is the country code for the United States The second component 512 identifies the area code for central Texas The third component 471 is the phone exchange for a large state university in the city of Austin The final component 0000 is the main switchboard There are two main differences between the phone number example and an actual OID The first difference is that there are many more components in an OID up to 128 The combination of these components is called an OID prefix The second difference is that OIDs support the concept of indexes or keys The OID prefix specifies the data class but does not specify an instance of the data within the class Indexes can be used to identify the instances of a data class These indexes are referred to as the OID suffix The assignment of values for each OID prefix component can be illustrated by using a tree structure The following is an example of an OID assignment ROOT CCITT 0 ISO 1 ORG 3 DOD 6 INTERNET 1 MGMT 2 MIB 1 EXPERIMENTAL 3 PRIVATE 4 ENTERPRISES 1 DELL 674 SNMPy2 6 40 Introduction In the preceding example the OID prefix for the Dell enterprise would be 1 3 6 1 4 1 674 The numbers in boldface type show the categories and numbers that apply to Server Administrator All Server Administrat
145. 5 Defines the status of the cooling device DellStatusProbe Read only Thermal Group 201 Cooling Device Reading Name coolingDeviceReading Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 6 Description Defines either the cooling device s speed in revolutions per minute RPM or the off on value of the fan When the value for coolingDeviceSubType is other than coolingDeviceSubTypelsDiscrete the value returned for this attribute is the speed in RPM or the OFF ON value of the cooling device When the value for coolingDeviceSubType is coolingDeviceSubTypelsDiscrete a value is not returned for this attribute Syntax DellSigned32BitRange Access Read only Cooling Device Type Name coolingDeviceType Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 7 Description Defines the cooling device type Syntax DellCoolingDeviceType See Table 9 1 Access Read only Cooling Device Location Name Name Object ID Description Syntax Access 202 coolingDeviceLocationName 1 3 6 1 4 1 674 10892 1 700 12 1 8 Defines the location of the cooling device in this chassis DellString Read only Thermal Group Cooling Device Upper Nonrecoverable Threshold Name coolingDeviceUppernonrecoverableThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 9 Description Defines the value of the fan s upper nonrecoverable threshold Syntax DellSigned32BitRange Access Read only Cooling Device Upper Critical Threshold Name coolingDeviceUpperCriti
146. 6 1 4 1 674 10892 1 1600 50 Description Defines the COO Lease Information Table Syntax SEQUENCE OF CooLeaselnformationTableEntry Access Not accessible COO Lease Information Table Entry Name cooLeaseInformationTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 Description Defines the COO Lease Information Table entry Syntax CooLeaseInformationTableEntry Access Not accessible Index cooLeaselnformationchassisIndex cooLeaselnformationIndex COO Lease Information Chassis Index Name cooLeaseInformationchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only 444 Cost of Ownership Group COO Lease Information Index Name Object ID Description Syntax Access cooLeaseInformationIndex 1 3 6 1 4 1 674 10892 1 1600 50 1 2 Defines the index of the lease information for this system DellObjectRange Read only COO Lease Information State Name Object ID Description Syntax Access cooLeaseInformationState 1 3 6 1 4 1 674 10892 1 1600 50 1 3 Defines the lease information state for this system DellStateSettings Read write COO Lease Information Multiple Schedules Name Object ID Description Syntax Access cooLeaseInformationMultipleSchedules 1 3 6 1 4 1 674 10892 1 1600 50 1 4 Defines whether there are multiple schedules for this lease DellBoolean Read only COO Lease Information Buyout
147. 6 1 4 1 674 10892 1 1700 20 1 21 Description Defines the message to be sent to the alphanumeric pager to inform the user of a call by this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote User Admin Pager Alpha Modem Connect Time out Name remot eUserAdminPagerAlphaModemConnect Timeout Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 22 Description Defines the modem connection time out for the alphanumeric pager for this remote access user Syntax DellUnsigned32BitRange Access Read write Remote User Admin Pager Alpha Pager ID Name Name remot eUserAdminPagerAlphaPagerlIdName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 23 Description Defines the ID to be sent to the alphanumeric pager to inform the user of a call by this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote User Admin Pager Alpha Password Name Name remot eUserAdminPagerAlphaPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 24 Description Defines the password for the alphanumeric pager for this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote Access Group _ 483 Remote User Admin Pager Modem Init String Name Name remot eUserAdminPagerModemInitStringName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 25 Description Defines the initialization string to be sent to the pager modem for this remote access user Syntax DisplayString SIZE 0 31 Access Read wri
148. 6 2Plus 31 The processor family is K6 2 deviceFamilyIsPowerPC 32 The processor family is Power PC deviceFamilyIsPowerPC601 33 The processor family is Power PC 601 deviceFamilyIsPowerPC603 34 The processor family is Power PC 603 deviceFamilyIsPowerPC603Plus The processor family is Power PC 603 35 deviceFamilyIsPowerPC604 36 The processor family is Power PC 604 deviceFamilyIsPowerPC620 37 The processor family is Power PC 620 deviceFamilyIsPowerPCx704 38 The processor family is Power PC x704 deviceFamilyIsPowerPC750 39 The processor family is Power PC 750 deviceFamilyIsIntelCoreDuo 40 The processor family is Intel Core Duo deviceFamilyIsIntelCoreDuoMobi The processor family is Intel Core Duo le 41 mobile deviceFamilyIsIntelCoreSoloMob The processor family is Intel Core Solo ile 42 mobile deviceFamilyIsIntelAtom 43 The processor family is Intel Atom deviceFamilyIsAlpha 48 The processor family is Alpha deviceFamilyIsAlpha21064 49 The processor family is Alpha 21064 deviceFamilyIsAlpha21066 50 The processor family is Alpha 21066 deviceFamilyIsAlpha21164 51 The processor family is Alpha 21164 deviceFamilyIsAlpha21164PC 52 The processor family is Alpha 21164PC deviceFamilyIsAlpha21164a 53 The processor family is Alpha 21164a deviceFamilyIsAlpha21264 54 The processor family is Alpha 21264 Device Group 323 Tab
149. 60 1 7 Defines the IP address for this remote access dial out destination IpAddress Read write Remote Dial Out Phone Number Name Name Object ID Description Syntax Access remoteDialOutPhoneNumberName 1 3 6 1 4 1 674 10892 1 1700 60 1 8 Defines the phone number for this remote access dial out destination DisplayString SIZE 0 95 Read write Remote Dial Out PPP Username Name Object ID Description Syntax Access remoteDialOutPPPUserName 1 3 6 1 4 1 674 10892 1 1700 60 1 9 Defines the PPP username for this remote access dial out destination DisplayString SIZE 0 31 Read write Remote Access Group _ 499 Remote Dial Out PPP Password Name Name remoteDialOutPPPPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 10 Description Defines the PPP password for this remote access dial out destination Syntax DisplayString SIZE 0 31 Access Read write Remote Access Variable Values This section includes definitions for server administrator specific variable values used in this section Table 19 1 Remote Access Type Variable Name De 1 1RemoteAccessTyp Data Type Integer Possible Data Values Meaning of Data Value remoteAccessTypelsOther 1 The remote access type is not one of the following remoteAccessTypelIsUnknown 2 The remote access type is unknown remoteAccessTypeIsDRACIII 3 The remote access type is DRAC III remoteAc
150. 674 10892 1 1100 30 1 10 Defines the family of the processor device DellProcessorDeviceFamily See Table 13 6 Read only Device Group 267 Processor Device Maximum Speed Name processorDeviceMaximumSpeed Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 11 Description Defines the maximum speed of the processor device in megahertz MHz A zero 0 indicates that the speed is unknown Syntax DellUnsigned32BitRange Access Read only Processor Device Current Speed Name processorDeviceCurrent Speed Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 12 Description Defines the current speed of the processor device in MHz A zero 0 indicates that the speed is unknown Syntax DellUnsigned32BitRange Access Read only Processor Device External Clock Speed Name processorDeviceExternalClockSpeed Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 13 Description Defines the speed of the external clock the front side bus speed for the processor device in MHz A zero 0 indicates that the speed is unknown Syntax DellUnsigned32BitRange Access Read only 268 Device Group Processor Device Voltage Name processorDeviceVoltag Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 14 Description Defines the voltage powering the processor device in millivolts A zero 0 indicates the speed is unknown Syntax DellSigned32BitRange Access Read only Processor Device Upgrade Information Name processorDeviceUpgradeInformation Obje
151. 73 DRsTempCurrStatus 674 DRsCMCCurrStatus 674 DRsGlobalPrevStatus 674 DRslOMPrevStatus 675 DRsKVMPrevStatus 675 DRsRedPrevStatus 675 DRsPowerPrevStatus 676 DRsFanPrevStatus 676 DRsBladePrevStatus 676 DRsTempPrevStatus 677 DRsCMCPrevStatus 677 DRslOMChangeTime 677 DRsKVMChangeTime 678 DRsRedChangeTime 678 DRsPowerChangeTime 678 DRsFanChangeTime 678 DRsBladeChangeTime 679 DRsTempChangeTime 679 DRsCMCChangeTime 679 ChassisPower 680 DRsCMC Power Table 680 DRsCMC Power TableEntry 680 Contents 13 DRsCMC PSUTable 2 680 DRsCMC PSUTableEntry 681 CMC Power Information 681 DRsChassisIndex 04 681 DRsPotentialPower 681 DRsldlePower 2 682 DRsMaxPowerSpecification 682 DRsPowerSurplus 682 DRsKWhCumulative 683 DRsKWhCumulativeTime 683 DRsWattsPeakUsage 683 DRsWattsPeakTime 683 DRsWattsMinUsage 684 DRsWattsMinTime 684 DRsWattsResetlime 684 DRsWattsRe
152. 775 21 Upgrade is by Socket LGA775 processorUpgradeIsBySocketS1 22 Upgrade is by Socket S1 processorUpgradeIsBySocketAM2 23 Upgrade is by Socket AM2 processorUpgradeIsBySocketF 24 Upgrade is by Socket F 1207 processorUpgradeIsBySocketLGA1366 25 Upgrade is by Socket LGA1366 Table 13 6 Processor Device Family Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsOther 1 The processor family is not one of the following values deviceFamilyIsUnknown 2 The processor family is unknown deviceFamilyIs8086 3 he processor family is 8086 deviceFamilyIs80286 4 he processor family is 80286 deviceFamilyIs80486 6 he processor family is 80486 T T deviceFamilyIs80386 5 The processor family is 80386 T T deviceFamilyIS8087 7 he processor family is 8087 Device Group 321 Table 13 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIs80287 8 The processor family is 80287 deviceFamilyIs80387 9 The processor family is 80387 deviceFamilyIs80487 10 The processor family is 80487 deviceFamilyIsPentium 11 The processor family is Intel Pentium deviceFamilyIsPentiumPro 12 The processor family is Pentium Pro deviceFamilyIsPentium2 13
153. 893 1 20 130 15 1 12 Description Specifies the learn state activity of the battery Possible values 1 Failed 2 Active 4 Timed out 8 Requested 16 Idle Syntax Integer Access Read only Battery Maximum Learn Delay Name batteryMaxLearnDelay Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 14 Description The maximum amount of time in hours that the battery learn cycle can be delayed Syntax Integer Access Read only 638 Storage Management Group Battery Connection Table This table describes the connection between each controller battery on the managed system and its controller Each controller number in the table corresponds to that controller instance in the controller Table The following object sets up the Battery Connection Table Name Object ID Description Syntax Access batteryConnectionTable 1 3 6 1 4 1 674 10893 1 20 130 16 Defines the battery connection table SEQUENCE OF BatteryConnectionEntry Not accessible Battery Connection Entry Name Object ID Description Syntax Access Index batteryConnectionEntry 1 3 6 1 4 1 674 10893 1 20 130 16 1 Defines the battery connection table entry BatteryConnectionEntry BatteryConnectionEntry BatteryConnectionNumber Battery Connection Number Name Object ID Description Syntax Access batteryConnectionNumber 1 3 6 1 4 1 674 10893 1 20 130 16 1 1 Identifies the instance number of the battery connection entry Integer Read only
154. 893 1 20 130 2 1 5 Description Identifies the type of SCSI termination on this channel Termination is required for proper operation of this channel Possible values 1 Wide Termination 16 bit 2 Narrow Termination 8 bit 3 Not Terminated Syntax Integer Access Read only Channel SCSI ID Name channelSCSIID Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 6 Description Identifies the SCSI ID of the controller to which the channel belongs Syntax Integer Access Read only 572 Storage Management Group Channel Roll Up Status Name Object ID Description Syntax Access channelRollUpStatus 1 3 6 1 4 1 674 10893 1 20 130 2 1 7 Identifies the severity of the channel state This is the combined status of the channel and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Channel Component Status Name Object ID Description Syntax Access channelComponentStatus 1 3 6 1 4 1 674 10893 1 20 130 2 1 8 The status of the channel itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Storage Management Group 573 Channel Nexus ID Name channelNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 9 Description Durable unique ID for this channel Syntax DisplayString Access Read only
155. 92 1 1900 20 1 3 Description Defines the index one based of the BMC serial interface Syntax DellObjectRange Access Read only 526 Baseboard Management Controller Group BMC Serial Interface State Capabilities Name Object ID Description Syntax Access bmcSerialInterfaceStateCapabilities 1 3 6 1 4 1 674 10892 1 1900 20 1 4 Defines the state capabilities of the BMC serial interface DellStateCapabilities Read only BMC Serial Interface State Settings Name Object ID Description Syntax Access bmcSerialInterfaceStateSettings 1 3 6 1 4 1 674 10892 1 1900 20 1 5 Defines the state settings of the BMC serial interface DellStateSettings Read write BMC Serial Interface Status Name Object ID Description Syntax Access bmcSerialInterfaceStatus 1 3 6 1 4 1 674 10892 1 1900 20 1 6 Defines the status of the BMC serial interface DellStatus Read only BMC Serial Interface Channel Number Name Object ID Description Syntax Access bmcSerialInterfaceChannelNumber 1 3 6 1 4 1 674 10892 1 1900 20 1 7 Defines the BMC channel number of the BMC serial interface DellUnsigned8BitRange Read only Baseboard Management Controller Group 527 BMC Serial Interface Connection Mode Capabilities Name bmcSerialInterfaceConnectionModeCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 8 Description Defines the connection mode capabilities of the BMC serial interface Syntax DellBMCSerialConnect
156. Amount Name Object ID Description Syntax Access cooLeaseInformationBuyOutAmount 1 3 6 1 4 1 674 10892 1 1600 50 1 5 Defines the balance purchase price for this system DellUnsigned32BitRange Read write Cost of Ownership Group 445 COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 6 Description Defines the rate factor for the lease on this system Syntax DellUnsigned32BitRange Access Read write COO Lease Information End Date Name Name cooLeaseInformat ionEndDateName Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 7 Description Defines the end date for the lease on this system Syntax DellDateName Access Read write COO Lease Information Fair Market Value Name cooLeaseInformationFairMarketValue Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 8 Description Defines the fair market value of this system Syntax DellUnsigned32BitRange Access Read write COO Lease Information Lessor Name Name cooLeaseInformationLessorName Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 9 Description Defines the name of the lessor of this system Syntax DellCostofOwnershipString Access Read write 446 Cost of Ownership Group COO Schedule Number Table Name Object ID Description Syntax Access cooScheduleNumberTabl 1 3 6 1 4 1 674 10892 1 1600 60 Defines the COO Schedule Number Information Table SEQUENCE OF CooScheduleNumberTableEntry Not acces
157. B Version Group the Systems Management Software Group the System State Group the Chassis Information Table and Event Log Table The data is from a Dell PowerEdge 2650 system Walk 1 3 6 1 4 1 674 10892 Community public iso org dod internet privat Agent SERVERO1 3 6 1 4 1 674 10892 1 1 1 0 1 3 6 1 4 1 674 10892 1 1 2 0 3 6 1 4 1 674 10892 1 1 3 0 1 3 6 1 4 1 674 10892 1 100 1 Administrator 1 3 6 1 4 1 674 10892 1 100 2 1 3 6 1 4 1 674 10892 1 100 3 1 3 6 1 4 1 674 10892 1 100 4 software for Dell systems 1 3 6 1 4 1 674 10892 1 100 5 L 3 6 1 4 1 674 10892 1 100 6 1 3 6 1 4 1 674 10892 1 100 7 1 3 6 1 4 1 674 10892 1 100 8 https 1 2 3 4 1311 1 3 6 1 4 1 674 10892 1 100 9 nterprises dell server3 5 3 0 0 Server 0 543 0 O 4522 0 Management 0 1 Oo 1 0 No Updates Oo 0 en_US SNMP Sample Output 749 Li3v6e1 450 674 10892 1 100610 0 222 0 1 3 6 1 4 1 674 10892 1 100 11 0 0 1 3 6 1 4 1 674 10892 1 100 12 0 lt 21 1 3 6 1 4 1 674 10892 1 100 13 0 Dell Inc 1 3 6 1 4 1 674 10892 1 200 10 1 1 1 1 1 3 6 1 4 1 674 10892 1 200 10 1 2 1 3 1 3 641 401 674 10892 1 200 10 163 1 2 1 3 6 1 4 1 674 10892 1 200 10 1 4 3 1 3 6 1 4 1 674 10892 1 200 10 1 5 1 02 1 3 6 1 4 1 674 10892 1 200 10 1 6 1 3 1 3 6 1 4 1 674 10892 1 200 10 1 7 1 03 1 3 6 1 4 1 674 10892 1 200 10 1 8 1
158. C will use DHCP to obtain an IP address Table 19 8 Remote Access Host Capabilities Variable Name De 1 1RemoteAccessHostCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no host capabilities unknownCapabilities 1 The remote access hardware host capabilities are unknown smtpEmailCapable 2 The remote access hardware supports sending e mail using SMTP tftpRemoteFloppyCapable 4 The remote access hardware supports remote floppy boot using a TFTP server tfitpRemoteFwUpdateCapable 8 The remote access hardware supports remote firmware update using a TFTP server 504 Remote Access Group Table 19 9 Remote Access Host Settings Variable Name Del 1RemoteAccessHostSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no host settings unknown 1 The remote access hardware host settings are unknown smtpEmailEnabled 2 The remote access hardware SMTP client is enabled for sending e mail tftpRemoteFloppyEnabled 4 The remote access hardware TFTP client is enabled for remote floppy boot tftpRemoteFwUpdateEnabled 8 The remote access hardware TF TP client is enabled for remote firmware update Table 19 10 Remote Access Out Of Band Simple Network Management Protocol SNMP Capabilities Variable N
159. CIM Systems Management Software Group _ _i 49 50 Table 3 2 Systems Management Software Feature Flags Variable Name SMSFeatureFlags Data Type Integer Possible Data Values Meaning of Data Value none 0 The Systems Management Software features are not enabled webOneToOneManagementPreferred 1 The web 1 1 management preferred feature is enabled Table 3 3 Systems Management Software SNMP Agent Feature Flags Variable Name SMSSNMPAgentFeatureFlags Data Type Integer Possible Data Values Meaning of Data Value none 0 The Systems Management Software SNMP agent features are not enabled supportsSparseTables 1 The SNMP agent supports sparse tables Systems Management Software Group System State Group The Management Information Base MIB variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system Components monitored under the System State Group include power supplies AC power cords AC power switches and cooling devices as well as temperature fan amperage and voltage probes System State Group Table The System State Group defines objects in the System State MIB table System State Table The following object sets up the System State Table Name systemStateTable Object ID 1 3 6 1 4 1 674 10892 1 200 10 Description Defines the System State Table Syntax SEQUENCE O
160. Capabilities Name Object ID Description Syntax Access bSUCtpmSecurityControlCapabilities 1 3 6 1 4 1 674 10892 1 1400 10 1 36 Defines the BIOS setup control capabilities of Trusted Platform Module TPM security DellTPMSecurityControlCapabilities Read only BIOS Setup Control TPM Security Control Setting Name Object ID Description Syntax Access bSUCtpmSecurityControlSetting 1 3 6 1 4 1 674 10892 1 1400 10 1 37 Defines the BIOS setup control setting of Trusted Platform Module TPM security DellTPMSecurityControlSetting Read only BIOS Setup Control TPM Security Control Status Name Object ID Description Syntax Access bSUCtpmSecurityControlStatus 1 3 6 1 4 1 674 10892 1 1400 10 1 38 Defines the BIOS setup control status of Trusted Platform Module TPM security DellStatus Read only BIOS Setup Control TPM Security Control Name Name Object ID Description Syntax Access bSUCtpmSecurityControlName 1 3 6 1 4 1 674 10892 1 1400 10 1 39 Defines the BIOS setup control name of Trusted Platform Module TPM security DellString Read only BIOS Setup Control Group 393 SCSI Control Table Name sCSIControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 20 Description Defines the Small Computer System Interface SCSI Control Table Syntax SCSIControlTableEntry Access Not accessible SCSI Control Table Entry Name sCSIControlTableEntry Object ID 1 3 6 1 4
161. Capable 16 Setup BIOS can set the speaker volume to high allVolumeCapable 30 Setup BIOS can set the speaker volume to any of the three settings Table 16 2 Speaker Control Settings Unique Variable Name De11SpeakerControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Speaker control state is unknown enabled 2 Speaker control is enabled low 4 Speaker control volume is low medium 8 Speaker control volume is medium high 16 Speaker control volume is high BIOS Setup Control Group 409 Table 16 3 Network Interface NIF Wakeup on LAN Capabilities Unique Variable Name De 1 1NIFwakeonLanControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Setup BIOS Wakeup on LAN capabilities are unknown enableCapable 2 Setup BIOS is capable of enabling the NIF Wakeup on LAN addInCardCapable 4 Setup BIOS is capable of enabling Wakeup on LAN by option card onBoardCapable 8 Setup BIOS is capable of enabling Wakeup on LAN by integrated NIF bothCapable 14 Setup BIOS is capable of enabling Wakeup on LAN by either option card or integrated NIE Table 16 4 NIF Wakeup on LAN Control Settings Unique Variable Name De 1 1NIFwakeonLanControlSettingsUnique Data Type Integer Possible Data Values Meaning of Da
162. Connectorlype Access Read only Memory Device Port Physical Memory Array Index Reference Name memoryDevicePortPhysicalMemoryArrayIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 10 Description Defines the index to the associated physical memory array Syntax DellUnsigned32BitRange Access Read only 236 Port Group Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 11 Description Defines the index one based of the Physical Memory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with if any Syntax DellUnsigned32BitRange Access Read only Monitor Port Table Name monitorPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 50 Description Defines the Monitor Port Table Syntax IntegerMonitorPortTableEntry Access Not accessible Monitor Port Table Entry Name monitorPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 Description Defines the Monitor Port Table entry Syntax MonitorPortTableEntry Access Not accessible Index monitorPortchassisIndex monitorPortIndex Monitor Port Chassis Index Name monitorPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only PortGroup 237 Monitor Port Index Name monitorPort Index
163. D Card Unit table e sdCardUnitTable e sdCardUnitTableEntry e sdCardUnitChassisIndex e sdCardUnitIndex e sdCardUnitStateCapabilities e sdCardUnitStateSettings e sdCardUnitRedundancyStatus e sdCardUnitCountForRedundancy e sdCardUnitName e sdCardUnitStatus e Added the following MIB objects to the SD Card Device table sdCardDeviceTable sdCardDeviceTableEntry e sdCardDeviceChassisIndex sdCardDevicelndex e sdCardDeviceStatus e sdCardDeviceType e sdCardDeviceConfigCapabilities e sdCardDeviceConfigSettings sdCardDeviceLocationName e sdCardDeviceCardPresent e sdCardDeviceCardState e sdCardDeviceCardStorageSize e sdCardDeviceUnitIndexReference e Added the following enumerations to the SD Card Device table e DellSDCardDevicelype 20 Introduction DellSDCardDeviceConfigCapabilities DellSDCardDeviceConfigSettings DellSDCardDeviceCardState What s New in Traps Added the following instrumentation trap alertSDCardDeviceFailure 1754 What s New in Power Group Added the following MIB object to the Power Supply table powerSupplyRatedInput Wattage Added the following MIB objects to the Power Usage table powerU powerl powerl powerU powerU powerl powerU sageldlePower sageMaxPotentialPower sagePowerCapCapabilities sage PowerCapSetting sagePowerCapValue sagelnstantaneousHeadroom sagePeakHeadroom Added the following MIB objects to the Powe
164. D 1 3 6 1 4 1 674 10892 1 1700 20 1 31 Description Defines the type of user for this remote access user Syntax DellUnsigned8BitRange Access Read write Remote SNMP Trap Table Name remoteSNMPTrapTable Object ID 1 3 6 1 4 1 674 10892 1 1700 30 Description Defines the Remote Access SNMP Trap Destination Table Syntax SEQUENCE OF RemoteSNMP1TrapTableEntry Access Not accessible Remote Access Group _ 485 Remote SNMP Trap Table Entry Name remoteSNMPTrapTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 Description Defines the Remote Access SNMP Trap Destination Table entry Syntax RemoteSNMP Trap TableEntry Access Not accessible Index remoteSNMPTrapChassisIndex remoteSNMPTrapAdapterIndex remoteSNMPTrapIndex Remote SNMP Trap Chassis Index Name remoteSNMPTrapChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellObjectRange Access Read only Remote SNMP Trap Adapter Index Name remoteSNMPTrapAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 2 Description Defines the index one based of the remote access hardware that uses this SNMP trap destination Syntax DellObjectRange Access Read only 486 Remote Access Group Remote SNMP Trap Index Name remoteSNMPTrapIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 3 Description Defines the index one based of this remote access SNMP trap de
165. D 1 3 6 1 4 1 674 10892 1 200 10 1 32 Description Defines the individual state of all AC power switches in this chassis The first byte returned represents the state of the first AC power switch the second byte returned represents the state of the second AC power switch and so on Syntax OCTET STRING SIZE 1 128 Access Read only System State AC Power Switch Status Redundancy Name systemStateACPowerSwitchStatusRedundancy Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 33 Description Defines the overall redundancy status of the AC power switches in this chassis Syntax DellStatusRedundancy Access Read only System State AC Power Switch Status Details Name systemStateACPowerSwitchStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 34 Description Defines the individual status of all AC power switches in this chassis The first byte returned represents the status of the first AC power switch the second byte returned represents the status of the second AC power switch and so on Syntax OCTET STRING SIZE 1 128 Access Read only 62 System State Group System State AC Power Cord State Details Name systemStateACPowerCordStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 35 Description Defines the individual state of all AC power cords for any AC power switches in this chassis The first byte returned represents the state of the first AC power cord the second byte returned represents the state of the second AC p
166. D 1 3 6 1 4 1 674 10892 1 600 40 1 4 Description Defines the settings of this AC power switch Syntax DellACPowerSwitchSettings Access Read write AC Power Switch Redundancy Status Name aCPowerSwitchRedundancyStatus Object ID 1 3 6 1 4 1 674 10892 1 600 40 1 5 Description Defines the redundancy status of this AC power switch Syntax DellStatusRedundancy Access Read only AC Power Cord Count for Redundancy Name aCPowerCordCountForRedundancy Object ID 1 3 6 1 4 1 674 10892 1 600 40 1 6 Description Defines the total number of AC power cords required for this AC power switch to have redundancy Syntax DellObjectRange Access Read only 168 Power Group AC Power Switch Name Name Object ID Description Syntax Access aCPowerSwitchName 1 3 6 1 4 1 674 10892 1 600 40 1 7 Defines the name of this AC power switch DellString Read only AC Power Switch Redundancy Mode Name Object ID Description Syntax Access aCPowerSwitchRedundancyMode 1 3 6 1 4 1 674 10892 1 600 40 1 8 Defines the redundancy mode of this AC power switch DellACPowerSwitchRedundancyMode Read write AC Power Switch Status Name aCPowerSwitchStatus Object ID 1 3 6 1 4 1 674 10892 1 600 40 1 9 Description Defines the status of this AC power switch Syntax DellStatus Access Read only AC Power Cord Table Name aCPowerCordTable Object ID 1 3 6 1 4 1 674 10892 1 600 42 Description Defines the AC Power Cord Table Syntax SEQUENCE OF ACPo
167. Data Value deviceTypeDeatilIsOther 1 The detailed device type is not one of the following deviceTypeDetailIsUnknown 2 The detailed device type is unknown deviceTypeDetaillIsFastPaged 3 The detailed device type is fast paged deviceTypeDetailIsStaticColumn 4 The detailed device type is static column deviceTypeDetaillsPseudoStatic 5 The detailed device type is pseudo static deviceTypeDetailIsRAMBUS 6 The detailed device type is RAMBUS deviceTypeDetailIsSynchronous 7 The detailed device type is synchronous Device Group 337 Table 13 17 Memory Device Type Details continued Variable Name De 1 1MemoryDeviceTypeDetails Data Type Integer Possible Data Values Meaning of Data Value deviceTypeDetailIsCMOS 8 The detailed device type is CMOS deviceTypeDetailIsEDO 9 The detailed device type is EDO deviceTypeDetailIsWindowDRAM 10 The detailed device type is Window DRAM deviceTypeDetailIsCacheDRAM 11 The detailed device type is Cache DRAM deviceTypeDetaillIsNonVolatile 12 The detailed device type is Non volatile deviceTypeDetaillsRegistered 13 The detailed device type is registered deviceTypeDetaillIsNonRegistered 14 The detailed device type is non registered Table 13 18 Generic Device Type Variable Name De11GenericDeviceTyp Data Type Integer Possible Dat
168. De 1 1ResourcelInterruptType Data Type Integer Possible Data Values Meaning of Data Value interruptIsLevelSensitive 1 The interrupt type is level sensitive interruptIsLatched 2 The interrupt type is latched Table 7 6 Resource Interrupt Trigger Variable Name De 1 1ResourcelInterruptTrigger Data Type Integer Possible Data Values Meaning of Data Value interruptIsActiveWhenLow 1 The interrupt trigger is active on a low signal interruptIsActiveWhenHigh 2 The interrupt trigger is active on a high signal Table 7 7 Resource DMA Bus Master Variable Name Del 1ResourceDMABusMaster Data Type Integer Possible Data Values Meaning of Data Value dmaIsOther 1 The DMA bus master capability is not one of the following dma IsUnknown 2 The DMA bus master capability is unknown dmaIsNotABusmaster 3 The DMA does not have bus master capability 146 System Resource Group Table 7 8 Resource DMA Transfer Width Variable Name De 1 1 ResourceDMATransferWidth Data Type Integer Possible Data Values Meaning of Data Value dmaTransferWidthIsOther 1 The DMA transfer width is not one of the following dmaTransferWidthIsunknown 2 The DMA transfer width is unknown dmaTransferWidthIs8Bits 3 The DMA transfer width is 8 bits dmaTransferWidthIs16Bits 4 The DMA transfer width is 16 bits dmaTransferWidthIs32Bits 5 Th
169. Defines the state and settings of the USB port DellStateSettings Read write uSBPortStatus 1 3 6 1 4 1 674 10892 1 1000 90 1 5 Defines the state of the USB port DellStatus Read only USB Port Security State Name Object ID Description Syntax Access uSBPortSecurityState 1 3 6 1 4 1 674 10892 1 1000 90 1 6 Defines the security settings of the USB port DellPortSecurityState Read only PortGroup 251 USB Port Connector Type Name uSBPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 7 Description Defines the connector type of the USB port Syntax DellUSBPortConnectorType Access Read only USB Port Name Name uSBPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 8 Description Defines the name of the USB port Syntax DellString Access Read only USB Port BIOS Connector Type Name uSBPortBlOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 9 Description Defines the BIOS connector type of the USB port Syntax DellGenericPortConnectorlype Access Read only 252 Port Group Port Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 12 1 Pointing Port Connector Type Variable Name De11PointingPortConnectorType Data Type Integer Possible Data Values Meaning of Data Value connectorPortTypelsOther 1 The pointing port connector type is not one of the following connect
170. Dell OpenManage Server Administrator Version 6 2 SNMP Reference Guide DOLL Notes and Cautions NOTE A NOTE indicates important information that helps you make better use of your computer A CAUTION A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed Information in this document is subject to change without notice 2003 2009 Dell Inc All rights reserved Reproduction of these whatsoever without the written permission of Dell Inc is strictly forbidden Trademarks used in this text Dell the DELL logo PowerEdge PowerVault and OpenManage are trademarks of Dell Inc Microsoft Windows and Windows NT are either trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries Intel Itanium Pentium Atom and Celeron are registered trademarks and MMX Xeon Core and Intel386 are trademarks of Intel Corporation in the United States and or other countries UNIX is a registered trademark of The Open Group in the United States and in other countries VESA is a registered trademark of the Video Electronics Standards Association AMD AMD Athlon AMD Opteron AMD Sempron AMD Turion AMD Phenom and AMD Duron are trademarks of Advanced Micro Devices Inc Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Dell Inc disclaims any proprietary interest
171. Description Defines the combined status of all processor devices of this chassis Syntax DellStatus Access Read only System State Processor Device Status List Name systemStateProcessorDeviceStatusList Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 51 Description Lists the status of each processor device of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a processor device The first byte returned represents the status of the first processor device and so on The bytes have the same definition type as DellStatus Syntax OCTET STRING SIZE 1 128 Access Read only System State Battery Status Combined Name systemStateBatteryStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 52 Description Defines the combined status of all batteries of this chassis Syntax DellStatus Access Read only System State Battery Status List Name systemStateBatteryStatusList Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 53 68 System State Group Description Syntax Access systemStateBatteryStatusList Lists the status of each battery of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a battery The first byte returned represents the status of the first battery and so on The bytes have the same definition type as DellStatus OCTET STRING SIZE 1 128 Read only System State SD
172. Description Defines the index one based of this chassis Syntax CooTableEntry Access Read only COO State Name cooState Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 2 Description Defines the acquisition state of the system Syntax DellStateSettings Access Read only COO Acquisition Purchase Cost Name cooAquisitionPurchaseCost Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 3 Description Defines the purchase cost of the system Syntax DellUnsigned32BitRange Access Read write 428 Cost of Ownership Group COO Acquisition Waybill Number Name Object ID Description Syntax Access cooAquisitionWayBillNumber 1 3 6 1 4 1 674 10892 1 1600 10 1 4 Defines the waybill number of the system DellUnsigned32BitRange Read write COO Acquisition Install Date Name Name Object ID Description Syntax Access cooAquisitionInstallDateName 1 3 6 1 4 1 674 10892 1 1600 10 1 5 Defines the installation date and time for the system DellDateName Read write COO Acquisition Purchase Order Name Object ID Description Syntax Access cooAquisitionPurchaseOrder 1 3 6 1 4 1 674 10892 1 1600 10 1 6 Defines the purchase order number of the system DellUnsigned32BitRange Read write COO Acquisition Purchase Date Name Name Object ID Description Syntax Access cooAquisitionPurchaseDateName 1 3 6 1 4 1 674 10892 1 1600 10 1 7 Defines the purchase date and time of the system DellDateName Read write Cost of Ownersh
173. DriverVersionName 1 3 6 1 4 1 674 10892 1 1100 90 1 10 Defines the version of the driver for the network device DellString Read only Network Device IP Address Name Object ID Description Syntax Access networkDevicelIPAddress 1 3 6 1 4 1 674 10892 1 1100 90 1 11 Defines the IP address of the network device IpAddress Read only Network Device IP Subnet Mask Name Object ID Description Syntax Access 304 networkDevicelIPSubnetMask 1 3 6 1 4 1 674 10892 1 1100 90 1 12 Defines the IP subnet mask for the IP address currently assigned to the network device IpAddress Read only Device Group Network Device Default Gateway IP Address Name networkDeviceDefaultGatewayIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 13 Description Defines the IP address of the default gateway for the network device Syntax IpAddress Access Read only Network Device DHCP Server IP Address Name networkDeviceDHCPServerIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 14 Description Defines the IP address of the DHCP server that was used to obtain the IP address of the network device if DHCP was used to configure the network device Syntax IpAddress Access Read only Network Device Current MAC Address Name networkDeviceCurrentMACAddress Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 15 Description Defines the current MAC address of the network device Syntax DellIMACAddress Acces
174. Enclosure Management Module Number Name enclosureManagementModuleNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 1 Description Identifies the instance number of the enclosure management module entry Syntax Integer Access Read only Enclosure Management Module Name Name enclosureManagementModuleName Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 2 Description Identifies the enclosure management module s name as represented in Storage Management Syntax DisplayString Access Read only Enclosure Management Module Vendor Name enclosureManagementModuleVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 3 Description Identifies the enclosure management module s re seller s name Syntax DisplayString Access Read only 626 Storage Management Group Enclosure Management Module State Name Object ID Description Syntax Access enclosureManagementModuleState 1 3 6 1 4 1 674 10893 1 20 130 13 1 4 Identifies the current state of the enclosure management module Possible states 0 Unknown 1 Ready 2 Failed 3 Online 4 Offline 5 Not Installed 6 Degraded 21 Missing Integer Read only Enclosure Management Module Severity Name Object ID Description Syntax Access enclosureManagementModuleSeverity 1 3 6 1 4 1 674 10893 1 20 130 13 1 5 This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Integer Read only
175. Enclosure Management Module Part Number Name Object ID Description Syntax Access enclosureManagementModulePartNumber 1 3 6 1 4 1 674 10893 1 20 130 13 1 6 Identifies the part number of the enclosure memory module Display String Read only Storage Management Group 627 Enclosure Management Module Type Name enclosureManagementModuleType Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 7 Description Identifies the type of the enclosure management module Possible values 0 Unknown 1 EMM 2 Termination Card Syntax Integer Access Read only Enclosure Management Module Firmware Version Name enclosureManagementModuleFWVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 8 Description Identifies the firmware version of the enclosure memory module Syntax DisplayString Access Read only Enclosure Management Module Maximum Speed Name enclosureManagementModuleMaxSpeed Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 9 Description Identifies the maximum bus speed of the enclosure management module Syntax DisplayString Access Read only 628 Storage Management Group Enclosure Management Module Roll Up Status Name Object ID Description Syntax Access enclosureManagementModuleRollUpStatus 1 3 6 1 4 1 674 10893 1 20 130 13 1 10 Severity of the enclosure management module state This is the combined status of the EMM and its components Possible values 1 Other 2 Unknown 3 OK 4 Non criti
176. F SystemStateTableEntry Access Not accessible System State Table Entry Name systemStateTableEntry Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 Description Defines the System State Table entry Syntax SystemStateTableEntry Access Not accessible Index systemStatechassisIndex System State Group 51 System State Chassis Index Name systemStatechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only System State Global System Status Name systemStateGlobalSystemStatus Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 2 Description Defines the global system status of all chassis being monitored by this instrumentation instance Syntax DellStatus Access Read only System State Chassis State Name systemStateChassisState Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 3 Description Defines the system state of this chassis Syntax DellStateSettings Access Read only System State Chassis Status Name systemStateChassisStatus Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 4 Description Defines the system status of this chassis Syntax DellStatus Access Read only 52 System State Group System State Power Unit State Details Name Object ID Description Syntax Access systemStatePowerUnitStateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 5 Defines the state of all power units in this chassis The results are returned as a bin
177. FruTableEntry Access Not accessible FRU Table Entry Name fruTableEntry Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 Description Defines the FRU Table Entry Syntax FruTableEntry Access Not accessible Index fruChassisIndex frulndex Field Replaceable Unit Group 537 FRU Chassis Index Name fruChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 1 Description Defines the index one based of the chassis containing the FRU Syntax DellObjectRange Access Read only FRU Index Name fruIndex Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 2 Description Defines the index one based of the FRU Syntax DellObjectRange Access Read only FRU Information Status Name fruInformationStatus Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 3 Description Defines the status of the FRU table entry Syntax DellStatus Access Read only FRU Information State Name fruInformationState Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 4 Description Defines the state of the FRU information Some information for the FRU may not be available if the state is other than ok 1 Syntax DellFRUInformationState Access Read only 538 Field Replaceable Unit Group FRU Device Name Name fruDeviceName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 5 Description Defines the device name of the FRU Syntax DisplayString SIZE 0 64 Access Read only FRU Manufacturer Name Name fruManufacturerName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 6
178. HCPEnabled 32 The dial up functionality uses DHCP to obtain an IP address for the dial in feature dialInAuthAnyEnabled The dial up functionality accepts any authentication 64 type including clear text for the dial in feature dialInAuthEncrypted The dial up functionality uses only encrypted Enabled 128 passwords CHAP authentication type for the dial in feature dialInAuthMschapEnab The dial up functionality uses only MSCHAP led 256 authentication type for the dial in feature Table 19 24 Remote Dial Up Modem Dial Type Variable Name De 1 1RemoteDialUpModemDialType Data Type Integer Possible Data Values Meaning of Data Value remoteDialUpIsOther 1 The remote dial type is not one of the following remoteDialUpIsUnknown 2 The remote dial type is unknown remoteDialUpIsTone 3 The remote dial type is tone remoteDialUpIsPulse 4 The remote dial type is pulse 512 Remote Access Group Table 19 25 Remote User Dial In State Capabilities Variable Name De 1 1RemoteUserDialInStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The dial in user has no state capabilities unknownCapabilities 1 The dial in user state capabilities are unknown enableCapable 2 The dial in user can be disabled or enabled notReadyCapable 4 The dial in user can be in the not ready state dialInCallback
179. IZE 0 15 Access Read write Remote User Dial In Configuration PPP User Password Name Name remoteUserDialInCfgPPPUserPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 8 Description Defines the PPP password of this remote access dial in user Syntax DisplayString SIZE 0 15 Access Read write 496 Remote Access Group Remote User Dial In Configuration Callback Phone Number Name Name remoteUserDialInCfgCallbackPhoneNumberName Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 9 Description Defines the callback phone number for this remote access dial in user Syntax DisplayString SIZE 0 95 Access Read write Remote Dial Out Table Name remoteDialOutTable Object ID 1 3 6 1 4 1 674 10892 1 1700 60 Description Defines the Remote Access Dial Out Table Syntax SEQUENCE of RemoteDialOutTableEntry Access Not accessible Remote Dial Out Table Entry Name remoteDialOutTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 Description Defines the Remote Access Dial Out Table entry Syntax RemoteDialOutTableEntry Access Not accessible Index remoteDialOutChassisIndex remoteDialOutAdapterIndex remoteDialOutDialOutIndex Remote Dial Out Chassis Index Name remoteDialOutChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellObjectRange Access Read only Remote Access Group 497 Remote Dial Out A
180. Integer Read only Array Disk Roll Up Status Name Object ID Description Syntax Access arrayDiskRollUpStatus 1 3 6 1 4 1 674 10893 1 20 130 4 1 23 Severity of the array disk state This is the combined status of the array disk and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Storage Management Group 593 Array Disk Component Status Name arrayDiskComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 24 Description The status of the array disk itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Array Disk Device Name Name arrayDiskDeviceName Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 25 Description Identifies the operating system device name for this disk Syntax DisplayString Access Read only Array Disk Nexus ID Name arrayDiskNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 26 Description Indicates the durable unique ID for this array disk Syntax DisplayString Access Read only 594 Storage Management Group Array Disk Part Number Name arrayDiskPartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 27 Description Indicates the part number of the disk Syntax DisplayString Access Read only Array Disk SAS Address Name arrayDiskSASAddre
181. Keyboard Port Connector Type Name keyboardPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 20 1 7 Description Defines the connector type of the keyboard port Syntax DellKeyboardPortConnectorType See Table 12 2 Access Read only Keyboard Port Name Name keyboardPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 20 1 8 Description Defines the name of the keyboard port Syntax DellString Access Read only 230 Port Group Keyboard Port BIOS Connector Type Name Object ID Description Syntax Access keyboardPortBlOSConnectorType 1 3 6 1 4 1 674 10892 1 1000 20 1 9 Defines the BIOS connector type of the keyboard port DellGenericPortConnectorType Read only Processor Port Table Name Object ID Description Syntax Access processorPortTable 1 3 6 1 4 1 674 10892 1 1000 30 Defines the Processor Port Table IntegerProcessorPortTableEntry Not accessible Processor Port Table Entry Name Object ID Description Syntax Access Index processorPortTableEntry 1 3 6 1 4 1 674 10892 1 1000 30 1 Defines the Processor Port Table entry ProcessorPort TableEntry Not accessible processorPortchassisIndex processorPortIndex Processor Port Chassis Index Name Object ID Description Syntax Access processorPortchassisIndex 1 3 6 1 4 1 674 10892 1 1000 30 1 1 Defines the index one based of this chassis DellObjectRange Read only PortGroup 231 Processor Port Index Name processorPort I
182. Local Response Agent Group The Local Response Agent Group provides information about various attributes of your system s local response agent LRA The LRA allows systems managers to predetermine how a system running the server administrator will respond to a particular event type such as the loss of redundancy in a specific component or the elevation of temperature in a chassis Systems managers can configure the LRA to respond to an event type with a specific action When the condition of the critical component worsens the systems manager can escalate the response to make it more obvious to the operator For example when a voltage probe on a monitored machine reaches a warning condition the systems manager may want to notify the operator by causing the machine to beep When the voltage probe reaches failure the systems manager might want to have the system that has a failing component send a broadcast message to the management system and power off the troubled system LRA Group Tables The following management information base MIB tables define LRA variable attributes e LRA Global Settings Table e LRA Action Table LRA Global Settings The global settings table allows the systems manager to determine what LRA capabilities exist for a specific system that is running Server Administrator Some machines may support all or some of the capabilities described in DellLocalResponseAgentCapabilities Unique The LRA Global Settings Table
183. Name Name powerSupplyConnectionEnclosureName Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 4 Description Identifies the name of the enclosure as represented in Storage Management to which this power supply belongs Syntax DisplayString Access Read only Power Supply Connection Enclosure Number Name powerSupplyConnectionEnclosureNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 5 Description Identifies the instance number of the enclosure in the enclosureTable to which this power supply belongs Syntax Integer Access Read only Storage Management Group 617 Temperature Probe Table This table describes available properties for each temperature probe on the managed system The following object sets up the Temperature Probe Table Name temperatureProbeTabl Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 Description A table of managed temperature probes The number of entries is related to the number of temperature probes discovered in the system The maximum number of entries is implementation dependent NOTE The properties in this table may not be applicable to all entries Syntax SEQUENCE OF TemperatureProbeEntry Access Not accessible Temperature Probe Entry Name temperatureProbeEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 Description An entry in the Temperature Probe Table A row in this table cannot be created or deleted by SNMP operations on columns of the table Syntax Tempera
184. Name powerSupplyTable Object ID 1 3 6 1 4 1 674 10892 1 600 12 Description Defines the Power Supply Table Syntax PowerSupply TableEntry Access Not accessible Power Supply Table Entry Name powerSupplyTableEntry Object ID 1 3 6 1 4 1 674 10892 1 600 12 1 Description Defines the Power Supply Table entry Syntax PowerSupply TableEntry Access Not accessible Index powerSupplychassisIndex powerSupplyIndex Power Supply Chassis Index Name powerSupplychassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 12 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only 152 Power Group Power Supply Index Name Object ID Description Syntax Access powerSupplyIndex 1 3 6 1 4 1 674 10892 1 600 12 1 2 Defines the index of power supply DellObjectRange Read only Power Supply State Capabilities Unique Name Object ID Description Syntax Access powerSupplyStateCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 600 12 1 3 Defines the capabilities of the power supply DellPowerSupplyStateCapabilitiesUnique See Table 8 1 Read only Power Supply State Settings Unique Name Object ID Description Syntax Access powerSupplyStateSettingsUnique 1 3 6 1 4 1 674 10892 1 600 12 1 4 Defines the state and settings of the power supply DellPowerSupplyStateSettingsUnique See Table 8 2 Read write Power Supply Status Name Object ID Description Syntax Access power
185. OST Log Table Entry Name postLogTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 Description Defines the POST Log Table entry Syntax PostLogTableEntry Access Not accessible Index postLogchassisIndex postLogRecordIndex 86 Chassis Information Group POST Log Chassis Index Name post LogchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only POST Log Record Index Name post LogRecordIndex Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 2 Description Syntax Access Defines the record number one based of the POST log DellUnsigned32BitRange Read only POST Log State Capabilities Unique Name Object ID Description Syntax Access postLogStateCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 300 30 1 3 Defines the capabilities of the object that is writing the POST log DellStateCapabilitiesLogUnique Read only POST Log State Settings Unique Name Object ID Description Syntax Access postLogStateSettingsUnique 1 3 6 1 4 1 674 10892 1 300 30 1 4 Defines the state of the object that is writing the POST log DellStateSettingsLogUnique Read write Chassis Information Group 87 POST Log Record Name postLogRecord Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 5 Description Defines the data for the specified chassis and record index in the POST log being returned Syntax DisplayString SIZE 0 10
186. OTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value maxPerformance 1 CPU power and performance management type is Maximum Performance minPower 2 CPU power and performance management type is Minimum Power osDBPM 4 CPU power and performance management type is OS Demand Based Power Management systemDBPM 8 CPU power and performance management type is System Demand Based Power Management Table 8 20 Memory Power Performance Management Type Variable Name De 1 1MemoryPowerPerformanceManagementTyp Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value maxPerformance 1 Memory power and performance management type is Maximum Performance mhz1333 2 Memory power and performance is 1333 MHz mhz1067 4 Memory power and performance is 1067 MHz mhz800 8 Memory power and performance is 800 MHz minPower 16 Memory power and performance management type 1s Minimum Power Power Group 195 196 Table 8 21 Fan Power Performance Management Type Variable Name De 1 1F anPowerPerformanceManagementTyp Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value maxPerformance 1 Fan power and per
187. Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 2 Description Defines the index of the monitor ports in this chassis Syntax DellObjectRange Access Read only Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 3 Description Defines the capabilities of the monitor port Syntax DellStateCapabilities Access Read only Monitor Port State Settings Name monitorPortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 4 Description Defines the state of the monitor port Syntax DellStateSettings Access Read write Monitor Port Status Name monitorPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 5 Description Defines the status of the monitor port Syntax DellStatus Access Read only 238 Port Group Monitor Port Security State Name monitorPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 6 Description Defines the security settings of the monitor port Syntax DellPortSecurityState Access Read only Monitor Port Connector Type Name monitorPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 7 Description Defines the connector type of the monitor port Syntax DellMonitorPortConnectorTypes See Table 12 5 Access Read only Monitor Port Name Name monitorPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 8 Description Defines the name of the monitor port Syntax DellString Access Read only Monitor Port BIOS Connector Type Name
188. Object ID 1 3 6 1 4 1 674 10892 2 3 2 2 Description Defines the previous IOM subsystem status recorded by the chassis management card Syntax DellStatus Access Read only DRsKVMPrevStatus Name DRsKVMPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 3 Description Defines the previous iKVM subsystem health status recorded by the chassis management card Syntax DellStatus Access Read only DRsRedPrevStatus Name DRsRedPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 4 Description Defines the previous redundancy status recorded by the chassis management card Syntax DellStatus Access Read only Dell RAC Out of Band Group 675 DRsPowerPrevStatus Name DRsPowerPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 5 Description Defines the previous power subsystem health status recorded by the chassis management card Syntax DellStatus Access Read only DRsFanPrevStatus Name DrsFanPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 6 Description Defines the previous fan health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsBladePrevStatus Name DRsBladePrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 7 Description Defines the previous blade subsystem health status recorded by the chassis management card Syntax DellStatus Access Read only 676 Dell RAC Out of Band Group DRsTempPrevStatus Name Object ID Description DRsTempPrevStatus 1 3 6 1 4 1 674
189. Object ID 1 3 6 1 4 1 674 10893 1 20 200 1 Description Storage Management event message number Syntax Integer Access Read only Description Event Name descriptionEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 2 Description Storage Management event message text describing the alert Syntax DisplayString Access Read only Storage Management Group 653 Location Event Name Object ID Description Syntax Access locationEvent 1 3 6 1 4 1 674 10893 1 20 200 3 Additional information identifying the location of the object causing the alert DisplayString Read only Object Name Event Name objectNameEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 4 Description Name of the object as represented in Storage Management causing the alert Syntax DisplayString Access Read only Object OID Event Name objectOIDEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 5 Description MIB OID of the object causing the alert Syntax DisplayString Access Read only Object Nexus Event Name Object ID Description Syntax Access objectNexusEvent 1 3 6 1 4 1 674 10893 1 20 200 6 Durable unique ID of the object causing the alert DisplayString Read only 654 Storage Management Group Current Status Event Name currentStatusEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 7 Description Current status of object causing the alert if applicable Syntax DellStatus Access Read only Previous Statu
190. OnWarningCapable 6 The LRA enables activation of chassis determined action s when a warning condition is detected failureCapable 8 The LRA can carry out chassis determined action s when a failure condition is detected Local Response Agent Group 425 Table 17 2 LRA Thermal Shutdown Capabilities Unique continued Variable Name De 1 1 LRAThermalShutdownCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value enableOnFailureCapable 10 The LRA enables activation of chassis determined action s when a failure condition is detected enableOnWarningOrFailure The LRA enables activation of chassis Capable 14 determined action s when either a failure or a warning condition is detected Table 17 3 Local Response Agent Settings Unique Variable Name De 1 1 LocalResponseAgentSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value speakerControl 1 LRA is set to issue a speaker beep consoleAlert 2 LRA is set to issue a console alert broadcastMessage 4 LRA is set to issue a broadcast message osShutDown 8 LRA is set to issue an operating system shutdown reboot 16 LRA is set to issue a system reboot powerCycle 32 LRA is set to issue a system power cycle powerOFF 64 LRA is set to issue a system power off executeApplication 256 LRA is set to start a user mode application allLRASettingsUnique 383
191. PeakWatts attribute was measured DellDateName Read only Power Usage Peak Amps Name Object ID Description Syntax Access powerUsagePeakAmps 1 3 6 1 4 1 674 10892 1 600 60 1 12 Defines the peak amperage reading in tenths of Amps for this entity since the date and time specified by the powerUsagePeakAmpsStartDateName attribute DellUnsigned32BitRange Read only Power Usage Peak Amps Start Date Name Name Object ID Description Syntax Access powerUsagePeakAmpsStartDateName 1 3 6 1 4 1 674 10892 1 600 60 1 13 Defines the date and time at which the data collection started for the value reported by the powerUsagePeakAmps attribute DellDateName Read only Power Usage Peak Amps Reading Date Name Name Object ID Description powerUsagePeakAmpsReadingDateName 1 3 6 1 4 1 674 10892 1 600 60 1 14 Defines the date and time at which the value reported by the powerUsagePeakAmps attribute was measured 178 Power Group Name powerUsagePeakAmpsReadingDateName Syntax DellDateName Access Read only Power Usage Idle Power Name powerUsagelIdlePower Object ID 1 3 6 1 4 1 674 10892 1 600 60 1 15 Description Defines the system idle power in Watts This is the minimum power the system can consume based on the current hardware configuration Syntax DellUnsigned32BitRange Access Read only Power Usage Max Potential Power Name powerUsageMaxPotentialPower Object ID 1 3 6 1 4 1 674 10892
192. PresetNumber Capable 8 The dial in user can support callback using a preset number dialInCallbackUserSpecified The dial in user can support callback Capable 16 using a user specified number Table 19 26 Remote User Dial In State Settings Variable Name De 1 1RemoteUserDialInStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The dial in user has no state settings unknown 1 The dial in user state settings are unknown enabled 2 The dial in user is enabled not Ready 4 The dial in user is in the not ready state dialInCallbackPresetNumber Enabled 8 Callback using a preset number is enabled for the dial in user dialInCallbackUserSpecified Enabled 16 Callback using a user specified number is enabled for the dial in user Remote Access Group 513 Table 19 27 Remote Dial Out State Capabilities Variable Name De 1 1RemoteDialOutStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The dial out destination has no state capabilities unknownCapabilities 1 The dial out destination state capabilities are unknown enableCapable 2 The dial out destination can be disabled or enabled notReadyCapable 4 The dial out destination can be in the not ready state dial Out PPPAuthAnyCapable 8 The dial out destination can
193. Range Device Group Name sdCardDeviceChassisIndex Access Read only SD Card Device Index Name sdCardDeviceIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 2 Description Defines the index one based of the SD Card device Syntax DellObjectRange Access Read only SD Card Device Status Name sdCardDeviceStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 3 Description Defines the status of the SD Card device Syntax DellStatus Access Read only SD Card Device Type Name sdCardDeviceType Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 4 Description Defines the type of the SD Card device Syntax DellSDCardDeviceType Access Read only SD Card Device Config Capabilities Name sdCardDeviceConfigCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 5 Description Defines the configuration capabilities of the SD Card device Syntax DellSDCardDeviceConfigCapabilities Device Group 315 Name sdCardDeviceConfigCapabilities Access Read only SD Card Device Config Settings Name sdCardDeviceConfigSettings Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 6 Description Defines the configuration settings of the SD Card device Syntax DellSDCardDeviceConfigSettings Access Read only SD Card Device Location Name Name sdCardDeviceLocationName Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 7 Description Defines the location of the SD Card device Syntax DellString Access Read only SD Card Device Card Present N
