Home
Dacor MRES30 User's Manual
Contents
1. oN fe te Tet N 7442 38mm 4 t l 24 19 7 16 eqn 619mm Front face of cabinet peice l 25 23 16 113 8 25mm 556mm 289mm Location of Anti Tip Bracket Top View Removing the Oven Door 4 WARNINGS 1 Do not attempt to disengage the hinge catches with the door removed from the oven 5 The hinge springs could release causing personal injury 6 2 Do not lift or carry the oven door by the door handle Open the door to its fully opened position Rotate the catch over the retaining arm on each hinge Lift the oven door to about a 30 degree angle from the horizontal position Pull the door away from the oven while continuing to lift Do not install a fuse in the neutral or ground circuit A fuse in the neutral or ground circuit may result in an electrical shock hazard Do not ground the appliance to a gas supply pipe or hot water pipe A grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials Any insulating materials must be jumped with a length of No 4 copper wire securely clamped to bare metal at both ends Grounding Instructions All Models This appliance must be electrically grounded With the range positioned directly in front of the cabinet cutout feed the appliance conduit to the electrical junction box Then depending upon local codes utilize one o
2. NOTE 1 Some products such as whole eggs and sealed containers such as closed glass jars may explode and should not be heated on this cooktop AJ WARNING NEVER cover any slots holes or passages in the oven bottom or cover an entire rack with materials such as aluminum foil Doing so blocks air flow through the oven and may cause carbon monoxide poisoning Aluminum foil linings may also trap heat causing a fire hazard WARNING NEVER use this appliance as a space heater to heat or warm the room Doing so may result in carbon monoxide poisoning and overheating of the appliance Range Data Plate Location the range data plate specifies the model number serial number electrical supply and gas supply requirements if applicable On models MRES30 and RSE30 it is located on the left side wall inside the range storage compartment On model RSD30 it is located inside the door behind the grate at the top Data Plate Location Models MRES30 RSE30 Data Plate Location Model RSD30 Verifying the Package Contents If any item is missing or damaged please contact your dealer immediately Do not install a damaged or incomplete appliance All Ranges e Use amp Care Manual e Anti tip Bracket e Broiler Grill and Pan e Oven Racks Ranges w Gas Top Burners amp MRES30 Only e Ignitor Cleaning Kit e Burner Ring Set e Grate Burner Cap Pack e Simmer Plate Electric Ranges Only e Raz
3. both sides ile Overall Cabinet Dimension and Clearance to Combustible Surfaces Vertical non combustible Backsplash surface rear wall NN a 27 7 8 708mm e a thicker than 1 rs as 3 4 19mm Le 77 TSN qt eed Pa N l Pies 1 e oes a ry pne i 1mm d 7 i 1 4 6mm i 7 Min flat ledge s 1 oe 27 13 16 706mm Adjust for backsplash over 3 4 thick from 13 16 to 3 13 16 a fab ERE ee 21 97mm 13 32 10mm Cae 29 1 4 743mm 30 1 16 764mm Countertop overhangs cabinet 10 254mm Min to combustible side walls above the range both sides Downdraft ERV30 with Slide In Self Rimming Installation using 3 Side Panels Numbers ARSR30 and ARSL30 with Backguard Removed Top View Backsplash 7 Si 1 Hl 1 4 6mm Vertical Min flat ledges non combustible Ress Wall Serr surface rear wall Seay so eS si 25 635mm Adjust for backsplash i thickness i 13 16 to 4 1 4 ia 21 108mm AE 2 28 11 16 729mm hn I 29 5 8 752mm 17mm Slide In Self Rimming Installation using 3 Side Panels Part Numbers ARSR30 and ARSL30 Backguard Removed Top View 3 gacor Overall Dimensions 60 1542mm Long 240V 4 wire 5 16 1 13 16 8 46mm gt Gas Connection Removable factory inst
4. ia OOOO OOOO MRES SLEW UP DOWN Range Control ON OFF NOTES If either the oven or cooktop does not operate properly follow these troubleshooting steps 1 Verify that power all ranges and gas RSD are supplied to the range 2 Check the electrical connections all ranges and gas RSD supply to ensure that the installation has been completed correctly 3 Repeat the above burner ignition test RSD 4 Ifthe appliance still does not work contact an authorized DACOR service company at 800 772 7778 Do not attempt to repair the appliance yourself DACOR is not responsible for service required to correct a faulty installation gacor 6 Specifications contained within are subject to change without notice No liabilty is assumed by DACOR for changes in specifications The information and images in this book are the copyright property of Distinctive Appliances Inc Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Distinctive Appliances Inc Web Site www Dacor com Corporate Phone 800 793 0093 Copyright 2006 Dacor all rights reserved
5. the range A manual shut off valve must be installed in the gas piping external to the appliance for the purpose of turning on or shutting off gas to the appliance Plan the location of the range and the gas supply to allow access to the valve when the unit is installed and in operation Access to the remote circuit breaker panel fuse box with the range in place and operating must also be allowed for in the installation Any openings in the wall behind the appliance and in the floor under the appliance must be sealed Both the gas supply piping and shut off valve and the electrical junction box receptacle must be located so they do not interfere with the range when it is installed and under operation In addition the junction box must be located so the range can be removed for service when the conduit supplied with the unit is attached to the junction box Do not lengthen the conduit or wiring provided with the range All dimensions shown are based on standard American cabinets 36 inches 914mm high at the finished countertop by 24 inches 610mm deep with a 25 inch 635mm overall countertop depth When installing the range into nonstandard cabinets minimum clearances shown in the diagrams must be maintained Carefully check the location where the range is to be installed For best performance the range should be placed away from drafts that may be caused by doors windows and HVAC outlets Cabinet and Countertop Pre
