Home
Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Command Line Interface Guide
Contents
1. omconfig system pedestinations or omconfig servermodule pedestinations omconfig system platformevents or omconfig servermodule platformevents omconfig system events or omconfig servermodule events 4 omconfig system webserver or omconfig servermodule webserver omconfig system recovery or omconfig servermodule recovery 4 omconfig system shutdown or omconfig servermodule shutdown Contents omconfig system thrmshutdown or omconfig servermodule thrmshutdown 5 omconfig system or servermodule assetinfo Editing Cost of Ownership Values 2 bate ie he tile at eine Bae ss as User Level Required for Adding Asset Information 2000 Adding Acquisition Information Example Commands for Adding Acquisition Information 2004 Adding Depreciation Information Example Commands for Adding Depreciation Information 004 Adding Extended Warranty Information Example Command for Adding Extended Warranty Information Adding Lease Information Example Command for Adding Lease Information 2004 Adding Maintenance Information Example Command for Adding Maintenance Information 004 Adding Outsource Information Example Command for Adding Outsource Information aaa a Adding Owner Inf
2. omreport Connector Status omreport Cachecade Status omreport PCle SSD Status omreport Fluid Cache Status omreport Fluid Cache Pool Status omreport Partition Status omreport Fluid Cache Disk Status 8 omconfig storage Commands Contents omconfig Physical Disk Commands omconfig Blink Physical Disk omconfig Unblink Physical Disk omconfig Prepare to Remove Physical Disk omconfig Instant Erase Secured Physical Disk 2 2 0 000000 omconfig Initialize Physical Disk omconfig Offline PhysicalDisk omconfig Online Physical Disk omconfig Assign Global HotSpare omconfig Rebuild Physical Disk omconfig Cancel Rebuild Physical Disk 226 omconfig Cancel Replace Member 226 omconfig Clear Physical Disk 227 omconfig Cancel Clear Physical Disk 227 omconfig Enable Device Write Cache 228 omconfig Disable Device Write Cache 229 omconfig Export Reliability Log 229 omconfig Convert RAID to Non RAID 230 omconfig Convert Non RAID to RAID 231 omconfig Virtual Disk Commands 232 omconfig Check Consistency 233 omconfig Cancel Check Consistency 233 omconfig Pause Check Consistency 234 omconfig Resume Check Consistency 235
3. event removableflashmediafail Sets actions that Server Administrator performs when a removable flash media fails event storagesyswarn Sets actions when a storage system detects a warning value event storagesysfail Sets actions when a storage system detects a failure value event storagectrlwarn Sets actions when a storage controller detects a warning value event storagectrlfail Sets actions when a storage controller detects a failure value event pdiskwarn Sets actions when a physical disk detects a warning value event pdiskfail Sets actions when a physical disk detects a failure value event vdiskwarn Sets actions when a virtual disk detects a warning value event vdiskfail Sets actions when a virtual disk detects a failure value event enclosurewarn Sets actions when an enclosure detects a warning value event enclosurefail Sets actions when an enclosure detects a failure value event storagectrlbatterywarn Sets actions when a storage controller battery detects a warning value NOTE This event is not available on Blade systems omconfig Managing Components Using the Instrumentation Service 161 Table 4 23 Events for Which You Can Set Alert Actions continued Event Name Description event storagectrlbatteryfail Sets actions when a storage controller battery detects a failure value NOTE This event is not available on Blad
4. omconfig Command Summary Help With the omconfig Command omconfig about 05 omconfig chassis or omconfig mainsystem omconfig chassis biossetup or omconfig mainsystem biossetup omconfig chassis currents or omconfig mainsystem currents omconfig chassis fans or omconfig mainsystemfans 00005 omconfig chassis frontpanel or omconfig mainsystem frontpanel omconfig chassis info or omconfig mainsysteminfo 000 omconfig chassis leds or omconfig mainsystemleds 0005 omconfig chassis memorymode or omconfig mainsystem memorymode omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement omconfig chassis pwrmonitoring or omconfig mainsystem pwrmonitoring omconfig chassis remoteaccess or omconfig mainsystem remoteaccess omconfig chassis temps or omconfig mainsystemtemps 0 omconfig chassis volts or omconfig mainsystemvolts 0004 omconfig preferences omconfig preferences cdvformat omconfig preferences dirservice omconfig preferencessnmp omconfig preferences useraccess omconfig preferences webserver omconfig system or omconfig servermodule omconfig system alertaction or omconfig servermodule alertaction Commands for Clearing Logs
5. Network Data Network Interface 0 IP Address 1094 22 0171 Subnet Mask 129954295289470 Default Gateway 2 10 94 22 1 MAC Address 14 FE B5 FF AF DO Network Interface 1 IP Address No Value MAC Address 14 FE B5 FF AF D1 Network Interface 2 IP Address No Value MAC Address 14 FE B5 FF AF D2 omreport Viewing System Status Using the Instrumentation Service 85 Storage Enclosure Storage Enclosure Name Backplane The system summary hardware information includes data values for installed components of the following types present in the system System Attributes e Host Name e System Location e Life Cycle Controller Main System Chassis or Main System Chassis e Chassis Model e Chassis Service Tag e Express Service Code e Chassis Lock e Chassis Asset Tag Remote Access Information e Remote Access Device vFlash Media vFlash Media Size Processor The following are listed for each processor in the system e Processor Brand e Processor Family e Processor Version 86 omreport Viewing System Status Using the Instrumentation Service Current Speed Maximum Speed External Clock Speed Voltage Memory Total Installed Capacity Memory Available to the Operating System Total Maximum Capacity Memory Array Count Memory Array The following details are listed for each memory board or module in the system for example the system board or the memory m
6. Output Options for Command Results Controlling Command Output Display Writing Command OutputtoaFile Saving Command Results to a File That is Overwritten 2 0000005 Append Command Results to an Existing File Selecting a Format for the CLI Command Output List lst s 3 24 58i ole ek wee BS A Contents 295 295 295 296 296 297 299 Table tbl co ca sme deneden nak Semicolon separated Values ssv 301 Custom Delimited Format cdv 301 303 Contents 15 16 Contents Introduction Overview Dell OpenManage Server Administrator OMSA provides a comprehensive one to one systems management solution through either an integrated Web browser based graphical user interface GUI or a command line interface CLI Server Administrator is designed for system administrators to manage systems locally and remotely on a network It allows system administrators to focus on managing their entire network by providing a comprehensive one to one systems management In the context of Server Administrator a system refers to a stand alone system a system with attached network storage units in a separate chassis or a Blade system consisting of one or more server modules in a modular enclosure Server Administrator provides easy to use management and administration of local and remote systems through a comprehensive set of integrated management ser
7. Table 7 5 omreport Enclosure Commands Required Optional name value pairs Use Command Levels 1 2 3 omreport Displays property storage information for all enclosure enclosures attached to the system controller id Displays all enclosures where id is the controller number connected to the controller controller id enclosure Displays the specified lt ENCLOSUREID gt enclosure and its where id is the controller number and components lt ENCLOSUREID gt is the enclosure ID Example for SCSI controllers controller 0 enclosure 2 Example for SAS controllers controller 0 enclosure 1 2 206 omreport storage Commands The following sections provide the omreport storage enclosure command syntax required to execute the enclosure commands omreport Temperature Probe Status Table 7 6 describes the syntax for the omreport probe commands Table 7 6 omreport Temperature Probe Commands Required Command Levels 1 2 3 and name value pair Optional name value pairs Use omreport storage enclosure controller id enclosure lt ENCLOSUREID gt info temps where id is the controller number and lt ENCLOSUREID gt is the enclosure ID Example for SCSI controllers controller 0 enclosure 2 info temps Example for SAS controllers controller 0 enclosure 1 2 info temps controller id enclosure lt ENCLOSUREID gt info temps index n where id is the controller number and lt ENCLOSUREID
8. name lt text gt Name of the chassis In the following example the asset tag for the main system chassis is being set to buildsys omconfig chassis info index 0 tag buildsys or omconfig mainsystem info index 0 tag buildsys Index 0 always defaults to the main system chassis The following command omits index n but accomplishes the same thing omconfig chassis info tag buildsys or omconfig mainsystem info tag buildsys When the command is executed successfully the following message is displayed Chassis info set successfully 128 omconfig Managing Components Using the Instrumentation Service For some chassis you can assign a different name You cannot rename the main system chassis In the following example the command renames chassis 2 from storscsil to storscsia omconfig chassis info index 2 name storscsia or omconfig mainsystem info index 2 name storscsia As with other commands the CLI displays an error message if you do not have a chassis 2 the main chassis 0 The CLI allows you to issue commands only for the system configuration you have omconfig chassis leds or omconfig mainsystem leds Use the omconfig chassis leds or omconfig mainsystem leds command to specify when to flash a chassis fault LED or chassis identification LED This command also allows you to clear the LED of the system hard drive Table 4 8 lists the valid parameters for the command Table 4 8 Parameters of omconfig chassis leds or
9. omconfig storage vdisk action slowinit controller id vdisk id force yes Example Syntax To slow initialize virtual disk 4 on controller 1 type omconfig storage vdisk action slowinit controller 1 vdisk 4 omconfig Cancel Initialize Virtual Disk Use the following omconfig command syntax to cancel the initialization of a virtual disk Complete Syntax omconfig storage vdisk action cancelinitialize controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller Ds and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Example Syntax To cancel the initialization of virtual disk 4 on controller 1 type omconfig storage vdisk action cancelinitialize controller 1 vdisk 4 238 omconfig storage Commands omconfig Cancel Background Initialize Use the following omconfig command syntax to cancel the background initialization process on a virtual disk Complete Syntax omconfig storage vdisk action cancelbginitialize controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller
10. where id is the controller ID as reported by the omreport storage controller command Example Syntax To unlock the ecncrypted LKM configuration drives on controller 1 type omconfig storage controller action importsecureforeignconfig controller 1 passphrase Dell_123 omconfig Import Foreign Configuration Use the following omconfig command syntax to import all virtual disks that reside on physical disks newly attached to the controller Complete Syntax omconfig storage controller action importforeignconfig controller id where id is the controller ID as reported by the omreport storage controller command K NOTE This command is supported only in firmware version 5 0 x omconfig storage Commands 267 Example Syntax To import foreign configurations on controller 1 type omconfig storage controller action importforeignconfig controller 1 omconfig Import or Recover Foreign Configuration Use the following omconfig command syntax to import and recover all virtual disks that reside on physical disks newly attached to the controller Complete Syntax omconfig storage controller action importrecoverforeignconfig controller id where id is the controller ID as reported by the omreport storage controller command K NOTE This command is supported only on firmware version 5 1 1 Example Syntax To import and recover foreign configurations on controller 1 type omconfig storage controller action impo
11. 121 Table 4 4 BIOS Setup Settings on PowerEdge yx2x Systems continued Group name value pair 1 name value pair 2 attribute setting System attribute setting lt string gt Information SysMfrContactInfo attribute setting lt string gt SystemBiosVersion attribute setting lt string gt SystemManufacturer attribute setting lt string gt SystemModelName attribute setting lt string gt SystemService Tag System Profile attribute MemFrequency setting MaxPerf 1600MHz Settings 1333MHz 1067MHz 800MHz MaxReliability attribute MemPatrolScrub setting Standard Extended Disabled attribute setting 1x 2x MemRefreshRate attribute MemVolt setting AutoVolt Volt15V Volt 135V NOTE Volt15V represents 1 5 Volt and Volt135V represents 1 35 Volt attribute ProcClE setting Enabled Disabled attribute ProcCStates setting Enabled Disabled attribute ProcPwrPerf setting MaxPerf MinPwr SysDbpm OsDbpm attribute ProcTurboMode _ setting Enabled Disabled attribute SysProfile setting PerfPerWattOptimizedOs PerfPerWattOptimizedDapc PerfOptimized Custom DenseCfgOptimized System Security attribute AcPwrRevry setting On Off Last 122 omconfig Managing Components Using the Instrumentation Service Table 4 4 BIOS Setup Settings on PowerEdge yx2x Systems continued Group name value pair 1 name value pair 2 attribute setting attribute setting Immediate User AcPwr
12. Destination 8 destination 4 Displays the fourth destination Example 210 211 212 213 IPv4 address of the fourth destination destination 5 Displays the fifth destination Example 2001 0db8 85a3 0000 0000 8a2e 0370 7 334 IPv6 address of the fifth destination destination 6 Displays the sixth destination Example 2001 0db8 85a3 0000 0000 8a2e 0370 7 334 IPv6 address of the sixth destination destination 7 Displays the seventh destination Example 210 211 212 213 IPv4 address of the seventh destination destination 8 Displays the eighth destination 210 211 212 213 IPv4 address of the eighth destination Destination Configuration Settings attribute communitystring communitystring Displays the text string that acts as a password and is used to authenticate SNMP messages sent between the BMC and the destination management station omreport Viewing System Status Using the Instrumentation Service 79 omreport system platformevents or omreport servermodule platformevents Use the omreport system platformevents or omreport servermodule platformevents command to view how the system responds for each listed platform event K NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable omreport system recovery or omreport servermodule recovery Use the omreport system recovery or omreport servermodul
13. NOTE After installing Dell OpenManage Server Administrator ensure that you log out and log in to reset the path to access Dell OpenManage CLI utilities NOTE For information on the terms used in this document see the G ossary at dell com support manuals What s New in This Release The release highlights of OpenManage Server Administrator are 18 Support for reporting fluid cache fluid cache pool fluid cache disk and partition details See omreport storage Commands Support for applying and upgrading license to the fluid cache and updating cache configuration details See omcontfig Fluid Cache Commands Support for refreshing the storage partition details See omconfig Partition Command Support for disabling caching on a fluid cache disk See omcontig Fluid Cache Disk Command Support for enabling disabling and reactivating fluid cache for a specified virtual disk See omconfig Virtual Disk Commands Support for adding removing and reactivating PCIe SSD device in a cache pool See omconfig PCIe SSD Commands Added support for the following operating systems Introduction K Red Hat Enterprise Linux 6 SP2 64 bit Red Hat Enterprise Linux 6 SP3 64 bit Novell SUSE Linux Enterprise Server 11 SP2 64 bit Added support for the following platforms Dell PowerEdge R720 R820 R620 and T620 Added support for the following browsers Internet Explorer 10 Mozilla Firefox 10 11 an
14. Remote access MAC addresses System power Remote access IP address Ambient temperature of the system Remote access IPv4 address Remote access IPv6 address e Specify and configure the LCD line number e View the encryption state report of the LCD e Configure LCD to indicate an active remote session when the Kernel based Virtual Machine KVM is available K NOTE You can configure the Power and NMI buttons only if they are present on the system 126 omconfig Managing Components Using the Instrumentation Service Table 4 6 lists the valid parameters for the command Table 4 6 Parameters of omconfig chassis frontpanel or omconfig mainsystem frontpanel name value pair 1 name value Description pair 2 Icdindex lt index gt NA Specifies the LCD line number config none default NA none Sets the LCD text to none custom default Sets the LCD text to default custom Sets the LCD text to custom text lt custom text gt NA Sets the custom text for LCD when config custom nmibutton enable NA enable Enables the NMI button on the system disable disable Disables the NMI button on the system powerbutton enable NA true Enables the Power button on the system disable false Disables the Power button on the system config sysname NA Sets the name of the system config syspower NA Sets the system power information config servicetag NA Sets the syste
15. omconfig system events type Disables event No event notification lt component name gt severity notification none or omconfig servermodule events type lt component name gt severity none 170 omconfig Managing Components Using the Instrumentation Service Index Index refers to the number of an event for a particular component Index is an optional parameter When you omit the index parameter events are configured for all components of the specified type such as all fans For example when a system contains more than one fan you can enable or disable event notification for a particular fan An example command is as follows omconfig system events type fan index 0 severity critical Or omconfig servermodule events type fan index 0 severity critical As a result of the example command Server Administrator sends an SNMP trap only when the first fan in the system chassis index 0 has reached critical fan RPMs omconfig system webserver or omconfig servermodule webserver Use the omconfig system webserver or omconfig servermodule webserver command to start or stop the Web server Table 4 29 lists the valid parameters for the command Table 4 29 Web Server Configuration Parameters name value pair Description action start Starts the Web server action stop Stops the Web server action restart Restarts the Web server omconfig system recovery or omconfig servermodule recovery Use the
16. 273 omconfig create encryption key 263 Index 309 omconfig enable LKM controller 272 omconfig enclosure commands 287 290 292 293 omconfig global commands 282 omconfig offline physical disk 223 omconfig physical disk commands 218 omconfig physical disk power management 269 omconfig preferences 153 cdvformat 153 dirservice 154 snmp 155 useraccess 156 webserver 157 omconfig preferences dirservice name value pair parameters 154 omconfig preferences snmp name value pairs parameters 155 omconfig rekey LKM controller 272 omconfig set hot spare protection policy 285 omconfig set patrol read mode 269 omconfig start patrol read 270 omconfig stop patrol read 271 310 Index omconfig storage battery 281 connector 286 controller 249 enclosure 274 287 290 292 294 globalinfo 283 pdisk 198 218 vdisk 232 233 omconfig switch to LKM controller 272 omconfig system alertaction 158 alertlog 27 94 163 assetinfo 177 cmdlog 163 esmlog 163 events 168 extwarranty 181 name value pairs parameters 169 pedestinations 164 platformevents 164 recovery 171 shutdown 173 thrmshutdown 174 webserver 171 omconfig system assetinfo info acquisition 177 179 info depreciation 180 info extwarranty 182 info lease 184 info maintenance 185 info outsource 187 info owner 188 info service 190 info support 191 info system 193 i
17. BMC iDRAC and remote access controller if DRAC is installed Type omreport chassis remoteaccess or omreport mainsystem remoteaccess K NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable omreport Viewing System Status Using the Instrumentation Service 67 The output of the omreport chassis remoteaccess or omreport mainsystem remoteaccess command lists each of the valid parameters Table 3 6 lists the available settings Table 3 6 Valid parameters of omreport chassis remoteaccess or omreport mainsystem remoteaccess name value pair Description config additional Reports the current state of Pv and IPv6 addresses on iDRAC config advsol Reports advanced BMC iDRAC or remote access information on a serial over local area network LAN connection config nic Reports BMC iDRAC or remote access information for the LAN config serial Reports serial port information for BMC or remote access config serialoverlan Reports BMC iDRAC or remote access information on a serial over LAN connection config Reports terminal mode settings for the serial port terminalmode config user Reports information on BMC ADRAC or remote access users omreport chassis slots or omreport mainsystem slots Use the omreport chassis slots or omreport mainsystem slots command to view properties of the system s slots Type om
18. Example Syntax To cancel background initialization on virtual disk 4 on controller 1 type omconfig storage vdisk action cancelbginitialize controller 1 vdisk 4 omconfig Assign Dedicated Hot Spare Use the following omconfig command syntax to assign one or more physical disks to a virtual disk as a dedicated hot spare Complete Syntax omconfig storage vdisk action assigndedicatedhotspare controller id vdisk id pdisk lt PDISKID gt assign yes where id is the controller ID and virtual disk ID The lt PDISKID gt variable specifies the physical disk To obtain the values for the controller virtual disk and physical disk type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID and omreport storage pdisk controller ID to display the IDs for the virtual disks and physical disks attached to the controller omconfig storage Commands 239 Example Syntax To assign physical disk 3 on connector 0 of controller 1 as a dedicated hot spare to virtual disk 4 e For SCSI SATA and ATA controllers omconfig storage vdisk action assigndedicatedhotspare controller 1 vdisk 4 pdisk 0 3 assign yes e For SAS controllers omconfig storage vdisk action assigndedicatedhotspare controller 1 vdisk 4 pdisk 0 2 3 assign yes K NOTE On a SAS controller the physical disk resides in enclosure 2 omconfig Delete Virtual Disk Use the following omconfig command syntax to de
19. Setting the Minimum and Maximum Warning Threshold Values to Default To set both the maximum and minimum voltage warning threshold values to the recommended default value type omconfig chassis volts index 2 warnthresh default or omconfig mainsystem volts index 2 warnthresh default K NOTE You cannot default one value and set another In other words if you default the minimum warning threshold value you are also selecting the default value for the maximum warning threshold value 152 omconfig Managing Components Using the Instrumentation Service You cannot default one value and set another In other words if you default the minimum warning threshold value you are also selecting the default value for the maximum warning threshold value K NOTE Systems that contain ESM3 capabilities do not allow you to set warning threshold values to default values Specifying a Value for Minimum and Maximum Warning Thresholds To specify values for the voltage probe warning thresholds you must specify the number of the probe you are configuring and the minimum and or maximum warning threshold values In the following example the probe being configured is probe 0 omconfig chassis volts index 0 minwarnthresh 1 900 maxwarnthresh 2 250 or omconfig mainsystem volts index 0 minwarnthresh 1 900 maxwarnthresh 2 250 When you run the command and the system sets the values you specify the following message is displayed Voltage
20. System or boot partition residing on these virtual disks is destroyed You may receive a warning message if this command results in deleting the system or boot partition However this warning message is not generated always Ensure that you do not delete the system or boot partition or other vital data when using this command Complete Syntax omconfig storage controller action resetconfig controller id where id is the controller ID as reported by the omreport storage controller command In some circumstances you may receive a warning message if this command deletes the system or boot partition You can override this warning by using the force yes parameter In this case the syntax is as follows omconfig storage controller action resetconfig controller id force yes Example Syntax To reset the configuration on controller 1 type omconfig storage controller action resetconfig controller 1 omconfig Create Virtual Disk The Dell OpenManage Online Help provides additional information about creating virtual disks The omconfig syntax for creating a virtual disk has several parameters You must specify the following parameters e Controller controller id e RAID level raid lt c 10 rl rlc r5 r6 110 150 160 gt e Size size lt number max min gt omconfig storage Commands ___ 255 Physical disk is specified as either e For SCSI SATA and ATA controllers pdisk connector enclosureID targetID where connector
21. The event is a power supply failure and the action is to broadcast a message to all Server Administrator users Available Alert Actions Table 4 22 lists the alert actions for each component that allows you to configure an alert action Table 4 22 Alert Actions You Can Set for Warning and Failure Events Alert Action Setting Description alert true false true Enables the system s console alert When enabled the monitor attached to the system from which you are running Server Administrator displays a visual alert message false Disables the system s console alert broadcast true false true Enables a message or alert to broadcast to all users who have an active terminal or Remote Desktop session Windows or to operators that have an active shell on the local system Linux false Disables alert broadcasts clearall true Clears all actions for this event execappath lt string gt Sets the fully qualified path and file name of the application you want to execute in case of an event for the component described in this window NOTE On Linux systems user or user groups upgraded to administrator or administrator groups cannot configure this alert action setting execapp false Disables the executable application Components and Events for Which You Can Set Alert Actions Table 4 23 lists the components and the events for which you can set alert actions Components are listed in alphabetical ord
22. information required to execute the command successfully If you execute a command for a component or feature that is not present in the system configuration the error message states that the component is not present Command omconfig chassis volts index 3 minwarnthresh 3 3000 Message Error Number with up to 3 digits after decimal point expected read 3 3000 The value given by the command specifies more than 3 digits after the decimal point A valid minimum warning threshold value for volts contains up to 3 digits after the decimal point Revised command omconfig chassis volts index 3 minwarnthresh 3 300 When you type the revised command with three decimal points you receive another error message Error This voltage probe min warning threshold must be between 11 400 and 12 480 Revised command omconfig chassis volts index 3 minwarnthresh 11 500 Message Voltage probe warning threshold s set successfully 22 Introduction Scripting and Comparing Using CLI The Server Administrator CLI allows administrators to write batch programs for the operating system For an enterprise with many systems an administrator could write a configuration script that specified the warning thresholds for each major component of a system and also specified a set of actions that the administrator wants each system to take in case of a warning or failure event In the most critical cases the administrator could write a
23. lt auto disabled gt allowrevertibilehotspareandreplacemem ber enabled disabled autoreplacememberonpredictivefailure lt enabled disabled gt persistenthotspare enabled disabled rate lt 0 to 100 gt action discardpreservedcache controller id force lt enabled disabled gt action createsecuritykey controller id keyid lt keyid gt passphrase lt passphrase string gt escrow yes filepath lt Absolute path to the escrow file gt NOTE If you set escrow yes specify the escrow file path action changesecuritykey controller id keyid lt keyid gt passphrase lt passphrase string gt oldpassphrase lt oldpassphrase string gt escrow yes filepath lt Absolute path to the escrow file gt NOTE If you set escrow yes specify the escrow file path action deletesecuritykey controller id 250 omconfig storage Commands Table 8 4 omconfig Controller Commands continued Required Command Levels Optional name value pairs 1 2 3 action setbgirate controller id rate lt 0 to 100 gt action setreconstructrate controller id rate lt 0 to 100 gt action setcheckconsistencyrate controller id rate lt 0 to 100 gt action exportlog controller id action importsecureforeignconfig controller id passphrase lt passphrase for imported foreign configuration gt action importforeignconfig controller id action importrecoverforeignconfig controller id action clearforeignconfig controller id action setpdiskpwr
24. omconfig Blink Virtual Disk 235 omconfig Unblink Virtual Disk 236 omconfig Initialize Virtual Disk 236 omconfig Fast Initialize Virtual Disk 237 omconfig Slow Initialize Virtualize Disk 237 omconfig Cancel Initialize Virtual Disk 238 omconfig Cancel Background Initialize 239 omconfig Assign Dedicated Hot Spare 239 omconfig Delete Virtual Disk 240 omconfig Format Virtual Disk 241 omconfig Reconfiguring Virtual Disks 241 omconfig Secure Virtual Disk 243 omconfig Clear Virtual Disk Bad Blocks 243 omconfig Change Virtual Disk Policy 244 omconfig Replace Member Virtual Disk 245 omconfig Rename Virtual Disk 246 omconfig Enable Fluid Cache on Virtual Disk 247 omconfig Disable Fluid Cache on Virtual DISK 23 jek pave ae et ay ae RS 248 Contents 11 12 Contents omconfig Reactivate Fluid Cache on Virtual Disk 2 2 2 2 5 omconfig ControllerCommands omconfig Rescan Controller omconfig Enable Controller Alarm omconfig Disable Controller Alarm omconfig Quiet ControllerAlarm omconfig Test Controller Alarm omconfig Reset Controller Configuration omconfig Create Virtual Disk omconfig Set Controller Rebuild Rate omconfig Change Controller Properties omconfig Discard Preserved C
25. omconfig storage Storage Management requires Administrator privileges to use the omconfig storage command User and Power User privileges are sufficient to use the omreport storage command 200 Using the Storage Management Service omreport storage Commands The omreport command allows you to view storage component information for disks controllers enclosures batteries global storage properties connectors cachecades fluid cache and partitions that are part of the storage system This chapter explains how to get reports with the level of detail that you want Commands documented in this chapter vary in whether they define the fields that appear in the results of a particular omreport command Fields are defined only if they have a special or less familiar use The following sections provide the omreport command syntax required to display the information of various storage components To see a list of valid commands for omreport storage type omreport storage Table 7 1 provides the omreport storage command syntax Table 7 1 Syntax for omreport storage help Command Command Command Level 3 Use Level 1 Level 2 omreport storage Displays a list of storage components for which omreport commands are available pdisk Displays a list of the omreport storage pdisk parameters for displaying physical disk information vdisk Displays a list of omreport storage vdisk parameters for displaying virtual disk informati
26. see Example Commands for Adding Acquisition Information on page 179 Adding Support Information Support refers to technical assistance that the system user can seek when the user seeks guidance on the proper use of a system to perform tasks Table 5 10 lists the valid parameters for adding support information Table 5 10 Parameters of omconfig system assetinfo info support or omconfig servermodule assetinfo info support Command CommandLevel Command Name Name Value Pair 2 Description Level 1 2 Level3 Value Pair 1 omconfig system or servermodule assetinfo info support 190 omconfig system or servermodule assetinfo Editing Cost of Ownership Values Table 5 10 Parameters of omconfig system assetinfo info support or omconfig servermodule assetinfo info support continued Command CommandLevel Command Name Name Value Pair 2 Description Level 1 2 Level3 Value Pair 1 automaticfix Name of any lt programname gt application used to fix a problem automatically helpdesk The help desk name lt text gt or contact outsourced true false type network storage information such as a phone number e mail address or website address Whether an external business entity provides technical support or the system owner s employees provide technical support Whether support is for network attached devices or for storage devices Example Command for Adding Support Information To provide
27. 145 Table 4 12 Parameters of omconfig chassis remoteaccess or omconfig mainsystem remoteaccess continued name value pair 1 name value pair 2 Description config newlinesequence none none BMC does not use a crlf null cr lfcr If termination sequence crlf BMC uses lt CR LF gt as a new line sequence when the BMC writes a new line to the console null BMC uses lt Null gt as a new line sequence when the BMC writes a new line to the console cr BMC uses lt CR gt as a new line sequence when the BMC writes a new line to the console lfcr BMC uses lt LF CR gt as a new line sequence when the BMC writes a new line to the console lf BMC uses lt LF gt as a new line sequence when the BMC writes a new line to the console config user id number enable true id number ID in numeric format of false the user being configured enable true Enables the user enable false Disables the user id number id number ID in numeric format of enableserialoverlan true the user being configured false enableserialoverlan true Enables serial over LAN enableserialoverlan false Disables serial over LAN NOTE The enableserialoverlan option is supported only on PowerEdge x9xx systems id number name text id number ID in numeric format of the user being configured name text Name of the user 146 omconfig Managing Components Using the Instrumentation Service Table 4 12 Paramet
28. 4 minwarnthresh 11 2 maxwarnthresh 58 7 When you run the command and the system sets the values you specify the following message is displayed Temperature probe warning threshold s set successfully K NOTE On PowerEdge x8xx and x9xx systems you can set the temperature probe warning threshold only for ambient temperature omconfig Managing Components Using the Instrumentation Service 151 omconfig chassis volts or omconfig mainsystem volts Use the omconfig chassis volts or omconfig mainsystem volts command to set voltage probe warning thresholds As with the other components you can view both the warning and failure threshold values but you cannot set the failure threshold values The system manufacturer sets the minimum and maximum values for the failure thresholds Valid Parameters for Voltage Warning Thresholds The following table displays the valid parameters for setting voltage warning threshold values K NOTE Threshold values that you can set vary from one system configuration to another Table 4 16 Parameters of omconfig chassis volts or omconfig mainsystem volts name value pair Description index lt n gt Probe index specify warnthresh default Sets minimum and maximum warning threshold values to default minwarnthresh lt n gt Sets minimum warning threshold value three decimal places maxwarnthresh lt n gt Sets maximum warning threshold value three decimal places
29. 50 on controller 1 type omconfig storage controller action setcheckconsistencyrate controller 1 rate 50 omconfig Export the Controller Log Use the following omconfig command syntax to export the controller log to a text file See the Dell OpenManage Online Help for more information about the exported log file Complete Syntax omconfig storage controller action exportlog controller id where id is the controller ID as reported by the omreport storage controller command Example Syntax To export the log on controller 1 type omconfig storage controller action exportlog controller 1 By default the log file is exported to C WINNT or C Windows on Microsoft Windows systems based on the Windows version used and var log on all Linux systems 266 omconfig storage Commands Depending on the controller the log file name is afa_ lt mmdd gt log or Isi_ lt mmdd gt log where lt mmdd gt is the month and date See the Dell OpenManage Online Help for more information on the controller log file K NOTE The export log file command is not supported on the 4 IM CERC ATA and 100 4ch controllers omconfig Import Secure Foreign Configuration Use the following omconfig command syntax to unlock the encrypted Local Key Management LKM foreign configuration drives Complete Syntax omconfig storage controller action importsecureforeignconfig controller id passphrase lt passphrase string for the foreign configuration gt
30. Disables DBS on the system attribute diskette setting off auto writeprotect off Disables the diskette drive auto Auto enables the diskette drive writeprotect The diskette drive is available in read only format only Make the diskette drive read only omconfig Managing Components Using the Instrumentation Service Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems continued name value pair 1 attribute name value pair 2 setting Description attribute dualnic setting off on pxeboth nicl pxe nic2pxe isciboth niclisci nic2isci nicl pxenic2isci nicliscinic2pxe onpxeboth onpxenone onpxenicl onpxenic2 off Disables the Network Interface Controllers NICs on Enables the network interface PXE or iSCSI is not enabled on either of the NICs pxeboth Enables PXE on both NICs nicl pxe Enables PXE on the first NIC and none no PXE or iSCSI on the second NIC nic2pxe Enables none no PXE or iSCSI on first NIC and PXE on the second NIC isciboth Enables iSCSI on both the NICs niclisci Enables iSCSI on the first NIC and none no PXE or iSCSI on the second NIC nic2isci Enables none no PXE or iSCSI on the first NIC and iSCSI on the second NIC nicl pxenic2isci Enables PXE on the first NIC and iSCSI on second NIC nicliscinic2pxe Enables iSCSI on the first NIC and PXE on second NIC NOTE The following options ar
31. For SAS controllers omconfig storage pdisk action blink controller 1 pdisk 0 2 0 K NOTE On a SAS controller the physical disk resides in enclosure 2 omconfig Unblink Physical Disk You can disable the light light emitting diode or LED display on one or more physical disks attached to a controller Use the following omconfig command syntax to unblink one or more physical disks Complete Syntax omconfig storage pdisk action unblink controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To disable the LED on physical disk 0 on connector 0 of controller 1 e For SCSI SATA and ATA controllers omconfig storage pdisk action unblink controller 1 pdisk 0 0 e For SAS controllers omconfig storage pdisk action unblink controller 1 pdisk 0 2 0 K NOTE On a SAS controller the physical disk resides in enclosure 2 220 omconfig storage Commands omconfig Prepare to Remove Physical Disk Use the following omconfig command syntax to prepare a physical disk for removal Complete Syntax omconfig storage pdisk action remove controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physic
32. ID as reported by the omreport command To obtain the values for controller ID and virtual disk ID type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Example Syntax For example to clear bad blocks on virtual disk 4 on controller 1 type omconfig storage vdisk action clearvdbadblocks controller 1 vdisk 4 omconfig storage Commands 243 omconfig Change Virtual Disk Policy Use the following omconfig command syntax to change a virtual disk s read write or cache policy Complete Syntax omconfig storage vdisk action changepolicy controller id vdisk id diskcachepolicy lt enabled disabled gt readpolicy lt ra nra aral re nre gt writepolicy lt wb wt wc nwc gt fwb gt cachepolicy lt d c gt where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller See the Dell OpenManage Online Help for more information about the controller specific diskcache read write and cache policy For information on specifying these parameters using the omconfig command see the following e readpolicy lt ra nra ara rc nrc gt parameter optional e w
33. K NOTE To check if the controller has a preserved cache type omreport storage controller controller id Ifthe system displays Preserved Cache yes it indicates the presence of the preserved cache Complete Syntax omconfig storage controller action discardpreservedcache controller id force enabled disabled If you set force enabled the cache is discarded irrespective of whether the controller detects a foreign or an offline virtual disk 262 omconfig storage Commands Example Syntax To discard the preserved cache type omconfig storage controller action discardpreservedcache controller 1 force enabled A CAUTION Discarding the preserved cache can result in data loss It is recommended that you run this command using the force disab ed option NOTE If a foreign configuration is detected then the preceding command using force disabled option fails To avoid data loss import the foreign configuration and flush the preserved cache to disk To discard preserved cache forcefully either clear the foreign configuration and run the proceeding command or run the proceeding command using force enabled option omconfig Create Encryption Key Use the following omconfig storage command syntax to create the encryption key for the controller Complete Syntax omconfig storage controller action createsecuritykey controller id keyid lt keyid string gt passphrase lt passphrase string gt escrow yes filepath lt Absolute
34. Reports events for temperatures type removableflashmedia Reports events for removable flash media type volts Reports events for voltages Example Command for an Event Type Type omreport system events type fans or omreport servermodule events type fans The following is an example output Current SNMP Trap Configuration Settings Enable Informational Warning and Critical Disable None 76 omreport Viewing System Status Using the Instrumentation Service Settings Enable Informational Warning and Critical Disable None System Board Fanl RPM Settings Index 0 Enable Informational Warning and Critical Disable None System Board Fan2 RPM Settings Index 1 Enable Informational Warning and Critical Disable None omreport system operatingsystem or omreport servermodule operatingsystem Use the omreport system operatingsystem or omreport servermodule operatingsystem command to display information about the operating system omreport system pedestinations or omreport servermodule pedestinations Use the omreport system pedestinations or omreport servermodule pedestinations command to view destinations where alerts are sent for platform events Depending on the number of destinations displayed configure a separate IP address for each destination address omreport Viewing System Status Using the Instrumentation Service 71 Type omreport system pedestinations o