194. Read only DRsPowerSurplus Name DRsPowerSurplus Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 5 Description Defines the power surplus in Watts remaining above the drsPotentialPower reading Syntax DellPowerReading Access Read only 682 Dell RAC Out of Band Group DRsKWhCumulative Name Object ID Description DRskKWhCumulative 1 3 6 1 4 1 674 10892 2 4 1 1 6 Defines the cumulative chassis power usage in KWh since last reset Syntax DellPowerReading Access Read only DRsKWhCumulativeTime Name DRsKWhCumulativeTime Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 7 Description Defines the timestamp of the most recent chassis power accumulator reset Syntax DellTimestamp Access Read only DRsWattsPeakUsage Name DRsWattsPeakUsage Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 8 Description Defines the chassis peak power usage in Watts since last reset Syntax DellPowerReading Access Read only DRsWattsPeakTime Name DRsWattsPeakTime Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 9 Description Defines the timestamp of the most recent chassis peak power usage Syntax DellTimestamp Access Read only Dell RAC Out of Band Group 683 DRsWattsMinUsage Name DRsWattsMinUsage Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 10 Description Defines the chassis minimum power usage in Watts since last reset Syntax DellPowerReading Access Read only DRsWattsMinTime Name DRsWattsMinTime Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 11
195. Status Name Object ID Description DRsPowerCurrStatus 1 3 6 1 4 1 674 10892 2 3 1 5 Defines the power subsystem health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsFanCurrStatus Name DRsFanCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 6 Description Defines the fan subsystem health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsBladeCurrStatus Name DRsBladeCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 7 Description Defines the blade subsystem health status being monitored by the chassis management card Syntax DellStatus Access Read only Dell RAC Out of Band Group 673 DRsTempCurrStatus Name DRsTempCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 8 Description Defines the temperature sensor subsystem health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsCMCCurrStatus Name DRsCMCCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 9 Description Defines the CMC health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsGlobalPrevStatus Name DRsGlobalPrevStatus Object ID 1 3 6 1 4 1 674 10892 2 3 2 1 Description Defines the previous chassis status recorded by the chassis management card Syntax DellStatus Access Read only 674 Dell RAC Out of Band Group DRsIOMPrevStatus Name DRsIOMPrevStatus
196. Storage Management Group 639 Battery Connection Battery Name Name batteryConnectionBatteryName Object ID 1 3 6 1 4 1 674 10893 1 20 130 16 1 2 Description Identifies the name of the battery in this connection as represented in Storage Management Syntax DisplayString Access Read only Battery Connection Battery Number Name batteryConnectionBatteryNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 16 1 3 Description Identifies the instance number in the batteryTable of the battery in this connection Syntax Integer Access Read only Battery Connection Controller Name Name batteryConnectionControllerName Object ID 1 3 6 1 4 1 674 10893 1 20 130 16 1 4 Description Identifies the name of the controller as represented in Storage Management to which this battery belongs Syntax DisplayString Access Read only Battery Connection Controller Number Name batteryConnectionControllerNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 16 1 5 Description Identifies instance number of the controller in the controllerTable to which this battery belongs Syntax Integer Access Read only 640 Storage Management Group Logical Devices Group The Logical Devices Management Information Base MIB group provides information about the logical devices managed by the Dell Storage Management Software and their relationships to each other This group and all of its associated tables and objects are not supported on Microsoft Win
197. String Access Read only Enclosure Vendor Name enclosureVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 3 Description Identifies the enclosure s re seller s name Syntax DisplayString Access Read only Enclosure State Name enclosureState Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 4 Description The current condition of the enclosure which includes any devices connected to it Possible values 0 Unknown 1 Ready 2 Failed 3 Online 4 Offline 6 Degraded Syntax Integer Access Read only 576 Storage Management Group Enclosure Severity Name Object ID Description Syntax Access Enclosure ID Name Object ID Description Syntax Access enclosureSeverity 1 3 6 1 4 1 674 10893 1 20 130 3 1 5 This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Integer Read only enclosureID 1 3 6 1 4 1 674 10893 1 20 130 3 1 6 Identifies the SCSI address of the processor Integer Read only Enclosure Processor Version Name Object ID Description Syntax Access enclosureProcessorVersion 1 3 6 1 4 1 674 10893 1 20 130 3 1 7 This entry is obsolete for Storage Management DisplayString Read only Enclosure Service Tag Name Object ID Description Syntax Access enclosureServiceTag 1 3 6 1 4 1 674 10893 1 20 130 3 1 8 The enclosure identification used when consulting customer support DisplayString Read only
198. SupplyStatus 1 3 6 1 4 1 674 10892 1 600 12 1 5 Defines the status of the power supply DellStatus Read only Power Group 153 Power Supply Output Watts Name Object ID Description Syntax Access Power Supply Type Name Object ID Description Syntax Access powerSupplyOutputWatts 1 3 6 1 4 1 674 10892 1 600 12 1 6 Defines the maximum sustained output wattage of the power supply in tenths of watts DellSigned32BitRange Read only powerSupplyType 1 3 6 1 4 1 674 10892 1 600 12 1 7 Defines the type of power supply DellPowerSupplyType See Table 8 3 Read only Power Supply Location Name Name Object ID Description Syntax Access powerSupplyLocationName 1 3 6 1 4 1 674 10892 1 600 12 1 8 Defines the location name of the power supply DellString Read only Power Supply Input Voltage Name Object ID Description Syntax Access powerSupplyInputVoltage 1 3 6 1 4 1 674 10892 1 600 12 1 9 Defines the input voltage to the power supply in volts DellSigned32BitRange Read only 154 Power Group Power Supply Power Unit Index Reference Name Object ID Description Syntax Access powerSupplypowerUnitIndexReference 1 3 6 1 4 1 674 10892 1 600 12 1 10 Defines the index to the associated system power unit in this chassis DellObjectRange Read only Power Supply Sensor State Name Object ID Description Syntax Access powerSupplySensorState 1 3 6 1 4 1 674 10892 1
199. Syntax IpAddress Access Read only Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 31 Description Defines the netmask currently being used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read only Remote Access NIC Current Gateway Address Name remoteAccessNICCurrentGatewayAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 32 Description Defines the IP address for the gateway currently being used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read only 476 Remote Access Group Remote Access NIC Current Information From Dynamic Host Configuration Protocol DHCP Name Object ID Description Syntax Access remoteAccessNICCurrent InfoFromDHCP 1 3 6 1 4 1 674 10892 1 1700 10 1 33 Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware DellBoolean Read only Remote User Administration Table Name Object ID Description Syntax Access remoteUserAdminTable 1 3 6 1 4 1 674 10892 1 1700 20 Defines the Remote Access User Administration Table SEQUENCE OF Remote UserAdminTableEntry Not accessible Remote User Admin Table Entry Name Object ID Description Syntax Access Index remoteUserAdminTableEntry 1 3 6 1 4 1 674 10892 1 1700 20 1 Defines t
200. Table 650 Storage Management Event Group 653 24 Change Management Group 657 Inventory Group 4 657 Device Group 4 658 Device Group Table 658 ApplicationGroup 660 Application Group Table 661 Operating SystemGroup 663 Inventory Collector Product Information 664 25 Dell RAC Out of Band Group 667 Product Information 667 DRsProductName 667 DRsProductShortName 667 DRsProductDescription 668 DRsProductManufacturer 668 DRsProductVersion 668 DRsChassisServicelag 668 DRsProductuRL 669 DRsProductChassisAssetlag 669 DRsProductChassisLocation 669 DRsProductChassisName 669 DRsSystemServicelag 670 DRsProductSystemAssetlag 670 DRsProductSystemSlot 670 DRsProductlype 670 12 Contents DRsFirmwareVersion 671 Chassis Status 671 DRsGlobalSystemStatus 671 DRsGlobalCurrStatus 671 DRslOMCurrStatus 672 DRsKVMCurrStatus 672 DRsRedCurrStatus 672 DRsPowerCurrStatus 673 DRsFanCurrStatus 673 DRsBladeCurrStatus 6
201. Table 5 20 System Properties Variable Name De11SystemProperties NOTE These values are bit masks so combination values are possible Data Type Integer Possible Data Values Meaning of Data Value none 0 No properties energySmart 1 The system is an Energy Smart System Table 5 21 Chassis System Class Variable Name De11ChassisSystemClass Data Type Integer Possible Data Values Meaning of Data Value other 1 The chassis system class is not one of the following unknown 2 The chassis system class is unknown workstationClass 3 The chassis system class is a workstation serverClass 4 The chassis system class is a server desktopClass 5 The chassis system class is a desktop portableClass 6 The chassis system class is a portable netPCClass 7 The chassis system class is a Net PC storageClass 8 The chassis system class is storage Chassis Information Group 117 Table 5 22 Firmware Type Variable Name De11FirmwareType Data Type Integer Possible Data Values Meaning of Data Value other 1 The firmware type is other than following values unknown 2 The firmware type is unknown systemBI0S 3 The firmware type is System BIOS mbeddedSystemManagementContro_ The firmware type is Embedded ller 4 System Management Controller powerSupplyParallelingBoard 5 The firmware type is Power Supply Paralleling Board
202. The memory device port connector type is a TSOP connectorPortTypelIsARowOfChips 11 The memory device port connector type is a row of chips 256 Port Group Table 12 4 Memory Device Port Connector Types continued Variable Name De 1 1MemoryDevicePortConnectorType Data Type Integer Possible Data Value Meaning of Data Value connectorPortTypeIsRIMM 12 The memory device port connector type is a Rambus Inline Memory Module RIMM connectorPortTypeIsSODIMM 13 The memory device port connector type is a small outline dual in line memory module SODIMM connectorPortTypeIsSRIMM 14 The memory device port connector type is a SRIMM Table 12 5 Monitor Port Connector Types Variable Name De 1 1MonitorPortConnectorType Data Type Integer Possible Data Values Meaning of Data Value connectorPortTypelsOther 1 The monitor port connector type is not one of the following connectorPortTypelIsUnknown 2 The monitor port connector type is unknown connectorPortTypeIsDB15PinMale 3 The monitor port connector type is a male DB 15 connectorPortTypeIsDB15PinFemale 4 The monitor port connector type is a female DB 15 PortGroup 257 Table 12 6 SCSI Port Connector Types Data Type Integer Variable Name De11SCSIPortConnectorType Possible Data Values Meaning of Data Value
203. Threshold Name voltageProbeLowerNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 12 Description Defines the user assigned value of the voltage probe s lower noncritical threshold Syntax DellSigned32BitRange Access Read write Power Group 159 Voltage Probe Lower Critical Threshold Name Object ID Description Syntax Access voltageProbeLowerCriticalThreshold 1 3 6 1 4 1 674 10892 1 600 20 1 13 Defines the value of the voltage probe s lower critical threshold DellSigned32BitRange Read only Voltage Probe Lower Nonrecoverable Threshold Name Object ID Description Syntax Access voltageProbeLowerNonRecoverableThreshold 1 3 6 1 4 1 674 10892 1 600 20 1 14 Defines the value of the voltage probe s lower nonrecoverable threshold DellSigned32BitRange Read only Voltage Probe Probe Capabilities Name Object ID Description Syntax Access voltageProbeProbeCapabilities 1 3 6 1 4 1 674 10892 1 600 20 1 15 Defines the probe capabilities of the voltage probe DellProbeCapabilities Read only 160 Power Group Voltage Probe Discrete Reading Name Object ID Description voltageProbeDiscreteReading 1 3 6 1 4 1 674 10892 1 600 20 1 16 Defines the reading for a voltage probe of type voltageProbeTypelsDiscrete When the value for voltageProbeType is other than voltageProbe TypelsDiscrete a value is not returned for this attribute When the value for voltageProbeTyp
204. Unsigned8BitRange Read only System BIOS Characteristics Ext 2 Name Object ID Description Syntax Access systemBIOSCharacteristicsExt2 1 3 6 1 4 1 674 10892 1 300 50 1 14 Defines additional characteristics of the system BIOS This attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit Position Meaning if Set Bit OBIOS Boot Specification supported Bit 1Function key initiated Network Service boot supported Bit 2Targeted Content Distribution supported Bit 3 7Reserved DellUnsigned8BitRange Read only 96 Chassis Information Group Firmware Table Name Object ID Description Syntax Access firmwareTable 1 3 6 1 4 1 674 10892 1 300 60 Defines the Firmware Table SEQUENCE OF FirmwareTableEntry Not accessible Firmware Table Entry Name Object ID Description Syntax Access Index firmwareTableEntry 1 3 6 1 4 1 674 10892 1 300 60 1 Defines the Firmware Table entry Firmware TableEntry Not accessible firmwarechassisIndex firmwarelndex Firmware Chassis Index Name Object ID Description Syntax Access firmwarechassisIndex 1 3 6 1 4 1 674 10892 1 300 60 1 1 Defines the index one based of this chassis DellObjectRange Read only Firmware Index Name Object ID Description Syntax Access firmwareIndex 1 3 6 1 4 1 674 10892 1 300 60 1 2 Defines the index one based of the firmware in this chassis DellObjectRange Read only
205. Version 1 3 6 1 4 1 674 10892 2 1 2 1 Defines the firmware version of a chassis management controller DellString Read only Chassis Status The following MIB tables provide information on Chassis being monitored by the chassis management card DRsGlobalSystemStatus Name Object ID Description DRsGlobalSystemStatus 1 3 6 1 4 1 674 10892 2 2 1 Defines the overall chassis status being monitored by the chassis management card Syntax DellStatus Access Read only DRsGlobalCurrStatus Name DRsGlobalCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 1 Description Syntax Access Defines the overall chassis status being monitored by the chassis management card DellStatus Read only Dell RAC Out of Band Group 671 DRslOMCurrStatus Name DRslOMCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 2 Description Defines the IOM subsystem status being monitored by the chassis management card Syntax DellStatus Access Read only DRsKVMCurrStatus Name DRsKVMCurrStatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 3 Description Defines the iKVM subsystem health status being monitored by the chassis management card Syntax DellStatus Access Read only DRsRedCurrStatus Name DRsRedCurrtatus Object ID 1 3 6 1 4 1 674 10892 2 3 1 4 Description Defines the redundancy status being monitored by the chassis management card Syntax DellStatus Access Read only 672 Dell RAC Out of Band Group DRsPowerCurr
206. WidthIsl6bits 4 The system slot bus wid th is 16 bits busWidthIs32bits 5 The system slot bus wid th is 32 bits busWidthIs64bits 6 The system slot bus wid th is 64 bits busWidthIs128bits 7 The system slot bus width is 128 bits busWidthIs1xOrx1 8 The system slot bus wid th is lx or xl busWidthIs2x0Orx2 9 The system slot bus wid th is 2x or x2 busWidthIs4x0Orx4 10 The system slot bus wid th is 4x or x4 busWidthIs8xOrx8 11 356 Slot Group The system slot bus wid th is 8x or x8 Table 14 7 Hot Plug Bus Width continued Variable Name De 1 1SystemSlotHotPlugBusWidth Data Type Integer Possible Data Values Meaning of Data Value busWidthIs12xOrx12 12 The system slot bus width is 12x or x12 busWidthIs16xOrx16 13 The system slot bus width is 16x or x16 busWidthIs32x0rx32 14 The system slot bus width is 32x or x32 K NOTE System slot bus width of type n bits are for parallel buses such as PCI K NOTE System slot bus width of type nx or xn are for serial buses such as PCI Express Slot Group 357 358 Slot Group Memory Group The Memory Group provides information about the physical memory in your system Variables in this group include error correction type location and different types of memory use such as cache flash system video and nonvolatile memory Physical Memory Tabl
207. ZE 1 128 Access Read only System State Amperage Status Combined Name systemStateAmperageStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 15 Description Defines the status of all amperage probes in this chassis The result is returned as a combined status value The value has the same definition type as DellStatus Syntax DellStatus Access Read only System State Amperage Status Details Name systemStateAmperageStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 16 Description Defines the status of all amperage probes in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific amperage probe The first byte returned represents the status of the first amperage probe the second byte returned represents the status of the second amperage probe and so on The bytes have the same definition type as DellStatus Syntax OCTET STRING SIZE 1 128 Access Read only 56 System State Group System State Cooling Unit State Details Name Object ID Description Syntax Access statesystemStateCoolingUnitStateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 17 Defines the state of all cooling units in this chassis The results are returned as a binary octet string Each byte of the octet string represents the state of a specific cooling unit The first byte returned represents the state of the first cooling unit the second byte returned repre
208. a Values Meaning of Data Value none 0 No modes enabled modemBasic 1 Modem Basic mode is enabled modemPPP 2 Modem PPP mode is enabled modemTerminal 4 Modem Terminal mode is enabled directBasic 8 Direct Basic mode is enabled directPPP 16 Direct PPP mode is enabled directTerminal 32 Direct Terminal mode is enabled Baseboard Management Controller Group 533 Table 21 3 BMC Serial Flow Control Type Variable Name De 1 1BMCSerialFlowControlType Data Type Integer Possible Data Values Meaning of Data Value none 0 No flow control used rtscts 1 RTS CTS hardware flow control used xonXoff 2 XON XOFF flow control used Table 21 4 BMC Serial Bit Rate Type Variable Name De 1 1BMCSerialBitRateType Data Type Integer Possible Data Values Meaning of Data Value bps9600 6 Bit rate is 9600 bps bits per second bps19200 7 Bit rate is 19200 bps bps38400 8 Bit rate is 38400 bps bps57600 9 Bit rate is 57600 bps bps115200 10 Bit rate is 115200 bps Table 21 5 BMC LAN IP Address Source Type Variable Name De 1 1BMCLANIPAddressSourceType Data Type Integer Possible Data Values Meaning of Data Value unspecified 0 Source is unspecified static 1 IP address is static dhcp 2 Dynamic Host Configuration Protocol DHCP used to obtain IP address biosOrSystemSoftware 3 BIOS or system software provided IP Ad
209. a Values Meaning of Data Value deviceTypelIsOther 1 Device type is not one of the following deviceTypelIsUnknown 2 Device type is unknown deviceTypeIsAVideoDevice 3 Device type is a video deviceTypelIsASCSIController 4 Device type is a SCSI controller deviceTypeIsAnEthernetDevice 5 Device type is Ethernet deviceTypeIsTokenRingDevice 6 Device type is token ring deviceTypelIsASoundDevice 7 Device type is sound 338 Device Group Table 13 19 Memory Device Failure Modes Variable Name De 1 1MemoryDeviceFailureModes Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value 0 Memory device has no faults eccSingleBitCorrectionWarningRate 1 Memory device has exceeded the Correctable Memory Event warning rate eccSingleBitCorrectionFailureRate 2 Memory device has exceeded the Correctable Memory Event failure rate eccMultiBitFault 4 Memory device has encountered an Uncorrectable Memory Event eccSingleBitCorrectionLoggingDisabled 8 Correctable Memory Event logging for memory device has been disabled deviceDisabledBySpareActivation 16 Memory device is disabled because of spare memory activation Table 13 20 Network Device Connection Status Variable Name De 1 1NetworkDeviceConnectionStatus Data Type Integer Possible Data Values Meaning of Data Value unknown 0
210. accessible Index chassisIndexChassisInformation Chassis Index Chassis Information Name chassisIndexChassisInformation Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 1 Description Defines the index one based of this chassis The first chassis will be numbered one Syntax DellObjectRange Access Read only Chassis State Capabilities Name chassisStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 2 Description Defines the capabilities of the chassis Syntax DellStateCapabilities Access Read only Chassis State Settings Name chassisStateSettings Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 3 Description Defines the state settings for the chassis Syntax DellStateSettings Access Read write 72 Chassis Information Group Chassis Status Name Object ID Description Syntax Access chassisStatus 1 3 6 1 4 1 674 10892 1 300 10 1 4 Defines the status of the chassis DellStatus Read only Chassis Parent Index Reference Name Object ID Description Syntax Access Chassis Type Name Object ID Description Syntax Access Chassis Name Name Object ID Description Syntax Access chassisparentIndexReferenc 1 3 6 1 4 1 674 10892 1 300 10 1 4 Defines the index one based of the parent chassis of this chassis if any A zero 0 means that this chassis is the parent of all other chassis managed by the Server Administrator DellObjectRange Read only chassisType 1 3 6 1 4 1 674 10892 1
211. aceTableEntry Access Not accessible PCI Device Configuration Space Table Entry Name pCIDeviceConfigurationSpaceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 82 1 Description Defines the PCI Device Configuration Table entry Syntax PC DeviceConfigurationSpace TableEntry Access Not accessible Index pClIDeviceConfigurationSpacechassisIndex pClIDeviceConfigurationSpaceIndex 298 Device Group PCI Device Configuration Space Chassis Index Name Object ID Description Syntax Access pCIDeviceConfigurationSpacechassisIndex 1 3 6 1 4 1 674 10892 1 1100 82 1 1 Defines the index one based of this chassis DellObjectRange Read only PCI Device Configuration Space Index Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceIndex 1 3 6 1 4 1 674 10892 1 1100 82 1 2 Defines the index one based of the PCI device configuration in this chassis DellObjectRange Read only PCI Device Configuration Space State Capabilities Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 82 1 3 Defines the capabilities of the PCI device configuration DellStateCapabilities Read only PCI Device Configuration Space State Settings Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceStateSettings 1 3 6 1 4 1 674 10892 1 1100 82 1 4 Defines the state of the PCI device configuration DellStateSettings R
212. across critical components Table 26 5 Voltage Probe Traps Trap ID Description Cause Voltage Probe Normal 1152 Voltage sensor returned to a normal value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Voltage sensor value in Volts lt Reading gt If sensor type is discrete Discrete voltage state lt State gt A voltage sensor in the specified system returned to a valid range after crossing a failure threshold The sensor location chassis location previous state and voltage sensor value are provided Voltage Probe Warning 1153 Voltage sensor detected a warning value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Voltage sensor value in Volts lt Reading gt If sensor type is discrete Discrete voltage state lt State gt 706 Traps A voltage sensor in the specified system exceeded its warning threshold The sensor location chassis location previous state and voltage sensor value are provided Table 26 5 Voltage Probe Traps continued Trap ID Description Severity Cause Voltage Probe Failure 1154 Voltage sensor detected a Error A voltage sensor in the failure value specified system Sensor location sera tee lt Location in
213. ading 685 DRsAmpsReading 685 CMC PSU Information 685 DRsPSUChassisIndex 685 DRsPSUIndex 0 0000 686 DRsPSULocation 686 DRsPSUMonitoringCapable 686 DRsPSUVoltsReading 686 DRsPSUAmpsReading 687 DRsPSUWattsReading 687 Chassis Alerts 687 DRsCASubSystem 687 DrsCASSCurrStatus 688 DrsCASSPrevStatus 688 DrsCASSChangeTime 688 DrsCAMessage 000 688 LegacyAlerting 005 689 14 Contents DRsAlertSystem 004 689 DRsAlertTablelndexOID 689 DRsAlertMessage 689 DRsAlertCurrentStatus 690 DRsAlertPreviousStatus 690 DRsAlertData 690 20 TADS se onthe eae Ss ets Da ea dare tes 691 Trap Variables 692 SYSTEM 44 aod 4 ale OS Peel aLa d Re 692 Table Index OID 692 Message siaip es e Set wd E 692 Current Status aoaaa 693 Previous Status naaa aaaea 693 Data 24 wen a A Be eke aa h 693 Understanding the Trap Description 694 Understanding Trap Severity 698 Instrumentation Traps 699 Miscellaneous Traps 699 Temperature Probe Traps 701 Cooling Device Traps
214. al disk that has a failed disk 7 Recovering Refers to state of recovering from bad blocks on disks 11 Removed Indicates that array disk has been removed 15 Resynching Indicates one of the following types of disk operations Transform Type Reconfiguration and Check Consistency 24 Rebuild 25 No Media CD ROM or removable disk has no media 26 Formatting In the process of formatting 28 Diagnostics Diagnostics are running 34 Predictive Failure 35 Initializing Applies only to virtual disks on PERC PERC 2 SC and PERC 2 DC controllers 39 Foreign 40 Clear 41 Unsupported 53 Incompatible Integer Read only Storage Management Group 587 Array Disk Severity Name arrayDiskSeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 5 Description This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Syntax Integer Access Read only Array Disk Product ID Name arrayDiskProductID Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 6 Description Identifies the model number of the array disk Syntax DisplayString Access Read only Array Disk Serial Number Name arrayDiskSerialNo Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 7 Description Identifies the array disk s unique identification number from the manufacturer Syntax DisplayString Access Read only Array Disk Revision Name arrayDiskRevision Object ID 1 3 6 1 4 1 674 1
215. alMemoryCardInUseNumberSockets 1 3 6 1 4 1 674 10892 1 1300 60 1 8 Defines the number of memory sockets in use on the Physical Memory Card Zero indicates that the Physical Memory Card is not installed or has a configuration error DellUnsigned32BitRange Read only Memory Group Physical Memory Card Physical Memory Array Index Reference Name Object ID Description Syntax Access Memory Group Variable Values physicalMemoryCardPhyMemArrayIndexReference 1 3 6 1 4 1 674 10892 1 1300 60 1 9 Defines the index one based of the Physical Memory Array Table entry for the physical memory array with the same chassis index that this physical memory card is associated with DellObjectRange Read only This section includes definitions for server administrator specific variable values used in this section Table 15 1 Physical Memory Array Location Variable Name De11PhysicalMemoryArrayLocation Data Type Integer Possible Data Values Meaning of Data Value memoryArray LocationIsOther 1 The memory array location is not one of the following memoryArray UseIsUnknown 2 The memory array use is unknown memoryArray UselsSystemMemory 3 The memory array is system memory memoryArray UseIsVideoMemory 4 The memory array is video memory memoryArray UseIsFLASHMemory 5 The memory array is FLASH memory memoryArray UseIsNonVolatileRAMMemory 6
216. allel port capabilities are unknown Setup BIOS can enable the parallel port lpt1Capable 4 Setup BIOS can support parallel port 1 lptlandEnableCapable 6 Setup BIOS has enabled parallel port 1 lpt2Capable 8 Setup BIOS can support parallel port 2 lpt2andEnableCapable 10 Setup BIOS has enabled parallel port 2 lpt3Capable 16 Setup BIOS can support parallel port 3 lpt3andEnableCapable 18 Setup BIOS has enabled parallel port 3 allParallelPortCapable 30 Setup BIOS can support any of the three parallel ports Table 16 13 Parallel Port Control Settings Variable Name De11ParallelPortControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Parallel port state is unknown enabled 2 Setup BIOS has enabled the parallel port lpt1 4 Setup BIOS supports parallel port 1 lpt1lEnabled 6 Setup BIOS has enabled parallel port 1 lpt2 8 Setup BIOS supports parallel port 2 lpt2Enabled 10 Setup BIOS has enabled parallel port 2 lpt3 16 Setup BIOS supports parallel port 3 414 BIOS Setup Control Group Table 16 14 Parallel Port Control Mode Settings Variable Name De11ParallelPortControlModeSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Parallel port mode is unknown atModeEnabled 2 Setup BIOS h
217. ame De 1 1RemoteAccessOutOfBandSNMPCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no out of band SNMP capabilities unknownCapabilities 1 The remote access hardware out of band SNMP capabilities are unknown oobSNMPAgentCapable 2 The remote access hardware has an out of band SNMP agent oobSNMPTrapsCapable 4 The remote access hardware can send out of band SNMP traps Remote Access Group 505 Table 19 11 Remote Access Out Of Band Simple Network Management Protocol SNMP Settings Variable Name De 1 1RemoteAccessOutOfBandSNMPSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no out of band SNMP settings unknown 1 The remote access hardware out of band SNMP settings are unknown oobSNMPAgentEnabled 2 The remote access hardware out of band SNMP agent is enabled oobSNMPTrapsEnabled 4 The remote access hardware will send out of band SNMP traps Table 19 12 Remote User Admin State Capabilities Variable Name De 1 1RemoteUserAdminStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 he admin user has no state capabilities unknownCapabilities 1 he admin user state capabilities are unknown enableCapable 2 he admin user can be disabled or e
218. ame sdCardDeviceCardPresent Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 8 Description Defines whether the SD Card is present for the SD Card device Syntax DellBoolean Access Read only SD Card Device Card State Name sdCardDeviceCardState Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 9 Description Defines the state of the SD Card Syntax DellSDCardDeviceCardState 316 Device Group Name sdCardDeviceCardState Access Read only SD Card Device Card Storage Size Name sdCardDeviceCardStorageSize Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 10 Description Defines the storage size in MB megabytes of the SD card for the SD Card device Syntax DellUnsigned32BitRange Access Read only SD Card Device Unit Index Reference Name sdCardDeviceUnitIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 11 Description Defines the index to the associated SD Card unit if the SD Card device is part of a SD Card unit Syntax DellObjectRange Access Read only Device Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 13 1 Pointing Device Type Variable Name De 1 1PointingDeviceType Data Type Integer Possible Data Values Meaning of Data Value deviceTypelIsOther 1 Device type is not one of the following deviceTypelIsUnknown 2 Device type is unknown deviceTypeIsAMouse 3 Device type is a mouse Device Group
219. ame virtualDiskRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 19 Description Severity of the virtual disk state This is the combined status of the virtual disk and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 20 Description The status of the virtual disk itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Storage Management Group 649 Virtual Disk Nexus ID Name virtualDiskNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 21 Description Durable unique ID for this virtual disk Syntax DisplayString Access Read only Virtual Disk Array Disk Type Name virtualDiskArrayDiskType Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 22 Description Identifies the type of array physical disks used to create the virtual disk Possible values 1 SAS 2 SATA 3 SCSI 4 IDE 99 Unknown Syntax Integer Access Read only Array Disk Logical Connection Table This table describes the connections between array disks the virtual disk to which they belong and their associated logical disk For each object in the table its object number corresponds to an in
220. an Probe Unit Name fanProbeUnit Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 6 Description This entry is obsolete for Storage Services Syntax DisplayString Access Read only Fan Probe Minimum Warning Name fanProbeMinimumWarning Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 7 Description This entry is obsolete This setting is not supported by fans managed under Storage Management Syntax DisplayString Access Read only Fan Probe Minimum Critical Name fanProbeMinimumCritical Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 8 Description This entry is obsolete This setting is not supported by fans managed under Storage Management Syntax DisplayString Access Read only Storage Management Group 605 Fan Probe Maximum Warning Name fanProbeMaximumWarning Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 9 Description This entry is obsolete This setting is not supported by fans managed under Storage Management Syntax DisplayString Access Read only Fan Probe Maximum Critical Name fanProbeMaximumCritical Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 10 Description This entry is obsolete This setting is not supported by fans managed under Storage Management Syntax DisplayString Access Read only Fan Probe Current Value Name fanProbeCurrValue Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 11 Description Identifies the current speed of the fan Syntax DisplayString Access Read only Fan1 Part Number Nam
221. an that reads in RPMs coolingDeviceSubTypelIsAPowerSupply FanThatReads ONoroOFF 6 The cooling device subtype is a power supply fan that reads 0 off or 1 on coolingDeviceSubTypelIsDiscrete 16 The cooling device subtype is a cooling device with discrete reading Table 9 3 Cooling Device Discrete Reading Variable Name De 1 1CoolingDeviceDiscreteReading Data Type Integer Possible Data Values Meaning of Data Value coolingDeviceIsGood 1 The cooling device discrete reading is good coolingDevicelIsBad 2 The cooling device discrete reading is bad 212 Thermal Group Table 9 4 Temperature Probe Type Variable Name De 11 TemperatureProbeTyp Data Type Integer Possible Data Values Meaning of Data Value LemperatureProbeTypelsOther 1 The temperature probe subtype is not one of the following temperatureProbeTypelIsUnknown 2 The temperature probe subtype is unknown not known or not monitored temperatureProb ypeIsAmbientESM 3 The temperature probe is for ambient Embedded Systems Management ESM temperatureProbeTypelsDiscrete 16 The temperature probe subtype is a temperature probe with discrete reading Table 9 5 Temperature Probe Discrete Reading Variable Name De1 1 TemperatureDiscreteReading Data Type Integer Possible Data Values Meaning of Data Value temperaturel
222. andby amperage probe amperageProbeTypelsBattery 12 The amperage probe type is a battery amperage probe amperageProbeTypelsTerminator 13 The amperage probe type is a Small Computer System Interface SCSI termination amperage probe amperageProbeTypels2Point5Volt 14 The amperage probe type is a 2 5 V amperage probe amperageProbeTypeIsGTL 15 The amperage probe type is a Gunning Transceiver Logic GTL probe amperageProbeTypelsDiscrete 16 The amperage probe type is an amperage probe with discrete reading amperageProbeTypelsPowerSupplyAmps 23 The amperage probe type is power supply probe with reading in Amperes amperageProbeTypelsPowerSupplyWatts The amperage probe type is 24 power supply probe with reading in Watts amperageProbeTypelIsSystemAmps 25 The amperage probe type is system probe with reading in Amperes amperageProbeTypelsSystemWatts 26 The amperage probe type is system probe with reading in Watts 190 Power Group Table 8 9 Amperage Probe Discrete Reading Variable Name DellAmperageDiscreteReading Data Type Integer Possible Data Values Meaning of Data Value amperagelIsGood 1 The amperage probe discrete reading is good amperageIsBad 2 The amperage probe discrete reading is bad Table 8 10 AC Power Switch Capabilities Variable Name De 1 1ACPowerSwitchCapabilities Data Type Integer Po
223. ange INTEGER 1 2147483647 DellSigned32BitRange INTEGER 2147483647 2 147483647 DellBoolean INTEGER 0 1 FALSE 0 TRUE 1 Standard Data Type Definitions 743 Variables with Data Types of State Capabilities and State Capabilities Unique Variables with definitions of lt variable name gt StateCapabilitiesor lt variable name gt StateCapabilitiesUnidque are integers representing a series of bit definitions They are NOT enumerations and should be treated as bit fields The value is passed as a decimal value The decimal value should be converted to hex and the appropriate bits should be parsed from hex Some of the more common bit combinations are defined in some variables but not all combinations are or will be defined Table A 2 Dell State Capabilities Variable Name De11StateCapabilities Data Type Integer Possible Data Values Meaning of Data Value if set to zero 0 The object has no capabilities unknownCapabilities 1 The object s capabilities are unknown enableCapable 2 The object can be disabled offline a binary 0 value or enabled online a binary value notReadyCapable 4 The object is not ready enableAndNotReadyCapable Enable and not ready capable 6 744 Standard Data Type Definitions Table A 3 Dell State Settings Variable Name De11StateSettings Data Type Integer Possible Data Valu
224. aning of Data Value speakerControlCapable 1 The LRA can issue a speaker beep consoleAlertCapable 2 The LRA can alert the console broadcastMessageCapable 4 The LRA can broadcast a message osShutDownCapable 8 424 The LRA can shut down the operating system Local Response Agent Group Table 17 1 LRA Capabilities Definitions continued Variable Name De 1 1 LocalResponseAgentCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value rebootCapable 16 The LRA can reboot the system powerCycleCapable 32 The LRA is capable of a system power cycle powerOFFCapable 64 The LRA can shut the system power off executeApplicationCapable 256 The LRA can execute a user mode application lraFullyCapable 383 The LRA has all of the preceding capabilities Table 17 2 LRA Thermal Shutdown Capabilities Unique Variable Name De 11 LRAThermalShutdownCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value none 0 The LRA has no thermal shutdown capabilities Unknown capabilities 1 The LRA s thermal shutdown capabilities are unknown enableCapable 2 The LRA can be disabled offline a binary 0 value or enabled online a binary 1 value warningCapable 4 The LRA can carry out chassis determined action s when a warning condition is detected enable
225. ards SNMP or CIM supported by the systems management software Syntax SMSSupportedTypes See Table 3 1 Access Read only Systems Management Software Preferred Protocol Name systemManagementSoftwarePreferredProtocol Object ID 1 3 6 1 4 1 674 10892 1 100 6 Description Defines the preferred systems management standard for the systems management software Syntax SMSSupportedTypes See Table 3 1 Access Read only Systems Management Software Update Level Name Name systemManagementSoftwareUpdateLevelNam Object ID 1 3 6 1 4 1 674 10892 1 100 7 Description Defines the update level of the system management software Syntax DellString Access Read only Systems Management Software Group 47 Systems Management Software URL Name Name systemManagement SoftwareURLName Object ID 1 3 6 1 4 1 674 10892 1 100 8 Description Defines the universal resource locator URL of the systems management software Syntax DisplayString SIZE 0 1024 Access Read only Systems Management Software Language Name Name systemManagement SoftwareLanguageName Object ID 1 3 6 1 4 1 674 10892 1 100 9 Description Defines the language of the systems management software Syntax DisplayString SIZE 0 255 Access Read only Systems Management Software Global Version Name Name systemManagementSoftwareGlobalVersionName Object ID 1 3 6 1 4 1 674 10892 1 100 10 Description Defines the global version of the systems management software Syntax D
226. are designed to show information in a readable form The following table for example defines the Server Administrator specific variable DellFanControlCapabilities The table provides the name of the variable its data type the values that are valid for the variable and the meaning of each value Table 1 9 Example Variable Type Definition Table Variable Name DellFanControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The fan s capabilities are unknown lowSpeedCapable 2 The fan can be set to low speed highSpeedCapable 4 The fan can be set to high speed lowOrHighSpeedCapable 6 The fan can be set to low or high speed This type of table is used throughout the reference guide to list and define variable values Tables that explain Server Administrator specific variable values are located in the final section of sections that define Server Administrator specific variables In the preceding example the variable name is DellFanControlCapabilities This variable must be expressed as an integer and has four possible values unknown lowSpeedCapable highSpeedCapable and lowOrHighSpeed Capable Section Organization Sections in this reference guide are based on the Server Administrator MIBs so the complexity of each section depends on the complexity of each MIB group The first section provides a high level introduction to the MIB group If the group is defined by o
227. are log capacity on the specified system is Log iyos cios types near or at the capacity of the hardware log The log type information is provided Hardware Log Full 1554 Log size is full Error The size of a hardware log Log type lt Log type gt on the specified system is at the capacity of the hardware log The log type information is provided Processor Device Status Traps The BMC on some systems reports the status of processor devices Processor device status traps provide status and warning information for processor devices present in a system with a BMC that reports the status of processor devices Traps 719 720 Table 26 14 Processor Device Status Traps Trap ID Description Severity Cause Processor Device Status Normal 1602 Processor sensor Information A processor sensor in the returned to a normal specified system value transitioned back to a sensor location seine es ey sensor ieor aon anenas shes ocation chassis location previous state and processor Chassis Location lt Name sensor status are provided of chassis gt Previous state was lt State gt Processor sensor status lt status gt Processor Device Status Warning 1603 Processor sensor Warning A processor sensor in the detected a warning value Sensor Location lt Location in chassis gt Chassis Location lt Name of chassis gt Previous state was lt State gt Processor sensor status lt status gt Traps
228. ary octet string Each byte of the octet string represents the state of a specific power unit The first byte returned represents the state of the first power unit the second byte returned represents the state of the second power unit and so on The bytes have the same definition type as DellStateSettings OCTET STRING SIZE 1 128 Read only System State Power Unit Status Redundancy Name Object ID Description Syntax Access systemStatePowerUnitStatusRedundancy 1 3 6 1 4 1 674 10892 1 200 10 1 6 Defines the system status of the power unit s in this chassis DellStatus Read only System State Power Unit Status Details Name Object ID Description Syntax Access systemStatePowerUnitStatusDetails 1 3 6 1 4 1 674 10892 1 200 10 1 7 Defines the status of all power units in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific power unit The first byte returned represents the status of the first power unit the second byte returned represents the status of the second power unit and so on The bytes have the same definition type as DellStatusRedundancy OCTET STRING SIZE 1 128 Read only System State Group 53 System State Power Supply State Details Name systemStatePowerSupplyStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 8 Description Defines the state of all power supplies in this chassis The results are returne
229. as lt State gt failure threshold Tl rl i If sensor type is not aS SESA gcation j chassis location discrete y previous state and Temperature sensor value in t t ratur r degrees Celsius lt Reading gt EPR AE SEES value are provided If sensor type is discrete Discrete temperature stat lt State gt Temperature Probe Warning 1053 Temperature sensor detected Warning A temperature sensor a warning value on the backplane Sensor location board system board Location in chassiss or drive carrier in the specified system Chassis location exceeded its warning lt Name of chassis gt threshold The sensor Previous state was lt State gt location chassis l l i revi If sensor type is not oration previous state and discrete temperature sensor Temperature sensor value in l ided i value are provided degrees Celsius lt Reading gt P If sensor type is discrete Discrete temperature stat lt State gt Traps Table 26 3 Temperature Probe Traps continued Trap ID Description Severity Cause Temperature Probe Failure 1054 Temperature sensor detected Error a failure value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Temperature sensor value in degrees Celsius lt Reading gt If sensor type is discrete Discrete temperature stat lt State gt A temperature sens
230. as set the parallel port to AT mode ps2ModeEnabled 4 Setup BIOS has set the parallel port to Personal Systems 2 PS 2 mode ecpModeEnabled 8 Setup BIOS has set the parallel port to Extended Capabilities Port ECP mode eppModeEnabled 16 Setup BIOS has set the parallel port to Enhanced Parallel Port EPP mode Table 16 15 Serial Port Control Capabilities Variable Name De11SerialPortControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Setup BIOS serial port capabilities are unknown enableCapable 2 Setup BIOS can enable the serial port comlCapable 4 Setup BIOS can support serial port 1 enableAndComlCapable 6 Setup BIOS can enable serial port 1 com2Capable 8 Setup BIOS can support serial port 2 enableAndCom2Capable 10 Setup BIOS is capable of enabling serial port 2 com3Capable 16 Setup BIOS can support serial port 3 enableAndCom3Capable 18 Setup BIOS is capable of enabling serial port 3 com4Capable 32 Setup BIOS can support serial port 4 enableAndCom4Capable 34 Setup BIOS is capable of enabling serial port 4 autoConfigCapable 64 Setup BIOS is capable of autoconfiguring all serial ports BIOS Setup Control Group 415 Table 16 15 Serial Port Control Capabilities continued Variable Name De11SerialPortControlCapabilitiesUnique Data Type Integer Possible D
231. assis gt Specifies the name of the memory bank in the system that generated the message for example Memory device bank location Bank_1 Memory device location lt Device name in chassis gt Specifies the location of the memory module in the chassis for example Memory device location DIMM A Number of devices required for full Specifies the number of power supply or cooling devices required to achieve full redundancy lt Number gt redundancy for example Number of devices required for full redundancy 4 Peak value in Watts Specifies the peak value in Watts for example lt Reading gt Peak value in Watts 125 696 Traps Table 26 1 Trap Description Reference continued Description Line Item Explanation Possible memory module event cause lt list of causes gt Specifies a list of possible causes for the memory module event for example Possible memory module event cause Single bit warning error rate exceeded Single bit error logging disabled Power Supply type lt type of power supply gt Specifies the type of power supply for example Power Supply type VRM Pre failure stat lt State gt was Specifies the status of the previous memory message for example Pre failure state was Failed Previous redundancy state was lt State gt Specifies the status of the previous redundancy message for example Previous redundancy stat
232. ata Type Integer Possible Data Values Meaning of Data Value unknown 1 IDE control capabilities are unknown ideControlAutoConfigOrEnable IDE controller is autoconfigurable or Capable 2 enable capable Table 16 18 Diskette Control Settings Variable Name De11DisketteControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Diskette control state is unknown disketteControlAutoConfigEnabled Diskette control is set as OrEnabled 2 autoconfigurable or enabled Table 16 19 Network Interface Control Capabilities Variable Name DellNetworkInterfaceControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Unknown setup BIOS network interface capabilities enableCapable 2 Setup BIOS is capable of enabling the network interface enableWithoutPXECapable 4 Setup BIOS is capable of enabling the NIF without Pre boot eXecution Environment PXE BIOS Setup Control Group 417 418 Table 16 20 Network Interface Control Settings Variable Name De 1 1NetworkInterfaceControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Network interface state is unknown enabled 2 Network interface is enabled enabledWithoutPXE ti ws Network interface is enabled without PXE BIOS Setup Control Group
233. ata Values Meaning of Data Value comlOrCom3CapableAndAuto ConfigCapable 86 Setup BIOS has enabled autoconfiguration of COM1 and COM3 serial ports com20rCom4CapableAndAuto ConfigCapable 106 Setup BIOS has enabled autoconfiguration of COM2 and COM4 serial ports allcomCapable 126 Setup BIOS is capable of enabling or autoconfiguring all serial ports Table 16 16 Serial Port Control Settings Variable Name De11SerialPortControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Serial port state is unknown enabled 2 Setup BIOS has enabled the serial port coml 4 Setup BIOS has selected serial port 1 comlEnabled 6 Setup BIOS has enabled serial port 1 com2 8 Setup BIOS has selected serial port 2 com2Enabled 10 Setup BIOS has enabled serial port 2 com3 16 Setup BIOS has selected serial port 3 com3Enabled 18 Setup BIOS has enabled serial port 3 com4 32 Setup BIOS has selected serial port 4 com4Enabled 34 Setup BIOS has enabled serial port 4 comPortsAutoConfig 64 Setup BIOS has selected autoconfiguration of serial ports enabledAndAutoConfig 66 Setup BIOS has enabled autoconfiguration of serial ports 416 BIOS Setup Control Group Table 16 17 IDE Control Capabilities Variable Name De11ideControlCapabilitiesUnique D
234. ation previous state and fan sensor value are provided Cooling Device Warning 1103 704 Fan sensor detected a warning value Warning Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt Fan sensor value lt Reading gt Traps A fan sensor reading in the specified system exceeded a warning threshold The sensor location chassis location previous state and fan sensor value are provided Table 26 4 Cooling Device Traps continued Trap ID Description Severity Cause Cooling Device Failure 1104 Fan sensor detected a Error A fan sensor in the failure value specified system shcon Tovation o the a eat kon 4n ead eS of one or more fans The sensor location Chassis location lt Name of chassis location chassis gt previous state and Previous state was lt State gt fan sensor value are rovided Fan sensor value lt Reading gt Pao Cooling Device Nonrecoverable 1105 Fan sensor detected a Error A fan sensor detected non recoverable valu Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt Fan sensor value lt Reading gt an error from which it cannot recover The sensor location chassis location previous state and fan sensor value are provided Traps 705 Voltage Probe Traps Voltage probes monitor the number of volts
235. ation error gt Traps A power supply sensor has detected a warning condition The sensor location chassis location previous state and additional power supply status information are provided Table 26 9 Power Supply Traps continued Trap ID Description Severity Cause Power Supply Failure 1354 Power supply detected a Error A power supply has been failure disconnected or has failed The sensor location chassis location previous state and additional information Sensor location lt Location in chassis gt Chassis location about the power supply lt Name of chassis gt event are provided Previous state was lt State gt Power Supply type lt type of power supply gt lt Additional power supply status information gt If in configuration error state Configuration error type lt type of configuration error gt Memory Device Traps Memory device messages provide status and warning information for memory modules present in a particular system Memory devices determine health status by counting the number of ECC memory corrections K NOTE A value of failure or non recoverable does not indicate a system failure or loss of data but rather that the specified system exceeded the specified ECC correction threshold Although the system continues to function you should perform system maintenance as described in Table 26 10 Traps 715 Table 26 10 Memory Device Messages T
236. ation in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt Chassis intrusion state lt Intrusion state gt A chassis intrusion sensor in the specified system detected that the system cover was opened while the system was operating The sensor location chassis location previous state and chassis intrusion state are provided 710 Traps Redundancy Unit Traps Redundancy means that a system chassis has more than one of certain critical components Fans and power supplies for example are so important for preventing damage or disruption of a computer system that a chassis may have extra fans or power supplies installed Redundancy allows a second or nth fan to keep the chassis components at a safe temperature when the primary fan has failed Redundancy is normal when the intended number of critical components are operating Redundancy is degraded when a component fails but others are still operating Redundancy is lost when the number of components functioning falls below the redundancy threshold The number of devices required for full redundancy is provided as part of the trap message when applicable for the redundancy unit and the platform For more details on redundancy computation please refer to the respective platform documentation Table 26 8 Redundancy Unit Traps Trap ID Description Severity Cause Redundancy Normal 1304 Redundancy regained Information A r
237. ator password control Syntax DellBIOSPasswordControlCapabilitiesUnique Access Read only BIOS Setup Control Administrator Password Control Settings Unique Name bSUCadministratorPasswordControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 27 Description Defines the settings for administrator password control Syntax DellBIOS PasswordControlSettingsUnique See Table 16 9 Access Read write 390 BIOS Setup Control Group BIOS Setup Control Administrator Password Control Status Name bSUCadministratorPasswordControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 28 Description Defines the status for administrator password control Syntax DellStatus Access Read only BIOS Setup Control Administrator Password Verify Name Name bSUCadministratorPasswordVerifyName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 29 Description Defines the setup BIOS name for the current administrator password Syntax DellString Access Read write BIOS Setup Control Administrator Password New Password Name Name bSUCadministratorPasswordNewPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 30 Description Defines the setup BIOS name of the new administrator password To set a new administrator password you must have successfully set the current administrator password immediately preceding this password change Syntax DellString Access Read write BIOS Setup Control User Password Control Capabilities Unique Name bSUCuserPa
238. automatically power off host automaticAllExceptNotificationCap Watchdog controls can be set to able 27 automatically perform all functions except notification capable automaticFullyCapable 31 Watchdog controls can be set to automatically perform all functions 114 Chassis Information Group Table 5 14 Watchdog Control Settings Variable Name De 1 1WatchControlSettings NOTE The watchdog timer is the mechanism used by a chassis to determine if the operating system has stopped responding Data Type Integer Possible Data Values Meaning of Data Value automat icRebootEnabled 1 Automatic reboot is enabled for this host automaticPowerCycleEnabled 2 Automatic power cycleable is enabled for this host automaticNotificationEnabled 4 Automatic notification is enabled for this host automat icPowerOffEnabled 8 Automatic power off is enabled for this host Table 5 15 Watchdog Timer Capabilities Variable Name De1 1Wat chDogTimerCapabilities Data Type Integer Possible Data Values Meaning of Data Value typelCapable 1 Watchdog timer can time in intervals from 20 480 seconds type2Capable 2 Watchdog timer can time in 30 60 120 and 480 second intervals type3Capable 4 Watchdog timer can time in 60 second intervals Chassis Information Group 115 Table 5 16 Power Button Control Capabilities Variable Name Del 1PowerButto
239. ax Access chassisLockPresent 1 3 6 1 4 1 674 10892 1 300 10 1 30 Specifies whether a chassis lock is present on the chassis DellBoolean Read only Chassis Host Control Capabilities Unique Name Object ID Description Syntax Access chassishostControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 300 10 1 31 Defines the capabilities of the host control object DellHostControlCapabilities See Table 5 11 Read only Chassis Information Group 79 Chassis Host Control Settings Unique Name chassishostControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 32 Description Defines the current settings of the host control object Syntax DellHostControlSettings See Table 5 12 Access Read write Chassis Watchdog Control Capabilities Unique Name chassiswatchDogControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 33 Description Defines the capabilities of the watchdog timer object Syntax DellWatchDogControlCapabilities See Table 5 13 Access Read only Chassis Watchdog Control Settings Unique Name chassiswatchDogControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 34 Description Defines the current settings and the values allowed to be set for the watchdog timer object Syntax DellWatchDogControlCapabilities See Table 5 13 Access Read write Chassis Watchdog Control Expiry Time Capabilities Unique Name chassiswatchDogControlExpiryTimeCapabilities Unique Object ID 1
240. ayString Read only Array Disk Enclosure Connection Enclosure Number Name Object ID Description Syntax Access arrayDiskEnclosureConnectionEnclosureNumber 1 3 6 1 4 1 674 10893 1 20 130 5 1 5 Identifies the instance number in the enclosureTable of the enclosure to which this array disk belongs Integer Read only Storage Management Group _ 599 Array Disk Enclosure Connection Controller Name Name arrayDiskEnclosureConnectionControllerName Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 6 Description Identifies the name of the controller as represented in Storage Management to which this array disk is connected Syntax DisplayString Access Read only Array Disk Enclosure Connection Controller Number Name arrayDiskEnclosureConnectionControllerNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 7 Description Identifies the instance number in the controllerTable of the controller to which this array disk is connected Syntax Integer Access Read only Array Disk Channel Connection Table This table describes the connections between array disks their channel and their associated controller For each object in the table its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found K NOTE Only array disks that are NOT part of an enclosure will be listed in this table Backplanes are considered enclosures by Sto
241. beLowerNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 12 Description Defines the user assigned value of the amperage probe s lower noncritical threshold Syntax DellSigned32BitRange Access Read write Amperage Probe Lower Critical Threshold Name amperageProbeLowerCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 13 Description Defines the value of the amperage probe s lower critical threshold Syntax DellSigned32BitRange Access Read only Power Group 165 Amperage Probe Lower Nonrecoverable Threshold Name Object ID Description Syntax Access amperageProbeLowerNonRecoverableThreshold 1 3 6 1 4 1 674 10892 1 600 30 1 14 Defines the value of the amperage probe s lower nonrecoverable threshold DellSigned32BitRange Read only Amperage Probe Probe Capabilities Name Object ID Description Syntax Access amperageProbeProbeCapabilities 1 3 6 1 4 1 674 10892 1 600 30 1 15 Defines the probe capabilities of the amperage probe DellProbeCapabilities Read only Amperage Probe Discrete Reading Name Object ID Description Syntax Access amperageProbeDiscreteReading 1 3 6 1 4 1 674 10892 1 600 30 1 16 Defines the reading for a amperage probe of type amperageProbeTypelsDiscrete When the value for amperageProbeType is other than amperageProbeTypelsDiscrete a value is not returned for this attribute When the value for amperageProbeType is amperageP
242. bilities Object ID 1 3 6 1 4 1 674 10892 1 600 50 1 3 Description Defines the state capabilities of the battery Syntax DellStateCapabilities Access Read only Battery State Settings Name batteryStateSettings Object ID 1 3 6 1 4 1 674 10892 1 600 50 1 4 Description Defines the state settings of the battery Syntax DellStateSettings Access Read write Battery Status Name batteryStatus Object ID 1 3 6 1 4 1 674 10892 1 600 50 1 5 Description Defines the status of the battery Syntax DellStatus Access Read only Battery Reading Name batteryReading Object ID 1 3 6 1 4 1 674 10892 1 600 50 1 6 Description Defines the reading of the battery Syntax DellBatteryReading see Table 8 15 Access Read only Power Group 173 Battery Location Name Name batteryLocationName Object ID 1 3 6 1 4 1 674 10892 1 600 50 1 7 Description Defines the location of the battery Syntax DellString Access Read only Power Usage Table Name powerUsageTable Object ID 1 3 6 1 4 1 674 10892 1 600 60 Description Defines the Power Usage Table Syntax SEQUENCE OF PowerUsageTableEntry Access Not accessible Power Usage Table Entry Name powerUsageTableEntry Object ID 1 3 6 1 4 1 674 10892 1 600 60 1 Description Defines the Power Usage Table Entry Syntax PowerUsageTableEntry Access Not accessible Index powerUsageChassisIndex powerUsageIndex Power Usage Chassis Index Name powerUsageChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 60 1
243. blade connectivitySwitch 4 The baseboard type is a connectivity switch systemManagementModule 5 The baseboard type is a system management module processorModule 6 The baseboard type is a processor module ioModule 7 The baseboard type is an I O module memoryModule 8 The baseboard type is a memory module daughterBoard 9 The baseboard type is a daughter board motherboard 10 The baseboard type is a mother board processorMemoryModule 11 The baseboard type is a processor or memory module processorIOModule 12 The baseboard type is a processor or I O module interconnectBoard 13 The baseboard type is an interconnect board Chassis Information Group 119 120 Table 5 24 Baseboard Feature Flags Variable Name De 1 1BaseBoardFeatureFlags Data Type Integer Possible Data Values Meaning of Data Value NOTE These values are bit fields so combination values are possible no features 0 This baseboard has no feature flags boardIsHostingBoard 1 This baseboard is a hosting board boardRequiresDaughterBoard This baseboard requires at least one 2 daughter board or auxiliary card boardIsRemovable 4 This baseboard is removable boardIsReplaceable 8 This baseboard is replaceable boardIsHotSwappable 16 This baseboard is hot swappable Chassis Information Group Operating System Group The Operating System Group provides status and identifying information about a system
244. ble Syntax SEQUENCE OF DrsCMCPSUTableEntry Access Not accessible 680 Dell RAC Out of Band Group DRsCMC PSUTableEntry Name Object ID Description Syntax Access DrsCMCPSUTableEntry 1 3 6 1 4 1 674 10892 2 4 2 1 Defines the CMC PSU table entry DrsCMCPSUTableEntry Not accessible CMC Power Information The following MIB tables provide information on the chassis power DRsChassisIndex Name Object ID Description DrsChassisIndex 1 3 6 1 4 1 674 10892 2 4 1 1 1 Defines the index one based of the associated chassis Syntax DellCMCPowerIndexRange Access Read only DRsPotentialPower Name DRsPotentialPower Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 2 Description Syntax Access Defines the power in Watts required by the chassis infrastructure plus the sum of the maximum power requirements for all systems currently turned on DellPowerReading Read only Dell RAC Out of Band Group 681 DRsldlePower Name DRsIdlePower Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 3 Description Defines the power in Watts required by the chassisinfrastructure plus the sum of the minimum power requirements for all systems currently turned on Syntax DellPowerReading Access Read only DRsMaxPowerSpecification Name DRsMaxPowerSpecification Object ID 1 3 6 1 4 1 674 10892 2 4 1 1 4 Description Defines the power limit in Watts at which server throttling will take place Syntax DellPowerReading Access
