Home

Datalogic Scanning Datalogic Jet User's Manual

image

Contents

1. Power Supply Each Ethernet Multi Cradle requires a power supply to be connected to the cradle We recommend the DL FPS18 power supply VEXT GND Figure 5 Power Supply Polarity Datalogic Mobile S r l Via S Vitalino 13 Bologna Italy C 07 40012 Lippo di Calderara dichiara che declares that the d clare que le bescheinigt da das Ger t declare que el DL JET Ethernet Desk Multi Cradle e tutti i suoi modelli and all its models et tous ses mod les und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate are in conformity with the requirements of the European Council Directives listed below sont conformes aux sp cifications des Directives de l Union Europ enne ci dessous den nachstehenden angef hrten Direktiven des Europ ischen Rats cumple con los requisitos de las Directivas del Consejo Europeo seg n la lista siguiente 89 336 EEC EMC Directive e 92 31 EEC 93 68 EEC emendamenti successivi and further amendments et ses successifs amendements und sp teren Ab nderungen y succesivas enmiendas Basate sulle legislazioni degli Stati membri in relazione alla compatibilit elettromagnetica ed alla sicurezza dei prodotti On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety Bas e sur la l gislation des Etats membres relative la compatibilit lectromagn tique et la s curi
2. that a link is established When it is not lit it indicates that there is no link The Speed LED and the Link LED integrated in Ethernet Port 1 and 2 function in the same way The Charging Status LED on the mobile computer shows the status of the battery charging The maximum time required to recharge a completely run down battery pack is about 2 5 hours for Li lon batteries See Datalogic Jet Users Manual par 3 5 1 for Charging Status LED indications Correct Mobile Computer Insertion Removal Insert the mobile computer into a slot to begin charging and start communication For correct insertion onto the cradle insert the mobile computer from the top of the cradle and push it down firmly Figure 2 Mobile Computer Insertion To remove the mobile computer from the Datalogic Jet Ethernet Multi Cradle simply pull it upwards while holding the cradle firmly down TECHNICAL FEATURES Electrical Features Power supply from 12 to 14 VDC 5 Consumption Max 4 2 A Ethernet Speed LED green Interface Working temperature 0 to 50 C 32 to 140 F 20 to 70 C 4 to 158 F Storage temperature Humidity 90 non condensing Degree of protection Dimensions 480 x 110 x 190 mm 18 89 x 4 33 x 7 48 in Weight about 2750 g 97 oz Recommended DL power supply FPS18 Batteries must be charged at a temperature ranging from 0 to 45 C 32 to 113 F Kk CONNECTIONS Connections shou
3. ld always be made with power OFF CAUTION Ethernet Connection Connect the Ethernet cradle Ethernet port 1 to an Ethernet hub or a port on the host device Connect the Ethernet cradle power port to power supply Figure 3 Ethernet Connection A Datalogic Jet Ethernet Multi Cradle B 94ACC4595 FPS18 power supply without power cord 94ACC1150 Power cord EU 3 pin C UTP CAT 5E cable recommended use D Ethernet hub Daisychaining Ethernet Connection To connect several cradles to an Ethernet network Ethernet cradles may be daisychained It is recommended not to connect more than 4 cradles in order to maintain the optimal baud rate The Speed LED and the Link LED on the Ethernet Port 2 function in the same way as the Speed LED and the Link LED on the front of the cradle To daisychain cradles 1 Connect the first Ethernet cradle to power and to the Ethernet Switch as shown on Figure 4 2 Connect power to the second Ethernet cradle 3 Connect the daisychain Ethernet cable either straight or twisted cable can be used between Ethernet Port 2 of the first cradle and Ethernet Port 1 of the second cradle 4 Connect additional cradles as shown in Figure 4 fn Ei see Figure 4 Daisychaining Ethernet Connection Key A Ethernet hub B Ethernet Port 1 C Ethernet Port 2 D 94ACC4595 FPS18 power supply without power cord 94ACC1150 Power cord EU 3 pin E UTP CAT 5E cable recommended use
4. t des produits ber die Ann herung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Vertr glichkeit und Produktsicherheit entsprechen Basado en la aproximaci n de las leyes de los Pa ses Miembros respecto a la compatibilidad electromagn tica y las Medidas de seguridad relativas al producto Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti This declaration is based upon compliance of the products to the following standards Cette d claration repose sur la conformit des produits aux normes suivantes Diese Erkl rung basiert darauf da das Produkt den folgenden Normen entspricht Esta declaraci n se basa en el cumplimiento de los productos con la siguientes normas EN 55022 CLass A ITE AUGUST 1994 LIMITS AND METHODS OF MEASUREMENTS OF RADIO AMENDMENT A1 CLASS A ITE OCTOBER 2000 DISTURBANCE OF INFORMATION TECHNOLOGY EQUIPMENT EN 55024 SEPTEMBER 1998 INFORMATION TECHNOLOGY EQUIPMENT IMMUNITY CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENTS Rote AOR PX Paola Chientaroli Lippo di Calderara August 22nd 2007 Quality Assurance Manager
5. wVWATALOGIC Datalogic Jet Ethernet Multi Cradle The Datalogic Jet Ethernet Multi Cradle provides power for charging up to four mobile computers simultaneously and also connects up to four mobile computers to an Ethernet network Figure 1 Datalogic Jet Ethernet Multi Cradle General View Key A Link LED for Ethernet Port 1 B Speed LED for Ethernet Port 1 C Datalogic Jet Charging Status LED D Power supply connector E Ethernet Port 1 with integrated Link and Speed LEDs F Ethernet Port 2 with integrated Link and Speed LEDs 822000751 Rev A The Ethernet cradle drivers are pre installed on the Datalogic Jet and initiate automatically when the Datalogic Jet is placed in a properly connected Four Slot Ethernet cradle When the mobile computer is inserted into the Four Slot Ethernet cradle the LAN icon indicates that the mobile computer is connected to a network Ethernet communication requires Datalogic Jet PDA SW version 5 41 or later Verify the software version by tapping on Software Version in the Datalogic default home page Otherwise search for the file version htm under the Windows folder The green Speed LED lights to indicate that the transfer rate is 100 Mbps When it is not lit it indicates that the transfer rate is 10Mbps The maximum bandwidth capacity for each Mobile Computer is 12Mbps The yellow Link LED blinks to indicate activity or stays lit to indicate

Download Pdf Manuals

image

Related Search

Related Contents

USER`S MANUAL  P1L - 4 dimmer User Manual V2.cdr  Untitled - Caframo Lab Solutions  Por favor haga clic aquí para descargar manual de Instalación y  E G O User`s Manual H  Bedienungsanleitung  Timex 568-095003 Watch User Manual  Olympus M.ZUIKO DIGITAL ED 8mm 1:1.8 Fisheye Pro  DVD PLAYER BEDIENUNGSANLEITUNG  Echo 39.indd  