35. Service Cod Value 18955029124 omreport Viewing System Status Using the Instrumentation Service 39 CMC Information Attribute Product Value Chassis Management Controller CMC Attribute Description Value The system component provides a complete set of remote management functions for Dell systems Attribute Version Value 3 20 Attribute IP Address Value 101 102 103 104 Attribute IP Address Source Value Dynamic Source Attribute IP Address Type Value IPv4 Attribute Remote Connect Interface Value Launch CMC Web Interface omreport about Use the omreport about command to learn the product name and version number of the systems management application installed on the system The following is an example output from the omreport about command Product name Dell OpenManage Server Administrator Version KE Copyright Copyright C Dell Inc xxxx xxxx All rights reserved Company Dell Inc For details about the environment for Server Administrator type omreport about details true 40 omreport Viewing System Status Using the Instrumentation Service Server Administrator includes a number of services each of which has a version number of its own The Contains field reports version numbers for the services as well as other useful details The following output is an example and can change depending on the system s configuration and the version of Server Administra
36. Status Using the Instrumentation Service 71 Overall Health Status of the ESM Log When you run the omreport system esmlog or omreport servermodule esmlog command the ESM log is displayed The first line of the report reflects the overall health of the system hardware For example Health OK means that less than 80 percent of the space allotted for the ESM log is occupied by messages If 80 percent or more of the allotted space for the ESM log is occupied the following caution is displayed Health Non Critical If a caution is displayed resolve all warning and critical severity conditions and then clear the log omreport system alertaction or omreport servermodule alertaction Use the omreport system alertaction or omreport servermodule alertaction command to view a summary of alert actions that have been configured for warning and failure events on the system components Alert actions determine how Server Administrator responds when a component has a warning or failure event The omreport system alertaction or omreport servermodule alertaction command is useful for viewing which alert actions have been specified for components To set an alert action for a component use the omconfig system alertaction or omconfig servermodule alertaction command For more information see omconfig Managing Components Using the Instrumentation Service on page 91 K NOTE To maintain consistency across the commands the output format of this c
37. System Status Using the Instrumentation Service Express Service Code Chassis Lock Chassis Asset Tag Remote Access Information Remote Access Device vFlash Media Processor 1 Processor Brand Processor Version Voltage Memory Total Installed Capacity Memory Available to the OS Total Maximum Capacity emory Array 1 Location USE Installed Capacity LDRAC7 Genuine Intel R emory Array Count 15608862073 Present 7 Cc Express Absent CPU 1 60GHz Model 45 Stepping 2 1200 W 2048 MB 2048 MB 786432 MB System Board or Motherboard System Memory 2048 MB omreport Viewing System Status Using the Instrumentation Service 83 Maximum Capacity Slots Available Slots Used Slot PCI1 Adapter Type Data Bus Width Speed Slot Length Voltage Supply Slot PCI2 Adapter Type Data Bus Width Speed Slot Length Voltage Supply BIOS Information Manufacturer Version Release Date 84 786432 MB 24 eee Not Occupied PCI E Gen 3 X16 8x or x8 Not obtained see card documentation Long gt 3 3 Volts Not Occupied PCI E Gen 3 X16 8x or x8 Not obtained see card documentation Long gt 3 3 Volts Dell Inc 2106 3 5 05 16 2011 omreport Viewing System Status Using the Instrumentation Service Firmware Information Name 1DRAC7 Version 1 00
38. This option is supported on systems prior to PowerEdge yx2x systems profile maxperformance apc osctrl custom cpupowermode min max systemdbpm osdbpm maxperformance Sets the processor to the highest supported processor state It offers maximum performance mode with minimal power economy ape Active Power Control apc enables the demand based power management controlled by BIOS osctrl OS Control osctrl enables the demand based power management controlled by the operating system custom This profile allows you to configure individual BIOS settings It offers added control by displaying the underlying BIOS settings min Sets the CPU power consumption to minimum max Sets the CPU power consumption to maximum systemdbpm Sets the mode to system demand based power management osdbpm Sets the mode to operating system demand based power management NOTE These options are applicable only when a custom profile is selected omconfig Managing Components Using the Instrumentation Service 133 Table 4 10 Parameters of omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement continued name value pair 1 name value pair 2 Description memorypowermode _ min Sets the mode to minimum min 800 1067 power utilization 1333 max 800 1067 1333 Set the mode to 800 1067 or 1333 MHz max Sets the mode to maximum performance NOTE These options are applicable
39. Web server attribute getsignalgorithm Reports the current key sign algorithm omreport Viewing System Status Using the Instrumentation Service omconfig Managing Components Using the Instrumentation Service The omconfig command allows you to provide values that define warning events configure alert actions clear logs and configure system shutdown as well as perform other systems management tasks Examples of omconfig capabilities include e Administrator privilege to clear command alert and hardware logs e Administrator privilege to configure and execute system shutdown e Power user and administrator privilege to specify values for warning events on fans voltage probes and temperature probes e Power user and administrator privilege to set alert actions in case of a warning or failure event from intrusion fans voltage probes and temperature probes For information on using the omconfig command to view and manage cost of ownership information assetinfo see omconfig system or servermodule assetinfo Editing Cost of Ownership Values on page 177 Often you must use the omreport command to get the information required to execute an omconfig command For example to edit the minimum temperature for a warning event on a temperature probe you must know the index of the probe Use the omreport chassis temps or omreport mainsystem temp command to display a list of probes and their indexes For more information on us
40. a E a 280 omconfig Blink oaaae 280 omconfig Battery Commands 281 omconfig Start Battery LearnCycle 281 omconfig Delay Battery LearnCycle 282 omconfig Global Commands 282 omconfig Global Enable Smart Thermal Shutdown aoaaa aaa a 283 omconfig Global Disable Smart Thermal Shutdown 22 20004 284 omconfig Global Rescan Controller 285 omconfig Set Hot Spare Protection Policy 285 omconfig ConnectorCommands 286 omconfig RescanConnector 286 omconfig Cachecade Commands 287 omconfig Blink Cachecade 287 Contents 13 omconfig Unblink Cachecade omconfig Delete Cachecade omconfig Resize Cachecade omconfig Rename Cachecade omconfig PCle SSD Commands omconfig Add PCle SSD Device to Cachepool ss nedera eRe eee eas omconfig Remove PCle SSD Device From Cachepool moes i eee eee ee ee a es omconfig Reactivate PCle SSD Device omconfig Fluid Cache Commands omconfig Applying or Updating License to the Fluid Cache sses 23 fos Bore ese 28 omconfig Conecting to the Fluid Cache omconfig PartitionCommand omconfig Refreshing Partition List omconfig Fluid Cache Disk Command omconfig Discarding Data and Disabling GaChinghs son heli taco ety etl eh a e 9 Working With CLI Command Results
41. about the syntax and use of the command appear later in this section Table 3 2 lists the omreport commands available for about system and main system chassis For information about viewing storage components see omreport Viewing System Status Using the Instrumentation Service on page 31 32 omreport Viewing System Status Using the Instrumentation Service Table 3 2 Command Level 1 Level 2 and Level 3 for omreport Command Command Level 2 Command Level 1 Level 3 User Privilege Required Use omreport modularenclosure about details true chassis or mainsystem acswitch batteries bios biossetup U P A U PA U P A U PA U P A U PA U P A Displays the information for all the modular chassis Displays the version number and properties for Server Administrator Displays the information for all the Server Administrator programs installed Displays the general status of all the main components Displays the failover settings where redundant AC power lines are supported in a system Displays the properties set for batteries Displays the BIOS information such as manufacturer version and release date Displays the BIOS setup properties configured during system boot omreport Viewing System Status Using the Instrumentation Service 33 Table 3 2 Command Level 1 Level 2 and Level 3 for omreport continued Command Command Level 2 Command Le
42. alert log the command log and the hardware or ESM log To clear the contents of the alert log type omconfig system alertlog action clear or omconfig servermodule alertlog action clear K NOTE Entering an invalid RAC user name may prevent the command log from displaying Clearing the command log resolves this condition To clear the contents of the command log type omconfig system cmdlog action clear or omconfig servermodule cmdlog action clear To clear the contents of the ESM log type omconfig system esmlog action clear Or omconfig servermodule esmlog action clear omconfig Managing Components Using the Instrumentation Service 163 omconfig system pedestinations or omconfig servermodule pedestinations Use the omconfig system pedestinations or omconfig servermodule pedestinations command to set IP addresses for alert destinations Table 4 24 lists the valid parameters for the command K NOTE You can either specify the index and IP address as parameters together or you can set the community string alone as a parameter NOTE Index 1 to 4 accepts an IPv4 address and index 5 to 8 accepts an IPv6 address Table 4 24 Parameters of omconfig system pedestinations or omconfig servermodule pedestinations name Value Pair Description destenable true true Enables an individual platform event filter destination false after a valid IP address has been set false Disables an individual p
43. and XenMotion are either re gistered trademarks or trademarks of Citrix Systems Inc in the United States and or other countries Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products Dell Inc disclaims any proprietary interest in trademarks and trade names other than its own 2013 03 Contents 1 Introduction 0 17 OVOIVIOW 2 recreire saum eee 17 What s New in This Release 18 Accessing the Windows Command Prompt to Run CLI Commands ouaaa 19 Primary CLI Commands 19 CLI Error Checking and Error Messages 21 Success Messages 21 Failure Messages nnana ahaaa aaa 22 Scripting and Comparing Using CLI 23 Command Syntax Overview 24 2 Using the omhelp Command 27 Example HelpCommands 27 3 omreport Viewing System Status Using the Instrumentation Service 31 Conventions for Parameter Tables 32 Command Summary of the omreportCommand 32 Help With the omreport Command 39 Contents Contents omreport modularenclosure omreport about omreport chassis or omreport mainsystem Commands aoaaa aaa omreport chassis or omreport mainsystem omreport chassis acswitch or omreport mainsystem acswitch aoaaa omreport chassis
44. and copies the failing module s data to a spare bank mirror Switches the systems to a mirrored copy of the memory if the failing module has an uncorrectable memory event In mirror mode the operating system does not switch back to the original module until the system reboots disabled Indicates that the system is not to use other available memory modules if uncorrectable memory events are detected raid5 Method of system memory configuration This is logically similar to the RAID 5 mode used in hard drive storage systems This memory mode provides an extra level of memory checking and error recovery at the expense of some memory capacity The RAID mode supported is RAID level 5 striping with rotational parity ddde The ddde mode enables double device data correction This ensures data availability after hard failure of xt DRAM opmode mirror optimizer advecc mirror Switches the systems to a mirrored copy of the memory if the failing module has an uncorrectable memory event In mirror mode the operating system does not switch back to the original module until the system reboots optimizer Enables the DRAM controllers to operate independently in 64 bit mode and provide optimized memory performance advanced ECC advecc Enables the two DRAM controllers to combine in 128 bit mode and provide optimized reliability Memory that are not teamed by the controllers is not reported to the operating system omconfig
45. assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to name value pair 1 For an example see Example Commands for Adding Acquisition Information on page 179 Adding Lease Information A lease is an agreement to pay for the use of a system for a specified period of time The lessor retains ownership of the system Table 5 5 lists the valid parameters for the command Table 5 5 Parameters of omconfig system assetinfo info lease or omconfig servermodule assetinfo info lease Command CommandLevel Command Name Value Name Value Description Level 1 2 Level3 Pair Pair 2 omconfig system or servermodule assetinfo info lease buyout Amount of money paid lt amount gt to purchase a system from a lessor lessor Business entity that is lt lessor gt leasing the system out multischedule Whether cost of leasing ttue false the system is computed by more than one rate schedule ratefactor Factor used to calculate lt factor gt the lease payment value Fair market value of the lt residual gt system at the end of the lease period omconfig system or servermodule assetinfo Editing Cost of Ownership Values 183 Example Command for Adding Lease Information To provide a value for a lease parameter type a command of the form omconfig system assetinfo info lease lt name value pair 2 gt or omconfig servermodule assetinfo info lease lt
46. asterisk tilde question colon comma and pipe The following example shows how to set the delimiter for separating data fields to asterisk omconfig preferences cdvformat delimiter asterisk Working With CLI Command Results 301 302 Working With CLI Command Results Index Symbols omcontig 97 omcontig chassis 100 omreport 39 request for help 27 A about omcontig 98 acquisition information 177 optional parameters 29 acquisition information adding 177 acswitch omreport chassis 42 omreport command level 3 42 adapter omreport chassis slots 69 alert action defining 158 example valid commands 162 setting 158 setting events 160 alertaction omconfig system 158 omreport system 72 alertlog clearing logs 163 omcontig system 27 94 omreport system 71 arrays memory 35 87 asset information 177 assetinfo acquisition 74 omreport system 74 assign dedicated hot spare omconfig 239 assign global hot spare omconfig 224 available alert actions 159 B base I O address omreport chassis ports 58 battery ID 200 omcontig storage 281 omreport storage 211 213 status 211 bios omreport chassis 43 biossetup Index 303 omcontig chassis 100 omreport chassis 44 blink omconfig 280 blink physical disk omconfig 219 bmc omconfig chassis 136 omreport chassis 67 C cache policy parameters 259 cache properties omreport chassi
47. batteries or omreport mainsystem batteries oaoa aaa omreport chassis bios or omreport mainsystem bios oaoa a omreport chassis biossetup or omreport mainsystem biossetup o oo aaa omreport chassis currents or omreport mainsystem currents o oo a omreport chassis removableflashmedia or omreport mainsystem removableflashmedia omreport chassis fans or omreport mainsystem fans aoaaa a omreport chassis firmware or omreport mainsystem firmware aoaaa aa omreport chassis frontpanel or omreport mainsystem frontpanel omreport chassis fru or omreport mainsystem fru aoaaa a omreport chassis hwperformance or omreport mainsystem hwperformance omreport chassis info or omreport mainsysteminfo 00 0000s omreport chassis intrusion omreport chassis leds or omreport mainsystem leds 00004 omreport chassis memory or omreport mainsystem memory 0006 omreport chassis nics or omreport mainsystemnics 00000 omreport chassis ports or omreport mainsystem ports 0000 omreport chassis processors or omreport mainsystem processors 4 omreport chassis pwrmanagement or omreport mainsystem pwrmanagement omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring omreport chassis pwrsupplies or omreport mainsystem pwrsupplies omreport chassis remoteaccess
48. cachepolicy lt wb wt gt action disablefluidcache controller id vdisk id devicename lt string gt action reactivate controller id vdisk id devicename lt string gt omconfig Check Consistency Use the following omconfig command syntax to initiate a check consistency ona virtual disk The check consistency task verifies the virtual disk s redundant data Complete Syntax omconfig storage vdisk action checkconsistency controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Example Syntax To run a check consistency on virtual disk 4 on controller 1 type omconfig storage vdisk action checkconsistency controller 1 vdisk 4 omconfig Cancel Check Consistency Use the following omconfig command syntax to cancel a check consistency while in progress omconfig storage Commands 233 Complete Syntax omconfig storage vdisk action cancelcheckconsistency controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller Ds and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the cont
49. command command level 1 one or more subcommands command level 2 and command level 3 if present and one or more name value pair s By appending space dash question mark to any command you can get help for that command Example Help Commands When you type omconfig you get general help about the omconfig command The help at this level lists the available subcommands for omconfig e about e preferences e chassis e system When you type omconfig system CLI help lists all the subcommands available for omconfig system e alertaction e alertlog e assetinfo cmdlog e esmlog e events e platformevents e pedestinations Using the omhelp Command 27 e recovery e shutdown e thrmshutdown e webserver Figure 2 1 shows the levels of help for a command Figure 2 1 Different Levels of Help for a Command omconfig omconfig system levels for help omconfig system assetinfo omconfig system assetinfo info depreciation omconfig system assetinfo info depreciation method lt tex gt 4 level for command execution Also parse the omconfig system assetinfo command as follows lt command level 1 command level 2 command level 3 gt lt name value pair 1 gt name value pair 2 where command levels 1 2 and 3 are represented by omconfig system assetinfo name value pair is represented by info depreciation and name value pair 2 is represented by method straightline To set the
50. controller Example Syntax To disable fluid cache on virtual disk 4 on controller 1 type omconfig storage vdisk action disablefluidcache controller 1 vdisk 4 devicename dev sdb 248 omconfig storage Commands omconfig Reactivate Fluid Cache on Virtual Disk Use the following omconfig command syntax to reactivate the fluid cache for the specified virtual disk Complete Syntax omconfig storage vdisk action reactivate controller id vdisk id devicename lt string gt where id is the controller ID and virtual disk ID as reported by the omreport command and lt string gt is the device name of the virtual disk To obtain the values for controller ID and virtual disk ID type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Example Syntax To reactivate fluid cache on virtual disk 4 on controller 1 type omconfig storage vdisk action reactivate controller 1 vdisk 4 devicename dev sdb omconfig Controller Commands The following sections provide the omconfig command syntax required to execute controller tasks VAN CAUTION The omconfig storage controller action resetcontig controller id resets the controller configuration Resetting the controller configuration permanently destroys all data on all virtual disks attached to the controller System or boot partition residing on these virtu
51. controller 0 type omconfig storage controller action convertraidtononraid controller 0 pdisk 0 2 3 omconfig Convert Multiple Non RAID to RAID Use the following omconfig storage command syntax to convert multiple non RAID to RAID on the given controller Complete Syntax omconfig storage controller action convertnonraidtoraid controller id pdisk lt PDISKID gt where id is the controller ID as reported by the omreport storage controller command and PDISKID is specified as pdisk connector enclosureID targetID connector targetID Example Syntax To convert multiple non RAID to RAID on controller 0 type omconfig storage controller action convertnonraidtoraid controller 0 pdisk 0 2 3 omconfig storage Commands 273 Omconfig Enclosure Commands The following sections provide the omconfig command syntax required to execute enclosure tasks Table 8 11 omconfig Enclosure Commands Required Command Levels 1 2 3 Optional name value pairs omconfig storage enclosure action enablealarm controller id enclosure lt ENCLOSUREID gt action disablealarm controller id enclosure lt ENCLOSUREID gt action setassettag controller id enclosure lt ENCLOSUREID gt assettag lt string gt action setassetname controller id enclosure lt ENCLOSUREID gt assetname lt string gt action settempprobes controller id enclosure lt ENCLOSUREID gt index id minwarn n maxwarn n action resettempprobes controller id e
52. depreciation method to straight line type omconfig system assetinfo info depreciation method straightline The CLI responds with the following message Asset information set successfully When you type omconfig system assetinfo the help that is displayed provides information about assigning values for the name and option fields Partial results for the request omconfig system assetinfo are as follows assetinfo Set asset information 28 Using the omhelp Command For one info value specify one or more optional parameter s Table 2 1 lists the optional parameters for info acquisition Table 2 1 Optional Parameters Info Value Optional parameters Info acquisition purchasecost lt num gt waybill lt num gt installdate lt mmddyy gt purchasedate lt mmddyy gt ponum lt num gt signauth lt text gt expensed lt yes no gt costcenter lt text gt info depreciation method lt text gt duration lt num gt percent lt percent gt unit lt months years unknown gt Using the omhelp Command __ 29 30 Using the omhelp Command omreport Viewing System Status Using the Instrumentation Service The omreport command allows you to see detailed information about the system components You can also retrieve summaries for many system components at one time or get details about a specific component This chapter shows you how to get reports with the level of detail that you want Command
53. disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Example Syntax To format virtual disk 4 on controller 1 type omconfig storage vdisk action format controller 1 vdisk 4 omconfig Reconfiguring Virtual Disks You can reconfigure a virtual disk to change the virtual disk s RAID level or increase its size by either adding physical disks or using the available free space On some controllers you can also remove physical disks Complete Syntax omconfig storage vdisk action reconfigure controller id vdisk id raid lt c rO rl ric r5 r6 rl0 gt pdisk lt PDISK gt size lt size gt vdcapacityexpansion yes sizeinpercent lt 1 to 100 gt omconfig storage Commands 241 Example Syntax To reconfigure virtual disk 4 to a size of 800 MB use RAID 5 and physical disks 0 through 3 on connector 0 of controller 1 e For SCSI SATA and ATA controllers omconfig storage vdisk action reconfigure controller 1 vdisk 4 raid r5 size 800m pdisk 070 021 2022 053 e For SAS controllers omconfig storage vdisk action reconfigure controller 1 vdisk 4 raid r5 pdisk 0 2 0 0 2 1 0 2 2 0 2 3 K NOTE On a SAS controller the physical disk resides in enclosure 2 Example Syntax To increase the size of the virtual disk by 20 pe
54. encl43 for the enclosure attached to connector 2 on controller 1 e For SCSI SATA and ATA controllers omconfig storage enclosure action setassetnam controller 1 enclosure 2 assetname encl43 e For SAS controllers omconfig storage enclosure action setassetnam controller 1 enclosure 1 2 assetname encl43 omconfig Set Temperature Probe Thresholds Use the following omconfig command syntax to set the minimum and maximum warning temperature thresholds for a specified temperature probe K NOTE This command is not supported on SAS controllers omconfig storage Commands 277 Complete Syntax omconfig storage enclosure action settempprobes controller id enclosure lt ENCLOSUREID gt index id minwarn n maxwarn n where id is the controller ID and the temperature probe ID The lt ENCLOSUREID gt variable specifies the enclosure In this syntax n is a user specified value for the temperature in Celsius Example Syntax To set the temperature probe thresholds to 10 and 40 degree Celsius e For SCSI SATA and ATA controllers omconfig storage enclosure action settempprobes controller 1 enclosure 2 index 3 minwarn 10 maxwarn 40 K NOTE Here temperature probe 3 resides in the enclosure attached to connector 2 on controller 1 omconfig Reset Temperature Probe Thresholds Use the following omconfig command syntax to reset the minimum and maximum warning temperature thresholds back to their default val
55. failure thresholds 124 configuring Active Directory service 154 system events 168 configuring power button NMI button 126 Connector 213 connector omcontig storage 286 connector commands omcontig 286 connector name omreport chassis processors 58 connector status omreport 212 controller battery 211 213 BMC 67 79 96 display IDs 199 omconfig storage 249 omreport storage 205 SATA 111 controlling CLI command output 295 conventions for command parameter tables 32 core count omreport chassis processors 59 current speed omreport chassis processors 59 currents omconfig chassis 124 omreport chassis 8 D data bus width omreport chassis slots 69 default maximum warning threshold 125 default minimum warning threshold 125 defining alert actions 158 delay battery learn cycle Index 305 omconfig 282 delete virtual disk omconfig 240 288 289 delimiters data fields 153 depreciation information about 180 adding 180 dirservice omcontig preferences 154 disable enclosure alarm omconfig 275 display IDs 199 200 E enable enclosure alarm omconfig 275 enclosure omconfig storage 274 287 290 292 294 omreport storage 206 211 error checking and error messages CLI 21 error messages 21 esmlog omconfig system 163 omreport system 7 1 event name alert actions 159 omconfig system platformevents 166 306
56. gt is the enclosure number and n is the number of a temperature probe For example controller 0 enclosure 2 info temps index 1 Displays property information for all enclosures attached to the system Displays the information about the temperature probes for the specific enclosure Displays the temperature probes for the specified enclosure omreport storage Commands 207 omreport Fan Status Table 7 7 describes the syntax for the omreport fan commands Table 7 7 omreport Fan Status Commands Required Command Levels Optional name value pairs Use 1 2 3 and name value pair omreport storage Displays property enclosure information for all enclosures attached to the system controller id enclosure Displays the information lt ENCLOSUREID gt about the fans for the info fans specific enclosure where id is the controller number and ENCLOSUREID is the enclosure number For example controller 0 enclosure 2 NOTE For SCSI controllers the ID specified in enclosure lt ENCLOSUREID gt is the connector number and for Serial Attached SCSI SAS controllers ID is the connectorNumber Enclosurelndex controller id enclosure Displays the specified lt ENCLOSUREID gt fan info fans index n where id is the controller number and ENCLOSUREID is the enclosure number and n is the number of a fan For example controller 0 enclosure 2 info fans index 1 208 omreport storage Com
57. id is the controller ID as reported by the omreport storage controller command Example Syntax To create the encryption key for the controller type omconfig storage controller action enablelkm controller 1 keyid Dell_123 passphrase Del1_123 scrow yes filepath C escrow xml K NOTE If you set escrow yes specify the escrow file path omconfig Rekey LKM Controller Use the following omconfig storage command syntax to re key the encryption key in LKM mode for the controller Complete Syntax omconfig storage controller action rekeylkm controller id keyid lt keyid gt passphrase lt passphrase string gt escrow yes filepath lt Absolute path to the escrow file gt where id is the controller ID as reported by the omreport storage controller command Example Syntax To re key the encryption key for the controller type omconfig storage controller action rekeylkm controller 1 272 omconfig storage Commands omconfig Convert Multiple RAID to Non RAID Use the following omconfig storage command syntax to convert multiple RAID to non RAID on the given controller Complete Syntax omconfig storage controller action convertraidtononraid controller id pdisk lt PDISKID gt where id is the controller ID as reported by the omreport storage controller command and PDISKID is specified as pdisk connector enclosureID targetID connector targetID Example Syntax To convert multiple RAID to non RAID on the
58. if the device is disabled Intrusion Displays whether the intrusion check is enabled or disabled during system boot Mouse Displays whether the mouse is enabled or disabled Optical Drive Controller Displays whether the optical drive controller is enabled or disabled Parallel port address Displays whether the address is located on LPT 1 LPT2 and LPT3 or if it is disabled Parallel port mode Displays the setting associated with the parallel port Primary SCSI Displays whether the device is on or off omreport Viewing System Status Using the Instrumentation Service Table 3 3 BIOS Setup Parameters on Systems Prior to Dell PowerEdge yx2x System continued Parameters Description RAID on motherboard Displays whether RAID on motherboard is detected as a RAID device a SCSI device or if the device is disabled during system boot RAID Channel A Displays whether RAID on motherboard Channel A is detected as a RAID device or a SCSI device RAID Channel B Displays whether RAID on motherboard Channel B is detected as a RAID device or a SCSI device SATA Serial Port 1 Displays whether serial port is mapped to a COM port a COM port 1 a COM port 3 a COM1 BMC a BMC Serial a BMC NIC a BMC RAC or is disabled Serial Port 2 Displays whether serial port 2 is mapped to a COM port a COM port 2 a COM port 4 or is disabled Speaker Displays whether the speaker is o
59. index 4 warnthresh 325 unit btuphr When you issue the command and the system sets the values you specify the following message is displayed Power consumption probe warning threshold s set successfully omconfig chassis remoteaccess or omconfig mainsystem remoteaccess Use the omconfig chassis remoteaccess or omconfig mainsystem remoteaccess command to configure Remote access on a local area network LAN The serial port for BMC or RAC whichever is installed The BMC or RAC on a serial over LAN connection Terminal settings for the serial port Advanced settings for a serial over LAN connection Information on a BMC or RAC user Information on IPv6 and IPv4 interfaces K NOTE Enter the user ID to configure user information Type 136 omconfig chassis remoteaccess or omconfig mainsystem remoteaccess l omconfig Managing Components Using the Instrumentation Service The output of the omconfig chassis remoteaccess or omconfig mainsystem remoteaccess command lists each of the available configurations The following table lists the valid parameters Table 4 12 Parameters of omconfig chassis remoteaccess or omconfig mainsystem remoteaccess name value pair 1 name value pair 2 config Description config ipvt enable disable additional ipv6 enable disable enable IPv4 stack to load on iDRAC disable IPv4 stack to flush on iDRAC enable Enables IPv6 stack to load on iDRAC disab
60. is detected A failure event occurs when any temperature probe inside a chassis reads a temperature in degree Celsius that exceeds the maximum temperature failure threshold value 174 omconfig Managing Components Using the Instrumentation Service Example Thermal Shutdown Commands To trigger a thermal shutdown when a temperature probe detects a failure event type omconfig system thrmshutdown severity failure or omconfig servermodule thrmshutdown severity failure To disable thermal shutdown so that an administrator has to initiate an omconfig system shutdown type omconfig system thrmshutdown severity disabled or omconfig servermodule thrmshutdown severity disabled omconfig Managing Components Using the Instrumentation Service 175 176 omconfig Managing Components Using the Instrumentation Service omconfig system or servermodule assetinfo Editing Cost of Ownership Values The omconfig system assetinfo or omconfig servermodule assetinfo command helps you to edit a comprehensive set of parameters that make up the total cost of ownership of the system This section explains the parameters that are reported and configured under the omconfig system assetinfo or omconfig servermodule assetinfo command Using the omconfig system assetinfo or omconfig servermodule assetinfo command you can set governing values for configurable objects Examples of assetinfo configuration capabilities include setting values for
61. log on physical disk 3 on connector 0 of controller 1 e For SAS controllers omconfig storage pdisk action exportlog controller 1 pdisk 0 2 3 omconfig Convert RAID to Non RAID Use the following omconfig command to convert RAID to non RAID on a physical disk Complete Syntax omconfig storage pdisk action convertraidtononraid controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller K NOTE To convert multiple RAID to non RAID on a given controller use omconfig storage controller action convertraidtononraid command For more information see omconfig Convert Multiple RAID to Non RAID on page 273 230 omconfig storage Commands Example Syntax To convert RAID to non RAID on physical disk 3 on connector 0 of controller 1 e For SAS controllers omconfig storage pdisk action raidtononraid controller 1 pdisk 0 2 3 K NOTE On a SAS controller the physical disk resides in enclosure 2 omconfig Convert Non RAID to RAID Use the following omconfig command to convert non RAID to RAID on a physical disk Complete Syntax omconfig storage pdisk action convertnonraidtoraid controller id pdisk lt PDISKID gt where id is the controller ID The
62. n gt asset is devalued or depreciated unit months Unit in months or years years 180 omconfig system or servermodule assetinfo Editing Cost of Ownership Values Example Commands for Adding Depreciation Information To provide a value for a depreciation parameter type a command of the form omconfig system assetinfo info depreciation lt name value pair 2 gt or omconfig servermodule assetinfo info depreciation lt name value pair 2 gt For example type omconfig system assetinfo info depreciation method straightline Or omconfig servermodule assetinfo info depreciation method straightline The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to name value pair 1 For an example see Example Commands for Adding Acquisition Information on page 179 Adding Extended Warranty Information Use the omconfig system extwarranty or omconfig servermodule extwarranty command to assign values for extended warranty information A warranty is a contract between the manufacturer or dealer and the purchaser of a system The warranty identifies the components that are covered for repair or replacement for a specified length of time or usage The extended warranty comes into force after the original warranty expires For details on how to edit
63. omconfig mainsystem leds name value pair1 name value pair 2 Description index lt n gt NA Number of the chassis where the LED resides defaults to chassis 0 main system chassis led fault severity warning Select to flash the LED either when a critical warning event occurs or when a critical event occurs led hdfault action clear Sets the number of faults for the hard drive back to zero 0 led identify flash off on Sets the chassis identification LED to off or on Set the time out value for the LED time out lt n gt a to flash for a specified number of seconds omconfig chassis memorymode or omconfig mainsystem memorymode Use the omconfig chassis memorymode or omconfig mainsystem memorymode command to specify the redundancy mode to use for the system memory in case of memory errors omconfig Managing Components Using the Instrumentation Service 129 Redundant memory enables a system to switch to other available memory modules if unacceptable errors are detected in the modules that the system is currently using The omconfig chassis memorymode or omconfig mainsystem memorymode command allows you to disable redundancy when you disable redundancy you instruct the system not to switch to other available memory modules when the module the system is using begins to encounter errors To enable redundancy choose among spare mirror RAID and DDDC Spare mode disables a bank of system memory in whi
64. omreport storage controller to display the controller Ds and then type omreport storage pdisk controller id to display the IDs for the physical disks attached to the controller For example the controller id parameter is specified as controller 1 connector id Indicates the connector ID as reported by the omreport command To obtain this value type omreport storage controller to display the controller IDs and then type omreport storage connector controller id to display the IDs for the connectors attached to the controller For example the connector id parameter is specified as connector 2 vdisk id Indicates the virtual disk ID as reported by the omreport command To obtain this value type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller id to display the IDs for the virtual disks on the controller For example the vdisk id parameter is specified as vdisk 3 enclosure lt ENCLOSUREID gt Indicates a particular enclosure by specifying either enclosure connector or enclosure connector enclosureID To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage enclosure controller idto display the IDs for the enclosures attached to the controller pdisk lt PDISKID gt Indicates a particular physical disk by specifying either connector targetID or connector enclosureID targetID To obta
65. or omreport mainsystem remoteaccess omreport chassis slots or omreport mainsystem slots 0 000008 omreport chassis temps or omreport mainsystemtemps 000 omreport chassis volts or omreport mainsystem volts 0 0000 omreport system Commands or omreport servermoduleCommands omreport system or omreport servermodule Commands for ViewingLogs omreport system alertaction or omreport servermodule alertaction omreport system assetinfo or omreport servermodule assetinfo omreport system events or omreport servermodule events omreport system operatingsystem or omreport servermodule operatingsystem omreport system pedestinations or omreport servermodule pedestinations omreport system platformevents or omreport servermodule platformevents Contents omreport system recovery or omreport servermodulerecovery omreport system shutdown or omreport servermodule shutdown omreport system summary or omreport servermodule summary omreport system thrmshutdown or omreport servermodule thrmshutdown omreport system version or omreport servermodule version omreport preferencesCommands 4 omconfig Managing Components Using the Contents Instrumentation Service Conventions for Parameter Tables
66. pairs Use omreport storage pdisk controller id where id is the controller number For example controller 0 vdisk id where id is the virtual disk number For example vdisk 1 cachecade id where id is the cachecade number For example cachecade 1 connector id where id is the connector number For example connector 1 pdisk connectorID targetID connectorID enclosureID slotID where connectorID targetID is the connector number and the physical disk number and connectorID enclosurelD slotID is the connector number enclosure number and slot number For example pdisk 0 2 or pdisk 0 1 2 Displays all physical disks attached to the specified controller NOTE If a physical disk was replaced by another disk as part of the replace member operation the state of the physical disk is displayed as Replacing Displays all physical disks included in the specified virtual disk on the controller Displays all physical disks included in the specified cachecade on the controller Displays all physical disks attached to the specified connector on the controller Displays the specified physical disk on the specified connector on the controller omreport storage Commands 203 omreport Virtual Disk Status Table 7 3 describes the syntax for the omreport virtual disk commands Table 7 3 omreport Virtual Disk Commands Required Command Optional name value
67. pairs Use Levels 1 2 3 omreport storage vdisk Displays property information for all virtual disks on all controllers controller id Displays all virtual disks on where id is the controller the specified controller number For example controller 0 controller id vdisk id Displays the specified virtual where id is the controller disk on the controller number and the virtual disk number For example controller 0 vdisk 1 204 omreport storage Commands omreport Controller Status Table 7 4 describes the syntax for the omreport controller commands Table 7 4 omreport Controller Commands Required Optional name value pairs Use Command Levels 1 2 3 omreport Displays property information for all storage controllers attached to the system controller controller id Displays the specified controller and all attached components such as enclosures where id is the i virtual disks physical disks and so on controller number For example controller 0 controller id Displays the locked foreign configuration info foreignkeyids information for import or clear operations controller id Displays the empty and occupied slot details info pdslotreport of enclosures in the controller NOTE This command is not supported on Blackplane SCSI and SWRAID controllers omreport storage Commands 205 omreport Enclosure Status Table 7 5 describes the syntax for the omreport enclosure commands
68. performs when the system detects a removable flash media event removableflashmediawarn Sets actions that Server Administrator performs when a removable flash media warning is displayed omconfig Managing Components Using the Instrumentation Service 167 Table 4 26 Parameters of omconfig system platformevents continued Event Name Description event removableflashmediafail Sets actions that Server Administrator performs when a removable flash media fails event tempfail Sets action or enables or disables alert generation when a temperature probe detects that the temperature is either too high or low for proper operation event voltfail Sets action or enables or disables alert generation when a voltage probe detects that the voltage is too low for proper operation event intdualsdcardcritical Sets actions that Server Administrator performs when an internal dual SD card critical event occurs event intdualsdcardwarn Sets actions that Server Administrator performs when an internal dual SD card warning is displayed event intdualsdcardabsent Sets actions that Server Administrator performs when an internal dual SD card is not available event intdualsdcardredunlost Sets actions that Server Administrator performs when the redundancy of an internal dual SD card is lost event watchdogasr Enables or disables alert generation configured by the ASR when the syst
69. product defined in omprv32 ini For Server Administrator the product name is omsa Therefore for a computer named myOmsa running Server Administrator the default name is myOmsa omsa This is the name of Server Administrator defined in Active Directory by using the snap in tool This name must match the name for the application object in Active Directory in order to find user privileges K NOTE This command is applicable only on systems running the Windows operating system Table 4 17 lists the valid parameters for the command Table 4 17 Active Directory Service Configuration Parameters name value pair Description prodname lt text gt Specifies the product to which you want to apply the Active Directory configuration changes prodname refers to the name of the product defined in omprv32 ini For Server Administrator it is omsa enable lt true true Enables Active Directory service authentication support false gt and the Active Directory Login option on the login page false Disables Active Directory service authentication support and the Active Directory Login option on the login page If the Active Directory Login option is not present you can only login to the local machine accounts adprodname Specifies the name of the product as defined in the Active lt text gt Directory service This name links the product with the Active Directory privilege data for user authentication 154 omconf