245. cal 5 Critical 6 Non recoverable DellStatus Read only Enclosure Management Module Component Status Name Object ID Description Syntax Access enclosureManagementModuleComponentStatus 1 3 6 1 4 1 674 10893 1 20 130 13 1 11 The status of the enclosure management module itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Storage Management Group 629 Enclosure Management Module Nexus ID Name enclosureManagementModuleNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 12 Description Durable unique ID for this EMM Syntax DisplayString Access Read only Enclosure Management Module Revision Name enclosureManagementModuleRevision Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 13 Description Identifies the revision number of the enclosure management module Syntax DisplayString Access Read only Enclosure Management Module Connection Table This table describes the connection between each enclosure management module on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table The following object sets up the Enclosure Management Module Connection Table Name enclosureManagementModuleConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 14 Description Defines the enclosure memory module
246. calThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 10 Description Defines the value of the fan s upper critical threshold Syntax DellSigned32BitRange Access Read only Cooling Device Upper Noncritical Threshold Name coolingDeviceUpperNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 11 Description Defines the user assigned value of the fan s upper noncritical threshold Syntax DellSigned32BitRange Access Read write Cooling Device Lower Noncritical Threshold Name coolingDeviceLowerNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 12 Description Defines the user assigned value of the fan s lower noncritical threshold Syntax DellSigned32BitRange Access Read write ThermalGroup 203 Cooling Device Lower Critical Threshold Name Object ID Description Syntax Access coolingDeviceLowerCriticalThreshold 1 3 6 1 4 1 674 10892 1 700 12 1 13 Defines the value of the fan s lower critical threshold DellSigned32BitRange Read only Cooling Device Lower Nonrecoverable Threshold Name Object ID Description Syntax Access coolingDeviceLowerNonRecoverableThreshold 1 3 6 1 4 1 674 10892 1 700 12 1 14 Defines the value of the fan s lower nonrecoverable threshold DellSigned32BitRange Read only Cooling Device Cooling Unit Index Reference Name Object ID Description Syntax Access coolingDevicecoolingUnitIndexReference 1 3 6 1 4 1 674 10892 1 700 12 1 15
247. ccess serialPortControlTableEntry 1 3 6 1 4 1 674 10892 1 1400 40 1 Defines the Serial Port Control Table entry SerialPortControl TableEntry Not accessible 398 BIOS Setup Control Group Name serialPortControlTableEntry Index serialPortControlchassisIndex serialPortControlIndex Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 1 Description Defines index one based of this chassis Syntax DellObjectRange Access read only Serial Port Control Index Name serialPortControliIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 2 Description Defines the index one based of the serial port in this chassis Syntax DellObjectRange Access read only Serial Port Control Capabilities Unique Name serialPortControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 3 Description Defines the capabilities of the serial port Syntax DellSerialPortControlCapabilitiesUnique See Table 16 15 Access Read only Serial Port Control Settings Unique Name serialPortControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 4 Description Defines the settings of the serial port Syntax DellSerialPortControlSettingsUnique See Table 16 16 BIOS Setup Control Group 399 Name serialPortControlSettingsUnique Access Read only Serial Port Control Status Name serialPortControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 5 Description
248. ce Group Cache Device Current Type Name Object ID Description Syntax Access cacheDeviceCurrentTyp 1 3 6 1 4 1 674 10892 1 1100 40 1 20 Defines the current type of SRAM for the cache device DellCacheDeviceSRAMType See Table 13 14 Read only Memory Device Table Name Object ID Description Syntax Access memoryDeviceTabl 1 3 6 1 4 1 674 10892 1 1100 50 Defines the Memory Device Table SEQUENCE OF MemoryDevice TableEntry Not accessible Memory Device Table Entry Name Object ID Description Syntax Access Index memoryDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 50 1 Defines the Memory Device Table entry MemoryDeviceTableEntry Not accessible memoryDevicechassisIndex memoryDeviceIndex Memory Device Chassis Index Name Object ID Description Syntax Access memoryDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 50 1 1 Defines the index one based of this chassis DellObjectRange Read only Device Group 281 Memory Device Index Name Object ID Description Syntax Access memoryDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 50 1 2 Defines the index of the memory device in this chassis DellObjectRange Read only Memory Device State Capabilities Name Object ID Description Syntax Access memoryDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 50 1 3 Defines the capabilities of the memory device DellStateCapabilities Read only Memory D
249. ce Group Memory Device Uncorrectable Memory Event Count K NOTE Memory Device Failure Modes has now replaced this attribute Memory Device Uncorrectable Memory Event Count should no longer be used If you use the Memory Device Uncorrectable Memory Event Count attribute the value returned is always zero and using the attribute will have no effect Name Object ID Description Syntax Access memoryDeviceMultiBitErrorCount 1 3 6 1 4 1 674 10892 1 1100 50 1 19 Defines the total number of Uncorrectable Memory Events detected by the memory device DellSigned32BitRange Read only Memory Device Failure Modes Name Object ID Description Syntax Access memoryDeviceFailureModes 1 3 6 1 4 1 674 10892 1 1100 50 1 20 Defines the failure modes of the memory device when the memoryDeviceStatus attribute is not OK It is a bit field that can be used to report more than one type of failure mode by using a combination of the defined bit masks DellMemoryDeviceFailureModes Read only Memory Device Manufacturer Name Name Object ID Description Syntax Access memoryDeviceManufacturerName 1 3 6 1 4 1 674 10892 1 1100 50 1 21 Defines the manufacturer of the memory device DellString Read only Device Group 287 Memory Device Part Number Name Name Object ID Description Syntax Access memoryDevicePartNumberName 1 3 6 1 4 1 674 10892 1 1100 50 1 22 Defines the manufacturer s part number
250. cess enclosureAlarm 1 3 6 1 4 1 674 10893 1 20 130 3 1 20 Identifies the current status of the enclosure s alarm PowerVault 220S and PowerVault 221S only Possible values 1 Disabled 2 Enabled Integer Read only Storage Management Group 581 Enclosure Backplane Part Number Name enclosureBackplanePartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 21 Description Identifies the part number of the enclosure s backplane Syntax Integer Access Read only Enclosure SCSI ID Name enclosureSCSIID Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 22 Description Identifies the SCSI ID of the controller to which this enclosure is attached Syntax Integer Access Read only Enclosure Roll Up Status Name enclosureRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 23 Description Identifies the severity of the enclosure state This is the combined status of the enclosure and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 582 Storage Management Group Enclosure Component Status Name Object ID Description Syntax Access enclosureComponent Status 1 3 6 1 4 1 674 10893 1 20 130 3 1 24 The status of the enclosure itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus
251. cess processorDeviceStatusChassisIndex 1 3 6 1 4 1 674 10892 1 1100 32 1 1 Defines the index one based of the associated chassis DellObjectRange Read only Device Group 273 Processor Device Status Index Name Object ID Description Syntax Access processorDeviceStatusIndex 1 3 6 1 4 1 674 10892 1 1100 32 1 2 Defines the index one based of the processor device status probe DellObjectRange Read only Processor Device Status State Capabilities Name Object ID Description Syntax Access processorDeviceStatusStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 32 1 3 Defines the state capabilities of the processor device status probe DellStateCapabilities Read only Processor Device Status State Settings Name Object ID Description Syntax Access processorDeviceStatusStateSettings 1 3 6 1 4 1 674 10892 1 1100 32 1 4 Defines the state settings of the processor device status probe DellStateSettings Read write Processor Device Status Status Name Object ID Description Syntax Access 274 processorDeviceStatusStatus 1 3 6 1 4 1 674 10892 1 1100 32 1 5 Defines the status of the processor device status probe This status will be joined into the processorDeviceStatus attribute DellStatus Read only Device Group Processor Device Status Reading Name Object ID Description Syntax Access processorDeviceStatusReading 1 3 6 1 4 1 674 10892 1 1100 32 1 6 Defines
252. cess Read only BIOS Setup Control Group 387 BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 16 Description Defines the status of speaker control Syntax DellStatus Access Read only BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 17 Description Defines the setup BIOS name of the speaker control Syntax DellString Access Read only BIOS Setup Control NIF Wakeup on LAN Control Capabilities Unique Name bSUCnIFwakeonLanControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 18 Description Defines the defines the capabilities of the network interface function NIF Wakeup on LAN Syntax DellNIFwakeonLanControlCapabilitiesUnique SeeTable 16 4 Access Read only BIOS Setup Control NIF Wakeup on LAN Control Settings Unique Name bSUCnIFwakeonLanControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 19 Description Defines the state of the NIF Wakeup on LAN Syntax DelINIFwakeonLanControlSettingsUnique See Table 16 4 Access Read only 388 BIOS Setup Control Group BIOS Setup Control NIF Wakeup on LAN Control Status Name bSUCnIFwakeonLanControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 20 Description Defines the status of the NIF Wakeup on LAN Syntax DellStatus Access Read only BIOS Setup Control NIF Wakeup on LAN Control Name Name bSUCnIFwakeonLa
253. cess Read only Storage Management Group 545 Agent Vendor Name agentVendor Object ID 1 3 6 1 4 1 674 10893 1 20 100 3 Description Identifies the name of the management software manufacturer Syntax DisplayString Access Read only Agent Version Name agentVersion Object ID 1 3 6 1 4 1 674 10893 1 20 100 4 Description This entry is obsolete Refer to softwareVersion Syntax DisplayString Access Read only Global Data Group The Global Data Management Information Base MIB Group defines the properties that identify status information about the system that the Storage Management software is managing and about the Storage Management SNMP agent Agent System Global Status Name agentSystemGlobalStatus Object ID 1 3 6 1 4 1 674 10893 1 20 110 1 Description This entry is obsolete Use the value agentGlobalSystemStatus Syntax Integer Access Read only 546 Storage Management Group Agent Last Global Status Name agentLastGlobalStatus Object ID 1 3 6 1 4 1 674 10893 1 20 110 2 Description This entry is obsolete Use the value agentLastGlobalSystemStatus Syntax Integer Access Read only Agent Time Stamp Name agentTimeStamp Object ID 1 3 6 1 4 1 674 10893 1 20 110 3 Description Identifies the last time that the agent values have been updated Universal time in sec since UTC 1 1 70 Syntax Integer Access Read only Agent Get Timeout Name agentGet Timeout Object ID 1 3 6 1 4 1 674 10893 1 20 110 4
254. cessTypelIsERA 4 The remote access type is ERA Table 19 2 Remote Access Control Capabilities Variable Name De 1 1RemoteAccessControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no control capabilities unknownCapabilities 1 The remote access hardware control capabilities are unknown 500 Remote Access Group Table 19 2 Remote Access Control Capabilities continued Variable Name De 1 1RemoteAccessControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value logResetCapable 2 The remote access hardware can reset its integrated logs hardResetCapable 4 The remote access hardware can perform a hard reset softResetCapable 8 The remote access hardware can perform a soft reset gracefulResetCapable 16 The remote access hardware can gracefully shut down and perform a soft reset defaultConfigResetCapable 32 The remote access hardware can reset to its default settings shut downCapable 64 The remote access hardware can shut down Table 19 3 Remote Access Control Settings Variable Name De 1 1RemoteAccessControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 T he remote access hardware has no control settings unknown 1 The remote access hardware control settings are
255. cessor Device Table 265 variable values 317 Device removed from system 722 E Event Log viewing entries 738 G Global Data Group 546 Introduction Server Administrator Change Management MIB 28 Server Administrator Instrumentation MIB 23 Server Administrator Remote Access MIB 25 Server Administrator Storage Management MIB 27 Inventory 657 Inventory Group 657 L Local Response Agent Group LRA Action Table 422 LRA Global Settings 419 LRA Global Settings Table 420 variable values 424 Local Response Agent Group tables 419 Logical Devices Group 641 Memory device correction rate crossed a warning threshold 716 Memory device ECC Correctable error count crossed a warning threshold 716 Memory Group Physical Memory Tables 359 variable values 367 373 Memory Group Variable Values 377 MIB minor version number 44 MIB Major Version Number 43 0 Operating System Group 663 Memory Table 123 Operating System Table 121 Operating System Memory Table 123 P Physical Devices Group 552 Physical Memory Card Table 374 Pluggable Device Traps 721 Port Group Keyboard Port Table 228 Memory Device Port Table 234 Monitor Port Table 237 Parallel Port Table 242 Pointing Port Table 225 Processor Port Table 231 Serial Port Table 246 Small Computer System Interface Port Table 240 variable values 253 Power Group AC Power Cord Table 169 AC Powe
256. chassisNMIButtonControlSettingsUnique 1 3 6 1 4 1 674 10892 1 300 10 1 45 Defines the current reading and allows setting of the NMI button control hardware DelINMIButtonControlSettings See Table 5 19 Read write Chassis System Properties Name Object ID Description Syntax Access chassisSystemProperties 1 3 6 1 4 1 674 10892 1 300 10 1 46 Defines the properties of the system DellSystemProperties See Table 5 20 Read only Chassis Information Group 83 Chassis System Revision Number Name chassisSystemRevisionNumber Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 47 Description Defines the revision number of the system where zero indicates the original version of the system The revision number is not available on all systems Syntax DellUnsigned8BitRange Access Read only Chassis System Revision Name Name chassisSystemRevisionName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 48 Description Defines the revision name of the system if applicable Syntax DellString Access Read only UUID Table These objects comprise the server administrator definitions for the Universal Unique Identifier UUID Name uUIDTable Object ID 1 3 6 1 4 1 674 10892 1 300 20 Description Defines the UUID table Syntax SEQUENCE OF UUIDTableEntry Access Not accessible 84 Chassis Information Group UUID Table Entry Name uUIDTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 Description Defines the UUID table entry
257. cription Defines the Remote Flash BIOS Table entry Syntax RemoteFlashBIOSTableEntry Access Not accessible Index remoteFlashBIOSchassisIndex remoteFlashBIOSIndex Remote Flash BIOS Group 219 Remote Flash BIOS Chassis Index Name remoteF lashBlOSchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Remote Flash BIOS Index Name remoteF lashBIOSIndex Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 2 Description Defines the index to the remote BIOS update hardware on this system Syntax DellObjectRange Access Read only Remote Flash BIOS State Capabilities Unique Name remoteFlashBIOSStateCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 3 Description Defines the capabilities of the remote BIOS update hardware on this system Syntax DellRemoteFlashBIOSStateCapabilitiesUnique See Table 11 1 Access Read only Remote Flash BIOS State Settings Unique Name remoteF lashBlOSStateSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 4 Description Defines the state and settings of the remote BIOS update hardware on this system Syntax DellRemoteFlashBIOSStateSettingsUnique See Table 11 2 Access Read write 220 Remote Flash BIOS Group Remote Flash BIOS Status Name remoteFlashBIOSStatus Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 5 Description Defines the status of the remote BIOS update hardware
258. cription Indicates the week 1 through 53 in which this disk was manufactured Syntax DisplayString Access Read only 596 Storage Management Group Array Disk Manufacture Year Name arrayDiskManufactureYear Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 34 Description Indicates the four digit year in which this disk was manufactured Syntax DisplayString Access Read only Array Disk Media Type Name arrayDiskMediaType Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 35 Description Indicates the media type of the array disk Syntax INTEGER Access Read only Array Disk Enclosure Connection Table This table describes the connections among array disks their enclosure and their associated controller For each object in the table its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found K NOTE Only array disks that are part of an enclosure will be listed in this table Backplanes are considered enclosures by Storage Management The following object sets up the Array Disk Enclosure Connection Table Name arrayDiskEnclosureConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 Description Defines the array disk enclosure connection table Syntax SEQUENCE OF ArrayDiskEnclosureConnectionEntry Access Not accessible Storage Management Group 597 Array Disk Enclosure Connection Entry Name Object ID Description Syntax Acce
259. ct ID 1 3 6 1 4 1 674 10892 1 1100 30 1 15 Description Defines the processor upgrade information for the processor device Syntax DellProcessorUpgradeInformation See Table 13 5 Access Read only Processor Device Version Name Name processorDeviceVersionName Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 16 Description Defines the version name of the processor device Syntax DellString Access Read only Device Group 269 Processor Device Core Count Name processorDeviceCoreCount Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 17 Description Defines the number of processor cores detected for the processor device Syntax DellUnsigned32BitRange Access Read only Processor Device Core Enabled Count Name processorDeviceCoreEnabledCount Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 18 Description Defines the number of processor cores enabled for the processor device Syntax DellUnsigned32BitRange Access Read only Processor Device Thread Count Name processorDeviceThreadCount Object ID 1 3 6 1 4 1 674 10892 1 1100 30 1 19 Description Defines the number of processor threads detected for the processor device Syntax DellUnsigned32BitRange Access Read only 270 Device Group Processor Device Characteristics Name Object ID Description Syntax Access processorDeviceCharacteristics 1 3 6 1 4 1 674 10892 1 1100 30 1 20 This attribute defines characteristics of the processor device This attribute
260. ctName Name DRsProductName Object ID 1 3 6 1 4 1 674 10892 2 1 1 1 Description Defines the product name of a chassis management controller Syntax DellString Access Read only DRsProductShortName Name DRsProductShortName Object ID 1 3 6 1 4 1 674 10892 2 1 1 2 Description Defines the short product name of a chassis management controller Syntax DellString Access Read only Dell RAC Out of Band Group 667 DRsProductDescription Name DRsProductDescription Object ID 1 3 6 1 4 1 674 10892 2 1 1 3 Description Defines the product description of a chassis management controller Syntax DellString Access Read only DRsProductManufacturer Name DRsProductManufacturer Object ID 1 3 6 1 4 1 674 10892 2 1 1 4 Description Defines the product manufacturer of a chassis management controller Syntax DellString Access Read only DRsProductVersion Name DRsProductVersion Object ID 1 3 6 1 4 1 674 10892 2 1 1 5 Description Defines the product version of a chassis management controller Syntax DellString Access Read only DRsChassisServiceTag Name DRsChassisServiceTag Object ID 1 3 6 1 4 1 674 10892 2 1 1 6 Description Defines the Service Tag of the chassis Syntax DellString Access Read only 668 Dell RAC Out of Band Group DRsProductURL Name Object ID Description Syntax Access DrsProductURL 1 3 6 1 4 1 674 10892 2 1 1 7 Defines the out of band UI URL of a chassis management controller DellStri
261. ctRange Read only ideControlIndex 1 3 6 1 4 1 674 10892 1 1400 60 1 2 Defines the index one based of the IDE controller in this chassis DellObjectRange Read only IDE Control Capabilities Unique Name Object ID Description Syntax Access ideControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1400 60 1 3 Defines the capabilities of the IDE controller DellideControlCapabilitiesUnique See Table 16 17 Read only BIOS Setup Control Group 403 IDE Control Settings Unique Name ideControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 60 1 4 Description Defines the settings for the IDE controller Syntax DellideControlCapabilitiesUnique See Table 16 17 Access Read only IDE Control Status Name ideControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 60 1 5 Description Defines the status for the IDE controller Syntax DellStatus Access Read only IDE Control Name Name ideControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 60 1 6 Description Defines the setup BIOS name for the IDE controller Syntax DellStatus Access Read only Diskette Control Table Name disketteControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 70 Description Defines the Diskette Control Table Syntax DisketteControlTableEntry Access Not accessible 404 BIOS Setup Control Group Diskette Control Table Entry Name Object ID Description Syntax Access Index disketteControlTableEntry 1 3 6 1 4 1 674 10892
262. d Syntax DellStatus Access Read only Baseboard Feature Flags Name baseBoardFeatureFlags Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 6 Description Defines the features of the baseboard Syntax DellBaseBoardFeatureF lags Access Read only Baseboard Type Name baseBoardType Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 7 Description Defines the type of the baseboard Syntax DellBaseBoard Type Access Read only 104 Chassis Information Group Baseboard Type Name Name Object ID Description Syntax Access baseBoardTypeName 1 3 6 1 4 1 674 10892 1 300 80 1 8 Defines the name of the type of baseboard DellString Read only Baseboard Location Name Name Object ID Description Syntax Access baseBoardLocationName 1 3 6 1 4 1 674 10892 1 300 80 1 9 Defines the location name of the baseboard DellString Read only Baseboard Manufacturer Name Name Object ID Description Syntax Access baseBoardManufacturerName 1 3 6 1 4 1 674 10892 1 300 80 1 10 Defines the baseboard manufacturer s name DellString Read only Baseboard Product Name Name Object ID Description Syntax Access baseBoardProductName 1 3 6 1 4 1 674 10892 1 300 80 1 11 Defines the baseboard product s name DellString Read only Chassis Information Group 105 Baseboard Version Name Name baseBoardVersionName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 12 Description Defines the baseboard version name Syntax DellSt
263. d as a binary octet string Each byte of the octet string represents the state of a specific power supply The first byte returned represents the state of the first power supply the second byte returned represents the state of the second power supply and so on The bytes have the same definition type as DellStateSettings Syntax OCTET STRING SIZE 1 128 Access Read only System State Power Supply Status Combined Name systemStatePowerSupplyStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 9 Description Defines the status of all power supplies in this chassis Syntax DellStatus Access Read only System State Power Supply Status Details Name systemStatePowerSupplyStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 10 Description Defines the status of all power supplies in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific power supply The first byte returned represents the status of the first power supply the second byte returned represents the status of the second power supply and so on The bytes have the same definition type as DellStatus Syntax OCTET STRING SIZE 1 128 Access Read only 54 System State Group System State Voltage State Details Name systemStateVoltageStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 11 Description Defines the state of all voltage probes in this chassis The results are returned a
264. d only Storage Management Group 601 Array Disk Channel Connection Channel Name Name arrayDiskChannelConnectionChannelName Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 4 Description Identifies the name of the channel as represented in Storage Management to which is array disk is connected Syntax DisplayString Access Read only Array Disk Channel Connection Channel Number Name arrayDiskChannelConnectionChannelNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 5 Description Identifies the instance number of the channel in the channelTable to which this array disk is connected Syntax Integer Access Read only Array Disk Channel Connection Controller Name Name arrayDiskChannelConnectionControllerName Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 6 Description Identifies the name of the controller as represented in Storage Management to which this array disk is connected Syntax DisplayString Access Read only Array Disk Channel Connection Controller Number Name arrayDiskChannelConnectionControllerNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 7 Description Identifies the instance number in the controllerTable of the controller to which this array disk is connected Syntax Integer Access Read only 602 Storage Management Group Fan Table This table describes available properties for each fan on the managed system The following object sets up the Fan Table Name Object ID Description Syntax
265. d to the numeric pager for this remote access user DisplayString SIZE 0 31 Read write Remote Access Group 481 Remote User Admin Pager Numeric Hang up Delay Name remot eUserAdminPagerNumericHangupDelay Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 17 Description Defines the numeric pager hang up delay for this remote access user Syntax DellUnsigned32BitRange Access Read write Remote User Admin Pager Alpha Phone Number Name Name remot eUserAdminPagerAlphaPhoneNumberName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 18 Description Defines the alphanumeric pager phone number for this remote access user Syntax DisplayString SIZE 0 95 Access Read write Remote User Admin Pager Alpha Protocol Name remoteUserAdminPagerAlphaProtocol Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 19 Description Defines the protocol used by the alphanumeric pager provider for this remote access user Syntax DellRemoteUserAdminAlphaProtocol Type See Table 19 16 Access Read write Remote User Admin Pager Alpha Baud Rate Name remot eUserAdminPagerAlphaBaudRate Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 20 Description Defines the baud rate used by the alphanumeric pager provider for this remote access user Syntax DellRemoteUserAdminAlphaBaudType See Table 19 17 Access Read write 482 Remote Access Group Remote User Admin Pager Alpha Custom Message Name Name remot eUserAdminPagerAlphaCustomMessageName Object ID 1 3
266. dant settings of the physical memory DellPhysicalMemoryConfigRedundantSettings Read write Physical Memory Logging Table This table defines the conditions for logging system memory events The following object sets up the Physical Memory Logging Table Name Object ID Description Syntax Access physicalMemoryLoggingTable 1 3 6 1 4 1 674 10892 1 1300 40 Defines the Physical Memory Logging Table SEQUENCE OF PhysicalMemoryLogging TableEntry Not accessible Memory Group _ 369 Physical Memory Logging Table Entry Syntax Access Index Name Object ID Description physicalMemoryLoggingTableEntry 1 3 6 1 4 1 674 10892 1 1300 40 1 Defines the Physical Memory Logging Table entry PhysicalMemoryLoggingTableEntry Not accessible physicalMemoryLoggingChassisIndex physicalMemoryLoggingIndex Physical Memory Logging Chassis Index Name Object ID Description Syntax Access physicalMemoryLoggingChassisIndex 1 3 6 1 4 1 674 10892 1 1300 40 1 1 Defines the index one based of the chassis associated with the physical memory logging DellObjectRange Read only Physical Memory Logging Index Name Object ID Description Syntax Access physicalMemoryLoggingIndex 1 3 6 1 4 1 674 10892 1 1300 40 1 2 Defines the index one based of the physical memory logging DellObjectRange Read only Physical Memory Logging Capabilities Name Object ID Description Syntax Access 370 physicalMe
267. dapter Index Name remoteDialOutAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 2 Description Defines the index one based of the remote access hardware that supports this remote access dial out functionality Syntax DellObjectRange Access Read only Remote Dial Out Dial Out Index Name remoteDialOutDialOut Index Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 3 Description Defines the index one based of this remote access dial out functionality Syntax DellObjectRange Access Read only Remote Dial Out State Capabilities Name remoteDialOutStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 4 Description Defines the state capabilities of this remote access dial out functionality Syntax DellRemoteDialOutStateCapabilities See Table 19 27 Access Read only Remote Dial Out State Settings Name remoteDialOutStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 5 Description Defines the state settings of this remote access dial out functionality Syntax DellRemoteDialOutStateSettings See Table 19 28 Access Read write 498 Remote Access Group Remote Dial Out Status Name Object ID Description Syntax Access remoteDialOutStatus 1 3 6 1 4 1 674 10892 1 1700 60 1 6 Defines the status of this remote access dial out functionality DellStatus Read only Remote Dial Out IP Address Name Object ID Description Syntax Access remoteDialOutIPAddress 1 3 6 1 4 1 674 10892 1 1700
268. deviceTypeIsATrackBall 4 Device type is a track ball deviceTypelIsATrackPoint 5 Device type is a track point deviceTypeIsAGlidePoint 6 Device type is a glide point deviceTypeIsATouchPad 7 Device type is a touch pad Table 13 12 Cache Device Associativity Variable Name De 1 1CacheDeviceAssociativity Data Type Integer Possible Data Values Meaning of Data Value deviceAssociativityIsOther 1 Device associativity is not one of the following deviceAssociativityIsUnknown 2 Device associativity is unknown deviceAssociativityIsDirectMapped 3 Device is direct mapped deviceAssociativityIsTwoWaySetAsso Device is two way set ciative 4 associative deviceAssociativityIsFourWaySetAsso Device is four way set ciative 5 associative deviceAssociativityIsFullyAssociative Device is fully associative 6 deviceAssociativityIsEightWaySetAsso Device is eight way set ciative 7 associative Device Group 333 Table 13 12 Cache Device Associativity continued Variable Name De 1 1CacheDeviceAssociativity Data Type Integer Possible Data Values Meaning of Data Value deviceAssocia Associative 8 tivityIsSixteen WaySet Device is sixteen way set associative deviceAssocia lative 9 tivityIsl2WaySe tAssoc Device is 12 way Set Associative deviceAssocia lative 10 tivityIs24WaySe tAssoc Device is 24 way Set Associative de
269. dex Object ID 1 3 6 1 4 1 674 10892 1 1600 110 1 2 Description Defines the index one based of the system s trouble ticket information Syntax DellObjectRange Access Read only COO Trouble Ticket State Name cooTroubleTicketState Object ID 1 3 6 1 4 1 674 10892 1 1600 110 1 3 Description Defines the trouble ticket information state for this system Syntax DellStateSettings Access Read only Cost of Ownership Group 457 COO Trouble Ticket Support Information Index Reference Name cooTroubleTicketSupportInformationIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1600 110 1 4 Description Defines the support information index that references the trouble ticket Syntax DellUnsigned32BitRange Access Read write COO Trouble Ticket Number Name Name cooTroubleTicketNumberNam Object ID 1 3 6 1 4 1 674 10892 1 1600 110 1 5 Description Defines the trouble ticket number for this system Syntax DellCostofOwnershipString Access Read write Cost of Ownership Variable Values This section includes definitions for server administrator specific variable values used in this section Table 18 1 COO Ownership Codes Variable Name Del 1CooOwnershipCodes Data Type Integer Possible Data Values Meaning of Data Value other 1 The ownership code is not one of following unknown 2 The ownership code is unknown owned 3 The ownership code is owned leased 4 The ownership code is leased ren
270. dictive Failure Warning 2715520 Battery Low Predictive Failure Informational Cleared 2715393 Battery Failure Critical 2715521 Battery Failure Cleared Informational 487169 CPU Thermal Trip Over Temperatur Critical Shutdown 487297 CPU Thermal Trip Over Temperatur Informational Shutdown Cleared 487168 CPU Internal Error Critical 487296 CPU Internal Error Cleared Informational 487173 CPU Configuration Error Critical 487301 CPU Configuration Error Cleared Informational 487175 CPU Presence Processor Presence Informational detected 487303 CPU Not Present Processor Not Present Critical 487170 CPU BIST Built In Self Test Failure Critical 487298 CPU BIST Built In Self Test Failure Informational Cleared 487176 CPU Disabled Processor Disabled Critical 487304 CPU Enabled Processor Enabled Informational Traps 733 Table 26 20 BMC Traps continued Trap ID Description Severity 487178 CPU Throttle Processor Speed Reduced Warning 487306 CPU Throttle Cleared Normal Processor Informational Speed 527106 Power Supply Redundancy Degraded Warning 527105 Power Supply Redundancy Lost Critical 527104 Power Supply Redundancy Has Returned to Informational Normal 552704 Power Supply Inserted Informational 552832 Power Supply Removed Warning 552705 Power Supply Failure Critical 552833 Power Supply Failure Cleared Informational 552706 Power Supply Warning Warning 55283
271. dministrative privileges can read but not modify the value of a variable read only or can both read and modify the value of a variable read write 32 Introduction Frequently Used Terms in Variable Names The following terms are frequently used in the name of a MIB variable Capability refers to the actions an object can perform or to actions that can be taken by the object Hot pluggable is an example of a capability If a card is hot pluggable it can be replaced while a system is running Capability settings refer to the capabilities of the object that the user can select from and activate if desired Capability settings allow users of the server administrator to predetermine how an object will behave under specific conditions Settings are the conditions of a manageable object that determine what happens when a certain value is detected in a component For example a user can set the upper critical threshold of a temperature probe to 75 degrees Celsius If the probe reaches that temperature the setting causes an alert to be sent to the management console Some settings when reached can trigger a system shutdown or other response to prevent damage to the system State refers to the condition of an object that has more than one condition For example an object may be in a not ready or in an enabled state Status refers to the health of an object or how the object is functioning For example the status of a temperature probe tha
272. dows Advanced Server Limited Edition 64 bit operating system Windows Net 64 on a Dell PowerEdge 7150 The following MIB tables define objects and relationships or connections among the objects in the Logical Devices Group e Virtual Disk Table describes available properties for each virtual disk on the managed system e Array Disk Logical Connection Table describes the connections between array disks the virtual disk to which they belong and their associated logical disk For each object in the table its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found Virtual Disk Table This table describes available properties for each virtual disk on the managed system The following object sets up the Virtual Disk Table Name virtualDiskTable Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 Description Defines the virtual disk table Syntax SEQUENCE OF VirtualDiskEntry Access Not accessible Storage Management Group 641 Virtual Disk Entry Name virtualDiskEntry Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 Description Defines the virtual disk table entry Syntax VirtualDiskEntry Access Not accessible Index virtual DiskNumber Virtual Disk Number Name virtualDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 1 Description Identifies the instance number of the virtual disk entry Syntax Integer Access Read only Vi
273. dress other 4 Other protocol used to obtain IP address 534 Baseboard Management Controller Group Table 21 6 BMC Management Controller Type Variable Name De 1 1ManagementControllerType Data Type Integer Possible Data Values Meaning of Data Value legacyBMC 0 Controller type is legacy Baseboard Management Controller 1DRAC 8 Controller type is iDRAC iDRAC6 10 Controller type is Integrated Dell Remote Access Controller 6 iDRAC6Modular 11 Controller type is Integrated Dell Remote Access Controller 6 Modular iDRAC6BMC 13 Controller type is Integrated Dell Remote Access Controller 6 BMC mode Baseboard Management Controller Group 535 536 Baseboard Management Controller Group Field Replaceable Unit Group A field replaceable unit FRU is a part that can be removed and replaced without having to send the system to a repair facility The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system Field Replaceable Unit Group Tables The objects in the FRU group define information such as manufacturer serial number part number and revision for field replaceable units The following MIB tables define the FRU group Field Replaceable Unit Table Name fruTable Object ID 1 3 6 1 4 1 674 10892 1 2000 10 Description Defines the Field Replaceable Unit table Syntax SEQUENCE OF
274. e Access Read only Cooling Unit State Capabilities Name coolingUnitStateCapabilties Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 3 Description Defines the capabilities of the cooling unit Syntax DellStateCapabilities Access Read only Cooling Unit State Settings Name coolingUnitStateSettings Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 4 Description Defines the state and settings of the cooling unit Syntax DellStateSettings Access Read write 198 Thermal Group Cooling Unit Redundancy Status Name Object ID Description Syntax Access coolingUnitRedundancyStatus 1 3 6 1 4 1 674 10892 1 700 10 1 5 Defines the redundancy status of the cooling unit DellStatusRedundancy Read only Cooling Device Count For Redundancy Name Object ID Description Syntax Access coolingDeviceCountForRedundancy 1 3 6 1 4 1 674 10892 1 700 10 1 6 Defines the total number of cooling devices required for this cooling unit to have redundancy DellObjectRange Read only Cooling Unit Name Name Object ID Description Syntax Access coolingUnitName 1 3 6 1 4 1 674 10892 1 700 10 1 7 Defines the cooling unit name in this chassis DellString Read only Cooling Unit Status Name Object ID Description Syntax Access coolingUnitStatus 1 3 6 1 4 1 674 10892 1 700 10 1 8 Defines the status of the cooling unit in this chassis DellStatus Read only Thermal Group 199 Cooling Device Table Name coo
275. e Name powerSupplyName Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 2 Description Identifies the power supply s name as represented in Storage Management Syntax DisplayString Access Read only Power Supply Vendor Name powerSupplyVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 3 Description Identifies the power supply s re seller s name Syntax DisplayString Access Read only 612 Storage Management Group Power Supply State Name Object ID Description powerSupplyState 1 3 6 1 4 1 674 10893 1 20 130 9 1 4 Identifies the current state of the power supply Possible states 0 Unknown 1 Ready 2 Failed 5 Not Installed 6 Degraded 11 Removed Syntax Integer Access Read only Power Supply Severity Name powerSupplySeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 5 Description Syntax Access This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Integer Read only Power Supply 1 Part Number Name Object ID Description Syntax Access powerSupplylPartNumber 1 3 6 1 4 1 674 10893 1 20 130 9 1 6 Identifies the part number of the power supply of the enclosure DisplayString Read only Storage Management Group 613 Power Supply 2 Part Number Name powerSupply2PartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 7 Description This entry is obsolete This setting is not supported by power supplies managed under Sto
276. e 47 name 46 48 preferred protocol 47 supported protocol 47 version number name 46 T Thermal Group Cooling Device Table 199 Cooling Unit Table 197 Temperature Probe Table 205 variable values 211 trap variables 692 current status 693 data 693 message 692 previous status 693 system 692 table index OID 692 traps 699 AC power cord traps 717 amperage probe traps 708 chassis intrusion traps 710 cooling device traps 704 fan enclosure traps 716 hardware log traps 718 memory device traps 715 miscellaneous traps 700 power supply traps 713 redundancy unit traps 711 temperature probe traps 702 understanding the trap descriptions 694 understanding trap severity 698 voltage probe traps 706 U User Security Table 215 219 V variable names capability 33 settings 33 state 33 status 33 Viewing SNMP traps 741 Index 759 760 Index
277. e continued Variable Name De 1 1ResourceOwnerInterfaceTyp Data Type Integer Possible Data Values Meaning of Data Value typeIsEISA 5 The interface type is an Extended Industry Standard Architecture EISA bus typeIsMCA 6 The interface type is a microchannel architecture MCA bus typeIsTurboChannel 7 The interface type is a turbo channel bus Table 7 3 Resource Share Disposition Variable Name De 1 1ResourceShareDisposition Data Type Integer Possible Data Values Meaning of Data Value shareIsOther 1 The share disposition is not one of the following sharelIsUnknown 2 The share disposition is unknown not known or not monitored shareIlsDeviceExclusive 3 The share disposition is device exclusive shareIsDriverExclusive 4 The share disposition is driver exclusive sharelIsShared 5 The share disposition is shared Table 7 4 Resource Memory Flags Variable Name De 1 1ResourceMemoryFlags Data Type Integer Possible Data Values Meaning of Data Value memoryIsReadOn1ly 1 The resource memory is read only memoryIsWriteOnly 2 The resource memory is write only memoryIsPreFetchable 4 The resource memory is prefetchable memoryIsCombinedWritable 8 The resource memory is read write memoryIsF24 16 The resource memory is F24 System Resource Group 145 Table 7 5 Resource Interrupt Type Variable Name
278. e DMA transfer width is 32 bits dmaTransferWidthIs64Bits 6 The DMA transfer width is 64 bits dmaTransferWidthIs128Bits 7 The DMA transfer width is 128 bits System Resource Group 147 148 System Resource Group Power Group The Power Group provides information about power units a group of power supplies in a system chassis power supplies and voltage and amperage probes Power Group Tables The following management information base MIB tables define objects for the Power Group e Power Unit Table e Power Supply Table e Voltage Probe Table e Amperage Probe Table e AC Power Switch Table e AC Power Cord Table e Battery Table e Power Usage Table e Power Profile Table Power Unit Table Name powerUnitTable Object ID 1 3 6 1 4 1 674 10892 1 600 10 Description Defines the Power Unit Table Syntax PowerUnit TableEntry Access Not accessible Power Group 149 Power Unit Table Entry Name powerUnitTableEntry Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 Description Defines the Power Unit Table entry Syntax DellObjectRange Access Read only Index powerUnitchassisIndex powerUnitIndex Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Power Unit Index Name powerUnit Index Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 2 Description Defines the index o
279. e entry ParallelPort TableEntry Not accessible parallelPortchassisIndex parallelPortIndex Parallel Port Chassis Index Name Object ID Description Syntax Access parallelPortchassisIndex 1 3 6 1 4 1 674 10892 1 1000 70 1 1 Defines the index one based of this chassis DellObjectRange Read only Parallel Port Index Name Object ID Description Syntax Access parallelPortIndex 1 3 6 1 4 1 674 10892 1 1000 70 1 2 Defines the index of the parallel ports in this chassis DellObjectRange Read only Parallel Port State Capabilities Name Object ID Description Syntax Access parallelPortStateCapabilities 1 3 6 1 4 1 674 10892 1 1000 70 1 3 Defines the capabilities of the parallel port DellStateSettings Read write Port Group 243 Parallel Port State Settings Name parallelPortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 4 Description Defines the state and settings of the parallel port Syntax DellStateSettings Access Read write Parallel Port Status Name parallelPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 5 Description Defines the status of the parallel port Syntax DellStatus Access Read only Parallel Port Security State Name DellPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 6 Description Defines the security state of the parallel port Syntax DellStatus Access Read only Parallel Port Connector Type Name parallelPortConnectorType Objec
280. e fanlPartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 12 Description Identifies the part number of the fan in the enclosure Syntax DisplayString Access Read only 606 Storage Management Group Fan 2 Part Number Name Object ID Description Syntax Access fan2PartNumber 1 3 6 1 4 1 674 10893 1 20 130 7 1 13 This entry is obsolete This setting is not supported by fans managed under Storage Management DisplayString Read only Fan Roll Up Status Name Object ID Description Syntax Access fanRollUpStatus 1 3 6 1 4 1 674 10893 1 20 130 7 1 14 Severity of the fan state This is the combined status of the fan and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Storage Management Group 607 608 Fan Component Status Name Object ID Description Syntax Access Fan Nexus ID Name Object ID Description Syntax Access Fan Revision Name Object ID Description Syntax Access fanComponent Status 1 3 6 1 4 1 674 10893 1 20 130 7 1 15 The status of the fan itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only fanNexusID 1 3 6 1 4 1 674 10893 1 20 130 7 1 16 Durable unique ID for this fan DisplayString Read only fanRevision 1 3 6 1 4 1 674
281. e is voltageProbeTypelsDiscrete the value returned for this attribute is the discrete reading for the probe Syntax DellVoltageDiscreteReading Access Read only Amperage Probe Table Name amperageProbeTabl Object ID 1 3 6 1 4 1 674 10892 1 600 30 Description Defines the Amperage Probe Table Syntax SEQUENCE OF AmperageProbeTableEntry Access Not accessible Amperage Probe Table Entry Name Object ID Description Syntax Access Index amperageProbeTableEntry 1 3 6 1 4 1 674 10892 1 600 30 1 Defines the Amperage Probe Table entry AmperageProbeTableEntry Not accessible amperageProbechassisIndex amperageProbeIndex PowerGroup_ 161 Amperage Probe Chassis Index Name amperageProbechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Amperage Probe Index Name amperageProbeIndex Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 2 Description Defines the index of amperage probes in this chassis Syntax DellObjectRange Access Read only Amperage Probe State Capabilities Name amperageProbeStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 3 Description Defines the capabilities of the amperage probe Syntax DellStateCapabilities Access Read only Amperage Probe State Settings Name amperageProbeStateSettings Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 4 Description Defines the
282. e was Lost Previous state was lt State gt Specifies the previous state of the sensor for example Previous state was OK Normal Processor sensor status lt status gt Specifies the status of the processor sensor for example Processor sensor status Configuration error Redundancy unit lt Redundancy location in chassis gt Specifies the location of the redundant power supply or cooling unit in the chassis for example Redundancy unit Fan Enclosure SD card device type lt Type of SD card device gt Specifies the type of SD card device for example SD card devic Hypervisor typ Traps 697 Table 26 1 Trap Description Reference continued Description Line Item Explanation SD card state lt State of SD card gt Specifies the state of the SD card for example SD card state Present Failed Sensor location lt Location in chassis gt Specifies the location of the sensor in the specified chassis for example Sensor location CPU1 Temperature sensor value in degrees Celsius lt Reading gt Specifies the temperature in degrees Celsius for example Temperature sensor value in degrees Celsius 30 Voltage sensor value in Volts lt Reading gt Specifies the voltage sensor value in volts for example Voltage sensor value 1 693 Understanding Trap Severity Traps often contain information ab
283. eAccess Type See Table 19 1 Access Read only Remote Access State Capabilities Name remoteAccessStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 4 Description Defines the state capabilities of the remote access hardware Syntax DellStateCapabilities Access Read only 462 Remote Access Group Remote Access State Settings Name remoteAccessStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 5 Description Defines the state setting of the remote access hardware Syntax DellStateSettings Access Read write Remote Access Status Name remoteAccessStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 6 Description Defines the status of the remote access hardware Syntax DellStatus Access Read only Remote Access Product Info Name Name remoteAccessProduct InfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 7 Description Defines the name of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 63 Access Read only Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 8 Description Defines the description of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 255 Access Read only Remote Access Group _ 463 Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 9 Description Defines the versi
284. ead write Device Group 299 PCI Device Configuration Space Status Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceStatus 1 3 6 1 4 1 674 10892 1 1100 82 1 5 Defines the status of the PCI device configuration DellStatus Read only PCI Device Index Reference Name Object ID Description Syntax Access pCIDeviceIndexReferenc 1 3 6 1 4 1 674 10892 1 1100 82 1 6 Defines the index number of PCI device that this configuration applies to DellObjectRange Read only PCI Device Configuration Space Bus Number Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceBusNumber 1 3 6 1 4 1 674 10892 1 1100 82 1 7 Defines the bus number of the PCI device configuration in this chassis DellUnsigned32BitRange Read only PCI Device Configuration Space Device Number Name Object ID Description Syntax Access 300 pCIDeviceConfigurationSpaceDeviceNumber 1 3 6 1 4 1 674 10892 1 1100 82 1 8 Defines the device number of the PCI device in this chassis DellUnsigned32BitRange Read only Device Group PCI Device Configuration Space Function Number Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceFunctionNumber 1 3 6 1 4 1 674 10892 1 1100 82 1 9 Defines the function number of the PCI device in this chassis DellUnsigned32BitRange Read only PCI Device Configuration Space Header Name Object ID Description Syntax Acces
285. ect memory access 8 Power Group defines variables for power units power 600 supplies and their current and voltage probes 9 Thermal Group defines variables for temperature probes and 700 cooling devices 10 User Security Group defines variables for creating and 800 modifying user accounts 11 Remote Flash BIOS Group defines variables for updating the 900 system s BIOS remotely 12 Port Group defines variables for major port types such as 1000 keyboard monitor small computer system interface SCSI Universal Serial Bus USB and parallel and serial ports 24 Introduction Table 1 2 Server Administrator Instrumentation MIB Sections in This Guide continued Section Topics MIB Group Numbers 13 Device Group defines variables for pointing 1100 keyboard processor cache memory and personal computer interface devices 14 Slot Group defines variables for the system s slots 1200 15 Memory Group defines variables for the system s 1300 physical memory 16 BIOS Setup Control Group defines variables for BIOS 1400 functions such as boot sequence speakers Wake on the local area network LAN diskettes ports and network interface controllers NIC 17 Local Response Agent Group defines variables for global 1500 settings and actions These variables allow users to predetermine how the system responds to a particular type of event 18 Cost of Ownership Group d
286. edundancy sensor in the specified system detected that a lost redundancy device has been reconnected Redundancy unit lt Redundancy location in ee or replaced full redundancy Chassis location is in effect The redundancy lt Name of chassis gt unit location chassis Previous redundancy location and previous state was lt State gt redundancy state are Number of devices provided required for full redundancy lt Number gt Traps 711 Table 26 8 Redundancy Unit Traps continued Trap ID Description Severity Cause Redundancy Degraded 1305 Redundancy degraded Warning A redundancy sensor in the Redundancy unit lt Redundancy location in chassis gt Chassis location lt Name of chassis gt Previous redundancy state was lt State gt Number of devices required for full specified system detected that one of the components of the redundancy unit has failed but the unit is still redundant The redundancy unit location chassis location and previous redundancy state are provided redundancy lt Number gt Redundancy Lost 1306 Redundancy lost Warning or A redundancy sensor in the Redundancy units PE p Pee fies detected lt Redundancy location in depending that one of the components on the in the redundant unit has chassis gt i l numberof been disconnected has Chassis location units that failed or is not present The SME OE Chae ee are redundancy unit location Previous redunda
287. efines the index of the memory device s associated with this memory device mapped address DellObjectRange Read only Memory Device Mapped Address Row Position Name Object ID Description Syntax Access memoryDeviceMappedAddressRowPosition 1 3 6 1 4 1 674 10892 1 1100 60 1 7 Defines the position of the referenced memory in a row of the memory device mapped address DellUnsigned32BitRange Read only Memory Device Mapped Address Interleave Position Name Object ID Description Syntax Access memoryDeviceMappedAddressInterleavePosition 1 3 6 1 4 1 674 10892 1 1100 60 1 8 Defines the position of the referenced memory in an interleave of the memory device mapped address DellUnsigned32BitRange Read only Device Group 291 Memory Device Mapped Address Interleave Depth Name Object ID Description Syntax Access memoryDeviceMappedAddressInterleaveDepth 1 3 6 1 4 1 674 10892 1 1100 60 1 9 Defines the maximum number of consecutive rows from the referenced memory device that are accessed in a single interleaved transfer in the memory device mapped address DellUnsigned32BitRange Read only Memory Device Mapped Address Starting Address Name Object ID Description Syntax Access memoryDeviceMappedAddressStartingAddress 1 3 6 1 4 1 674 10892 1 1100 60 1 10 Defines the physical starting address in KB of the memory device mapped address DellUnsigned64BitRan
288. efines the redundancy status of the SD Card unit Syntax DellStatusRedundancy Access Read only SD Card Unit Count For Redundancy Name sdCardUnitCountForRedundancy Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 6 Description Defines the total number of SD Card devices required for this SD Card unit to have full redundancy Syntax DellObjectRange Access Read only SD Card Unit Name Name sdCardUnitName Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 7 Description Defines the name of the SD Card unit Syntax DellString Access Read only Device Group 313 SD Card Unit Status Name sdCardUnitStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 8 Description Defines the status of the SD Card unit Syntax DellStatus Access Read only SD Card Device Table Name sdCardDeviceTable Object ID 1 3 6 1 4 1 674 10892 1 1100 112 Description Defines the SD Card Device Table Syntax SEQUENCE OF SdCardDeviceTableEntry Access Not accessible SD Card Device Table Entry Name sdCardDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 112 1 Description Defines the SD Card Device Table Entry Syntax SdCardDeviceTableEntry Access Not accessible Index sdCardDeviceChassisIndex sdCardDeviceIndex SD Card Device Chassis Index Name Object ID Description Syntax 314 sdCardDeviceChassisIndex 1 3 6 1 4 1 674 10892 1 1100 112 1 1 Defines the index one based of the chassis that contains the SD Card device DellObject
289. efines variables for tracking data 1600 on the system s service contract lease repair records trouble tickets and so on 20 Cluster Group defines variables for systems that operate asa 1800 cluster 21 Baseboard Management Controller Group provides 1900 information about the Baseboard Management Controller BMC that may be present in your system In addition to providing general information about the BMC this group provides information about the serial and local area network LAN interfaces of the BMC 26 Traps defines the types of alerts that can be sent to report the 5000 status of critical components Server Administrator Remote Access MIB The Server Administrator Remote Access MIB filename dces3rmt mib provides in band information about remote access hardware that may be present in your system Introduction 25 The Server Administrator Remote Access MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information Table 1 3 describes each Server Administrator Remote Access MIB group and lists the MIB group number assigned to the MIB group The Server Administrator Remote Access MIB groups are identified by the SNMP OID 1 3 6 1 4 1 674 10892 1 lt MIB group number gt where lt MIB group number gt is the MIB group number assigned to the MIB group See the relevant section for more information about the MIB objects defined in a MIB group Table 1 3 Serve
290. ellString Access Read only Systems Management Software Feature Flags Name systemManagement SoftwareFeatureFlags Object ID 1 3 6 1 4 1 674 10892 1 100 11 Description Defines the features of the systems management software Syntax SMSFeatureFlags See Table 3 2 Access Read only 48 Systems Management Software Group Systems Management Software SNMP Agent Feature Flags Name systemManagementSoftwareSNMPAgentFeatureFlags Object ID 1 3 6 1 4 1 674 10892 1 100 12 Description Defines the features of the SNMP agent software provided by the operating system Syntax SMSSNMPAgentFeatureF lags See Table 3 3 Access Read only Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1 3 6 1 4 1 674 10892 1 100 13 Description Defines the manufacturer of the systems management software Syntax DellString Access Read only Systems Management Software Variable Values This section includes definitions of server administrator specific variable values used in this section Table 3 1 Systems Management Software Supported Standards Variable Name SMSSupportedTypes Data Type Integer Possible Data Values Meaning of Data Value supportsSNMP 1 This system supports SNMP supportsDMI 2 This system supports DMI supportsSNMPandDMI 3 This system supports SNMP and DMI support sCIMOM 4 This system supports CIM supportsSNMPandCIMOM 5 This system supports SNMP and
291. ely identifies the object causing the alert and can be used to correlate different alerts caused by the same object OBJECT IDENTIFIER alertMessage 1 3 6 1 4 1 674 10892 1 5000 10 3 Describes the alert DisplayString SIZE 0 1024 Current Status Variable Name Object ID Description Syntax Previous Status Variable Name Object ID Description Syntax Data Variable Name Object ID Description Syntax alertCurrentStatus 1 3 6 1 4 1 674 10892 1 5000 10 4 Gives the current status of the object causing the alert DellStatus alertPreviousStatus 1 3 6 1 4 1 674 10892 1 5000 10 5 Gives the previous status of the object causing the alert DellStatus alertData 1 3 6 1 4 1 674 10892 1 5000 10 6 Provides Server Administrator defined data related to the alert OCTET STRING SIZE 0 1024 Traps 693 694 Understanding the Trap Description Table 26 1 lists in alphabetical order each line item that may appear in the trap description Table 26 1 Trap Description Reference Description Line Item Explanation Action performed was lt Action gt Specifies the automatic server recovery action that was performed for example Action performed was Power cycle Action requested was lt Action gt Specifies the user initiated host control action that was requested for example Action requested was Reboot shutdown OS first Additional details lt Additiona
292. em slot that this PCI device is in DellObjectRange Read only PCI Device Data Bus Width Name Object ID Description Syntax Access pCIDeviceDataBusWidth 1 3 6 1 4 1 674 10892 1 1100 80 1 7 Defines the bus width of the PCI device in this chassis DellUnsigned32BitRange Read only PCI Device Manufacturer Name Name Object ID Description Syntax Access pCIDeviceManufacturerName 1 3 6 1 4 1 674 10892 1 1100 80 1 8 Defines the name of the PCI device manufacturer DellString Read only PCI Device Description Name Name Object ID Description Syntax Access pCIDeviceDescriptionName 1 3 6 1 4 1 674 10892 1 1100 80 1 9 Defines the descriptive name of the PCI device DellString Read only Device Groups 297 PCI Device Speed Name pCIDeviceSpeed Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 10 Description Defines the bus speed in MHz of the PCI device in this chassis A zero 0 indicates that the speed is unknown Syntax DellUnsigned32BitRange Access Read only PCI Device Adapter Fault Name pCIDeviceAdapterFault Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 11 Description Defines whether the PCI device in this chassis has detected a fault Syntax DellBoolean Access Read only PCI Device Configuration Space Table Name pCIDeviceConfigurationSpaceTable Object ID 1 3 6 1 4 1 674 10892 1 1100 82 Description Defines the PCI Device Configuration Table Syntax SEQUENCE OF PC IDeviceConfigurationSp
293. emSlotSlotID Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 10 Description Defines the slot identification number of the system slot A zero 0 indicates that the slot is embedded on the motherboard Syntax DellUnsigned32BitRange Access Read only System Slot Category Name systemSlotCategory Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 11 Description Defines the system slot category Syntax DellUnsigned32BitRange Access Read only System Slot Hot Plug Bus Width Name Object ID Description Syntax Access 348 systemSlotHotPlugBusWidth 1 3 6 1 4 1 674 10892 1 1200 10 1 12 Defines the bus width of the hot plug system slot DellSystemSlotHotPlugBusWidth See Table 14 7 Read only Slot Group System Slot Hot Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 13 Description Defines the slot speed in megahertz of the hot plug system slot A zero 0 indicates that the slot speed is unknown Syntax DellUnsigned32BitRange Access Read only System Slot Hot Plug Adapter Speed Name systemSlotHotPlugAdapterSpeed Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 14 Description Defines the adapter speed in megahertz of the hot plug system slot A zero 0 indicates that the slot speed is unknown Syntax DellUnsigned32BitRange Access Read only System Slot Variable Values This section includes definitions for server administrator specific variable values used in this section Tab