70. setting lt integer gt setting lt string gt setting lt string gt setting lt string gt setting lt string gt setting lt integer gt setting lt string gt setting lt string gt setting lt string gt setting lt string gt setting lt integer gt setting lt string gt setting Enabled Disabled setting lt string gt setting Single All Dual Quad 1 2 4 6 8 10 12 14 16 setting lt string gt setting Enabled Disabled setting Enabled Disabled setting Enabled Disabled setting InputOutput Compute omconfig Managing Components Using the Instrumentation Service Table 4 4 BIOS Setup Settings on PowerEdge yx2x Systems continued Group name value pair 1 attribute name value pair 2 setting Processor Settings attribute QpiSpeed setting MaxDataRate 8GTps continued 7GTps 6GTps attribute RtidSetting setting Enabled Disabled SATA Settings attribute EmbSata setting Off AtaMode attribute eSataPort1 attribute eSataPort1 Capacity attribute eSataPort1 Drive Type attribute eSataPort 1 Model attribute SataPortA attribute SataPortACapacity attribute SataPortADriveType attribute SataPortAModel attribute SataPortB attribute SataPortBCapacity attribute SataPortBDriveType attribute SataPortBModel attribute SataPortC attribute SataPortCCapacity attribute SataPortCDriveType RaidMode AhciMode se
71. type omconfig storage controller action deletesecuritykey controller 1 omconfig Set Background Initialization Rate Use the following omconfig command syntax to set the background initialization rate 264 omconfig storage Commands Complete Syntax omconfig storage controller action setbgirate controller id rate lt 0 to 100 gt where id is the controller ID as reported by the omreport storage controller command Example Syntax To set the background initialization rate to 50 on controller 1 type omconfig storage controller action setbgirate controller 1 rate 50 omconfig Set Reconstruct Rate Use the following omconfig command syntax to set the reconstruct rate Complete Syntax omconfig storage controller action setreconstructrate controller id rate lt 0 to 100 gt where id is the controller ID as reported by the omreport storage controller command Example Syntax To set the reconstruct rate to 50 on controller 1 type omconfig storage controller action setreconstructrate controller 1 rate 50 omconfig Set Check Consistency Rate Use the following omconfig command syntax to set the check consistency rate omconfig storage Commands 265 Complete Syntax omconfig storage controller action setcheckconsistencyrate controller id rate lt 0 to 100 gt where id is the controller ID as reported by the omreport storage controller command Example Syntax To set the check consistency rate to
72. warranty values see Adding Warranty Information on page 193 omconfig system or servermodule assetinfo Editing Cost of Ownership Values 181 Table 5 4 lists the valid parameters for the command Table 5 4 Parameters of omconfig system assetinfo info extwarranty or omconfig servermodule assetinfo info extwarranty Command Command Level Command Name Value Name Value Level 1 2 Level 3 Pair 1 Pair 2 Description omconfig system or servermodule assetinfo info extwarranty cost lt cost gt enddate lt enddate gt provider lt provider gt startdate lt startdate gt Cost of the extended warranty service Date the extended warranty agreement ends Business entity that provides the extended warranty service Date the extended warranty service begins Example Command for Adding Extended Warranty Information To provide a value for an extended warranty parameter type a command of the form omconfig system assetinfo info extwarranty lt name value pair 2 gt or omconfig servermodule assetinfo info extwarranty lt name value pair 2 gt For example type omconfig system assetinfo info extwarranty enddate 012503 Or omconfig servermodule assetinfo info extwarranty enddate 012503 The following message is displayed Asset information set successfully 182 omconfig system or servermodule assetinfo Editing Cost of Ownership Values You can type more than one omconfig system
73. 1 lom 2 Configures the failover network to lom 2 lom 3 Configures the failover network to lom 3 lom 4 Configures the failover network to lom 4 all Configures the failover network to all loms NOTE The failovernw option is supported on PowerEdge yx2x systems onwards Configure both primarynw and failovernw to setthe nicselection The primarynw and failovernw options cannot have the same value NOTE Failovernw requires license to configure the ports If the appropriate license is not installed or has expired the system displays an error message For more information see 7he Dell Licensing Management Guide at dell com support manuals ip Sets the IP address if you have selected static as the IP address source for the BMC LAN interface Sets a subnet mask if you have selected static as the IP address source for the BMC LAN interface Gateway Sets a gateway address if you have selected static as the IP address source for the BMC LAN interface omconfig Managing Components Using the Instrumentation Service 139 Table 4 12 Parameters of omconfig chassis remoteaccess or omconfig mainsystem remoteaccess continued name value pair 1 name value pair 2 Description config ipsource static dhcp static Static if the IP address of the systemsoftware BMC LAN interface is a fixed assigned IP address dhcp DHCP if the source of the IP address of the BMC LAN interface is the dynamic host configur
74. 2 3 K NOTE On a SAS controller the physical disk resides in enclosure 2 omconfig Online Physical Disk Use the following omconfig command syntax to bring an offline physical disk back online Complete Syntax omconfig storage pdisk action online controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk omconfig storage Commands 223 To obtain these values type omreport storage controller to display the controller Ds and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To bring physical disk 3 on connector 0 of controller 1 back online e For SCSI SATA and ATA controllers omconfig storage pdisk action online controller 1 pdisk 0 3 For SAS controllers omconfig storage pdisk action online controller 1 pdisk 0 2 3 K NOTE On a SAS controller the physical disk resides in enclosure 2 omconfig Assign Global Hot Spare Use the following omconfig command syntax to assign a physical disk as a global hot spare Complete Syntax omconfig storage pdisk action assignglobalhotspare controller id pdisk lt PDISKID gt assign yes where id is the controller ID The lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display th
75. B mouse keyboard and so on Base I O Address is the starting I O address expressed in hexadecimal IRQ Level is a hardware interrupt on a system The hardware interrupt signals the system s CPU that an event has started or ended in a peripheral component such as a modem or printer When communicated over a peripheral component interconnect card the IRQ level is a standard way to identify the type of device that is sending the interrupt request Connector Type refers to the type of plug or cable and plug that connects two devices together in this case the type of connector that attaches an external device to a system There are many connector types each designed to connect a different device type to a system Examples include DB 9 Male AT Access Bus PS 2 and so on Maximum Speed is the port speed Port speed refers to the data transmission rate of an input output channel measured in numbers of bits per second Serial ports usually have a maximum speed of 115 Kbps and USB version 1 x ports have a maximum speed of 12 Kbps omreport chassis processors or omreport mainsystem processors Use the omreport chassis processors or omreport mainsystem processors command to view properties of the system s processors Server Administrator displays values for the following fields Index Status Connector Name Processor Brand Processor Version Current Speed State and Core Count Index is the processor number Status is the curren
76. B Port Displays whether the internal USB is enabled or disabled number NOTE Server Administrator may not display the USB sequence number if there is only one USB port on the system omreport Viewing System Status Using the Instrumentation Service 45 Table 3 3 BIOS Setup Parameters on Systems Prior to Dell PowerEdge yx2x System continued Parameters Description Operating System Watchdog Timer Displays whether the operating system watchdog timer is enabled or disabled HT Assist Displays the status of the probe filter chipset option Internal SD Card Displays whether the internal SD card is enabled or disabled Bezel Displays whether the bezel removal intrusion check during system reboot is enabled or disabled Console Redirection Displays whether the BIOS screen is redirected over a particular serial port or if it is turned off Diskette Displays whether the diskette is disabled auto enabled or read only Demand Based Power Management DBS Displays whether DBS is enabled or disabled on the system Embedded Hypervisor Displays whether the embedded hypervisor is enabled or disabled IDE Displays whether the drive is enabled or disabled IDE Primary Drive 0 Displays whether the device is automatically detected and enabled or if the device is disabled IDE Primary Drive 1 Displays whether the device is automatically detected and enabled or
77. Command Levels Command level 1 Command level 2 Command level 3 Use omconfig Specifies the command storage Indicates the Server Administrator service in this case storage management that implements the command pdisk Specifies the type of object on which the command operates Following the command levels the omreport and omconfig command syntax may require one or more name value pairs The name value pairs specify exact objects such as a specific physical disk or options such as blink or unblink that the command implements For example the following omconfig command syntax for blinking a physical disk has three levels and three name value pairs omconfig storage pdisk action blink controller id pdisk lt PDISKID gt where PDISKID lt connector enclosureID targetID connector targetID gt In this example the id in cont roller id is the controller number such that controller 1 is specified as controller 1 Syntax for Required Optional and Variable Command Elements The omreport and omconfig commands have multiple name value pairs These name value pairs may include required optional and variable parameters Table 6 2 describes the syntax used to indicate these parameters 198 Using the Storage Management Service Table 6 2 Syntax For of Parameters Syntax Description controller id Indicates the controller ID as reported by the omreport storage controller command To obtain these values type
78. Cost of Ownership Values 193 Table 5 12 Parameters of omconfig system assetinfo info warranty or omconfig servermodule assetinfo info warranty Command Command Command Name Value Name Value Description Level 1 Level 2 Level3 Pair1 Pair 2 omconfig system or servermodule assetinfo info warranty cost Cost of the warranty lt cost gt service duration Number of days or lt duration gt months that the warranty is in force enddate Date the warranty lt enddate gt agreement ends unit days Whether the number months for duration refers to days or months Example Command for Adding Warranty Information To provide a value for a warranty parameter type a command of the form omconfig system assetinfo info warranty lt name value pair 2 gt or omconfig servermodule assetinfo info warranty lt name value pair 2 gt For example type omconfig system assetinfo info warranty unit days or omconfig servermodule assetinfo info warranty unit days The following message is displayed Asset information set successfully 194 omconfig system or servermodule assetinfo Editing Cost of Ownership Values You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to name value pair 1 For an example see Example Commands for Adding Acquisition Information on page 179 omconfig system or servermodu
79. Dell OpenManage Server Administrator Version 7 1 2 Command Line Interface Guide Notes and Cautions K NOTE A NOTE indicates important information that helps you make better use of your computer VAN CAUTION A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed Information in this publication is subject to change without notice 2013 Dell Inc All rights reserved Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc is strictly forbidden Trademarks used in this text Dell PowerEdge and OpenManage are trademarks of Dell Inc Microsoft Windows Active Directory MS DOS and Windows Server are either trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries SUSE is a registered trademark of Novell Inc in the United States and other countries Red Hat and Red Hat Enterprise Linux are registered trademarks of Red Hat Inc in the United States and other countries Intel Pentium and Itanium are registered trademarks and Intel386 is a trademark of Intel Corporation in the United States and other countries AMD AMD Opteron AMD V and AMD PowerNow are trademarks of Advanced Micro Devices Inc VMware is a registered trademark and ESX Server is a trademark of VMware Inc in the United States and or other jurisdictions Citrix Xen XenServer
80. For example spanlength 3 For RAID 10 on SAS controllers with firmware version 6 1 and later spanlength is optional Also you can now specify the spanlength as an even number with a maximum of 8 spans with 32 physical disks each For example omconfig storage controller action createvdisk controller 1 raid r10 size min pdisk H a E O Dd Te 3 Deh es 64 th se 7 pall ei Bt 1 sO spanlength 4 260 omconfig storage Commands Example Syntax You can create a RAID 5 virtual disk of 500MB with a stripe size of 16 KB ona PERC 3 QC controller The name of the virtual disk is vd1 and it resides on connector 0 of controller 1 Because the virtual disk is a RAID 5 it requires at least three physical disks In this example you specify four physical disks These are physical disks 0 through 3 The virtual disk has read ahead write through caching and cache I O policies To create a virtual disk omconfig storage controller action createvdisk controller 1 raid r5 size 500m pdisk 0 0 0 1 0 2 0 3 stripesize 16kb cachepolicy c readpolicy ra writepolicy wt The only parameters that require specification are for the controller RAID level virtual disk size and physical disk selection Storage Management supplies default values for all other unspecified parameters For more information on read write and cache policies are supported by the controller see the Dell OpenManage Online Help omconfig Set Controller Rebuild Rate Use the followi
81. Index event notification configuring 168 index 171 severity 170 source 169 type 169 events alert actions 159 160 classified by component type 76 omcontig system 168 omreport system 74 SNMP 37 94 168 example help commands 27 extended warranty information 181 external name omreport chassis ports 58 extwarranty omcontig system 181 F failure messages 22 fan status omreport 208 fans omcontig chassis 124 omreport chassis 50 firmware omreport chassis 50 format virtual disk 241 formatting CLI command output 299 frontpanel omcontig chassis 126 omreport chassis 5 G globalinfo omcontig storage 283 omreport storage 212 H help levels of 28 hot spare 239 import foreign configuration omconfig 267 268 import secure foreign configuration omcontig 267 index omreport chassis slots 69 info omcontig chassis 128 omreport chassis 52 initialize virtual disk omconfig 222 236 introduction 17 intrusion omreport chassis 53 IP address alert destinations 164 IRQ level omreport chassis ports 58 L lease information 183 leds omcontig chassis 129 omreport chassis 54 levels of help for a CLI command 28 maintenance information 184 adding 184 maximum speed omreport chassis ports 58 maximum warning threshold 151 memory arrays 35 87 omreport chassis 55 memorymode omcontig chassis 129 minimum warning thr
82. Managing Components Using the Instrumentation Service 131 omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement Use the omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement command to configure power cap and manage profiles that control power utilization K NOTE This command is valid only on systems prior to PowerEdge yx2x systems Table 4 10 lists the valid parameters for the command Table 4 10 Parameters of omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement name value pair 1 name value pair 2 Description config budget cap lt value gt Sets the threshold value for power budget NOTE From PowerEdge yx2x system onwards power budget requires license to configure power cap If the appropriate license is not installed or has expired the system displays an error message For more information see The Dell Licensing Management Guide on dell com support manuals setting enable enable Enables powercap settings disable disable Disables powercap settings unit watt btuphr watt Configure the unit in Watts percent btuphr Configure the unit in BTU hr percent Configure the unit in percentage 132 omconfig Managing Components Using the Instrumentation Service Table 4 10 Parameters of omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement continued name value pair 1 name value pair 2 Description config profile NOTE
83. MemSpeed attribute SysMemType attribute SysMemVolt attribute VideoMem setting OptimizerMode SpareMode MirrorMode AdvEccMode SpareWithAdvEccMode setting AutoVolt Volt15V NOTE Volt15V represents 1 5 Volt setting Enabled Disabled setting Enabled Disabled setting Enabled Disabled setting lt string gt setting lt string gt setting lt string gt setting lt string gt setting lt string gt Miscellaneous Settings 116 attribute AssetTag attribute Characterization attribute ErrPrompt attribute NumLock attribute ReportKbdErr setting lt string gt setting Enabled Disabled setting Enabled Disabled setting 0n Off setting Report NoReport omconfig Managing Components Using the Instrumentation Service Table 4 4 BIOS Setup Settings on PowerEdge yx2x Systems continued Group name value pair 1 name value pair 2 attribute setting Miscellaneous attribute SystemUefiShell setting Enabled Disabled Settings continued One Time Boot attribute OneTimeBootMode attribute OneTimeBootSeqDev attribute OneTimeHddSeqDev attribute OneTimeUefiBootSeqDev setting Disabled OneTimeBootSeq OneTimeHddSeq OneTimeUefiBootSeq OneTimeCustomBootSegStr OneTimeCustomHddSedStr OneTimeCustomUefiBootSegStr sequence aliasnamel aliasname2 aliasnameN sequence aliasnamel aliasname2 aliasnameN sequence aliasnamel aliasname2 al
84. NOTE You cannot change threshold values on ESM3 and PowerEdge x8xx systems 96 omconfig Managing Components Using the Instrumentation Service Table 4 2 omconfig Command Level 1 Level 2 and Level 3 continued Command Command Command Level3 User Use Level 1 Level 2 Privilege Required volts PA Sets warning threshold values default or a specific value NOTE You cannot change threshold values on ESM3 and PowerEdge x8xx systems storage See Using the Storage Management Service on page 197 Help With the omconfig Command Use the omconfig command to get a list of the available commands for omconfig Use omconfig lt command level 2 gt to get help on the about chassis preferences and system s level 2 commands The following information on omconfig system applies equally to getting help for the omconfig chassis command Use the omconfig system command to get a list of the available commands for omconfig system Use the omconfig preferences command to get a list of the available commands for omconfig preferences such as cdvformat which is the custom delimiter format cdv Type the following command to display the list of delimiter values for the cdv omconfig preferences cdvformat omconfig Managing Components Using the Instrumentation Service 97 Use a command of the form omconfig system lt command level 3 gt to get a list of the parameters you must use to execute a particu
85. RevryDelay Random attribute setting lt integer gt AcPwrRevryUserDelay attribute AesNi attribute BiosUpdateControl attribute IntelTxt attribute NmiButton attribute PasswordStatus attribute PwrButton attribute SetupPassword attribute SysPassword attribute TcmActivation attribute TcemClear attribute TemSecurity attribute TpmActivation attribute TpmClear attribute TpmSecurity setting Enabled Disabled setting Unlocked Limited Locked setting 0n Off setting Enabled Disabled setting Locked Unlocked setting Enabled Disabled setting lt string gt setting lt string gt setting NoChange Activate Deactivate CAUTION Clearing the TPM will cause loss of all keys in the TPM This could affect booting of the operating system setting Yes No setting On Off setting NoChange Activate Deactivate CAUTION Clearing the TPM will cause loss of all keys in the TPM This could affect booting of the operating system setting Yes No setting Off OnPbm OnNoPbm omconfig Managing Components Using the Instrumentation Service 123 Table 4 4 BIOS Setup Settings on PowerEdge yx2x Systems continued Group name value pair 1 name value pair 2 attribute setting UEFI Boot Settings attribute UefiBootSeq sequence aliasnamel aliasname2 aliasnameN omconfig chassis currents or omconfig mainsystem currents K NOTE This command is no longer available throu
86. Security Access displays if the front panel encryption access information is set to View Modify or Disable The Front Panel LCD Information displays information such as service tag remote indication status and so on omreport chassis fru or omreport mainsystem fru Use the omreport chassis fru or omreport mainsystem fru command to view FRU information When you type omreport chassis fru or omreport mainsystem fru Server Administrator displays a summary of the system s FRU information This information is available in the Server Administrator GUI SNMP and Common Information Model and is primarily used to support troubleshooting activities omreport Viewing System Status Using the Instrumentation Service 51 omreport chassis hwperformance or omreport mainsystem hwperformance Use the omreport chassis hwperformance or omreport mainsystem hwperformance command to view the status and cause for the system s performance degradation When you type omreport chassis hwperformance or omreport mainsystem hwperformance Server Administrator displays a summary of the system s hardware performance degradation information K NOTE This command is applicable only to selected Dell yxOx systems that support PMBus Depending on the system s configuration you may notice the following output Hardware Performance Index 0 Probe Name System Board Power Optimized Status Normal Cause N A omreport chassis in
87. Service 107 Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems continued name value pair1 name value pair 2 attribute setting Description attribute nicl setting enabled enabledwithpxe disabled enabledonly enablednonepxe enabledwithiscsi enabled Enables the first NIC during system boot enabledwithpxe Enables the first NIC during system boot with PXE on if the system has PXE disabled Disables the first NIC during system boot enabledonly Enables the first NIC during system boot with PXE off if the system has PXE enablednonepxe Enables the first NIC during system boot with PXE off if the system has PXE enabledwithiscsi Enables the first NIC during system boot with iSCSI on if the system has iSCSI 108 attribute nic2 setting enabled enabledwithpxe disabled enabledonly enablednonepxe enabledwithiscsi enabled Enables the second NIC during system boot enabledwithpxe Enables the second NIC during system boot with PXE on if the system has PXE disabled Disables the second NIC during system boot enabledonly Enables the second NIC during system boot with PXE off if the system has PXE enablednonepxe Enables the second NIC during system boot with PXE off if the system has PXE enabledwithiscsi Enables the second NIC during system boot with iSCSI on if the system has iSCSI omconfig Managing Compo
88. The following fields are defined for a cache present on a particular microprocessor If the cache is internal to the processor the fields do not appear in the cache report e Speed e Cache Device Supported Type e Cache Device Current Type e External Socket Name K NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator Fields Reported for Each Cache on a Particular Processor The following fields are displayed for each cache on a particular processor Status reports whether a specific cache on the processor is enabled or disabled Level refers to a primary or secondary cache Primary level cache is a memory bank built into the processor Secondary level cache is a staging area that feeds the primary cache A secondary level cache is built into the processor or resides in a memory chipset outside the processor The internal processor cache is referred to as a Level 1 or L1 L2 cache is the external cache in a system with an Intel Pentium processor and it is the second level of cache that is accessed The names L1 and L2 are not indicative of where the cache is physically located internal or external but describe which cache is accessed first L1 therefore internal Speed refers to the rate at which the cache can forward data from the main memory to the processor Max Size is the maximum amount of memory t
89. a Failure K NOTE Storage Controller Battery Warning and Storage Controller Battery Failure events are not available on Blade systems K NOTE System Power Probe Warning is not applicable to Blade systems omreport system assetinfo or omreport servermodule assetinfo Use the omreport system assetinfo or omreport servermodule assetinfo command to see cost of ownership data for the system such as acquisition depreciation and warranty information To set any of these fields use the omconfig system assetinfo or omconfig servermodule assetinfo command For more information see omconfig system or servermodule assetinfo Editing Cost of Ownership Values on page 177 omreport system events or omreport servermodule events Use the omreport system events or omreport servermodule events command to view the currently enabled or disabled SNMP traps This command displays a summary of each component in the system for which events are generated For each component the report shows which severities are set to report and which severities are set not to report Type omreport system events or omreport servermodule events 74 omreport Viewing System Status Using the Instrumentation Service The following is an example output for a few components Current SNMP Trap Configuration Settings Enable Informational Warning and Critical Disable None Power Supplies Settings Enable Informational Warning and Critical Dis
90. a corruption Complete Syntax omconfig storage vdisk action enablefluidcache controller id vdisk id devicename lt string gt cachepolicy lt wb wt gt where id is the controller ID and virtual disk ID as reported by the omreport command lt string gt is the device name of the virtual disk wb is writeback and wt is writethrough To obtain the values for controller ID and virtual disk ID type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Example Syntax To enable fluid cache on virtual disk 4 on controller 1 type omconfig storage vdisk action enablefluidcache controller 1 vdisk 4 devicename dev sdb cacachepolicy wb omconfig storage Commands 247 omconfig Disable Fluid Cache on Virtual Disk Use the following omconfig command syntax to disable fluid cache for the specified virtual disk Complete Syntax omconfig storage vdisk action disablefluidcache controller id vdisk id devicename lt string gt where id is the controller ID and virtual disk ID as reported by the omreport command and lt string gt is the device name of the virtual disk To obtain the values for controller ID and virtual disk ID type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the
91. a value for a support parameter type a command of the form omconfig system assetinfo info support lt name value pair 2 gt or omconfig servermodule assetinfo info support lt name value pair 2 gt For example type omconfig system assetinfo info support outsourced true Or omconfig servermodule assetinfo info support outsourced true omconfig system or servermodule assetinfo Editing Cost of Ownership Values 191 192 The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to name value pair 1 For an example see Example Commands for Adding Acquisition Information on page 179 Adding System Information System information includes the primary user of the system the phone number for the primary user and the location of the system Table 5 11 lists the valid parameters for adding system information Table 5 11 servermodule assetinfo info system Parameters of omconfig system assetinfo info system or omconfig Command Command Command Name Name Value Pair 2 Description Level 1 Level 2 Level 3 Value Pair 1 omconfig system or servermodule assetinfo info system location lt text gt Location of the system primaryphone Phone number of lt n gt the primary user of the system primaryuser Primary user o
92. able None Settings Enable Critical Disable Informational Warning and Critical Removable Flash Media Settings Enable Informational Warning and Critical Disable None The full report lists the settings for all components in the system for which events are generated To view the status for components of a specific type use the omreport system events type lt component name gt or omreport servermodule event type lt component name gt command This command displays a summary of each component in the system for which events are generated Table 3 7 lists the events displayed for various component types K NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator omreport Viewing System Status Using the Instrumentation Service 75 Table 3 7 System Events by Component Type name value pair Description type accords Reports events for AC power cords type battery Reports events for batteries type fanenclosures Reports events for fan enclosures type fans Reports events for fans type intrusion Reports events for chassis intrusion type log Reports events for logs type memory Reports events for memory type powersupplies Reports events for power supplies type redundancy Reports events for redundancy type systempower Reports events for system power type temps
93. able to selected Dell yx0x systems that support PMBus only K NOTE Power monitoring requires license to configure the power budget information If the appropriate license is not installed or has expired the system displays an error message For more information see 7he Dell Licensing Management Guide at dell com support manuals Default Warning Thresholds K NOTE Sensor managing capabilities vary across systems To set both the upper and lower power consumption probe warning threshold values to the recommended default value type omconfig chassis pwrmonitoring config probe index 0 warnthresh settodefault or omconfig mainsystem pwrmonitoring config probe index 0 warnthresh settodefault K NOTE You cannot default one value and set another If you default the minimum warning threshold value you are also selecting the default value for the maximum warning threshold value omconfig Managing Components Using the Instrumentation Service 135 Specify a Value for Warning Thresholds If you prefer to specify values for the power consumption probe warning thresholds you must specify the number of the probe you are configuring and the warning threshold value Configure the values to display either in BTU hr or Watts In the following example the probe that is being configured is probe 4 omconfig chassis pwrmonitoring config probe index 4 warnthresh 325 unit watt Or omconfig mainsystem pwrmonitoring config probe
94. able user privileges 148 omconfig Managing Components Using the Instrumentation Service Usage of dracusergroup custom The following table displays the usage of dracusergroup custom Table 4 13 Parameters of omconfig chassis remoteaccess config user id lt user id gt dracusergroup custom or omconfig mainsystem remoteaccess config user id lt user id gt dracusergroup custom name value pair1 name value pair 2 name value pair 3 Description id user id dracusergroup custom config user logindrac true false configuredrac true false configure users true false clearlogs true false executeservercom mands true false accessconsoleredir true false accessvirtualmedia true false testalerts true false true or false Enables or disables logging into DRAC true or false Enables or disables configuration of DRAC true or false Enables or disables configuration of users true or false Enables or disables log clearance true or false Enables or disables execution of server commands true or false Enables or disables access to console redirection true or false Enables or disables access to virtual media true or false Enables or disables test alerts omconfig Managing Components Using the Instrumentation Service 149 Usage of extipmiusergroup custom The following table displays the usage of extipmiusergroup custom Table 4 14 Parameters
95. ache omconfig Create EncryptionKey omconfig Change Encryption Key omconfig Delete EncryptionKey omconfig Set Background Initialization Rate omconfig Set Reconstruct Rate omconfig Set Check Consistency Rate omconfig Export the Controller Log omconfig Import Secure Foreign Configuration aaa omconfig Import Foreign Configuration omconfig Import or Recover Foreign Configuration a aaa omconfig Clear Foreign Configuration omconfig Physical Disk Power Management omconfig Set Patrol Read Mode omconfig Start Patrol Read omconfig Stop PatrolRead omconfig Create Cachecade omconfig Enable LKM Controller omconfig Rekey LKM Controller omconfig Convert Multiple RAID to Non RAID 204 273 omconfig Convert Multiple Non RAID to RAID he etre de ert BoP et Se Ft 273 Omconfig EnclosureCommands 274 omconfig Enable Enclosure Alarm 275 omconfig Disable Enclosure Alarm 275 omconfig Set Enclosure Asset Tag 276 omconfig Set Enclosure Asset Name 277 omconfig Set Temperature Probe TARESHOINS 2 son thee a ee attest h ah ett tN 277 omconfig Reset Temperature Probe Thresholds s b eua h may a aa ah 278 omconfig Set All Temperature Probe Thresholds sk ana a r a a a a a 279 omconfig Reset All Temperature Probe Thresholds iei i e a a
96. acquisition purchasecost 5000 waybil1 123456 installdate 120501 purchasedate 050601 ponum 9999 signauth John Smith expensed yes costcenter finance Or omconfig servermodule assetinfo info acquisition purchasecost 5000 waybill 123456 installdate 120501 purchasedate 050601 ponum 9999 signauth John Smith expensed yes costcenter finance The following message is displayed Asset information set successfully omconfig system or servermodule assetinfo Editing Cost of Ownership Values 179 Adding Depreciation Information Depreciation is a set of methods for computing the devaluation of the asset over time For example the depreciation of a system that is expected to have a useful life of 5 years is 20 percent Use the omconfig system assetinfo info depreciation or omconfig servermodule assetinfo info depreciation command to add details about how the system s depreciation is computed Table 5 3 lists the valid parameters for the command Table 5 3 Parameters of omconfig system assetinfo info depreciation or omconfig servermodule assetinfo info depreciation Command Command Level Command Name Value Name Value Description Level 1 2 Level3 Pair 1 Pair 2 omconfig system or servermodule assetinfo info depreciation duration Number of years or lt n gt months over which a system is depreciated method Steps and assumptions lt text gt used to compute the system s depreciation percent Portion of 100 that an lt
97. ading Statistics Measured Since Read Time Peak Reading Energy consumption Thu May 28 11 03 20 2011 Fri May 28 11 05 46 2011 5 9 KWH System Peak Power Mon May 18 16 03 20 2011 Wed May 27 00 23 46 2011 630 W System Peak Amperage Mon May 18 16 03 20 2011 Tue May 19 04 06 32 2011 Qi A NOTE Power Management features are only available for PowerEdge systems that have hot swappable power supplies and not systems that have a fixed non redundant power supply installed omreport Viewing System Status Using the Instrumentation Service omreport chassis pwrsupplies or omreport mainsystem pwrsupplies Use the omreport chassis pwrsupplies or omreport mainsystem pwrsupplies command to view properties of the system s power supplies Type omreport chassis pwrsupplies or omreport mainsystem pwrsupplies K NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable For each power supply profile in the system values display for the following fields e Status e Location e Type e Rated Input Wattage in Watts e Maximum Output Wattage e Online Status e Power Monitoring Capable omreport chassis remoteaccess or omreport mainsystem remoteaccess Use the omreport chassis remoteaccess or omreport mainsystem remoteaccess command to view general information on baseboard management controller or integrated Dell remote access controller
98. age cachecade action blink controller id cachecade id where id is the controller ID and cachecade ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller ID to display the IDs for the cachecades of the controller omconfig storage Commands 287 Example Syntax To blink the physical disk in cachecade 4 on controller 1 type omconfig storage cachecade action blink controller 1 cachecade 4 omconfig Unblink Cachecade Use the following omconfig command syntax to unblink the physical disks included in a cachecade Complete Syntax omconfig storage cachecade action unblink controller id cachecade id where id is the controller ID and cachecade ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller Ds and then type omreport storage cachecade controller ID to display the IDs for the cachecades of the controller Example Syntax To unblink the physical disks in cachecade 4 on controller 1 type omconfig storage cachecade action unblink controller 1 cachecade 4 omconfig Delete Cachecade Use the following omconfig command syntax to delete a cachecade Complete Syntax omconfig storage cachecade action deletecachecad controller id cachecade id where id is the controller ID and cachecade ID as reported by the omreport command To obt
99. aid r50 RAID 60 raid r60 RAID 1 concatenated raid rlc Concatenation raid c omconfig storage Commands 257 size lt number max min gt Parameter Required Table 8 6 indicates how to specify the size lt number max min gt parameter Table 8 6 Size Parameter size lt number max min gt Description Parameter Specification size lt n gt Use this specification to indicate a specific size for the virtual disk The virtual disk size is specified in b bytes m megabytes or g gigabytes For example size 500m indicates that the virtual disk is 500 MB size max To create a virtual disk that is the maximum size possible specify size max When creating a RAID 50 virtual disk this parameter is specified as size max size min To create a virtual disk that is the minimum size possible specify size min PDISKID lt connector enclosurelD targetID connector targetID gt Use this parameter to specify the physical disks to be included in the virtual disk When reconfiguring a virtual disk you must specify all physical disks to include in the reconfigured virtual disk The physical disk specification applies to physical disks in the original virtual disk and continues in the reconfigured virtual disk and to any new physical disks being added to the reconfigured virtual disk Some controllers allow you to remove a physical disk from a virtual disk In this case do not specify to remove the phys
100. ain these values type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller ID to display the IDs for the cachecades of the controller 288 omconfig storage Commands In some circumstances you may receive a warning message You can override this warning by using the force yes parameter In this case the syntax is as follows omconfig storage cachecade action deletecachecad controller id cachecade id force yes Example Syntax To delete cachecade 4 on controller 1 type omconfig storage cachecade action deletecachecad controller 1 cachecade 4 omconfig Resize Cachecade Use the following omconfig command syntax to resize a cachecade by adding or removing physical disks Complete Syntax omconfig storage cachecade action resize controller id cachecade id pdisk lt PDISKID gt where id is the controller ID and cachecade ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller ID to display the IDs for the cachecades of the controller Example Syntax To resize cachecade 4 use physical disks 0 through 3 on connector 0 of controller 1 e For SCSI SATA and ATA controllers omconfig storage cachecade action resize controller 1 cachecade 4 pdisk 0 0 0 1 0 2 0 3 e For SAS controllers omconfig storage cachecade action resize controller 1 ca
101. al disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To remove physical disk 3 on connector 0 of controller 1 e For SCSI SATA and ATA controllers omconfig storage pdisk action remove controller 1 pdisk 0 3 e For SAS controllers omconfig storage pdisk action remove controller 1 pdisk 0 2 3 K NOTE On a SAS controller the physical disk resides in enclosure 2 omconfig Instant Erase Secured Physical Disk Use the following omconfig command syntax to erase the data on a given encrypted disk Complete Syntax omconfig storage pdisk action instantsecureerase controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk omconfig storage Commands 221 To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To erase the data on physical disk 3 on connector 0 of controller 1 e For SCSI SATA and ATA controllers omconfig storage pdisk action instantsecureerase controller 1 pdisk 0 3 e For SAS controllers omconfig storage pdisk action remove controller 1 pdisk 0 2 3 K NOTE On a SAS controller the physical disk
102. al disks is destroyed Table 8 4 omconfig Controller Commands Required Command Levels Optional name value pairs 1 2 3 omcontig storage controller action rescan controller id action enablealarm controller id action disablealarm controller id action quietalarm controller id omconfig storage Commands 249 Table 8 4 omconfig Controller Commands continued Required Command Levels Optional name value pairs 1 2 3 action testalarm controller id action resetconfig controller id force yes action createvdisk controller id raid lt c r0 rl rlc r5 r6 r10 150 r60 gt size lt number b m g max min gt pdiskk lt PDISKID gt stripesize lt 2kb 4kb 8kb 16kb 32kb 64kb 128kb 256kb 512kb Imb gt cachepolicy lt d c gt readpolicy lt ra nra ara rc nrc gt writepolicy lt wb wt we nwe fwb gt diskcachepolicy lt disabled enabled gt name lt string gt spanlength lt n gt secureflag yes NOTE For RAID 10 on SAS controllers with firmware version 6 1 and later spanlength is an optional parameter default 2 action setrebuildrate controller id rate lt 0 to 100 gt action setchangecontrollerproperties controller lt id gt bgirate lt rate gt reconstructrate lt rate gt checkconsistencyrate lt rate gt rebuildrate lt rate gt clearredundantpath clear abortcheckconsistencyonerror lt enabled disabled gt loadbalance
103. ally enable the SATA port attribute setting on off on Enables secondary SCSI secondaryscsi off Disables secondary SCSI attribute setting default default Maps serial device 1 to COM serialportaddr alternate com1 port 1 and serial device 2 to COM com2 port 2 alternate Maps serial devicel to COM port 2 and serial device 2 to COM port 1 com Sets serial port address to COM1 com2 Sets serial port address to COM2 attribute setting off on off Disables serial communication serialcom coml com2 setting onwithconsole on Enables serial communication setting without console redirection com1l Enables serial communication setting with console redirection through COMI com2 Enables serial communication setting with console redirection through COM2 onwithconsole Enables serial communication with console redirection through COM and COM2 112 omconfig Managing Components Using the Instrumentation Service Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems continued name value pair 1 attribute name value pair 2 setting Description attribute setting off auto off Disables serial port 1 serialport com com3 auto Maps serial port 1 to a COM port bmcserial bmcnic rac comlbme com Maps serial port 1 to COM port 1 com3 Maps serial port 1 to COM port 3 bmceserial Maps serial port 1 to BMC Serial bmenic Maps serial port 1 t
104. alue type omreport storage controller to display the controller IDs and then type omreport storage battery controller ID to display the ID for the controller battery Example Syntax To delay the learn cycle for three days and 12 hours on controller 1 type omconfig storage battery action delaylearn controller 1 battery 0 days 3 hours 12 omconfig Global Commands The following sections provide the omconfig command syntax required to execute the global commands When executed these commands apply to all controllers These global commands also correspond to the global tasks provided by the Storage tree view object s Information Configuration subtab 282 omconfig storage Commands Table 8 13 omconfig Global Commands Required Command Levels 1 2 3 Optional name value pairs omconfig storage globalinfo action enablests action disablests action globalrescan action setprotectionpolicies type ghs or dhs omconfig Global Enable Smart Thermal Shutdown By default the operating system and server shut down when the PV220S and PV221S enclosures reach a critical temperature of 0 or 50 degree Celsius However if you have implemented connector redundancy on the PV220S and PV221S enclosures you can specify that only the enclosure and not the operating system and server are shut down when the enclosure reaches a critical temperature of 0 or 50 degree Celsius Specifying that only the enclosure is shut down during excessive temp
105. alue pair 1 name value pair 2 Description config privilegelevel administrator Sets the maximum administrator operator privilege level that is accepted on a serial user over LAN channel to Administrator operator Sets the maximum privilege level that is accepted on a serial over LAN channel to Operator user Sets the maximum privilege level that is accepted on a serial over LAN channel to User config Takes the default configuration settings settodefault config deletecontrol outputdel outputdel BMC outputs a lt Delete gt terminalmode outputbkspspbksp character when lt Backspace gt or handshakingcontrol enabled disabled inputlinesequence cr null lineediting enabled disabled lt Delete gt is received outputbkspspbksp BMC outputs a lt Backspace gt lt Space gt lt Backspace gt character when lt Backspace gt or lt Delete gt is received enabled Directs the BMC to output a character sequence that indicates when its input buffer is ready to accept another command disabled Does not direct the BMC to output a character sequence that indicates when its input buffer is ready to accept another command cr The console uses lt CR gt as a new line sequence null The console uses lt NULL gt as a new line sequence enabled Enables line editing as a line is typed disabled Disables line editing as a line is typed omconfig Managing Components Using the Instrumentation Service
106. and to rescan a controller connector This command rescans all connectors on the controller and is therefore similar to performing a controller rescan K NOTE This command is not supported on SAS controllers Complete Syntax omconfig storage connector action rescan controller id connector id where id is the controller ID and the connector ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage connector controller ID to display the IDs for the connectors attached to the controller 286 omconfig storage Commands Example Syntax To rescan connector 2 on controller 1 type omconfig storage connector action rescan controller 1 connector 2 omconfig Cachecade Commands The following sections provide the omconfig command syntax required to execute cachecade tasks Table 8 15 omconfig Cachecade Commands Required Command Levels 1 2 3 Optional name value pairs omconfig storage cachecade action blink controller id cachecade id action unblink controller id cachecade id action deletecachecade controller id cachecade id force yes action resize controller id cachecade id pdisk lt PDISKID gt action rename controller id cachecade id name lt string gt omconfig Blink Cachecade Use the following omconfig command syntax to blink the physical disks included in a cachecade Complete Syntax omconfig stor
107. assis removableflashmedia Or omreport mainsystem removableflashmedia Server Administrator displays a summary of the system s removable flash media information K NOTE If the vFlash or SD card size is less than 1 GB the size is displayed in MB Depending on the configuration of the system you may notice the following output Removable Flash Media Information Health Critical Internal Dual SD Module Redundancy Critical Attribute Redundancy Value Lost Internal SD Modules Status Status OK Connector Name System Board SD Status 1 State Present Storage Size 512 MB omreport Viewing System Status Using the Instrumentation Service 49 Status OK Connector Name System Board SD Status 2 State Present Storage Size 512 MB VFlash Media Details Connector Name System Board SD Status 1 Type vFlash SD Card State Present Available Size 472 MB Storage Size 512 MB omreport chassis fans or omreport mainsystem fans Use the omreport chassis fans or omreport mainsystem fans command to view the fan probe status and settings Type omreport chassis fans index n or omreport mainsystem fans index n The index parameter is optional If you do not specify the index Server Administrator displays a summary of status readings and thresholds set for any fan probes that are present on the system If you specify the index Server Administrator displays a summary for a specific fan p
108. ation protocol systemsoftware System software if the source of the IP address of the BMC LAN interface is from the system software NOTE All commands are not supported on the system ipaddressv6 lt IPv6 Validates the IPv6 address for address gt prefixlength configuration length gatewayv6 lt value gt Validates the IPv6 gateway ipsourcev6 static auto static IPv6 address source is set to static auto IPv6 address source is set to auto altdnsserverv6 Validates the address of the alternate DNS server for configuration dnssourcev6 static auto static DNS source is set to static auto DNS source is set to auto vlanenable true false true Enables the virtual LAN identification false Disables the virtual LAN identification vlanid number number Virtual LAN identification in the range of 1 to 4094 vlanpriority number number Priority of virtual LAN identification in the range of 0 to 7 140 l omconfig Managing Components Using the Instrumentation Service Table 4 12 Parameters of omconfig chassis remoteaccess or omconfig mainsystem remoteaccess continued name value pair 1 name value pair 2 config Description config nic continued privilegelevel user encryptkey text confirmencryptkey text prefdnsserverv6 lt value gt omconfig Managing Components Using the Instrumentation Service administrator operator administrator Sets the maximum privilege le
109. attached to the controller In some circumstances you may receive a warning message if this command deletes the system or boot partition You can override this warning by using the force yes parameter In this case the syntax is as follows omconfig storage vdisk action fastinit controller id vdisk id force yes Example Syntax To fast initialize virtual disk 4 on controller 1 type omconfig storage vdisk action fastinit controller 1 vdisk 4 omconfig Slow Initialize Virtualize Disk Use the following omconfig command syntax to slow initialize a virtual disk VAN CAUTION You may receive a warning message if you attempt to delete the system or boot partition However this warning message is not generated always Ensure that you do not delete the system or boot partition or other vital data when using this command omconfig storage Commands 237 Complete Syntax omconfig storage vdisk action slowinit controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller Ds and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller In some circumstances you may receive a warning message if this command deletes the system or boot partition You can override this warning by using the force yes parameter In this case the syntax is as follows
110. bb attribute usbb setting enabled enabledwithbios disabled enabled Enables the USB port s during system boot without BIOS support enabledwithbios Enables the USB port s during system boot with BIOS support disabled Disables the USB port s during system boot NOTE Depending on the system s hardware you can configure either usb or usbb attribute cstates setting enabled disabled enabled Enables the processor from going to a deep sleep state when the system is not utilized disabled Disables the processor from going into a deep sleep state when the system is not utilized 114 omconfig Managing Components Using the Instrumentation Service Table 4 4 displays the BIOS setup attributes supported on PowerEdge yx2x systems On PowerEdge yx2x systems the attributes are grouped Based on the hardware configuration the possible attributes may vary in a specific group The omconfig chassis biossetup command does not display the read only attributes K NOTE If you have configured the setup password then always set the same when you configure any BIOS settings Table 4 4 BIOS Setup Settings on PowerEdge yx2x Systems Group name value pair 1 attribute name value pair 2 setting BIOS Boot Settings attribute BootSeq attribute HddSeq sequence aliasnamel aliasname2 aliasnameN sequence aliasnamel aliasname2 aliasnameN Boot Settings attri
111. bootorder NOTE On Linux systems user or user groups upgraded to administrator or administrator groups cannot configure this BIOS setup setting attribute hddorder sequence aliasnamel aliasname2 aliasnameN Configures the BIOS setup hard disk sequence according to the set aliasnames Changes takes effect after rebooting the system To view the set alias names run the command omreport chassis biossetup attribute bootorder NOTE On Linux systems user or user groups upgraded to administrator or administrator groups cannot configure this BIOS setup setting attribute cstates setting enabled disabled enabled Enables the processor to go into a deep sleep state when the system is not utilized disabled Disables the processor to go into a deep sleep state when the system is not utilized 102 omconfig Managing Components Using the Instrumentation Service Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems continued name value pair 1 attribute name value pair 2 setting Description attribute conredirect setting enabled disabled enabled Redirects the BIOS screen output over serial port 1 Keyboard and text output are redirected over serial port 2 disabled Turns off the BIOS console redirection attribute crab setting enabled disabled enabled Enables BIOS console redirection after system reboot disabled Disables BIOS c
112. bute BootMode attribute BootSeqRetry setting Bios Uefi setting Enabled Disabled Embedded Server Management attribute FrontLcd attribute UserLcdStr setting None UserDefined ModelNum Advanced setting lt string gt Integrated Devices omconfig Managing Components Using the Instrumentation Service attribute EmbVideo attribute IntegratedNetwork1 attribute IntegratedNetwork2 attribute IntegratedRaid attribute IntegratedSas attribute InternalSdCard attribute InternalSdCard Redundancy attribute InternalUsb attribute InternalUsbl setting Enabled Disabled setting Enabled DisabledOs setting Enabled DisabledOs setting Enabled Disabled setting Enabled Disabled setting On Off setting Mirror Disabled setting On Off setting On Off 115 Table 4 4 BIOS Setup Settings on PowerEdge yx2x Systems continued Group name value pair 1 attribute name value pair 2 setting Integrated Devices attribute InternalUsb2 continued attribute loatEngine attribute OsWatchdogTimer attribute SriovGlobalEnable attribute UsbPorts setting 0n Off setting Enabled Disabled setting Enabled Disabled setting Enabled Disabled setting AllOn OnlyBackPortsOn AllOff Memory Settings attribute MemOpMode attribute MemOpVoltage attribute MemTest attribute NodelInterleave attribute SerialDbgOut attribute SysMemSize attribute Sys
113. ce lt PDISKID gt where id is the subsystem ID and lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To add the specified PCle SSD device to the cachepool type omconfig storage pciessd action addtocachepool subsystem 2 pciedevice 0 2 0 force yes omconfig Remove PCle SSD Device From Cachepool Use the following omconfig command syntax to remove the specified PCle SSD device from the cache pool Complete Syntax omconfig storage pciessd action removefromcachepool subsystem id pciedevice lt PDISKID gt where id is the subsystem ID and lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To remove the specified PCIe SSD device from the cachepool type omconfig storage pciessd action removefromcachepool subsystem 2 pciedevice 0 2 0 force yes omconfig storage Commands 291 omconfig Reactivate PCle SSD Device Use the following omconfig command syntax to reactivate the specified PCle SSD device that was part of the cache pool Complete Syntax omconfig storage p
114. ch a correctable memory event is detected enables the spare bank and copies all the data from the original bank to the spare bank Spare bank requires at least three banks of identical memory the operating system does not recognize the spare bank Mirror mode switches to a redundant copy of memory when an uncorrectable memory event is detected After switching to the mirrored memory the system does not switch back to the original system memory until the next reboot The operating system does not recognize half of the installed system memory in this mode RAID mode provides an extra level of memory checking and error recovery at the expense of some memory capacity The DDDC mode enables double device data correction This ensures data availability after hard failure of x4 DRAM K NOTE This command is applicable only on systems prior to PowerEdge yx2x systems To configure the attribute on PowerEdge yx2x systems refer Table 4 4 130 omconfig Managing Components Using the Instrumentation Service Table 4 9 lists the valid parameters for the command Table 4 9 Parameters of omconfig chassis memorymode or omconfig mainsystem memorymode name value pair 1 Description index lt n gt Number of the chassis where the memory module resides the default is chassis 0 the main system chassis redundancy spare mirror disabled raid5 dddc spare Disables the memory module that has a correctable memory event
115. ch as I O address IRQ level connector type and maximum speed Displays properties of the system s processors including speed manufacturer and processor family Displays power inventory details such as system idle power system maximum potential power and power budget information Displays properties of power consumption Displays the properties of power supplies omreport Viewing System Status Using the Instrumentation Service 35 Table 3 2 Command Level 1 Level 2 and Level 3 for omreport continued Command Command Level 2 Command Level 1 Level 3 User Privilege Required Use remoteaccess slots temps volts removableflash media storage system or servermodule alertaction U PA U P A U P A U P A Rac gt Displays general information on remote access Displays the properties of the system s expansion slots and other slot types Displays the status and thresholds for the system temperature sensors Displays the status and thresholds for the system voltage sensors Displays the system s virtual flash vFlash and secure digital SD card details See Using the Storage Management Service on page 197 Displays a high level summary of system components Displays the warning and failure threshold values as well as actions configured when an essential component detects a warning or failure state 36 omreport Viewi
116. checade 4 pdisk 0 2 0 0 2 1 0 2 2 0 2 3 omconfig storage Commands 289 omconfig Rename Cachecade Use the following omconfig command syntax to rename a cachecade Complete Syntax omconfig storage cachecade action rename controller id cachecade id name lt string gt where id is the controller ID and cachecade ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage cachecade controller ID to display the IDs for the cachecades of the controller Example Syntax To rename cachecade 4 on controller to cct4 type omconfig storage cachecade action rename controller 1 cachecade 4 name cc4 omconfig PCle SSD Commands The following sections provide the omconfig command syntax required to execute PCle SSD tasks Table 8 16 omconfig PCle SSD Commands Required Command Levels 1 2 3 Optional name value pairs omconfig storage pciessd action addtocachepool subsystem id pciedevice lt PDISKID gt force yes action removefromcachepool subsystem id peiedevice lt PDISKID gt force yes action reactivate subsystem id pciedevice lt PDISKID gt force yes omconfig Add PCle SSD Device to Cachepool Use the following omconfig command syntax to add the specified PCIe SSD device to the cache pool 290 omconfig storage Commands Complete Syntax omconfig storage pciessd action addtocachepool subsystem id pciedevi
117. ciessd action reactivate subsystem id pciedevice lt PDISKID gt where id is the subsystem ID and lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To reactivate the specified PCIe SSD device type omconfig storage pciessd action reactivate subsystem 2 pciedevice 0 2 0 force yes omconfig Fluid Cache Commands The following sections provide the omconfig command syntax required to execute fluid cache tasks Table 8 17 omconfig Fluid Cache Commands Required Command Levels 1 2 3 Optional name value pairs omconfig storage fluidcache action applylicense licensefile lt filename gt action connect omconfig Applying or Updating License to the Fluid Cache Use the following omconfig command syntax to apply or upgrade the fluid cache license 292 omconfig storage Commands Complete Syntax omconfig storage fluidcache action applylicense licensefile lt filename with absolute path gt Example Syntax omconfig storage fluidcache action applylicense licensefile root key licensefile xml omconfig Conecting to the Fluid Cache Use the following omconfig command syntax to connect to the fluid cache system and update the cache configuration details of the storage subsystem C
118. config system alertaction or omconfig servermodule alertaction command to determine how Server Administrator responds when a component has a warning or failure event NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator Defining Alert Actions An alert action is an action that you specify for the system to take when specified conditions are met Alert actions determine in advance what actions to take for warning or failure events on intrusion fans temperatures voltages power supplies memory and redundancy For example if a fan probe on the system reads a fan RPM of 300 and your minimum warning threshold value for that fan probe is 600 RPM then the system generates a fan probe warning Alert action settings determine how users are notified of this event You can also configure alert actions for temperature voltage and probe readings that are within the warning or failure range Syntax for Setting Alert Actions Setting an alert action requires two name value pairs The first name value pair is the event type The second name value pair is the action to take for this event For example in the command omconfig system alertaction event powersupply broadcast true Or omconfig servermodule alertaction event powersupply broadcast true 158 l omconfig Managing Components Using the Instrumentation Service
119. covery action is initiated type omconfig system recovery timer 120 or omconfig servermodule recovery timer 120 172 omconfig Managing Components Using the Instrumentation Service omconfig system shutdown or omconfig servermodule shutdown Use the omconfig system shutdown or omconfig servermodule shutdown command to determine the way in which the system shuts down During system shutdown the default is to shut down the operating system before powering off the system Shutting down the operating system first closes down the file system before powering the system down If you do not want to shut down the operating system first use the osfirst false parameter Table 4 31 lists the valid parameters for the command K NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator Table 4 31 Shutdown Parameters name value pair Description action reboot Shuts down the operating system and initiates system startup performing BIOS checks and reloading the operating system action poweroff Turns off the electrical power to the system action powercycle Turns off the electrical power to the system pauses turns the power on and reboots the system Power cycling is useful when you want to re initialize system components such as hard drives osfirst true false true Closes the file system and exits the o
120. ctor Displays a list of the omconfig storage connector parameters for configuring connectors cachecade Displays a list of the omconfig storage cachecade parameters for configuring cachecades pciessed Displays PCIe SSD configuration commands fluidcache Displays the fluid cache properties and the associated fluid cache disks fluidcachepool Displays the fluid cache pool properties partition Displays the partition details of the specified controller and virtual disk fluidcachedisk Displays the fluid cache disk properties omconfig Physical Disk Commands The following sections provide the omconfig command syntax required to execute physical disk tasks Table 8 2 omconfig Physical Disk Commands Required Command Levels Optional name value pairs 1 2 3 omconfig storage pdisk action blink controller id pdisk lt PDISKID gt action unblink controller id pdisk lt PDISKID gt action remove controller id pdisk lt PDISKID gt action instantsecureerase controller id pdisk lt PDISKID gt action initialize controller id pdisk lt PDISKID gt action offline controller id pdisk lt PDISKID gt action online controller id pdisk lt PDISKID gt action assignglobalhotspare controller id pdisk lt PDISKID gt assign lt yes no gt action rebuild controller id pdisk lt PDISKID gt action cancelrebuild controller id pdisk lt PDISKID gt 218 omconfig storage Commands Table 8 2 omconfig Physica
121. d 12 NOTE For the supported operating systems list see the De Systems Software Support Matrix at dell com support manuals Select Choose from a list of all Dell products option and click Continue Click Software Monitors Electronics amp Peripherals Software Enterprise System Management NOTE CLI commands are not supported on systems with VMware ESXi operating system Accessing the Windows Command Prompt to Run CLI Commands If you are running the Microsoft Windows operating system use the 32 bit command prompt to run a Server Administrator CLI command Access the 32 bit command prompt using one of the following methods K Click Start Programs Accessories Command Prompt Click Start Run and type cmd exe NOTE Do not type command in the Run dialog box to launch a command line window this activates the MS DOS emulator command com which has environment variable limitations that can cause subtle problems with CLI Primary CLI Commands The commands that carry out the functions of Server Administrator are omconfig omhelp omreport Introduction 19 The omconfig command writes values that you assign to an object s properties You can specify values for warning thresholds on components or prescribe action that the system must perform when a certain warning or failure event occurs You can also use the omconfig command to assign specific values to the system s asset information parameters such as the purchas
122. d is the controller number For example controller 0 controller id connector id where id is the connector number For example connector 0 NOTE This command works only when the controller ID is specified Displays the connectors on the specified controller Displays the specified connector NOTE When the connectors are connected to the enclosure in redundant path mode the Name of the connector is displayed as Logical Connector omreport storage Commands 213 omreport Cachecade Status Table 7 14 describes the syntax for the omreport cachecade commands Table 7 14 omreport Cachecade Commands Required Command Optional name value pairs Use Levels 1 2 3 omreport storage Displays property information cachecade for all cachecades on all controllers controller id Displays all cachecades on the where id is the controller specified controller number For example controller 0 controller id cachecade id Displays the specified yhere id tothe contol cachecade on the controller number and the cachecade number For example controller 0 cachecade 1 omreport PCle SSD Status Table 7 14 describes the syntax for the omreport pciessd command Table 7 15 omreport PCle SSD Command Required Command Optional name value pairs Use Levels 1 2 3 omreport storage Displays the properties of the pciessd PCle SSD subsystem subsystem id Displays the properties of the specifi
123. d on random System is turned on with random delay immediate System returns to previous state immediately timedelay lt value gt System is turned on based on user specified time delay attribute bezel setting enabled disabled enabled Enables the bezel removal intrusion check during system boot disabled Disables the bezel removal intrusion check during system boot attribute setting diskettefirst Instructs the BIOS which device is used bootsequence hdonly devicelist to boot the system and the order in cdromfirst which the boot routine checks each opticaldrive device NOTE On Linux systems user or user groups upgraded to administrator or administrator groups cannot configure this BIOS setup setting attribute setting uefi bios uefi Enables the system to boot to bootmode operating systems that support Unified Extensible Firmware Interface UEFI bios Enables the system to boot to operating systems that do not support UEFI omconfig Managing Components Using the Instrumentation Service 101 Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems continued name value pair 1 attribute name value pair 2 setting Description attribute bootorder sequence aliasnamel aliasname2 aliasnameN Configures the boot sequence according to the set aliasnames To view the set alias names run the command omreport chassis biossetup attribute
124. e startdate Date the maintenance lt startdate gt begins restrictions Activities not covered lt string gt by the maintenance contract Example Command for Adding Maintenance Information To provide a value for a maintenance parameter type a command of the form omconfig system assetinfo info maintenance lt name value pair 2 gt or omconfig system assetinfo info maintenance lt name value pair 2 gt For example type omconfig system assetinfo info maintenance startdate 012504 Or omconfig servermodule assetinfo info maintenance startdate 012504 The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to name value pair 1 For an example see Example Commands for Adding Acquisition Information on page 179 omconfig system or servermodule assetinfo Editing Cost of Ownership Values 185 Adding Outsource Information Outsourcing is the practice of contracting with another business to maintain the system in good working order Table 5 7 lists the valid parameters for adding outsource information Table 5 7 Parameters of omconfig system assetinfo info outsource or omconfig servermodule assetinfo info outsource Command Command Level Command Name Name Value Pair2 Description Level 1 2 Level3 Value Pair 1 omconfig
125. e deprecated onpxeboth Enables PXE on both the NICs onpxenone PXE is not enabled on either of the NICs onpxenicl Enables PXE on NIC 1 onpxenic2 Enables PXE on NIC 2 omconfig Managing Components Using the Instrumentation Service 105 Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems continued name value pair1 name value pair 2 Description attribute setting attribute setting enabled enabled Enables the embedded embhypvisor disabled hypervisor disabled Disables the embedded hypervisor attribute setting enabled enabled Enables the embedded video embvideoctrl disabled controller as the primary video device disabled Disables the embedded video controller as the primary video device attribute setting off auto off Sets the embedded SATA port value esataport to off auto Sets the embedded SATA port value to auto attribute setting com1 com2 com Maps the external serial extserial rad connector to COM 1 com2 Maps the external serial connector to COM 2 rad Maps the external serial connector to the remote access device attribute fbr setting 9600 19200 57600 115200 9600 Sets the console redirection failsafe baud rate to 9600 bits per second 19200 Sets the console redirection failsafe baud rate to 19200 bits per second 57600 Sets the console redirection failsafe baud rate to 57600 bits per second 115200 Sets the c
126. e 5 8 lists the valid parameters for adding owner information Table 5 8 Parameters of omconfig system assetinfo info owner or omconfig servermodule assetinfo info owner Command Command Command Name Value Name Value Description Level 1 Level 2 Level3 Pair 1 Pair 2 omconfig system or servermodule assetinfo info owner insuranceco Name of the insurance company that insures the lt company gt system ownername Business entity that owns the system lt business gt type owned Whether the user of the leased system owns leases or rented rents the system Example Command for Adding Owner Information To provide a value for an owner parameter type a command of the form omconfig system assetinfo info owner lt name value pair 2 gt or omconfig servermodule assetinfo info owner lt name value pair 2 gt For example type omconfig system assetinfo info owner type rented Or omconfig servermodule assetinfo info owner type rented The following message is displayed Asset information set successfully 188 omconfig system or servermodule assetinfo Editing Cost of Ownership Values You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to name value pair 1 For an example see Example Commands for Adding Acquisition Information on page 179 Adding Service Contract Informat
127. e IDs for the physical disks attached to the controller Example Syntax To assign the physical disk 3 on connector 0 of controller 1 as a global hot spare e For SCSI SATA and ATA controllers omconfig storage pdisk action assignglobalhotspare controller 1 pdisk 0 3 assign yes 224 omconfig storage Commands e For SAS controllers omconfig storage pdisk action assignglobalhotspare controller 1 pdisk 0 2 3 assign yes K NOTE On a SAS controller the physical disk resides in enclosure 2 omconfig Rebuild Physical Disk Use the following omconfig command syntax to rebuild a failed physical disk Rebuilding a disk may take several hours If you need to cancel the rebuild use the Cancel Rebuild task See the Dell OpenManage Online Help for more information about Rebuild Physical Disk Complete Syntax omconfig storage pdisk action rebuild controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To rebuild the physical disk 3 on connector 0 of controller 1 e For SCSI SATA and ATA controllers omconfig storage pdisk action rebuild controller 1 pdisk 0 3 e For SAS controllers omconfig storage pdisk action rebuild controlle
128. e action blink controller 1 enclosure 2 3 omconfig Battery Commands The following sections provide the omconfig command syntax required to execute battery tasks Table 8 12 omconfig Battery Commands Required Command Levels 1 2 3 Optional name value pairs omconfig storage battery action startlearn controller id battery id action delaylearn controller id battery id days d hours h omconfig Start Battery Learn Cycle Use the following omconfig command to start the battery learn cycle Complete Syntax omconfig storage battery action startlearn controller id battery id where id is the controller ID and battery ID as reported by the omreport command To obtain this value type omreport storage controller to display the controller IDs and then type omreport storage battery controller ID to display the ID for the controller battery omconfig storage Commands 281 Example Syntax To start the learn cycle on controller 1 type omconfig storage battery action startlearn controller 1 battery 0 omconfig Delay Battery Learn Cycle Use the following omconfig command to delay the battery learn cycle for a specified period of time You can delay the battery learn cycle for a maximum of seven days or 168 hours Complete Syntax omconfig storage battery action delaylearn controller id battery id days d hours h where id is the controller ID and battery ID as reported by the omreport command To obtain this v
129. e price of the system the system s asset tag or the system s location The omhelp command displays short text help for CLI commands The shorthand equivalent of omhelp is the command for which you want help followed by For example to display help for the omreport command type one of the following commands omhelp omreport omreport The omreport command displays reports of the management information of the system K NOTE For an overall summary of the CLI commands type omhe1p Table 1 1 lists the primary CLI commands used by Server Administrator This guide contains a section for each primary command Table 1 1 CLI Commands and Sections in This Guide Primary CLI Section Title Related Sections Command omconfig omconfig Managing Components omconfig system or Using the Instrumentation Service servermodule assetinfo Editing on page 91 Cost of Ownership Values on page 177 omhelp Using the omhelp Command on page 27 omreport omreport Viewing System Status Using the Instrumentation Service on page 31 K NOTE The omupdate commands are no longer supported in Server Administrator and are replaced by Dell Update Package or the Server Update Utility commands To update the different components download the Dell Update Package and run the lt package name gt s command For more information on the 20 Introduction corresponding CLI syntax see the De Update Packages for Operating Systems Us
130. e recovery command to see whether there is an action configured for a hung operating system Also view the number of seconds that must elapse before an operating system is considered hung omreport system shutdown or omreport servermodule shutdown Use the omreport system shutdown or omreport servermodule shutdown command to view any pending shutdown actions for the system If properties for shutdown are configured executing this command displays these properties K NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator omreport system summary or omreport servermodule summary Use the omreport system summary or omreport servermodule summary command to view a comprehensive summary of software and hardware components currently installed on the system Type omreport system summary or omreport servermodule summary K NOTE If the vFlash or SD card size is less than 1 GB the size is displayed in MB K NOTE If iDRAC is installed Server Administrator displays the LCC version If BMC is installed Server Administrator displays the USC version 80 omreport Viewing System Status Using the Instrumentation Service The output that is displayed in the CLI window depends on the systems management software operating system and hardware components and options installed on the system The following partial command resul
131. e severity level at which a thermal event triggers a system shutdown Starts or stops the Web server Configures the behavior of specific system components controlled by the BIOS Configures fan probe warning thresholds by default or by value NOTE You cannot change threshold values on embedded server management ESM3 and Dell PowerEdge x8xx systems Configures the Power button Non Masking Interrupt NMI button encryption access and LCD display of the system Allows you to set an initial value or to edit the value of the asset tag or chassis name omconfig Managing Components Using the Instrumentation Service 95 Table 4 2 omconfig Command Level 1 Level 2 and Level 3 continued Command Command Command Level3 User Use Level 1 Level 2 Privilege Required leds PA Specifies when to flash a chassis fault LED or chassis identification LED and allows you to clear the LED for the system s hard drive memorymode lt A Enables or disables the spare bank mirroring raid and Double Device Data Correction DDDC memory modes and also specify which mode to use pwrmanagement P A Allows you to choose between maximum performance with minimal power and optimized performance of the system pwrmonitoring PA Configures power consumption information and thresholds remoteaccess A Configures remote access information temps PA Sets warning threshold values to default or a specific value
132. e systems Example Set Alert Action Commands The following examples are valid example commands For each successful command issued the following message is displayed Alert action s configured successfully For Current Probe Actions To disable system console alert if a current probe detects a warning event type omconfig system alertaction event currentwarn alert false Or omconfig servermodule alertaction event currentwarn alert false To enable broadcast messages if a current probe detects a failure event type omconfig system alertaction event currentfail broadcast true Or omconfig servermodule alertaction event currentfail broadcast true e For Fan Probe Actions To generate alerts when a fan probe detects a failure value type omconfig system alertaction event fanfail alert true Or omconfig servermodule alertaction event fanfail alert true 162 omconfig Managing Components Using the Instrumentation Service e For Chassis Intrusion Actions To clear all alert actions for chassis intrusion type omconfig system alertaction event intrusion clearall true Or omconfig servermodule alertaction event intrusion clearall true Commands for Clearing Logs K NOTE For more information about alert messages see the De OpenManage Server Administrator Messages Reference Guide at dell com support manuals You can use the omconfig system or omconfig servermodule command to clear three logs the
133. eam index n NOTE This command is applicable only if Team interface is configured in the system Team interface is configured using NIC vendor tools such as Broadcom The index parameter is optional If you do not specify the index Server Administrator displays details of all the Team interfaces on the system and the values for the following fields Index NIC card number Interface Name Vendor Description and Redundancy Status If you specify the index Server Administrator displays the Team interface details for the specific NIC and the values for the following fields Team Interface Interface IPv4 Addresses IPv6 Addresses Team Interface Receive Statistics Team Interface Transmit Statistics Interface Receive Statistics and Interface Transmit Statistics omreport chassis ports or omreport mainsystem ports Use the omreport chassis ports or omreport mainsystem ports command to view properties of the system s parallel and serial ports Server Administrator displays values for the following fields Port Type External Name Base I O Address IRO Level Connector Type and Maximum Speed omreport Viewing System Status Using the Instrumentation Service 57 Port Type is the detailed type of each system port from the more general serial parallel and USB ports to the names of ports by device type connected to it for example pointing device or keyboard External Name is the name of the port such as serial or parallel US
134. ed PCle subsystem omreport Fluid Cache Status Table 7 14 describes the syntax for the omreport fluidcache command 214 omreport storage Commands Table 7 16 omreport Fluid Cache Command Required Command Levels 1 2 3 Use omreport storage fluidcache Displays fluid cache properties and the associated fluid cache disks omreport Fluid Cache Pool Status Table 7 14 describes the syntax for the omreport fluidcachepool command Table 7 17 omreport Fluid Cache Pool Command Required Command Levels 1 2 3 Use omreport storage fluidcachepool Displays the properties of the fluid cache pool omreport storage Commands 215 omreport Partition Status Table 7 14 describes the syntax for the omreport partition commands Table 7 18 omreport Partition Commands Required Command Optional name value pairs Use Levels 1 2 3 omreport storage Displays the partition details partition of the specified virtual disk controller id vdisk id Displays all the partitions in the specified virtual disk on the controller where id is the controller number and the virtual disk number For example controller 0 vdisk 1 omreport Fluid Cache Disk Status Table 7 14 describes the syntax for the omreport fluidcachedisk command Table 7 19 omreport Fluid Cache Disk Command Required Command Levels 1 2 3 Use omreport storage fluidcachedisk Displays the properties of the fluid cache dis
135. els to 128 bit or higher attribute seturl host lt string gt port Enables you to configure the URL lt value gt launch point in the Server Administrator Web server environment attribute algorithm MD5 MDS Sets the key signing algorithm signalgorithm SHA1 SHA256 to MD5 SHAS 12 SHA1 Sets the key signing algorithm to SHAI SHA256 Sets the key signing algorithm to SHA256 SHAS 12 Sets the key signing algorithm to SHA512 For example to set the URL launch point use the following command omconfig preferences webserver attribute seturl host lt name ip fqdn gt port lt number gt The host input must contain a valid IPv4 or IPv6 address or a valid hostname To set the signing algorithm value use the following command omconfig preferences webserver attribute signalgorithm algorithm lt MD5 SHA1 SHA256 SHA512 gt For more information on configuring Web server preferences see the Dell OpenManage IT Assistant User s Guide at dell com support manuals omconfig Managing Components Using the Instrumentation Service 157 omconfig system or omconfig servermodule Use the omconfig system or omconfig servermodule commands to clear logs determine how various shutdown actions occur set initial values or edit values for cost of ownership information and determine how to respond to a hung operating system omconfig system alertaction or omconfig servermodule alertaction You can use the om
136. em has hung or is not responding omconfig system events or omconfig servermodule events Use the omconfig system events or omconfig servermodule events command to enable and disable SNMP traps for the components on your system K NOTE Not all event types are present on the system There are four parameters in the name value pair component of the omconfig system events command 168 Source Type Severity Index omconfig Managing Components Using the Instrumentation Service Source At present source snmpt raps is a required name value pair because SNMP is currently the only supported source of event notification for the system s components omconfig system events source snmptraps or omconfig servermodule events source snmptraps Type Type refers to the name of the component s involved in the event Table 4 27 lists the valid parameters for system event types Table 4 27 System Event Type Parameters name value pair Configures Events for type accords AC power cords type battery Battery type all All device types type fanenclosures Fan enclosures type fans Fans type intrusion Chassis intrusion type log Logs type memory Memory type powersupplies Power supplies type redundancy Redundancy type systempower System power type temps Temperatures type volts Voltages type systempeakpower System peak power t
137. enclosureID targetID is the connector number enclosure number and slot number For example pdisk 0 1 2 e For SAS controllers pdisk connector targetID where connector D targetID is the connector number and the slot number For example pdisk 0 2 Storage Management supplies default values for any of the other parameters that you do not specify For creating an encrypted virtual disk specify secureflag yes You can create encrypted virtual disks only with SED drives Complete Syntax omconfig storage controller action createvdisk controller id raid lt c ro r1 ric r5 r6 r10 r50 r60 gt size lt number max min gt pdisk lt PDISKID gt stripesize lt 2kb 4kb 8kb 16kb 32kb 64kb 128kb gt cachepolicy lt d c gt diskcachepolicy lt disabled enabled gt readpolicy lt ra nra ara re nre gt writepolicy lt wb wt wc nwe fwb gt name lt string gt spanlength lt n gt secureflag yes K NOTE If you are configuring RAID for SAS controllers with firmware version 6 1 and later spanlength is an optional parameter default 2 Spanlength is an even number and is lesser than or equal to half the number of physical disks specified in size Parameter Specification for Create and Reconfigure Virtual Disk The following sections indicate how to specify the omconfig storage controller action createvdisk parameters controller id Parameter Required raid lt c rO rl rlc r5 r6 r10
138. eport chassis nics or omreport mainsystem nics Use the omreport chassis nics or omreport mainsystem nics command to view NIC and Team interface details On XenServer the command displays all the installed NICs regardless of driver installation K NOTE The order in which devices are detected is not guaranteed to match the physical port ordering of the device To view NIC properties type 56 omreport chassis nics index n or omreport mainsystem nics index n l omreport Viewing System Status Using the Instrumentation Service The index parameter is optional If you do not specify the index Server Administrator displays properties of all NICs on the system and the values for the following fields Index NIC card number Interface Name Vendor Description Connection Status and Slot If you specify the index Server Administrator displays properties for a specific NIC and the values for the following fields Physical Interface Interface name IPv4 Addresses IPv6 Addresses Physical Interface Receive Statistics Physical Interface Transmit Statistics Interface Receive Statistics and Interface Transmit Statistics K NOTE The Fibre Channel over Ethernet FCoE and iSCSI over Ethernet iSoE features of Converged Network Adapter CNA cards are not supported on VMware ESX and VMware ESXi systems To view Team interface properties type omreport chassis nics config team index n or omreport mainsystem nics config t