294. emSlotUsagelIsInuUse 4 The system slot is in use Table 14 5 System Slot Length Variable Name Del 1SystemSlotLength Data Type Integer Possible Data Values Meaning of Data Value systemSlotLengthIsOther 1 The system slot length is not one of following systemSlotLengthIsUnknown 2 The system slot length is unknown systemSlotLengthIsShort 3 The system slot length is short systemSlotLengthIsLong 4 The system slot length is long Slot Group 355 Table 14 6 System Slot Category Variable Name De11SystemSlotCategory Data Type Integer Possible Data Values ng of Data Value systemSlotCategorylIsOther 1 systemSlotCategorylIsUnknown 2 systemSlotCategorylIsBusConnector 3 systemSlotCategoryIsPCMCIA 4 systemSlotCategorylIsMotherboard 5 The system slot category is not one of following The system slot category is unknown The system slot is a bus connector The system slot category is PCMCIA The system slot is a motherboard Table 14 7 Hot Plug Bus Width Variable Name De11SystemSlotHotPlugBusWidth Data Type Integer Possible Data Values Meaning of Data Value busWidthIsOther 1 The system slot bus width is not one of following busWidthIsUnknown 2 The system slot bus wid th is unknown busWidthIs8bits 3 The system slot bus wid th is 8 bits bus
295. eon processor 5000 Series deviceFamilyIsDualCoreIntelxeo The processor family is Dual Core Intel nLV 166 Xeon processor LV deviceFamilyIsDualCoreIntelxeo The processor family is Dual Core Intel nULV 167 Xeon processor ULV deviceFamilyIsDualCoreIntelxeo The processor family is Dual Core Intel n7100 168 Xeon processor 7100 Series deviceFamilyIsQuadCoreIntelxeo The processor family is Quad Core Intel n5400 169 Xeon processor 5400 Series deviceFamilyIsQuadCoreIntelxeo The processor family is Quad Core Intel n 170 Xeon deviceFamilyIsDualCoreIntelxeo The processor family is Dual Core Intel n5200 171 Xeon processor 5200 Series deviceFamilyIsDualCoreIntelxeo The processor family is Dual Core Intel n7200 172 Xeon processor 7200 Series deviceFamilyIsQuadCoreIntelxeo The processor family is Quad Core Intel n7300 173 Xeon processor 7300 Series deviceFamilyIsQuadCoreIntelxeo The processor family is Quad Core Intel n7400 174 Xeon processor 7400 Series deviceFamilyIsMultiCoreIntelXxe The processor family is Multi Core Intel on7400 175 Xeon processor 7400 Series deviceFamilyIsM1 176 The processor family is M1 deviceFamilyIsM2 177 The processor family is M2 deviceFamilyIsIntelPentium4HT The processor family is Intel Pentium 4 179 HT processor deviceFamilyIsAS400 180 The processor family is AS400 Device Group 327 Table 13 6 Processor Device Family continued Variable Name De 1
296. er Memory Card International Association PCMCIA standards systemSlotIsVLVESA 8 The system slot is Very Low Voltage Enterprise System Architecture VLVESA systemSlotIsProprietary 9 The system slot is proprietary systemSlotIsProcessorCard 10 The system slot is a processor card systemSlotIsProprietaryMemory 11 The system slot is proprietary memory systemSlotIsIORiserCard 12 The system slot is an I O riser card systemSlotIsNuBUS 13 The system slot is a NuBus systemSlotIsPCI66MHz 14 The system slot is a PCI66MHz systemSlotIsAGP 15 The system slot is an Advanced Graphics Port AGP systemSlotIsAGP2X 16 The system slot is an AGP 2x card systemSlotIsAGP4xX 17 The system slot is an AGP 4x card Slot Group 353 Table 14 3 System Slot Type continued Variable Name De11SystemSlotType Data Type Integer Possible Data Values Meaning of Data Value systemSlotIsPC98C20 18 The system slot is a PC 98 C20 systemSlotIsPC98C24 19 The system slot is a PC 98 C24 systemSlotIsPC98E 20 The system slot type is PC 98 E systemSlotIsPC98LocalBus 21 The system slot type is a PC 98 local bus systemSlotIsPC98Card 22 The system slot type is a PC 98 card systemSlotIsPCIX 23 The system slot type is a PCIX card systemSlotIsPCIExpress 24 The system slot type is a PCI Express card systemSlotIsAGP8x 25 The system slot type is an AGP 8x ca
297. erating system image used by the remote access hardware Syntax IpAddress Access Read write Remote Access Floppy TFTP Path Name Name remoteAccessFloppyTFTPPathName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 22 Description Defines the file name of the operating system image obtained from the TFTP server used by the remote access hardware Syntax DisplayString SIZE 0 255 Access Read write Remote Access Group _ 473 Remote Access Firmware Update IP Address Name remoteAccessFirmwareUpdateIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 23 Description Defines the IP address of the update server providing the firmware image used by the remote access hardware Syntax IpAddress Access Read write Remote Access Firmware Update Path Name Name remoteAccessFirmwareUpdatePathName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 24 Description Defines the file name of the firmware image obtained from the update server used by the remote access hardware Syntax DisplayString SIZE 0 255 Access Read write Remote Access Network Interface Controller NIC Static IP Address Name remoteAccessNICStaticIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 25 Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read write Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1 3 6 1 4 1 67
298. eredOn 4 The system slot power and corresponding LED is on systemSlotHotPlugIsAtAttention 8 The system slot attention state and corresponding LED is on systemSlotHotPlugHasPowerFaulted Power on fault and corresponding 16 LED was detected due to a short or overcurrent systemSlotHotPlugAdapterIsPresent Adapter card present in slot 32 may not be powered systemSlotHotPlugAdapterPresentAnd Adapter card present in slot PoweredOn 36 and powered systemSlotHotPlugPowerButtonPressed The system slot power button 64 pressed to signal a toggle of the power state systemSlotProvides5Volts 128 The system slot provides a 5 V supply systemSlotProvides3Point3Volts 256 The system slot provides a 3 3 V supply systemSlotIsShared 512 The slot s opening is shared with another slot Slot Group 351 Table 14 2 System Slot State Settings continued Variable Name Del 1SystemSlotStateSettings Data Type Integer Possible Data Values Meaning of Data Value systemSlotSupportsCard16 1024 The system slot supports PC Card 16 systemSlot Support sCardBus 2048 The system slot supports CardBus systemSlotSupportsZoomVideo 4096 The system slot supports zoom video systemSlotSupportsModemRingResume The system slot supports modem 8192 ring resume systemSlotSupport sPMESignal 16384 The system slot supports power management enable PME signa
299. erenc Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 6 Description Defines the index to the associated system resource owner in this chassis Syntax DellObjectRange Access Read only System Resource 1 0 Port Share Disposition Name systemResourcelOPortShareDisposition Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 7 Description Defines the share disposition of the system resource I O port Syntax DellResourceShareDisposition See Table 7 3 Access Read only System Resource 1 0 Port Starting Address Name systemResourcelOPortStartingAddress Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 8 Description Defines the 64 bits of the starting address of the system resource T O port Syntax DellUnsigned64BitRange Access Read only 134 System Resource Group System Resource 1 0 Port Ending Address Name Object ID Description Syntax Access systemResourcelOPortEndingAddress 1 3 6 1 4 1 674 10892 1 500 30 1 9 Defines the 64 bits of the ending address of the system resource I O port DellUnsigned64BitRange Read only System Resource Memory Table Name Object ID Description Syntax Access systemResourceMemoryTable 1 3 6 1 4 1 674 10892 1 500 40 Defines the System Resource Memory Table SEQUENCE OF SystemResourceMemoryTableEntry Not accessible System Resource Memory Table Entry Name Object ID Description Syntax Access Index systemResourceMemoryTableEntry 1 3 6 1 4 1 674 10892 1 500 40 1 Defi
300. erface Alert Community Name Name bmcLANInterfaceAlertCommunit yName Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 13 Description Defines the SNMP community used for BMC LAN alerts traps sent on the BMC LAN interface Syntax DisplayString SIZE 0 32 Access Read only 532 Baseboard Management Controller Group Baseboard Management Controller Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 21 1 BMC Serial Connection Mode Capabilities Variable Name De 1 1BMCSerialConnectionModeCapabilities Data Type Integer These values are bit masks therefore combination values are possible Possible Data Values Meaning of Data Value none 0 No mode capabilities modemBasic 1 BMC serial interface supports Modem Basic mode modemPPP 2 BMC serial interface supports Modem Point to Point Protocol PPP mode modemTerminal 4 BMC serial interface supports Modem Terminal mode directBasic 8 BMC serial interface supports Direct Basic mode directPPP 16 BMC serial interface supports Direct PPP mode directTerminal 32 BMC serial interface supports Direct Terminal mode Table 21 2 BMC Serial Connection Mode Settings Variable Name De 1 1BMCSerialConnectionModeSettings Data Type Integer These values are bit masks therefore combination values are possible Possible Dat
301. erical order and includes each trap ID s corresponding description severity level and cause Description text in brackets for example lt State gt describes the event specific information provided by Server Administrator RAC Traps lists RAC trap IDs in numerical order and includes each trap ID s corresponding description severity level and cause BMC Traps lists BMC trap IDs and includes each trap ID s corresponding description and severity level Traps 691 692 Trap Variables This section describes the variables that are sent to the management console to provide additional information about a trap or alert generated by some event on your system The trap variables presented here apply to all Instrumentation and RAC traps Trap variables are sent in the order listed and are reserved for use only in traps When a varbind is created for a trap variable a zero is appended to the object ID OID to create the OID for the varbind System Variable Name Object ID Description Syntax Table Index OID Variable Name Object ID Description Syntax Message Variable Name Object ID Description Syntax Traps alertSystem 1 3 6 1 4 1 674 10892 1 5000 10 1 Identifies the system generating the alert DisplayString SIZE 0 255 alertTableIndexOID 1 3 6 1 4 1 674 10892 1 5000 10 2 Gives the object identifier for the index attribute in the table that contains the object causing the alert Uniqu
302. es The following management information base MIB tables define the objects in the Memory Group e Physical Memory Array Table e Physical Memory Array Mapped Table e Physical Memory Configuration Table e Physical Memory Logging Table e Redundant Memory Unit Table e Physical Memory Card Table Physical Memory Array Table The physical memory array is the entire physical memory of a system The example that follows shows variable values for a system that has one 128 megabyte MB dual in line memory module DIMM e physicalMemoryArrayMaximumSize 2 097 152 kilobytes KB or 2 gigabytes GB e physicalMemoryArrayTotalNumberSockets 4 the example system has four DIMM slots on the motherboard e physicalMemoryArrayInUseNumberSockets there is only one DIMM installed Memory Group 359 The following object sets up the Physical Memory Array Table Name Object ID Description Syntax Access physicalMemoryArrayTable 1 3 6 1 4 1 674 10892 1 1300 10 Defines the Physical Memory Array Table PhysicalMemoryArrayTableEntry Not accessible Physical Memory Array Table Entry Name Object ID Description Syntax Access Index physicalMemoryArrayTableEntry 1 3 6 1 4 1 674 10892 1 1300 10 1 Defines the Physical Memory Array Table entry PhysicalMemoryArrayTableEntry Not accessible physicalMemoryArraychassisIndex physicalMemoryArrayIndex Physical Memory Array Chassis Index Name Object ID De
303. es Meaning of Data Value if set to zero 0 The object has no settings capabilities and its state is disabled unknown 1 The object s state is unknown enabled 2 The object s state is disabled offline a binary 0 value or enabled online a binary l value not Ready 4 The object is not ready enableAndNot Ready 6 The object is enabled and not ready Table A 4 Dell Probe Capabilities Variable Name De11ProbeCapabilities Data Type Integer Possible Data Values Meaning of Data Value if set to zero 0 The object has no capabilities upperNonCriticalThresholdSet The upper noncritical threshold Capable 1 can be set lowerNonCriticalThresholdSet The lower noncritical threshold Capable 2 can be set upperNonCriticalThresholdDef The upper noncritical threshold aultCapable 4 can be set to default lowerNonCriticalThresholdDef The lower noncritical threshold aultCapable 8 can be set to default Standard Data Type Definitions 745 Dell Status Data Types Status data types include DellStatus DellStatusRedundancy and DellStatusProbe Table A 5 Dell Status Variable Name De11Status Data Type Integer Possible Data Values Meaning of Data Value other 1 The object s status is not one of the following unknown 2 The object s status is unknown ok 3 The object s status is OK nonCritical 4 The object s status
304. es the Keyboard Port Table entry KeyboardPortTableEntry Not accessible keyboardPortchassisIndex keyboardPortIndex Port Group Keyboard Port Chassis Index Name Object ID Description Syntax Access keyboardPortchassisIndex 1 3 6 1 4 1 674 10892 1 1000 20 1 1 Defines the index one based of this chassis DellObjectRange Read only Keyboard Port Index Name Object ID Description Syntax Access keyboardPort Index 1 3 6 1 4 1 674 10892 1 1000 20 1 2 Defines the index of the keyboard ports in this chassis DellObjectRange Read only Keyboard Port State Capabilities Name Object ID Description Syntax Access keyboardPortStateCapabilities 1 3 6 1 4 1 674 10892 1 1000 20 1 3 Defines the capabilities of the keyboard port DellStateCapabilities Read only Keyboard Port State Settings Name Object ID Description Syntax Access keyboardPortStateSettings 1 3 6 1 4 1 674 10892 1 1000 20 1 4 Defines the state and settings of the keyboard port DellStateSettings Read only PortGroup 229 Keyboard Port Status Name keyboardPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 20 1 5 Description Defines the status of the keyboard port Syntax DellStatus Access Read only Keyboard Port Security State Name keyboardPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 20 1 6 Description Defines the security settings of the keyboard port Syntax DellPortSecurityState Access Read only
305. es the bitmap of supported methods for firmware update DellUnsigned16BitRange Read only Firmware Date Name Name Object ID Description Syntax Access firmwareDateName 1 3 6 1 4 1 674 10892 1 300 60 1 10 Defines the date of the firmware DellDateName Read only Chassis Information Group 99 Firmware Version Name Name Object ID Description Syntax Access firmwareVersionName 1 3 6 1 4 1 674 10892 1 300 60 1 11 Defines the version name of the firmware DellString Read only Intrusion Table The following objects and attributes describe the different forms of chassis intrusion a situation that occurs when the cover of a computer is removed Name Object ID Description Syntax Access intrusionTable 1 3 6 1 4 1 674 10892 1 300 70 Defines the Intrusion Table SEQUENCE OF IntrusionTableEntry Not accessible Intrusion Table Entry Name Object ID Description Syntax Access Index intrusionTableEntry 1 3 6 1 4 1 674 10892 1 300 70 1 Defines the Intrusion Table entry Intrusion TableEntry Not accessible intrusionchassisIndex intrusionIndex Intrusion Chassis Index Name Object ID Description Syntax Access intrusionchassisIndex 1 3 6 1 4 1 674 10892 1 300 70 1 1 Defines the index one based of this chassis DellObjectRange Read only 100 Chassis Information Group Intrusion Index Name Object ID Description Syntax Access intrusionIndex 1 3 6 1 4 1 674 10892 1
306. estinations modem configuration for dial up networking dial in configuration and dial out destinations DRAC 4 and DRAC 5 On systems with Dell Remote Access Controller DRAC 4 or DRAC 5 the Remote Access Group includes only the Remote Access Table Remote Access Table The following MIB object sets up the Remote Access Table Name remoteAccessTabl Object ID 1 3 6 1 4 1 674 10892 1 1700 10 Description Defines the Remote Access Table Syntax SEQUENCE OF RemoteAccessTableEntry Access Not accessible Remote Access Table Entry Name remoteAccessTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 Description Defines the Remote Access Table entry Syntax RemoteAccessTableEntry Access Not accessible Index remoteAccessChassisIndex remoteAccessAdapterIndex Remote Access Group 461 Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellObjectRange Access Read only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 2 Description Defines the index one based of the remote access hardware Syntax DellObjectRange Access Read only Remote Access Type Name remoteAccessTyp Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 3 Description Defines the type of remote access hardware Syntax DellRemot
307. ettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no monitor settings unknown 1 The remote access hardware monitor settings are unknown extPwrSupplyMonitorIfConn The remote access hardware will monitor the ectedEnabled 2 external power supply if connected extPwrSupplyMonitorAlways The remote access hardware will always EnabledEnabled 4 monitor the external power supply Table 19 6 Remote Access Local Area Network LAN Capabilities Variable Name De 1 1RemoteAccessLANCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no LAN capabilities unknownCapabilities 1 The remote access hardware LAN capabilities are unknown nicCapable 2 The remote access hardware has a network interface controller NIC nicDHCPCapable 4 The remote access hardware NIC can use DHCP to obtain an IP address Remote Access Group 503 Table 19 7 Remote Access LAN Settings Variable Name De 1 1RemoteAccessLANSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no LAN settings unknown 1 The remote access hardware LAN settings are unknown nicEnabled 2 The remote access hardware NIC is enabled nicDHCPEnabled 4 The remote access hardware NI
308. evice State Settings Name Object ID Description Syntax Access memoryDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 50 1 4 Defines the state of the memory device DellStateSettings Read write Memory Device Status Name Object ID Description Syntax Access 282 memoryDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 50 1 5 Defines the status of the memory device DellStatus Read only Device Group Memory Device Memory Port Index Reference Name Object ID Description Syntax Access memoryDeviceMemoryPort IndexReference 1 3 6 1 4 1 674 10892 1 1100 50 1 6 Defines the index of the memory port of which this memory device is part DellObjectRange Read only Memory Device Type Name Object ID Description Syntax Access memoryDeviceTyp 1 3 6 1 4 1 674 10892 1 1100 50 1 7 Defines the type of the memory device DellMemoryDeviceType See Table 13 16 Read only Memory Device Location Name Name Object ID Description Syntax Access memoryDeviceLocationName 1 3 6 1 4 1 674 10892 1 1100 50 1 8 Defines the location name of the memory device DellString Read write Device Group 283 Memory Device Error Count K NOTE Memory Device Failure Modes has now replaced this attribute Memory Syntax Access Name Object ID Description Device Error Count should no longer be used If you use the Memory Device Error Count attribute the value returned is always zero and u
309. evices in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific intrusion detection device The first byte returned represents the status of the first intrusion detection device the second byte returned represents the status of the second intrusion detection device and so on The bytes have the same definition type as DellStateSettings OCTET STRING SIZE 1 128 Read only System State Chassis Intrusion Status Combined Name Object ID Description Syntax Access systemStateChassisIntrusionStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 30 Defines the intrusion status of all intrusion detection devices in this chassis The result is returned as a combined status value The value has the same definition type as DellStatus DellStatus Read only System State Chassis Intrusion Status Details Name Object ID Description Syntax Access systemStateChassisIntrusionStatusDetails 1 3 6 1 4 1 674 10892 1 200 10 1 31 Defines the intrusion status of all intrusion detection devices in this chassis The first byte returned represents the status of the first intrusion detection device the second byte returned represents the status of the second intrusion detection device and so on OCTET STRING SIZE 1 128 Read only System State Group 61 System State AC Power Switch State Details Name systemStateACPowerSwitchStateDetails Object I
310. f operating system shutdown Table 26 2 Miscellaneous Traps continued Trap Description ID Severity Cause System Peak Power New Peak 1013 System Peak Power detected new peak value Peak value in Watts lt Reading gt Information This message is generated when the system peak power sensor has detected a new peak value System Software Event 1014 System software event has occured Description lt Description of event gt Date and time of action lt Date and time gt Minor This message is generated when a system software event occurs The description of the event and the date and time of the event are provided Temperature Probe Traps Temperature probes help protect critical components by alerting the systems management console when temperatures become too high inside a chassis The temperature probe traps use additional variables sensor location chassis location previous state and temperature sensor value reported in degrees Celsius Traps 701 Table 26 3 Temperature Probe Traps 702 Trap ID Description Severity Cause Temperature Probe Normal 1052 Temperature sensor returned Information A temperature sensor to a normal value on the backplane Sensor location board system board zio cation Sn chassiss or drive carrier in the i specified system Chassis location returned to a valid SNam Of chassis range after crossing a Previous state w
311. f the event for this system DellUnsigned32BitRange Read write COO Cost Event Log Duration Type Name Object ID Description Syntax Access cooCostEventLogDurationType 1 3 6 1 4 1 674 10892 1 1600 30 1 5 Defines the duration type of the event for this system DellCOOHourDayDurationType See Table 18 2 Read write COO Cost Event Log Description Name Name Object ID Description Syntax Access cooCostEventLogDescriptionName 1 3 6 1 4 1 674 10892 1 1600 30 1 6 Defines the name of the event description DellCostofOwnershipString Read write Cost of Ownership Group 441 COO Warranty Table The COO Warranty Table objects enable you to track facts about the type and duration of the warranty for a particular system Name cooWarrantyTable Object ID 1 3 6 1 4 1 674 10892 1 1600 40 Description Defines the COO Warranty Table Syntax SEQUENCE OF CooWarranty TableEntry Access Not accessible COO Warranty Table Entry Name cooWarrantyTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 Description Defines the COO Warranty Table entry Syntax CooWarranty TableEntry Access Not accessible Index cooWarrantychassisIndex cooWarrantyIndex COO Warranty Chassis Index Name cooWarrantychassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read write COO Warranty Index Name cooWarrantyIndex Object ID 1 3 6 1 4
312. f the power unit in this chassis Syntax DellObjectRange Access Read only Power Unit State Capabilities Name powerUnitStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 3 Description Defines the capabilities of the power unit Syntax DellStateCapabilities Access Read only 150 Power Group Power Unit State Settings Name Object ID Description Syntax Access powerUnitStateSettings 1 3 6 1 4 1 674 10892 1 600 10 1 4 Defines the state and settings of the power unit DellStateSettings Read write Power Unit Redundancy Status Name Object ID Description Syntax Access powerUnitRedundancyStatus 1 3 6 1 4 1 674 10892 1 600 10 1 5 Defines the redundancy status of the power unit DellStatusRedundancy Read only Power Supply Count for Redundancy Name Object ID Description Syntax Access Power Unit Name Name Object ID Description Syntax Access powerSupplyCountForRedundancy 1 3 6 1 4 1 674 10892 1 600 10 1 6 Defines the total number of power supplies required for this power unit to have redundancy DellString Read only powerUnitName 1 3 6 1 4 1 674 10892 1 600 10 1 7 Defines the name of the power unit in this chassis DellString Read only Power Group 151 Power Unit Status Name powerUnitStatus Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 8 Description Defines the status of the power unit in this chassis Syntax DellStatus Access Read only Power Supply Table
313. fines the speed of the cache device in nanoseconds A zero 0 indicates that the speed is unknown Syntax DellUnsigned32BitRange Access Read only Cache Device Write Policy Name cacheDeviceWritePolicy Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 15 Description Defines the write policy of the cache device Syntax DellCacheDeviceWnitePolicy See Table 13 9 Access Read only Device Group 279 Cache Device Is Socketed Name Object ID Description Syntax Access cacheDevicelIsSocketed 1 3 6 1 4 1 674 10892 1 1100 40 1 16 Defines if the cache device is socketed DellBoolean Read only Cache Device Error Checking and Correction ECC Type Name Object ID Description Syntax Access cacheDeviceECCTyp 1 3 6 1 4 1 674 10892 1 1100 40 1 17 Defines the type of error correction in use by the cache device DellCacheDeviceECCType See Table 13 11 Read only Cache Device Associativity Name Object ID Description Syntax Access cacheDeviceAssociativity 1 3 6 1 4 1 674 10892 1 1100 40 1 18 Defines the type of associativity in use by the cache device DellCacheDeviceAssociativity See Table 13 12 Read only Cache Device Supported Type Name Object ID Description Syntax Access 280 cacheDeviceSupportedType 1 3 6 1 4 1 674 10892 1 1100 40 1 19 Defines the type of static random access memory SRAM that the cache device can support DellCacheDeviceSupportedType Read only Devi
314. following objects describe the fields for server administrator systems management information The systems management software variables are scalar objects meaning that they are not related to other management information base MIB objects and are thus not placed in a table Systems Management Software Name Name systemManagementSoftwareName Object ID 1 3 6 1 4 1 674 10892 1 100 1 Description Defines the systems management software product name Syntax DellString Access Read only Systems Management Software Version Number Name Name systemManagementSoftwareVersionNumberName Object ID 1 3 6 1 4 1 674 10892 1 100 2 Description Defines the version number of the systems management software Syntax DellString Access Read only Systems Management Software Build Number Name systemManagementSoftwareBuildNumber Object ID 1 3 6 1 4 1 674 10892 1 100 3 Description Defines the build number of the systems management software Syntax DellUnsigned16BitRange Access Read only 46 Systems Management Software Group Systems Management Software Description Name Name systemManagementSoftwareDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 100 4 Description Defines the description of the systems management software Syntax DellString Access Read only Systems Management Software Supported Protocol Name systemManagementSoftwareSupportedProtocol Object ID 1 3 6 1 4 1 674 10892 1 100 5 Description Defines the systems management stand
315. for the memory device DellString Read only Memory Device Serial Number Name Name Object ID Description Syntax Access memoryDeviceSerialNumberName 1 3 6 1 4 1 674 10892 1 1100 50 1 23 Defines the serial number of the memory device DellString Read only Memory Device Asset Tag Name Name Object ID Description Syntax Access memoryDeviceAssetTagName 1 3 6 1 4 1 674 10892 1 1100 50 1 24 Defines the asset tag of the memory device DellString Read only Memory Device Speed Name Name Object ID Description Syntax Access 288 memoryDeviceSpeedNam 1 3 6 1 4 1 674 10892 1 1100 50 1 25 This attribute defines the speed of the memory device in string format with units specified in string DellString Read only Device Group Memory Device Mapped Address Table Name Object ID Description Syntax Access memoryDeviceMappedAddressTabl 1 3 6 1 4 1 674 10892 1 1100 60 Defines the Memory Device Mapped Address Table SEQUENCE OF MemoryDeviceMappedAddressTableEntry Not accessible Memory Device Mapped Address Table Entry Name Object ID Description Syntax Access Index memoryDeviceMappedAddressTableEntry 1 3 6 1 4 1 674 10892 1 1100 60 1 Defines the Memory Device Mapped Address Table entry MemoryDeviceMappedAddressTableEntry Not accessible memoryDeviceMappedAddresschassisIndex memoryDeviceMappedAddressIndex Memory Device Mapped Address Chassis Index Name
316. formance management type is Maximum Performance minPower 2 Fan power and performance management type is Minimum Power l Power Group Thermal Group The Thermal Group provides information about cooling units cooling devices and temperature probes Cooling units are sets of fans or other cooling devices in a system chassis Thermal Group variables include threshold values and types of cooling devices and temperature probes Thermal Group Tables The following management information base MIB tables define the objects in the Thermal Group Cooling Unit Table e Cooling Unit Status e Temperature Probe Table Cooling Unit Table Name coolingUnitTable Object ID 1 3 6 1 4 1 674 10892 1 700 10 Description Defines the Cooling Unit Table Syntax TableEntry Access Not accessible Cooling Unit Table Entry Name coolingUnitTableEntry Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 Description Defines the Cooling Unit Table entry Syntax TableEntry Access Not accessible Index coolingUnitchassisIndex coolingUnitIndex Thermal Group 197 Cooling Unit Chassis Index Name coolingUnitchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 1 Description Defines the index one based of this chassis Syntax TableEntry Access Read only Cooling Unit Index Name coolingUnit Index Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 2 Description Defines the index one based of cooling units Syntax DellObjectRang
317. g Port Index See Section 12 SEQUENCE OF PointingDevice TableEntry Not accessible Pointing Device Table Entry Name Object ID Description Syntax Access Index pointingDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 10 1 Defines the Pointing Device Table entry PointingDeviceTableEntry Not accessible pointing DevicechassisIndex pointingDeviceIndex Pointing Device Chassis Index Name Object ID Description Syntax Access pointingDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 10 1 1 Defines the index one based of this chassis DellObjectRange Read only Pointing Device Index Name Object ID Description Syntax Access 260 pointingDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 10 1 2 Defines the index of the pointing device in this chassis DellObjectRange Read only Device Group Pointing Device State Capabilities Name Object ID Description Syntax Access pointingDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 10 1 3 Defines the capabilities of the pointing device DellStateCapabilities Read only Pointing Device State Settings Name Object ID Description Syntax Access pointingDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 10 1 4 Defines the state of the pointing device DellStateSettings Read write Pointing Device Status Name Object ID Description Syntax Access pointingDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 10 1 5 Defines the status of the poi
318. gSystemMemoryAvailablePhysicalSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 6 Description Defines the available physical memory size in kilobytes Syntax DellUnsigned32BitRange Access Read only Operating System Memory Total Page File Size Name operatingSystemMemoryTotalPageFileSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 7 Description Defines the total page file memory size in kilobytes Syntax DellUnsigned32BitRange Access Read only Operating System Group 125 Operating System Memory Available Page File Size Name operatingSystemMemoryAvailablePageFileSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 8 Description Defines the available page file memory size in kilobytes Syntax DellUnsigned32BitRange Access Read only Operating System Memory Total Virtual Size Name operatingSystemMemoryTotalVirtualSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 9 Description Defines the total virtual memory size in kilobytes Syntax DellUnsigned32BitRange Access Read only Operating System Memory Available Virtual Size Name operatingSystemMemoryAvailableVirtualSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 10 Description Defines the available virtual memory size in kilobytes Syntax DellUnsigned32BitRange Access Read only 126 Operating System Group System Resource Group The Management Information Base MIB variables presented in this section enable you to track various attributes of your system resources This section i
319. ge Read only Memory Device Mapped Address Ending Address Name Object ID Description Syntax Access memoryDeviceMappedAddressEndingAddress 1 3 6 1 4 1 674 10892 1 1100 60 1 11 Defines the physical ending address in KB of the memory device mapped address DellUnsigned64BitRange Read only Generic Device Table Name Object ID Description Syntax Access genericDeviceTabl 1 3 6 1 4 1 674 10892 1 1100 70 Defines the Generic Device Table SEQUENCE OF GenericDeviceTableEntry Not accessible 292 Device Group Generic Device Table Entry Name Object ID Description Syntax Access Index genericDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 70 1 Defines the Generic Device Table entry GenericDeviceTableEntry Not accessible genericDevicechassisIndex genericDeviceIndex Generic Device Chassis Index Name Object ID Description Syntax Access genericDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 70 1 1 Defines the index one based of this chassis DellObjectRange Read only Generic Device Index Name Object ID Description Syntax Access genericDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 70 1 2 Defines the index of the generic device in this chassis DellObjectRange Read only Generic Device State Capabilities Name Object ID Description Syntax Access genericDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 70 1 3 Defines the capab
320. ge Management It was replaced with RollUpStatus and ComponentStatus for each device Syntax Integer Access Read only Temperature Probe Unit Name temperatureProbeUnit Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 6 Description The units that will be used to display temperatures for the temperature probe Syntax DisplayString Access Read only Temperature Probe Minimum Warning Name temperatureProbeMinWarning Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 7 Description Identifies the minimum temperature that will force the probe into a warning state Syntax Integer Access Read only Temperature Probe Minimum Critical Name temperatureProbeMinCritical Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 8 Description Identifies the minimum temperature that will force the probe into an error state Syntax Integer Access Read only 620 Storage Management Group Temperature Probe Maximum Warning Name temperatureProbeMaxWarning Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 9 Description Identifies the maximum temperature that will force the probe into a warning state Syntax Integer Access Read only Temperature Probe Maximum Critical Name temperatureProbeMaxCritical Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 10 Description Identifies the maximum temperature that will force the probe into an error state Syntax Integer Access Read only Temperature Probe Current Value Name te
321. gent is provided with the operating system For example on supported Microsoft Windows operating systems the Windows SNMP service is the SNMP master agent For information on the versions of the SNMP protocol supported by the SNMP master agent see the operating system documentation SNMP Extension Agent The SNMP extension agent is responsible for registering the MIB objects that it supports with the SNMP master agent and then processing requests from the SNMP master agent for those MIB objects The SNMP extension agent also initiates event notifications to the SNMP master agent The SNMP extension agent does not receive or send standard SNMP protocol messages The SNMP extension agent communicates with the SNMP master agent using an extension protocol defined by the SNMP master agent 30 Introduction The Server Administrator SNMP subagent is an SNMP extension agent Managed Object A managed object is any item in a computer system that can be singled out for discovery monitoring or user intervention and correction K NOTE Not all managed objects described in this guide are supported by all systems A MIB acts as a structured road map for managed objects As an Application Programming Interface API a MIB allows systems management tools to retrieve data maintained by an agent The server administrator MIB is divided into several major groups of managed objects Variable A variable is a component of a managed object A te
322. hat enclosure instance in the enclosure Table The following object sets up the Power Supply Connection Table Name powerSupplyConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 Description Defines the power supply connection table Syntax SEQUENCE OF PowerSupplyConnectionEntry Access Not accessible Power Supply Connection Entry Name powerSupplyConnectionEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 Description Defines the power supply connection table entry Syntax PowerSupplyConnectionEntry Access Not accessible Index powerSupplyConnectionNumber Power Supply Connection Number Name powerSupplyConnectionNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 1 Description Identifies the instance number of the power supply connection entry Syntax Integer Access Read only 616 Storage Management Group Power Supply Connection Power Supply Name Name powerSupplyConnectionPowerSupplyName Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 2 Description Identifies the name of the power supply in this connection as represented in Storage Management Syntax DisplayString Access Read only Power Supply Connection Power Supply Number Name powerSupplyConnectionPowerSupplyNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 3 Description Identifies the instance number of the power supply in the powerSupply Table in the connection Syntax Integer Access Read only Power Supply Connection Enclosure
323. he Remote Access User Administration Table entry RemoteUserAdminTableEntry Not accessible remote UserAdminChassisIndex remoteUserAdminAdapterIndex remoteUserAdminUserIndex Remote Access Group 477 Remote User Admin Chassis Index Name remot eUserAdminChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellObjectRange Access Read only Remote User Admin Adapter Index Name remot eUserAdminAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 2 Description Defines the index one based of the remote access hardware used by this remote access user Syntax DellObjectRange Access Read only Remote User Admin User Index Name remot eUserAdminUserIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 3 Description Defines the index one based of this remote access user Syntax DellObjectRange Access Read only Remote User Admin State Capabilities Name remoteUserAdminStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 4 Description Defines the state capabilities for this remote access user Syntax DellRemoteUserAdminStateCapabilities See Table 19 12 Access Read only 478 Remote Access Group Remote User Admin State Settings Name remoteUserAdminStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 5 Description Defines the state settings for this remote access user Syntax DellRemoteUse
324. he Slot Group provides information about the types of slots that your system supports This management information base MIB group also provides information about the voltages capabilities states and settings that are possible for these slots System Slot Group Table The System Slot Group defines objects in the System Slot MIB table System Slot Table The following object sets up the System Slot Table Name systemSlotTable Object ID 1 3 6 1 4 1 674 10892 1 1200 10 Description Defines the System Slot Table Syntax IntegerSystemStateTableEntry Access Not accessible System Slot Table Entry Name systemSlotTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 Description Defines the System Slot Table entry Syntax IntegerSystemSlot TableEntry Access Not accessible Index systemSlotchassisIndex systemSlotIndex Slot Group 345 System Slot Chassis Index Object ID Description Syntax Access System Slot Index Object ID Description Syntax Access systemSlotchassisIndex 1 3 6 1 4 1 674 10892 1 1200 10 1 1 Defines the index one based of this chassis DellObjectRange Read only systemSlot Index 1 3 6 1 4 1 674 10892 1 1200 10 1 2 Defines the index one based of the system slot in this chassis DellObjectRange Read only System Slot State Capabilities Unique Name Object ID Description Syntax Access systemSlotStateCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1200 10 1 3 Defines the capabilit
325. he hard drive fault LEDs have been reset resetAndEnable 10 The hard drive fault LEDs have been reset and enabled 110 Chassis Information Group Table 5 9 Chassis Identification Control Capabilities Variable Name De11ChassisIdentifyControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The LEDs do not have any chassis identification capabilities unknownCapabilities 1 The chassis identification control s capabilities are unknown enableCapable 2 The chassis identification controls can be disabled offline a binary 0 value or enabled online a binary 1 value notReadyCapable 4 The chassis identification control s capabilities are not ready identifyCapable 8 The chassis identification control s LEDs can be made to identify the chassis NOTE Chassis identification capabilities allow system administrators to set front panel light emitting diodes LEDs to blink when the chassis has malfunctioning components When enabled the blinking lights help administrators locate the problem chassis Table 5 10 Chassis Identification Control Settings Variable Name De11ChassisIdentifyControlSettings Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The chassis identification control s state is unknown enabled 2 The chassis identification control s state is di
326. he index one based of this remote access dial up functionality Syntax DellObjectRange Access Read only Remote Dial Up State Capabilities Name remoteDialUpStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 4 Description Defines the state capabilities of this remote access dial up functionality Syntax DellRemoteDialUpStateCapabilities See Table 19 22 Access Read only Remote Dial Up State Settings Name remoteDialUpStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 5 Description Defines the state settings of this remote access dial up functionality Syntax DellRemoteDialUpStateSettings See Table 19 23 Access Read write Remote Access Group 491 Remote Dial Up Status Name remoteDialUpStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 6 Description Defines the status of this remote access dial up functionality Syntax DellStatus Access Read only Remote Dial Up PPP Dial In Base IP Address Name remoteDialUpPPPDialInBaseIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 7 Description Defines the base IP address of the PPP server for this remote access dial up functionality Syntax IpAddress Access Read write Remote Dial Up PPP Dial In Idle Time out Name remoteDialUpPPPDialInIdleTimeout Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 8 Description Defines the PPP idle time out value in seconds for this remote access dial up functionality Syntax DellUnsigned32BitRange Access Read
327. he processor port DellString Read only Processor Port BIOS Connector Type Name Object ID Description Syntax Access processorPortBlIOSConnectortType 1 3 6 1 4 1 674 10892 1 1000 30 1 9 Defines the BIOS connector type of the processor port DellGenericPortConnectorType Read only PortGroup 233 Memory Device Port Table Name Object ID Description Syntax Access memoryDevicePortTable 1 3 6 1 4 1 674 10892 1 1000 40 Defines the Memory Device Port Table IntegerMemoryDevicePortTableEntry Not accessible Memory Device Port Table Entry Name Object ID Description Syntax Access Index memoryDevicePortTableEntry 1 3 6 1 4 1 674 10892 1 1000 40 1 Defines the Memory Device Port Table entry MemoryDevicePort TableEntry Not accessible memoryDevicePortchassisIndex memoryDevicePortIndex Memory Device Port Chassis Index Name Object ID Description Syntax Access memoryDevicePortchassisIndex 1 3 6 1 4 1 674 10892 1 1000 40 1 1 Defines the index one based of this chassis DellObjectRange Read only Memory Device Port Index Name Object ID Description Syntax Access memoryDevicePortIndex 1 3 6 1 4 1 674 10892 1 1000 40 1 2 Defines the index of the memory device port in this chassis DellObjectRange Read only 234 Port Group Memory Device Port State Capabilities Name memoryDevicePortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 3 Description Defines
328. his system Syntax DellCostofOwnershipString Access Read write 432 Cost of Ownership Group COO Deployment Date Length Name Object ID Description Syntax Access cooDeploymentDateLength 1 3 6 1 4 1 674 10892 1 1600 10 1 20 Defines the deployment time for this system DellUnsigned32BitRange Read write COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 21 Description Defines the deployment time units for this system Syntax DellCooHourDayDurationType See Table 18 2 Access Read write C00 Training Name Name cooTrainingName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 22 Description Defines the training that the user has for this system Syntax DellCostofOwnershipString Access Read write COO Outsourcing Problem Description Name Name Object ID Description Syntax Access cooOutsourcingProblemDescriptionName 1 3 6 1 4 1 674 10892 1 1600 10 1 23 Defines a problem encountered with the outsourcing service provider DellCostofOwnershipString Read write Cost of Ownership Group 433 COO Outsourcing Service Fee Name Name cooOutsourcingServiceFeeName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 24 Description Defines amount that the outsourcing vendor charges for service Syntax DellCostofOwnershipString Access Read write COO Outsourcing Signing Authority Name Name cooOut sourcingSigningAuthorityName Object ID 1 3 6 1 4 1 674 10892
329. ial Port Table Universal Serial Bus USB Port Table Pointing Port Table Name pointingPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 10 Description Defines the Pointing Port Table Syntax IntegerPointingPort TableEntry Access Not accessible Port Group 225 Pointing Port Table Entry Name pointingPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 10 1 Description Defines the Pointing Port Table entry Syntax PointingPortTableEntry Access Not accessible Index pointingPortchassisIndex pointingPortIndex Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Pointing Port Index Name pointingPortIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 10 1 2 Description Defines the index of the pointing ports in this chassis Syntax DellObjectRange Access Read only Pointing Port State Capabilities Name pointingPortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1000 10 3 Description Defines the capabilities of the pointing port Syntax DellStateCapabilities Access Read only 226 Port Group Pointing Port State Settings Name Object ID Description Syntax Access pointingPortStateSettings 1 3 6 1 4 1 674 10892 1 1000 10 4 Defines the state and settings of the pointing port DellStateSettings Read write Pointing Port Status Name Object ID Desc
330. ierarchy For example the status of a lower level object will be propagated up to the status displayed on the Health tab for the top level storage object e Logs an alert into the Alert log and Microsoft Windows application log Sends an Simple Network Management Protocol SNMP trap if the operating system s SNMP service is installed and enabled K NOTE Storage Management does not log alerts regarding the data I O path These alerts are logged by the respective RAID drivers in the system alert log Storage Management Alert Reference 737 Viewing Alerts Storage Management generates alerts that are added to the Windows application alert log and to the Server Administrator Alert log To view these alerts in Server Administrator Select the System object in the tree view Select the Logs tab Select the Alert subtab 1 2 3 K NOTE You can also view these alerts in the Windows Event Viewer Every alert consists of the following e Severity Shows the severity of alert e Date and Time Date and time when Storage Management logged the alert e Description A brief description of the alert To expand or collapse the alert description click the Description column heading Alert Severity Levels Each alert message in the Storage Management alert log has a severity level The severity level is displayed in the Severity field of the alert message The severity level indicates the nature of the alert 738
331. ies of the system slot DellSystemSlotStateCapabilities See Table 14 1 Read only System Slot State Settings Unique Name Object ID Description Syntax Access 346 systemSlotStateSettingsUnique 1 3 6 1 4 1 674 10892 1 1200 10 1 4 Defines the state of the system slot DellSystemSlotStateSettings See Table 14 2 Read only Slot Group System Slot Status Name Object ID Description Syntax Access systemSlotStatus 1 3 6 1 4 1 674 10892 1 1200 10 1 5 Defines the status of the system slot DellStatus Read only System Slot Current Usage Name Object ID Description Syntax Access System Slot Type Name Object ID Description Syntax Access systemSlotCurrentUsage 1 3 6 1 4 1 674 10892 1 1200 10 1 6 Defines the current usage of the system slot DellStatus Read only systemSlotType 1 3 6 1 4 1 674 10892 1 1200 10 1 7 Defines the type of the system slot DellSystemSlotType See Table 14 3 Read only System Slot External Slot Name Name Object ID Description Syntax Access systemSlotSlotExternalSlotName 1 3 6 1 4 1 674 10892 1 1200 10 1 8 Defines the external connector name of the system slot DellString Read only Slot Group 347 System Slot Length Object ID Description Syntax Access systemSlotLength 1 3 6 1 4 1 674 10892 1 1200 10 1 9 Defines the length of the system slot DellSystemSlotLength See Table 14 5 Read only System Slot Slot ID Name syst
332. igned32BitRange Access Read write COO Support Information Help Desk Name Name cooSupportInformationHelpDeskName Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 6 Description Defines the help desk information provided Syntax DellCostofOwnershipString Access Read write COO Support Information Fix Type Name Name cooSupportiInformationFixTypeName Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 7 Description Defines the method used to fix the problem Syntax DellCostofOwnershipString Access Read write COO Trouble Ticket Table The MIB objects in the Trouble Ticket Table enable you to track details of any trouble tickets that you open for your system Name cooTroubleTicketTable Object ID 1 3 6 1 4 1 674 10892 1 1600 110 Description Defines the COO Trouble Ticket Table Syntax SEQUENCE OF cooTroubleTicketTableEntry Access Not accessible 456 Cost of Ownership Group COO Trouble Ticket Table Entry Name Object ID Description Syntax Access Index cooTroubleTicketTableEntry 1 3 6 1 4 1 674 10892 1 1600 110 1 Defines the COO Trouble Ticket Table entry coo TroubleTicketTableEntry Not accessible coo TroubleTicketchassisIndex cooTroubleTicketIndex COO Trouble Ticket Chassis Index Name cooTroubleTicketchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 110 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only COO Trouble Ticket Index Name cooTroubleTicket In
333. igned32BitRange Access Read write Remote Access Group _ 493 Remote Dial Up Modem Port Name Object ID Description Syntax Access remoteDialUpModemPort 1 3 6 1 4 1 674 10892 1 1700 40 1 14 Defines the port for the modem used by this remote access dial up functionality DellUnsigned32BitRange Read write Remote User Dial In Configuration Table Name Object ID Description Syntax Access remoteUserDialiInCfgTable 1 3 6 1 4 1 674 10892 1 1700 50 Defines the Remote Access User Dial In Configuration Table SEQUENCE OF RemoteUserDiallnCfgTableEntry Not accessible Remote User Dial In Configuration Table Entry Name Object ID Description Syntax Access Index remoteUserDialiInCfgTableEntry 1 3 6 1 4 1 674 10892 1 1700 50 1 Defines the Remote Access User Dial In Configuration Table entry RemoteUserDiallnCfgTableEntry Not accessible remote UserDiallnCfgChassisIndex remoteUserDiallnCfgAdapterIndex remoteUserDiallnCfgUserIndex 494 Remote Access Group Remote User Dial In Configuration Chassis Index Name remoteUserDialInCfgChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellObjectRange Access Read only Remote User Dial In Configuration Adapter Index Name remoteUserDialInCfgAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 2 Description Defines the index o
334. ilities Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 SD card device has none of the following capabilities sdCapable 1 SD media can be enabled vF LlashCapable 2 Virtual Flash vFlash can be enabled Device Group 343 Table 13 28 SD Card Device Config Settings Variable Name Data Type Integer DellSDCardDeviceConfigSettings NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 sd vF lash Fnabled 1 Fnabled 2 SD card device has none of the following settings SD media is enabled Virtual Flash vFlash is enabled Table 13 29 SD Card Device Card State Variable Name Data Type Integer DellSDCardDeviceCardState NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 present 1 ipmiReady 2 fullReady 4 offline 8 failed 16 active 32 bootable 64 writeProtect 128 standby 256 SD card state is none of the following states Device is present Device is IPMI ready Device is full ready Device is offline Device is failed Device is active Device is bootable Device is write protected Device is in standby mode 344 Device Group Slot Group T
335. ilities Access Read only System Resource DMA State Settings Name systemResourceDMAStateSettings Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 4 Description Defines the state and setting of this system resource DMA Syntax DellStateSettings Access Read write System Resource DMA Status Name systemResourceDMAStatus Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 5 Description Defines the status of this system resource DMA Syntax DellStatus Access Read only 142 System Resource Group System Resource DMA Owner Index Reference Name Object ID Description Syntax Access systemResourceDMAOwnerIndexReferenc 1 3 6 1 4 1 674 10892 1 500 60 1 6 Defines the index to the associated system resource owner in this chassis DellObjectRange Read only System Resource DMA Share Disposition Name Object ID Description Syntax Access systemResourceDMAShareDisposition 1 3 6 1 4 1 674 10892 1 500 60 1 7 Defines the share disposition of the system resource DMA DellResourceShareDisposition See Table 7 3 Read only System Resource DMA Maximum Transfer Size Name Object ID Description Syntax Access systemResourceDMAMaximumTransferSize 1 3 6 1 4 1 674 10892 1 500 60 1 8 Defines the maximum size of a memory transfer in bytes for the system resource DMA DellUnsigned32BitRange Read only System Resource DMA Transfer Width Name Object ID Description Syntax Access systemResourceDMATransferWid
336. ilities of the generic device DellStateCapabilities Read only Device Group 293 Generic Device State Settings Name Object ID Description Syntax Access genericDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 70 1 4 Defines the state of the generic device DellStateSettings Read write Generic Device Status Name Object ID Description Syntax Access genericDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 70 1 5 Defines the status of the generic device DellStatus Read only Generic Device System Slot Index Reference Name Object ID Description Syntax Access genericDeviceSystemSlotIndexReference 1 3 6 1 4 1 674 10892 1 1100 70 1 6 Defines the index of the system slot into which this generic device is plugged DellObjectRange Read only Generic Device Type Name Object ID Description Syntax Access 294 genericDeviceTyp 1 3 6 1 4 1 674 10892 1 1100 70 1 7 Defines the type of the generic device DellGenericDeviceType See Table 13 18 Read only Device Group Generic Device Name Name genericDeviceNam Object ID 1 3 6 1 4 1 674 10892 1 1100 70 1 8 Description Defines the name of the generic device Syntax DellString Access Read only PCI Device Table Name pCIDeviceTable Object ID 1 3 6 1 4 1 674 10892 1 1100 80 Description Defines the PCI Device Detail Table Syntax SEQUENCE OF PCIDeviceTableEntry Access Not accessible PCI Device Table Entry Na
337. in response to a user request Traps 725 Table 26 19 Enterprise specific Traps continued Trap Name Description Severity Category Cause Supported ID by RAC Platform 1002 alertDrscAuth RAC Minor Error RAC login All Error Authentica failure caused tion by failures authenticatio during a n failure time number of period concurrent have logins exceed exceededa limit or threshold permission denied 1003 alertDrscLost The RAC Critical Error RAC lost Dell ESM cannot communicati Remote communicate on with ESM Access with the Controller baseboard DRAC III management controller ESM 1004 alertDrscFound The RAC is Information Error RAC DRAC III ESM communicat recovered ing communicati normally on with ESM with the baseboard management controller ESM 726 Traps Table 26 19 Enterprise specific Traps continued Trap Name Description Severity Category Cause Supported ID by RAC Platform 1005 alertDrscPower The RAC Critical Error RAC DRAC III Off has detected a detecteda system power system state change power to power off state change to powered off 1006 alertDrscPower The RAC Information Error RAC DRAC III On has detected a detected a system power system state change power to power on state change to powered on 1007 alertDrsc The RAC Critical Event RAC has DRAC III Watchdog has detected the Expired detected system that the watchdog system expired watchdog normally has
338. in trademarks and trade names other than its own December 2009 Contents 1 Introduction oana Ot tn dae 19 Audience 0 000 ee eae 19 What s New inthis Release 19 Supported SNMP Versions 19 What s New in System StateGroup 19 What s New in Device Group 20 What s NewinTraps 21 What s New in Power Group 21 Introduction to the SNMP Reference Guide 22 General Content 23 Server Administrator Instrumentation MIB 23 Server Administrator Remote Access MIB 25 Server Administrator Baseboard Management Controller ASFMIB 26 Server Administrator Field Replaceable Unit MIB siss eae rein ea arpa Ge 26 Server Administrator Storage Management MIB noaa aaa aaa aa 27 Server Administrator Change Management MIB 28 Dell RAC Out of BandMIB 28 How This Guide Defines Technical Terms 29 SNMP Basic Terminology 30 Frequently Used Terms in Variable Names 33 Tables secer an h aa naa 33 Reference Guide Content Tables 36 Section Organization oaaae 36 Contents Other Documents You May Need Introduction to the Server Administrator SNMP Subagent SNMPMIBOIDs SNMP Security 0 Management Actions SNMP Traps 00000 2 Instrumentation MIB Version Group
339. ines if the processor serial number can be returned Syntax DellStateCapabilities Access Read only BIOS Setup Control Processor Serial Number Control Settings Name bSUCprocessorSerialNumberControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 11 Description Defines the state of the processor serial number Syntax DellStateSettings Access Read only 386 BIOS Setup Control Group BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 12 Description Defines the status of the processor serial number Syntax DellStatus Access Read only BIOS Setup Control Processor Serial Number Control Name Name bSUCprocessorSerialNumberControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 13 Description Defines the setup BIOS name of the processor serial number Syntax DellString Access Read write BIOS Setup Control Speaker Control Capabilities Unique Name bSUCspeakerControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 14 Description Defines the capabilities of the speaker control Syntax DellSpeakerControlCapabilities Unique See Table 16 1 Access Read only BIOS Setup Control Speaker Control Settings Unique Name bSUCspeakerControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 15 Description Defines the settings available for speaker control Syntax DellSpeakerControlSettingsUnique See Table 16 2 Ac
340. ines the setup BIOS name of the diskette controller Syntax DellString Access Read only Network Interface Control Table These MIB objects enable you to track the attributes of the NIC card for your system Name networkInterfaceControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 80 Description Defines the Network Interface Control Table Syntax NetworkInterfaceContro TableEntry Access Not accessible 406 BIOS Setup Control Group Network Interface Control Table Entry Name Object ID Description Syntax Access Index networkInterfaceControlTableEntry 1 3 6 1 4 1 674 10892 1 1400 80 1 Defines the Network Interface Control Table entry NetworkInterfaceControl TableEntry Not accessible networkInterfaceControlchassisIndex networkInterfaceControlIndex Network Interface Control Chassis Index Name Object ID Description Syntax Access networkInterfaceControlchassisIndex 1 3 6 1 4 1 674 10892 1 1400 80 1 1 Defines the index one based of this chassis DellObjectRange Read only Network Interface Control Index Name Object ID Description Syntax Access networkInterfaceControlIndex 1 3 6 1 4 1 674 10892 1 1400 80 1 2 Defines the index one based of the network interface controller in this chassis DellObjectRange Read only BIOS Setup Control Group 407 Network Interface Control Capabilities Unique Name networkInterfaceControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1
341. ing unknown 2 The remote user alphanumeric baud rate is unknown alphaBaud300 3 The remote user alphanumeric baud rate is 300 alphaBaud1200 4 The remote user alphanumeric baud rate is 1200 Table 19 18 Remote SNMP Trap State Capabilities Variable Name De 1 1RemoteSNMPTrapStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The SNMP trap destination has no state capabilities unknownCapabilities 1 The SNMP trap destination state capabilities are unknown enableCapable 2 The SNMP trap destination can be disabled or enabled notReadyCapable 4 The SNMP trap destination can be in the not ready state Table 19 19 Remote SNMP Trap State Settings Variable Name De 1 1RemoteSNMPTrapStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The SNMP trap destination has no state settings unknown 1 The SNMP trap destination state settings are unknown enabled 2 The SNMP trap destination is enabled notReady 4 The SNMP trap destination is in the not ready state Remote Access Group 509 Table 19 20 Remote SNMP Trap Control Capabilities Variable Name De 1 1RemoteSNMPTrapControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The SNMP trap destination has no control capabilities unk
342. ing enhances higher availability scalability and management Higher availability is achieved by using failover clusters in which resources can automatically move between two or more systems in the event of a failure Scalability is achieved by balancing the load of an application across several computer systems Simpler management is achieved by using virtual servers as opposed to managing each individual computer system Cluster Group The Cluster Group defines attributes such as the number of systems in the cluster capabilities of the cluster type of cluster and name of the cluster Cluster Table The following table defines the attributes of the cluster Name clusterTable Object ID 1 3 6 1 4 1 674 10892 1 1800 10 Description Defines the Cluster Table Syntax SEQUENCE OF ClusterTableEntry Access Not accessible Cluster Table Entry Name clusterTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 Description Defines the Cluster Table entry Syntax Cluster TableEntry Access Not accessible Index clusterChassisIndex clusterIndex Cluster Group 517 Cluster Chassis Index Name clusterChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Cluster Index Name clusteriIndex Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 2 Description Defines the index one based of the cluster Syntax DellObjectRange Access
343. ing subsections 22 Introduction General Content Table 1 1 describes the sections that provide general information about the MIBs documented in this guide Table 1 1 General Content Sections in This Guide Section Topics MIB Group Number 1 Introduction to SNMP basics and to the MIBs that NA support Server Administrator services 26 Traps describes in band traps defined in the Server 5000 Administrator Instrumentation MIB and out of band traps sent by the Remote Access Controller RAC and Baseboard Management Controller BMC AppendixA Standard Data Type Definitions defines standard NA data types used in this reference guide AppendixB SNMP Sample Output provides a sample SNMP NA output Server Administrator Instrumentation MIB The Server Administrator Instrumentation MIB filename 10892 mib provides instrumentation data that allows you to monitor the health of a system with SNMP management applications It provides e Information about the status of temperatures power supplies voltages currents fans and memory at key points in the system e Rapid access to detailed fault and performance information gathered by industry standard systems management agents e Version information for Basic Input Output System BIOS firmware and operating system e A detailed account of every cost of ownership COO detail about your system In addition traps are sent to report a change in status
344. inology It is important to have a good understanding of the key technical terms used in this guide This guide provides definitions for all essential terms used in describing the Server Administrator MIBs For definitions on all essential terms and acronyms see the Glossary available on the Dell Support website at support dell com manuals SNMP Master Agent Typically the SNMP agent on a managed system consists of one SNMP master agent and zero or more SNMP extension agents This SNMP agent extendable structure facilitates the addition of new MIB modules without having to rebuild the entire SNMP agent and is invisible to SNMP management applications The SNMP master agent is responsible for receiving SNMP request protocol messages from SNMP management applications and sending SNMP response protocol messages As part of processing SNMP request protocol messages the SNMP master agent typically communicates with one or more SNMP extension agents This communication does not involve standard SNMP protocol messages The SNMP master agent uses an extension protocol that shields the SNMP extension agent from the standard SNMP protocol messages The extension protocol also provides a way for SNMP extension agents to send SNMP event notifications called traps in SNMPv1 The SNMP master agent is also responsible for sending SNMP event notification protocol messages to SNMP management applications On supported operating systems the SNMP master a
345. ion Defines the LRA Action Table Syntax SEQUENCE OF LRAActionTableTableEntry Access Not accessible LRA Action Table Entry Name LRAActionTableTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1500 20 1 Description Defines the LRA Action Table entry Syntax LRAActionTableTableEntry Access Not accessible Index IRAActionTablechassisIndex IRAAction TableActionNumberIndex LRA Action Table Chassis Index Name 1RAActionTablechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1500 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only 422 Local Response Agent Group LRA Action Table Action Number Index Name 1RAActionTableAct ionNumberIndex Object ID 1 3 6 1 4 1 674 10892 1 1500 20 1 2 Description Defines the LRA action number index The action number indexes are as follows 160 temperature failure action definition 168 cooling device failure action definition 172 voltage failure action definition 200 temperature warning action definition 202 voltage warning action definition 204 cooling device warning action definition 206 amperage failure action definition 208 amperage warning action definition 210 a power or cooling unit redundancy lost action definition 212 a power or cooling unit redundancy degraded action definition 214 power supply failed action definition 220 chassis intrusion action definition 228 memory device war
346. ion This entry is obsolete for Storage Management Syntax DisplayString Access Read only Storage Management Group 579 Enclosure Type Name enclosureType Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 16 Description Indicates the type of the enclosure Possible values 1 Internal 2 Dell PowerVault 200S PowerVault 201S 3 Dell PowerVault 210S PowerVault 211S 4 Dell PowerVault 220S PowerVault 221S 5 6 7 8 9 Dell PowerVault 660F Dell PowerVault 224F Dell PowerVault 660F PowerVault 224F Dell MD1000 Dell MD1120 Syntax DisplayString Access Read only Enclosure Processor2 Version Name enclosureProcessor2Version Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 17 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only 580 Storage Management Group Enclosure Configuration Name Object ID Description Syntax Access enclosureConfig 1 3 6 1 4 1 674 10893 1 20 130 3 1 18 Identifies the current configuration of the enclosure s backplane Possible values 1 Joined 2 Split Bus 3 Clustered 4 Unified Integer Read only Enclosure Channel Number Name Object ID Description Syntax Access enclosureChannelNumber 1 3 6 1 4 1 674 10893 1 20 130 3 1 19 Identifies the channel number or bus to which the enclosure is connected Integer Read only Enclosure Alarm Name Object ID Description Syntax Ac
347. ionModeCapabilities Access Read only BMC Serial Interface Connection Mode Settings Name bmcSerialInterfaceConnectionModeSettings Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 9 Description Defines the connection mode settings of the BMC serial interface Syntax DellBMCSerialConnectionModeSettings Access Read only BMC Serial Interface Flow Control Name bmcSerialInterfaceFlowControl Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 10 Description Defines the flow control type of the BMC serial interface Syntax DellBMCSerialFlowControl Type Access Read only BMC Serial Interface Bit Rate Name bmcSerialInterfaceBitRate Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 11 Description Defines the bit rate of the BMC serial interface Syntax DellBMCSerialBitRateType Access Read only 528 Baseboard Management Controller Group Baseboard Management Controller LAN Interface Table Name bmcLANInterfaceTable Object ID 1 3 6 1 4 1 674 10892 1 1900 30 Description Defines the Baseboard Management Controller BMC LAN Interface Table Syntax SEQUENCE OF BmcLANInterfaceTableEntry Access Not accessible BMC LAN Interface Table Entry Name bmcLANInterfaceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 Description Defines the Baseboard Management Controller BMC LAN Interface Table Entry Syntax BmcLANIntertaceTableEntry Access Not accessible Index bmcLANInterfaceChassisIndex bmcLANInterfaceBMCIndex bmcLANInterfaceIndex
348. ip Group 429 COO Acquisition Signing Authority Name Name cooAquisitionSigningAuthorityName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 8 Description Defines the name of the authorized person who signs for the system Syntax DellCostofOwnershipString Access Read write COO Original Machine Configuration Expensed Name cooOriginalMachineConfigurationExpensed Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 9 Description Specifies whether the purchase of this system was expensed Syntax DellBoolean Access Read write COO Original Machine Configuration Vendor Name Name cooOriginalMachineConfigurationVendorName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 10 Description Defines the vendor name of the system Syntax DellCostofOwnershipString Access Read only COO Cost Center Information Vendor Name Name cooCostCenterInformationVendorName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 11 Description Defines the cost center name of the system Syntax DellCostofOwnershipString Access Read write 430 Cost of Ownership Group COO User Information User Name Name Object ID Description Syntax Access cooUserInformationUserName 1 3 6 1 4 1 674 10892 1 1600 10 1 12 Defines the name of the user for this system DellCostofOwnershipString Read write COO Extended Warranty Start Date Name Name Object ID Description Syntax Access cooExtendedWarrantyStartDateName 1 3 6 1 4 1 674 10892 1 1600 10 1 13 Defines the
349. iption Syntax Access systemResourcelInterruptTrigger 1 3 6 1 4 1 674 10892 1 500 50 1 10 Defines the interrupt trigger of the system resource interrupt DellResourcelnterruptTrigger See Table 7 6 Read only System Resource Direct Memory Access DMA Table Name Object ID Description Syntax Access systemResourceDMATable 1 3 6 1 4 1 674 10892 1 500 60 Defines the System Resource DMA Table SEQUENCE OF SystemResourceDMATableEntry Not accessible System Resource DMA Table Entry Name Object ID Description Syntax Access Index systemResourceDMATable 1 3 6 1 4 1 674 10892 1 500 60 1 Defines the System Resource DMA Table entry SystemResourceDMATableEntry Not accessible systemResourceDMAchassisIndex systemResourceDMAIndex System Resource DMA Chassis Index Name Object ID Description Syntax Access systemResourceDMAchassisIndex 1 3 6 1 4 1 674 10892 1 500 60 1 1 Defines the index one based of this chassis DellObjectRange Read only System Resource Group 141 System Resource DMA Index Name systemResourceDMAIndex Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 2 Description Defines the index of system resource DMAs in this chassis Syntax DellObjectRange Access Read only System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 3 Description Defines the capabilities of this system resource DMA Syntax DellStateCapab
350. iption Defines the Operating System Memory Table entry Syntax OperatingSystemMemoryTableEntry Access Not accessible Index operatingSystemMemorychassisIndex Operating System Memory Chassis Index Name operatingSystemMemorychassisIndex Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Operating System Memory State Capabilities Name operatingSystemMemoryStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 2 Description Defines the capabilities of the operating system memory Syntax DellStateCapabilities Access Read only Operating System Memory State Settings Name operatingSystemMemoryStateSettings Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 3 Description Defines the state and allows the setting of the operating system memory Syntax DellStateSettings Access Read write 124 Operating System Group Operating System Memory Status Name operatingSystemMemoryStatus Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 4 Description Defines the status of the operating system memory Syntax DellStatus Access Read only Operating System Memory Total Physical Size Name operatingSystemMemoryTotalPhysicalSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 5 Description Defines the total physical memory size in kilobytes Syntax DellUnsigned32BitRange Access Read only Operating System Memory Available Physical Size Name operatin
351. is the theoretical maximum power drawn by the power supply minus peak power draw DellUnsigned32BitRange 180 Power Group Name powerUsagePeakHeadroom Access Read only Power Profile Table Name powerProfileTable Object ID 1 3 6 1 4 1 674 10892 1 600 70 Description Defines the Power Profile Table Syntax SEQUENCE OF PowerProfileTableEntry Access Not accessible Power Profile Table Entry Name powerProfileTableEntry Object ID 1 3 6 1 4 1 674 10892 1 600 70 1 Description Defines the Power Profile Table Entry Syntax PowerProfileTableEntry Access Not accessible Index powerProfileChassisIndex powerProfileIndex Power Profile Chassis Index Name powerProfileChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 70 1 1 Description Defines the index one based of the associated chassis Syntax DellObjectRange Access Read only Power Profile Index Name powerProfileIndex Object ID 1 3 6 1 4 1 674 10892 1 600 70 1 2 Description Defines the index one based of the power profile information Power Group 181 Name powerProfileIndex Syntax DellObjectRange Access Read only Power Profile Supported Profiles Name powerProfileSupportedProfiles Object ID 1 3 6 1 4 1 674 10892 1 600 70 1 3 Description Defines the supported power profiles Syntax DellPowerProfileType Access Read only Power Profile Setting Name powerProfileSetting Object ID 1 3 6 1 4 1 674 10892 1 600 70 1 4 Description Defines the power profile
352. is warning noncritical critical 5 The object s status is critical failure nonRecoverable 6 The object s status is nonrecoverable dead Table A 6 Dell Status Redundancy Variable Name De11StatusRedundancy Data Type Integer Possible Data Values Meaning of Data Value other 1 The object s status is not one of the following unknown 2 The object s redundancy status is unknown full 3 The object is fully redundant degraded 4 The object s redundancy has been degraded lost 5 The object s redundancy has been lost notRedundant 6 Redundancy does not apply or it is not redundant 746 Standard Data Type Definitions Table A 7 Dell Status Probe Variable Name De11StatusProbe Data Type Integer Possible Data Values Meaning of Data Value other 1 The object s status is not one of the following unknown 2 The status of the object is unknown ok 3 The status of the object is OK nonCriticalUpper 4 The object is at the noncritical upper limit CriticalUpper 5 The object is at the critical upper limit nonRecoverableUpper 6 The object is at the nonrecoverable upper limit nonCriticalLower 7 he object is at the noncritical lower limit criticalLower 8 he object is at the critical lower limit nonRecoverableLower 9 The object is at the nonrecoverable lower limit T T T failed 10 T Dell Date he s
353. it is less than a megabyte Syntax Integer Access Read only Array Disk Largest Contiguous Free Space in Bytes Name arrayDiskLargestContiguousFreeSpacelInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 14 Description The size of the largest contiguous free space on this array disk in bytes that is less than a megabyte This size plus the arrayDiskLargestContiguousFreeSpaceInMB is the total size of the largest contiguous free space on the array disk Syntax Integer Access Read only Array Disk Target ID Name arrayDiskTargetID Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 15 Description Identifies the SCSI target ID which this array disk is assigned Syntax Integer Access Read only Array Disk LUN ID Name arrayDiskLunID Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 16 Description Identifies the array disk s logical unit number Syntax Integer Access Read only 590 Storage Management Group Array Disk Used Space in Megabytes Name arrayDiskUsedSpaceInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 17 Description Identifies the amount in megabytes of the used space on the array disk If this size is 0 it is smaller than a megabyte Syntax Integer Access Read only Array Disk Used Space in Bytes Name arrayDiskUsedSpaceInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 18 Description Identifies the size in bytes of the used space on the array disk that is smaller than a megabyte This size plus the arrayDis
354. ject ID 1 3 6 1 4 1 674 10892 1 300 20 Description Defines the UUID table Syntax SEQUENCE OF UUIDTableEntry Access Not accessible UUID Table Entry Name uUIDTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 Description Defines the UUID table entry Syntax UUIDTableEntry Access Not accessible Index uUID Index uUIDchassisIndex 34 Introduction UUID Chassis Index Name Object ID Description Syntax Access UUID Index Name Object ID Description Syntax Access UUID Type Name Object ID Description Syntax Access UUID Value Name Object ID Description Syntax Access uUIDchassisIndex 1 3 6 1 4 1 674 10892 1 300 20 1 1 Defines the index one based of this chassis DellObjectRange Read only uUIDIndex 1 3 6 1 4 1 674 10892 1 300 20 1 2 Defines the index of the UUID in a specified chassis DellObjectRange Read only uUIDType 1 3 6 1 4 1 674 10892 1 300 20 1 3 Defines the type of the UUID for this chassis DellUUIDType Read only uUIDValue 1 3 6 1 4 1 674 10892 1 300 20 1 4 Defines the value of the UUID for this chassis OCTET STRING SIZE 16 Read only Introduction 35 Reference Guide Content Tables K NOTE Variable values are defined for any variable that is Server Administrator specific Industry standard variable definitions are documented in Standard Data Type Definitions Some of the tables in this guide have no technical significance in SNMP These tables
355. kUsedSpaceInMB is the total amount of used space on the array disk Syntax Integer Access Read only Array Disk Free Space in Megabytes Name arrayDiskFreeSpaceInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 19 Description Identifies the amount in megabytes of the free space on the array disk If this size is 0 it is smaller than a megabyte Syntax Integer Access Read only Storage Management Group 591 Array Disk Free Space in Bytes Name arrayDiskFreeSpaceInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 20 Description Identifies the size in bytes of the free space on the array disk that is smaller than a megabyte This size plus the arrayDiskFreeSpaceInMB is the total amount of free space on the array disk Syntax Integer Access Read only Array Disk Bus Type Name arrayDiskBusType Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 21 Description Identifies the bus type of the array disk Possible values 1 SCSI 2 IDE 3 Fibre Channel 4 SSA 6 USB 7 SATA 8 SAS Syntax Integer Access Read only 592 Storage Management Group Array Disk Spare State Name Object ID Description Syntax Access arrayDiskSpareState 1 3 6 1 4 1 674 10893 1 20 130 4 1 22 Identifies the status of the array disk as a spare Possible states 1 Disk is a member of a virtual disk 2 Disk is a member of a disk group 3 Disk is a global hot spare 4 Disk is a dedicated hot spare 5 Not a spare 99 Not applicable
356. l supportsPMEand3P3Vand5VandHotPlugg able 16770 The system slot supports power management enable supportsPMEand3P3Vand5VhasAdapterO n 1 6804 The system slot supports power management event PME supplies 3 3 V and supplies 5 V The adapter is on supportsPMEand3P3Vand5VhasAdapter OnandisHotPluggable 16806 The system slot supports PME supplies 3 3 V and supplies 5 V The adapter is on and the system slot is hot pluggable supportsPMEand3P3VIsSharedand5Vhas AdapterOnandisHotPluggable 17316 The system slot supports PME supplies 3 3 V supplies 5 V and shares a slot opening The adapter is on and the system slot is hot pluggable 352 Slot Group Table 14 3 System Slot Type Variable Name De11SystemSlotType Data Type Integer Possible Data Values Meaning of Data Value systemSlotIsOther 1 The system slot type is not one of following systemSlotIsUnknown 2 The system slot type is unknown systemSlotIsISA 3 The system slot is Industry Standard Architecture ISA systemS1lotIsMCA 4 The system slot is Micro Channel Architecture MCA systemSlotIsEISA 5 The system slot is Extended Industry Standard Architecture EISA systemSlotIsPCI 6 The system slot is Peripheral Component Interconnect PCI systemSlotIsPCMCIA 7 The system slot is compliant with the Personal Comput
357. l Group Variable Values 211 10 User Security Group 215 User Security Group Table 215 User Security Table 215 11 Remote Flash BIOS Group 219 Remote Flash BIOS Group Table 219 Remote Flash BIOS Table 219 Remote Flash BIOS Variable Values 222 12 POreGroup s i445 4 2 2644 eet eee 225 PortGroupTables 225 Pointing PortTable 225 Keyboard PortTable 228 Processor PortTable 231 Memory Device PortTable 234 Monitor PortTable 237 Small Computer System Interface SCSI Port Tabl cse 3 es vio Bee Qo RS 240 Parallel Port Table 242 Serial Port Table 246 Universal Serial Bus USB Port Table 250 Port Group Variable Values 253 13 Device Group 259 Device Tables 259 Contents Pointing Device Table 260 Keyboard Device Table 262 Processor Device Table 265 Processor Device Status Table 273 Cache Device Table 275 Memory Device Table 281 Memory Device Mapped Address Table 289 Generic Device Table 292 PCI DeviceTable 295 PCI Device Configuration Space Table 298 Network Device Table 301 Managed S
358. l Table Network Interface Control Table BIOS Setup Control Table Name biosSetUpControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 10 Description Defines the set of single devices in a chassis controlled by the BIOS Syntax BiosSetUpControlTableEntry Access Not accessible BIOS Setup Control Group 383 BIOS Setup Control Table Entry Name biosSetUpControlTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 Description Defines the BIOS Control Device Table entry Syntax BiosSetUpControl TableEntry Access Not accessible Index biosSetUpControlchassisIndex BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only BIOS Setup Control BSUC Pointing Device Control Capabilities Name bSUCpointingDeviceControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 2 Description Defines the capabilities of the pointing device Syntax DellStateCapabilities Access Read only BIOS Setup Control Pointing Device Control Settings Name bSUCpointingDeviceControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 3 Description Defines the state of the pointing device Syntax DellStateSettings Access Read write 384 BIOS Setup Control Group BIOS Setup Control Pointing Device Control Status Name bSUCpointingDeviceControlStatus Object ID 1 3 6 1 4 1 674 1089
359. l details for the events gt Specifies possible additional details about the specified device for example Additional details Memory device number DIMM_1A Serial TEITLITL Memory device number DIMM_1B Serial 22222222 lt Additional power supply status information gt Specifies any additional power supply information pertaining to the event for example Power supply input AC is off Power supply POK power OK signal is not normal Power supply is turned off Battery sensor status lt status gt Traps Specifies the status reported by the battery sensor for example Battery sensor status Predictive failure Table 26 1 Trap Description Reference continued Description Line Item Explanation Chassis intrusion state lt Intrusion state gt Specifies the chassis intrusion state open or closed for example Chassis intrusion state Open Chassis location lt Name of chassis gt Specifies the name of the chassis that generated the message for example Chassis location Main System Chassis Configuration error type lt type of configuration error gt Specifies the type of configuration error that occurred for example Configuration error type Revision mismatch Current sensor value in Amps lt Reading gt Specifies the current sensor value in amps for example Current sensor value 7 853 Date and time of action lt Date
360. le Possible Data Values Meaning of Data Value configurationError 32 The processor experienced a configuration error processorPresent 128 The processor is present processorDisabled 256 The processor is disabled terminatorPresent 512 The terminator is Present processorThrottled 1024 The processor is throttled Table 13 4 Processor Device Type Variable Name De 1 1ProcessorDeviceTyp Data Type Integer Possible Data Values Meaning of Data Value deviceTypelsOther 1 The processor device type is not one of the following values deviceTypeIsUnknown 2 The processor device type is unknown deviceTypeIsCPU 3 The processor device type is a central processing unit deviceTypeIsMathProcessor 4 The processor device type is a math processor deviceTypelIsDSP 5 The processor device type is a digital signal processor deviceTypeIsAVideoProcessor 6 The processor device is a video processor Device Group 319 Table 13 5 Processor Upgrade Information Variable Name De 1 1ProcessorUpgradeInformation Data Type Integer Possible Data Values Meaning of Data Value processorUpgradeIsOther 1 The upgrade device type is not one of the following processorUpgradelIsUnknown 2 pgrade device type is nknown L u processorUpgradeIsByDaughterBoard 3 Ll pgrade device is on a d aughter board processo
361. le 13 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsAlpha21364 55 The processor family is Alpha 21364 deviceFamilyIsAMDTurionIIUltra DualMobileM 56 The processor family is AMD Turion TM II Ultra Dual Core Mobile M Processor Family deviceFamilyIsAMDTurionIIDualM obileM 57 The processor family is AMD Turion TM I Dual Core Mobile M Processor Family deviceFamilyIsAMDAthlonIIDualM obileM 58 The processor family is AMD Athlon TM II Dual Core Mobile M Processor Family deviceFamilyIsAMDOpteron6100 5 9 The processor family is AMD Opteron TM 6100 Series Processor deviceFamilyIsMIPS 64 The processor family is MIPS deviceFamilyIsMIPSR4000 65 The processor family is MIPS R4000 deviceFamilyIsMIPSR4200 66 The processor family is MIPS R4200 deviceFamilyIsMIPSR4400 67 The processor family is MIPS R4400 deviceFamilyIsMIPSR4600 68 The processor family is MIPS R4600 H deviceFamilyIsMIPSR10000 69 The processor family is MIPS R10000 deviceFamilyIsSPARC 80 The processor family is SPARC deviceFamilyIsSuperSPARC 81 The processor family is SuperSPARC deviceFamilyIsmicroSPARCII 82 The processor family is microSPARC II deviceFamilyIsmicroSPARCIIep 83 The
362. le 14 1 System Slot State Capabilities Variable Name De11SystemSlotStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value systemSlotHotPlugisUnknown The system slot s capabilities are unknown 1 systemSlotHotPlugIsHotPlug The system slot supports hot plug gableCapable 2 systemSlotHotPlugCanBePower The system slot power and corresponding edon 4 light emitting diode LED can be powered on SlotGroup 349 Table 14 1 System Slot State Capabilities continued Variable Name De11SystemSlotStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value systemSlotHotPlugCanSignal Attention 8 The system slot attention state and corresponding LED can be set systemSlo PowerFaul HotPlugCanSignal Power on fault and corresponding LED can be detected due to a short or overcurrent U systemSlotHotPlugCanSignal AdapterPresent 32 Adapter card present in slot may not be powered can be detected systemSlotHotPlugCanSignal PowerButtonPressed 64 The system slot power button can be pressed to signal a toggle of the power state canSupportAllHotPlugCapabi lities 126 The system slot can support all hot plug capabilities systemSlotHotPlugIsUnknown 1 The system slot s capabilities are unknown systemSlotCanProvide5Volts 128 The system slot can provide a 5 volt V s
363. letters The following variable names illustrate these conventions temperatureProbeLowerCriticalThreshold coolingUnitIndex pCIDeviceSpeed Object Identifier OID is the unique number assigned to an object defined in a MIB An OID is written as a sequence of subidentifiers in decimal notation Each OID in this reference guide has a prefix that identifies the managed objects as belonging to Dell 1 3 6 1 4 1 674 The additional numbers identify the MIB group and subgroup as well as the table entry number of any variables For example the OID for the temperature probe managed object table is 700 20 and the variable for the location of the temperature probe temperature ProbeLocationName has an OID of 700 20 1 8 The full OIDs for these items are 1 3 6 1 4 1 674 10892 1 700 20 for the temperatureProbeTable and 1 3 6 1 4 1 674 10892 1 700 20 1 8 for the temperatureProbeLocation For more information about the structure of OIDs see SNMP MIB OIDs Description is a brief explanation of what a particular managed object does Syntax defines the data type in which the values of the variable must be expressed Most variables in this reference guide use standard data types such as string or boolean All data types that are unique to server administrator variables are defined at the end of the section in which they occur Standard data types are defined in Standard Data Type Definitions Access specifies whether persons with a
364. lingDeviceTable Object ID 1 3 6 1 4 1 674 10892 1 700 12 Description Defines the Cooling Device Table Syntax CoolingDevice TableEntry Access Not accessible Cooling Device Table Entry Name coolingDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 Description Defines the Cooling Device Table entry Syntax CoolingDeviceTableEntry Access Not accessible Index cooling DevicechassisIndex coolingDevicelndex Cooling Device Chassis Index Name coolingDevicechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Cooling Device Index Name coolingDeviceIndex Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 2 Description Defines the index of cooling devices in this chassis Syntax DellObjectRange Access Read only 200 Thermal Group Cooling Device State Capabilities Name Object ID Description Syntax Access coolingDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 700 12 1 3 Defines the capabilities of the cooling device DellStateCapabilities Read only Cooling Device State Settings Name Object ID Description Syntax Access coolingDeviceStateSettings 1 3 6 1 4 1 674 10892 1 700 12 1 4 Defines the state and settings of the cooling device DellStateSettings Read write Cooling Device Status Name Object ID Description Syntax Access coolingDeviceStatus 1 3 6 1 4 1 674 10892 1 700 12 1
365. low you to track the duration and type of events that are logged for a particular system Name Object ID Description Syntax Access cooCostEventLogTable 1 3 6 1 4 1 674 10892 1 1600 30 Defines the COO Cost Event Log Table SEQUENCE OF COO CostEventLogTableEntry Not accessible COO Cost Event Log Table Entry Name Object ID Description Syntax Access Index cooCostEventLogTableEntry 1 3 6 1 4 1 674 10892 1 1600 30 1 Defines the COO Cost Event Log Table entry cooCostEventLogTableEntry Not accessible cooCostEventLogchassisIndex cooCostEventLogIndex COO Cost Event Log Chassis Index Name Object ID Description Syntax Access cooCostEventLogchassisIndex 1 3 6 1 4 1 674 10892 1 1600 30 1 1 Defines the index one based of this chassis DellObjectRange Read only COO Cost Event Log Index Name Object ID Description Syntax Access cooCostEvent LogIndex 1 3 6 1 4 1 674 10892 1 1600 30 1 2 Defines the index one based of the cost event log DellObjectRange Read only 440 Cost of Ownership Group COO Cost Event Log State Name Object ID Description Syntax Access cooCostEventLogState 1 3 6 1 4 1 674 10892 1 1600 30 1 3 Defines the cost event log state of this system DellStateSettings Read only COO Cost Event Log Duration Name Object ID Description Syntax Access cooCostEventLogDuration 1 3 6 1 4 1 674 10892 1 1600 30 1 4 Defines the duration o
366. machine ID of this chassis DellUnsigned16BitRange Read only Chassis System Class Name Object ID Description Syntax Access chassisSystemClass 1 3 6 1 4 1 674 10892 1 300 10 1 14 Defines the chassis class of this chassis DellChassisSystemClass See Table 5 21 Read only Chassis System Name Name Object ID Description Syntax Access chassisSystemName 1 3 6 1 4 1 674 10892 1 300 10 1 15 Defines the system name of this chassis DellString Read only Chassis Information Group 75 Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 16 Description Defines the boot time of this system Syntax DellDateName Access Read only Chassis System Date Name Name chassisSystemDateName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 17 Description Defines the current time on this system Syntax DellDateName Access Read only Chassis System Location Name Name chassisSystemLocationName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 18 Description Defines the user assigned location for this chassis Syntax DellString Access Read write Chassis System Primary User Name Name chassisSystemPrimaryUserName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 19 Description Defines the user assigned primary user name for this chassis Syntax DellString Access Read write 76 l Chassis Information Group Chassis System User Phone Number Name Name chassisSystemUserPhoneNu
367. mberNam Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 20 Description Defines the user assigned phone number of the primary user of the system Syntax DellString Access Read write Chassis Connection Status Unique Name chassisConnectionStatusUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 21 Description Defines the status of the connection from the system chassis to an expansion chassis Syntax DellConnectionStatus See Table 5 3 Access Read only Chassis Fan Control Capabilities Unique Name chassisFanControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 22 Description Defines the capabilities of the fan control function in this chassis Syntax DellFanControlCapabilities See Table 5 4 Access Read only Chassis Fan Control Settings Unique Name chassisFanControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 23 Description Defines the readings and settings of the fan control hardware in the chassis Syntax DellFanControlSettings Access Read write Chassis Information Group 71 Chassis LED Control Capabilities Unique Name Object ID Description Syntax Access chassisLEDControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 300 10 1 24 Defines the capabilities of the LED control function in the chassis DellLEDControlCapabilities See Table 5 5 Read only Chassis LED Control Settings Unique Name Object ID Description Syntax Access chassisLEDControlSettingsUniq
368. me pCIDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 Description Defines the PCI Device Table entry Syntax Not accessible Access PCIDeviceTableEntry Index pClDevicechassisIndex pCIDeviceIndex PCI Device Chassis Index Name pCIDevicechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 1 Description Defines the index one based of this chassis Syntax Read only Access DellObjectRange Device Group 295 PCI Device Index Name pCIDeviceIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 2 Description Defines the index one based of the PCI device in this chassis Syntax DellObjectRange Access Read only PCI Device State Capabilities Name pCIDeviceStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 3 Description Defines the capabilities of the PCI device Syntax DellStateCapabilities Access Read only PCI Device State Settings Name pCIDeviceStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 4 Description Defines the state of the PCI device Syntax DellStateSettings Access Read write PCI Device Status Name pCIDeviceStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 5 Description Defines the status of the PCI device Syntax DellStatus Access Read only 296 Device Group PCI Device System Slot Index Reference Name Object ID Description Syntax Access pCIDeviceSystemSlotIndexReference 1 3 6 1 4 1 674 10892 1 1100 80 1 6 Defines the index number of the syst
369. me redundantMemoryUnitStatus Object ID 1 3 6 1 4 1 674 10892 1 1300 50 1 7 Description Defines the status of the redundant memory unit Syntax DellStatus Access Read only MemoryGroup__ 373 Physical Memory Card Table This table defines the name of the memory card the total number of device slots present on the memory card and the number of memory device slots in use on the memory card The following objects set up the Physical Memory Card Table Physical Memory Card Table Name Object ID Description Syntax Access physicalMemoryCardTable 1 3 6 1 4 1 674 10892 1 1300 60 Defines the Physical Memory Card Table SEQUENCE OF PhysicalMemoryCardTableEntry Not accessible Physical Memory Card Table Entry Name Object ID Description Syntax Access Index physicalMemoryCardTableEntry 1 3 6 1 4 1 674 10892 1 1300 60 1 Defines the Physical Memory Card Table Entry PhysicalMemoryCardTableEntry Not accessible physicalMemoryCardChassisIndex physicalMemoryCardIndex Physical Memory Card Chassis Index Syntax Access 374 Name Object ID Description physicalMemoryCardChassisIndex 1 3 6 1 4 1 674 10892 1 1300 60 1 1 Defines the index one based of the associated chassis DellObjectRange Read only Memory Group Physical Memory Card Index Name Object ID Description Syntax Access physicalMemoryCardIndex 1 3 6 1 4 1 674 10892 1 1300 60 1 2 Defines the index one based of the Ph
370. moryLoggingCapabilities 1 3 6 1 4 1 674 10892 1 1300 40 1 3 Defines the capabilities of the physical memory logging DellPhysicalMemoryLoggingCapabilities Read only Memory Group Physical Memory Logging Settings Name Object ID Description Syntax Access physicalMemoryLoggingSettings 1 3 6 1 4 1 674 10892 1 1300 40 1 4 Defines the settings of the physical memory logging DellPhysicalMemoryLoggingSettings Read write Physical Memory Logging Status Name Object ID Description Syntax Access physicalMemoryLoggingStatus 1 3 6 1 4 1 674 10892 1 1300 40 1 5 Defines the status of the physical memory logging DellStatus Read only Redundant Memory Unit Table This table reports the status of redundant memory within a particular system chassis The following object sets up the Redundant Memory Unit Table Name Object ID Description Syntax Access redundantMemoryUnitTable 1 3 6 1 4 1 674 10892 1 1300 50 Defines the Redundant Memory Unit Table SEQUENCE OF RedundantMemoryUnitTableEntry Not accessible Memory Group 371 Redundant Memory Unit Table Entry Name Object ID Description Syntax Access Index redundantMemoryUnitTableEntry 1 3 6 1 4 1 674 10892 1 1300 50 1 Defines the Redundant Memory Unit Table entry RedundantMemoryUnitTableEntry Not accessible redundantMemory UnitChassisIndex redundantMemoryUnitIndex Redundant Memory Unit Chassis Index Name Object ID Descripti
371. mperature Probe Reading Name Object ID Description Syntax Access temperatureProbeReading 1 3 6 1 4 1 674 10892 1 700 20 1 6 Defines the value of the temperature probe When the value for temperatureProbeType is other than temperatureProbeTypelsDiscrete the value returned for this attribute is the temperature that the probe is reading in tenths of degrees Centigrade When the value for temperatureProbeType is temperatureProbeTypelsDiscrete a value is not returned for this attribute DellSigned32BitRange Read only Thermal Group 207 Temperature Probe Type Name Object ID Description Syntax Access temperatureProbeTyp 1 3 6 1 4 1 674 10892 1 700 20 1 7 Defines the temperature probe type Dell TemperatureProbeType See Table 9 4 Read only Temperature Probe Location Name Name Object ID Description Syntax Access temperatureProbeLocationName 1 3 6 1 4 1 674 10892 1 700 20 1 8 Defines the location of the temperature probe in this chassis DellString Read only Temperature Probe Upper Nonrecoverable Threshold Name Object ID Description Syntax Access temperatureProbeUpperNonRecoverableThreshold 1 3 6 1 4 1 674 10892 1 700 20 1 9 Defines the value of the temperature probe s upper nonrecoverable threshold DellSigned32BitRange Read only Temperature Probe Upper Critical Threshold Name Object ID Description Syntax Access 208 temperatureProbeUp
372. mperature probe for example has a variable to describe its capabilities its health or status and certain indexes that you can use to locate specific temperature probes One index for the probe would be the probe s chassis number Some systems may have multiple chassis one chassis for the central processing unit and another chassis for storage A chassis within a system can also have more than one temperature probe Variables for a temperature probe include its capabilities status chassis index and index One Based Index When an index is one based counting starts at 1 One based indexing counts the first instance as 1 the second index as 2 and so on Zero Based Index When an index is zero based counting starts at 0 Zero based indexing counts the first instance as 0 the second index as 1 and so on Fields Managed object variables contain fields In this reference guide managed object variables have the following fields defined Name is the exact string by which the variable is known in the MIB MIB variables are named according to the following conventions Introduction 31 Variable names start with a lowercase letter Spaces are not allowed between words in the variable name Acronyms are in uppercase letters except when an acronym 1s the first word in the variable name e With the exception of the first letter of the variable name and acronyms all other words in the variable name start with capital
373. mperatureProbeCurValue Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 11 Description Identifies the current temperature of this probe Syntax Integer Access Read only Storage Management Group 621 Temperature Probe Roll Up Status Name temperatureProbeRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 12 Description Severity of the temperature probe state This is the combined status of the temperature probe and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Temperature Probe Component Status Name temperatureProbeComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 13 Description The status of the temperature probe itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 622 Storage Management Group Temperature Probe Nexus ID Name Object ID Description Syntax Access temperatureProbeNexusID 1 3 6 1 4 1 674 10893 1 20 130 11 1 14 Durable unique ID for this temperature probe DisplayString Read only Temperature Probe Connection Table This table describes the connection between each temperature probe on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the enclosure
374. nControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The power button has no capabilities unknownCapabilities 1 The power button capabilities are unknown enableCapable 2 The power button can be enabled online or disabled offline Table 5 17 Power Button Control Settings Variable Name De 1 1PowerButtonControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The power button has no settings capabilities unknown 1 The power button settings are unknown enabled 2 The power button state is enabled disabled 4 The power button state is disabled Table 5 18 NMI Button Control Capabilities Variable Name De 1 1NMTButtonControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The NMI button has no capabilities unknownCapabilities 1 The NMI button capabilities are unknown enableCapable 2 The NMI button can be enabled online or disabled offline 116 Chassis Information Group Table 5 19 NMI Button Control Settings Variable Name De 1 1NMIButtonControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The NMI button has no settings capabilities unknown 1 The NMI button settings are unknown enabled 2 The NMI button state is enabled disabled 4 The NMI button state is disabled
375. nControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 21 Description Defines the setup BIOS name of the NIF Wakeup on LAN Syntax DellString Access Read only BIOS Setup Control Boot Sequence Control Capabilities Unique Name bSUCbootSequenceControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 22 Description Defines the capabilities of the boot sequence Syntax DellBootSequenceControlCapabilitiesUnique SeeTable 16 5 Access Read only BIOS Setup Control Boot Sequence Control Settings Unique Name DellBootSequenceControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 23 Description Defines the state of the boot sequence Syntax DellBootSequenceControlSettingsUnique SeeTable 16 6 Access Read only BIOS Setup Control Group 389 BIOS Setup Control Boot Sequence Control Status Name bSUCbootSequenceControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 24 Description Defines the status of the boot sequence Syntax DellStatus Access Read only BIOS Setup Control Boot Sequence Control Name Name bSUCbootSequenceControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 25 Description Defines the control name of the boot sequence Syntax DellString Access Read only BIOS Setup Control Administrator Password Control Capabilities Unique Name bSUCadministratorPasswordControlCapabilities Unique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 26 Description Defines the capabilities of the administr
376. nabled notReadyCapable 4 he admin user can be in the not ready state numericPagerCapable 8 he admin user supports numeric paging alphaPagerCapable 16 he admin user supports alphanumeric paging emailCapable 32 he admin user supports e mail privilegeCapable 64 T T T T T T T T he admin user supports user privileges configuration 506 Remote Access Group Table 19 13 Remote User Admin State Settings Variable Name De 1 1RemoteUserAdminStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The admin user has no state settings unknown 1 The admin user state settings are unknown enabled 2 The admin user is enabled not Ready 4 The admin user is in the not ready state numericPagerEnabled 8 Numeric paging is enabled for the admin user alphaPagerEnabled 16 Alphanumeric paging is enabled for the admin user emailEnabled 32 E mail is enabled for the admin user Table 19 14 Remote User Admin Control Capabilities Variable Name De 1 1RemoteUserAdminControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The admin user has no control capabilities unknownCapabilities 1 The admin user control capabilities are unknown numericPagerTestCapable 2 The admin user can support sending a test numeric page alphaPagerTestCapable
377. ncludes System Resource Group Tables that track variables such as the owner ports system memory interrupts and direct memory access System Resource Group Tables The following MIB tables define objects for the System Resource Group System Resource Map Table System Resource Owner Table System Resource Input Output I O Port Table System Resource Memory Table System Resource Interrupt Table System Resource Direct Memory Access DMA Table System Resource Map Table Name systemResourceMapTable Object ID 1 3 6 1 4 1 674 10892 1 500 10 Description Defines the System Resource Map Table Syntax SEQUENCE OF SystemResourceMap TableEntry Access Not accessible System Resource Group 127 System Resource Map Table Entry Name Object ID Description Syntax Access Index System Resource Name Object ID Description Syntax Access System Resource Name Object ID Description Syntax Access System Resource Name Object ID Description Syntax Access 128 systemResourceMapTableEntry 1 3 6 1 4 1 674 10892 1 500 10 1 Defines the System Resource Map Table entry SystemResourceMap TableEntry Not accessible systemResourceMapchassisIndex systemResourceMapIndex Map Chassis Index systemResourceMapChassisIndex 1 3 6 1 4 1 674 10892 1 500 10 1 1 Defines the index one based of this chassis DellObjectRange Read only Map Index systemResourceMapIndex 1 3 6 1 4 1 674 10892 1 500 10 1 2
378. ncy functional chassis location and state was lt State gt previous redundancy state Number of devices are provided required for full redundancy lt Number gt 712 Traps Power Supply Traps Power supply traps provide status and warning information for power supplies present in a particular chassis Table 26 9 Power Supply Traps Trap ID Description Cause Power Supply Normal 1352 Power supply returned to normal Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt Power Supply type lt type of power supply gt lt Additional power supply status information gt If in configuration error state Configuration error type lt type of configuration error gt A power supply has been reconnected or replaced The sensor location chassis location previous state and additional information about the power supply event are provided Traps 713 Table 26 9 Power Supply Traps continued Trap ID Description Severity Cause 714 Power Supply Warning 1353 Power supply detected a Warning warning Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt Power Supply type lt type of power supply gt lt Additional power supply status information gt If in configuration error state Configuration error type lt type of configur
379. nd Miscellaneous Traps Table 26 2 lists Miscellaneous traps that inform you that certain alert systems are up and working Traps 699 Table 26 2 Miscellaneous Traps Trap Description Severity Cause ID System Up 1001 Server Information Server Administrator completed its Administrator initialization startup complete Thermal Shutdown 1004 Thermal shutdown Error This message is generated when a protection has system is configured for thermal been initiated shutdown due to an error event If a temperature sensor reading exceeds the error threshold for which the system is configured the operating system shuts down and the system powers off This event may also be initiated on certain systems when a fan enclosure is removed from the system for an extended period of time Automatic System Recovery 1006 Automatic System Error This message is generated when an Recovery ASR automatic system recovery action 1s action was performed due to a hung operating performed system The action performed and Action See enka the date and time of the action are was lt Action gt provided Date and time of action lt Date and time gt Host System Reset 1007 User initiated Information User requested a host system control host system control action Action requested was lt Action gt 700 Traps action to reboot power off or power cycle the system or another event such as thermal shutdown protection initiated a power of
380. nd reboot DellUnsigned32BitRange Read only LRA Global Settings Capabilities Unique Name Object ID Description Syntax Access 1RAGlobalSettingsCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1500 10 1 4 Defines the set of global capabilities that all local response agents may or may not allow to be set or reset DellLocalResponseAgentCapabilities Unique See Table 17 1 Read only LRA Global Thermal Shutdown Capabilities Unique Name Object ID Description Syntax Access 1RAGlobalThermalShutdownCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1500 10 1 5 Defines the set of thermal shutdown capabilities that are supported by the LRA DellLRAThermalShutdownCapabilitiesUnique Read only LRA Global Thermal Shutdown State Settings Unique Name Object ID Description Syntax Access 1RAGlobalThermalShutdownStateSettingsUnique 1 3 6 1 4 1 674 10892 1 1500 10 1 6 Defines the set of thermal shutdown state and settings that the local response agent supports DellLRAThermalShutdownStateSettingsUnique Read write Local Response Agent Group 421 LRA Action Table The Dell LocalResponseAgentCapabilitiesUnique variable in the global action table defines the capabilities that are allowed for a particular system The LRA Action Table that follows selects which of the system s capabilities global actions are to be enabled Name 1RAActionTableTable Object ID 1 3 6 1 4 1 674 10892 1 1500 20 Descript
381. ndant memory is enabled and in use Table 15 5 Physical Memory Configuration Redundant Capabilities Variable Name DellPhysicalMemoryConfigRedundantCapabilities Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero There are no redundant memory capabilities unknownCapabilities 1 Redundant capabilities are unknown The redundant capabilities are spareCapable 2 Spare redundant memory feature is supported mirrorCapable 4 Mirror redundant memory feature is supported spareAndMirrorCapable 6 Spare and mirror redundant memory features are supported raidCapable 8 Redundant Array of Independent disks RAID redundant memory feature is supported 380 Memory Group Table 15 6 Physical Memory Configuration Redundant Settings Variable Name DellPhysicalMemoryConfigRedundantSettings Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero There are no redundant memory settings enabled unknown 1 Redundant settings are unknown The following redundant settings are mutually exclusive spareEnabled 2 Spare redundant memory feature is enabled mirrorEnabled 4 Mirror redundant memory feature is enabled raidEnabled 8 RAID redundant memory feature is enabled Table 15 7 Physical Memory Logging Capabilities Variable Name De 11 PhysicalMemoryLoggingCapabilities Data Type Integer
382. ndex Object ID 1 3 6 1 4 1 674 10892 1 1000 30 1 2 Description Defines the index of the processor ports in this chassis Syntax DellObjectRange Access Read only Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1000 30 1 3 Description Defines the capabilities of the processor port Syntax DellStateCapabilities Access Read only Processor Port State Settings Name processorPortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 30 1 4 Description Defines the state and settings of the processor port Syntax DellStateSettings Access Read write Processor Port Status Name processorPortstatus Object ID 1 3 6 1 4 1 674 10892 1 1000 30 1 5 Description Defines the status of the processor port Syntax DellStatus Access Read only 232 Port Group Processor Port Security State Name Object ID Description Syntax Access processorPortSecurityState 1 3 6 1 4 1 674 10892 1 1000 30 1 6 Defines the security settings of the processor port DellPortSecurityState Read only Processor Port Connector Type Name Object ID Description Syntax Access processorPortConnectorType 1 3 6 1 4 1 674 10892 1 1000 30 1 7 Defines the connector type of the processor port DellProcessorPortConnectorType See Table 12 3 Read only Processor Port Name Name Object ID Description Syntax Access processorPortName 1 3 6 1 4 1 674 10892 1 1000 30 1 8 Defines name of t
383. ndex one based of this chassis Syntax DellObjectRange Access Read only Keyboard Device Index Name keyboardDeviceIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 2 Description Defines the index of the keyboard device for this chassis Syntax DellObjectRange Access Read only Keyboard Device State Capabilities Name keyboardDeviceStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 3 Description Defines the capabilities of the keyboard device Syntax DellStateCapabilities Access Read only Keyboard Device State Settings Name keyboardDeviceStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 4 Description Defines the state of the keyboard device Syntax DellStatesSettings Access Read write Device Group 263 Keyboard Device Status Name keyboardDeviceStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 5 Description Defines the status of the keyboard device Syntax DellStatus Access Read only Keyboard Port Index Reference Name keyboardPort IndexReference Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 6 Description Defines the index to the associated the keyboard port in this chassis Syntax DellStatus Access Read only Keyboard Device Type Name Name keyboardDeviceTypeName Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 7 Description Defines the name of the keyboard type Syntax DellString Access Read only Keyboard Device Layout Name Name keyboardDeviceLayoutName Object ID 1 3 6 1 4 1
384. ne based of the remote access hardware that supports this remote access dial in user Syntax DellObjectRange Access Read only Remote User Dial In Configuration User Index Name remoteUserDialInCfgUserIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 3 Description Defines the index one based of this remote access dial in user Syntax DellObjectRange Access Read only Remote User Dial In Configuration State Capabilities Name remoteUserDialInCfgStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 4 Description Defines the state capabilities of this remote access dial in user Syntax DellRemoteUserDiallnStateCapabilities See Table 19 25 Access Read only Remote Access Group 495 Remote User Dial In Configuration State Settings Name remoteUserDialInCfgStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 5 Description Defines the state settings of this remote access dial in user Syntax DellRemoteUserDiallnStateSettings See Table 19 26 Access Read write Remote User Dial In Configuration Status Name remoteUserDialInCfgStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 6 Description Defines the status of this remote access dial in user Syntax DellStatus Access Read only Remote User Dial In Configuration PPP Username Name remoteUserDialInCfgPPPUserName Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 7 Description Defines the PPP user name of this remote access dial in user Syntax DisplayString S
385. ne or more tables the second section lists these tables The third section documents the variables that comprise the group and if applicable the variables that comprise the tables The fourth section 36 Introduction contains definitions for any Server Administrator specific variables that are used in the section The following example shows the typical content of these four sections 1 BIOS Setup Control Group This section explains the purpose of the MIB group and summarizes the major features of the component groups BIOS Group Tables If there is more than one SNMP table for a group this section lists all of the tables For this BIOS group example there are eight tables listed In each section double clicking any table on the list takes you to that table e BIOS Setup Control Table SCSI Control Table e Parallel Port Control Table e Serial Port Control Table e USB Control Table IDE Control Table e Diskette Control Table e Network Interface Control Table Variables that make up each table in the group This section documents the variables for the eight tables that comprise the BIOS group BIOS Variable Values This section explains any Server Administrator specific variables and data types that are used in this section In the BIOS group example there are 17 unique Server Administrator specific variable meanings Information on each Server Administrator specific variable is presented in a formatted table
386. nel is not supported in Storage Management Syntax DisplayString Access Read only Controller C1 Port 0 ID Name controllerC1lPort0ID Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 28 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller C1 Target Name controllerClTarget Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 29 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller C1 Channel Name controllerClChannel Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 30 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only 562 Storage Management Group Controller C1 Operating System Controller Name controllerC10SController Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 31 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller Battery State C1 Name controllerClBatteryState Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 32 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller Node World Wide Name Name controllerNodewwN Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 33 Description This entry is obsolete Fibre channel is not suppor
387. nes the System Resource Memory Table entry SystemResourceMemory TableEntry Not accessible systemResourceMemorychassisIndex system ResourceMemoryIndex System Resource Memory Chassis Index Name Object ID Description Syntax Access systemResourceMemorychassisIndex 1 3 6 1 4 1 674 10892 1 500 40 1 1 Defines the index one based of this chassis DellObjectRange Read only System Resource Group 135 System Resource Memory Index Name systemResourceMemoryIndex Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 2 Description Defines the index of system resource memory in this chassis Syntax DellObjectRange Access Read only System Resource Memory State Capabilities Name systemResourceMemoryStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 3 Description Defines the capabilities of this system resource memory Syntax DellObjectRange Access Read only System Resource Memory State Settings Name systemResourceMemoryStateSettings Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 4 Description Defines the state of this system resource memory Syntax DellObjectRange Access Read write System Resource Memory Status Name systemResourceMemoryStatus Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 5 Description Defines the status of this system resource memory Syntax DellStatus Access Read only 136 System Resource Group System Resource Memory Owner Index Reference Name Object ID Description Syntax Access
388. nes the name of the CPU serial number for the system Syntax DellCostofOwnershipString Access Read write Cost of Ownership Group 435 COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 32 Description Defines the name of the operating system on this system Syntax DellCostofOwnershipString Access Read write COO Operating System Upgrade Patch Level Name Name cooOperatingSystemUpgradePatchLevelNam Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 33 Description Defines the name of the operating system patch level for this system Syntax DellCostofOwnershipString Access Read write COO Operating System Upgrade Date Name cooOperatingSystemUpgradeDate Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 34 Description Defines the upgrade file date for this operating system Syntax DellCostofOwnershipString Access Read write COO Depreciation Duration Name cooDepreciationDuration Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 35 Description Defines the length of depreciation for this system Syntax DellUnsigned32BitRange Access Read write 436 Cost of Ownership Group COO Depreciation Duration Type Name Object ID Description Syntax Access cooDepreciationDurationType 1 3 6 1 4 1 674 10892 1 1600 10 1 36 Defines the unit of time for the depreciation of this system DellCooMonthYearDuration Type Read write COO Depreciation Percentage Name
389. ng Read only DRsProductChassisAssetTag Name Object ID Description Syntax Access DRsProductChassisAssetTag 1 3 6 1 4 1 674 10892 2 1 1 8 Defines the Asset Tag of the chassis DellString Read only DRsProductChassisLocation Name Object ID Description Syntax Access DRsProductChassisLocation 1 3 6 1 4 1 674 10892 2 1 1 9 Defines the location of the chassis DellString Read only DRsProductChassisName Name Object ID Description Syntax Access DrsProductChassisName 1 3 6 1 4 1 674 10892 2 1 1 10 Defines the name of the chassis DellString Read only Dell RAC Out of Band Group 669 DRsSystemServiceTag Name DRsSystemServiceTag Object ID 1 3 6 1 4 1 674 10892 2 1 1 11 Description Defines the service tag of a system Syntax DellString Access Read only DRsProductSystemAssetTag Name DRsProductSystemAssetTag Object ID 1 3 6 1 4 1 674 10892 2 1 1 12 Description Defines the asset tag of a system Syntax DellString Access Read only DRsProductSystemSlot Name DRsProductSystemSlot Object ID 1 3 6 1 4 1 674 10892 2 1 1 13 Description Defines the slot number of a CMC Syntax DellString Access Read only DRsProductType Name DRsProductType Object ID 1 3 6 1 4 1 674 10892 2 1 1 14 Description Defines type of a remote access card Syntax DellRacType Access Read only 670 Dell RAC Out of Band Group DRsFirmwareVersion Name Object ID Description Syntax Access DRsFirmware
390. ng system on the host manualOperatingSystemShutdownThe nReboot 9 The operator can shut down the operating system on the host then reboot Chassis Information Group 113 Table 5 12 Host Control Settings continued Variable Name De 1HostControlSettings NOTE An operator can manually cause these actions using SNMP Data Type Integer Possible Data Values Meaning of Data Value manualOperatingSystemShutdowntThe The operator can shut down the nPowerOFF 10 operating system on the host then power off machine manualOperatingSystemShutdownthe The operator can shut down the nPowerCycle 12 operating system on the host then power cycle machine Table 5 13 Watchdog Control Capabilities Variable Name De 1 1Wat chDogControlCapabilities NOTE When the system determines that the operating system is not responding it will automatically perform the selected action without operator intervention Data Type Integer Possible Data Values Meaning of Data Value automat icRebootCapable 1 Watchdog controls can be set to reboot capable host automat icPowerCycleCapable 2 Watchdog controls can be set to power cycleable capable host automaticNotificationCapable 4 Watchdog controls can be set to notify capable host automaticWatchDogTimerCapable 8 Watchdog controls can be set to function automatically automat icPowerOffCapable 16 Watchdog controls can be set to
391. ning action definition 474 memory device failure action definition 1006 automatic system recovery ASR action definition 1353 power supply warning action definition 1553 log near full action definition 1554 log full action definition 1603 processor warning action definition 1604 processor failure action definition 1703 battery warning action definition 1704 battery failure action definition Syntax DellUnsigned16BitRange Access Read only Local Response Agent Group 423 LRA Action Table User Application Name Name Object ID Description Syntax Access 1RAActionTableUserApplicationName 1 3 6 1 4 1 674 10892 1 1500 20 1 3 When the execute application value is set provides the following user assignable LRA information e Name of the user application executable path e File name to execute DisplayString SIZE 0 256 Read write LRA Action Table Settings Unique Name Object ID Description Syntax Access 1RAActionTableSettingsUnique 1 3 6 1 4 1 674 10892 1 1500 20 1 4 Defines the LRA settings DellLocalResponseAgentSettingsUnique See Table 17 3 Read write Local Response Agent Variable Values This section includes definitions for server administrator specific variable values used in this section Table 17 1 LRA Capabilities Definitions Variable Name De 1 1 LocalResponseAgentCapabilitiesUnique Data Type Integer Possible Data Values Me