139. er except that warning events always precede failure events for a component omconfig Managing Components Using the Instrumentation Service 159 160 Table 4 23 Events for Which You Can Set Alert Actions Event Name Description event batterywarn Sets actions when a battery probe detects a warning value event batteryfail Sets actions when a battery probe detects a failure value event fanwarn Sets actions when a fan probe detects a warning value event fanfail Sets actions when a fan probe detects a failure value event hardwarelogwarn Sets actions when a hardware log detects a warning value event hardwarelogfull Sets actions when a hardware log is full event intrusion Sets actions when a chassis intrusion event is detected event memprefail Sets actions when a memory probe detects a prefailure value event memfail Sets actions when a memory probe detects a failure value event systempeakpower Sets actions when a power consumption probe detects peak power value event systempowerwarn Sets actions when a power consumption probe detects a warning value event systempowerfail Sets actions when a power consumption probe detects a failure value event powersupply Sets actions when a power supply probe detects a failure value event powersupplywarn Sets actions when a power supply probe detects a warning value e
140. er ID The lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax In this example you want to cancel the clear of physical disk 3 on connector 0 of controller 1 On a SAS controller the physical disk resides in enclosure 2 To cancel the clear of the physical disk described in this example e For SCSI SATA and ATA controllers omconfig storage pdisk action cancelclear controller 1 pdisk 0 2 3 omconfig Enable Device Write Cache Use the following omconfig command to enable write cache on a physical disk for the PCIe SSD controller Complete Syntax omconfig storage pdisk action nabledevicewritecache controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller 228 omconfig storage Commands Example Syntax To enable write cache on physical disk 3 on connector 0 of controller 1 e For SAS controllers omconfig storage pdisk action nabledevicewritecache controller 1 pdisk 0 2 3 K NOTE On a SAS controller the physical disk
141. eratures is known as Smart Thermal Shutdown See the Dell OpenManage Online Help for more information about Smart Thermal Shutdown Use the following omconfig command syntax to enable smart thermal shutdown Complete Syntax omconfig storage globalinfo action enablests omconfig storage Commands 283 Example Syntax The omconfig command syntax for enabling thermal shutdown does not require that you specify a controller or enclosure ID To enable thermal shutdown type the following omconfig storage globalinfo action enablests K NOTE You can use the omreport storage globalinfo command to determine whether smart thermal shutdown is currently enabled or disabled The status of smart thermal shutdown is also displayed by the Server Administrator graphical user interface GUI To locate this status select the Storage object and the Information Configuration tab omconfig Global Disable Smart Thermal Shutdown If you have previously enabled smart thermal shutdown using the omconfig command you can disable smart thermal shutdown and return the system to its default setting When smart thermal shutdown is disabled the operating system and the server shuts down when the PV220S and PV221S enclosures reach a critical temperature of 0 or 50 degree Celsius Use the following omconfig command syntax to disable smart thermal shutdown for all controllers Complete Syntax omconfig storage globalinfo action disablests Example Sy
142. ers Guide or the Dell OpenManage Server Update Utility User s Guide at dell com support manuals Additional useful topic about the CLI include Working With CLI Command Results on page 295 CLI Error Checking and Error Messages When you type CLI commands the CLI checks these commands for correct syntax If you type a command and the command is executed successfully a message is displayed stating that the command is successful Success Messages When you run a successful omconfig command data for that component is displayed The following table provides examples of valid omconfig commands and their success messages Table 1 2 Commands and Messages Command Message omconfig chassis temps Temperature probe warning index 0 warnthresh threshold value s set default successfully omconfig chassis biossetup BIOS setup configured attribute numlock successfully Change will setting on take effect after the next reboot omconfig system assetinfo Asset information set info depreciation successfully duration 6 K NOTE Due to limitations some commands do not alter the system settings even though the commands are executed successfully This is an expected behavior Introduction 21 Failure Messages CLI failure messages provide reasons why some commands do not succeed Some common reasons why commands fail include syntax errors and components that are not present Many error messages provide syntax
143. ers of omconfig chassis remoteaccess or omconfig mainsystem remoteaccess continued name value pair 1 name value pair 2 config Description config user continued id number newpw text confirmnewpw text id number serialaccesslevel administrator operator user none id number lanaccesslevel administrator operator user none id number ID in numeric format of the user being configured newpw text New password of the user confirmnewpw text Confirm the new password id number ID in numeric format of the user being configured serialaccesslevel administrator User with an ID has access privileges of an Administrator for the serial port channel serialaccesslevel operator User with an ID has access privileges of an Operator for the serial port channel serialaccesslevel user User with an ID has access privileges of a User for the serial port channel serialaccesslevel none User with an ID does not have access privileges for the serial port channel id number ID number of the user being configured lanaccesslevel administrator User with an ID has access privileges of an Administrator for the LAN channel lanaccesslevel operator User with an ID has access privileges of an Operator for the LAN channel lanaccesslevel user User with an ID has access privileges of a User for the LAN channel lanaccesslevel none User with an ID does not have access privileges for t
144. es the CLI is ideal Using CLI commands administrators can write batch programs or scripts to execute at specific times When these programs execute they can capture reports on components of interest such as fan RPMs during periods of highest system usage compared with the same measurements at times of lowest system usage Command results are routed to a file for later analysis Reports can help administrators gain information that are used to adjust usage patterns to justify purchasing new system resources or to focus on the health of a problem component Introduction 23 Command Syntax Overview Commands vary in complexity The simplest command has only command level 1 The omhelp command is a simple command When you type omhelp a list of the main CLI commands is displayed The next level of complexity includes commands that contain command levels 1 and 2 All of the about commands are examples of command level 2 complexity The omconfig about and omreport about commands display a very brief summary The summary shows version information for the systems management software installed on the system for example Server Administrator 1 x Some commands have command level 1 and command level 2 and one name value pair Consider the following example command that instructs Server Administrator for more details about the environment for Server Administrator omreport about details true Command level 1 is omreport command level 2
145. eshold 151 Index 307 name value pairs omcontig chassis biossetup 101 omcontig chassis bmc 137 nics omreport chassis 56 NMI button 51 0 omconfg cancel initialize virtual disk 238 omconfig 308 97 about 98 99 assign dedicated hot spare 239 assign global hot spare 224 background initialization rate 264 blink physical disk 219 blink virtual disk 235 287 cancel background initialize 239 cancel check consistency 233 cancel rebuild physical disk 226 Change Controller Properties 262 change controller properties 262 change encryption key controller 263 change virtual disk policy 244 chassis 100 check consistency 233 command levels 1 2 and 3 93 Index command parameter table conventions 92 command summary 92 Create Encryption Key Controller 263 create virtual disk 255 delete encryption key controller 264 delete virtual disk 240 288 289 disable controller alarm 253 disable enclosure alarm 275 discard preserved cache controller 262 enable controller alarm 252 enable enclosure alarm 275 format virtual disk 241 getting help 97 global disable smart thermal shutdown 284 global enable smart thermal shutdown 283 global rescan controller 285 initialize virtual disk 222 236 online physical disk 223 pause check consistency 234 prepare to remove physical disk 221 quiet controller alarm 253 rebuild physical disk 225 reconfiguring v
146. etalltempprobes controller 1 enclosure 2 3 minwarn 10 maxwarn 40 omconfig storage Commands 279 omcontfig Reset All Temperature Probe Thresholds Use the following omconfig command syntax to reset the minimum and maximum warning temperature thresholds back to their default value for all temperature probes in the enclosure K NOTE This command is not supported on SCSI RAID controllers Complete Syntax omconfig storage enclosure action resetalltempprobes controller id enclosure lt ENCLOSUREID gt where id is the controller ID The lt ENCLOSUREID gt variable specifies the enclosure Example Syntax To reset the thresholds for all temperature probes in enclosure 3 attached to connector 2 on controller 1 e For SAS controllers omconfig storage enclosure action resetalltempprobes controller 1 enclosure 2 3 omconfig Blink Use the following omconfig command to blink the light emitting diodes LEDs on the enclosure Complete Syntax omconfig storage enclosure action blink controller id enclosure lt ENCLOSUREID gt where id is the controller ID The lt ENCLOSUREID gt variable specifies the enclosure 280 omconfig storage Commands Example Syntax To blink the LEDs for enclosure 3 attached to connector 2 on controller 1 e For SCSI SATA and ATA controllers omconfig storage enclosure action blink controller 1 enclosure 2 e For SAS controllers omconfig storage enclosur
147. evel 2 and Level 3 continued Command Command Command Level 3 Level 1 Level 2 User Privilege Required Use alertaction alertlog assetinfo cmdlog esmlog events pedestinations platformevents recovery PA P A P A PA P A P A P A A PA Determines in advance the actions taken for warning or failure events on intrusion fans temperatures voltages power supplies memory and redundancy Allows the administrator to clear the alert log Enters and edits cost of ownership information for the system including values for depreciation lease maintenance service and support Allows the administrator to clear the command log Allows the administrator to clear the ESM log Enables and disables SNMP traps Sets IP addresses for alert destinations Determines the shutdown action if any taken for a specific platform event Also enables and disables platform events filter alert generation Determines in advance how the system responds to a hung operating system 94 omconfig Managing Components Using the Instrumentation Service Table 4 2 omconfig Command Level 1 Level 2 and Level 3 continued Use Command Command Command Level 3 Level 1 Level 2 shutdown thrmshutdown webserver chassis or mainsystem biossetup fans frontpanel info Allows the administrator to select from several options when shutting down the system Sets th
148. ex Server Administrator displays a summary of status readings and thresholds set for any temperature probes that are present on the system If you specify the index Server Administrator displays a summary for a specific temperature probe omreport chassis volts or omreport mainsystem volts Use the omreport chassis volts or omreport mainsystem volts command to view properties of the system s voltage probes Type omreport chassis volts index n or omreport mainsystem volts index n The index parameter is optional If you do not specify the index Server Administrator displays a summary of status readings and thresholds set for any voltage probes that are present on the system If you specify the index Server Administrator displays a summary for a specific voltage probe omreport Viewing System Status Using the Instrumentation Service 69 omreport system Commands or omreport servermodule Commands Use the omreport system or omreport servermodule command to view logs threshold values cost of ownership information and information about how shutdown actions and recovery actions are configured omreport system or omreport servermodule Use the omreport system or omreport servermodule command to see a general status of the components of the system When you specify a level 3 command such as omreport system shutdown or omreport servermodule shutdown you get detailed information for one system component rather than the high leve
149. f lt user gt the system omconfig system or servermodule assetinfo Editing Cost of Ownership Values Example Command for Adding System Information To provide a value for a system parameter type a command of the form omconfig system assetinfo info system lt name yvalue pair 2 gt or omconfig servermodule assetinfo info system lt name value pair 2 gt For example type omconfig system assetinfo info system location firstfloor Or omconfig servermodule assetinfo info system location firstfloor The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to name value pair 1 For an example see Example Commands for Adding Acquisition Information on page 179 Adding Warranty Information Use the omconfig system warranty or omconfig servermodule warranty command to assign values for warranty information A warranty is a contract between the manufacturer or dealer and the purchaser of a system The warranty identifies the components that are covered for repair or replacement for a specified length of time or usage For details on editing extended warranty values see Adding Extended Warranty Information on page 181 Table 5 12 lists the valid parameters for adding warranty information omconfig system or servermodule assetinfo Editing
150. fo or omreport mainsystem info Use the omreport chassis info or omreport mainsystem info command to see a summary of installed component versions Type omreport chassis info index n or omreport mainsystem info index n 52 omreport Viewing System Status Using the Instrumentation Service The index parameter specifies a chassis number and is optional If you do not specify the index Server Administrator displays summary chassis information for each chassis If you specify the index Server Administrator displays summary information for a specific chassis K NOTE If iDRAC is installed Server Administrator displays the LCC version If BMC is installed Server Administrator displays the USC version Depending on the system s configuration you may notice the following output Index 21 0 Chassis Name Main System Chassis Host Name WIN 27CO2UQ0FV6L iDRAC7 Version 1 00 Chassis Model PowerEdge R720 Chassis Lock Present Chassis Service Tag 7654321 Express Service Cod 15608862073 Chassis Asset Tag G omreport chassis intrusion Use the omreport chassis intrusion command to find out whether the cover of the system is open or not Server Administrator tracks chassis intrusion events because intrusions may indicate an attempt to steal a system component or to perform unauthorized maintenance on the system Type omreport chassis intrusion omreport Viewing System Status Using the Instrumentatio
151. g Managing Components Using the Instrumentation Service 109 Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems continued name value pair1 name value pair 2 Description attribute setting attribute setting on off on Uses the keypad as number keys numlock off Uses the keypad as arrow keys attribute numa setting enabled disabled enabled Enables Node Interleaving disabled Disables Node Interleaving attribute setting off Iptl off Disables the parallel port address ppaddress Ipt2 Ipt3 Ipt1 Locates the device on LPT1 Ipt2 Locates the device on LPT72 Ipt3 Locates the device on LPT3 attribute setting at ps2 ecp at Sets the parallel port mode to AT ppmode epp ps2 Sets the parallel port mode to PS 2 ecp Sets the parallel port mode to ECP extended capabilities port epp Sets the parallel port mode to EPP enhanced parallel port attribute setting on off CAUTION If you modify the setting for primaryscsi force true primary scsi romb romba or rombb the system becomes inoperable until you reinstall the operating system on Enables the primary SCSI off Disables the primary SCSI force true Verification of setting change 110 l omconfig Managing Components Using the Instrumentation Service Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems continued name value pair 1 attribute name val
152. gh Server Administrator omconfig chassis fans or omconfig mainsystem fans Use the omconfig chassis fans or omconfig mainsystem fans command to set fan probe warning thresholds As with other components you can view both warning and failure threshold values but you cannot set failure thresholds The system manufacturer sets the minimum and maximum failure thresholds Valid Parameters for Fan Warning Thresholds Table 4 5 lists the valid parameters for setting fan warning thresholds Table 4 5 Parameters of omconfig chassis fans or omconfig chassis fans name value pair Description index lt n gt Number of the probe or probe index must specify warnthresh default Sets the minimum and maximum warning thresholds to default minwarnthresh lt n gt Minimum warning threshold maxwarnthresh lt n gt Maximum warning threshold 124 omconfig Managing Components Using the Instrumentation Service Default Minimum and Maximum Warning Thresholds K NOTE Systems that contain ESM3 ESM4 and BMC capabilities do not allow you to set warning threshold values to default values To set both the upper and lower fan warning threshold values to the recommended default value type omconfig chassis fans index 0 warnthresh default or omconfig mainsystem fans index 0 warnthresh default K NOTE You cannot default one value and set another In other words if you default the minimum warning threshold value yo
153. gt fmt lt format option gt For example type omreport system summary fmt tbl or omreport servermodule summary fmt tbl where fmt tbl specifies table format You can combine the formatting option with the option to direct output to a file For example type omreport system summary fmt tbl outa summary txt or omreport servermodule summary fmt tbl outa summary txt where fmt tbl specifies table format and outa specifies that you append the command results to a file called summary txt List Ist The default format is Ist or list format Use this format when you want to optimize output for simple readability You need to specify a format for the command output only if you want a format other than the Ist format Working With CLI Command Results 299 300 To see the following example command output in Ist format type omreport system summary or omreport servermodule summary No special formatting option is required because list format is the default display format The network data part of the example system summary is displayed as follows Network Data Network Interface 0 IP Address 143 166 152 108 Subnet Mask 255 255 255 0 Default Gateway 143 166 152 1 AC Address 00 02 b3 23 d2 ca Table tbl Use the tbl or table formatting option to have the data formatted in table rows and columns To see the following example command output in table format type omreport system summary fmt tbl
154. gt variable specifies the physical disk 226 omconfig storage Commands To obtain these values type omreport storage controller to display the controller Ds and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To cancel replace member operation on disk 0 0 1 which is connected to controller 0 type omconfig storage pdisk action cancelreplacemember controller 0 pdisk 0 0 1 omconfig Clear Physical Disk Use the following omconfig command to clear data or a configuration from a physical disk Complete Syntax omconfig storage pdisk action clear controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller Ds and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To clear the physical disk 3 on connector 0 of controller 1 e For SCSI SATA and ATA controllers omconfig storage pdisk action clear controller 1 pdisk 0 2 3 omconfig Cancel Clear Physical Disk Use the following omconfig command to cancel a clear operation in progress on a physical disk omconfig storage Commands 227 Complete Syntax omconfig storage pdisk action cancelclear controller id pdisk lt PDISKID gt where id is the controll
155. hat the cache can hold in kilobytes Installed Size is the actual size of the cache Type indicates whether the cache is primary or secondary Location is the location of the cache on the processor or on a chipset outside the processor 60 omreport Viewing System Status Using the Instrumentation Service A Write Policy describes how the cache deals with a write cycle In a write back policy the cache acts like a buffer When the processor starts a write cycle the cache receives the data and stops the cycle The cache then writes the data back to the main memory when the system bus is available In a write through policy the processor writes through the cache to the main memory The write cycle does not complete until the data is stored into the main memory Associativity refers to the way in which main memory content is stored on the cache e A fully associative cache allows any line in main memory to store at any location in the cache e An way set associative cache directly maps n specific lines of memory to the same n lines of cache For example line 0 of any page in memory is stored in line 0 of cache memory Cache Device Supported Type is the type of static random access memory SRAM that the device can support Cache Device Current Type is the type of the currently installed SRAM that the cache is supporting External Socket Name Silk Screen Name is the name printed on the system board next to the socket Err
156. he LAN channel omconfig Managing Components Using the Instrumentation Service 147 Table 4 12 Parameters of omconfig chassis remoteaccess or omconfig mainsystem remoteaccess continued name value pair 1 name value pair 2 Description config id user id id user id User ID of the user dracusergroup admin being configured poweruser guest dracusergroup admin Enables the custom none Administrator user privileges dracusergroup poweruser Enables the Power User privileges dracusergroup guest Enables the Guest User privileges dracusergroup custom Enables the Custom User privileges NOTE See Table 4 13 for more information on dracusergroup custom dracusergroup none Does not enable user privileges config user id user id id user id User ID of the user continued extipmiusergroup admin being configured operator readonly extipmiusergroup admin Enables the custom none Administrator user privileges NOTE extipmiusergroup user group is available only on Dell yx0x Blade systems extipmiusergroup readonly Enables the Read Only privileges extipmiusergroup operator Enables the Operator privileges extipmiusergroup custom Enables the Custom User privileges NOTE It is recommended that you use the operator and readonly options for systems with iDRAC Enterprise NOTE See Table 4 14 for more information on extipmiusergroup custom extipmiusergroup none Does not en
157. he BIOS firmware systems management software and operating system installed on the system 88 omreport Viewing System Status Using the Instrumentation Service Example Command Output Type omreport system version Or omreport servermodule version K NOTE If iDRAC is installed Server Administrator displays the LCC version If BMC is installed Server Administrator displays the USC version The output that is displayed in the CLI window depends on the version of the BIOS RAID controllers and firmware installed on the system The following partial command results are unique and may not resemble the results for the configuration of the system Version Report Main System Chassis Name BIOS Version 0S9 Name iDRAC7 Version 1 00 Software Name icrosoft Windows Server 2008 R2 Enterprise x64 edition Version Version 6 1 Build 7600 x64 Server Full Installation Name Dell Server Administrator Version TeX eX omreport Viewing System Status Using the Instrumentation Service 89 90 Storage Controller Firmware Name PERC H310 Mini Version 20 10 1 0025 omreport preferences Commands Use the omreport preferences command to view the URL information of the Server Administrator Web server Table 3 9 lists the available attributes Table 3 9 Attributes of omreport preferences webserver name value pair Description attribute geturl Reports the URL information of the
158. he virtual disks attached to the controller Example Syntax To resume a check consistency on virtual disk 4 on controller 1 type omconfig storage vdisk action resumecheckconsistency controller 1 vdisk 4 omconfig Blink Virtual Disk Use the following omconfig command syntax to blink the physical disks included in a virtual disk Complete Syntax omconfig storage vdisk action blink controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Example Syntax To blink the physical disks in virtual disk 4 on controller 1 type omconfig storage vdisk action blink controller 1 vdisk 4 omconfig storage Commands 235 omconfig Unblink Virtual Disk Use the following omconfig command syntax to unblink the physical disks included in a virtual disk Complete Syntax omconfig storage vdisk action unblink controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller Ds and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Example Syntax To unblink the physical disks in virtual dis
159. iasnameN Processor Settings attribute DataReuse attribute DculpPrefetcher attribute DcuStreamerPrefetcher attribute LogicalProc attribute Proc Brand attribute ProcllId attribute Procl L2Cache attribute ProclL3Cache attribute Procl NumCores attribute Proc2Brand attribute Proc2Id attribute Proc2L2Cache attribute Proc2L3Cache setting Enabled Disabled setting Enabled Disabled setting Enabled Disabled setting Enabled Disabled setting lt string gt setting lt string gt setting lt string gt setting lt string gt setting lt integer gt setting lt string gt setting lt string gt setting lt string gt setting lt string gt omconfig Managing Components Using the Instrumentation Service 117 118 Table 4 4 BIOS Setup Settings on PowerEdge yx2x Systems continued Group name value pair 1 attribute name value pair 2 setting Processor Settings continued attribute Proc2NumCores attribute Proc3Brand attribute Proc3Id attribute Proc3L2Cache attribute Proc3L3Cache attribute Proc3NumCores attribute Proc Brand attribute Proc4ld attribute Proc L2Cache attribute Proc L3Cache attribute ProctNumCores attribute Proc64bit attribute ProcAdjCacheLine attribute ProcBusSpeed attribute ProcCores attribute ProcCoreSpeed attribute ProcExecuteDisable attribute ProcHwPrefetcher attribute ProcVirtualization attribute OpiBandwidthPriority
160. ical disk The pdisk lt PDISKID gt parameter indicates a physical disk by specifying either connector enclosureID targetID or connector targetID stripesize lt 2kb 4kb 8kb 16kb 32kb 64kb 128kb gt Parameter Optional Different controllers support different stripe sizes See the Dell OpenManage Online Help for more information on stripe sizes supported for a controller All stripe sizes are specified in kilobytes For example when specifying 128 KB as the stripe size type stripesize 128kb 258 omconfig storage Commands cachepolicy lt d c gt Parameter Optional Different controllers support different cache policies Table 8 7 indicates how to specify the cachepolicy lt d c gt parameter for each of the cache policies Table 8 7 Cache Policy Parameters Cache Policy cachepolicy d c Parameter Specification Direct I O cachepolicy d Cache I O cachepolicy c diskcachepolicy lt disabled enabled gt Parameter Optional Different controllers support different disk cache policies The following table indicates how to specify the diskcachepolicy lt disabled enabled gt parameter for each of the cache policies Table 8 8 Disk Cache Policy Parameters Disk Cache Policy diskcachepolicy disabled enabled Parameter Specification Disabled diskcachepolicy disabled Enabled diskcachepolicy enabled readpolicy lt ra nra ara rc nrc gt Parameter Optional Different co
161. ig Managing Components Using the Instrumentation Service omconfig preferences snmp Setting the SNMP root password allows administrators to restrict access to SNMP set operations that allow important systems management interventions You can configure the SNMP root password normally by typing all of the parameters in one command line or interactively Using the omconfig preferences snmp command you can also configure SNMP set operations K NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator A CAUTION Interactive mode is the more encrypted method of setting the SNMP root password In non interactive mode the values you type for the newpw and confirnnewpw options appear on the system s monitor In the interactive mode the values you type for passwords are masked The parameters for configuring the SNMP root password are the same whether you configure it interactively or non iteratively NOTE If you specify setting rootpw but do not specify the other name value pair parameters you enter interactive mode and the command line prompts you for the remaining values Table 4 18 lists the valid parameters for the command Table 4 18 SNMP Root Password Parameters name value pair Description setting rootpw Required oldpw lt oldpassword gt Enter the old SNMP root password newpw lt newpass
162. ig command syntax to stop the patrol read task on the controller Complete Syntax omconfig storage controller action stoppatrolread controller id where id is the controller ID as reported by the omreport storage controller command Example Syntax To stop the patrol read task on controller 1 type omconfig storage controller action stoppatrolread controller 1 K NOTE To stop patrol read the current patrol read mode is set to Manual omconfig Create Cachecade Use the following omconfig storage command syntax to create a cachecade on the given controller Complete Syntax omconfig storage controller action createcachecad controller id pdisk lt PDISKID gt name lt string gt where id is the controller ID as reported by the omreport storage controller command and PDISKID is specified as pdisk connector enclosureID targetID connector targetID Example Syntax To create a cachecade on controller 0 type omconfig storage controller action createcachecad controller 0 pdisk 0 2 3 name Cachecadel omconfig storage Commands 271 omconfig Enable LKM Controller Use the following omconfig storage command syntax to enable the LKM mode and create the encryption key for the controller Complete Syntax omconfig storage controller action enablelkm controller id keyid lt keyid string gt passphrase lt passphrase string gt escrow yes filepath lt Absolute path to the escrow file gt where
163. in the command line interface CLI The symbol often called pipe is the logical exclusive or operator For example enable disable means enable or disable the component or feature Command Summary of the omreport Command Although this chapter lists all possible omreport commands the commands available on the system depend on the system configuration The results of the omreport command may vary from one system to another The omreport command displays data for the installed components only K NOTE When a system includes an external chassis the displayed results vary by operating system On SUSE Linux Enterprise Server and Red Hat Enterprise Linux systems omreport commands display external chassis information in a separate section after the main chassis information On Microsoft Windows systems data about the external chassis does not appear in the omreport output Table 3 2 provides a high level summary of the omreport command The column titled Command level 1 shows the omreport command at its most general use Command level 2 shows the major objects or components that you can view using omreport about chassis storage and system Command level 3 lists the specific objects and components to view reports User privilege required refers to the type of privilege you need to run the command where U User P Power User and A Administrator Use is a very general statement about the actions performed using omreport More details
164. in the values for the connector enclosure and physical disk targetID type omreport storage controller to display the controller Ds and then type omreport storage pdisk controller id to display the IDs for the physical disks attached to the controller Using the Storage Management Service 199 Table 6 2 Syntax For of Parameters continued Syntax Description battery id Indicates the battery ID as reported by the omreport command To obtain this value type omreport storage controller to display the controller IDs and then type omreport storage battery controller id to display the ID for the controller battery lt gt The caret symbols lt gt enclose variable elements that you must specify For example the name lt string gt parameter is specified as name VirtualDisk1 The bracket symbols indicate optional elements that you can choose whether or not to specify For example when creating a virtual disk the name lt string gt parameter indicates that you have the option of specifying the virtual disk name If you omit this parameter from the syntax then a default name for the virtual disk is chosen for you The pipe symbol separates two or more options from which one only is selected For example when creating a virtual disk the cachepolicy d c indicates that the cache policy is specified as either cachepolicy d or cachepolicy c User Privileges for omreport storage and
165. index 0 outa fans txt or omreport mainsystem fans index 0 outa fans txt Fans txt now reads as follows Index 2 0 Status OK Probe Name System Board Fan 1 RPM Reading 2380RPM Minimum Warning Threshold 600RPM Maximum Warning Threshold 5700RPM Minimum Failure Threshold 500RPM Maximum Failure Threshold 6000RPM Index 0 Status OK Probe Name System Board Fan 1 RPM Reading 3001RPM Minimum Warning Threshold 7OORPM Maximum Warning Threshold 5500RPM Minimum Failure Threshold 500RPM Maximum Failure Threshold 6000RPM You can use a text editor to insert the time that each block of data was captured In comparing the two snapshots for fan probe 0 you can see that the second report shows several changes The reading of fan RPM has been changed to 3001RPM but is still within normal range Someone has raised the minimum warning threshold to 700 RPM and has decreased the maximum warning threshold to 5500 RPM 298 Working With CLI Command Results Selecting a Format for the CLI Command Output You can specify a format for the CLI command results The format determines how the command output is displayed If the command results are directed to a file the format is captured by the file to which you write the command results The available formats include e List Ist e Semicolon separated values ssv e Table tbl e Custom delimited format cdv The Syntax for the formatting option is lt command
166. ing the omreport command see omreport Viewing System Status Using the Instrumentation Service on page 31 omconfig Managing Components Using the Instrumentation Service 91 Table 4 1 System Availability for the omconfig Command Command Level 1 Command Level 2 Applicable to omconfig servermodule Blade systems mainsystem Blade systems system Rack and Tower systems chassis Rack and Tower systems Conventions for Parameter Tables When listing the parameters that a command can take the parameters are listed in alphabetical order instead of the order in which they appear in the command line interface CLI The symbol often called pipe is the logical exclusive or operator For example enable disable means you can enable or disable the component or feature but you cannot simultaneously enable and disable the component or feature omconfig Command Summary Table 4 2 is a high level summary of the omconfig command The columns titled Command level 2 and Command level 3 list the major arguments that are used with omconfig User privilege required refers to the type of privilege you need to run the command where U User P Power User and A Administrator Use is a very general statement about the actions that are performed using omconfig More information about the syntax and use of the omconfig command appear later in this section K NOTE Although the table lists all possible omconfig commands the commands avai
167. inued Parameters Description User accessible USB Displays whether the user accessible USB port is enabled or Ports disabled CPU Virtualization Displays the additional hardware capabilities provided by Technology Virtualization Technology AC Power Recovery Mode Displays the system state when input power is restored after an outage Embedded SATA Displays whether the embedded SATA controller is set to Controller ATA mode RAID mode or is disabled SATA Port 0 Displays the state of SATA port 0 SATA Port 1 Displays the state of SATA port 1 Dual NIC 1 2 Displays whether NIC 1 and NIC 2 with PXE iSCSIT is enabled or disabled Dual NIC 3 4 Displays whether NIC 3 and NIC 4 with PXE iSCSIT is enabled or disabled NIC 1 Displays whether the first NIC is enabled with or without PXE SCSI or disabled during system boot NIC 2 Displays whether the second NIC is enabled with or without PXE iSCSI or disabled during system boot NIC 3 Displays whether the third NIC is enabled with or without PXE SCSI or disabled during system boot NIC 4 Displays whether the fourth NIC is enabled with or without PXE iSCSI or disabled during system boot Trusted Cryptographic Displays whether TCM is on or off Module TCM Trusted Platform Displays whether TPM is off on with pre boot Module TPM measurements or on without pre boot measurements Security Internal US
168. ion A service contract is an agreement that specifies fees for preventive maintenance and repair of the system Table 5 9 lists the valid parameters for adding contract information Table 5 9 Parameters of omconfig system assetinfo info service or omconfig servermodule assetinfo info service Command CommandLevel Command Name Name Value Description Level 1 2 Level3 Value Pair1 Pair2 omconfig system or servermodule assetinfo info service renewed Whether the service true false agreement has been renewed type Type of service that the lt string gt contract covers vendor Business entity that lt business gt offers service on the system omconfig system or servermodule assetinfo Editing Cost of Ownership Values 189 Example Command for Adding Service Information To provide a value for a service parameter type a command of the form omconfig system assetinfo info service lt name value pair 2 gt or omconfig system assetinfo info service lt name value pair 2 gt For example type omconfig system assetinfo info service vendor fixsystemco Or omconfig servermodule assetinfo info service vendor fixsystemco The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to name value pair 1 For an example
169. irtual disks 241 rename virtual disk 246 249 replace member virtual disk 245 rescan connector 286 rescan controller 252 reset controller configuration 255 reset temperature probe thresholds 278 280 resume check consistency 235 secure virtual disk 243 set controller rebuild rate 261 set enclosure asset name 277 set enclosure asset tag 276 set temperature probe thresholds 277 system 158 test controller alarm 254 unblink physical disk 220 unblink virtual disk 236 288 omconfig about details true 99 omconfig battery commands 281 omconfig channel commands 286 omcontfig chassis 100 100 biossetup 100 bmc 136 currents 124 fancontrol 126 fans 124 frontpanel 126 info 128 leds 129 memorymode 129 temps 150 volts 152 omcontfig chassis biossetup name value pairs 101 omconfig chassis bmc name value pair 137 omconfig chassis fans name value pairs parameters 124 omconfig chassis frontpanel name value pair parameters 127 omconfig chassis info name value pair parameters 128 omconfig chassis leds name value pairs parameters 129 omconfig chassis memorymode name value pairs parameters 131 omconfig chassis temps name value pairs paramaters 150 omcontfig chassis volts name value pairs parameters 152 omconfig clear virtual disk bad blocks 243 omconfig command 91 omconfig controller commands 249 omconfig Create Cachecade 271
170. is about and the name value pair is details true Many commands use command level 1 command level 2 and command level 3 but do not require any parameters name value pairs Most omreport commands are of this type For example the following command displays a list of alert actions that are configured for components on a system omreport system alertaction The most complex commands have all three command levels and can have multiple name value pairs The following is an example of two name value pairs omconfig system assetinfo info depreciation duration 3 The following is an example of nine name value pairs omconfig system assetinfo info acquisition purchasecost lt n gt waybill lt n gt installdate lt mmddyy gt purchasedate lt mmddyy gt ponum lt n gt signauth lt text gt expensed lt yes no gt costcenter lt text gt 24 Introduction In each chapter of this document command syntax and other information about the commands are formatted using any of the following fields as appropriate command command command name value name value level 1 level 2 level 3 pair 1 pair 2 Introduction 25 26 Introduction Using the omhelp Command The omhelp command and its equivalent lt command gt accesses the detailed help text interface of command line interface CLI You can get help at several levels of detail Each fully qualified CLI command may have a variable number of distinct parts the
171. k 4 on controller 1 type omconfig storage vdisk action unblink controller 1 vdisk 4 omconfig Initialize Virtual Disk Use the following omconfig command syntax to initialize a virtual disk Complete Syntax omconfig storage vdisk action initialize controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller Ds and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Example Syntax To initialize virtual disk 4 on controller 1 type omconfig storage vdisk action initialize controller 1 vdisk 4 236 omconfig storage Commands omconfig Fast Initialize Virtual Disk Use the following omconfig command syntax to fast initialize a virtual disk A CAUTION You may receive a warning message if you attempt to delete the system or boot partition However this warning message is not generated always Ensure that you do not delete the system or boot partition or other vital data when using this command Complete Syntax omconfig storage vdisk action fastinit controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks
172. ks 216 omreport storage Commands omconfig storage Commands The omconfig commands allows you to configure physical disks virtual disks controllers enclosures batteries global information connectors and cachecades The following sections provide the omconfig command syntax required to display the status of various storage components To see a list of valid commands for omconfig storage type omconfig storage Table 8 1 provides the omconfig storage command syntax Table 8 1 Syntax of omconfig storage help Command Command Command Level 3 Use Level 1 Level 2 omconfig storage Sets the storage component properties for which omconfig commands are available pdisk Displays the list of omconfig storage pdisk parameters for configuring physical disks vdisk Displays the list of omconfig storage vdisk parameters for configuring virtual disks controller Displays a list of the omconfig storage controller parameters for configuring controllers enclosure Displays a list of the omconfig storage enclosure parameters for configuring enclosures battery Displays a list of the omconfig storage battery parameters for configuring batteries globalinfo Displays a list of the omconfig storage globalinfo parameters for configuring global storage properties omconfig storage Commands 217 Table 8 1 Syntax of omconfig storage help continued Command Command Command Level 3 Use Level 1 Level 2 conne