392. nnelEntry Access Not accessible Channel Entry Name channelEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 Description Defines the channel table entry Syntax ChannelEntry Access Not accessible Index channelNumber Channel Number Name channelNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 1 Description Identifies the instance number of the channel entry Syntax Integer Access Read only 570 Storage Management Group Channel Name Name Object ID Description Syntax Access Channel State Name Object ID Description Syntax Access channelName 1 3 6 1 4 1 674 10893 1 20 130 2 1 2 Identifies the name of the channel as represented in Storage Management The name will include the word channel and the instance For example Channel 1 DisplayString Read only channelState 1 3 6 1 4 1 674 10893 1 20 130 2 1 3 Identifies the current state of this channel Possible states 0 Unknown 1 Ready The I O has resumed 2 Failed 3 Online 4 Offline The I O has paused 6 Degraded Integer Read only Channel Severity Name Object ID Description Syntax Access channelSeverity 1 3 6 1 4 1 674 10893 1 20 130 2 1 4 This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Integer Read only Storage Management Group _ 571 Channel Termination Name channelTermination Object ID 1 3 6 1 4 1 674 10
393. norVersionNumber and mIBMaintenanceVersionNumber attributes are scalar objects meaning that they are not related to other MIB objects and are thus not placed in a table MIB Major Version Number Name mIBMajorVersionNumber Object ID 1 3 6 1 4 1 674 10892 1 1 1 0 Description Defines the major version number of the version of this MIB supported by the systems management software For example if the MIB version is 1 2 3 the major version number is 1 A major version number change indicates a major change in object functionality Syntax DellUnsigned8BitRange Access Read only Instrumentation MIB Version Group 43 MIB Minor Version Number Name mIBMinorVersionNumber Object ID 1 3 6 1 4 1 674 10892 1 1 2 0 Description Defines the minor version number of the version of this MIB supported by the systems management software For example if the MIB version is 1 2 3 the minor version number is 2 A minor revision provides additional support for new objects as well as problem fixes Syntax DellUnsigned8BitRange Access Read only MIB Maintenance Version Number Name mIBMaintenanceVersionNumber Object ID 1 3 6 1 4 1 674 10892 1 1 3 0 Description Defines the maintenance version number for the version of this MIB supported by the systems management software For example if the MIB version is 1 2 3 the maintenance version number is 3 Syntax DellUnsigned8BitRange Access Read only 44 Instrumentation MIB Version Group
394. nownCapabilities The SNMP trap destination control capabilities are 1 unknown trapTestCapable 2 ASNMP trap test can be performed for the SNMP trap destination Table 19 21 Remote SNMP Trap Control Settings Variable Name De 1 1RemoteSNMPTrapControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The SNMP trap destination has no control settings unknown 1 The SNMP trap destination control settings are unknown trapTestCapable 2 ASNMP trap test will be performed for the SNMP trap destination Table 19 22 Remote Dial Up State Capabilities Variable Name De 1 1RemoteDialUpStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The dial up functionality has no state capabilities unknownCapabilities 1 The dial up functionality state capabilities are unknown 510 enableCapable 2 The dial up functionality can be disabled or enabled Remote Access Group Table 19 22 Remote Dial Up State Capabilities continued Variable Name De 1 1RemoteDialUpStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value notReadyCapable 4 The dial up functionality can be in the not ready state dial InCapable 8 The dial up functionality can support the dial in feature dial OutCapable 16 The dial up functionality can support the dial out fea
395. ns and Corrective Actions section The MIB is located in sm mibs dcstorag mib a subdirectory of the Storage Management installation directory NOTE Storage Management supports trap forwarding on both 32 bit and 64 bit operating systems SNMP Trap Variables The Storage Management SNMP traps use a set of variables that are included with every trap These variables are the following e messageIDEvent e descriptionEvent e locationEvent objectNameEvent objectOIDEvent objectNexusEvent e currentStatusEvent e previousStatusEvent 740 Storage Management Alert Reference Viewing SNMP Traps SNMP traps that are generated by Storage Management can be viewed in any standard SNMP compatible enterprise management console These traps are defined in the Storage Management MIB These traps correspond to the alerts documented in the Alert Descriptions and Corrective Actions section For more information on the MIB and its structure as well as a change history of the SNMP traps see the Introduction section For more information on configuring SNMP see SNMP Support for Storage Management Alerts Alert Descriptions and Corrective Actions The alerts generated by the redundant array of independent disks RAID or Small Computer System Interface SCSI controllers and supported by Storage Management are displayed in the Server Administrator Alert subtab or through Windows Event Viewer These alerts can also be forwarded
396. nsitioned back to a normal state The sensor location chassis location previous state and battery sensor status are provided Battery Warning 1703 Battery sensor detected Warning a warning value Sensor Location lt Location in chassis gt Chassis Location of chassis gt lt Name Previous state was lt State gt Battery sensor status lt status gt A battery sensor in the specified system detected that a battery is in a predictive failure state The sensor location chassis location previous state and battery sensor status are provided Traps 723 Table 26 16 Battery Traps continued Trap ID Description Severity Cause Battery Failure 1704 Battery sensor detected Critical a failure value Sensor Location lt Location in chassis gt Chassis Location lt Name of chassis gt Previous state was lt State gt Battery sensor status lt status gt A battery sensor in the specified system detected that a battery has failed The sensor location chassis location previous state and battery sensor status are provided SD Card Device Traps On systems where the BMC reports the status of SD card devices the SD card device traps provide status and error information Table 26 17 SD Card Device Traps Trap ID Description Severity Cause SD Card Device Failure 1754 SD card device detected Critical An SD card device sensor a failure Sensor Loca
397. nstance number in the appropriate MIB table for that object where all of the object properties can be found Array Disk Channel Connection Table describes the connections between SCSI array disks their channel and their associated controller For each object in the table its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found Fan Table describes available properties for each fan on the managed system Fan Connection Table describes the connection between each fan on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table Power Supply Table describes available properties for each power supply on the managed system Power Supply Connection Table describes the connection between each power supply on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table Storage Management Group e Temperature Probe Table describes available properties for each temperature probe on the managed system e Temperature Probe Connection Table describes the connection between each temperature probe on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table e EMM Table describes available properties f
398. ntax DellUnsigned32BitRange Access Read only Memory Device Speed Name memoryDeviceSpeed Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 15 Description Defines the speed in nanoseconds of the memory device A zero 0 indicates that the speed is unknown Syntax DellUnsigned32BitRange Access Read only Device Group 285 Memory Device Total Bus Width Object ID Description Syntax Access memoryDeviceTotalBusWidth 1 3 6 1 4 1 674 10892 1 1100 50 1 16 Defines the total number of bits including ECC used by the memory device DellUnsigned32BitRange Read only Memory Device Total Data Bus Width Name Object ID Description Syntax Access memoryDeviceTotalDataBusWidth 1 3 6 1 4 1 674 10892 1 1100 50 1 17 Defines the total number of data bits used by the memory device DellUnsigned32BitRange Read only Memory Device Correctable Memory Event Count K NOTE Memory Device Failure Modes has now replaced this attribute Memory Device Correctable Memory Event Count should no longer be used If you use the Memory Device Correctable Memory Event Count attribute the value returned is always zero and using the attribute will have no effect Name Object ID Description Syntax Access 286 memoryDeviceSingleBitErrorCount 1 3 6 1 4 1 674 10892 1 1100 50 1 18 Defines the total number of Correctable Memory Events detected by the memory device DellSigned32BitRange Read only Devi
399. ntenance information DellStateSettings Read only COO Maintenance Start Date Name Name Object ID Description Syntax Access cooMaintenanceStartDateName 1 3 6 1 4 1 674 10892 1 1600 80 1 4 Defines the start date for maintenance on this system DellDateName Read write Cost of Ownership Group 451 COO Maintenance End Date Name Name cooMaintenanceEndDateNam Object ID 1 3 6 1 4 1 674 10892 1 1600 80 1 5 Description Defines the end date for maintenance on this system Syntax DellDateName Access Read write COO Maintenance Provider Name Name cooMaintenanceProviderNam Object ID 1 3 6 1 4 1 674 10892 1 1600 80 1 6 Description Defines the maintenance provider s name Syntax DellStateSettings Access Read write COO Maintenance Restrictions Name Name cooMaintenanceRestrictionsName Object ID 1 3 6 1 4 1 674 10892 1 1600 80 1 7 Description Defines the maintenance agreement restrictions Syntax DellCostofOwnershipString Access Read write COO Repair Table Name cooRepairTable Object ID 1 3 6 1 4 1 674 10892 1 1600 90 Description Defines the COO Repair Table Syntax SEQUENCE OF CooRepairTableEntry Access Not accessible 452 Cost of Ownership Group COO Repair Table Entry Name Object ID Description Syntax Access Index cooRepairTableEntry 1 3 6 1 4 1 674 10892 1 1600 90 1 Defines the COO Repair Table entry CooRepairTableEntry Not accessible cooRepairchassisIndex cooRepairIndex
400. nting device DellStatus Read only Pointing Port Index Reference Name Object ID Description Syntax Access pointingPort IndexReference 1 3 6 1 4 1 674 10892 1 1100 10 1 6 Defines the index to the pointing port in this chassis DellObjectRange Read only Device Group 261 Pointing Device Type Name pointingDeviceType Object ID 1 3 6 1 4 1 674 10892 1 1100 10 1 7 Description Defines the type of the pointing device Syntax DellPointingDeviceType See Table 13 1 Access Read only Pointing Device Number of Buttons Name pointingDeviceNumberofButtons Object ID 1 3 6 1 4 1 674 10892 1 1100 10 1 8 Description Defines the number of buttons on the pointing device Syntax DellUnsigned8BitRange Access Read only Keyboard Device Table Name keyboardDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 20 Description Defines the Keyboard Device Table This table references the Keyboard Port Index See Section 12 Syntax SEQUENCE OF KeyboardDeviceTableEntry Access Not accessible Keyboard Device Table Entry Name keyboardDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 Description Defines the Keyboard Device Table entry Syntax KeyboardDeviceTableEntry Access Not accessible Index keyboardDevicechassisIndex keyboardDeviceIndex 262 Device Group Keyboard Device Chassis Index Name keyboardDevicechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 1 Description Defines the i
401. ntry Name temperatureProbeTableEntry Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 Description Defines the Temperature Probe Table entry Syntax TemperatureProbeTableEntry Access Not accessible Index temperatureProbechassisIndex temperatureProbelndex Temperature Probe Chassis Index Name temperatureProbechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Temperature Probe Index Name temperatureProbeIndex Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 2 Description Defines the index of temperature probes in this chassis Syntax DellObjectRange Access Read only Temperature Probe State Capabilities Name temperatureProbeStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 3 Description Defines the capabilities of the temperature probe Syntax DellStateCapabilities Access Read only 206 Thermal Group Temperature Probe State Settings Name Object ID Description Syntax Access temperatureProbeStateSettings 1 3 6 1 4 1 674 10892 1 700 20 1 4 Defines the state and settings of the temperature probe DellStateSettings Read write Temperature Probe Status Name Object ID Description Syntax Access temperatureProbeStatus 1 3 6 1 4 1 674 10892 1 700 20 1 5 Defines the status of the temperature probe in tenths of degrees Celsius DellStatusProbe Read only Te
402. od 1 The voltage probe discrete reading is good voltagelIsBad 2 The voltage probe discrete reading is bad Table 8 8 Amperage Probe Definitions Variable Name De 1 1AmperageTyp Data Type Integer Possible Data Values Meaning of Data Value amperageProbeTyp IsOther 1 The amperage probe type is not one of the following amperageProbeTyp IsUnknown 2 The amperage probe type is unknown not known or not monitored amperageProbeTyp TslPoint5Volt 3 The amperage probe type is a 1 5 ampere A probe amperageProbeTyp Is3Point3volt 4 The amperage probe type is a 3 3 A probe amperageProbeTyp Is5Volt 5 The amperage probe type is a 5 A probe amperageProbeTyp IsMinus5Volt 6 The amperage probe type is a 5 A probe amperageProbeTyp Is12Volt 7 The amperage probe type is a 12 A probe amperageProbeTyp IsMinus12Volt 8 The amperage probe type is a 12 A probe amperageProbeTypelIsi10 9 The amperage probe type is an 1 O amperage probe amperageProbeTypelsCore 10 The amperage probe type is a core amperage probe Power Group 189 Table 8 8 Amperage Probe Definitions continued Variable Name De 1 1AmperageTyp Data Type Integer Possible Data Values Meaning of Data Value amperageP robeTypelIsFLEA 11 The amperage probe type is a FLEA st
403. oltage DRAC III Critical voltage probe reading probe has exceeded detected a critical failure threshold or critical value 1015 alertDrscSEL The RAC Major Error RAC All Warning has detected a detected a new system new event event log with in the warning System severity Event Log detailed log with info is in Severity drsAlert Warning Message varbind Traps 729 Table 26 19 Enterprise specific Traps continued 730 Trap Name Description Severity Category Cause Supported ID by RAC Platform 1016 alertDrscSEL The RAC Critical Error RAC All Critical has detected a detecteda new system new event event log with in the critical System severity Event Log detailed log with info is in Severity drsAlert Critical Message varbind 1017 alertDrscSEL The RAC Major Status RAC All 80 system detected percentFull event log system event is 80 log is 80 full full 1018 alertDrscSEL The RAC Major Status RAC All 90 system detected percentFull event log system event is 90 log is 90 full full 1019 alertDrscSEL The RAC Major Status RAC All 100 system detected percentFull event log system event is 100 log is 100 full full Traps Table 26 19 Enterprise specific Traps continued Trap Name Description Severity Category Cause Supported ID by RAC Platform 1020 alertDrscSEL The RAC Information Error RAC All Normal has detected a detecteda new system new event event log with in the normal Sy
404. oltageProbeType is voltageProbeTypelsDiscrete a value is not returned for this attribute Syntax DellSigned32BitRange Access Read only Voltage Probe Type Name voltageProbeType Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 7 Description Defines the type of the voltage probe Syntax DellVoltageType Access Read only Voltage Probe Location Name Name voltageProbeLocationName Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 8 Description Defines the location of the voltage probe in this chassis Syntax DellString Access Read only Voltage Probe Upper Nonrecoverable Threshold Name voltageProbeUpperNonRecoverableThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 9 Description Defines the value of the voltage probe s upper nonrecoverable threshold Syntax DellSigned32BitRange 158 Power Group Name voltageProbeUpperNonRecoverableThreshold Access Read only Voltage Probe Upper Critical Threshold Name voltageProbeUpperCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 10 Description Defines the value of the voltage probe s upper critical threshold Syntax DellSigned32BitRange Access Read only Voltage Probe Upper Noncritical Threshold Name voltageProbeUpperNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 11 Description Defines the user assigned value of the voltage probe s upper noncritical threshold Syntax DellSigned32BitRange Access Read write Voltage Probe Lower Noncritical
405. on Syntax Access redundantMemoryUnitChassisIndex 1 3 6 1 4 1 674 10892 1 1300 50 1 1 Defines the index one based of the chassis associated with the redundant memory unit DellObjectRange Read only Redundant Memory Unit Index Name Object ID Description Syntax Access redundantMemoryUnit Index 1 3 6 1 4 1 674 10892 1 1300 50 1 2 Defines the index one based of the redundant memory unit DellObjectRange Read only Redundant Memory Unit State Capabilities Name Object ID Description Syntax Access 372 redundantMemoryUnitStateCapabilities 1 3 6 1 4 1 674 10892 1 1300 50 1 3 Defines the state capabilities of the redundant memory unit DellStateCapabilities Read only Memory Group Redundant Memory Unit State Settings Name redundantMemoryUnitStatesettings Object ID 1 3 6 1 4 1 674 10892 1 1300 50 1 4 Description Defines the state settings of the redundant memory unit Syntax DellStateSettings Access Read write Redundant Memory Unit Redundancy Status Name redundantMemoryUnitRedundancyStatus Object ID 1 3 6 1 4 1 674 10892 1 1300 50 1 5 Description Defines the redundancy status of the redundant memory unit Syntax DellStatusRedundancy Access Read only Redundant Memory Unit Name Name redundantMemoryUnitName Object ID 1 3 6 1 4 1 674 10892 1 1300 50 1 6 Description Defines the name of the redundant memory unit Syntax DellString Access Read only Redundant Memory Unit Status Na
406. on of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Controller Nexus ID Name Object ID Description Syntax Access controllerNexusID 1 3 6 1 4 1 674 10893 1 20 130 1 1 39 Durable unique ID for this controller DisplayString Read only Controller Alarm State Name Object ID Description Syntax Access controllerAlarmState 1 3 6 1 4 1 674 10893 1 20 130 1 1 40 Indicates state or setting for the controller s alarm Possible values 1 Enabled 2 Disabled 3 Not Applicable Integer Read only Storage Management Group 565 Controller Driver Version Name controllerDriverVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 41 Description Indicates currently installed driver version of the controller Syntax DisplayString Access Read only Controller PCI Slot Name controllerPCISlot Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 42 Description Indicates the PCI slot number or embedded number for controllers on the motherboard Syntax DisplayString Access Read only Controller Cluster Mode Name controllerClusterMode Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 43 Description Identifies if the controller is in cluster mode Possible values 1 Enabled 2 Disabled 3 Active enabled and active 99 Not Applicable Syntax Integer Access Read only 566 Storage Management Group
407. on this system Syntax DellRemoteFlashBIOSStateStatus Access Read only Remote Flash BIOS Last BIOS Date Name Name remoteF lashBIlOSLastBIOSDateName Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 6 Description Defines the date of the last BIOS update Syntax DellDateName Access Read only Remote Flash BIOS Completion Code Name remoteF lashBlOSCompletionCode Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 7 Description Defines the completion code of the last BIOS update Syntax DellRemoteFlashBIOSCompletionCode See Table 11 3 Access Read only Remote Flash BIOS Minimum Contiguous Memory Name remoteFlashBIOSMinimumContiguousMemory Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 8 Description Defines the minimum size of contiguous memory required for remote BIOS update in kilobytes Syntax DellUnsigned32BitRange Access Read only Remote Flash BIOS Group 221 Remote Flash BIOS Variable Values This section includes definitions for server administrator specific variable values used in this section Table 11 1 Remote Flash BIOS State Capabilities Unique Variable Name De 1 1RemoteFlashBlOSStateCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The remote flash BIOS s capabilities are unknown enableCapable 2 The remote flash BIOS can be disabled offline a binary 0 value or enabled online a binary 1 value notReadyCapable 4 The remote flash BIOS can be
408. on of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 63 Access Read only Remote Access Local Area Network LAN Capabilities Name remoteAccessLANCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 14 Description Defines the LAN capabilities of the remote access hardware Syntax DellRemoteAccessLANCapabilities See Table 19 6 Access Read only Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 15 Description Defines the LAN settings of the remote access hardware Syntax DellRemoteAccessLANSettings See Table 19 7 Access Read write Remote Access Network Interface Controller NIC Static IP Address Name remoteAccessNICStaticIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 25 Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read write 464 Remote Access Group Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read write Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 27 Description Defines the IP address for
409. operating system shutdown capable host manualRebootWithOSShutdow The operator can reboot with operating nCapable 16 system shutdown 112 Chassis Information Group Table 5 11 Host Control Capabilities continued Variable Name Del 1HostControlCapabilities NOTE An operator can manually enable these actions using SNMP Data Type Integer Possible Data Values Meaning of Data Value manualRebootWithoutOSShut downCapable 32 The operator can reboot without operating system shutdown manualPowerOffWithOSShutd ownCapable 64 The operator can power off with operating system shutdown manualPowerOffWithoutOSSh utdownCapable 128 The operator can power off without operating system shutdown manualPowerCycleWithOSShu tdownCapable 256 The operator can power cycle with operating system shutdown manualPowerCycleWithoutOSs ShutdownCapable 512 The operator can power cycle without operating system shutdown Table 5 12 Host Control Settings Variable Name Del 1HostControlSettings NOTE An operator can manually cause these actions using SNMP Data Type Integer Possible Data Values Meaning of Data Value manualReboot 1 The operator can reboot the host manualPowerOFF 2 The operator can power off the host manualPowerCycle 4 Power cycle the host manualOperatingSystemShutdown 8 The operator can shut down the operati
410. or on the backplane board system board or drive carrier in the specified system exceeded its failure threshold The sensor location chassis location previous state and temperature sensor value are provided Temperature Probe Nonrecoverable Temperature sensor detected a non recoverable valu Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Temperature sensor value in degrees Celsius lt Reading gt If sensor type is discrete Discrete temperature stat lt State gt Error A temperature sensor on the backplane board system board or drive carrier in the specified system detected an error from which it cannot recover The sensor location chassis location previous state and temperature sensor value are provided Traps 703 Cooling Device Traps Cooling device traps monitor how well a fan is functioning Table 26 4 Cooling Device Traps Trap ID Description Severity Cause Cooling Device Normal 1102 Fan sensor returned to a normal value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt Fan sensor value lt Reading gt Information A fan sensor reading on the specified system returned to a valid range after crossing a warning threshold The sensor location chassis loc
411. or type is a MicroDIN connectorPortTypelsPS2 5 The keyboard port connector type is PS 2 connectorPortTypelsInfrared 6 The keyboard port connector type is infrared connectorPortTypelIsHPHIL 7 The keyboard port connector type is HP HIL connectorPortTypelIsDB9 8 The keyboard port connector type is DB 9 connectorPortTypelsAccessBusUSB 9 The keyboard port connector type is bus USB connectorPortTypelsPC98 10 The keyboard port connector type is PC 98 254 Port Group Table 12 3 Processor Port Connector Types Variable Name De 1 1ProcessorPortConnectorType Data Type Integer Possible Data Values Meaning of Data Value connec COL Por tTypelsOther 1 The processor port connector type is not one of the following connec COL Por t TypeIsUnknown 2 The processor port connector type is unknown connec COL Por tTypeIsDaughterdBoard 3 The processor port connector type is a daughter board connec COL Por tTypelsZ1IFSocket 4 The processor port connector type is a zero insertion force ZIF socket connec COL Por tTypelIsAPiggyBackBoard 5 The processor port connector type is a replacement piggyback board connec COL Por t TypelIsNone 6 There is no processor port connector processor is soldered in place connec COL Por tTypeIsLIFSocket 7 The processor port connector type is a low insertion fo
412. or defined OIDs consist of 1 3 6 1 4 1 674 followed by additional component values SNMP Security SNMP version 1 has a very limited security mechanism SNMP agents support the use of a community string which is configured at each SNMP agent and is passed as a part of all SNMP request messages There is no verification that the requester is actually a member of the specified community Because most system and network management data is not confidential this limited security is acceptable for Get types of requests On the other hand this security is not acceptable for Set types of operations where an SNMP request could power off a system reconfigure a redundant array of independent disks RAID card and so on Some vendors have chosen not to support SNMP Set operations for this reason Server Administrator is able to support SNMP Set operations because its SNMP agents implement a hash digest mechanism to prevent unauthorized SNMP Set operations One limitation of this practice is that only server administrator developed SNMP management applications have the capability to support the hash digest mechanism K NOTE The default SNMP agent configuration usually includes a SNMP community name such as public For security reasons change the SNMP community names from their default values For information about changing SNMP community names see the Dell OpenManage Server Administrator User s Guide available on the Dell Support website at suppo
413. or each Enclosure Management Module EMM on the managed system EMM Connection Table describes the connection between each EMM on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table e Battery Table describes available properties for each controller battery on the managed system e Battery Connection Table describes the connection between each battery on the managed system and its controller Each controller number in the table corresponds to that controller instance in the Controller Table Controller Table This table describes available properties for each controller on the managed system The following object sets up the Controller Table Name controllerTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 Description Defines the controller table which is a table of managed Redundant Array of Independent disks RAID controllers The number of entries is related to the number of RAID controllers discovered in the system Syntax SEQUENCE OF ControllerEntry Access Not accessible Storage Management Group __ 553 Controller Entry Name controllerEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 Description Defines the controller table entry which is an entry in the table of RAID controllers A row in this table cannot be created or deleted by SNMP operations on columns of the table Syntax ControllerEntry Access Not acces
414. orPortTypelIsUnknown 2 The pointing port connector type is unknown connectorPortTypelIsSerial 3 The pointing port connector type is serial connectorPortTypelIsPS2 4 The pointing port connector type is a Personal System 2 PS 2 connectorPortTypelsInfrared 5 The pointing port connector type is infrared connectorPortTypelIsHPHIL 6 The pointing port connector type is HP HIL connectorPortTypelsBusMouse 7 The pointing port connector type is a bus mouse connectorPortTypelIsADB 8 The pointing port connector type is ADB connectorPortTypelIsDB9 9 The pointing port connector type is nine pin DB 9 connectorPortTypelIsMicroDIN 10 The pointing port connector type is micro Deutsche Industrie Norm DIN connectorPortTypelsAccessBusUSB The pointing port connector type is 11 Access Bus USB connectorPortTypelIsPC98 12 The port connector type is a PC 98 PortGroup 253 Table 12 2 Keyboard Port Connector Types Variable Name De 1 1KeyboardPortConnectorType Data Type Integer Possible Data Values Meaning of Data Value connectorPortTypelsOther 1 The keyboard port connector type is not one of the following connectorPortTypelIsUnknown 2 The keyboard port connector type is unknown connectorPortTypeIsMiniDIN 3 The keyboard port connector type is a mini DIN connectorPortTypeIsMicroDIN 4 The keyboard port connect
415. ormation on RAC legacy alerting Table 1 7 describes each Dell RAC Out of Band group and lists the MIB group number assigned to the MIB group See the relevant section for more information about the MIB objects defined in a MIB group 28 Introduction Table 1 7 Dell RAC Out of Band MIB Section Topics MIB Group Number 25 The Dell RAC Out of Band MIB consists of information for 2 the following groups e Product Information e Chassis Status e Chassis Power e CMC Power Information e CMC PSU Information e Chassis Alerts e Legacy Alerting How This Guide Defines Technical Terms The following table provides information about where to find definitions for technical terms in this reference guide Table 1 8 Where to Find Definitions for Technical Terms Type of Definition See Basic SNMP vocabulary Introduction MIB group specific variable values Sections 3 5 7 8 9 and 11 MIB group specific MIB variables contain links to the through 18 tables that define these values in the last section of the section in which these variables are used Systems management terms acronyms and Glossary available on the Dell commonly managed components referred to in this Support website at reference guide support dell com manuals Server Administrator standard data types that specify Appendix A Standard Data variable values in this reference guide Type Definitions Introduction 29 SNMP Basic Term
416. oryUnitStatusRedundancy Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 39 Description Defines the overall redundancy status for redundant memory Syntax DellStatusRedundancy Access Read only System State Redundant Memory Unit Status Details Name systemStateRedundantMemoryUnitStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 40 Description Defines the status of all redundant memory units in this chassis The results are returned as a binary octet string each byte of the octet string represents the status of the specific object The first byte returned represents the status of the first object and so on The bytes have the same definition type as DellStatusRedundancy Syntax OCTET STRING SIZE 1 128 Access Read only 64 System State Group System State Event Log Status Name systemStateEventLogStatus Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 41 Description Defines the overall status of this chassis ESM event log Syntax DellStatus Access Read only System State Power Unit Status Combined Name systemStatePowerUnitStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 42 Description Defines the combined status of all power units of this chassis Syntax DellStatus Access Read only System State Power Unit Status List Name systemStatePowerUnitStatusList Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 43 Description Lists the status of each power unit of this chassis The results are returned as a binary octet s
417. ot supported 340 Device Group Table 13 22 Network Device TOE Capability Flags Variable Name De 1 1NetworkDeviceTOECapabilityFlags Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value unknown 1 Querying for TOE capability is supported but query returned an error available 2 Device has TOE capability notAvailable 4 Device does not have TOE capability cannotBeDetermined 8 Querying for TOE capability is supported but an error prevented querying driverNotResponding 16 Querying for TOE capability is supported but driver did not respond to query Table 13 23 Network Device RDMA Capability Flags Variable Name De 1 1NetworkDeviceRDMACapabilityFlags Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 Querying for RDMA capability is not supported unknown 1 Querying for RDMA capability is supported but query returned an error available 2 Device has RDMA capability notAvailable 4 Device does not have RDMA capability cannotBeDetermined 8 Querying for RDMA capability is supported but an error prevented querying driverNotResponding 16 Querying for RDMA capability is supported but driver did not respond to query Device G
418. otFromHardDriveFirst 4 Setup BIOS is set to boot by IDE hard drive first bootFromDeviceList 8 Setup BIOS is set to boot by a device list bootFromCDROMFirst 16 Setup BIOS is set to boot by CD first BIOS Setup Control Group 411 Table 16 7 BIOS Password Control Capabilities Variable Name De11BTOSPasswordControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value passwordControlCapabilitiesUn known 1 BIOS password capabilities are unknown passwordControlEnableCapable 2 Setup BIOS is capable of enabling password changes passwordControlJumperDisable Capable 4 Setup BIOS is capable of determining if password control can be jumper disabled passwordControlEnableANDJumper DisableCapable 6 Setup BIOS is capable of enabling password changes and of determining if password control can be jumper disabled Table 16 8 BIOS Password Control Settings Unique Variable Name De 1 1BTOSPasswordControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown 1 Setup BIOS password state is unknown passwordControlEnabled 2 Setup BIOS has password changes enabled passwordControlJumperDisabled 4 Setup BIOS has determined that password control has been disabled by a jumper 412 BIOS Setup Control Group Table 16 9 BIOS Password Control Setting
419. oteAccessTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 Description Defines the Remote Access Table entry Syntax RemoteAccessTableEntry Access Not accessible Index remoteAccessChassisIndex remoteAccessAdapterIndex Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellObjectRange Access Read only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 2 Description Defines the index one based of the remote access hardware Syntax DellObjectRange Access Read only 468 Remote Access Group Remote Access Type Name remoteAccessTyp Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 3 Description Defines the type of remote access hardware Syntax DellRemoteAccess Type See Table 19 1 Access Read only Remote Access State Capabilities Name remoteAccessStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 4 Description Defines the state capabilities of the remote access hardware Syntax DellStateCapabilities Access Read only Remote Access State Settings Name remoteAccessStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 5 Description Defines the state setting of the remote access hardware Syntax DellStateSettings Access Read write Remote Access Status Name remoteAccessStat
420. ource OPortchassisIndex systemResourcelOPortIndex 132 System Resource Group System Resource 1 0 Port Chassis Index Name Object ID Description Syntax Access systemResourcelOPortchassisIndex 1 3 6 1 4 1 674 10892 1 500 30 1 1 Defines the index one based of this chassis DellObjectRange Read only System Resource 1 0 Port Index Name Object ID Description Syntax Access systemResourcelOPortIndex 1 3 6 1 4 1 674 10892 1 500 30 1 2 Defines the index one based of the system resource I O ports in this chassis DellObjectRange Read only System Resource I 0 Port State Capabilities Name Object ID Description Syntax Access systemResourcelOPortStateCapabilities 1 3 6 1 4 1 674 10892 1 500 30 1 3 Defines the capabilities of the system resource I O port DellStateCapabilities Read only System Resource 1 0 Port State Settings Name Object ID Description Syntax Access systemResourcelOPortStateSettings 1 3 6 1 4 1 674 10892 1 500 30 1 4 Defines the state and allows the setting of the system resource T O port DellStateSettings Read write System Resource Group 133 System Resource 1 0 Port Status Name systemResourcelOPortStatus Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 5 Description Defines the status of the system resource I O port Syntax DellStateSettings Access Read only System Resource I O Port Owner Index Reference Name systemResourcelOPortOwnerIndexRef
421. out values recorded by probes or sensors Probes and sensors monitor critical components for values such as amperage voltage and temperature When an event occurs on your system the Server Administrator sends information about one of the following event types to the system management console 698 Information Informational An event that describes the successful operation of a unit such as a power supply turning on or a sensor reading returning to normal Warning An event that is not necessarily significant but may indicate a possible future problem such as crossing a warning threshold Critical Error A significant event that indicates actual or imminent loss of data or loss of function such as crossing a failure threshold or a hardware failure Traps Instrumentation Traps This section describes the traps that are generated by the Instrumentation service of the Server Administrator All of the traps documented in this section belong to the MIB enterprise identified by OID 1 3 6 1 4 1 674 10892 1 and are sent with all of the trap variables documented in the section Trap Variables The trap variables are sent in the order in which they are listed The messages in the Description fields below show the format of the message that is sent in the alertMessage varbind If a message in a Description field has multiple lines the message contains newline 0Ah characters that are part of the value in the alertMessage varbi
422. ower cord and so on Syntax OCTET STRING SIZE 1 128 Access Read only System State AC Power Cord Status Combined Name systemStateACPowerCordStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 36 Description Defines the overall status of all AC power cords for any AC power switches in this chassis Syntax DellStatus Access Read only System State AC Power Cord Status Details Name systemStateACPowerCordStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 37 Description Defines the individual status of all AC power cords for any AC power switches in this chassis The first byte returned represents the status of the first AC power cord the second byte returned represents the status of the second AC power cord and so on Syntax OCTET STRING SIZE 1 128 Access Read only System State Group 63 System State Redundant Memory Unit State Details Name systemStateRedundantMemoryUnitStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 38 Description Defines the state of all redundant memory units in this chassis The results are returned as a binary octet string each byte of the octet string represents the state of the specific object The first byte returned represents the state of the first object and so on The bytes have the same definition type as DellStateSettings Syntax OCTET STRING SIZE 1 128 Access Read only System State Redundant Memory Unit Status Redundancy Name systemStateRedundantMem
423. ows setting of the power button control hardware Syntax DellPowerButtonControlSettings See Table 5 17 Access Read write Chassis Reseller Name Name chassisResellerName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 40 Description Defines the name of the chassis reseller Syntax DisplayString SIZE 0 128 Access Read only Chassis Reseller Contact Information Name Name chassisResellerContactInformationName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 41 Description Defines the chassis reseller contact information name Syntax DisplayString SIZE 0 128 Access Read only Chassis Reseller Product Name Name chassisResellerProductName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 42 Description Defines the chassis reseller product name Syntax DisplayString SIZE 0 128 Access Read only 82 Chassis Information Group Chassis Reseller System ID Name Object ID Description Syntax Access chassisResellerSystemID 1 3 6 1 4 1 674 10892 1 300 10 1 43 Defines the chassis reseller system ID DellUnsigned16BitRange Read only Chassis NMI Button Control Capabilities Unique Name Object ID Description Syntax Access chassisNMIButtonControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 300 10 1 44 Defines the capabilities of the NMI button control function DelINMIButtonControlCapabilities See Table 5 18 Read only Chassis NMI Button Control Settings Unique Name Object ID Description Syntax Access
424. p e Physical Devices Group e Logical Devices Group e Storage Management Event Group 27 Storage Management Alert Reference lets you monitor the NA health of storage resources such as controllers connectors array disks and virtual disks Introduction 27 Server Administrator Change Management MIB The Server Administrator Change Management MIB filename dellcm mib provides management data that allows you to monitor the inventory of devices and applications with SNMP management applications Table 1 6 describes each Server Administrator Change Management MIB group and lists the MIB group number assigned to the MIB group The Server Administrator Change Management MIB groups are identified by the SNMP OID 1 3 6 1 4 1 674 lt MIB group number gt where lt MIB group number gt is the MIB group number assigned to the MIB group See the relevant section for more information about the MIB objects defined in a MIB group Table 1 6 Server Administrator Change Management MIB Sections in This Guide Section Topics MIB Group Number 24 Change Management Group describes the inventory data 10899 provided by the Change Management MIB that allows users to monitor devices and software present on a particular managed computer chassis Dell RAC Out of Band MIB The Dell RAC Out of Band MIB filename dellRAC mib provides management data that allows you to monitor the Chassis Management Controller This MIB also contains inf
425. perCriticalThreshold 1 3 6 1 4 1 674 10892 1 700 20 1 10 Defines the value of the temperature probe s upper critical threshold DellSigned32BitRange Read only Thermal Group Temperature Probe Upper Noncritical Threshold Name Object ID Description Syntax Access temperatureProbeUpperNonCriticalThreshold 1 3 6 1 4 1 674 10892 1 700 20 1 11 Defines the user assigned value of the temperature probe s upper noncritical threshold DellSigned32BitRange Read write Temperature Probe Lower Noncritical Threshold Name Object ID Description Syntax Access temperatureProbeLowerNonCriticalThreshold 1 3 6 1 4 1 674 10892 1 700 20 1 12 Defines the user assigned value of the temperature probe s lower noncritical threshold DellSigned32BitRange Read write Temperature Probe Lower Critical Threshold Name Object ID Description Syntax Access temperatureProbeLowerCriticalThreshold 1 3 6 1 4 1 674 10892 1 700 20 1 13 Defines the value of the temperature probe s lower critical threshold DellSigned32BitRange Read only Temperature Probe Lower Nonrecoverable Threshold Name Object ID Description Syntax Access temperatureProbeLowerNonRecoverableThreshold 1 3 6 1 4 1 674 10892 1 700 20 1 14 Defines the value of the temperature probe s lower nonrecoverable threshold DellSigned32BitRange Read only Thermal Group 209 Temperature Probe Probe Capabilities
426. perage Probe Nonrecoverable 1205 Current sensor detected a Error A current sensor in the non recoverable valu specified system Sensor location a ZT GOCARTOR in Chase nee which it cannot recover The sensor location Chassis location lt Name of chassis location previous chassis gt state and current sensor Previous state was lt State gt value are provided If sensor type is not discret Current sensor value in Amps lt Reading gt If sensor type is discrete Discrete current state lt State gt Traps 709 Chassis Intrusion Traps Chassis intrusion traps are a security measure Chassis intrusion means that someone is opening the cover to a system s chassis Alerts are sent to prevent unauthorized removal of parts from a chassis Table 26 7 Chassis Intrusion Traps Trap ID Description Cause Chassis Intrusion Normal 1252 Chassis intrusion returned Information to normal Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt Chassis intrusion state lt Intrusion state gt A chassis intrusion sensor in the specified system detected that a cover was opened while the system was operating but has since been replaced The sensor location chassis location previous state and chassis intrusion state are provided Chassis Intrusion Detected 1254 Chassis intrusion detected Error Sensor location lt Loc
427. pplyTypelsOther 1 The power supply type is not one of the following powerSupplyTypelIsUnknown 2 The power supply type is unknown not known or not monitored powerSupplyTypelIsLinear 3 The power supply type is a linear power supply Power Group 185 Table 8 3 Power Supply Type Definitions continued Variable Name De 1 1PowerSupplyType Data Type Integer Possible Data Values Meaning of Data Value powerSupplyTypeIsSwitching 4 The power supply type is a switching power supply powerSupplyTypelIsBattery 5 The power supply type is a battery powerSupplyTypelsuUPS 6 The power supply type is an uninterruptable power supply powerSupplyTypeIsConverter 7 The power supply type is a power converter power supply powerSupplyTypelIsRegulator 8 The power supply type is a regulator power supply powerSupplyTypelIsAC 9 The power supply type is an AC power supply powerSupplyTypelIsDC 10 The power supply type is a DC power supply powerSupplyTypelIsVRM 11 The power supply type is a voltage regulator module VRM power supply Table 8 4 Power Supply Sensor State Variable Name De 1 1PowerSupplySensorState Data Type Integer Possible Data Values Meaning of Data Value presenceDetected 1 The power supply s presence is detected psFailureDetected 2 The power supply failure is detected predictiveFailure 4 The po
428. ption Defines the SD Card Unit Table Syntax SEQUENCE OF SdCardUnitTableEntry Access Not accessible SD Card Unit Table Entry Name sdCardUnitTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 Description Defines the SD Card Unit Table Entry Syntax SdCardUnitTableEntry Access Not accessible Device Group 311 Name sdCardUnitTableEntry Index sdCardUnitChassisIndex sdCardUnitIndex SD Card Unit Chassis Index Name sdCardUnitChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 1 Description Defines the index one based of the chassis that contains the SD Card unit Syntax DellObjectRange Access Read only SD Card Unit Index Name sdCardUnit Index Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 2 Description Defines the index one based of the SD Card unit Syntax DellObjectRange Access Read only SD Card Unit State Capabilities Name sdCardUnitStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 3 Description Defines the state capabilities of the SD Card unit Syntax DellStateCapabilities Access Read only SD Card Unit State Settings Name sdCardUnitStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 4 312 Device Group Name sdCardUnitStateSettings Description Defines the state settings of the SD Card unit Syntax DellStateSettings Access Read only SD Card Unit Redundancy Status Name sdCardUnitRedundancyStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 110 1 5 Description D
429. r Administrator Remote Access MIB Sections in This Guide Section Topic MIB Group Numbers 19 Remote Access Group provides information about remote 1700 access hardware that may be present in your system and defines variables for administrative users SNMP trap destinations modem configuration for dial up networking dial in configuration and dial out destinations Server Administrator Baseboard Management Controller ASF MIB The Server Administrator BMC MIB filename DcAsfSrv mib provides information about the traps sent by BMC The Server Administrator BMC MIB structures its MIB objects that provide related information The BMC MIB groups are identified by the SNMP OID 1 3 6 1 4 1 3183 1 1 lt MIB group number gt The BMC MIB adheres to ASF 2 0 standard and hence the enterprise ID is wired for management 3183 Server Administrator Field Replaceable Unit MIB The Server Administrator Field Replaceable Unit MIB filename dcs3fru mib provides information about field replaceable unit FRU hardware that may be present in your system The Server Administrator Field Replaceable Unit MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information Table 1 4 describes each Server Administrator Field Replaceable Unit MIB group and lists the MIB group number assigned to the MIB group The Server Administrator Field Replaceable Unit MIB groups are identified by the SNMP OID 1 3 6 1 4 1 67
430. r Profile table powerProfileTable powerProfileTableEntry powerProfileChassisIndex powerProfileIndex powerProfileSupportedProfiles powerProfileSetting powerProfileCustomCPUMgmtCapabilities powerProfileCustomCPUMgmtSetting powerProfileCustomMemoryMgmtCapabilities powerProfileCustomMemoryMgmtSetting Introduction 21 e powerProfileCustomFanMgmtCapabilities e powerProfileCustomFanMgmtSetting e Added the following Power Group variable values e DellPowerCapSetting e DellPowerCapCapabilities DellPowerProfileType e DellCPUPowerPerformanceManagement lype DellMemoryPowerPerformanceManagementType DellFanPowerPerformanceManagement Type Introduction to the SNMP Reference Guide This reference guide provides a formatted version of the Server Administrator Instrumentation MIB filename 10892 mib the Server Administrator Remote Access MIB filename des3rmt mib the Server Administrator Field Replaceable Unit MIB filename des3fru mib the Server Administrator Storage Management MIB filename destorag mib the Server Administrator Change Management MIB filename dellcm mib and the Dell RAC Out of Band MIB filename dellRAC mib that are released with the current version of Dell OpenManage Server Administrator Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects Content in this reference guide is organized as documented in the follow
431. r Switch Table 167 Amperage Probe Table 161 Battery Table 172 Power Supply Table 152 Power Unit Table 149 Power Usage Table 174 variable values 184 Index 757 Voltage Probe Table 156 Power Group tables 149 Processor Device Status Traps 719 Processor sensor detected a failure value 721 Processor sensor detected a warning value 720 Processor sensor returned to a normal state 720 Redundant Memory Unit Table 371 Remote Access Group Remote Access Table 468 Remote SNMP Trap Table 485 Remote User Administration Table 477 Remote User Dial In Configuration Table 94 Remote User Dial Out Table 497 Remote Flash BIOS Group variable values 222 S sample SNMP output 749 Slot Group System Slot Table 345 variable values 349 758 Index SNMP introduction to 38 SNMP MIB OIDs 40 SNMP security 41 SNMP traps 42 SNMP basic terminology fields 31 32 managed object 31 MIB 31 SNMP 30 variable 31 SNMP support configuring 739 SNMP tables 33 example 34 reference guide content 36 1 SNMP traps 741 Storage Management Event Group 653 Storage Management Information Group 545 System Resource Group Direct Memory Access Table 141 Input Output Port Table 132 Interrupt Table 138 Map Table 127 Memory Table 135 Owner Table 129 variable values 144 System State Table 51 345 systems management software 46 build number systems 46 description nam
432. r of the fan in the fanTable in the connection Syntax Integer Access Read only Fan Connection Enclosure Name Name fanConnectionEnclosureName Object ID 1 3 6 1 4 1 674 10893 1 20 130 8 1 4 Description Identifies the name of the enclosure as represented in Storage Management to which this fan belongs Syntax DisplayString Access Read only 610 Storage Management Group Fan Connection Enclosure Number Name Object ID Description fanConnectionEnclosureNumber 1 3 6 1 4 1 674 10893 1 20 130 8 1 5 Identifies the instance number of the enclosure in the enclosureTable to which this fan belongs Syntax Integer Access Read only Power Supply Table This table describes available properties for each power supply on the managed system The following object sets up the Power Supply Table Name powerSupplyTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 Description Defines the power supply table Syntax SEQUENCE OF PowerSupplyEntry Access Not accessible Power Supply Entry Name powerSupplyEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 Description Defines the power supply table entry Syntax PowerSupplyEntry Access Not accessible Index powerSupplyNumber Storage Management Group 611 Power Supply Number Name powerSupplyNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 1 Description Identifies the instance number of the power supply entry Syntax Integer Access Read only Power Supply Nam
433. rAdminStateSettings See Table 19 13 Access Read write Remote User Admin Status Name remoteUserAdminStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 6 Description Defines the status for this remote access user Syntax DellStatus Access Read only Remote User Admin User Name Name remot eUserAdminUserName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 7 Description Defines the user name for this remote access user Syntax DisplayString SIZE 0 19 Access Read write Remote User Admin User Password Name Name remoteUserAdminUserPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 8 Description Defines the password for this remote access user Syntax DisplayString SIZE 0 255 Access Read write Remote Access Group 479 Remote User Admin User Privilege Name remoteUserAdminUserPrivilege Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 9 Description Defines the privileges for this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote User Admin User Privilege Capabilities Name remot eUserAdminUserPrivilegeCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 10 Description Defines the privilege capabilities for this remote access user Syntax DisplayString SIZE 0 31 Access Read only Remote User Admin Alert Filter DRS Events Mask Name remoteUserAdminAlertFilterDrsEventsMask Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 11 Description Defines the DRS events filter mask
434. rDrsEventsMask Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 9 Description Defines the DRS events filter mask for this remote access SNMP trap destination Syntax DellUnsigned32BitRange Access Read write Remote SNMP Trap Filter System Events Mask Name remoteSNMPTrapFilterSysEventsMask Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 10 Description Defines the system events filter mask for this remote access SNMP trap destination Syntax DellUnsigned32BitRange Access Read write 488 Remote Access Group Remote SNMP Trap Filter DRS Capabilities Name remoteSNMPTrapFilterDrsCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 11 Description Defines the DRS events filter capabilities for this remote access SNMP trap destination Syntax DellUnsigned32BitRange Access Read only Remote SNMP Trap Filter System Capabilities Name remoteSNMPTrapFilterSysCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 12 Description Defines the system events filter capabilities of this remote access SNMP trap destination Syntax DellUnsigned32BitRange Access Read only Remote SNMP Trap Control Capabilities Name remoteSNMPTrapControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 13 Description Defines the control capabilities of this remote access SNMP trap destination Syntax DellRemoteSNMPTrapControlCapabilities See Table 19 20 Access Read only Remote SNMP Trap Control Settings Name remoteSNMPTrapControlSettings
435. rUpgradeIsByZIFSocket 4 Upgrade device is in a zero insertion force ZIF socket processorUpgradeIsByReplacement 5 Upgrade device is a replacement processorUpgradeIsNone 6 There is no upgrade device processorUpgradeIsByLIFSocket 7 pgrade device is in a low nsertion force LIF socket processorUpgradeIsBySlot1 8 Upgrade device is a SLOT 1 processor processorUpgradeIsBySlot2 9 Upgrade device is a SLOT 2 processor processorUpgradeIsBy370PinSocket 10 Upgrade device is a 370 pin socket processorUpgradeIsBySlotA 11 Upgrade is by Slot A processorUpgradeIsBySlotM 12 Upgrade is by Slot M processorUpgradeIsByScoket423 13 Upgrade is by Socket 423 processorUpgradeIsBySocketA 14 Upgrade is by Socket A Socket 462 processorUpgradeIsBySocket478 15 Upgrade is by Socket 478 processorUpgradeIsBySocket754 16 Upgrade is by Socket 754 processorUpgradeIsBySocket940 17 Upgrade is by Socket 940 320 Device Group Table 13 5 Processor Upgrade Information continued Variable Name De11ProcessorUpgradeInformation Data Type Integer Possible Data Values Meaning of Data Value processorUpgradelIsBySocket 939 18 Upgrade is by Socket 939 processorUpgradelsBySocketmPGA604 19 Upgrade is by Socket mPGAG 04 processorUpgradelsBySocketLGA771 20 Upgrade is by Socket LGA771 processorUpgradeIsBySocketLGA
436. rage Management The following object sets up the Array Disk Channel Connection Table Name arrayDiskChannelConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 Description Defines the array disk channel connection table Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry Access Not accessible 600 Storage Management Group Array Disk Channel Connection Entry Name arrayDiskChannelConnectionEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 Description Defines the array disk channel connection table entry Syntax ArrayDiskChannelConnectionEntry Access Not accessible Index array DiskEnclosureConnectionNumber Array Disk Channel Connection Number Name arrayDiskChannelConnectionNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 1 Description Identifies the instance number of the array disk channel connection entry Syntax Integer Access Read only Array Disk Channel Connection Array Disk Name Name arrayDiskChannelConnectionArrayDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 2 Description Identifies the name of the array disk in this connection as represented in Storage Management Syntax DisplayString Access Read only Array Disk Channel Connection Array Disk Number Name arrayDiskChannelConnectionArrayDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 3 Description Identifies the instance number of the array disk in the arrayDiskTable in this connection Syntax Integer Access Rea
437. rage Management Syntax DisplayString Access Read only Power Supply Roll Up Status Name powerSupplyRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 8 Description Severity of the power supply state This is the combined status of the power supply and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 614 Storage Management Group Power Supply Component Status Name Object ID Description powerSupplyComponentStatus 1 3 6 1 4 1 674 10893 1 20 130 9 1 9 Severity of the power supply state This is the combined status of the power supply and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Power Supply NexusID Name powerSupplyNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 10 Description Durable unique ID for this power supply Syntax DisplayString Access Read only Power Supply Revision Name Object ID Description Syntax Access powerSupplyRevision 1 3 6 1 4 1 674 10893 1 20 130 9 1 11 Indicates the revision number of the power supply in the enclosure DisplayString Read only Storage Management Group Power Supply Connection Table This table describes the connection between each power supply on the managed system and its enclosure Each enclosure number in the table corresponds to t
438. rage Probe Type Name Object ID Description Syntax Access amperageProbeTyp 1 3 6 1 4 1 674 10892 1 600 30 1 7 Defines the type of the amperage probe DellAmperageProbeType Read only Amperage Probe Location Name Name Object ID Description Syntax Access amperageProbeLocationName 1 3 6 1 4 1 674 10892 1 600 30 1 8 Defines the location name of the amperage probe in this chassis DellString Read only Amperage Probe Upper Nonrecoverable Threshold Name Object ID Description Syntax Access amperageProbeUpperNonRecoverableThreshold 1 3 6 1 4 1 674 10892 1 600 30 1 9 Defines the value of the amperage probe s upper nonrecoverable threshold The value is an integer representing the amperage in milliamperes that the probe is reading DellSigned32BitRange Read only Amperage Probe Upper Critical Threshold Name Object ID Description Syntax Access amperageProbeUpperCriticalThreshold 1 3 6 1 4 1 674 10892 1 600 30 1 10 Defines the value of the amperage probe s upper critical threshold DellSigned32BitRange Read only 164 Power Group Amperage Probe Upper Noncritical Threshold Name amperageProbeUpperNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 11 Description Defines the user assigned value of the amperage probe s upper critical threshold Syntax DellSigned32BitRange Access Read write Amperage Probe Lower Noncritical Threshold Name amperagePro
439. rap ID Description Severity Cause 1403 Memory device status is Warning A memory device correction lt status gt rate exceeded an acceptable Memory device aeeation value a o device eLbGHET On anche sieS status and location are provided Possible memory module event cause lt list of causes gt 1404 Memory device status is Error A memory device correction lt Status gt Memory device location lt Location in chassis gt Possible memory module event cause lt list of causes gt rate exceeded an acceptable value a memory spare bank was activated or a Uncorrectable Memory Event occurred The system continues to function normally except for a Uncorrectable Memory Event Clear the memory error on Uncorrectable Memory Event Replace the memory module identified in the message during the system s next scheduled maintenance The memory device status and location are provided Fan Enclosure Traps Some systems are equipped with a protective enclosure for fans Fan enclosure traps monitor enclosures for whether foreign objects are present and for how long a fan enclosure is absent from a chassis 716 Traps Table 26 11 Fan Enclosure Traps Trap Description Severity Cause ID Fan Enclosure Insertion 1452 Fan enclosure inserted Information A fan enclosure has been into system inserted into the specified wn tee location system The sensor Ree eae ee ser ee location and chassis location are pro
440. rce LIF socket connec COL Por tTypelIsSlotl1 8 The processor port connector type is a slot one connec COL Por tTypelIsSlot2 9 The processor port connector type is a slot two connec COL Por tTypeIs370PinSocket 10 The processor port connector type is a 370 pin socket PortGroup 255 Table 12 4 Memory Device Port Connector Types Variable Name De 1 1MemoryDevicePortConnectorType Data Type Integer Possible Data Value Meaning of Data Value connectorPortTypelsOther 1 The memory device port connector type is not one of the following connectorPortTypelsUnknown 2 The memory device port connector type is unknown connectorPortTypelIsSIMM 3 The memory device port connector type is a single in line memory module SIMM connectorPortTypelIsSIP 4 The memory device port connector type is a SIP connectorPortTypelIsAChip 5 The memory device port connector type is a chip connectorPortTypelIsDIP 6 The memory device port connector type is a dual in line package DIP connectorPortTypeIsZIP 7 The memory device port connector type is a ZIP connectorPortTypelsAProprietaryCard 8 The memory device port connector type is a proprietary card connectorPortTypeIsDIMM 9 The memory device port connector type is a dual in line memory module DIMM connectorPortTypelIsTSOP 10
441. rce Map index SystemResourceOwnerTableEntry Not accessible systemResourceOwnerchassisIndex systemResourceOwnerIndex System Resource Owner Chassis Index Name Object ID Description Syntax Access systemResourceOwnerchassisIndex 1 3 6 1 4 1 674 10892 1 500 20 1 1 Defines the index one based of this chassis DellObjectRange Read only System Resource Owner Index Name Object ID Description Syntax Access systemResourceOwnerIndex 1 3 6 1 4 1 674 10892 1 500 20 1 2 Defines the index of system resource owners for this chassis DellObjectRange Read only System Resource Owner State Capabilities Name Object ID Description Syntax Access 130 systemResourceOwnerStateCapabilities 1 3 6 1 4 1 674 10892 1 500 20 1 3 Defines the capabilities of this system resource owner DellStateCapabilities Read only System Resource Group System Resource Owner State Settings Name systemResourceOwnerStateSettings Object ID 1 3 6 1 4 1 674 10892 1 500 20 1 4 Description Defines the state settings of this system resource owner Syntax DellStateSettings Access Read write System Resource Owner Status Name systemResourceOwnerStatus Object ID 1 3 6 1 4 1 674 10892 1 500 20 1 5 Description Defines the status of this system resource owner Syntax DellStatus Access Read write System Resource Owner Interface Type Name systemResourceOwnerlInterfaceTyp Object ID 1 3 6 1 4 1 674 10892 1 500
442. rd systemSlotIsPCIExpressX1 166 The system slot type is a PCI Express x1 systemSlotIsPCIExpressX2 167 The system slot type is a PCI Express x2 systemSlotIsPCIExpressxX4 168 The system slot type is a PCI Express x4 systemSlotIsPCIExpressxX8 169 The system slot type is a PCI Express x8 systemSlotIsPCIExpressxX16 170 The system slot type is a PCI Express x16 systemSlotIsPCIExpressGen2 171 The system slot type is PCI Express Gen 2 systemSlotIsPCIExpressGen2X1 172 The system slot type is PCI Express Gen 2 xl system 354 SlotIsPCIExpressGen2X2 173 Slot Group The system slot type is PCI Express Gen 2 x2 Table 14 3 System Slot Type continued Variable Name De11SystemSlotType Data Type Integer Possible Data Values Meaning of Data Value systemSlotIsPCIExpressGen2X4 174 The system slot type is PCI Express Gen 2 x4 systemSlotIsPCIExpressGen2X8 175 The system slot type is PCI Express Gen 2 x8 systemSlotIsPCIExpressGen2X16 176 The system slot type is PCI Express Gen 2 x16 Table 14 4 System Slot Usage Variable Name De11SystemSlotUs Data Type Integer age Possible Data Values Meaning of Data Value systemSlotUsagelIsOther 1 The system slot usage is not one of following systemSlotUsageIsUnknown 2 The system slot usage is unknown systemSlotUsageIsAvailable 3 The system slot is available syst
443. rdTable Object ID 1 3 6 1 4 1 674 10892 1 300 80 Description Defines the Baseboard Table Syntax SEQUENCE OF BaseBoardTableEntry Access Not accessible 102 Chassis Information Group Baseboard Table Entry Name Object ID Description Syntax Access Index baseBoardTableEntry 1 3 6 1 4 1 674 10892 1 300 80 1 Defines the Baseboard Table entry BaseBoard TableEntry Not accessible baseBoardChassisIndex baseBoardIndex Baseboard Chassis Index Name Object ID Description Syntax Access baseBoardChassisIndex 1 3 6 1 4 1 674 10892 1 300 80 1 1 Defines the index one based of the associated chassis DellObjectRange Read only Baseboard Index Name Object ID Description Syntax Access baseBoardIndex 1 3 6 1 4 1 674 10892 1 300 80 1 2 Defines the index one based of the base board DellObjectRange Read only Baseboard State Capabilities Name Object ID Description Syntax Access baseBoardStateCapabilities 1 3 6 1 4 1 674 10892 1 300 80 1 3 Defines the state capabilities of the baseboard DellStateCapabilities Read only Chassis Information Group 103 Baseboard State Settings Name baseBoardStateSettings Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 4 Description Defines the state settings of the baseboard Syntax DellStateSettings Access Read write Baseboard Status Name baseBoardStatus Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 5 Description Defines the status of the baseboar
444. revStatus Object ID 1 3 6 1 4 1 674 10892 2 20 10 3 Description Defines the Previous Status of the Alerting Sub System Syntax DellStatus Access Read only DrsCASSChangeTime Name DrsCASSChangeTime Object ID 1 3 6 1 4 1 674 10892 2 20 10 4 Description Defines the timestamp of Most Recent Change of the Alerting Sub System Syntax TimeTicks Access Read only DrsCAMessage Name DrsCAMessage Object ID 1 3 6 1 4 1 674 10892 2 20 10 5 Description Defines the CSSD message of the CMC Alert Syntax DellString Access Read only 688 Dell RAC Out of Band Group Legacy Alerting The following MIB tables provide information on the RAC legacy alerting DRsAlertSystem Name DRsAlertSystem Object ID 1 3 6 1 4 1 674 10892 2 5000 10 1 Description Name of the system generating the alert Syntax OCTET STRING SIZE 0 255 Access Read only DRsAlertTableIndexOID Name DRsAlertTableIndexOID Object ID 1 3 6 1 4 1 674 10892 2 5000 10 2 Description Alert Index Object Identifier Syntax OBJECT IDENTIFIER Access Read Only DRsAlertMessage Name DRsAlertMessage Object ID 1 3 6 1 4 1 674 10892 2 5000 10 3 Description Message describing the alert Syntax OCTET STRING SIZE 0 1024 Access Read only Dell RAC Out of Band Group 689 DRsAlertCurrentStatus Name DRsAlertCurrentStatus Object ID 1 3 6 1 4 1 674 10892 2 5000 10 4 Description Current status of object causing the alert Syntax DellStatus Access Read only DRsAlertPreviou
445. ring Access Read only Baseboard Service Tag Name Name baseBoardServiceTagNam Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 13 Description Defines the baseboard service tag name Syntax DellString Access Read only Baseboard Piece Part ID PPID Name Name baseBoardPiecePart IDName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 14 Description Defines the baseboard PPID Syntax DellString Access Read only Baseboard Asset Tag Name Name baseBoardAssetTagName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 15 Description Defines the baseboard asset tag name Syntax DellString Access Read only 106 Chassis Information Group Chassis Information Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 5 1 Log Format Variable Name De 1 1 LogFormat Data Type Integer Possible Data Values Meaning of Data Value raw 1 The log is in the format received from the firmware ascii 2 The log is in ASCII format uniCode 3 The log is in Unicode format Table 5 2 Chassis Type Variable Name Del 1ChassisType Data Type Integer Possible Data Values Meaning of Data Value other 1 The chassis type is not one of the following unknown 2 The chassis type is unknown desktop 3 The chassis type is a desktop lowProfileDesktop 4 The chassis type is a low profile desktop pi
446. ription Syntax Access networkDeviceiSCSICapabilityFlags 1 3 6 1 4 1 674 10892 1 1100 90 1 27 Defines the Internet Small Computer System Interface iSCSI capability flags of the network device DellNetworkDeviceiSCSICapabilityFlags see Table 13 24 Read only Network Device iSCSI Enabled Name Object ID Description Syntax Access 308 networkDeviceiSCSIEnabled 1 3 6 1 4 1 674 10892 1 1100 90 1 28 Defines if iSCSI is enabled for the network device DellBoolean Read only Device Group Managed System Services Device Table Name managedSystemServicesDeviceTabl Object ID 1 3 6 1 4 1 674 10892 1 1100 100 Description Defines the Managed System Services Device Table Syntax SEQUENCE OF ManagedSystemServicesDeviceTableEntry Access Not accessible Managed System Services Device Table Entry Name managedSystemServicesDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 100 1 Description Defines the Managed System Services Device Table Entry Syntax ManagedSystemServicesDeviceTableEntry Access Not accessible Index managedSystemServicesDeviceChassisIndex managed SystemServices DeviceIndex Managed System Services Device Chassis Index Name managedSystemServicesDeviceChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 100 1 1 Description Defines the index one based of the chassis that contains the managed system services device Syntax DellObjectRange Access Read only Device Group
447. ription Syntax Access pointingPortStatus 1 3 6 1 4 1 674 10892 1 1000 10 5 Defines the status of the pointing port DellStatus Read only Pointing Port Security State Name Object ID Description Syntax Access pointingPortSecurityState 1 3 6 1 4 1 674 10892 1 1000 10 6 Defines the security settings of the pointing port DellPortSecurityState Read only Pointing Port Connector Type Name Object ID Description Syntax Access pointingPortConnectorType 1 3 6 1 4 1 674 10892 1 1000 10 7 Defines the connector type of the pointing port DellPointingPortConnectorType See Table 12 1 Read only PortGroup 227 Pointing Port Name Name Object ID Description Syntax Access pointingPortName 1 3 6 1 4 1 674 10892 1 1000 10 8 Defines the name of the pointing port DellString Read only Pointing Port BIOS Connector Type Name pointingPortBlOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 10 9 Description Defines the basic input output system BIOS connector type of the pointing port Syntax DellGenericPortConnectorlype Access Read only Keyboard Port Table Name keyboardPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 20 Description Defines the Keyboard Port Table Syntax IntegerKeyboardPortTableEntry Access Not accessible Keyboard Port Table Entry Name Object ID Description Syntax Access Index 228 keyboardPortTableEntry 1 3 6 1 4 1 674 10892 1 1000 20 1 Defin
448. ription Defines the display name of the BMC Syntax DellString Access Read only BMC Description Name Name bmcDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 7 Description Defines the description of the BMC Syntax DisplayString SIZE 0 255 Access Read only Baseboard Management Controller Group 523 BMC IPMI Version Name Name Object ID Description Syntax Access BMC GUID Name Object ID Description Syntax Access BMC Type Name Object ID Description Syntax Access bmcIPMIVersionName 1 3 6 1 4 1 674 10892 1 1900 10 1 8 Defines the version of the Intelligent Platform Management Interface IPMI specification that the BMC supports DellString Read only bmcGUID 1 3 6 1 4 1 674 10892 1 1900 10 1 9 Defines the Globally Unique ID GUID of the BMC OCTET STRING SIZE 16 Read only bmcType 1 3 6 1 4 1 674 10892 1 1900 10 1 10 Defines the type of the BMC DellManagementControllerType Read only BMC Module Name Name Object ID Description Syntax Access bmcModuleName 1 3 6 1 4 1 674 10892 1 1900 10 1 11 Defines the module name for the BMC The module name is present only on certain systems such as modular systems DellString Read only 524 Baseboard Management Controller Group BMC IPv4 URL Name Name bmcIPv4URLName Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 12 Description Defines the IPv4 URL for the BMC The URL is not present on all systems Syn
449. rmation index of the option information for this system DellUnsigned32BitRange Read write COO Options Description Name Name cooOptionsDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 5 Description Defines the option information description name Syntax DellCostofOwnershipString Access Read write COO Maintenance Table Name cooMaintenanceTable Object ID 1 3 6 1 4 1 674 10892 1 1600 80 Description Defines the COO Maintenance Table Syntax SEQUENCE OF CooMaintenanceTableEntry Access Not accessible COO Maintenance Table Entry Name Object ID Description Syntax Access Index cooMaintenanceTableEntry 1 3 6 1 4 1 674 10892 1 1600 80 1 Defines the COO Maintenance Table entry CooMaintenanceTableEntry Not accessible cooMaintenancechassisIndex cooMaintenanceIndex 450 Cost of Ownership Group COO Maintenance Chassis Index Name Object ID Description Syntax Access cooMaintenancechassisIndex 1 3 6 1 4 1 674 10892 1 1600 80 1 1 Defines the index one based of this chassis DellObjectRange Read only COO Maintenance Index Name Object ID Description Syntax Access cooMaintenanceIndex 1 3 6 1 4 1 674 10892 1 1600 80 1 2 Defines the index of this system s maintenance information DellObjectRange Read only COO Maintenance State Name Object ID Description Syntax Access cooMaintenanceState 1 3 6 1 4 1 674 10892 1 1600 80 1 3 Defines the state of this system s mai
450. robeTypelsDiscrete the value returned for this attribute is the discrete reading for the probe DellAmperageDiscreteReading See Table 8 9 Read only 166 Power Group AC Power Switch Table Name Object ID Description Syntax Access aCPowerSwitchTable 1 3 6 1 4 1 674 10892 1 600 40 Defines the AC Power Switch Table SEQUENCE OF ACPowerSwitchTableEntry Not accessible AC Power Switch Table Entry Name Object ID Description Syntax Access Index aCPowerSwitchTableEntry 1 3 6 1 4 1 674 10892 1 600 40 1 Defines the AC Power Switch Table entry ACPowerSwitchTableEntry Not accessible aCPowerSwitchchassisIndex aC PowerSwitchIndex AC Power Switch Chassis Index Name Object ID Description Syntax Access aCPowerSwitchChassisIndex 1 3 6 1 4 1 674 10892 1 600 40 1 1 Defines the index one based of the chassis containing this AC power switch DellObjectRange Read only AC Power Switch Index Name Object ID Description Syntax Access aCPowerSwitchIndex 1 3 6 1 4 1 674 10892 1 600 40 1 2 Defines the index one based of this AC power switch DellObjectRange Read only Power Group 167 AC Power Switch Capabilities Name aCPowerSwitchCapabilities Object ID 1 3 6 1 4 1 674 10892 1 600 40 1 3 Description Defines the capabilities of this AC power switch Syntax DellAC PowerSwitchCapabilities Access Read only AC Power Switch Settings Name aCPowerSwitchSettings Object I
451. roup 341 Table 13 24 Network Device iSCSI Capability Flags Variable Name De 1 1NetworkDeviceiSCSICapabilityFlags Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 Querying for iSCSI capability is not supported unknown 1 Querying for iSCSI capability is supported but query returned an error available 2 Device has iSCSI capability notAvailable 4 Device does not have iSCSI capability cannotBeDetermined 8 Querying for iSCSI capability is supported but an error prevented querying driverNotResponding 16 Querying for iSCSI capability is supported but driver did not respond to query 342 Device Group Table 13 25 Managed System Services Device Type Variable Name DellManagedSystemServicesDeviceTyp Data Type Integer Possible Data Values Meaning of Data Value baseDevice 0 Device type is base device optionalDevice 1 Device type is optional device Table 13 26 SD Card Device Type Variable Name DellSDCardDeviceType Data Type Integer Possible Data Values Meaning of Data Value other 1 Device type is other unknown 2 Device type is unknown hypervisor 3 Device type is Hypervisor vF lash 4 Device type is Virtual Flash vFlash Table 13 27 SD Card Device Config Capabilities Variable Name DellSDCardDeviceConfigCapab
452. rt dell com manuals For additional guidelines see the Securing an SNMP Environment article dated May 2003 in the Dell Power Solutions magazine This magazine is also available at www dell com powersolutions K NOTE Server Administrator provides support to enable or disable SNMP Set operations For more information on enabling or disabling SNMP Set operations in Server Administrator see the Dell OpenManage Server Administrator User s Guide or the Dell OpenManage Server Administrator Command Line Interface User s Guide Introduction 41 Management Actions Management actions can be performed using the SNMP Set command These actions can consist of configuring a phone number for the system s owner rebooting a system or changing the asset tag of the system See the previous section SNMP Security for limitations on Set operations SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations hard drive failures and so on Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data This method has its drawbacks If it is done frequently significant amounts of network bandwidth can be consumed If it is done infrequently the response to the fault condition may not occur in a timely fashion SNMP traps avoid these limitations of the polling method An SNMP trap is an asynchronous event indicating tha
453. rtual Disk Name Name virtualDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 2 Description Identifies the virtual disk s label generated by Storage Management or entered by the user Syntax DisplayString Access Read only Virtual Device Disk Name Name virtualDiskDeviceName Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 3 Description Identifies the device name used by this virtual disk s member disks Syntax DisplayString Access Read only 642 Storage Management Group Virtual Disk State Name Object ID Description Syntax Access virtualDiskState 1 3 6 1 4 1 674 10893 1 20 140 1 1 4 Identifies the current state of this virtual disk Possible states 0 Unknown 1 Ready The disk is accessible and has no known problems 2 Failed The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online 3 Online 4 Offline The disk is not accessible The disk may be corrupted or intermittently unavailable 6 Degraded The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online 15 Resynching 16 Regenerating 24 Rebuilding 26 Formatting 32 Reconstructing 35 Initializing 36 Background Initialization 38 Resynching Paused 52 Permanently Degraded 54 Degraded Redundancy Integer Read only Storage Management Group 643 Virtual Disk Severity Name virtualDiskSeverity Object ID 1 3 6 1 4
454. ry array ECC type is unknown memoryArrayECCTypelIsNone 3 The memory array ECC type is none memoryArrayECCTypelsParity 4 The memory array ECC type is parity memoryArrayECCTypelsSingleBitECC 5 The memory array ECC type is Correctable Memory Event ECC memoryArrayECCTypelsMultiBitECC 6 The memory array ECC type is Uncorrectable Memory Event ECC memoryArrayECCTypelIsCRC 7 The memory array ECC type is CRC Table 15 3 Physical Memory Configuration State Capabilities Variable Name De 1 1PhysicalMemoryConfigStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero There are no state capabilities unknownCapabilities 1 State capabilities are unknown enableCapable 2 Object enable disable is supported notReadyCapable 4 Object not ready is supported Memory Group 379 Table 15 4 Physical Memory Configuration State Settings Variable Name De11PhysicalMemoryConfigStateSettings Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero There are no state settings unknown 1 State settings are unknown enabled 2 Object is disabled offline 0 or enabled online 1 not Ready 4 Object not ready redundantMemorylIsActive 8 Redundant memory is active in use enabledAndRedundantMemoryIsActive 10 Redu
455. s Variable Name De11BITOSPasswordControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown 1 Setup BIOS password state is unknown passwordControlEnabled 2 Setup BIOS has password changes enabled passwordControlJumperDisabled 4 Setup BIOS has determined that password control has been disabled by a jumper Table 16 10 TPM Security Control Capabilities Variable Name De11TPMSecurityControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value offCapable 1 TPM security can be Off onWithPrebootMeasurementsCap TPM security can be On with Pre boot able 2 Measurements onWithoutPrebootMeasurements TPM security can be On without Pre boot Capable 4 Measurements Table 16 11 TPM Security Control Setting Variable Name De11TPMSecurityControlSetting Data Type Integer Possible Data Values Meaning of Data Value off 0 TPM security is Off onWithPrebootMeasurements 1 TPM security is On with Pre boot Measurements onWithoutPrebootMeasurements TPM security is On without Pre boot 2 Measurements BIOS Setup Control Group 413 Table 16 12 Parallel Port Control Capabilities Variable Name De11ParallelPortControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 enableCapable 2 Setup BIOS par
456. s 302 networkDeviceConnectionStatus 1 3 6 1 4 1 674 10892 1 1100 90 1 4 Defines the connection status of the network device DellNetworkDeviceConnectionStatus see Table 13 20 Read only Device Group Network Device Description Name Name networkDeviceDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 5 Description Defines the description of the network device Syntax DellString Access Read only Network Device Product Name Name networkDeviceProductName Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 6 Description Defines the product name of the network device Syntax DellString Access Read only Network Device Vendor Name Name networkDeviceVendorName Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 7 Description Defines the name of the vendor of the network device Syntax DellString Access Read only Network Device Service Name Name networkDeviceServiceNam Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 8 Description Defines the service name of the network device Syntax DellString Access Read only Device Group 303 Network Device Driver Image Path Name Name Object ID Description Syntax Access networkDeviceDriverImagePathName 1 3 6 1 4 1 674 10892 1 1100 90 1 9 Defines the path to the binary image of the driver for the network device DellString Read only Network Device Driver Version Name Name Object ID Description Syntax Access networkDevice
457. s pCIDeviceConfigurationSpaceHeader 1 3 6 1 4 1 674 10892 1 1100 82 1 10 Defines the common configuration space header of the PCI device OCTET STRING SIZE 0 1025 Read only Network Device Table Name Object ID Description Syntax Access networkDeviceTabl 1 3 6 1 4 1 674 10892 1 1100 90 Defines the Network Device Table SEQUENCE OF NetworkDeviceTableEntry Not accessible Network Device Table Entry Name Object ID Description Syntax Access Index networkDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 90 1 Defines the Network Device Table Entry NetworkDeviceTableEntry Not accessible networkDeviceChassisIndex networkDeviceIndex Device Group 301 Network Device Chassis Index Name Object ID Description Syntax Access networkDeviceChassisIndex 1 3 6 1 4 1 674 10892 1 1100 90 1 1 Defines the index one based of the chassis that contains the network device DellObjectRange Read only Network Device Index Name Object ID Description Syntax Access networkDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 90 1 2 Defines the index one based of the network device DellObjectRange Read only Network Device Status Name Object ID Description Syntax Access networkDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 90 1 3 Defines the status of the network device DellStatus Read only Network Device Connection Status Name Object ID Description Syntax Acces
458. s Event Name previousStatusEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 8 Description Previous status of object causing the alert if applicable Syntax DellStatus Access Read only Storage Management Group 655 656 Storage Management Group Change Management Group The Change Management Group lets you monitor information about the Dell devices and software that are present on a particular managed computer chassis This information is collected during an inventory scan Inventory Group The following objects describe the fields for inventory information Inventory Locale Name inventoryLocale Object ID 1 3 6 1 4 1 674 10899 1 1 Description Defines the locale of the system Syntax DisplayString Access Read only Inventory Schema Version Name inventorySchemaVersion Object ID 1 3 6 1 4 1 674 10899 1 2 Description Defines the inventory schema implemented by this system Syntax DisplayString Access Read only Inventory System ID Name inventorySystemID Object ID 1 3 6 1 4 1 674 10899 1 3 Description Defines the System ID for the system Syntax SystemID Change Management Group 657 658 Name Access inventorySystemID Read only Device Group The Device Group defines information about the devices discovered on the system during an inventory scan Identifying information includes the Component ID the Device ID and the Vendor ID Device Group Table The following object sets up the De
459. s Meaning of Data Value nonRedundant 1 The AC power switch is not expecting redundancy redundant 2 The AC power switch is expecting redundancy Table 8 13 AC Power Cord State Capabilities Variable Name De 1 1ACPowerCordStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The AC power cord s capabilities are unknown onlineCapable 2 The AC power cord can be disabled offline or enabled online notReadyCapable 4 The AC power cord s capabilities are not ready 192 Power Group Table 8 14 AC Power Cord State Settings Variable Name De 1 1ACPowerCordStateSettings Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The AC power cord s state is unknown online 2 The AC power cord s state is disabled offline 0 or enabled online 1 not Ready 4 The AC power cord s state is not ready acPowerCordHasPower The AC power cord has power 8 acPowerCordIsActive The AC power cord is the active source of Source 16 AC power Table 8 15 Battery Reading Variable Name De 1 1BatteryReading Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value predictiveFailure 1 Battery sensor detects predictive failure failed 2 Battery has failed presenceDetected 4 Battery presence is
460. s Read only Network Device Permanent MAC Address Name networkDevicePermanentMACAddress Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 16 Description Defines the permanent MAC address of the network device Syntax DellIMACAddress Access Read only Device Group 305 Network Device PCI Bus Number Name Object ID Description Syntax Access networkDevicePCIBusNumber 1 3 6 1 4 1 674 10892 1 1100 90 1 17 Defines the PCI bus number of the network device DellUnsigned8BitRange Read only Network Device PCI Device Number Name Object ID Description Syntax Access networkDevicePCIDeviceNumber 1 3 6 1 4 1 674 10892 1 1100 90 1 18 Defines the PCI device number of the network device DellUnsigned8BitRange Read only Network Device PCI Function Number Name networkDevicePCIFunctionNumber Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 19 Description Defines the PCI function number of the network device Syntax DellUnsigned8BitRange Access Read only Network Device IRQ Name networkDeviceIRQ Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 20 Description Defines the interrupt request number of the network device Syntax DellUnsigned32BitRange Access Read only 306 Device Group Network Device Base 10 Port Address Name Object ID Description Syntax Access networkDeviceBaselOPortAddress 1 3 6 1 4 1 674 10892 1 1100 90 1 21 Defines the base input outport port address of the network device DellUnsigned3
461. s a binary octet string Each byte of the octet string represents the status of a specific voltage probe The first byte returned represents the status of the first voltage probe the second byte returned represents the status of the second voltage probe and so on The bytes have the same definition type as DellStateSettings Syntax OCTET STRING SIZE 1 128 Access Read only System State Voltage Status Combined Name systemStateVoltageStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 12 Description Defines the status of all voltage probes in this chassis Syntax DellStatus Access Read only System State Voltage Status Details Name systemStateVoltageStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 13 Description Defines the status of all voltage probes in this chassis Syntax OCTET STRING SIZE 1 128 Access Read only System State Group 55 System State Amperage State Details Name systemStateAmperageStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 14 Description Defines the state of all current probes in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific current probe The first byte returned represents the state of the first current probe the second byte returned represents the state of the second current probe and so on The bytes have the same definition type as DellStateSettings Syntax OCTET STRING SI
462. s application alert log If you have SNMP installed on the managed system and the SNMP service is running the Storage Management alerts in the Windows application alert log will be forwarded as SNMP traps In order for these traps to be viewable however a target system or application must be configured to receive these traps SNMP traps that are generated by Storage Management can be viewed in any standard SNMP compatible enterprise management console Storage Management Alert Reference 739 The Windows SNMP service must be configured to forward the SNMP traps to the target system or application When forwarding to an application the application should also be configured to receive the SNMP traps The IT Assistant application is already configured to receive the SNMP traps generated by Storage Management See your Windows operating system documentation for information on configuring the operating system to forward SNMP traps This information may be located under such topics as setting up SNMP or SNMP traps When configuring SNMP for Windows be sure that the SNMP traps are forwarded to the correct server For information on configuring an application to receive SNMP traps see the documentation for that application SNMP Trap Definitions The Storage Management management information base MIB defines the SNMP traps that Storage Management generates These traps correspond to the alerts documented in the Alert Descriptio
463. s okay not Supported 2 FRU information is not supported notAvailable 3 FRU information is not available checksumInvalid 4 FRU information checksum is invalid corrupted 5 FRU information is corrupted Field Replaceable Unit Group 541 542 Field Replaceable Unit Group Storage Management Group The Storage Management Group is composed of the following Storage Management Group information about the software product and system status e Storage Management Information Group properties about the Simple Network Management Protocol SNMP agent e Global Data Group system status e Physical Devices Group physical devices managed by the software e Logical Devices Group logical devices managed by the software Storage Management Event Group SNMP traps Storage Management Group The Storage Management Information Base MIB Group defines the properties that identify information about the Storage Management software product and the current status of the system it manages Software Version Name softwareVersion Object ID 1 3 6 1 4 1 674 10893 1 20 1 Description Identifies the version number of the storage management component of the systems management software Syntax DisplayString Access Read only Storage Management Group 543 Global Status Name globalStatus Object ID 1 3 6 1 4 1 674 10893 1 20 2 Description Identifies global health for the subsystem managed by the Storage Managemen
464. s the number of memory devices that form a single row in the memory array mapped address A zero 0 indicates that the number is unknown DellUnsigned32BitRange Read only Physical Memory Configuration Table This table defines how the physical memory of a system chassis is set up for example which redundant memory types are supported and whether redundant memory is active The following object sets up the Physical Memory Configuration Table Name Object ID Description Syntax Access physicalMemoryConfigTable 1 3 6 1 4 1 674 10892 1 1300 30 Defines the Physical Memory Configuration Table SEQUENCE OF PhysicalMemoryConfigTableEntry Not accessible Physical Memory Configuration Table Entry Name Object ID Description Syntax Access Index physicalMemoryConfigTableEntry 1 3 6 1 4 1 674 10892 1 1300 30 1 Defines the Physical Memory Configuration Table entry PhysicalMemoryConfig TableEntry Not accessible physicalMemoryConfigChassisIndex physicalMemoryConfigIndex Memory Group _ 367 Physical Memory Configuration Chassis Index Name Object ID Description Syntax Access physicalMemoryConfigChassisIndex 1 3 6 1 4 1 674 10892 1 1300 30 1 1 Defines the index one based of the chassis associated with the physical memory configuration DellObjectRange Read only Physical Memory Configuration Index Name Object ID Description Syntax Access physicalMemoryConfigIndex 1 3 6 1 4 1
465. sGood 1 The temperature probe discrete reading is good temperatureIsBad 2 The temperature probe discrete reading is bad Thermal Group 213 214 Thermal Group User Security Group The User Security Table defines the objects that allow administrators to create and modify user accounts and to control which users can perform Set operations on managed systems User Security Group Table The User Security Group defines objects in the User Security MIB table User Security Table The following object sets up the User Security Table Name userSecurityTable Object ID 1 3 6 1 4 1 674 10892 1 800 Description Contains the database of users that are authorized to perform Set operations on a managed system Syntax UserSecurityTableEntry Access Not accessible User Security Table Entry Name userSecurityTableEntry Object ID 1 3 6 1 4 1 674 10892 1 800 1 Description Defines a row in the User Security Table Syntax UserSecurityTableEntry Access Not accessible Index userSecuritychassisIndex userSecurityIndex User Security Group 215 User Security Chassis Index Name userSecuritychassisIndex Object ID 1 3 6 1 4 1 674 10892 1 800 1 1 Description Defines the user security index one based of this chassis Syntax DellObjectRange Access Read only User Security Index Name userSecurityIndex Object ID 1 3 6 1 4 1 674 10892 1 800 1 2 Description Defines the user security index Syntax DellObjectRange Access Read only
466. sStatus Name DRsAlertPreviousStatus Object ID 1 3 6 1 4 1 674 10892 2 5000 10 5 Description Previous status of object causing the alert Syntax DellStatus Access Read only DRsAlertData Name DRsAlertData Object ID 1 3 6 1 4 1 674 10892 2 5000 10 6 Description Alert data Syntax OCTET STRING SIZE 0 1024 Access Read only 690 Dell RAC Out of Band Group Traps The Server Administrator generates events that result in Simple Network Management Protocol SNMP traps or operating system event logs Remote Access Controller RAC and Baseboard Management Controller BMC also can generate SNMP traps in response to hardware events This section describes the traps also known as alerts generated by the Server Administrator RAC and BMC The Server Administrator generates events in response to changes in the status of sensors and other monitored parameters When an event with predefined characteristics occurs on your system the SNMP subagent sends information about the event along with trap variables to the management console Each status change event generates a unique identifier called the trap ID and a trap description that describes the event The trap ID and message uniquely describe the severity and cause of the event and provide other relevant information such as the location of the event and the monitored item s previous state Instrumentation Traps lists all Server Administrator Instrumentation trap IDs in num
467. sabled offline a binary 0 value or enabled online a binary 1 value notReady 4 The chassis identification control s state is not ready Chassis Information Group 111 Table 5 10 Chassis Identification Control Settings continued Variable Name De11ChassisIdentifyControlSettings Data Type Integer Possible Data Values Meaning of Data Value identifyChassis 8 The chassis identification control s LEDs may be returned to normal 0 or identify chassis 1 identifyChassisAndEnable The chassis identification control s 10 LEDs may be returned to normal a binary 0 value or identify chassis and enabled a binary value Table 5 11 Host Control Capabilities Variable Name Del 1HostControlCapabilities NOTE An operator can manually enable these actions using SNMP Data Type Integer Possible Data Values Meaning of Data Value manualRebootCapable 1 The operator can reboot capable host manualPowerOFFCapable 2 The operator can power off capable host manualPowerCycleCapable 4 The operator can power cycle capable host manualAllExceptOperating The operator can reboot and power off SystemShutdownCapable 7 _ capable host manualOperatingSystemShut The operator can shut down the downCapable 8 operating system shutdown capable host manualFullyCapable 15 The operator can reboot power on and off the power cycle capable host and shut down the
468. scription Syntax Access physicalMemoryArraychassisIndex 1 3 6 1 4 1 674 10892 1 1300 10 1 1 Defines the index one based of this chassis DellObjectRange Read only Physical Memory Array Index Name Object ID Description Syntax Access 360 physicalMemoryArrayIndex 1 3 6 1 4 1 674 10892 1 1300 10 1 2 Defines the index one based of the physical memory array in this chassis DellObjectRange Read only Memory Group Physical Memory Array State Capabilities Name Object ID Description Syntax Access physicalMemoryArrayStateCapabilities 1 3 6 1 4 1 674 10892 1 1300 10 1 3 Defines the capabilities of the physical memory array DellStateCapabilities Read only Physical Memory Array State Settings Name Object ID Description Syntax Access physicalMemoryArrayStateSettings 1 3 6 1 4 1 674 10892 1 1300 10 1 4 Defines the state of the physical memory array DellStateSettings read write Physical Memory Array Status Name Object ID Description Syntax Access physicalMemoryArrayStatus 1 3 6 1 4 1 674 10892 1 1300 10 1 5 Defines the status of the physical memory array DellStatus Read only Physical Memory Array Use Name Object ID Description Syntax Access physicalMemoryArrayUse 1 3 6 1 4 1 674 10892 1 1300 10 1 6 Defines the use of the physical memory array DellPhysicalMemoryArrayUse See Table 15 2 Read only Memory Group _ 361 Physical Memory Array Error
469. sents the state of the second cooling unit and so on The bytes have the same definition type as DellStateSettings OCTET STRING SIZE 1 128 Read only System State Cooling Unit Status Redundancy Name Object ID Description Syntax Access systemStateCoolingUnitStatusRedundancy 1 3 6 1 4 1 674 10892 1 200 10 1 18 Defines the state of all cooling units in this chassis DellStatusRedundancy Read only System State Cooling Unit State Details Name Object ID Description Syntax Access systemStateCoolingUnitstateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 19 Defines the state of all cooling units in this chassis The results are returned as a binary octet string Each byte of the octet string represents the state of a specific cooling unit The first byte returned represents the state of the first cooling unit the second byte returned represents the state of the second cooling unit and so on The bytes have the same definition type as DellStateSettings OCTET STRING SIZE 1 128 Read only System State Group 57 System State Cooling Device State Details Name systemStateCoolingDeviceStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 20 Description Defines the state of all cooling devices in this chassis The results are returned as a binary octet string Each byte of the octet string represents the state of a specific cooling device The first byte returned represents the state of the first cooling de
470. setting Syntax DellPowerProfileType Access Read only Power Profile Custom CPU Mgmt Capabilities Name powerProfileCustomCPUMgmtCapabilities Object ID 1 3 6 1 4 1 674 10892 1 600 70 1 5 Description Defines the custom CPU power and performance management capabilities that are available for the Custom power profile Syntax DellCPUPowerPerformanceManagementType Access Read only Power Profile Custom CPU Mgmt Setting Name powerProfileCustomCPUMgmt Setting Object ID 1 3 6 1 4 1 674 10892 1 600 70 1 6 182 Power Group Description Syntax Access powerProfileCustomCPUMgmt Setting Defines the custom CPU power and performance management setting for the Custom power profile DellCPUPowerPerformanceManagementType Read only Power Profile Custom Memory Mgmt Capabilities Name Object ID Description Syntax Access powerProfileCustomMemoryMgmtCapabilities 1 3 6 1 4 1 674 10892 1 600 70 1 7 Defines the custom memory power and performance management capabilities that are available for the Custom power profile DellMemoryPowerPerformanceManagement Type Read only Power Profile Custom Memory Mgmt Setting Name Object ID Description Syntax Access powerProfileCustomMemoryMgmt Setting 1 3 6 1 4 1 674 10892 1 600 70 1 8 Defines the custom memory power and performance management setting for the Custom power profile DellMemoryPowerPerformanceManagement Type Read only Power Profile Custom Fan Mgm
471. sible COO Schedule Number Table Entry Name Object ID Description Syntax Access Index cooScheduleNumberTableEntry 1 3 6 1 4 1 674 10892 1 1600 60 1 Defines the COO Schedule Number Information Table entry CooScheduleNumberTableEntry Not accessible cooScheduleNumberchassisIndex cooScheduleNumberIndex COO Schedule Number Chassis Index Name Object ID Description Syntax Access cooScheduleNumberchassisIndex 1 3 6 1 4 1 674 10892 1 1600 60 1 1 Defines the index one based of this chassis DellObjectRange Read only COO Schedule Number Index Name Object ID Description Syntax Access cooScheduleNumberIndex 1 3 6 1 4 1 674 10892 1 1600 60 1 2 Defines the index of the schedule number information DellObjectRange Read only Cost of Ownership Group 447 COO Schedule Number State Name cooScheduleNumberStat Object ID 1 3 6 1 4 1 674 10892 1 1600 60 1 3 Description Defines the schedule number information state of this system Syntax DellStateSettings Access Read only COO Schedule Number Lease Information Index Reference Name cooScheduleNumberLeaseInformationIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1600 60 1 4 Description Defines the lease information index number to reference the schedule number Syntax DellUnsigned32BitRange Access Read write COO Schedule Number Description Name Name cooScheduleNumberDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1600 60 1 5
472. sible Index controllerNumber Controller Number Name controllerNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 1 Description Identifies the instance number of the controller entry Syntax Integer Access Read only Controller Name Name controllerName Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 2 Description Identifies the name of the controller in this subsystem as represented in Storage Management Includes the controller type and instance For example PERC 3 QC 1 Syntax DisplayString Access Read only 554 Storage Management Group Controller Vendor Name controllerVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 3 Description Identifies the controller s re seller s name Syntax DisplayString Access Read only Controller Type Name controllerType Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 4 Description Identifies the type of this controller 1 SCSI 2 PowerVault 660F 3 Power Vault 662F 4 Integrated Intelligent Drive Electronics IDE 5 Serial Advanced Technology Architecture SATA 6 Serial Attached SCSI SAS Syntax Integer Access Read only Storage Management Group 555 Controller State Name controllerState Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 5 Description Identifies the status of the controller s subsystem which includes any devices connected to it Possible states 0 Unknown 1 Ready 2 Failed 3 Online 4 Offline 6 Degraded Syntax Integer Access Read
473. sible Data Values Meaning of Data Value unknown 1 The LED control setting is unknown alertOnError 2 The LED control is set to alert on an error condition alertOnWarningAndError 4 The LED control is set to alert on an error or a warning condition Chassis Information Group 109 Table 5 7 Hard Drive Fault LED Control Capabilities Variable Name De 11 HDFaultL Data Type Integer EDControlCapabilities Possible Data Values Meaning of Data Value none 0 The hard drive has no fault LED capabilities unknownCapabilities 1 The hard drive fault LED capabilities are unknown enableCapable 2 The hard drive fault LED can be disabled offline a binary 0 value or enabled online a binary 1 value notReadyCapable 4 The hard drive fault LED can indicate not ready resetCapable 8 The hard drive fault LED can be reset Table 5 8 Hard Drive Fault LED Control Settings Variable Name De11HDFaultLEDControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The LEDs do not have any fault settings capabilities unknown 1 The hard drive fault LEDs state is unknown enabled 2 The hard drive fault LEDs state is disabled offline a binary 0 value or enabled online a binary 1 value notReady 4 The hard drive fault LEDs state is not ready reset 8 T
474. sicalMemoryArrayMappedTable 1 3 6 1 4 1 674 10892 1 1300 20 Defines the Physical Memory Array Mapped Table PhysicalMemoryArrayMappedTableEntry Not accessible Physical Memory Array Mapped Table Entry Name Object ID Description Syntax Access Index 364 PhysicalMemoryArrayMappedTableEntry 1 3 6 1 4 1 674 10892 1 1300 20 1 Defines the Physical Memory Array Mapped Table entry PhysicalMemoryArrayMappedTableEntry Not accessible physicalMemoryArrayMappedchassisIndex physicalMemoryArrayMappedIndex Memory Group Physical Memory Array Mapped Chassis Index Name Object ID Description Syntax Access physicalMemoryArrayMappedchassisIndex 1 3 6 1 4 1 674 10892 1 1300 20 1 1 Defines the index one based of this chassis DellObjectRange Read only Physical Memory Array Mapped Index Name Object ID Description Syntax Access physicalMemoryArrayMappedIndex 1 3 6 1 4 1 674 10892 1 1300 20 1 2 Defines the index one based of the memory array mapped address in this chassis DellObjectRange Read only Physical Memory Array Mapped State Capabilities Name Object ID Description Syntax Access physicalMemoryArrayMappedStateCapabilities 1 3 6 1 4 1 674 10892 1 1300 20 1 3 Defines the capabilities of the memory array mapped address DellStateCapabilities Read only Physical Memory Array Mapped State Settings Name Object ID Description Syntax Access physicalMemoryArrayMappedStateSe
475. sing the attribute will have memoryDeviceErrorCount 1 3 6 1 4 1 674 10892 1 1100 50 1 9 Defines the total number of Error Checking and Correction ECC errors detected by the memory device Writing a 0 zero to this variable will reset the devices error counts DellSigned32BitRange Read write Memory Device Bank Location Name Name Object ID Description Syntax Access memoryDeviceBankLocationName 1 3 6 1 4 1 674 10892 1 1100 50 1 10 Defines the bank location name of the memory device DellString Read only Memory Device Type Details Name Object ID Description Syntax Access 284 memoryDeviceTypeDetails 1 3 6 1 4 1 674 10892 1 1100 50 1 11 Defines the detailed type of the memory device DellMemoryDeviceTypeDetails See Table 13 17 Read only Device Group Memory Device Form Factor Name memoryDeviceFormFactor Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 12 Description Defines the form factor of the memory device Syntax DellMemoryDeviceFormFactor See Table 13 15 Access Read only Memory Device Set Name memoryDeviceSet Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 13 Description Defines if the memory device is a part of a set A zero 0 indicates that this device is not part of a set Syntax DellUnsigned32BitRange Access Read only Memory Device Size Name memoryDeviceSiz Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 14 Description Defines the size in KB of the memory device Sy
476. ss Index arrayDiskEnclosureConnectionEntry 1 3 6 1 4 1 674 10893 1 20 130 5 1 Defines the array disk enclosure connection table entry ArrayDiskEnclosureConnectionEntry Not accessible array DiskEnclosureConnectionNumber Array Disk Enclosure Connection Number Name Object ID Description Syntax Access arrayDiskEnclosureConnectionNumber 1 3 6 1 4 1 674 10893 1 20 130 5 1 1 Identifies the instance number of the array disk enclosure connection entry Integer Read only Array Disk Enclosure Connection Array Disk Name Name Object ID Description Syntax Access arrayDiskEnclosureConnectionArrayDiskName 1 3 6 1 4 1 674 10893 1 20 130 5 1 2 Identifies the name of the array disk in this connection as represented in Storage Management DisplayString Read only 598 Storage Management Group Array Disk Enclosure Connection Array Disk Number Name Object ID Description Syntax Access arrayDiskEnclosureConnectionArrayDiskNumber 1 3 6 1 4 1 674 10893 1 20 130 5 1 3 Identifies the instance number of the array disk in the arrayDiskTable in this connection Integer Read only Array Disk Enclosure Connection Enclosure Name Name Object ID Description Syntax Access arrayDiskEnclosureConnectionEnclosureName 1 3 6 1 4 1 674 10893 1 20 130 5 1 4 Identifies the name of the enclosure as represented in Storage Management to which this array disk belongs Displ
477. ss Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 28 Description Indicates the specified SAS address if this is a SAS disk Syntax DisplayString Access Read only Array Disk Negotiated Speed Name Object ID Description Syntax Access arrayDiskNegotiatedSpeed 1 3 6 1 4 1 674 10893 1 20 130 4 1 29 Indicates the speed at which the drive is actually running in MPS megabytes per second Integer Read only Array Disk Capable Speed Name Object ID Description Syntax Access arrayDiskCapableSpeed 1 3 6 1 4 1 674 10893 1 20 130 4 1 30 Indicates the maximum speed at which the drive is capable of negotiating in MPS megabytes per second Integer Read only Storage Management Group 595 Array Disk Smart Alert Indication Name arrayDiskSmartAlertIndication Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 31 Description Indicates whether the disk has received a predictive failure Possible values 1 No disk has not received a predictive failure alert 2 Yes disk has received a predictive failure alert Syntax Integer Access Read only Array Disk Manufacture Day Name arrayDiskManufactureDay Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 32 Description Indicates the day of the week 1 Sunday through 7 Saturday on which this disk was manufactured Syntax DisplayString Access Read only Array Disk Manufacture Week Name arrayDiskManufactureWeek Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 33 Des
478. ssible Data Values Meaning of Data Value unknownCapabilities 1 The AC power switch s capabilities are unknown input SourceCord1lNoReturnCapable 2 Input source is AC power cord 1 with no return input SourceCordlReturnCapable 4 Input source is AC power cord 1 with return input SourceCord2NoReturnCapable 8 Input source is AC power cord 2 with no return input SourceCord2ReturnCapable 16 Input source is AC power cord 2 with return input SourceSharedCapable 32 Input source is shared Table 8 11 AC Power Switch Settings Variable Name De 1 1ACPowerSwitchSettings Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The AC power switch s settings are unknown input SourceCord1NoReturn 2 Input source is AC power cord 1 with no return Power Group 191 Table 8 11 AC Power Switch Settings continued Variable Name De 1 1ACPowerSwitchSettings Data Type Integer Possible Data Values Meaning of Data Value inputSourceCord1Return 4 Input source is AC power cord 1 with return input SourceCord2NoReturn 8 Input source is AC power cord 2 with no return input SourceCord2Return 16 Input source is AC power cord 2 with return input SourceShared 32 Input source is shared Table 8 12 AC Power Switch Redundancy Mode Variable Name De 1 1ACPowerSwitchRedundancyMode Data Type Integer Possible Data Value
479. ssor family is AMD Athlon X2 Dual Core deviceFamilyIsPA RISC 144 The processor family is PA RISC deviceFamilyIsPA RISC8500 145 The processor family is PA RISC 8500 deviceFamilyIsPA RISC8000 146 The processor family is PA RISC 8000 deviceFamilyIsPA RISC7300LC 147 The processor family is PA RISC 7300LC deviceFamilyIsPA RISC7200 148 The processor family is PA RISC 7200 deviceFamilyIsPA RISC7100LC 149 The processor family is PA RISC 7100LC deviceFamilyIsPA RISC7100 150 The processor family is PA RISC 7100 deviceFamilyIsv30 160 The processor family is V30 deviceFamilyIsQuadCoreIntelXxXeo n3200 161 The processor family is Quad Core Intel Xeon processor 3200 Series deviceFamilyIsDualCoreIntelXeo n3000 162 The processor family is Dual Core Intel Xeon processor 3000 Series deviceFamilyIsQuadCoreIntelXeo n5300 163 326 Device Group The processor family is Quad Core Intel Xeon processor 5300 Series Table 13 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreIntelxeo The processor family is Dual Core Intel n5100 164 Xeon processor 5100 Series deviceFamilyIsDualCoreIntelxeo The processor family is Dual Core Intel n5000 165 X
480. sswordControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 31 Description Defines the capabilities of user password control Syntax DellBIOS PasswordControlCapabilitiesUnique Access Read only BIOS Setup Control Group 391 BIOS Setup Control User Password Control Settings Unique Name bSUCuserPasswordControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 32 Description Defines the control settings for user password control Syntax DellBIOSPasswordControlSettingsUnique See Table 16 9 Access Read write BIOS Setup Control User Password Control Status Name bSUCuserPasswordControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 33 Description Defines the status of the user password control Syntax DellStatus Access Read only BIOS Setup Control User Password Verify Name Name bSUCuserPasswordVerifyName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 34 Description Defines the setup BIOS name of the current user password Syntax DellString Access Read write BIOS Setup Control User Password New Password Name Name bSUCuserPasswordNewPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 35 Description Defines the setup BIOS name of the new user password To set a new user password a you must have successfully set the current user password immediately preceding this password change Syntax DellString Access Read write 392 BIOS Setup Control Group BIOS Setup Control TPM Security Control
481. stance number in the appropriate MIB table for that object where all of the object properties can be found The following object sets up the Array Disk Logical Connection Table 650 Storage Management Group Name Object ID Description Syntax Access arrayDiskLogicalConnectionTable 1 3 6 1 4 1 674 10893 1 20 140 3 Defines the array disk logical connection table SEQUENCE OF arrayDiskLogicalConnectionEntry Not accessible Array Disk Logical Connection Entry Name Object ID Description Syntax Access Index arrayDiskLogicalConnectionEntry 1 3 6 1 4 1 674 10893 1 20 140 3 1 Defines the array disk logical connection table entry ArrayDiskLogicalConnectionEntry Not accessible array DiskLogicalConnectionNumber Array Disk Logical Connection Number Name Object ID Description Syntax Access arrayDiskLogicalConnectionNumber 1 3 6 1 4 1 674 10893 1 20 140 3 1 1 Identifies the instance number of the disk entry Integer Read only Array Disk Logical Connection Array Disk Name Name Object ID Description Syntax Access arrayDiskLogicalConnectionArrayDiskName 1 3 6 1 4 1 674 10893 1 20 140 3 1 2 Identifies the name of the array disk in this logical connection DisplayString Read only Storage Management Group 651 Array Disk Logical Connection Array Disk Number Name arrayDiskLogicalConnectionArrayDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 3 Description Identifies the instance n
482. state and settings of the amperage probe Syntax DellStateSettings Access Read write 162 Power Group Amperage Probe Status Name Object ID Description amperageProbeStatus 1 3 6 1 4 1 674 10892 1 600 30 1 5 Defines the status of the amperage probe Syntax DellSigned32BitRange Access Read only Amperage Probe Reading Name amperageProbeReading Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 6 Description Syntax Access Defines the reading for an amperage probe of type other than amperageProbeTypelsDiscrete When the value for amperageProbeType is amperageProbelypelsPowerSupplyAmps or amperageProbelypelsSystemAmps the value returned for this attribute is the power usage that the probe is reading in tenths of Amperes When the value for amperageProbeType is amperageProbe lypelsPowerSupply Watts or amperageProbe TypelsSystem Watts the value returned for this attribute is the power usage that the probe is reading in Watts When the value for amperageProbeType is other than amperageProbeTypelsDiscrete amperageProbe lypelsPowerSupplyAmps amperageProbe lypelsPowerSupply Watts amperageProbe TypelsSystemAmps or amperageProbe lypelsSystem Watts the value returned for this attribute is the amperage that the probe is reading in Milliamps When the value for amperageProbeType is amperageProbelypelsDiscrete a value is not returned for this attribute DellSigned32BitRange Read only Power Group 163 Ampe
483. status of the first SD Card device and so on The bytes have the same definition type as DellStatus Syntax OCTET STRING SIZE 1 128 Access Read only 70 System State Group Chassis Information Group The Chassis Information Group provides information about the type or types of chassis in your system as well as information about the light emitting diode LED indicators and settings for devices on each chassis Information is also available about the current date and time displayed on the chassis intrusion warnings watchdog timer systems management basic input output system SMBIOS and so on Chassis Information Group Tables The following management information base MIB tables define the objects in the Chassis Information Group e Chassis Information Table e UUID Table e POST Log Table e Event Log Table System BIOS Table e Firmware Table e Intrusion Table e Baseboard Table Chassis Information Table The following object sets up the Chassis Information Table Name chassisInformationTable Object ID 1 3 6 1 4 1 674 10892 1 300 10 Description Defines the chassis information table Syntax SEQUENCE OF ChassisInformationTableEntry Access Not accessible Chassis Information Group 71 Chassis Information Table Entry Name chassisInformationTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 Description Defines the chassis information table entry Syntax ChassisInformationTableEntry Access Not
484. stem severity Event Log detailed log with info is in Severity drsAlert Normal Message varbind BMC Traps The BMC monitors the system for critical events by communicating with various sensors on the system board and by sending alerts and log events when certain parameters exceed their preset thresholds All of the traps documented in this section belong to the MIB enterprise identified by OID 1 3 6 1 4 1 3183 1 1 1 Table 26 20 BMC Traps TrapID Description Severity 262402 Generic Critical Fan Failure Critical 262530 Generic Critical Fan Failure Cleared Informational 131330 Under Voltage Problem Lower Critical Critical going low 131458 Under Voltage Problem Cleared Informational 131841 Generic Critical Voltage Problem Critical 131840 Generic Critical Voltage Problem Informational Cleared 65792 Under Temperature Warning Lower non Warning critical going low Traps 731 Table 26 20 BMC Traps continued Trap ID Description Severity 65920 Under Temperature Warning Cleared Informational 65794 Under Temperature Problem Lower Critical Critical going low 65922 Under Temperature Problem Cleared Informational 65799 Over Temperature warning Upper non Minor critical going high 65927 Over Temperature warning Cleared Informational 6580
485. stination Syntax DellObjectRange Access Read only Remote SNMP Trap State Capabilities Name remoteSNMPTrapStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 4 Description Defines the state capabilities of this remote access SNMP trap destination Syntax DellRemoteSNMPTrapStateCapabilities See Table 19 18 Access Read only Remote SNMP Trap State Settings Name remoteSNMPTrapStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 5 Description Defines the state settings of this remote access SNMP trap destination Syntax DellRemoteSNMPTrapStateSettings See Table 19 19 Access Read write Remote SNMP Trap Status Name remoteSNMPTrapStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 6 Description Defines the status of this remote access SNMP trap destination Syntax DellStatus Access Read only Remote Access Group 487 Remote SNMP Trap Destination IP Address Name remoteSNMPTrapDestinationIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 7 Description Defines the IP address of this remote access SNMP trap destination Syntax IpAddress Access Read write Remote SNMP Trap SNMP Community Name Name remoteSNMPTrapSNMPCommunityName Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 8 Description Defines the community for traps sent to this remote access SNMP trap destination Syntax DisplayString SIZE 0 31 Access Read write Remote SNMP Trap Filter DRS Events Mask Name remoteSNMPTrapFilte
486. support any authentication type including clear text for PPP dial Ou PPPAuthEncryptedCapable 16 The dial out destination can support encrypted passwords authentication type for PPP dial Ou PPPAuthMschapCapable 32 The dial out destination can support MSCHAP authentication type for PPP 514 Remote Access Group Table 19 28 Remote Dial Out State Settings Variable Name De 1 1RemoteDialOutStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The dial out destination has no state settings unknown 1 The dial out destination state ettings are unknown n enabled 2 The dial out destination is disabled or enabled notReady 4 The dial out destination is in the not ready state dial Out PP PAut hAnyEnabled 8 The dial out destination accepts any authentication type including clear text for PPP dial Out PP PAut EncryptedEnabled 16 The dial out destination uses only encrypted passwords authentication type for PPP dial Out PP PAut schapEnabled 32 The dial out destination uses only MSCHAP authentication type for PPP Remote Access Group 515 516 Remote Access Group Cluster Group Clustering combines multiple systems in such a way that they provide services a single system cannot Cluster
487. supported by the parallel port Syntax DellBoolean Access Read only Serial Port Table Name serialPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 80 Description Defines the Serial Port Table Syntax IntegerSerialPortTableEntry Access Not accessible Serial Port Table Entry Name serialPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 Description Defines the Serial Port Table entry Syntax SerialPortTableEntry Access Not accessible Index serialPortchassisIndex serialPortIndex 246 Port Group Serial Port Chassis Index Name serialPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Serial Port Index Name serialPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 2 Description Defines the index of the serial ports in this chassis Syntax DellObjectRange Access Read only Serial Port State Capabilities Name serialPortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 3 Description Defines the capabilities of the serial port Syntax DellStateCapabilities Access Read only Serial Port State Settings Name serialPortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 4 Description Defines the state and settings of the serial port Syntax DellStateSettings Access Read write Port Group 247 Serial Port Status Name serialPortStatus Object ID 1 3 6 1 4 1 674
488. sure Management Module Connection Enclosure Name Name enclosureManagementModuleConnectionEnclosureName Object ID 1 3 6 1 4 1 674 10893 1 20 130 14 1 4 Description Identifies the name of the enclosure as represented in Storage Management to which this enclosure memory module belongs Syntax DisplayString Access Read only Enclosure Management Module Connection Enclosure Number Name enclosureManagementModuleConnectionEnclosure Number Object ID 1 3 6 1 4 1 674 10893 1 20 130 14 1 5 Description Identifies the instance number of the enclosure in the enclosureTable to which this enclosure memory module belongs Syntax Integer Access Read only 632 Storage Management Group Battery Table This table describes available properties for each controller battery on the managed system The following object sets up the Battery Table Name Object ID Description batteryTable 1 3 6 1 4 1 674 10893 1 20 130 15 Defines the battery table Syntax SEQUENCE OF BatteryEntry Access Not accessible Battery Entry Name batteryEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 Description Defines the battery table entry Syntax BatteryEntry Access Not accessible Index batteryNumber Battery Number Name batteryNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 1 Description Identifies the instance number of the battery entry Syntax Integer Access Read only Storage Management Group 633 Battery Name Name
489. t Syntax DellStatus Access Read write SCSI Port Status Name sCSIPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 5 Description Defines the status of the SCSI port Syntax DellStatus Access Read only SCSI Port Security State Name sCSIPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 6 Description Syntax Access Defines the security settings of the SCSI port DellPortSecurityState Read only PortGroup 241 SCSI Port Connector Type Name sCSIPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 7 Description Defines the connector type of the SCSI port Syntax DellSCSIPortConnectorType See Table 12 6 Access Read only SCSI Port Name Name sCSIPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 8 Description Defines the name of the SCSI port Syntax DellString Access Read only SCSI Port BIOS Connector Type Name sCSIPortBlOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 9 Description Defines the BIOS connector type of the SCSI port Syntax DellGenericPortConnectorlype Access Read only Parallel Port Table Name parallelPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 70 Description Defines the Parallel Port Table Syntax IntegerParallelPort TableEntry Access Not accessible 242 Port Group Parallel Port Table Entry Name Object ID Description Syntax Access Index parallelPortTableEntry 1 3 6 1 4 1 674 10892 1 1000 70 1 Defines the Parallel Port Tabl
490. t Capabilities Name Object ID Description Syntax Access powerProfileCustomFanMgmtCapabilities 1 3 6 1 4 1 674 10892 1 600 70 1 9 Defines the custom fan power and performance management capabilities that are available for the Custom power profile DellFanPowerPerformanceManagement Type Read only Power Group 183 Power Profile Custom Fan Mgmt Setting Name powerProfileCustomFanMgmt Setting Object ID 1 3 6 1 4 1 674 10892 1 600 70 1 10 Description Defines the custom fan power and performance management setting for the Custom power profile Syntax DellFanPowerPerformanceManagement Type Access Read only Power Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 8 1 Power Supply State Capabilities Unique Variable Name De 1 1PowerSupplyStateCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The power supply s capabilities are unknown onlineCapable 2 The power supply can be disabled offline a binary 0 value or enabled online a binary 1 value notReadyCapable 4 The power supply s capabilities are not ready Table 8 2 Power Supply State Settings Unique Variable Name De 1 1PowerSupplyStateSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The power supply s capabilities are unknown onLine