173. l and the SUSE Working With CLI Command Results 295 Linux Enterprise Server terminal To display command output with control over scrolling type the CLI command and append the pipe symbol followed by more For example type omreport system summary more or omreport servermodule summary more The multiscreen system summary displays the first screen When you want to see the next screen of command output press the spacebar Writing Command Output to a File When redirecting command results to a file you can specify a filename and a directory path if necessary to which you want to write the command result When specifying the path to which you want to write the file use the syntax appropriate for the operating system You can save command results in two ways You can overwrite any file that has the same name as the output file you specify or you can keep adding results of commands to a file of the same name Saving Command Results to a File That is Overwritten Use the oute option when you want to overwrite data stored in previously written files For example at 11 00 A M you capture fan probe RPM readings for fan probe 0 on the system and write the results to a file called fans txt You type omreport chassis fans index 0 outc fans txt Or omreport mainsystem fans index 0 outc fans txt 296 Working With CLI Command Results Partial results written to the file are Index wO Status OK Probe Name Sys
174. l Disk Commands continued Required Command Levels Optional name value pairs 1 2 3 action cancelreplacemember controller id pdisk lt PDISKID gt action clear controller id pdisk lt PDISKID gt action cancelclear controller id pdisk lt PDISKID gt action enabledevicewritecache controller id pdisk lt PDISKID gt action disabledevicewritecache controller id pdisk lt PDISKID gt action exportlog controller id pdisk lt PDISKID gt action convertraidtononraid controller id pdisk lt PDISKID gt action convertnonraidtoraid controller id pdisk lt PDISKID gt omconfig Blink Physical Disk You can blink the light light emitting diode or LED display on one or more physical disks attached to a controller Use the following omconfig command syntax to blink the LEDs of one or more physical disks Complete Syntax omconfig storage pdisk action blink controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To blink the LEDs of physical disk 0 on connector 0 of controller 1 e For SCSI SATA and ATA controllers omconfig storage Commands 219 omconfig storage pdisk action blink controller 1 pdisk 0 0 e
175. l status obtained with omreport system or omreport servermodule Type omreport system or omreport servermodule If the system has both a main system chassis or main system and at least one direct attached storage device Server Administrator may display a summary that resembles the following example SEVERITY COMPONENT Ok Main System Chassis Critical Storage 70 omreport Viewing System Status Using the Instrumentation Service Commands for Viewing Logs Use the omreport system or omreport servermodule command to view logs the alert log the command log and the hardware or ESM log K NOTE If the Alert log or Command log displays invalid XML data such as when XML data generated for the selection is not well formed you must clear the log and resolve the issue To clear the log type omconfig system alertlog action clear or omconfig system cmdlog action clear If you need to retain the log information for future reference save a copy of the log before clearing See Commands for Clearing Logs on page 163 for more information about clearing logs To view the contents of the alert log type omreport system alertlog or omreport servermodule alertlog To view the contents of the command log type omreport system cmdlog or omreport servermodule cmdlog To view the contents of the ESM log type omreport system esmlog Or omreport servermodule esmlog omreport Viewing System
176. lable on the system depend on the system configuration If you try to get help or execute a command for a component not installed on the system Server Administrator displays a message that the component or feature is not found on the system K NOTE When CSIOR Collect System Inventory on Restart is disabled omconfig does not allow to configure the BIOS settings 92 omconfig Managing Components Using the Instrumentation Service Table 4 2 omconfig Command Level 1 Level 2 and Level 3 Command Command Command Level3 User Use Level 1 Level 2 Privilege Required omconfig about U PA Shows version number and properties for the Server Administrator program details true U PA Displays information for all of the Server Administrator programs that are installed preferences cdvformat A Specifies the delimiter for separating data fields reported in custom delimited format cdv dirservice A Configures the Microsoft Active Directory service snmp A Sets the SNMP root password Configures SNMP Set Operations useraccess A Determines whether users below the administrator level are allowed to use Server Administrator or not webserver A Allows the administrator to system or servermodule set the encryption levels of the Web server and configure the URL launch point in the Server Administrator Web server environment omconfig Managing Components Using the Instrumentation Service 93 Table 4 2 omconfig Command Level 1 L
177. lar omconfig system command For example the following commands produce a list of valid parameters for omconfig system alertaction and omconfig system shutdown omconfig system alertaction omconfig system shutdown In case of the omconfig system alertaction command you can use various options to prevent all of the CLI help from scrolling before you can read it To scroll the command output one screen at a time type omconfig system alertaction more where more allows you to press the spacebar to see the next screen of the CLI help output To create a file that contains all the help for the omconfig system alertaction command type omconfig system alertaction outa alert txt where outa directs the output of the command to a file called alert txt To read the help for the alertaction command on Microsoft Windows Red Hat Enterprise Linux or SUSE Linux Enterprise Server operating systems type more alert txt omconfig about Use the omconfig about command to learn the product name and version number of the systems management application installed on the system The following is an example output of the omconfig about command Product Dell OpenManage Server Administrator name Version E we cn Copyright Copyright C Dell Inc xXxxx xxxx All rights reserved Company Dell Inc 98 omconfig Managing Components Using the Instrumentation Service For more details about the environment for Serve
178. latform event filter index number Sets the index for the destination ipaddress ipv Sets the IP address for the destination ipv6 address communitystr text Sets the text string that acts as a password and is used to authenticate SNMP messages sent between the BMC and the destination management station omcontfig system platformevents or omconfig servermodule platformevents Use the omconfig system platformevents or omconfig servermodule platformevents command to configure shutdown action if any taken for a specific platform event You can also enable or disable platform event filter alert generation A CAUTION If you set a platform event shutdown action to anything other than none or power reduction the system is forcefully shutdown when the specified event occurs This shutdown is initiated by firmware and is carried out without first shutting down the operating system or any of the applications running on your system 164 omconfig Managing Components Using the Instrumentation Service Table 4 25 lists the valid parameters for the command NOTE Alert settings are mutually exclusive and you can set one at a time only The action settings are also mutually exclusive and you can set one at a time only However alert and action settings are not mutually exclusive of each other Table 4 25 Parameters for Alert Action Command Action Description action disable Disables the SNMP alert action enab
179. le Disables IPv6 stack to unload on iDRAC NOTE This option requires license to enable or disable ipv6 If the appropriate license is not installed or has expired the system displays an error message For more information see 7he Dell License Manager at dell com support manuals characcuminterval number config advsol charsendthreshold number enableipmi true false enablenic true false omconfig Managing Components Using the Instrumentation Service number Sets the character accumulate interval in 5 millisecond intervals number Sets the number of characters BMC automatically sends a serial over LAN data packet that contains the number of characters as soon as this number of characters or greater has been accepted from the baseboard serial controller into the BMC true Enables IPMI over LAN false Disables IPMI over LAN true Enables DRAC NIC false Disables DRAC NIC NOTE The enablenic option is supported only on PowerEdge x9xx systems that have DRAC 5 installed 137 Table 4 12 Parameters of omconfig chassis remoteaccess or omconfig mainsystem remoteaccess continued name value pair 1 name value pair 2 Description config nicselection sharedwithfailoveronall Configures the sharedwithfailoveronall new NIC selection option nicl teamednic nic2 le nicl Enables NIC 1 dracnic teamedniclnic2 Enables NIC teaming functionality dracnic Enables DRAC NIC if DRAC 5 is i
180. le Enables the SNMP alert action none Takes no action when the system is hung or has crashed action powercycle Turns off the electrical power to the system pauses turns the power on and reboots the system action poweroff Turns off the electrical power to the system action Reduces the processor speed until the power consumption powerreduction comes down and reaches below the warning threshold If the system power consumption stays below the warning threshold increases the processor speed NOTE This action is applicable only for PowerEdge Rack and Tower systems earlier than PowerEdge yx x systems action reboot Forces the operating system to shut down and initiates system startup performs BIOS checks and reloads the operating system Table 4 26 lists the components and events for which you can set platform events Components are listed in alphabetical order except that warning events always precede failure events for a component omconfig Managing Components Using the Instrumentation Service 165 Table 4 26 Parameters of omconfig system platformevents Event Name Description alertsenable true false true Enables generation of platform event filter alerts false Disables generation of platform event filter alerts NOTE This setting is independent of the individual platform event filter alert settings For a platform event filter to generate an alert both the individual aler
181. le assetinfo Editing Cost of Ownership Values 195 196 omconfig system or servermodule assetinfo Editing Cost of Ownership Values Using the Storage Management Service The Storage Management command line interface CLI enables you to perform reporting configuration and management functions of Storage Management from an operating system command shell The Storage Management CLI also enables you to script command sequences The Storage Management CLI provides expanded options for the Dell OpenManage Server Administrator omreport and omconfig commands For more information see the Dell OpenManage Server Administrator Installation Guide and Dell OpenManage Management Station Software Installation Guide See the Storage Management online Help or the Dell OpenManage Server Administrator Storage Management User s Guide for more information on Storage Management CLI Command Syntax Like all Server Administrator commands the omreport and omconfig command syntax consists of specifying command levels The first command level is the command name omreport or omconfig Subsequent command levels provide a greater degree of specification regarding the type of object on which the command operates or the information that the command displays For example the following omconfig command syntax has three levels omconfig storage pdisk Using the Storage Management Service 197 Table 6 1 describes these command levels Table 6 1 Example
182. lete a virtual disk A CAUTION Deleting a virtual disk destroys all information including file systems and volumes residing on the virtual disk You may receive a warning message if you attempt to delete the system or boot partition However this warning message is not generated always Ensure that you do not delete the system or boot partition or other vital data when using this command Complete Syntax omconfig storage vdisk action deletevdisk controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller In some circumstances you may receive a warning message if this command deletes the system or boot partition You can override this warning by using the force yes parameter In this case the syntax is as follows omconfig storage vdisk action deletevdisk controller id vdisk id force yes 240 omconfig storage Commands Example Syntax To delete virtual disk 4 on controller 1 type omconfig storage vdisk action deletevdisk controller 1 vdisk 4 omconfig Format Virtual Disk Use the following omconfig command syntax to format a virtual disk Complete Syntax omconfig storage vdisk action format controller id vdisk id where id is the controller ID and virtual
183. low of communication through the serial port rtscts RTS is ready to send and CTS is clear to send 142 omconfig Managing Components Using the Instrumentation Service Table 4 12 Parameters of omconfig chassis remoteaccess or omconfig mainsystem remoteaccess continued name value pair 1 name value pair 2 config Description mode directbasic directterminal directbasicterminal modembasic modemterminal modembasicterminal config serial continued privilegelevel administrator operator user omconfig Managing Components Using the Instrumentation Service directbasic Type of messaging used for IPMI messaging over a serial connection directterminal Type of messaging that uses printable ASCII characters and allows a limited number of text commands over a serial connection directbasicterminal Both basic and terminal mode messaging over a serial connection modembasic Type of messaging used for IPMI messaging over a modem modemterminal Type of messaging that uses printable ASCII characters and allows a limited number of text commands over a modem modembasicterminal Both basic and terminal messaging over a modem NOTE All commands are not supported on the system administrator Sets the maximum privilege level that is accepted on a serial connection to Administrator operator Sets the maximum privilege level that is accepted on a serial connection to Operator
184. lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller K NOTE To convert multiple non RAID to RAID on a given controller use omconfig storage controller action convertnonraidtoraid command For more information see omconfig Convert Multiple Non RAID to RAID on page 273 Example Syntax To convert non RAID to RAID on physical disk 3 on connector 0 of controller 1 e For SAS controllers omconfig storage pdisk action nonraidtoraid controller 1 pdisk 0 2 3 K NOTE On a SAS controller the physical disk resides in enclosure 2 omconfig storage Commands 231 omconfig Virtual Disk Commands The following sections provide the omconfig command syntax required to execute virtual disk tasks VAN CAUTION The omconfig storage vdisk action deletevdisk controller id vdisk id command deletes a virtual disk Deleting a virtual disk destroys all information including file systems and volumes residing on the virtual disk Table 8 3 omconfig Manage Virtual Disk Commands Required Optional name value pairs Command Levels 1 2 3 omconfig storage vdisk action checkconsistency controller id vdisk id action cancelcheckconsistency controller id vdisk id action pausecheckconsistency controller id vdisk id action re
185. m service tag information config NA Sets the remote access Pv information remoteaccessipv config NA Sets the remote access Pv6 information remoteaccessipv6 config NA Sets the remote access MAC address remoteaccessmac config ipv4idrac Sets IPv4 DRAC information config ipv6idrac Sets IPv6 DRAC information config macidrac NA Sets the DRAC s MAC address config ambienttemp NA Sets the system temperature in centigrade security modity NA Allows you to modify the LCD text security view NA Provides read only access to the LCD text security disabled NA Provides limited access to the LCD text remoteindication true NA LCD flashes when the system detects an active remote session K NOTE The options ipv4idrac ipv6idrac and macidrac are deprecated omconfig Managing Components Using the Instrumentation Service 127 omconfig chassis info or omconfig mainsystem info Use the omconfig chassis info or omconfig mainsystem info command to enter an asset tag name and a chassis name for the system For a Blade systems enter asset tag names for modular components as well Table 4 7 lists the valid parameters for the command Table 4 7 Parameters of omconfig chassis info or omconfig mainsystem info name value pair Description index lt n gt Number of the chassis whose asset tag or name you are setting tag lt text gt Asset tag in the form of alphanumeric text Asset tag should not exceed 10 characters
186. management controller id spindownunconfigureddrives lt enabled disabled gt spindownhotspares lt enabled disabled gt spindownconfigureddrives lt enabled disabled gt idlec lt enabled disabled gt spindowntimeinterval lt 30 to 1440 gt minutes spinupstarttime lt HH MM AM PM gt spinuptimeinterval lt 1 to 24 gt hours NOTE Specify spinupstarttime and spinuptimeinterval only when you set spindownconfigureddrives enabled action setpatrolreadmode controller id mode lt manual auto disable gt action startpatrolread controller id action stoppatrolread controller id action createcachecade controller id pdisk lt PDISKID gt name lt string gt action enablelkm controller id keyid lt keyid gt passphrase lt passphrase string gt escrow yes filepath lt Absolute path to the escrow file gt NOTE If you set escrow yes specify the escrow file path omconfig storage Commands 251 Table 8 4 omconfig Controller Commands continued Required Command Levels Optional name value pairs 1 2 3 action switchtolkm controller id keyid lt keyid gt passphrase lt passphrase string gt escrow yes filepath lt Absolute path to the escrow file gt NOTE If you set escrow yes specify the escrow file path action rekeylkm controller id action convertraidtononraid controller id pdisk lt PDISKID gt action convertnonraidtoraid controller id pdisk lt PDISKID gt omconfig Rescan Con
187. mands omreport Power Supply Status Table 7 8 describes the syntax for the omreport power supply commands Table 7 8 omreport Power Supply Commands Required Command Levels 1 Optional name value pairs Use 2 3 and name value pair omreport storage Displays property enclosure information for all enclosures attached to the system controller id enclosure Displays the information lt ENCLOSUREID gt about the power supplies for info pwrsupplies the specific enclosure where id is the controller number and ENCLOSUREID is the enclosure number For example controller 0 enclosure 2 controller id enclosure Displays the specified power lt ENCLOSUREID gt supply info pwrsupplies index n where id is the controller number and ENCLOSUREID is the enclosure number and n is the number of a power supply For example controller 0 enclosure 2 info pwrsupplies index 1 omreport storage Commands 209 omreport EMM Status K NOTE The status of the EMMs is displayed as degraded if there is a mismatch between the EMM firmware Table 7 9 describes the syntax for the omreport EMM commands Table 7 9 omreport EMM Commands Required Command Levels Optional name value pairs Use 1 2 3 and name value pair omreport storage enclosure Displays property information for all enclosures attached to the system controller id enclosure Displays the information lt ENCLOSUREID gt about the e
188. n Service 53 A message that resembles the following is displayed Intrusion Information Health Ok Index 0 Status OK Probe Name Intrusion State Chassis is closed omreport chassis leds or omreport mainsystem leds Use the omreport chassis leds or omreport mainsystem leds command to find out whether clear hard drive fault is supported and what severity level lights up the LED Type omreport chassis leds index n or omreport mainsystem leds index n The index parameter is optional If you do not specify the index Server Administrator displays a summary of LED information for chassis 0 If you specify the index Server Administrator displays a summary for a specific chassis The following is an example output Main System Chassis Flash chassis identify LED state gt Off Flash chassis identify LED timeout value 300 54 omreport Viewing System Status Using the Instrumentation Service omreport chassis memory or omreport mainsystem memory Use the omreport chassis memory or omreport mainsystem memory to view details for each memory module slot in the system If the system supports redundant memory this command also displays the status state and type of memory redundancy implemented on the system Type omreport chassis memory index n or omreport mainsystem index n The index parameter is optional If you do not specify the index Server Administrator displays information for all memory mod
189. n gt Sets the minimum warning threshold values one decimal place maxwarnthresh lt n gt Sets the maximum warning threshold values one decimal place 150 l omconfig Managing Components Using the Instrumentation Service Setting the Minimum and Maximum Warning Threshold Values to Default To set both the maximum and minimum temperature warning threshold values to the recommended default value type omconfig chassis temps index 0 warnthresh default or omconfig mainsystem temps index 0 warnthresh default K NOTE You cannot default one value and set another In other words if you set the minimum warning threshold value to the default value you are also selecting the default value for the maximum warning threshold value You cannot default one value and set another In other words if you set the minimum warning threshold value to the default value you are also selecting the default value for the maximum warning threshold value K NOTE The capabilities for managing sensors vary by systems Specifying a Value for the Minimum and Maximum Warning Thresholds To specify values for the temperature probe warning thresholds you must specify the number of the probe you are configuring and the minimum and or maximum warning threshold value In the following example the probe that is being configured is probe 4 omconfig chassis temps index 4 minwarnthresh 11 2 maxwarnthresh 58 7 or omconfig mainsystem temps index
190. n or off USB or USBB Displays whether the USB port is enabled or disabled Secondary SCSI Displays whether the device is enabled or disabled Serial Communications Displays whether COM port 1 and COM port 2 are off or on with or without console redirection Console Redirection After Boot Displays whether console redirection after system reboot is enabled or disabled External Serial Connector Displays whether the external serial connector is mapped to Serial Device 1 Serial Device 2 or a Remote Access Device Console Redirection Failsafe Baud Rate Displays the setting for console redirection failsafe baud rate Serial Address Select Displays port address for the serial devices To view all available boot devices alias names and boot order sequences type omreport chassis biossetup attribute bootorder NOTE In Linux systems user or user groups upgraded to administrator or administrator groups cannot view the boot order sequence omreport Viewing System Status Using the Instrumentation Service 47 Table 3 4 lists the available groups of the BIOS setup parameters on PowerEdge yx2x systems K NOTE Based on the hardware configuration the attributes may vary in a specific group Table 3 4 BIOS Setup Groups on PowerEdge yx2x Systems Group Description BIOS Boot Settings Controls the system boot settings when bootmode is set to bios Boot Settings Control
191. name value pair 2 gt For example type omconfig system assetinfo info lease value 4500 Or omconfig servermodule assetinfo info lease value 4500 The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to name value pair 1 For an example see Example Commands for Adding Acquisition Information on page 179 Adding Maintenance Information Maintenance refers to activities required to keep the system in good working order Table 5 6 lists the valid parameters for adding maintenance information Table 5 6 Parameters of omconfig system assetinfo info maintenance or omconfig servermodule assetinfo info maintenance Command Command Command Name Value Name Value Description Level 1 Level 2 Level3 Pair1 Pair 2 omconfig system or servermodule assetinfo info maintenance enddate Date the extended lt enddate gt warranty agreement ends 184 omconfig system or servermodule assetinfo Editing Cost of Ownership Values Table 5 6 Parameters of omconfig system assetinfo info maintenance or omconfig servermodule assetinfo info maintenance continued Command Command Command Name Value Name Value Description Level 1 Level 2 Level3 Pair1 Pair 2 provider Business entity lt provider gt providing the maintenance servic
192. nclosure info emms management modules where id is the controller EMMs for the specific enclosure number and ENCLOSUREID is the enclosure number For example controller 0 enclosure 2 controller id enclosure Displays the specified lt ENCLOSUREID gt EMMs info emms index n where id is the controller number and ENCLOSUREID is the enclosure number and n is the number of an EMM For example controller 0 enclosure 2 info emms index 1 210 omreport storage Commands omreport Enclosure Slot Occupancy Report Table 7 10 describes the syntax for the omreport enclosure slot occupancy report commands Table 7 10 omreport Enclosure Slot Occupancy Report Commands Required Command Optional name value pairs Use Levels 1 2 3 and name value pair omreport storage Displays property enclosure information for all enclosures attached to the system controller id enclosure Displays the information lt ENCLOSUREID gt about the empty and info pdslotreport occupied slots for the specific enclosure where id is the controller number and ENCLOSUREID is the NOTE This command is not enclosure number supported on Blackplane For example controller 0 SCSI and SWRAID enclosure 2 controllers omreport Battery Status Table 7 11 describes the syntax for the omreport battery commands Table 7 11 omreport Battery Commands Required Command Optional name value pairs Use Levels 1 2 3 omreport
193. nclosure lt ENCLOSUREID gt index id action setalltempprobes controller id enclosure lt ENCLOSUREID gt minwarn n maxwarn n action resetalltempprobes controller id enclosure lt ENCLOSUREID gt action blink controller id enclosure lt ENCLOSUREID gt 274 omconfig storage Commands omconfig Enable Enclosure Alarm Use the following omconfig command syntax to enable the enclosure alarm Complete Syntax omconfig storage enclosure action enablealarm controller id enclosure lt ENCLOSUREID gt where id is the controller ID The lt ENCLOSUREID gt variable specifies the enclosure Example Syntax To enable the alarm on the enclosure attached to connector 2 on controller 1 e For SCSI SATA and ATA controllers omconfig storage enclosure action enablealarm controller 1 enclosure 2 e For SAS controllers omconfig storage enclosure action enablealarm controller 1 enclosure 1 2 omconfig Disable Enclosure Alarm Use the following omconfig command syntax to disable the enclosure alarm Complete Syntax omconfig storage enclosure action disablealarm controller id enclosure lt ENCLOSUREID gt where id is the controller ID The lt ENCLOSUREID gt variable specifies the enclosure omconfig storage Commands 275 Example Syntax To disable the alarm on enclosure 2 attached to connector on controller 1 e For SCSI SATA and ATA controllers omconfig storage enclosu
194. nents Using the Instrumentation Service Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems continued name value pair1 name value pair 2 attribute setting Description attribute nic3 setting enabled enabledwithpxe disabled enabledonly enablednonepxe enabledwithiscsi enabled Enables the third NIC during system boot enabledwithpxe Enables the third NIC during system boot with PXE on if the system has PXE disabled Disables the third NIC during system boot enabledonly Enables the third NIC during system boot with PXE off if the system has PXE enablednonepxe Enables the third NIC during system boot with PXE off if the system has PXE enabledwithiscsi Enables the third NIC during system boot with iSCSI on if the system has iSCSI attribute nic4 setting enabled enabledwithpxe disabled enabledonly enablednonepxe enabledwithiscsi enabled Enables the fourth NIC during system boot enabledwithpxe Enables the fourth NIC during system boot with PXE on if the system has PXE disabled Disables the fourth NIC during system boot enabledonly Enables the fourth NIC during system boot with PXE off if the system has PXE enablednonepxe Enables the fourth NIC during system boot with PXE off if the system has PXE enabledwithiscsi Enables the fourth NIC during system boot with iSCSI on if the system has iSCSI omconfi
195. nfo warranty 194 omconfig system events 168 omconfig system extwarranty 181 omconfig system pedestinations name value pairs parameters 164 omconfig system recovery name value pairs parameters 172 omconfig system shutdown name value pairs parameters 173 omconfig system warranty 193 omconfig system webserver name value pairs parameters 171 omconfig virtual disk commands 232 omhelp 19 27 omreport 39 about 40 battery status 211 chassis 41 command levels 1 2 3 33 command summary 32 connector status 212 controller status 205 EMM status 210 211 enclosure status 206 214 fan status 208 getting help 39 global information 212 physical disk status 202 214 power supply status 209 system 70 temperature probe status 207 virtual disk status 204 omreport chassis acswitch 42 bios 43 biossetup 44 48 currents 48 fancontrol 50 fans 50 firmware 50 frontpanel 51 fru 51 intrusion 53 leds 54 memory 55 nics 56 processors 58 slots 68 temps 69 volts 69 omreport chassis bme name value pairs parameters 68 omreport chassis ports base I O address 58 connector type 58 external name 58 IRQ level 58 Index 311 maximum speed 58 port type 58 omreport chassis processors cache properties 59 connector name 58 core count 59 current speed 59 external clock speed 59 manufacturer 58 processor family 58 processor version 58
196. ng System Status Using the Instrumentation Service Table 3 2 Command Level 1 Level 2 and Level 3 for omreport continued Command Command Level 2 Command User Use Level 1 Level 3 Privilege Required alertlog U P A Allows the administrator to display the alert log assetinfo U P A Displays the cost of ownership information for the system cmdlog U P A Allows the administrator to display the command log esmlog U P A Allows the administrator to display the hardware log events Rac gt Displays the system s Simple Network Management Protocol SNMP event settings operatingsystem U P A Displays the name and version of the operating system pedestinations U P A Displays the destinations to send the configured alerts for platform events platformevents U PA Displays the system s response for each listed platform event recovery PA Displays how the system is configured to respond to a hung operating system shutdown PA Displays how to perform the shutdown action omreport Viewing System Status Using the Instrumentation Service 37 Table 3 2 Command Level 1 Level 2 and Level 3 for omreport continued Command Command Level 2 Level 1 Command Level 3 User Privilege Required Use preferences summary thrmshutdown version webserver U PA U PA U P A Displays the key facts for all system components including main system chassis sof
197. ng omconfig command syntax to set the controller rebuild rate Complete Syntax omconfig storage controller action setrebuildrate controller id rate lt 0 to 100 gt where id is the controller ID as reported by the omreport storage controller command Example Syntax To set the rebuild rate to 50 on controller 1 type omconfig storage controller action setrebuildrate controller 1 rate 50 omconfig storage Commands 261 omconfig Change Controller Properties Use the following omconfig command to change any or all of the following controller properties Complete Syntax omconfig storage controller action setchangecontrollerproperties controller lt id gt bgirate lt rate gt reconstructrate lt rate gt checkconsistencyrate lt rate gt rebuildrate lt rate gt clearredundantpath clear abortcheckconsistencyonerror lt enabled disabled gt loadbalance lt auto disabled gt allowrevertiblehotspareandreplacemember lt enabled disabled gt autoreplacememberonpredictivefailure lt enabled disabled gt persistenthotspare lt enabled disabled gt Example Syntax To enable allow revertible hot spare and replace member operation type omconfig storage controller action setchangecontrollerproperties allowrevertiblehotspare andreplacemember enabled controller 1 omconfig Discard Preserved Cache Use the following omconfig storage command syntax to discard the preserved cache on the controller
198. nstalled NOTE The nicselection option is supported only on PowerEdge x9xx fo yx1x systems From PowerEdge yx2x systems onwards primarynw and failovernw replace nicselection primarynw dedicated dedicated Configures dedicated port as lom1 lom2 lom3 primary network for remote access lom4 NOTE This option requires license to configure primarynw as dedicated If the appropriate license is not installed or has expired the system displays an error message For more information see 7he Dell Licensing Management Guide at dell com support manuals lom 1 Configures lom1 port as the primary network for remote access lom 2 Configures lom2 port as the primary network for remote access lom 3 Configures lom3 port as the primary network for remote access lom 4 Configures lom4 port as the primary network for remote access NOTE The primarynw option is supported from PowerEdge yx2x systems onwards If the primarynw is set to dedicated then set failovernw to none 138 l omconfig Managing Components Using the Instrumentation Service Table 4 12 Parameters of omconfig chassis remoteaccess or omconfig mainsystem remoteaccess continued name value pair 1 name value pair 2 config Description failovernw none lom1 none Configures the failover network to lom2 lom3 lom4 all ipaddress IP subnet Subnet gateway Gateway none lom 1 Configures the failover network to lom
199. ntax The omconfig command syntax for disabling thermal shutdown does not require that you specify a controller or enclosure ID To disable thermal shutdown type the following omconfig storage globalinfo action disablests K NOTE You can use the omreport storage globalinfo command to determine whether smart thermal shutdown is currently enabled or disabled The status of smart thermal shutdown is also displayed in the GUI of Server Administrator To locate this status select the Storage object and the Information Configuration tab 284 omconfig storage Commands omconfig Global Rescan Controller Use the following omconfig command syntax to rescan all controllers on the system See the Dell OpenManage Online Help for more information about Global Rescan Controller Complete Syntax omconfig storage globalinfo action globalrescan Example Syntax The omconfig command syntax for rescanning all controllers on the system does not require that you specify a controller ID To do a global rescan of all controllers type the following omconfig storage globalinfo action globalrescan K NOTE Global rescan is not supported on non RAID SCSI and SAS controllers Reboot the system to make visible the configuration changes on non RAID SCSI controllers omconfig Set Hot Spare Protection Policy Use the following omconfig command syntax to set the hot spare protection policy for dedicated or global hot spares For more information see
200. ntroller command Example Syntax To disable the alarm on controller 1 type omconfig storage controller action disablealarm controller 1 omconfig Quiet Controller Alarm Use the following omconfig command syntax to silence an activated controller alarm For more information see the Dell OpenManage Online Help omconfig storage Commands 253 Complete Syntax omconfig storage controller action quietalarm controller id where id is the controller ID as reported by the omreport storage controller command Example Syntax To quiet the alarm on controller 1 type omconfig storage controller action quietalarm controller 1 omconfig Test Controller Alarm Use the following omconfig command syntax to test the functionality of the controller alarm The alarm sounds for about two seconds See the Dell OpenManage Online Help for more information about Test Controller Alarm Complete Syntax omconfig storage controller action testalarm controller id where id is the controller ID as reported by the omreport storage controller command Example Syntax To test the alarm on controller 1 type omconfig storage controller action testalarm controller 1 254 omconfig storage Commands omconfig Reset Controller Configuration Use the following omconfig command syntax to reset the controller configuration A CAUTION Resetting a configuration permanently destroys all data on all virtual disks attached to the controller
201. ntrollers support different read policies Table 8 9 indicates how to specify the readpolicy lt ra nra ara rc nrc gt parameter for each of the read policies Table 8 9 Read Policy Parameters Read Policy readpolicy ra ara nra re nrc Parameter Specification Read ahead readpolicy ra Adaptive read ahead _ readpolicy ara No read ahead readpolicy nra Read cache readpolicy re No read cache readpolicy nrc omconfig storage Commands 259 writepolicy lt wb wt wc nwc gt Parameter Optional Different controllers support different write policies Table 8 10 indicates how to specify the writepolicy lt wb wt we nwe fwb gt parameter for each of the write policies Table 8 10 Write Policy Parameters Write Policy writepolicy wb wt we fwb nwc Parameter Specification Write back cache writepolicy wb Write through cache writepolicy wt Write cache writepolicy we Force write back writepolicy fwb No write cache writepolicy nwe name lt string gt Parameter Optional Use this parameter to specify a name for the virtual disk For example name VirtualDiskl spanlength lt n gt Parameter Required for RAID 50 and RAID 60 and optional for RAID 10 Use this parameter to specify the number of physical disks in each stripe This parameter applies only to RAID 50 virtual disks If you are not creating a RAID 50 virtual disk do not specify this parameter
202. o the Baseboard Management Controller BMC NIC rac Maps serial port 1 to the Remote Access Controller RAC comlbme Maps serial port 1 to COM port 1 bme NOTE This command is applicable only on selected x8xx systems attribute setting off auto off Disables serial port 2 serialport2 com2 com4 auto Maps serial port 2 to a COM port com2 Maps serial port 2 to COM port 2 com4 Maps serial port 2 to COM port 4 attribute speaker setting on off on Enables the speaker off Disables the speaker attribute cputurbomode setting enabled disabled CPU turbo mode can increase the CPU frequency when the system is operating below the thermal power or current limits enabled Enables CPU Turbo Mode disabled Disables CPU Turbo Mode omconfig Managing Components Using the Instrumentation Service 113 Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems continued name value pair1 name value pair 2 attribute setting Description attribute uausb off setting on backonly on Enables the user accessible USB port s backonly Enables only the user accessible USB port s located at the back of the system off Disables the user accessible USB port s attribute usb setting enabled disabled enabled Enables the USB port s disabled Disables the USB port s NOTE Depending on the system s hardware you can configure either usb or us
203. ocessor family omreport chassis processors 58 processor version omreport chassis processors 58 processors omreport chassis 58 pwrmanagement 62 pwrsupplies omreport chassis 67 read policy parameters 259 rebuild physical disk omcontig 225 reconfiguring virtual disks omcontig 241 reconstruct rate omcontig 265 recovery omcontig system 171 omreport system 80 recovery from a hung operating system 80 rename virtual disk omcontig 246 249 replace member virtual disk omcontig 245 rescan connector omcontig 286 rescan controllers 285 reset all temperature probe thresholds omconfig 280 resume check consistency omconfig 235 S scripting 23 scripting with the CLI 23 secure virtual disk 243 Index 313 service contract information 189 adding 189 set enclosure asset name omconfig 277 set enclosure asset tag omconfig 276 set temperature probe thresholds omconfig 277 280 shutdown omconfig system 173 omreport system 80 shutdown action omconfig system platformevents 165 slot ID omreport chassis slots 69 slots omreport chassis 68 smart thermal shutdown status 212 snmp omcontig preferences 155 SNMP traps 169 disabling 168 enabling 168 start battery learn cycle omconfig 281 state omreport chassis processors 59 storage management CLI 197 successful commands 21 314 Index summary omreport system 80 suppor
204. odule in a given slot number BIOS Location Use Installed Capacity Maximum Capacity Slots Available Slots Used ECC Type Manufacturer BIOS Version Release Date Firmware Name Version omreport Viewing System Status Using the Instrumentation Service 87 Network Data The following details are listed for each NIC and Team interface if Team interface is configured in the system e IP Address Subnet Mask e Default Gateway e MAC Address Storage Enclosures The following details are listed for each storage enclosure attached to the system Name e Service Tag omreport system thrmshutdown or omreport servermodule thrmshutdown Use the omreport system thrmshutdown or omreport servermodule thrmshutdown command to view the properties configured for a thermal shutdown action The three properties that display for thermal shutdown are disabled warning or failure If the CLI displays the following message the thermal shutdown feature has been disabled Thermal protect shutdown severity disabled If the system is configured to shutdown when a temperature probe detects a warning or failure event one of the following messages is displayed Thermal protect shutdown severity warning Thermal protect shutdown severity failure omreport system version or omreport servermodule version Use the omreport system version or omreport servermodule version command to list the version numbers of t
205. of omconfig chassis remoteaccess config user id lt user id gt extipmiusergroup custom or omconfig mainsystem remoteaccess config user id lt user id gt extipmiusergroup custom name value pair 1 name value pair 2 name value pair 3 Description config user id user id loginidrac true true or false Enables extipmiusergroup false or disables logging custom configureidrac into iDRAC NOTE extipmiusergroup true false true or false Enables user group Is available only or disables on the Dell yxOx Blade configuration of systems iIDRAC omconfig chassis temps or omconfig mainsystem temps Use the omconfig chassis temps or omconfig mainsystem temps command to set warning thresholds for temperature probes As with other components you can view both warning and failure threshold values but you cannot set failure threshold values The system manufacturer sets the minimum and maximum failure threshold values K NOTE Threshold values that you can set vary from one system configuration to another Valid Parameters for Temperature Warning Thresholds The following table lists the valid parameters for setting temperature warning thresholds Table 4 15 Parameters of omconfig chassis temps or omconfig mainsystem temps name value pair Description index lt n gt Number of the probe or probe index specify warnthresh default Sets the minimum and maximum warning threshold values to default minwarnthresh lt
206. omconfig system recovery or omconfig servermodule recovery command to set the action when the operating system hangs or crashes You can also set the number of seconds that must pass before the system is considered to have a hung operating system Table 4 30 lists the valid parameters for the command NOTE The upper and lower limits for the timer are dependent on the system model and configuration omconfig Managing Components Using the Instrumentation Service 171 Table 4 30 Recovery Parameters name value pair Description action none Takes no action when the operating system is hung or has crashed action reboot Shuts down the operating system and initiates system startup performing BIOS checks and reloading the operating system action poweroff Turns off electrical power to the system action powercycle Turns off electrical power to the system pauses turns the power on and reboots the system Power cycling is useful when you want to re initialize system components such as hard drives timer lt n gt Number of seconds that must pass before the operating system in a system is considered hung operating system from 20 seconds to 480 seconds Example Recovery Commands To set the action on hung operating system detection to powercycle type omconfig system recovery action powercycle or omconfig servermodule recovery action powercycle To set the system to hang for 120 seconds before a re
207. ommand has changed Change the user scripts as applicable K NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator Components and Events Having View Alert Actions View alert action properties for the following components and events if the components or events are present on the system e Battery Warning e Battery Failure e Chassis Intrusion 72 omreport Viewing System Status Using the Instrumentation Service Current Probe Warning Current Probe Failure Fan Warning Fan Failure Memory Pre failure Memory Failure System Power Probe Warning System Power Probe Detects a Failure System Peak Power Power Supply Warning Power Supply Failure Degraded Redundancy Lost Redundancy Temperature Warning Temperature Failure Voltage Warning Voltage Failure Processor Warning Processor Failure Hardware Log Warning Hardware Log Full Watchdog Asr Storage System Warning Storage System Failure Storage Controller Warning Storage Controller Failure Physical Disk Warning Physical Disk Failure Virtual Disk Warning Virtual Disk Failure omreport Viewing System Status Using the Instrumentation Service 73 Enclosure Warning e Enclosure Failure e Storage Controller Battery Warning e Storage Controller Battery Failure e Removable Flash Media Present e Removable Flash Media Removed e Removable Flash Medi
208. omplete Syntax omconfig storage fluidcache action connect omconfig Partition Command The following sections provide the omconfig command syntax required to execute partition task Table 8 18 omconfig Partition Command Required Command Levels 1 2 3 Optional name value pairs omconfig storage partition action refresh omconfig Refreshing Partition List Use the following omconfig command syntax to refresh the partition list maintained in the storage subsytem Complete Syntax omconfig storage partition action refresh omconfig Fluid Cache Disk Command The following sections provide the omconfig command syntax required to execute the fluid cache disk task omconfig storage Commands 293 Table 8 19 omconfig Fluid Cache Disk Command Required Command Levels 1 2 3 Optional name value pairs omconfig storage fluidcachedisk action disablewithdiscard fluidcachedisk lt string gt omconfig Discarding Data and Disabling Caching Use the following omconfig command syntax to discard the data on the cache and disable caching on the specified fluid cache disk Complete Syntax omconfig storage fluidcachedisk action disablewithdiscard fluidcachedisk lt string gt Example Syntax omconfig storage fluidcachedisk action disablewithdiscard fluidcachedisk fcdl 294 omconfig storage Commands Working With CLI Command Results Server Administrator Command Line Interface CLI users can u
209. on controller Displays a list of the omreport storage controller parameters for displaying controller information enclosure Displays a list of the omreport storage enclosure parameters for displaying enclosure information omreport storage Commands 201 Table 7 1 Syntax for omreport storage help continued Command Command Command Level 3 Use Level 1 Level 2 battery globalinfo connector cachecade pciessed fluidcache fluidcachepool partition fluidcachedisk Displays a list of the omreport storage battery parameters for displaying battery information Displays a list of the omreport storage globalinfo parameters for displaying global storage property information Displays a list of the omreport storage connector parameters for displaying connector information Displays a list of the omreport storage cachecade parameters for displaying cachecade properties Displays the properties of the PCIe SSD subsystem Displays the fluid cache properties and the associated fluid cache disks Displays fluid cache pool properties Displays the partition details of the specified virtual disk Displays the fluid cache disk properties omreport Physical Disk Status Table 7 2 describes the syntax for the omreport physical disk commands 202 omreport storage Commands Table 7 2 omreport Physical Disk Commands Required Command Levels 1 2 3 and name value pair Optional name value
210. on when a power device probe detects that the power supply voltage regulator module or DC to DC converter has failed event processorwam Sets action or enables or disables alert generation when a processor probe detects that the processor is running at less than peak performance or speed event processorfail Sets action or enables or disables alert generation when a processor probe detects that the processor has failed event processorabsent Sets action or enables or disables alert generation when a processor probe detects that the processor is absent event redundegrad Sets action or enables or disables alert generation when the system fans and or power supplies become inoperative resulting in less than full redundancy for that component event redunlost Sets action or enables or disables alert generation when the system fans and or power supplies become inoperative resulting in a lost or a no redundant components working condition for that component event systempowerwarn Sets actions when a power consumption probe detects a warning value event systempowerfail Sets actions when a power consumption probe detects a failure value event tempwam Sets action or enables or disables alert generation when a temperature probe detects that the temperature is approaching the maximum or minimum limits event removableflashmediapresent Sets actions that Server Administrator
211. only when a custom profile is selected fanmode min max min Sets the mode to minimum power utilization max Sets the mode to maximum performance NOTE These options are applicable only when a custom profile is selected K NOTE Reboot the system for the power profiles setup options to take effect omconfig chassis pwrmonitoring or omconfig mainsystem pwrmonitoring Use the omconfig chassis pwrmonitoring or omconfig mainsystem pwrmonitoring command to configure power consumption information Table 4 11 lists the valid parameters for the command Table 4 11 Parameters of omconfig chassis pwrmonitoring or omconfig mainsystem pwrmonitoring name value pair 1 name value pair 2 Description index lt n gt NA Number of the probe or probe index must specify config probe warnthresh Sets the minimum and maximum settodefault warning thresholds values to default warmthresh lt n gt Sets a value for the warning threshold unit watt btuphr watt Displays the unit in Watts btuphr Displays the unit in BTU hr 134 omconfig Managing Components Using the Instrumentation Service Table 4 11 Parameters of omconfig chassis pwrmonitoring or omconfig mainsystem pwrmonitoring continued name value pair 1 name value pair 2 Description config resetreading type energy energy Resets the system energy reading peakpower peakpower Resets the system peak power K NOTE This command is applic
212. onsole redirection NOTE The attribute crab is valid only on Dell PowerEdge x9xx systems attribute cpucle setting enabled disabled enabled Enables processor C1 E after system reboot disabled Disables processor C1 E after system reboot attribute cpuht setting enabled disabled enabled Enables logical processor hyperthreading disabled Disables logical processor hyperthreading attribute cpuvt setting enabled disabled enabled Enables virtualization disabled Disables virtualization omconfig Managing Components Using the Instrumentation Service 103 104 Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems continued name value pair1 name value pair 2 attribute setting Description attribute cpuxdsupport setting enabled disabled enabled Enables Execute Disable XD support on the system disabled Disables XD support on the system attribute cpucore setting 1 2 4 6 8 10 12 fall 1 Enables one core per processor 2 Enables two cores per processor 4 Enables four cores per processor 6 Enables six cores per processor 8 Enables eight cores per processor 10 Enables ten cores per processor 12 Enables twelve cores per processor all Enables the maximum cores per processor attribute dbs setting enable disable enable Enables Demand Based Switching DBS on the system disable
213. onsole redirection failsafe baud rate to 115200 bits per second 106 omconfig Managing Components Using the Instrumentation Service Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems continued name value pair 1 attribute name value pair 2 setting Description attribute htassist setting enabled disabled enabled Enables the probe filter chipset option disabled Disables the probe filter chipset option NOTE Certain applications do not function fully if you enable or disable this option attribute ide setting on off force true on Enables IDE off Disables IDE force true Verification of setting change attribute setting off auto off Disables the device idepridry auto Detects and enables the device automatically attribute setting enabled enabled Enables the intrusion check intrusion disabled during system boot If the system also has bezel intrusion checking then the intrusion option checks for removal of the bezel of the system disabled Disables the intrusion check during system boot attribute setting enabled enabled Enables the internal USB port intusb 1 2 disabled disabled Disables the internal USB NOTE The port following option is deprecated attribute intusb attribute mouse setting on off on Enables the mouse off Disables the mouse omconfig Managing Components Using the Instrumentation
214. or omreport servermodule summary fmt tbl The example output displays as follows Network Interface 0 ATTRIBUTE VALUE IP Address 143 166 152 108 Subnet Mask 255 255 255 0 Default Gateway 143 166 152 1 MAC Address 00 02 b3 23 d2 ca Working With CLI Command Results Semicolon separated Values ssv Use the ssv formatting option to deliver output formatted in semicolon separated value format This format also allows you to import the command output results into a spreadsheet program such as Microsoft Excel or into a database program To see the following example command output in semicolon separated value format type omreport system summary fmt ssv or omreport servermodule summary fmt ssv The example output displays as follows Network Data Network Interface 0 IP Address 143 166 152 108 Subnet Mask 255 255 255 0 Default Gateway 143 166 152 1 AC Address 00 02 b3 23 d2 ca Custom Delimited Format cdv Use the cdv formatting option to report exported data in custom delimited format You can specify this option with any omreport command For example to generate a system summary in custom delimited format type omreport system summary fmt cdv or omreport servermodule summary fmt cdv You can also set preferences for the custom delimited format with the omconfig command The valid values for delimiters are exclamation semicolon at hash dollar percent caret
215. or Correction Type identifies the type of error checking and correction ECC that this memory can perform Examples are correctable ECC or uncorrectable ECC This report shows cache information for each cache present on the microprocessor omreport Viewing System Status Using the Instrumentation Service 61 omreport chassis pwrmanagement or omreport mainsystem pwrmanagement Use the omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command to view the power budget cap and power management profiles of the system The values display either in Watts or BTU Hr based on the configuration Type omreport chassis pwrmanagement or omreport mainsystem pwrmanagement K NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable K NOTE The omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command is applicable from PowerEdge yx x system onwards that support Power Management Bus PMBus and that have hot swappable power supplies and not systems that have a fixed non redundant power supply installed For each power management profile in the system values display for the following fields Maximum Performance Active Power Controller OS Control and Custom Custom attributes are CPU Power and Performance Management Memory Power and Performance Management and Fan Power and Performance Management 62 omreport Viewing S
216. or full redundancy Redundancy Mode Redundancy Input Source Line 1 upon Configuration redundancy restoration return to Line 1 AC Power Lines Status Ok Location AC Power Line 1 42 omreport Viewing System Status Using the Instrumentation Service AC Present Power Present Active Source Active Status gt Ok Location AC Power Line 2 AC Present Power Present Active Source Not Active Server Administrator reports values for the Redundancy Status and Redundancy Mode fields omreport chassis batteries or omreport mainsystem batteries Use the omreport chassis batteries or omreport mainsystem batteries command to view battery properties Type omreport chassis batteries or omreport mainsystem batteries Server Administrator displays the summary of the battery information for the system omreport chassis bios or omreport mainsystem bios Use the omreport chassis bios or omreport mainsystem bios command to view the current BIOS information Type omreport chassis bios or omreport mainsystem bios Server Administrator displays the summary of the BIOS information for the system omreport Viewing System Status Using the Instrumentation Service 43 omreport chassis biossetup or omreport mainsystem biossetup Use the omreport chassis biossetup or omreport mainsystem biossetup command to view BIOS setup parameters that are normally available only during system boot Type omreport chassis biossetup o
217. ormation Example Command for Adding Owner Information aaa a Contents Adding Service Contract Information 189 Example Command for Adding Service Information 02 190 Adding Support Information 190 Example Command for Adding Support Information 2 00 191 Adding System Information 192 Example Command for Adding System Information 200 193 Adding Warranty Information 193 Example Command for Adding Warranty Information 200 194 Using the Storage Management SEVICE aa mrii E BET ee area eae ae 197 CLI Command Syntax 197 Syntax for Required Optional and Variable Command Elements 198 User Privileges for omreport storage and omconfig storage 02 4 200 omreport storage Commands 201 omreport Physical Disk Status 202 omreport Virtual Disk Status 204 omreport Controller Status 205 omreport Enclosure Status 206 omreport Temperature Probe Status 207 Contents 10 omreportFan Status omreport Power Supply Status omreportEMM Status omreport Enclosure Slot Occupancy Report omreport Battery Status omreport Global Information Smart Thermal Shutdown Status Hot Spare Protection Policy
218. path to the escrow file gt Example Syntax To create the encryption key for the controller type omconfig storage controller action createsecuritykey controller 1 keyid Dell1_123 passphrase Dell_123 escrow yes filepath C escrow xml NOTE If you set escrow yes specify the escrow file path omconfig Change Encryption Key Use the following omconfig storage command syntax to change the encryption key for the controller if passphrase is provided omconfig storage Commands ___ 263 Complete Syntax omconfig storage controller action changesecuritykey controller id keyid lt keyid string gt passphrase lt passphrase string gt oldpassphrase lt old passphrase string gt escrow yes filepath lt Absolute path to the escrow file gt Example Syntax To change the encryption key for the controller type omconfig storage controller action changesecuritykey controller 1 keyid Dell_123 passphrase Dell_123 oldpassphrase Dell_321 escrow yes filepath C escrow xml K NOTE If you set escrow yes specify the escrow file path omconfig Delete Encryption Key Use the following omconfig command syntax to delete the encryption key for the controller Complete Syntax omconfig storage controller action deletesecuritykey controller id where id is the controller ID as reported by the omreport storage controller command Example Syntax To delete the security key on controller 1
219. perating system before shutting down the system false Does not close the file system or shut down the operating system before shutting down the system Example Shutdown Commands To set the shutdown action to reboot type omconfig system shutdown action reboot or omconfig servermodule shutdown action reboot omconfig Managing Components Using the Instrumentation Service 173 To bypass operating system shutdown before the system is powered off type omconfig system shutdown action reboot osfirst false Or omconfig servermodule shutdown action reboot osfirst false omconfig system thrmshutdown or omconfig servermodule thrmshutdown Use the omconfig system thrmshutdown or omconfig servermodule thrmshutdown command to configure a thermal shutdown action You can configure the system for a thermal shutdown when a temperature probe detects a temperature probe warning or failure event Table 4 32 lists the valid parameters for the command Table 4 32 Thermal Shutdown Parameters name value Description pair severity disabled Disable thermal shutdown An administrator must intervene disabled warning Perform a shutdown when a temperature warning event is Netter detected A warning event occurs when any temperature probe inside a ailure chassis reads a temperature in degree Celsius that exceeds the maximum temperature warning threshold value failure Perform a shutdown when a temperature failure event
220. probe warning threshold s set successfully K NOTE On PowerEdge x8xx systems you cannot set the minimum and maximum warning threshold values for the voltage omconfig preferences Use the omconfig preferences command to set system preferences Use the command line to set the SNMP root password and specify the user levels able to access Server Administrator You can also configure the Active Directory service and SNMP set operations omconfig preferences cdvformat Use the omconfig preferences cdvformat command to specify the delimiters for separating data fields reported in the custom delimited format The valid values for delimiters are exclamation semicolon at hash dollar percent caret asterisk tilde question colon comma and pipe omconfig Managing Components Using the Instrumentation Service 153 The following example shows how to set the delimiter for separating data fields to asterisk omconfig preferences cdvformat delimiter asterisk omconfig preferences dirservice Use the omconfig preferences dirservice command to configure the Active Directory service The lt productname gt oem ini file is modified to reflect these changes If the adproductname is not present in the lt productname gt oem ini file then a lt computername gt lt productname gt default value is used lt computername gt refers to the name of the computer running Server Administrator and lt productname gt refers to the name of the
221. r omreport mainsystem biossetup K NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable To view the BIOS Setup parameters in short form type omreport chassis biossetup display shortnames Table 3 3 lists the available BIOS setup parameters on systems prior to PowerEdge yx2x systems NOTE All the BIOS Setup parameters are not displayed Only those BIOS setup properties configured during system boot are displayed Table 3 3 BIOS Setup Parameters on Systems Prior to Dell PowerEdge yx2x System Parameters Description Bootsequence Displays the device used to boot the system Numlock Displays whether the keypad is used as number keys Embedded Video Displays whether the Embedded Video Controller option is Controller enabled or disabled Boot Mode Displays whether the boot mode is configured to BIOS or Unified Extensible Firmware Interface UEFT Processor C1 E Displays the Processor C1 E status CPU Execute Disable Displays whether the Execute Disable XD option is enabled or disabled Processor C State Displays whether the Processor C State Control option is Control enabled or disabled Processor CMP Displays the number of cores enabled per processor 44 l omreport Viewing System Status Using the Instrumentation Service Table 3 3 BIOS Setup Parameters on Systems Prior to Dell PowerEdge yx2x System cont
222. r omreport servermodule pedestinations The output of the omreport system pedestinations or omreport servermodule pedestinations command lists each of the valid parameters K NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable K NOTE The actual number of destinations you can configure on the system may differ Table 3 8 lists the available settings Table 3 8 Settings for the omreport system pedestinations or omreport servermodule pedestinations Output Attributes Description Destination List Destination Number destination 1 Displays the first Destination destination Example 101 102 103 104 IPv4 address of the first destination Destination Number destination 2 Displays the second Destination 2 destination Example 110 120 130 140 IPv4 address of the second destination Destination Number destination 3 Displays the third Destination 3 destination Example 201 202 203 204 IPv4 address of the third destination 78 omreport Viewing System Status Using the Instrumentation Service Table 3 8 Settings for the omreport system pedestinations or omreport servermodule pedestinations continued Output Attributes Description Destination Number Destination 4 Destination Number Destination 5 Destination Number Destination 6 Destination Number Destination 7 Destination Number
223. r 1 pdisk 0 2 3 K NOTE On a SAS controller the physical disk resides in enclosure 2 omconfig storage Commands 225 omconfig Cancel Rebuild Physical Disk Use the following omconfig command syntax to cancel a rebuild that is in progress If you cancel a rebuild the virtual disk remains in a degraded state See the Dell OpenManage Online Help for more information about Cancel Rebuild Physical Disk Complete Syntax omconfig storage pdisk action cancelrebuild controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To cancel the rebuild of the physical disk 3 on connector 0 of controller 1 e For SCSI SATA and ATA controllers omconfig storage pdisk action cancelrebuild controller 1 pdisk 0 3 e For SAS controllers omconfig storage pdisk action cancelrebuild controller 1 pdisk 0 2 3 K NOTE On a SAS controller the physical disk resides in enclosure 2 omconfig Cancel Replace Member Use the following omconfig command syntax to cancel a replace member operation Complete Syntax omconfig storage pdisk action cancelreplacemember controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID
224. r Administrator type omconfig about details true Server Administrator includes a number of services each having a version number of its own The Contains field reports version numbers for the services and provides other useful details The following is an example output of the omconfig about command The output may change depending on the configuration of the system and the version of Server Administrator Contains Broadcom SNMP Agent 10 xx xx Common Storage Module 3 x x Data Engine 5 x x Hardware Application Programming Interface 5 X X Instrumentation Service 6 x x Instrumentation Service Integration Layer Lxx Intel SNMP Agent 1 xx x OpenManage Inventory Collector 6 x x OpenManage Tools 6 x x Remote Access Controller 4 Data Populator 4A xX X Remote Access Controller 4 Managed Node 4 6 3 Secure Port Server 1 x x Server Administrator Framework 6 x x Agent for Remote Access 1 x x Storage Management 3 x x Sun Java Runtime Environment 1 x xx omconfig Managing Components Using the Instrumentation Service 99 omconfig chassis or omconfig mainsystem Use the omconfig chassis or omconfig mainsystem command to Set to default or assign specific values for fan voltage and temperature probes e Configure BIOS behavior during system start up e Clear memory error counts e Enable or disable power button control features if system configuration permits Use the omconfig chassis or omconfig mainsys
225. r50 r60 gt parameter required 256 omconfig storage Commands size lt number max min gt parameter required pdisk lt connector targetID connector targetID gt parameter required stripesize lt 2kb 4kb 8kb 16kb 32kb 64kb 128kb gt parameter optional cachepolicy lt d c gt parameter optional readpolicy lt ra nra ara rc nrc gt parameter optional writepolicy lt wb wt wc nwe fwb gt parameter optional name lt string gt parameter optional spanlength lt n gt parameter optional controller id Parameter Required Specify the controller ID as reported by the omreport storage controller command For example controller 2 raid lt e r0 r1 ric r5 r6 r10 r50 r60 gt Parameter Required Use the raid lt c 10 r1 rle 15 16 r10 150 160 gt parameter to specify concatenation or a RAID level for a virtual disk Different controllers support different RAID levels See the Dell OpenManage Online Help for more information about RAID levels a controller supports and for general information about RAID levels and concatenation Table 8 5 indicates how to specify the raid n parameter for each RAID level and concatenation Table 8 5 Raid Level and Concatenation RAID Level or Concatenation raid n Parameter Specification RAID 0 raid r0 RAID 1 raid rl RAID 5 raid r5 RAID 6 raid 16 RAID 10 raid rl0 RAID 50 r
226. rage vdisk action replacememberdisk controller 1 vdisk 4 source 0 3 destination 0 5 e For SAS controllers omconfig storage vdisk action replacememberdisk controller 1 vdisk 4 source 0 2 3 destination 0 52 55 K NOTE On a SAS controller the physical disk resides in enclosure 2 omconfig storage Commands 245 omconfig Rename Virtual Disk Use the following omconfig command syntax to rename a virtual disk Complete Syntax omconfig storage vdisk action rename controller id vdisk id name lt string gt where id is the controller ID and virtual disk ID as reported by the omreport command and lt string gt is the new name for the virtual disk To obtain the values for controller ID and virtual disk ID type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Example Syntax To rename virtual disk 4 on controller 1 to vd4 type omconfig storage vdisk action rename controller 1 vdisk 4 name vd4 246 omconfig storage Commands omconfig Enable Fluid Cache on Virtual Disk Use the following omconfig command syntax to enable fluid cache for the specified virtual disk K NOTE Enabling fluid cache creates a new fluid cache disk You must use only the new fluid cache disk for all future data access Data access to any of the corresponding virtual disk or caching its partitions may lead to dat
227. rcent using the available free space use RAID 5 and physical disks 0 through 3 on connector 0 of controller l For SAS controllers omconfig storage vdisk action reconfigure controller 1 vdisk 4 raid r5 pdisk 0 2 0 0 2 1 0 2 2 0 2 3 vdcapacityexpansion yes sizeinpercent 20 K NOTE vdcapacityexpansion parameter is supported only on PERC H700 and PERC H800 controllers If you set vdcapacityexpansion yes specify sizeinpercent If you do not set vdcapacityexpansion specify size K NOTE On a SAS controller the physical disk resides in enclosure 2 242 omconfig storage Commands omconfig Secure Virtual Disk Use the following omconfig command syntax to encrypt a virtual disk Complete Syntax omconfig storage vdisk action securevd controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Example Syntax To encrypt virtual disk 4 on controller 1 type omconfig storage vdisk action securevd controller 1 vdisk 4 omconfig Clear Virtual Disk Bad Blocks Use the following omconfig command syntax to clear virtual disk bad blocks Complete Syntax omconfig storage vdisk action clearvdbadblocks controller id vdisk id where id is the controller ID and virtual disk
228. re action disablealarm controller 1 enclosure 2 e For SAS controllers omconfig storage enclosure action disablealarm controller 1 enclosure 1 2 omconfig Set Enclosure Asset Tag Use the following omconfig command syntax to specify the enclosure s asset tag Complete Syntax omconfig storage enclosure action setassettag controller id enclosure lt ENCLOSUREID gt assettag lt string gt where id is the controller ID The lt ENCLOSUREID gt variable specifies the enclosure In this syntax lt string gt is a user specified alphanumeric string Example Syntax To specify the asset tag to encl20 on the enclosure attached to connector 2 on controller e For SCSI SATA and ATA controllers omconfig storage enclosure action setassettag controller 1 enclosure 2 assettag enc1l20 e For SAS controllers omconfig storage enclosure action setassettag controller 1 enclosure 1 2 assettag enc1l20 276 omconfig storage Commands omconfig Set Enclosure Asset Name Use the following omconfig command syntax to specify the asset name for an enclosure Complete Syntax omconfig storage enclosure action setassetnam controller id enclosure lt ENCLOSUREID gt assetname lt string gt where id is the controller ID The lt ENCLOSUREID gt variable specifies the enclosure In this syntax lt string gt is a user specified alphanumeric string Example Syntax To specify the asset name to
229. report chassis slots index n or omreport mainsystem slots index n The index parameter is optional If you do not specify the index Server Administrator displays properties for all of the slots in the system If you specify the index Server Administrator displays properties for a specific slot K NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable 68 omreport Viewing System Status Using the Instrumentation Service For each slot in the system values display for the following fields Index Slot ID Adapter and Data Bus Width Index is the number of the slot in the system Slot ID is the silk screen name printed on the system s motherboard next to the slot Alphanumeric text uniquely identifies each slot in the system Adapter refers to the name and or type of the card that fits into the slot for example a storage array controller SCSI adapter iDRAC Enterprise or HBA Data Bus Width is the width in bits of the information pathway between the components of a system The range of the data bus width is from 16 to 64 bits omreport chassis temps or omreport mainsystem temps Use the omreport chassis temps or omreport mainsystem temps command to view properties of the system s temperature probes Type omreport chassis temps index n or omreport mainsystem temps index n The index parameter is optional If you do not specify the ind
230. resides in enclosure 2 omconfig Disable Device Write Cache Use the following omconfig command to disable write cache on a physical disk for the PCIe SSD controller Complete Syntax omconfig storage pdisk action disabledevicewritecache controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To disable Write Cache on physical disk 3 on connector 0 of controller 1 e For SAS controllers omconfig storage pdisk action disabledevicewritecache controller 1 pdisk 0 2 3 NOTE On a SAS controller the physical disk resides in enclosure 2 omconfig Export Reliability Log Use the following omconfig command to export the log on a physical disk or the PCIe SSD controller omconfig storage Commands 229 Complete Syntax omconfig storage pdisk action exportlog controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To export
231. resides in enclosure 2 omconfig Initialize Physical Disk Use the following omconfig command syntax to initialize a physical disk Complete Syntax omconfig storage pdisk action initialize controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To initialize physical disk 4 on controller 1 type omconfig storage pdisk action initialize controller 1 pdisk 4 222 omconfig storage Commands omconfig Offline Physical Disk Use the following omconfig command syntax to make a physical disk offline Complete Syntax omconfig storage pdisk action offline controller id pdisk lt PDISKID gt where id is the controller ID The lt PDISKID gt variable specifies the physical disk To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller ID to display the IDs for the physical disks attached to the controller Example Syntax To make physical disk 3 on connector 0 of controller 1 offline e For SCSI SATA and ATA controllers omconfig storage pdisk action offline controller 1 pdisk 0 3 For SAS controllers omconfig storage pdisk action offline controller 1 pdisk 0
232. ritepolicy lt wb wt we nwe fwb gt parameter optional e cachepolicy lt d c gt parameter optional diskcachepolicy lt enabled disabled gt parameter optional Example Syntax To change the read policy of virtual disk on controller 1 to no read ahead type omconfig storage vdisk action changepolicy controller 1 vdisk 4 readpolicy nra 244 omconfig storage Commands omconfig Replace Member Virtual Disk Use the following omconfig command syntax to replace the member of a given virtual disk with the destination disk Complete Syntax omconfig storage vdisk action replacememberdisk controller id vdisk id source lt PDISKID gt destination lt PDISKID gt where id is the controller ID and virtual disk ID The lt PDISKID gt variable specifies the physical disk To obtain the values for the controller virtual disk and physical disk type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID and omreport storage pdisk controller ID to display the IDs for the virtual disks and physical disks attached to the controller Example Syntax In this example you are replacing physical disk 3 on connector 0 of controller 1 of virtual disk 4 with physical disk 5 On a Serial Attached SCSI SAS controller the physical disk resides in enclosure 2 To replace the member disk described in this example e For SCSI SATA and ATA controllers omconfig sto
233. rmonitoring command is applicable from PowerEdge yx0x system onwards that support PMBus and that have hot swappable power supplies and not systems that have a fixed non redundant power supply installed NOTE Power monitoring requires license to report the details If the appropriate license is not installed or has expired the system does not display the power consumption details of the system For more information see 7he Dell Licensing Management Guide at dell com support manuals NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable Table 3 5 omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring name value pair Description config stats Reports power statistics in Watts omreport Viewing System Status Using the Instrumentation Service 64 The following is an example output Power Consumption Information Power Consumption Index Status Probe Name Reading Warning Threshold Failure Threshold Amperage PS1 Current 1 Power Headroom System Instantaneous Headroom System Peak Headroom omreport Viewing System Status Using the Instrumentation Service 1 Ok System Board Pwr Consumption 539W 994W 1400 W 300 W 340 65 Power Tracking Statistics 66 Statistic Measurement Start Time Measurement Finish Time Reading Statistics Measurement Start Time Peak Time Peak Re
234. robe omreport chassis firmware or omreport mainsystem firmware Use the omreport chassis firmware or omreport mainsystem firmware command to view current firmware properties When you type omreport chassis firmware or omreport mainsystem firmware 50 omreport Viewing System Status Using the Instrumentation Service Server Administrator displays a summary of the system s firmware properties K NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable K NOTE If iDRAC is installed Server Administrator displays the Life Cycle Controller LCC version If BMC is installed Server Administrator displays the Unified Server Configurator USC version omreport chassis frontpanel or omreport mainsystem frontpanel Use the omreport chassis frontpanel or omreport mainsystem frontpanel command to view if the front panel button control settings such as the Power button and or Nonmasking Interrupt NMI button if present on the system are enabled or disabled If the Power button override is present on the system check whether the Power button override is enabled or not If enabled the Power button turns the power to the system On and Off If the NMI button is present on the system check whether the NMI button is enabled or not Use the NMI button to troubleshoot software and device errors when using certain operating systems The Front Panel LCD
235. roller Example Syntax To cancel a check consistency on virtual disk 4 on controller 1 type omconfig storage vdisk action cancelcheckconsistency controller 1 vdisk 4 omconfig Pause Check Consistency Use the following omconfig command syntax to pause a check consistency while it is in progress See the Dell OpenManage Online Help for more information about Pause Check Consistency Complete Syntax omconfig storage vdisk action pausecheckconsistency controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller Ds and then type omreport storage vdisk controller ID to display the IDs for the virtual disks attached to the controller Example Syntax To pause a check consistency on virtual disk 4 on controller 1 type omconfig storage vdisk action pausecheckconsistency controller 1 vdisk 4 234 omconfig storage Commands omconfig Resume Check Consistency Use the following omconfig command syntax to resume a check consistency after it has been paused Complete Syntax omconfig storage vdisk action resumecheckconsistency controller id vdisk id where id is the controller ID and virtual disk ID as reported by the omreport command To obtain these values type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller ID to display the IDs for t
236. rtH setting Off Auto attribute setting lt string gt SataPortHCapacity attribute setting lt string gt SataPortHDriveType 120 omconfig Managing Components Using the Instrumentation Service Table 4 4 BIOS Setup Settings on PowerEdge yx2x Systems continued Group name value pair 1 name value pair 2 attribute setting SATA Settings attribute SataPortHModel setting lt string gt continued Serial attribute ConTermType _ setting Vt100Vt220 Ansi Communication attribute ExtSerialConnector attribute FailSafeBaud attribute RedirAfterBoot attribute SerialComm attribute SerialPortAddress setting Seriall Serial2 RemoteAccDevice setting 115200 57600 19200 9600 setting Enabled Disabled setting OnNoConRedir OnConRedirCom OnConRedirCom2 Off setting SeriallCom1 Serial2Com2 Seriall Com2Serial2Com1 Com Com2 Slot Disablement omconfig Managing Components Using the Instrumentation Service attribute Slotl attribute Slot2 attribute Slot3 attribute Slot4 attribute Slot5 attribute Slot6 attribute Slot7 setting Enabled Disabled BootDriverDisabled setting Enabled Disabled BootDriverDisabled setting Enabled Disabled BootDriverDisabled setting Enabled Disabled BootDriverDisabled setting Enabled Disabled BootDriverDisabled setting Enabled Disabled BootDriverDisabled setting Enabled Disabled BootDriverDisabled
237. rtrecoverforeignconfig controller 1 omconfig Clear Foreign Configuration Use the following omconfig command syntax to clear or delete all virtual disks that reside on physical disks newly attached to the controller Complete Syntax omconfig storage controller action clearforeignconfig controller id where id is the controller ID as reported by the omreport storage controller command 268 omconfig storage Commands Example Syntax To clear foreign configurations on controller 1 type omconfig storage controller action clearforeignconfig controller 1 omconfig Physical Disk Power Management Use the following omconfig command syntax for managing the power of physical disks in a controller by spinning down hot spares configured drives and unconfigured drives Complete Syntax omconfig storage controller action setpdiskpwrmanagement spindownunconfigureddrives lt enabled disabled gt spindownhotspares lt enabled disabled gt spindownconfigureddrives lt enabled disabled gt idlec lt enabled disabled gt spindowntimeinterval lt 30 to 1440 gt minutes spinupstarttime lt HH MM AM PM gt spinuptimeinterval lt 1 to 24 gt hours where id is the controller ID as reported by the omreport storage controller command K NOTE On PERC 7 controllers only spindownunconfigureddrives spindownhotspares and spindowntimeinterval parameters are supported K NOTE You can specify spinupstarttime and spinuptimein
238. s documented in this chapter vary in whether they define the fields that appear in the results of a particular omreport command The fields are defined only if they have a special or less familiar use As with all other components use omreport to view component status and omconfig to manage a component For information on configuring components for management see omconfig Managing Components Using the Instrumentation Service on page 91 Use the omreport commands to get information you need to execute an omconfig command For example to edit the minimum temperature for a warning event on a temperature probe you must know the index of the probe you want to configure Use omreport chassis temps to display a list of probes and their indexes The omreport commands available on the system depend on the system configuration Table 3 1 lists the systems on which the omreport commands are applicable Table 3 1 System Availability for the omreport Command Command Level1 Command Level 2 Applicable To omreport modularenclosure Blade systems servermodule Blade systems mainsystem Blade systems system Rack and Tower systems chassis Rack and Tower systems preferences Blade or Rack and Tower systems omreport Viewing System Status Using the Instrumentation Service 31 Conventions for Parameter Tables When listing the parameters for a command the parameters are listed in alphabetical order instead of the order in which they appear
239. s processors 59 cancel background initialize omconfig 239 cancel check consistency omconfig 233 cancel clear physical disk omconfig 227 231 cancel initialize disk omconfig 238 cancel rebuild physical disk omconfig 226 cdvformat omconfig preferences 153 change virtual disk policy omconfig 244 chassis omconfig 100 304 Index chassis fault LED 129 chassis identification LED 129 chassis information summary 52 check consistency omconfig 233 check consistency rate omconfig 265 clear foreign configuration omconfig 268 clear physical disk omconfig 227 CLI clearing logs 163 error messages error checking 21 CLI command levels 1 2 and 3 defined 28 CLI command output 295 appending command output to a file 297 controlling display 295 formatting output 299 saving to a file that can be overwritten 296 table format 300 writing to a file 296 CLI commands 27 primary commands 19 cmdlog omcontig system 163 omreport system 7 1 command levels 1 2 and 3 omcontig 93 command levels 1 2 3 omreport 33 command syntax overview 24 commands for clearing logs 163 commands for viewing logs 71 components alert actions 159 events 74 75 failure messages 22 instrumentation service 91 omreport 31 32 omreport system 70 omreport system summary 38 omreport system version 38 SNMP traps 168 storage 201 217 summary 80 updating 20 warning and
240. s the system boot settings when bootmode is set to bios Embedded Server Sets up the Embedded Server Management options Management Integrated Devices Controls the devices integrated on the system board Memory Settings Controls the system memory settings Miscellaneous Settings Controls some miscellaneous system settings One Time Boot Supports one time boot to a specified device Processor Settings Controls the processor s settings of the system SATA Settings Control the embedded SATA ports settings Serial Communication Controls the Serial Communication options Slot Disablement Controls the system slots that are present on the system System Information Displays the information that uniquely identifies the system System Profile Settings Controls the power management settings System Security Controls the security features of the system UEFI Boot Settings Controls the system boot settings when boot mode is set to uefi omreport chassis currents or omreport mainsystem currents This command is no longer available through Server Administrator 48 omreport Viewing System Status Using the Instrumentation Service omreport chassis removableflashmedia or omreport mainsystem removableflashmedia Use the omreport chassis removableflashmedia or omreport mainsystem removableflashmedia to view the removable flash media details on the system along with its health status Type omreport ch