491. t ID 1 3 6 1 4 1 674 10892 1 1000 70 1 7 Description Defines the connector type of the parallel port Syntax DellParallelPortConnectorType Access Read only 244 Port Group Parallel Port Name Name parallelPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 8 Description Defines the name of the parallel port Syntax DellString Access Read only Parallel Port Connector Pin Out Name parallelPortConnectorPinOut Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 9 Description Defines the pinout of the parallel port Syntax DellParallelPortConnectorPinout Access Read only Parallel Port Capabilities Unique Name parallelPortCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 10 Description Defines the capabilities of the parallel port Syntax DellParallelPortConnectorPinout Access Read only Parallel Port Base 1 0 Address Name parallelPortBaselOAddress Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 11 Description Defines the Base Input Output I O address of the parallel port Syntax DellUnsigned64BitRange Access Read only PortGroup 245 Parallel Port IRO Level Name parallelPortIRQLevel Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 12 Description Defines the Interrupt Request Level IRQ of the parallel port Syntax DellUnsigned BitRange Access Read only Parallel Port DMA Support Name parallelPortDMASupport Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 13 Description Defines if direct memory access DMA is
492. t is measuring acceptable temperatures would be reported as normal When the probe begins reading temperatures that exceed limits set by the user it reports a critical status Tables This reference guide contains two types of tables tables that are used to organize and define variable values and tables that define MIB objects Readers must understand the difference between these two types of tables SNMP Tables Most of the MIB objects defined in this reference guide are organized into SNMP tables SNMP tables organize data into two dimensional structural arrays In SNMP objects that have a relationship to other objects are called columnar objects Columnar objects are objects used to form lists and tables When a MIB group is divided into one or more discrete tables the word table has a technical meaning An example is the section of this reference guide entitled Universal Unique Identifier UUID The UUID object has a type and a value that uniquely identifies an object such as a chassis The table defines all of the variables that comprise the managed object UUID Introduction 33 The following table is an example of an SNMP table The table contains variables that must occur in a definite sequence In the example table the defined variables are UUID Chassis Index UUID Index UUID Type and UUID Value Example SNMP Table UUID Table These objects comprise the Server Administrator definitions for the UUID Name uUIDTable Ob
493. t software This global status is customized for HP OpenView Other applications should refer to the agentSystemGlobalStatus entry in the globalData object group Possible values 1 Critical 2 Warning 3 Normal 4 Unknown Syntax Integer Access Read only Software Manufacturer Name softwareManufacturer Object ID 1 3 6 1 4 1 674 10893 1 20 3 Description Identifies the manufacturer of the Storage Management software Syntax DisplayString Access Read only Software Product Name softwareProduct Object ID 1 3 6 1 4 1 674 10893 1 20 4 Description Identifies product information for the Storage Management software Syntax DisplayString Access Read only 544 Storage Management Group Software Description Name softwareDescription Object ID 1 3 6 1 4 1 674 10893 1 20 5 Description Identifies the product description for the Storage Management software Syntax DisplayString Access Read only Storage Management Information Group The Storage Management Information MIB Group defines the properties that identify the Storage Management software SNMP agent Display Name Name displayName Object ID 1 3 6 1 4 1 674 10893 1 20 100 1 Description Identifies the name of this management software for display purposes Syntax DisplayString Access Read only Description Name description Object ID 1 3 6 1 4 1 674 10893 1 20 100 2 Description Provides a short description of this management software Syntax DisplayString Ac
494. t something significant has occurred This is analogous to a pager receiving an important message except that the SNMP trap frequently contains all the information needed to diagnose a fault Two drawbacks to SNMP traps are that they are sent using UDP which is not a guaranteed delivery mechanism and that they are not acknowledged by the receiver An SNMP trap message contains the trap s enterprise OID the agent IP address a generic trap ID the specific trap ID a time stamp and zero or more variable bindings varbinds The combination of an enterprise OID and a specific trap ID uniquely identifies each Server Administrator defined trap A varbind consists of an OID and its value and provides additional information about the trap In order for a management system to receive SNMP traps from a managed system the node must be configured to send traps to the management system Trap destination configuration is dependent on the operating system When this configuration is done a management application on the management system can wait for traps and act on them when received For a list of traps supported by the server administrator SNMP subagent see Traps 42 Introduction Instrumentation MIB Version Group The Instrumentation Management Information Base MIB Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software The mIBMajorVersionNumber mIBMi
495. ta Value unknown 1 NIF Wakeup on LAN state is unknown enabled 2 NIF Wakeup on LAN is enabled addInCard 4 NIF Wakeup on LAN is by option card onBoard 8 NIF Wakeup on LAN is by integrated NIF addInCardOrOnBoard 12 NIF Wakeup on LAN is by option card or integrated NIE 410 BIOS Setup Control Group Table 16 5 Boot Sequence Control Capabilities Unique Variable Name De 1 1Boot SequenceControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value boot SequenceUnknown 1 Boot sequence capabilities are unknown bootFromDisketteFirstCapable Setup BIOS can boot from a diskette 2 first bootFromhardDriveFirstCapable Setup BIOS can boot from an IDE hard 4 drive first bootFromDisketteORHardDrive Setup BIOS can boot from a diskette or FirstCapable 6 an IDE hard drive first bootFromDeviceListCapable 8 Setup BIOS can boot from a device list bootFromCDROMFirstCapable 16 Setup BIOS can boot from a CD first allFirstCapable 30 Setup BIOS can boot by any of the preceding methods first Table 16 6 Boot Sequence Control Settings Unique Variable Name De 1 1Boot SequenceControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value bootSequenceUnknown 1 Boot sequence state is unknown bootFromDisketteFirst 2 Setup BIOS is set to boot by diskette first bo
496. tate of the parallel port DellParallelPortControlSettingsUnique See Table 16 13 Read only Parallel Port Control Status Name Object ID Description Syntax Access parallelPortControlStatus 1 3 6 1 4 1 674 10892 1 1400 30 1 5 Defines the status of the parallel port DellStatus Read only Parallel Port Control Name Name Object ID Description Syntax Access parallelPortControlName 1 3 6 1 4 1 674 10892 1 1400 30 1 6 Defines the setup BIOS name of the parallel port DellString Read only BIOS Setup Control Group 397 Parallel Port Control Mode Capabilities Unique Name Object ID Description Syntax Access parallelPortControlModeCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1400 30 1 7 Defines the mode capabilities of the parallel port DellParallelPortControlModeCapabilitiesUnique See Table 16 14 Read only Parallel Port Control Mode Settings Unique Name Object ID Description Syntax Access parallelPortControlModeSettingsUnique 1 3 6 1 4 1 674 10892 1 1400 30 1 8 Defines the mode settings of the parallel port DellParallelPortControlModeSettingsUnique See Table 16 14 Read write Serial Port Control Table Name Object ID Description Syntax Access serialPortControlTable 1 3 6 1 4 1 674 10892 1 1400 40 Defines the Serial Port Control Table Serial PortControl TableEntry Not accessible Serial Port Control Table Entry Name Object ID Description Syntax A
497. tatus of the object is failed Variable Name DellDate Data Type Del 1Unsigned64BitRange OCTET STRING SIZE 8 The DellDate definition is required because SNMP V1 does not support 64 bit ranges The information sent back by this subagent will have the most significant byte of the information as the first byte For example the hex address 0x1029384754657687 will be sent as hex 0001 0000 0010 1001 0011 1000 0100 0111 Byte 1 Byte2 Byte3 Byte 4 Standard Data Type Definitions 747 Full Dates Variable Name De 1 1DateName Data Type DisplayString DisplayString SIZE 25 Full dates are defined in the ASCH format yyyyMMddhhmmss uuuuuu fff or yyyyMMddhhmmss uuuuuu fff where yyyy is the year MM is the month dd is the day hh are the hours mm are the minutes and ss are the seconds uuuuuu is the number of microseconds and fff or fff is the offset from UTC in minutes For example Friday October 31 2001 at 6 05 19 PM CST would be represented as 20011031180519 000000 360 The values are zero padded and if a valid value for a field is not deliverable each character in the field will be replaced with an asterisk character 748 Standard Data Type Definitions SNMP Sample Output This sample output from the Simple Network Management Protocol SNMP covers the first four groups of the Instrumentation management information base MIB Values are shown for each object identifier OID in the Instrumentation MI
498. tax DisplayString SIZE 0 1024 Access Read only BMC IPv6 URL Name Name bmcIPv6URLName Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 13 Description Defines the IPv6 URL for the BMC The URL is not present on all systems Syntax DisplayString SIZE 0 1024 Access Read only Baseboard Management Controller Serial Interface Table Name bmcSerialInterfaceTable Object ID 1 3 6 1 4 1 674 10892 1 1900 20 Description Defines the BMC Serial Interface Table Syntax SEQUENCE OF BmcSeriallnterfaceTableEntry Access Not accessible Baseboard Management Controller Group 525 BMC Serial Interface Table Entry Name bmcSerialInterfaceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 Description Defines the BMC Serial Interface Table Entry Syntax BmcSeriallnterfaceTableEntry Access Not accessible Index bmcSeriallnterfaceChassisIndex bmcSerialInterfaceB3MClIndex bmcSerialInterfaceIndex BMC Serial Interface Chassis Index Name bmcSerialInterfaceChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 1 Description Defines the index one based of the associated chassis Syntax DellObjectRange Access Read only BMC Serial Interface BMC Index Name bmcSerialInterfaceBMCIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 2 Description Defines the index one based of the associated BMC Syntax DellObjectRange Access Read only BMC Serial Interface Index Name bmcSerialInterfaceIndex Object ID 1 3 6 1 4 1 674 108
499. te Remote User Admin Pager Modem Port Name remot eUserAdminPagerModemPort Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 26 Description Defines the port for the pager modem for this remote access user Syntax DellUnsigned32BitRange Access Read write Remote User Admin E Mail Address Name Name remot eUserAdminEmailAddressName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 27 Description Defines the e mail address for this remote access user Syntax DisplayString SIZE 0 63 Access Read write Remote User Admin E Mail Custom Message Name Name remot eUserAdminEmailCustomMessageName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 28 Description Defines the e mail message to send to this remote access user Syntax DisplayString SIZE 0 31 Access Read write 484 Remote Access Group Remote User Admin Control Capabilities Name Object ID Description Syntax Access remoteUserAdminControlCapabilities 1 3 6 1 4 1 674 10892 1 1700 20 1 29 Defines the control capabilities for this remote access user DellRemoteUserAdminControlCapabilities See Table 19 14 Read only Remote User Admin Control Settings Name Object ID Description Syntax Access remoteUserAdminControlSettings 1 3 6 1 4 1 674 10892 1 1700 20 1 30 Defines the control settings for this remote access user DellRemoteUserAdminControlSettings See Table 19 15 Read write Remote User Admin User Type Name remot eUserAdminUserType Object I
500. te access hardware Syntax DellRemoteAccessControlSettings See Table 19 3 Access Read write Remote Access Monitor Capabilities Name remoteAccessMonitorCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 12 Description Defines the monitor capabilities of the remote access hardware Syntax DellRemoteAccessMonitorCapabilities See Table 19 4 Access Read only Remote Access Monitor Settings Name remoteAccessMonitorSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 13 Description Defines the monitor settings of the remote access hardware Syntax DellRemoteAccessMonitorSettings See Table 19 5 Access Read write Remote Access Local Area Network LAN Capabilities Name remoteAccessLANCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 14 Description Defines the LAN capabilities of the remote access hardware Syntax DellRemoteAccessLANCapabilities See Table 19 6 Access Read only Remote Access Group 471 Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 15 Description Defines the LAN settings of the remote access hardware Syntax DellRemoteAccessLANSettings See Table 19 7 Access Read write Remote Access Host Capabilities Name remoteAccessHostCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 16 Description Defines the host capabilities of the remote access hardware Syntax DellRemoteAccessHostCapabilities See Table 19 8 Access Read only
501. te of the octet string represents the state of the specific memory device The first byte returned represents the state of the first memory device the second byte returned represents the status of the second memory device and so on The bytes have the same definition type as DellStateSettings Syntax OCTET STRING SIZE 1 128 Access Read only System State Memory Device Status Combined Name systemStateMemoryDeviceStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 27 Description Defines the status of all memory devices in this chassis Syntax DellStatus Access Read only System State Memory Device Status Details Name systemStateMemoryDeviceStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 28 Description Defines the status of all memory devices in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific memory device The first byte returned represents the status of the first memory device the second byte returned represents the status of the second memory device and so on The bytes have the same definition type as DellStatus Syntax OCTET STRING SIZE 1 128 Access Read only 60 System State Group System State Chassis Intrusion State Details Name Object ID Description Syntax Access systemStateChassisIntrusionStateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 29 Defines the intrusion state of all intrusion detection d
502. teSettingsUnique 1 3 6 1 4 1 674 10892 1 300 40 1 4 Defines the state settings for the object that is writing the event log DellStateSettingsLogUnique Read write Chassis Information Group 89 Event Log Record Name event LogRecord Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 5 Description Defines the data for the specified chassis and log record index in the event log being returned Syntax DisplayString SIZE 0 1024 Access Read only Event Log Format Name event LogFormat Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 6 Description Defines the format of the event log Syntax DellLogFormat See Table 5 1 Access Read only Event Log Severity Status Name eventLogSeverityStatus Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 7 Description Defines the severity of the event log record Syntax DellStatus Access Read only Status Mandatory Event Log Date Name Name event LogDateName Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 8 Description Defines the date and time of the event log record Syntax DellDateName Access Read only Status Mandatory 90 Chassis Information Group System BIOS Table This table lists objects that define the system s basic input output system BIOS Name Object ID Description Syntax Access systemBIOSTable 1 3 6 1 4 1 674 10892 1 300 50 Defines the System BIOS Table SEQUENCE OF SystemBIOSTableEntry Not accessible System BIOS Table Entry Name systemBIOSTableEntr
503. ted 5 The ownership code is rented of fOfLease 6 The ownership code is off of lease transfer 7 The ownership code is transfer 458 Cost of Ownership Group Table 18 2 COO Hour Day Duration Type Variable Name Del 1CooHourDayDurationType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Duration time type is unknown hours 2 Duration time type is in hours days 3 Duration time type is in days Table 18 3 COO Day Month Duration Type Variable Name Del 1CooDayMonthDurationType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Duration time type is unknown days 3 Duration time type is in days months 4 Duration time type is in months Table 18 4 COO Month Year Duration Type Variable Name Del 1CooMonthYearDurationType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Duration time type is unknown months 4 Duration time type is in months years 5 Duration time type is in years Cost of Ownership Group 459 460 Cost of Ownership Group Remote Access Group The Remote Access Group provides information about the remote access hardware that may be present in your system In addition to providing general information about the capabilities and settings of the remote access hardware this group provides information about administrative users SNMP trap d
504. ted in Storage Management Syntax DisplayString Access Read only Controller CO Port 1 World Wide Name Name controllerC0OPort1WWN Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 34 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Storage Management Group 563 Controller C1 Port 1 World Wide Name Name controllerC1Port1WWN Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 35 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 36 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller Roll Up Status Name controllerRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 37 Description Indicates severity of the controller state This is the combined status of the controller and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 564 Storage Management Group Controller Component Status Name Object ID Description Syntax Access controllerComponentStatus 1 3 6 1 4 1 674 10893 1 20 130 1 1 38 Indicates the status of the controller itself without the propagati
505. teger Access Read only Temperature Probe Connection Enclosure Name Name temperatureConnectionEnclosureName Object ID 1 3 6 1 4 1 674 10893 1 20 130 12 1 4 Description Identifies the name of the enclosure as represented in Storage Management to which this temperature probe belongs Syntax DisplayString Access Read only 624 Storage Management Group Temperature Probe Connection Enclosure Number Name Object ID Description Syntax Access temperatureConnectionEnclosureNumber 1 3 6 1 4 1 674 10893 1 20 130 12 1 5 Identifies the instance number of the enclosure in the enclosureTable to which this temperature probe belongs Integer Read only Enclosure Management Module Table This table describes available properties for each enclosure management module on the managed system The following object sets up the Enclosure Management Module Table Name Object ID Description Syntax Access enclosureManagementModuleTable 1 3 6 1 4 1 674 10893 1 20 130 13 Defines the enclosure management module table SEQUENCE OF EnclosureManagementModuleEntry Not accessible Enclosure Management Module Entry Name Object ID Description Syntax Access Index EnclosureManagementModuleEntry 1 3 6 1 4 1 674 10893 1 20 130 13 1 Defines the enclosure management module table entry EnclosureManagementModuleEntry Not accessible enclosureManagementModuleNumber Storage Management Group 625
506. tet String Access Read only Device Sub Vendor ID Name deviceSubVendorID Object ID 1 3 6 1 4 1 674 10899 1 5 1 7 Description Provides additional vendor identification Syntax Octet String Access Read only Application Group NOTE Dell updateable components such as Basic input output system BIOS and FirmWare FW are considered applications For example the following would be returned for system BIOS Application DisplayString BIOS Application Version A10 The Application Group defines information about the applications discovered on the system during an inventory scan Identifying information includes the application type the application version and the application description 660 Change Management Group Application Group Table The following object sets up the Application Group Table Name Object ID Description Syntax Access Application Entry Name Object ID Description Syntax Access applicationTable 1 3 6 1 4 1 674 10899 1 6 Defines a table of application information for the system SEQUENCE OF ApplicationEntry Not accessible applicationEntry 1 3 6 1 4 1 674 10899 1 6 1 Defines an application entry ApplicationEntry Read only Application Index Name Object ID Description Syntax Access applicationIndex 1 3 6 1 4 1 674 10899 1 6 1 1 Defines the unique index for this application Unsigned 16BitRange Read only Application Device Index Name Object ID
507. th 1 3 6 1 4 1 674 10892 1 500 60 1 9 Defines the transfer width of the system resource DMA DellResource DMATransferWidth See Table 7 8 Read only System Resource Group 143 System Resource DMA Bus Master Name systemResourceDMABusMaster Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 10 Description Defines the bus mastering capabilities of the system resource DMA Syntax DellResource DMABusMaster See Table 7 7 Access Read only System Resource Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 7 1 System Resource Map Type Variable Name De11SystemResourceMapType Data Type Integer Possible Data Values Meaning of Data Value other 1 The system resource map type is not one of the following unknown 2 The system resource map type is unknown not known or not monitored typeOne 3 The system resource map is type one Table 7 2 Resource Owner Interface Type Variable Name De 1 1ResourceOwnerInterfaceTyp Data Type Integer Possible Data Values Meaning of Data Value typelIsOther 1 The interface type is not one of the following typelsUnknown 2 The interface type is unknown typeIsInternal 3 The interface type is internal typeIsISA 4 The interface type is an Industry Standard Architecture ISA bus 144 System Resource Group Table 7 2 Resource Owner Interface Typ
508. the capabilities of the memory device port Syntax DellStateCapabilities Access Read only Memory Device Port State Settings Name memoryDevicePortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 4 Description Defines the state and settings of the memory device port Syntax DellStateSettings Access Read write Memory Device Port Status Name memoryDevicePortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 5 Description Defines the status of the memory device port Syntax DellStatus Access Read only Memory Device Port Security State Name memoryDevicePortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 6 Description Defines the security settings of the memory device port Syntax DellPortSecurityState Access Read only PortGroup 235 Memory Device Port Connector Type Name memoryDevicePortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 7 Description Defines the connector type of the memory device port Syntax DellMemoryDevicePortConnectorType See Table 12 4 Access Read only Memory Device Port Name Name memoryDevicePortName Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 8 Description Defines the name of the memory device port Syntax DellString Access Read only Memory Device Port BIOS Connector Type Name memoryDevicePortBlOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 9 Description Defines the BIOS connector type of the memory device port Syntax DellGenericPort
509. the gateway associated with the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read write Remote Access Personal Computer Memory Card International Association PCMCIA Info Name Name remoteAccessPCMCIAInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 28 Description Defines the information for the PCMCIA device used by the remote access hardware Syntax DisplayString SIZE 0 63 Access Read only Remote Access Group 465 Remote Access Miscellaneous Information Name Name remoteAccessMiscInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 29 Description Defines the miscellaneous information for the remote access hardware Syntax DisplayString SIZE 0 63 Access Read write Remote Access NIC Current IP Address Name remoteAccessNICCurrent IPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read only Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 31 Description Defines the netmask currently being used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read only Remote Access NIC Current Gateway Address Name remoteAccessNICCurrentGatewayAddress Object ID 1 3 6 1 4 1 674
510. the reading of the processor device status probe DellProcessorDeviceStatusReading Read only Processor Device Status Location Name Name Object ID Description Syntax Access processorDeviceStatusLocationName 1 3 6 1 4 1 674 10892 1 1100 32 1 7 Defines the location name of the processor device status probe DellString Read only Processor Device Status Port Index Reference Name Object ID Description Syntax Access processorDeviceStatusPort IndexReference 1 3 6 1 4 1 674 10892 1 1100 32 1 8 Defines the index one based of the associated processor port in the same chassis DellObjectRange Read only Cache Device Table Name Object ID Description Syntax Access cacheDeviceTable 1 3 6 1 4 1 674 10892 1 1100 40 Defines the Cache Device Table SEQUENCE OF CacheDeviceTableEntry Not accessible Device Group 275 Cache Device Table Entry Name Object ID Description Syntax Access Index cacheDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 40 1 Defines the Cache Device Table entry CacheDeviceTableEntry Not accessible cacheDevicechassisIndex cacheDeviceIndex Cache Device Chassis Index Name Object ID Description Syntax Access cacheDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 40 1 1 Defines the index one based of this chassis DellObjectRange Read only Cache Device Index Name Object ID Description Syntax Access cacheDeviceIndex 1 3 6 1 4 1 674 1
511. ther Inventory Collector base MIB objects and are thus not placed in a table 664 Change Management Group Product ID Display Name Name Object ID Description Syntax Access product IDDisplayName 1 3 6 1 4 1 674 10899 100 1 Defines the display name of the product DisplayString Read only Product ID Description Name product IDDescription Object ID 1 3 6 1 4 1 674 10899 100 2 Description Provides a description of the product Syntax DisplayString Access Read only Product ID Vendor Name product IDVendor Object ID 1 3 6 1 4 1 674 10899 100 3 Description Provides name of the manufacturer of the product Syntax DisplayString Access Read only Product ID Version Name Object ID Description Syntax Access product IDVersion 1 3 6 1 4 1 674 10899 100 4 Describes the version of the product DisplayString Read only Change Management Group_ _ 665 666 Product ID Build Number Name product IDBuildNumber Object ID 1 3 6 1 4 1 674 10899 100 5 Description Describes the software build number of the product Syntax DisplayString Access Read only Change Management Group Dell RAC Out of Band Group The Dell RAC Out of Band MIB contains information for both Chassis Management Controller CMC and Remote Access Controller RAC Legacy Alerting This MIB consists of information for the following groups Product Information The following MIB tables define the Dell RAC Out of Band group DRsProdu
512. tion lt Location in chassis gt Chassis Location lt Name of chassis gt Previous state was lt State gt SD card device type lt Type of SD card device gt SD card state lt State of SD card gt in the specified system detected an error The sensor location chassis location previous state and SD card device type are provided The SD card state is provided if a SD card is present in the SD card device 724 Traps RAC Traps This section describes the traps that are generated by the SNMP agent of the Remote Access Controller RAC All of the enterprise specific traps documented in this section belong to the MIB enterprise identified by OID 1 3 6 1 4 1 674 10892 2 and are sent with all of the trap variables documented in the section Traps The trap variables are sent in the order in which they are listed Table 26 18 Generic Traps Trap Name Description Severity Category Cause Supported ID by RAC Platform 0 CodeStart SNMP agent Information Status RAC power All is on or reset initializing itself l Authentic Request Critical Error SNMP All ation received request Failure with an with an invalid invalid community community name name Table 26 19 Enterprise specific Traps Trap Name Description Severity Category Cause Supported ID by RAC Platform 1001 alertDrscTest The RAC Information Status A test SNMP All TrapEvent generated trap a test generated by trap event a RAC
513. tion Defines the Baseboard Management Controller Table Syntax SEQUENCE OF BmcTableEntry Access Not accessible Baseboard Management Controller Group 521 BMC Table Entry Name bmcTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 Description Defines the Baseboard Management Controller BMC Table Entry Syntax BmcTableEntry Access Not accessible Index bmcChassisIndex bmcIndex BMC Chassis Index Name bmcChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 1 Description Defines the index one based of the associated chassis Syntax DellObjectRange Access Read only BMC Index Name bmcIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 2 Description Defines the index one based of the BMC Syntax DellObjectRange Access Read only BMC State Capabilities Name Object ID Description Syntax Access bmcStateCapabilities 1 3 6 1 4 1 674 10892 1 1900 10 1 3 Defines the state capabilities of the BMC DellStateCapabilities Read only 522 Baseboard Management Controller Group BMC State Settings Name bmcStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 4 Description Defines the state settings of the BMC Syntax DellStateSettings Access Read write BMC Status Name bmcStatus Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 5 Description Defines the status of the BMC Syntax DellStatus Access Read only BMC Display Name Name bmcDisplayName Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 6 Desc
514. tring where each byte of the octet string represents the status of a power unit The first byte returned represents the status of the first power unit and so on The bytes have the same definition type as DellStatus Syntax OCTET STRING SIZE 1 128 Access Read only System State Group 65 System State Cooling Unit Status Combined Name systemStateCoolingUnitStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 44 Description Defines the combined status of all cooling units of this chassis Syntax DellStatus Access Read only System State Cooling Unit Status List Name systemStateCoolingUnitStatusList Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 45 Description Lists the status of each cooling unit of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a cooling unit The first byte returned represents the status of the first cooling unit and so on The bytes have the same definition type as DellStatus Syntax OCTET STRING SIZE 1 128 Access Read only System State AC Power Switch Status Combined Name systemStateACPowerSwitchStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 46 Description Defines the combined status of all AC power switches of this chassis Syntax DellStatus Access Read only 66 System State Group System State AC Power Switch Status List Name Object ID Description Syntax Access systemStateACPowerS
515. troller Serial Interface Table 525 Baseboard Management Controller LAN Interface Table 529 10 Contents Baseboard Management Controller Group Variable Values 533 22 Field Replaceable Unit Group 537 Field Replaceable Unit Group Tables 537 Field Replaceable Unit Table 537 FRU Group Variable Values 541 23 Storage Management Group 543 Storage Management Group 543 Storage Management Information Group 545 Global DataGroup 546 Physical DevicesGroup 552 Controller Table 553 Channel Tables 570 Enclosure Table 575 Array Disk Table 585 Array Disk Enclosure Connection Table 597 Array Disk Channel Connection Table 600 Fan Table aed aad Fa WES L eB 603 Fan Connection Table 609 Power Supply Table 611 Power Supply Connection Table 616 Temperature Probe Table 618 Temperature Probe Connection Table 623 Enclosure Management Module Table 625 Enclosure Management Module ConnectionTable 630 BatteryTable 633 Battery Connection Table 639 Contents 11 Logical Devices Group 641 Virtual Disk Table 641 Array Disk Logical Connection
516. ttings 1 3 6 1 4 1 674 10892 1 1300 20 1 4 Defines the state of the memory array mapped address DellStateSettings Read write MemoryGroup 365 Physical Memory Array Mapped Status Name Object ID Description Syntax Access physicalMemoryArrayMappedStatus 1 3 6 1 4 1 674 10892 1 1300 20 1 5 Defines the status of the memory array mapped address DellStatus Read only Physical Memory Array Index Reference Name Object ID Description Syntax Access physicalMemoryArrayIndexReference 1 3 6 1 4 1 674 10892 1 1300 20 1 6 Defines the index to the associated physical memory array in this chassis DellObjectRange Read only Physical Memory Array Mapped Starting Address Name Object ID Description Syntax Access physicalMemoryArrayMappedStartingAddress 1 3 6 1 4 1 674 10892 1 1300 20 1 7 Defines the physical starting address in KB of the memory array mapped address DellUnsigned64BitRange Read only Physical Memory Array Mapped Ending Address Name Object ID Description Syntax Access 366 physicalMemoryArrayMappedEndingAddress 1 3 6 1 4 1 674 10892 1 1300 20 1 8 Defines the physical ending address in KB of the memory array mapped address DellUnsigned64BitRange Read only Memory Group Physical Memory Array Mapped Partition Width Name Object ID Description Syntax Access physicalMemoryArrayMappedPartitionWidth 1 3 6 1 4 1 674 10892 1 1300 20 1 9 Define
517. ture dial InDHC PCapable 32 The dial up functionality can support using DHCP to obtain an IP address for the dial in feature dial InAut hAnyCapable 64 The dial up functionality can support any authentication type including clear text for the dial in feature dial InAut EncryptedCapable 128 The dial up functionality can support encrypted passwords CHAP authentication for the dial in feature dial TInAut hMschapCapable 256 The dial up functionality can support MSCHAP authentication type for the dial in feature Table 19 23 Remote Dial Up State Settings Variable Name De 1 1RemoteDialUpStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The dial up functionality has no state settings unknown 1 The dial up functionality state settings are unknown enabled 2 The dial up functionality is enabled notReadyCapable 4 The dial up functionality is in the not ready state diallInk Dy nabled 8 The dial up functionality dial in feature is enabled dialou Enabled 16 The dial up functionality dial out feature is enabled Remote Access Group 511 Table 19 23 Remote Dial Up State Settings continued Variable Name De 1 1RemoteDialUpStateSettings Data Type Integer Possible Data Values Meaning of Data Value dialInD
518. tureProbeEntry Access Not accessible Index TemperatureProbeNumber Temperature Probe Number Name temperatureProbeNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 1 Description Identifies the instance number of the temperature probe entry Syntax Integer Access Read only 618 Storage Management Group Temperature Probe Name Name Object ID Description Syntax Access temperatureProbeNam 1 3 6 1 4 1 674 10893 1 20 130 11 1 2 Identifies the temperature probe s name as represented in Storage Management DisplayString Read only Temperature Probe Vendor Name Object ID Description Syntax Access temperatureProbeVendor 1 3 6 1 4 1 674 10893 1 20 130 11 1 3 Identifies the temperature probe s re seller s name DisplayString Read only Temperature Probe State Name Object ID Description Syntax Access temperatureProbeStat 1 3 6 1 4 1 674 10893 1 20 130 11 1 4 Identifies the current state of the temperature probe Possible states 0 Unknown 1 Ready 2 Failed Minimum Failure Threshold Exceeded Maximum Failure Threshold Exceeded 4 Offline 6 Degraded Minimum Warning Threshold Exceeded Maximum Warning Threshold Exceeded 9 Inactive 21 Missing Integer Read only Storage Management Group 619 Temperature Probe Severity Name temperatureProbeSeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 5 Description This entry is obsolete for Stora
519. ue 1 3 6 1 4 1 674 10892 1 300 10 1 25 Defines the readings and settings of the LED control hardware in the chassis DellLEDControlSettings See Table 5 6 Read write Chassis Hard Drive HD Fault Clear Control Capabilities Name Object ID Description Syntax Access chassisHDFaultClearControlCapabilities 1 3 6 1 4 1 674 10892 1 300 10 1 26 Specifies whether the chassis allows reset of the chassis hard drive fault LED DellHDFaultLEDControlCapabilities See Table 5 7 Read only Chassis HD Fault Clear Control Settings Name Object ID Description Syntax Access chassisHDFaultClearControlSettings 1 3 6 1 4 1 674 10892 1 300 10 1 27 Allows reset of the chassis hard drive fault LED DellHDFaultLEDControlSettings See Table 5 8 Read write 78 Chassis Information Group Chassis Identify Flash Control Capabilities Name Object ID Description Syntax Access chassisIdentifyFlashControlCapabilities 1 3 6 1 4 1 674 10892 1 300 10 1 28 Specifies whether the chassis front panel LED can be set to flash DellChassisIdentifyControlCapabilities See Table 5 9 Read only Chassis Identify Flash Control Settings Name Object ID Description Syntax Access chassisIdentifyFlashControlSettings 1 3 6 1 4 1 674 10892 1 300 10 1 29 Causes the chassis front panel LED to flash DellChassisIdentifyControlSettings See Table 5 10 Read write Chassis Lock Present Name Object ID Description Synt
520. ues 424 18 Cost of Ownership Group 427 Cost of Ownership Group Tables 427 Cost of Ownership Table onnaa aaa 427 COO Service Contract Table 438 COO CostEventLogTable 440 COO Warranty Table 442 COO Lease Information Table 444 COO Schedule Number Table 447 COO Options Table 448 COO Maintenance Table 450 COO RepairTable 452 Contents COO Support Information Table 454 COO Trouble Ticket Table 456 Cost of Ownership Variable Values 458 19 Remote Access Group 461 DRAC4andDRAC5 461 Remote Access Table 461 DRAG Woe oe BA ee hae Se Se SoS 467 Remote Access Table 468 Remote User Administration Table 477 Remote SNMP Trap Table 485 Remote Dial Up Table 490 Remote User Dial In Configuration Table 494 Remote Dial OutTable 497 Remote Access Variable Values 500 20 Cluster Group 45 24 30200e852 ache es 517 Cluster Group 4 517 Cl ster Table i i o e gach Gh A Pea E 517 Cluster Group Variable Values 520 21 Baseboard Management Controller Group 521 Baseboard Management Controller Group Tables 521 Baseboard Management Controller Table 521 Baseboard Management Con
521. umber of the array disk in this logical connection Syntax Integer Access Read only Array Disk Logical Connection Virtual Disk Name Name arrayDiskLogicalConnectionVirtualDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 4 Description Identifies the name of the virtual disk to which this array disk belongs Syntax DisplayString Access Read only Array Disk Logical Connection Virtual Disk Number Name arrayDiskLogicalConnectionVirtualDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 5 Description Identifies the instance number of the virtual disk to which this array disk belongs Syntax Integer Access Read only Array Disk Logical Connection Disk Name Name arrayDiskLogicalConnectionDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 6 Description Identifies the name of the disk group to which this array disk belongs This property is currently not supported Syntax DisplayString Access Read only 652 Storage Management Group Array Disk Logical Connection Disk Number Name arrayDiskLogicalConnectionDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 7 Description Identifies the instance number of the disk group to which this array disk belongs This property is currently not supported Syntax Integer Access Read only Storage Management Event Group The Storage Management Event Group defines the properties that will be sent with SNMP traps Message ID Event Name messageIDEvent
522. unknown logReset 2 The remote access hardware will reset its i ntegrated logs hardReset 4 a The remote access hardware will perform hard reset softReset 8 The remote access hardware will perform a soft reset Remote Access Group 501 Table 19 3 Remote Access Control Settings continued Variable Name De 1 1RemoteAccessControlSettings Data Type Integer Possible Data Values Meaning of Data Value gracefulReset 16 The remote access hardware will gracefully shut down and perform a soft reset defaultConfigReset 32 The remote access hardware will reset to its default settings shutdown 64 The remote access hardware will shut down Table 19 4 Remote Access Monitor Capabilities Variable Name De 1 1RemoteAccessMonitorCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no monitor capabilities unknownCapabilities 1 The remote access hardware monitor capabilities are unknown extPwrSupplyMonitorIfConn The remote access hardware can be set to ectedCapable 2 monitor the external power supply if connected extPwrSupplyMonitorAlways The remote access hardware can be set to EnabledCapable 4 always monitor the external power supply 502 Remote Access Group Table 19 5 Remote Access Monitor Settings Variable Name De 1 1RemoteAccessMonitorS
523. upply systemSlotCanProvide3Point 3Volts 256 The system slot can provide a 3 3 V supply systemSlotCanSignallfShared 512 The system slot s opening if shared with another slot can be detected systemSlotCanSupportCard1l6 1024 The system slot can support PC Card 16 systemSlotCanSupportCardBus 2048 The system slot can support CardBus systemSlotCanSupport Zoomvid eo 4096 The system slot can support Zoom Video systemSlotCanSupportModem RingResume 8192 The system slot can support modem ring resume systemSlotCanSupportPMESig nal 16384 The system slot can support Power Management Enable PME signal canSupportAllSlotCapabilit ies 32640 The system slot can support all slot capabilities 350 Slot Group Table 14 2 System Slot State Settings Variable Name De11SystemSlotStateSettings Data Type Integer Possible Data Values Meaning of Data Value systemSlotHotPlugIsUnknown 1 The system slot s capabilities are unknown systemSlotHotPlugIsHotPluggable 2 The system slot supports hot plug systemSlotHotPlugIsPoweredOn 4 The system slot power and corresponding LED can be powered on systemSlotHotPlugIsAtAttention 8 The system slot attention state and corresponding LED can be set systemSlotHotPlugIsHotPluggable 2 The system slot supports hot plug systemSlotHotPlugIsPow
524. urrent state lt State gt A current sensor on the power supply for the specified system returned to a valid range after crossing a failure threshold The sensor location chassis location previous state and current sensor value are provided Amperage Probe Warning 1203 Current sensor detected a warning value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Current sensor value in Amps lt Reading gt If sensor type is discrete Discrete current state lt State gt 708 Traps A current sensor on the power supply for the specified system exceeded its warning threshold The sensor location chassis location previous state and current sensor value are provided Table 26 6 Amperage Probe Traps continued Trap ID Description Severity Cause Amperage Probe Failure 1204 Current sensor detected a Error A current sensor on the failure value power supply for the Sensor location lt Location aise ae in ochassis gt exceeded its failure threshold The sensor Chassis location lt Name of location chassis chassis gt location previous state Previous state was lt State gt and current sensor value are provided If sensor type is not P discret Current sensor value in Amps lt Reading gt If sensor type is discrete Discrete current state lt State gt Am
525. us Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 6 Description Defines the status of the remote access hardware Syntax DellStatus Access Read only Remote Access Group _ 469 Remote Access Product Info Name Name remoteAccessProduct InfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 7 Description Defines the name of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 63 Access Read only Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 8 Description Defines the description of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 255 Access Read only Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 9 Description Defines the version of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 63 Access Read only Remote Access Control Capabilities Name remoteAccessControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 10 Description Defines the control capabilities of the remote access hardware Syntax DellRemoteAccessControlCapabilities See Table 19 2 Access Read only 470 Remote Access Group Remote Access Control Settings Name remoteAccessControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 11 Description Defines the control settings of the remo
526. vel is tertiary Device Group 331 Table 13 9 Cache Device Write Policy Variable Name De 1 1CacheDeviceWritePolicy Data Type Integer Possible Data Values Meaning of Data Value deviceWritePolicyIsOther 1 Device write policy is not one of the following deviceWritePolicyIsUnknown 2 Device write policy is unknown deviceWritePolicylIsWriteBack 3 Device write policy is write back deviceWritePolicyIsWriteThrough 4 Device write policy is write through deviceWritePolicyIsVariesByAddress 5 Device write policy varies by address deviceWritePolicyIsDeterminedByI0 6 Device write policy is determined by I O query Table 13 10 Cache Device Status State Variable Name De 1 1CacheDeviceStatusState Data Type Integer Possible Data Values Meaning of Data Value other 1 Device state is not one of the following unknown 2 Device state is unknown enabled 3 Device is enabled userDisabled 4 Device is disabled by the user biosDisabled 5 Device basic input output system BIOS is disabled 332 Device Group Table 13 11 Cache Device ECC Type Variable Name De11PointingDeviceType Data Type Integer Possible Data Values Meaning of Data Value deviceTypelIsOther 1 Device type is not one of the following deviceTypelIsUnknown 2 Device type is unknown deviceTypelIsAMouse 3 Device type is a mouse
527. vice the second byte returned represents the state of the second cooling device and so on The bytes have the same definition type as DellStateSettings Syntax OCTET STRING SIZE 1 128 Access Read only System State Cooling Device Status Combined Name systemStateCoolingDeviceStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 21 Description This attribute defines the cooling device status of all cooling devices in this chassis The results is returned as a combined status value The value has the same definition type as DellStatus Syntax DellStatus Access Read only System State Cooling Device Status Details Name systemStateCoolingDeviceStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 22 Description Defines the status of all cooling devices in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific cooling device The first byte returned represents the status of the first cooling device the second byte returned represents the status of the second cooling device and so on The bytes have the same definition type as DellStatus Syntax OCTET STRING SIZE 1 128 Access Read only 58 System State Group System State Temperature State Details Name systemStateTemperatureStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 23 Description Defines the state of all temperature probes in this chassis The results are returned as a
528. vice Group Table Name Object ID Description Syntax Access Device Entry Name Object ID Description Syntax Access Device Index Name Object ID Description Syntax Access deviceTable 1 3 6 1 4 1 674 10899 1 5 Defines the Device Table SEQUENCE OF DeviceEntry Not accessible deviceEntry 1 3 6 1 4 1 674 10899 1 5 1 Defines a device entry DeviceEntry Not accessible deviceIndex 1 3 6 1 4 1 674 10899 1 5 1 1 Defines the unique index for this device Unsigned 16BitRange Read only Change Management Group Device Component ID Name deviceComponent ID Object ID 1 3 6 1 4 1 674 10899 1 5 1 2 Description Defines an optional component ID field for the device Syntax Integer Access Read only Device Display String Name deviceDisplayString Object ID 1 3 6 1 4 1 674 10899 1 5 1 3 Description Provides a displayable string that describes the device Syntax DisplayString Access Read only Device Vendor ID Name deviceVendorID Object ID 1 3 6 1 4 1 674 10899 1 5 1 4 Description Defines the ID for the vendor supplying the device Syntax Octet String Access Read only Device ID Name deviceDeviceID Object ID 1 3 6 1 4 1 674 10899 1 5 1 5 Description Defines the ID for the device Syntax Octet String Access Read only Change Management Group 659 Device Sub ID Name deviceSubID Object ID 1 3 6 1 4 1 674 10899 1 5 1 6 Description Provides additional device identification Syntax Oc
529. viceAssocia lative 11 tivityIs32WaySe tAssoc Device is 32 way Set Associative deviceAssocia lative 12 tivityIs48WaySe tAssoc Device is 8 way Set Associative deviceAssocia lative 13 tivityIs6 4WaySe tAssoc Device is 64 way Set Associative Table 13 13 Cache Device Location Variable Name De 1 1CacheDeviceLocation Data Type Integer Possible Data Values Meaning of Data Value deviceLocationIsOther 1 Device location is not one of the following deviceLocationIs Unknown 2 Device location is unknown deviceLocationIs Internal 3 Device location is internal deviceLocationIsExternal 4 Device location is external 334 Device Group Table 13 14 Cache Device Static Random Access Memory SRAM Type Variable Name De 1 1 CacheDeviceSRAMType Data Type Integer Possible Data Values Meaning of Data Value deviceSRAMTypelsOther 1 Device SRAM type is not one of the following deviceSRAMTypelsUnknown 2 Device SRAM type is unknown deviceSRAMTypeIsNonBurst 3 Device SRAM type is nonburst deviceSRAMTypelIsBurst 4 Device SRAM type is burst deviceSRAMTypelIsPipeBurst 5 Device SRAM type is pipeburst deviceSRAMTypeIsSynchronous 6 Device SRAM type is synchronous deviceSRAMTypelIsAsynchronous 7 Device SRAM type is asynchronous Table 13 15 Memory Device Type Form Factor
530. vided Chassis location lt Name of chassis gt Fan Enclosure Removal 1453 Fan enclosure removed Warning A fan enclosure has been from system removed from the specified Bouse Tweeters system The sensor Srocati n tA chassis location and chassis location are provided Chassis location lt Name of chassis gt Fan Enclosure Extended Removal 1454 Fan enclosure removed Error A fan enclosure has been from system for an removed from the specified extended amount of system for a user definable time length of time The sensor sarson Ge baat eit and ee lt Location in chassis gt o ationare provided Chassis location lt Name of chassis gt AC Power Cord Traps The AC power cord sensor monitors the presence of AC power for an AC power cord AC power cord traps provide status and warning information for power cords that are part of an AC power switch if your system supports AC switching Traps 717 Table 26 12 AC Power Cord Traps Trap ID Description Severity Cause AC Power Cord No Power Nonredundant 1501 AC power cord is not Information The AC power cord status is being monitored not being monitored This senson pinata te te occurs Lee a system s lt Location in chassis gt expecte AG Boer i i configuration is set to Chassis location nonredundant The sensor lt Name of chassis gt location and chassis location information are provided AC Power Cord Normal 1502 AC power has been Information An AC power cord that
531. wer supply sensor detects predictive failure psACLost 8 The power supply s AC power is lost acLostOrOutOfRange 16 The power supply s AC power is lost or out of range 186 Power Group Table 8 4 Power Supply Sensor State continued Variable Name De 1 1PowerSupplySensorState Data Type Integer Possible Data Values Meaning of Data Value acOutOfRangeButPresent 32 The power supply s AC power is present but it is out of range configurationError 64 The power supply sensor detects a configuration error Table 8 5 Power Supply Configuration Error Type Variable Name De 1 1PowerSupplyConfigurationErrorType Data Type Integer Possible Data Values Meaning of Data Value vendorMismatch 1 The power supply configuration error type is vendor mismatch revisionMismatch 2 The power supply configuration error type is revision mismatch processorMissing 3 The power supply configuration error type is processor missing Table 8 6 Voltage Probe Type Variable Name De11VoltageType Data Type Integer Possible Data Values Meaning of Data Value voltageProbeTypelsOther 1 The voltage probe type is not one of the following voltageProbeTypelIsUnknown 2 The voltage probe type is unknown not known or not monitored voltageProbeTypelIslPoint5Volt The voltage probe type is a 1 5 volt V 3 probe Power Group 187 188 Table 8
532. werCordTableEntry Access Not accessible Power Group 169 AC Power Cord Table Entry Name Object ID Description Syntax Access Index aCPowerCordTableEntry 1 3 6 1 4 1 674 10892 1 600 42 1 Defines the AC Power Cord Table entry ACPowerCordTableEntry Not accessible aCPowerCordchassisIndex aC PowerCordIndex AC Power Cord Chassis Index Name Object ID Description Syntax Access aCPowerCordChassisIndex 1 3 6 1 4 1 674 10892 1 600 42 1 1 Defines the index one based of the chassis containing this AC power cord DellObjectRange Read only AC Power Cord Index Name Object ID Description Syntax Access aCPowerCordIndex 1 3 6 1 4 1 674 10892 1 600 42 1 2 Defines the index one based of this AC power cord DellObjectRange Read only AC Power Cord State Capabilities Name Object ID Description Syntax Access aCPowerCordStateCapabilities 1 3 6 1 4 1 674 10892 1 600 42 1 3 Defines the capabilities of this AC power cord DellACPowerCordStateCapabilities Read only 170 Power Group AC Power Cord State Settings Name aCPowerCordStateSettings Object ID 1 3 6 1 4 1 674 10892 1 600 42 1 4 Description Defines the settings of this AC power cord Syntax DellACPowerCordStateSettings Access Read write AC Power Cord Status Name aCPowerCordStatus Object ID 1 3 6 1 4 1 674 10892 1 600 42 1 5 Description Defines the status of this AC power cord Syntax DellStatus Access Read only AC
533. witchStatusList 1 3 6 1 4 1 674 10892 1 200 10 1 47 Lists the status of each AC power switch of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of an AC power switch The first byte returned represents the status of the first AC power switch and so on The bytes have the same definition type as DellStatus OCTET STRING SIZE 1 128 Read only System State Redundant Memory Unit Status Combined Name Object ID Description Syntax Access systemStateRedundantMemoryUnitStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 48 Defines the combined status of all redundant memory units of this chassis DellStatus Read only System State Redundant Memory Unit Status List Name Object ID Description Syntax Access systemStateRedundantMemoryUnitStatusList 1 3 6 1 4 1 674 10892 1 200 10 1 49 Lists the status of each redundant memory unit of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a redundant memory unit The first byte returned represents the status of the first redundant memory unit and so on The bytes have the same definition type as DellStatus OCTET STRING SIZE 1 128 Read only System State Group 67 System State Processor Device Status Combined Name systemStateProcessorDeviceStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 50
534. xeo The processor family is Quad Core Intel n3xxx 216 Xeon processor 3xxx Series deviceFamilyIsDualCoreIntelxeo The processor family is Dual Core Intel n5xxx 218 Xeon processor 5xxx Series deviceFamilyIsQuadCoreIntelxeo The processor family is Quad Core Intel n5xxx 219 Xeon processor 5xxx Series deviceFamilyIsDualCoreIntelxeo The processor family is Dual Core Intel n7xxx 221 Xeon processor 7xxx Series Device Group 329 Table 13 6 Processor Device Family continued Variable Name De 1 1ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsQuadCoreIntelxeo The processor family is Quad Core Intel n7xxx 222 Xeon processor 7xxx Series deviceFamilyIsMultiCoreIntelXxe The processor family is Multi Core Intel on7xxx 223 Xeon processor 7xxx Series deviceFamilyIsEmbeddedAMDOpert The processor family is Embedded onQuadCore 230 AMD Opteron Quad Core deviceFamilyIsAMDPhenomTriplec The processor family is AMD Phenom ore 231 Triple Core deviceFamilyIsAMDTurionUltraDu The processor family is AMD Turion alCoreMobile 232 Ultra Dual Core mobile processor deviceFamilyIsAMDTurionDualCor The processor family is AMD Turion eMobile 233 Dual Core mobile processor deviceFamilyIsAMDAthlonDualCor The processor family is AMD Athlon e 234 Dual Core deviceFamilyIsAMDSempronSI 235 The processor family is AMD Sempron
535. y Not accessible voltageProbechassisIndex voltageProbeIndex Voltage Probe Chassis Index Name Object ID Description Syntax Access voltageProbechassisIndex 1 3 6 1 4 1 674 10892 1 600 20 1 1 Defines the index one based of this chassis DellObjectRange Read only 156 Power Group Voltage Probe Index Name Object ID Description Syntax Access voltageProbeIndex 1 3 6 1 4 1 674 10892 1 600 20 1 2 Defines the index of voltage probes in this chassis DellObjectRange Read only Voltage Probe State Capabilities Name Object ID Description Syntax Access voltageProbeStateCapabilities 1 3 6 1 4 1 674 10892 1 600 20 1 3 Defines the capabilities of the voltage probe DellStateCapabilities Read only Voltage Probe State Settings Name Object ID Description Syntax Access voltageProbeStateSettings 1 3 6 1 4 1 674 10892 1 600 20 1 4 Defines the state and settings of the voltage probe DellStateSettings Read write Voltage Probe Status Name Object ID Description Syntax Access voltageProbeStatus 1 3 6 1 4 1 674 10892 1 600 20 1 5 Defines the status of the voltage probe DellStatusProbe Read only Power Group 157 Voltage Probe Reading Name voltageProbeReading Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 6 Description Defines the value of the voltage probe reading The value is an integer representing the voltage in millivolts that the probe is reading When the value for v
536. y Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 Description Defines the System BIOS Table entry Syntax SystemBIOS TableEntry Access Not accessible Index systemB OSchassisIndex systemBIOSIndex System BIOS Chassis Index Name systemBIOSchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only System BIOS Index Name systemB1I0SIndex Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 2 Description Syntax Access Defines the index one based of the system BIOS of this object DellObjectRange Read only Chassis Information Group 91 System BIOS State Capabilities Name systemBIOSStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 3 Description Defines the capabilities of the system BIOS of this object Syntax DellStateCapabilities Access Read only System BIOS State Settings Name systemBIOSStateSettings Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 4 Description Defines the state of the system BIOS of this object Syntax DellStateSettings Access Read write System BIOS Status Name systemBlOSStatus Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 5 Description Defines the status of the system BIOS of this object Syntax DellStatus Access Read only System BIOS Size Name systemBlOSSize Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 6 Description Defines the image size of the system BIOS in kilobytes KB A zero 0
537. ysical Memory Card DellObjectRange Read only Physical Memory Card State Capabilities Name Object ID Description Syntax Access physicalMemoryCardStateCapabilities 1 3 6 1 4 1 674 10892 1 1300 60 1 3 Defines the state capabilities of the Physical Memory Card DellStateCapabilities Read only Physical Memory Card State Settings Name Object ID Description Syntax Access physicalMemoryCardStateSettings 1 3 6 1 4 1 674 10892 1 1300 60 1 4 Defines the state settings of the Physical Memory Card DellStateSettings Read write Physical Memory Card Status Name Object ID Description Syntax Access physicalMemoryCardStatus 1 3 6 1 4 1 674 10892 1 1300 60 1 5 Defines the status of the Physical Memory Card DellStatus Read only Memory Group _ 375 Physical Memory Card Name Name Object ID Description Syntax Access physicalMemoryCardName 1 3 6 1 4 1 674 10892 1 1300 60 1 6 Defines the name of the Physical Memory Card DellString Read only Physical Memory Card Total Number Sockets Access Name Object ID Description Syntax physicalMemoryCardTotalNumberSockets 1 3 6 1 4 1 674 10892 1 1300 60 1 7 Defines the total number of memory sockets available on the Physical Memory Card 2 147 483 647 indicates an unknown number of sockets DellUnsigned32BitRange Read only Physical Memory Card In Use Number Sockets Syntax Access 376 Name Object ID Description physic
538. ystem Services Device Table 309 SD Card UnitTable 311 SD Card Device Table 314 Device Group Variable Values 317 14 Slot Group 444 viacudeudivaeuawans 345 System Slot Group Table 345 System SlotTable 345 System Slot Variable Values 349 15 Memory Group 359 Physical Memory Tables 359 Physical Memory Array Table 359 Physical Memory Array Mapped Table 364 Physical Memory Configuration Table 367 Physical Memory Logging Table 369 Redundant Memory Unit Table 371 Physical Memory CardTable 374 Memory Group Variable Values 377 Contents 16 BIOS Setup Control Group 383 BIOS Group Tables 383 BIOS Setup Control Table 383 SCSI Control Table aaa aaa aaa 394 Parallel Port Control Table 396 Serial Port Control Table naaa aaa 398 USB Control Table 400 IDEControlTable 402 Diskette Control Table 404 Network Interface Control Table 406 BIOS Group Variable Values 409 17 Local Response Agent Group 419 LRAGroupTables 419 LRA Global Settings 419 LRA Global Settings Table 420 LRA ActionTable 422 Local Response Agent Variable Val
539. ystem chassis Table 5 3 Connection Status Variable Name De 1 1ConnectionStatus Data Type Integer Possible Data Values Meaning of Data Value unknown 2 The status of the chassis connection is unknown ok 3 The status of the chassis connection is OK failure 4 The status of the chassis connection is failure Chassis Information Group Table 5 4 Fan Control Capabilities Variable Name De11FanControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The fan s capabilities are unknown lowSpeedCapable 2 The fan can be set to low speed highSpeedCapable 4 The fan can be set to high speed lowOrHighSpeedCapable 6 The fan can be set to low or high speed Table 5 5 Front Panel LED Control Capabilities Variable Name De 11 LEDControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The LED control capabilities are unknown alertOnErrorCapable 2 The LED control can be set to alert on an error condition alertOnWarningAndErrorCap The LED control can be set to alert on an able 4 error and a warning condition alertOnWarningOrErrorCapa The LED control can be set to alert on an ble 6 error or a warning condition Table 5 6 Front Panel LED Control Settings Variable Name De11LEDControlSettings Data Type Integer Pos
540. zzaBox 5 The chassis type is a pizza box miniTower 6 The chassis type is a minitower tower 7 The chassis type is a tower portable 8 The chassis type is a portable lapTop 9 The chassis type is a laptop noteBook 10 The chassis type is a notebook handHeld 11 The chassis type is a handheld dockingStation 12 The chassis type is a docking station allInOne 13 The chassis type is an all in one Chassis Information Group 107 108 Table 5 2 Chassis Type continued Variable Name Del 1ChassisType Data Type Integer Possible Data Values Meaning of Data Value subNoteBook 14 The chassis type is a subnotebook spaceSaving 15 The chassis type is a spacesaver lunchBox 16 The chassis type is a lunch box mainSystemChassis 17 The chassis type is the main system chassis expansionChassis 18 The chassis type is an expansion chassis subChassis 19 The chassis type is a subchassis busExpansionChassis 20 The chassis type is a bus expansion chassis peripheralChassis 21 The chassis type is a peripheral chassis raidChassis 22 The chassis type is a disk RAID chassis rackMountChassis 23 The chassis type is a rack mounted chassis sealedCasePC 24 The chassis type is a sealed case chassis multiSystemChassis 25 The chassis type is a multis

Download Pdf Manuals