241. script so that the system shuts down to prevent damage The administrator could then distribute and execute the script to many managed systems at the same time Such a scenario facilitates configuring any number of new systems acquired by a company and makes implementation of new system administration policies easier across many existing systems that require reconfiguration A similar scenario is used to populate a large number of newly acquired systems with detailed asset information Much of the information are the same such as the manufacturer or lessor of the system whether support for the system is outsourced name of the company providing insurance for the system method of depreciation and so on Any variable that is common to all systems is scripted sent to all managed systems and executed Asset information that is unique to a system is scripted as a group and sent to that managed node for execution For example a script could specify values for all unique variables such as the owner primary user phone number asset tag and so on Scripts to populate unique values would set all unique variables at once rather than one by one through the system s command line In many cases the CLI allows a user with a very well defined task in mind to retrieve information about the system rapidly If a user wants to review a comprehensive summary of all system components and save that summary information to a file for comparison with later system stat
242. se the command output in various ways This section explains how to save command output to a file and how to select a format for the command results that fits different objectives Table 9 1 System Availability for the omreport Command Command Level 1 Command Level 2 Applicable To omreport modularenclosure Blade systems servermodule Blade systems mainsystem Blade systems system Rack and Tower systems chassis Rack and Tower systems Output Options for Command Results CLI command output displays to standard output on the system in a command window in an X terminal or on a screen depending on the type of the operating system You can redirect command results to a file instead of displaying them to standard output Saving command output to a file allows you to use the command output for later analysis or comparison Whether you display command results to standard output or have the command results written to a file you can format the results The format you select determines the way the command output is displayed and the way the command output is written to a file Controlling Command Output Display Each operating system provides a means of controlling the way that command results display to standard output The following is a useful command for ensuring that command results do not scroll by before you can view them The same command syntax works for the Microsoft Windows command prompt the Red Hat Enterprise Linux termina
243. state 59 omreport chassis slots adapter 69 data bus width 69 index 69 slot ID 69 omreport modularchassis 39 omreport preferences commands 90 omreport preferences webserver 90 omreport storage battery 211 213 controller 205 enclosure 206 211 globalinfo 212 pdisk 203 vdisk 204 214 216 omreport system alertaction 72 alertlog 71 assetinfo 74 cmdlog 71 312 Index esmlog 71 events 74 operatingsystem 77 pedestinations 77 platformevents 80 recovery 80 shutdown 80 summary 80 thrmshutdown 88 version 88 omreport system assetinfo 74 omreport system commands 70 omreport system events name value pairs 76 omrpeort system components 70 online physical disk omconfig 223 operating system omreport system 77 outsource information 186 Overall 72 overall health status of the ESM log 72 owner information 188 P parameters for fan warning thresholds 124 pause check consistency omcontig 234 pdisk 218 omcontig storage 197 198 omconfig virtual disk 256 257 omreport physical disk 203 omreport storage 203 pedestinations omconfig system 164 omreport system 77 Physical disks in each stripe 260 platformevents omconfig system 164 omreport system 80 port type omreport chassis ports 58 ports omreport chassis 57 prepare to remove physical disk 221 primary CLI command omcontig 19 omhelp 19 27 omreport 19 primary CLI commands 19 pr
244. storage Displays all batteries present battery on all controllers on the system some controllers do not have batteries controller id Displays the battery on the where id is the controller number specified controller For example controller 0 controller id battery id Displays the specified battery where id is the controller number For example controller 0 omreport storage Commands 211 omreport Global Information Smart Thermal Shutdown Status Hot Spare Protection Policy Table 7 12 describes the syntax for the omreport global information command Table 7 12 omreport Global Information Commands Required Command Optional name Use Levels 1 2 3 value pairs omreport storage Displays whether smart thermal shutdown is globalinfo enabled or disabled For more information see the omcontig Global Enable Smart Thermal Shutdown on page 283 Displays the hot spare protection policy that you have set For more information see the Dell OpenManage Server Administrator Storage Management User s Guide at dell com support manuals 212 omreport storage Commands omreport Connector Status Table 7 13 describes the syntax for the omreport connector commands Table 7 13 omreport Connector Commands Required Command Optional name Use Levels 1 2 3 value pairs omreport Displays all connectors present on all controllers storage on the system connector controller id where i
245. strator The omconfig preferences useraccess command allows you to grant or withhold the right of users and power users to access Server Administrator Table 4 20 lists the valid parameters for the command Table 4 20 Enabling User Access for Administrators Power Users and Users Command Result Description omconfig preferences useraccess Grants Server Least restrictive form of enable user Administrator access user access to Users Power Users and Administrators omconfig preferences useraccess Grants Server Excludes user level enable poweruser Administrator access access only to Power Users and Administrators omconfig preferences useraccess Grants Server Most restrictive form of enable admin Administrator access user access to Administrators only 156 omconfig Managing Components Using the Instrumentation Service omconfig preferences webserver Use the omconfig preferences webserver command to set the encryption levels of the Server Administrator Web server and configure the URL launch point in the Server Administrator Web server environment Table 4 21 lists the parameters you can use with this command Table 4 21 Configuring Webserver Preferences name value pair 1 name value pair 2 Description attribute setting autonegotiate autonegotiate Sets the encryption sslencryption 128bitorhigher levels automatically based on your web browser settings 128bitorhigher Sets the encryption lev
246. sumecheckconsistency controller id vdisk id action blink controller id vdisk id action unblink controller id vdisk id action initialize controller id vdisk id action fastinit controller id vdisk id force yes action slowinit controller id vdisk id force yes action cancelinitialize controller id vdisk id action cancelbginitialize controller id vdisk id action assigndedicatedhotspare controller id vdisk id pdisk lt PDISKID gt assign lt yes no gt action deletevdisk controller id vdisk id force yes action format controller id vdisk id action reconfigure controller id vdisk id raid lt c r0 rl rle r5 rl0 gt pdisk lt PDISKID gt size lt size gt vdcapacityexpansion yes sizeinpercent lt 1 to 100 gt action securevd controller id vdisk id action clearvdbadblocks controller id vdisk id action changepolicy controller id vdisk id readpolicy lt ra nra ara rc nrc gt writepolicy lt wb wt we nwe fwb gt cachepolicy lt d c gt diskcachepolicy lt enabled disabled gt 232 omconfig storage Commands Table 8 3 omconfig Manage Virtual Disk Commands continued Required Optional name value pairs Command Levels 1 2 3 omconfig action replacememberdisk controller id vdisk id source storage vdisk lt PDISKID gt destination lt PDISKID gt continued action rename controller id vdisk id action enablefluidcache controller id vdisk id devicename lt string gt
247. system or servermodule assetinfo info outsource levels lt n gt Levels of service that the provider offers problemcomponent System component lt component gt that requires maintenance providerfee Amount of money lt providerfee gt charged for maintenance servicefee Amount of money lt servicefee gt charged for service signauth lt name gt Person who signed or authorized the service 186 omconfig system or servermodule assetinfo Editing Cost of Ownership Values Example Command for Adding Outsource Information To provide a value for an outsource parameter type a command of the form omconfig system assetinfo info outsource lt name value pair 2 gt or omconfig servermodule assetinfo info outsource lt name value pair 2 gt For example type omconfig system assetinfo info outsource providerfee 75 Or omconfig servermodule assetinfo info outsource providerfee 75 The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all the parameters for name value pair 2 belong to name value pair 1 For an example see Example Commands for Adding Acquisition Information on page 179 omconfig system or servermodule assetinfo Editing Cost of Ownership Values 187 Adding Owner Information The owner is the party that holds legal property title to the system Tabl
248. system owner purchase price details of any lease that is in effect depreciation methods and rates and location of the system warranty and extended warranty duration outsourcing details and service level agreement User Level Required for Adding Asset Information Power Users and Administrators can add and edit asset information Table 5 1 System Availability for the omconfig Command Command Level 1 Command Level 2 Applicable to omconfig servermodule Blade systems mainsystem Blade systems system Rack and Tower systems chassis Rack and Tower systems Adding Acquisition Information Acquisition refers to the facts about a business entity s purchase or lease of a system Use the omconfig system assetinfo info acquisition or omconfig servermodule assetinfo info acquisition command to add detailed information about the purchase or lease of a system Table 5 2 lists the valid parameters for the command omconfig system or servermodule assetinfo Editing Cost of Ownership Values 177 Table 5 2 Parameters of omconfig system assetinfo info acquisition or omconfig servermodule assetinfo info acquisition Command Command Command Name Name Value Description Level 1 Level 2 Level3 Value Pair1 Pair2 omconfig system or servermodule assetinfo info acquisition costcenter The name or code for lt text gt the business entity that acquired the system expensed yes Whether the system is no charged to a specific p
249. t and the global event alert are enabled event batterywarn Sets action or enables or disables alert generation when a battery device detects that the battery is pending a failure condition event batteryfail Sets action or enables or disables alert generation when a battery device detects that the battery has failed event discretevolt Sets action or enables or disables alert generation when a discrete voltage probe detects that the voltage is too low for proper operation event fanfail Sets action or enables or disables alert generation when a fan probe detects that the fan is running too slow or not running event hardwarelogfail Enables or disables alert generation when a hardware log detects a failure value event intrusion Sets action or enables or disables alert generation when a chassis is opened event powerwarn Sets action or enables or disables alert generation when a power device probe detects that the power supply voltage regulator module or DC to DC converter is pending a failure condition event powerabsent Sets action or enables or disables alert generation when a processor probe detects that the power supply is absent 166 omconfig Managing Components Using the Instrumentation Service Table 4 26 Parameters of omconfig system platformevents continued Event Name Description event powerfail Sets action or enables or disables alert generati
250. t information adding 190 syntax overview CLI commands 24 system 177 system information adding 192 T table format for CLI command output 300 temperature probe warning threshold 151 temps omcontig chassis 150 omreport chassis 69 thermal shutdown about 88 configuring 174 example commands 175 thrmshutdown omcontig system 174 omreport system 88 U unblink physical disk omcontig 220 user access to Server WwW Administrator warranty adding 193 components 181 193 administrators only 156 determining 156 least restrictive 156 most restrictive 156 smeonhe systemu 19g power users and administrators webserver only 156 omconfig system 171 ds radces starting and stopping 171 omconfig preferences 156 what s new 18 write policy parameters 260 V vdisk omconfig storage 232 233 omreport storage 204 214 216 version omreport system 88 viewing alert actions for specific components and events 72 viewing properties for system temperature probes 69 viewing properties for system voltage probes 69 viewing properties of system power supplies 67 viewing properties of system slots 68 voltage warning thresholds 152 volts omconfig chassis 152 omreport chassis 69 Index 315 Index 316
251. t status of the processor Connector Name is the name or number of the device that occupies the processor slot in the system Processor Brand is the type of processor made by a manufacturer such as Intel Itanium Intel Pentium HI Intel Xeon or AMD Opteron Processor Version is the model and stepping number of the processor 58 omreport Viewing System Status Using the Instrumentation Service Current Speed is the actual processor speed in MegaHertz at system boot time State is whether the processor slot is enabled or disabled Core Count is the number of processors integrated into one chip Capabilities and Cache Properties of a Specific Processor To view the cache properties of a processor on a given connector type omreport chassis processors index n or omreport mainsystem processors index n The index parameter is optional If you do not specify the index Server Administrator displays properties for all processors If you specify the index Server Administrator displays properties for a specific processor The following fields are defined for the capabilities present on a particular microprocessor For Intel Processor e 64 bit Support e Hyperthreading HT e Virtualization Technology VT e Demand Based Switching DBS e Execute Disable XD e Turbo Mode For AMD Processor e 64 bit Support e AMD V e AMD PowerNow e No Execute NX omreport Viewing System Status Using the Instrumentation Service 59
252. tem command to view a list of all omconfig chassis or omconfig mainsystem commands omconfig chassis biossetup or omconfig mainsystem biossetup Use the omconfig chassis biossetup or omconfig mainsystem biossetup command to configure system BIOS settings that are normally available only in the BIOS setup boot time settings of the system A CAUTION Changing certain BIOS setup options may disable the system or require you to reinstall the operating system NOTE Reboot the system for the BIOS setup options to take effect K NOTE Not all BIOS setup options are available on every system NOTE Due to the limitations of certain operating systems for example VMware ESXi certain features are not available with this release of OpenManage Server Administrator NOTE When CSIOR Collect System Inventory on Restart is disabled you cannot configure the BIOS settings using omconfig command 100 l omconfig Managing Components Using the Instrumentation Service Table 4 3 lists the name value pairs you can use with this command on systems prior to PowerEdge yx2x systems Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems name value pair1 name value pair 2 attribute setting Description attribute acpwrrecovery delay random immediate timedelay time lt value gt setting off last on off System is turned off last System returns to the previous state on System is turne
253. tem Board Fan 1 RPM Reading 2380RPM Minimum Warning Threshold 600RPM Maximum Warning Threshold 5700RPM Minimum Failure Threshold 500RPM Maximum Failure Threshold 6000RPM Four hours later you repeat the command You have no interest in the 11 00 A M snapshot as written to fans txt You type the same command omreport chassis fans index 0 outc fans txt or omreport mainsystem fans index 0 outc fans txt The 3 00 PM data overwrites the 11 00 A M data in the fans txt file Fans txt now reads as follows Index 0 Status OK Probe Name System Board Fan 1 RPM Reading 3001RPM Minimum Warning Threshold 7OORPM Maximum Warning Threshold 5500RPM Minimum Failure Threshold 500RPM Maximum Failure Threshold 6000RPM You cannot refer to the previous command results to compare the earlier fan probe 0 output with the present output because in using the outc option you overwrote the fans txt file Append Command Results to an Existing File Use the outa option when you want to append new command results to data stored in a previously written file For example at 11 00 A M you capture fan probe RPM readings for fan probe 0 on the system and write the results to a Working With CLI Command Results 297 file called fans txt To compare these results with output for the same probe obtained four hours later you can use the outa command to append the new output to fans txt Type omreport chassis fans
254. terval only when you set spindownconfigureddrives enabled Example Syntax To spin down drives that are not configured or hot spares that are unattended for 30 minutes type omconfig storage controller action setpdiskpwrmanagement spindownunconfigureddrives enabled spindownhotspares enabled spindowntimeinterval 30 controller 1 omconfig storage Commands 269 omconfig Set Patrol Read Mode Use the following omconfig command syntax to set the patrol read mode for the controller Complete Syntax omconfig storage controller action setpatrolreadmode controller id mode manual auto disable where id is the controller ID as reported by the omreport storage controller command Example Syntax To set the patrol read on controller 1 to manual mode type omconfig storage controller action setpatrolreadmode controller 1 mode manual omconfig Start Patrol Read Use the following omconfig command syntax to start the patrol read task on the controller Complete Syntax omconfig storage controller action startpatrolread controller id where id is the controller ID as reported by the omreport storage controller command Example Syntax To start the patrol read task on controller 1 type omconfig storage controller action startpatrolread controller 1 K NOTE To start patrol read the current patrol read mode is set to Manual 270 omconfig storage Commands omconfig Stop Patrol Read Use the following omconf
255. the Dell OpenManage Server Administrator Storage Management User s Guide Complete Syntax For dedicated hot spare protection policy type omconfig storage globalinfo action setprotectionpolicies type dhs raid lt rl r5 r6 r10 r50 r60 all gt hscount lt 1 16 gt warnlevel lt 0 3 gt where hscount is the number of hot spares assigned to the virtual disk and warnlevel is the severity level you want to assign to the generated alert if this policy is violated Use hscount 0 warnlevel 0 to reset the dedicated hot spare protection policy for the RAID level omconfig storage Commands 285 For global hot spare protection policy type omconfig storage globalinfo action setprotectionpolicies type ghs hscount lt 1 16 gt warnlevel lt 0 3 gt includeghsinvdstate lt yes no gt where hscount is the number of hot spares assigned to the virtual disk and warnlevel is the severity level you want to assign to the generated alert if this policy is violated Use hscount 0 warnlevel 0 to reset the global hot spare protection policy for the RAID level omconfig Connector Commands The following sections provide the omconfig command syntax required to execute connector tasks Table 8 14 omconfig Connector Commands Required Command Levels 1 2 3 Optional name value pairs omconfig storage connector action rescan controller id connector id omconfig Rescan Connector Use the following omconfig comm
256. tor installed on the system Contains Instrumentation Service 7 x x Storage Management 4 x x Sun Java Runtime Environment 1 x x_xx Secure Port Server 7 x x Server Administrator Core Files 7 x x Instrumentation Service Integration Layer Wades SE Server Administrator Common Framework 7 x x Common Storage Module 4 x x Data Engine 7 x x Instrumentation Service 7 x x omreport chassis or omreport mainsystem Commands Use the omreport chassis or omreport mainsystem commands to view details for the entire chassis or for a particular component omreport chassis or omreport mainsystem Type omreport chassis Or omreport mainsystem omreport Viewing System Status Using the Instrumentation Service 41 Server Administrator displays a general status for the main system chassis or main system components Health Main System Chassis SEVERITY COMPONENT Ok Fans Critical Intrusion Ok Memory Ok Power Supplies Ok Temperatures Ok Voltages omreport chassis acswitch or omreport mainsystem acswitch Use the omreport chassis acswitch or omreport mainsystem acswitch command if the system has redundant AC power lines that are configured in a failover arrangement Type omreport chassis acswitch or omreport mainsystem acswitch Server Administrator displays the following output AC Failover Switch AC Switch Redundancy Redundancy Status Full Number of devices a2 required f
257. troller Use the following omconfig command syntax to rescan a controller For more information see the Dell OpenManage Online Help Complete Syntax omconfig storage controller action rescan controller id where id is the controller ID as reported by the omreport storage controller command Example Syntax To rescan controller 1 type omconfig storage controller action rescan controller 1 K NOTE The rescan controller is not supported on non RAID SCSI and SAS controllers Reboot the system to make the configuration changes visible on non RAID SCSI controllers omconfig Enable Controller Alarm Use the following omconfig command syntax to enable the controller alarm See the Dell OpenManage Online Help for more information about Enable Controller Alarm 252 omconfig storage Commands Complete Syntax omconfig storage controller action enablealarm controller id where id is the controller ID as reported by the omreport storage controller command Example Syntax To enable the alarm on controller 1 type omconfig storage controller action enablealarm controller 1 omconfig Disable Controller Alarm Use the following omconfig command syntax to disable the controller alarm See the Dell OpenManage Online Help for more information about Disable Controller Alarm Complete Syntax omconfig storage controller action disablealarm controller id where id is the controller ID as reported by the omreport storage co
258. ts are unique and may not resemble the hardware and software configuration of the system System Summary Software Profile Systems Management Name Version Description Contains Dell OpenManage Server Administrator 2 X X X Systems Management Software Common Storage Module 4 x x Data Engine 7 x x Hardware Application Programming Interface 7 x x Instrumentation Service 7 x x Instrumentation Service Integration Layer 7 0 0 OpenManage Inventory Collector TERR Remote Access Controller Data Populator 7 x x Remote Access Controller Managed Node 7 x x Secure Port Server 7 x x Server Administrator Common Framework 7 x xX omreport Viewing System Status Using the Instrumentation Service 81 Operating System Name Version System Time System Bootup Time System Host Name System Location Life Cycle Controller Main System Chassis Chassis Information Chassis Model Chassis Service Tag Pleas Tiy Sun Java Runtime LERI R2 Server Administrator Core files Storage Management 4 x x Environment Microsoft Windows Server 2008 Enterprise x64 Edition Version 6 1 lt Build 7600 gt lt x64 gt Server Full Installation Fri May 20 18 02 Wed May 18 18 37 WIN 27C02UQFV6L set th 52 2XXX 58 2XXX valu N A PowerEdge R720 gt 7654321 omreport Viewing
259. tting Off Auto setting lt string gt setting lt string gt setting lt string gt setting Off Auto setting lt string gt setting lt string gt setting lt string gt setting Off Auto setting lt string gt setting lt string gt setting lt string gt setting Off Auto setting lt string gt setting lt string gt attribute SataPortCModel setting lt string gt omconfig Managing Components Using the Instrumentation Service 119 Table 4 4 BIOS Setup Settings on PowerEdge yx2x Systems continued Group name value pair 1 name value pair 2 attribute setting SATA Settings attribute SataPortD setting Off Auto continued attribute setting lt string gt SataPortDCapacity attribute setting lt string gt SataPortDDriveType attribute SataPortDModel setting lt string gt attribute SataPortE setting Off Auto attribute setting lt string gt SataPortECapacity attribute setting lt string gt SataPortEDrive Type attribute SataPortEModel setting lt string gt attribute SataPortF setting Off Auto attribute setting lt string gt SataPortF Capacity attribute setting lt string gt SataPortFDriveType attribute SataPortFModel setting lt string gt attribute SataPortG setting Off Auto attribute setting lt string gt SataPortGCapacity attribute setting lt string gt SataPortGDriveType attribute SataPortGModel setting lt string gt attribute SataPo
260. tware and storage Displays how to perform the shutdown action if any when a temperature warning or failure condition is detected Displays a summary for all updatable components on the system Displays the URL information of the Server Administrator Web server 33 omreport Viewing System Status Using the Instrumentation Service Help With the omreport Command Use the omreport command to get a list of the available commands for omreport Use omreport lt command level 2 gt to get help on the level 2 about chassis and system commands The following information on omreport system also applies to get help for the omreport chassis command To see a list of valid commands for omreport system type omreport system more omreport modularenclosure Use the omreport modularenclosure command to view details of the Blade system Type omreport modularenclosure K NOTE This CLI command is available when Dell OpenManage Server Administrator is installed on Dell Blade systems Server Administrator displays information related to the modular enclosure and chassis management controller CMC if available K NOTE The output varies depending on the configuration of the system Modular Chassis Information Chassis Information Attribute Model Value Modular Server Enclosure Attribute Lock Value true Attribute Service Tag Value 8RLNB1S Attribute Express
261. u are also selecting the default value for the maximum warning threshold value Specifying a Value for Minimum and Maximum Warning Thresholds If you prefer to specify values for the fan probe warning thresholds you must specify the number of the probe you are configuring and the minimum and or maximum warning threshold values In the following example the probe that is being configured is probe 0 The first command sets only the minimum threshold the second sets the minimum and maximum thresholds omconfig chassis fans index 0 minwarnthresh 4580 or omconfig mainsystem fans index 0 minwarnthresh 4580 omconfig chassis fans index 0 minwarnthresh 4580 maxwarnthresh 9160 or omconfig mainsystem fans index 0 minwarnthresh 4580 maxwarnthresh 9160 omconfig Managing Components Using the Instrumentation Service 125 When you issue the command and the system sets the values you specify the following message is displayed Fan probe warning threshold s set successfully K NOTE You cannot set the minimum and maximum warning thresholds for the fan probe on PowerEdge x8xx and x9xx systems omconfig chassis frontpanel or omconfig mainsystem frontpanel Use the omconfig chassis frontpanel or omconfig mainsystem frontpanel command to e configure the power button and the Nonmasking Interrupt NMI button e configure the LCD to display No information Custom information Default system information Service tag system name
262. ue pair 2 setting Description attribute romb setting raid off scsi force true raid Instructs the BIOS to detect RAID on motherboard as a RAID device off Disables RAID on motherboard during system boot scsi Instructs the BIOS to detect the RAID on motherboard device as a SCSI device force true Verification of setting change attribute romba setting raid scsi force true raid Instructs the BIOS to detect RAID on motherboard channel A as a RAID device scsi Instructs the BIOS to detect the RAID on motherboard device as a SCSI device force true Verification of setting change attribute rombb setting raid scsi force true raid Instructs the BIOS to detect RAID on motherboard channel B as a RAID device scsi Instructs the BIOS to detect the RAID on motherboard device as a SCSI device force true Verification of setting change attribute sata setting off ata raid off Disables the SATA controller ata Sets the onboard SATA controller to ATA mode raid Sets the onboard SATA controller to RAID mode omconfig Managing Components Using the Instrumentation Service 111 Table 4 3 BIOS Setup Settings on Systems Prior to PowerEdge yx2x Systems continued name value pair 1 attribute name value pair 2 setting Description attribute sataport 0 7 or a h setting off auto off Disables the SATA port auto Automatic
263. ues K NOTE This command is not supported on SAS controllers Complete Syntax omconfig storage enclosure action resettempprobes controller id enclosure lt ENCLOSUREID gt index id where id is the controller ID and the temperature probe ID The lt ENCLOSUREID gt variable specifies the enclosure 278 omconfig storage Commands Example Syntax To reset the thresholds for temperature probe 3 residing in the enclosure attached to connector 2 on controller 1 to the default values e For SCSI SATA and ATA controllers omconfig storage enclosure action resettempprobes controller 1 enclosure 2 index 3 K NOTE Here temperature probe 3 resides in the enclosure attached to connector 2 on controller 1 omconfig Set All Temperature Probe Thresholds Use the following omconfig command syntax to set the minimum and maximum warning temperature thresholds for all temperature probes in the enclosure K NOTE This command is not supported on SCSI RAID controllers Complete Syntax omconfig storage enclosure action setalltempprobes controller id enclosure lt ENCLOSUREID gt minwarn n maxwarn n where id is the controller ID The lt ENCLOSUREID gt variable specifies the enclosure Example Syntax To set the thresholds for all temperature probes residing in enclosure 3 attached to connector 2 on controller 1 to 10 and 40 degree Celsius e For SAS controllers omconfig storage enclosure action s
264. ules on the system If you specify the index Server Administrator displays a summary for a specific memory module K NOTE To maintain consistency across the commands the output format of this command has changed Change the user scripts as applicable Output for an occupied memory slot may resemble the following Index sri Status Ok Connector Name DIMM Al Type DDR3 Synchronous Unregistered lt Unbuffered gt S22 2048 MB An unoccupied memory slot still has a connector name Output for an unoccupied memory slot may resemble the following Index Status Unknown Connector Name DIMM_A2 Type Not Occupied Size omreport Viewing System Status Using the Instrumentation Service 55 If the system supports redundant memory the redundancy output may resemble the following Memory Redundancy Status Fail Over State Redundancy Configuration A ct A A octodctoaqoaocdca do ic 0 ca At e 0 ad mory mory mory mory tribu mory tribu mory Redundancy tributes of Memory Array s tributes Array 1 tributes Array 1 tributes Array 1 tributes Array 1 tes Array 1 tes Array 1 tribu mory tes Array 1 Full Inactive DDDC Location System Board or Motherboard Use System memory Installed Capacity 131072 MB Maximum Capacity 1048576 MB Slots Available 32 Slots Used 32 Error Correction ultibit ECC omr
265. urpose or department such as research and development or sales installdate Date the system was lt mmddyy gt put to service ponum lt n gt Number of the document that authorized payment for the system purchasecost Price the owner paid for lt n gt the system purchasedate Date the owner lt mmddyy gt purchased the system signauth Name of the person lt text gt who approved the purchase or the service call on the system waybill lt n gt Receipt from the carrier for the goods received 178 omconfig system or servermodule assetinfo Editing Cost of Ownership Values Example Commands for Adding Acquisition Information To provide a value for an acquisition parameter type a command of the form omconfig system assetinfo info acquisition lt name value pair 2 gt or omconfig servermodule assetinfo info acquisition lt name value pair 2 gt For example type omconfig system assetinfo info acquisition purchasedate 122101 Or omconfig servermodule assetinfo info acquisition purchasedate 122101 The following message is displayed Asset information set successfully You can type more than one omconfig system assetinfo or omconfig servermodule assetinfo command at the same time as long as all of the parameters for name value pair 2 belong to name value pair 1 For example to type more than one parameter value for info acquisition use the following example as a syntax guide omconfig system assetinfo info
266. user Sets the maximum privilege level that is accepted on a serial connection to User 143 Table 4 12 Parameters of omconfig chassis remoteaccess or omconfig mainsystem remoteaccess continued name value pair 1 name value pair 2 Description config config enable true false true Enables serial over LAN for serialoverlan the BMC baudrate 9600 19200 38400 57600 115200 false Disables serial over LAN for the BMC 9600 Sets the volatile and non volatile connection speed to 9600 bits per second 19200 Sets the volatile and non volatile connection speed to 19200 bits per second 38400 Sets the volatile and non volatile connection speed to 38400 bits per second 57600 Sets the volatile and non volatile connection speed to 57600 bits per second 115200 Sets the volatile and non volatile connection speed to 115200 bits per second NOTE Baud rates of 9600 and 19200 are supported on PowerEdge 1800 1850 2800 and 2850 systems NOTE Baud rates of 19200 and 57600 are supported on PowerEdge x9xx systems Baud rate of 115200 is supported on certain systems that have a DRAC 5 installed NOTE Baud rate of 19200 57600 and 115200 are supported on yxdxsystems that have iDRAC installed 144 omconfig Managing Components Using the Instrumentation Service Table 4 12 Parameters of omconfig chassis remoteaccess or omconfig mainsystem remoteaccess continued name v
267. vel 1 Level 3 Use fans firmware frontpanel fru hwperformance info intrusion U P A Displays the status and thresholds for system fans Displays the name and version of the firmware Displays whether the front panel button settings such as the Power button and or Nonmasking Interrupt NMI button if present on the system are enabled or disabled It also displays the front panel encryption access information and the front panel LCD information Displays the Field Replaceable Unit FRU information Displays the status and cause for the system s performance degradation Displays a status summary for main system chassis components Displays the status of the system s intrusion sensor s 34 omreport Viewing System Status Using the Instrumentation Service Table 3 2 Command Level 1 Level 2 and Level 3 for omreport continued Command Command Level 2 Level 1 Command Level 3 User Privilege Required Use leds memory nics ports processors pwrmanagement pwrmonitoring pwrsupplies U PA Rav gt aw gt U P A U PA U PA U PA Displays the properties you have set for light emitting diodes to flash under various alert conditions Displays properties of the system s memory arrays Displays the NIC and Team interface properties Displays the properties for the system s parallel and serial ports su
268. vel that is accepted on a LAN channel to Administrator operator Sets the maximum privilege level that is accepted on a LAN channel to Operator user Sets the maximum privilege level that is accepted on a LAN channel to User text Text used for encryption and confirmation of encryption NOTE The text option is supported only on PowerEdge x9xx systems Validates the preferred DNS server for configuration 141 Table 4 12 Parameters of omconfig chassis remoteaccess or omconfig mainsystem remoteaccess continued name value pair 1 name value pair 2 Description config config serial baudrate 9600 19200 9600 Sets the connection speed to 9600 38400 57600 115200 bits per second 19200 Sets the connection speed to 19200 bits per second 38400 Sets the volatile and non volatile connection speed to 38400 bits per second 57600 Sets the volatile and non volatile connection speed to 57600 bits per second 115200 Sets the volatile and non volatile connection speed to 115200 bits per second NOTE Baud rates of 9600 and 19200 are supported on PowerEdge 1800 1850 2800 and 2850 systems NOTE Baud rates of 19200 38400 and 57600 are supported on PowerEdge x9xx systems NOTE Baud rate of 115200 is supported on certain systems that have a DRAC 5 installed NOTE Baud rate of 19200 57600 and 115200 are supported on yxOxsystems that have iDRAC installed flowcontrol none rtscts none No control over the f
269. vent processorwam Sets actions when a processor probe detects a warning value event processorfail Sets actions when a processor probe detects a failure value event redundegrad Sets actions when a redundant component becomes inoperative resulting in less than full redundancy for that component event redunlost Sets actions when one or more redundant components become inoperative resulting in a lost or a no redundant components working condition for that component omconfig Managing Components Using the Instrumentation Service Table 4 23 Events for Which You Can Set Alert Actions continued Event Name Description event tempwarn Sets actions when a temperature probe detects a warning value event tempfail Sets actions when a temperature probe detects a failure value event voltwarn Sets actions when a voltage probe detects a warning value event voltfail Sets actions when a voltage probe detects a failure value event watchdogasr Sets actions that Server Administrator performs on the next system startup after a watchdog Automatic System Recovery ASR is performed for a hung operating system event removableflashmediapresent Sets actions that Server Administrator performs when the system detects a removable flash media event removableflashmediaremoved Sets actions that Server Administrator performs when a removable flash media is removed
270. vices Server Administrator is the sole installation on the system being managed and is accessible both locally and remotely from the Server Administrator home page Server Administrator enables you to access remotely monitored systems by dial in LAN or wireless connections The configuration features enable Server Administrator to perform essential tasks described in detail in the following sections This CLI guide documents all the commands that apply to Server Administrator and Storage Management Introduction 17 The reporting and viewing features enable retrieval of the overall health status for systems on the network You can view information about voltage temperature fan s revolutions per minute RPM memory functioning and many other critical details at the component level You can also see a detailed account of the cost of ownership COO about the system retrieve version information about the BIOS firmware operating system and all installed software K NOTE Use the CLI instead of the Server Administrator home page and turn the K K Server Administrator Web server off for concerns on encryption The CLI does not use the Web server Run the omconfig system webserver action stop command to turn off the Web server The Web server starts automatically after a reboot so run this command each time the system starts up For more information see omconfig system webserver or omconfig servermodule webserver on page 171
271. word gt Sets the new SNMP root password confirmnewpw lt newpassword gt Confirms the new SNMP root password When you type omconfig preferences snmp setting rootpw the system prompts you to supply values for the required parameters When you type omconfig preferences snmp you must supply all the parameters in the initial command line For example omconfig preferences snmp setting rootpw oldpw openmanage newpw serveradmin confirmnewpw serveradmin omconfig Managing Components Using the Instrumentation Service 155 Table 4 19 SNMP Set Operations Parameters name value pair Description setting snmpset Required enable true Enables SNMP set operations enable false Disables SNMP set operations For example to disable SNMP set operations use the following command omconfig preferences snmp setting snmpset enable false K NOTE After executing the command to enable or disable SNMP set operations restart services for the change to take effect On systems running supported Microsoft Windows operating systems restart the Windows SNMP Service On systems running supported Red Hat Enterprise Linux and SUSE Linux Enterprise Server operating systems restart Server Administrator services by running the srvadmin services sh restart command omconfig preferences useraccess Depending on the policies of your organization you may want to restrict the access that some user levels have to Server Admini
272. ype removableflashmedia Removable flash media omconfig Managing Components Using the Instrumentation Service 169 Severity In the context of configuring events severity determines how severe an event is before Server Administrator notifies you of the event for a component type When there are multiple components of the same type in the same system chassis you can specify whether you want notification for event severity according to the number of the component by using the index lt n gt parameter Table 4 28 lists the valid severity parameters Table 4 28 System Event Severity Parameters Command Result Description omconfig system events type Enables notification Least restrictive form of lt component name gt severity info for informational event notification or warning and critical omconfig servermodule events events type lt component name gt severity info omconfig system events type Enables notification Omits informational event lt component name gt severity for warning and notification for example warning critical events when a component returns or to normal status omconfig servermodule events type lt component name gt severity warning omconfig system events type Enables notification Restrictive form of event lt component name gt severity for critical events notification critical only or omconfig servermodule events type lt component name gt severity critical
273. ystem Status Using the Instrumentation Service The following is an example output Power Inventory and Budget Power Inventory System Idle Power OW System Maximum Potential Power OW Power Budget Attribute Enable Power Cap Values Enabled Attribute Power Cap Values 400 W 56 K NOTE Power budget requires license to report the details If the appropriate license is not installed or has expired the system does not display the power budget details For more information see 7he Dell Licensing Management Guide at dell com support manuals omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring Use the omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command to view the properties of the system s power consumption The values display either in Watts or BTU Hr based on the configuration Type omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring For each power monitoring profile in the system values display for the following fields e Power Consumption Status e Probe Name e Reading e Warning Threshold omreport Viewing System Status Using the Instrumentation Service 63 K Failure Threshold Amperage Location and Reading Power Tracking Statistics Energy Consumption Measurement Start Time Measurement Finish Time Reading System Peak Power System Peak Amperage NOTE The omreport chassis pwrmonitoring or omreport mainsystem pw
Download Pdf Manuals
Related Search
Related Contents
Blackwire® C710™/C720™ Jamo A 402 名称未設定 2 Télécharger la fiche produit - myriad anti LA NOUVELLE VISION CREATIVE Swann SWVID-PEN4GB Mega Pack Manual FR Administrator Guide VTech mi6861 User's Manual Sears D71 User's Manual Copyright © All rights reserved.
Failed to retrieve file