6. alled 3 76mm Side Panels RSD30 Overall Dimensions Dual Fuel Isometric View 60 1524mm Long 240V 4 wire conduit location xA K 35 889mm 5 16 1 13 16 8 46mm gS WN Removable factory installed 3 76mm Side Panels RSE30 MRES30 Overall Dimensions All Electric Isometric View RSE30 Shown 30 O o 762mm i j g 23 1 2 Range Top 597mm 26 9 16 Rear of Control 675mm Panel Oven Door See oe Oe ee y _1 Max depth to oven door Door Opened handle with door closed 45 1 4 1149mm e Overall Dimensions Preference Models Isometric View 30 762mm 4 4 23 1 2 Range Top 597mm 25 5 16 Rear of Control 643mm Panel Oven Door Ai _ 1 Max depth to oven door handle with Door Opened door closed 45 1 4 1149mm E ee Overall Dimensions MRES Model Isometric View Installing the Anti Tip Bracket WARNING This appliance require an anti tip device Before installing the range you must locate and secure the anti tip bracket to the floor When the range is slid into position in the cutout the left rear leveling leg slides into this bracket to prevent the unit from tipping forward The bracket location shown here will position the rear edge of the range top frame flush to the rear wall From this position the bracket allows for up to 5 8 16mm of forward movement of the range
7. ave its own high pressure regulator This is in addition to the pressure regulator provided with the range Separate No 10 minimum copper grounding wire O Clamp must be tight on pipe No 4 copper wire Metal water pipe Connecting the appliance ground to a grounded junction box wire or grounded cold water pipe 5 dacor 5 The maximum gas supply pressure to the appliance gas pressure regulator must never exceed 1 2 pound per square inch 3 5kPa NOTE The applaince gas pressure regulator is pre set at the factory for the type of gas intended for use with the appliance Verify that the appliance is compatible with the type of gas available by checking the data plate located behind the inlet air cooling grill Ranges intended for use with LP gases will have LP as a part of the model number Consult your dealer if the range is not compatible with your gas supply Installing the Range Measure from the floor to the countertop and adjust the leveling legs as required to position the top frame at the desired height based on the cabinet and countertop installation Carefully slide the range into position in the cutout The left rear leveling leg should engage the anti tip bracket When the range is to be installed as a slide in self rimming with the range top overhanging the countertop cutout measure from the floor to the countertop Adjust the leveling legs to position the botto
8. e power supply All Models dacor 4 WARNING Do not connect the green appliance wire to the neutral white supply wire unless local building codes permit Cable from power supply Wire nut 3 places Conduit from appliance Connecting the appliance to a three wire power supply RSE MRES30 Only WARNING The RSD30 cannot be connected as above because it will damage the spark module B Connecting the Green Appliance Wire to the Neutral White Supply Wire Where Local Codes Permit RSE MRES30 Only 1 Connect the green and white appliance wires to the neutral white supply wire in the junction box 2 Connect the black appliance wire to the black L1 power supply wire in the junction box 3 Connect the red appliance wire to the red L2 power supply wire in the junction box C Connecting the Green Appliance Wire to a Grounded Supply Wire or a Grounded Cold Water Pipe Where Local Codes Permit All Models 1 Separate the green and white appliance wires 2 Connect the white appliance wire to the neutral white supply wire in the junction box 3 Connect the black appliance wire to the black L1 power supply wire in the junction box Cable from power supply WHITE WHITE BLACK BLACK J Wire nut 4 places Conduit from appliance 4 Connect the red appliance wire to the red L2 power supply wire in the ju
9. f the following techniques to connect the appliance to the A 1 2 Lift door up to 30 angle then pull door away from the oven To remove door rotate catch up 4 Removing the Oven Door Remove the Kick Panel All Models Remove the screw at each top corner of the kick panel Lift up slightly on the panel and pull forward to remove Electrical Connection NOTE See the range data plate for electrical specifications See page 1 for location WARNINGS All of these range models must be connected to a grounded metallic permanent wiring system Alternatively a grounding conductor should be connected to the grounding terminal or lead on the appliance 3 Do not use an extension cord with this appliance Such use may result in fire electrical shock or other personal injury 1 electrical power supply Connecting to a Four Wire Electrical System Recommended for All Models Separate the green and white appliance wires Connect the white appliance wire to the neutral white supply wire in the junction box Connect the black appliance wire to the black L1 power supply wire in the junction box Connect the red appliance wire to the red L2 power supply wire in the junction box Connect the green appliance wire to the green house grounding wire in the junction box Cable from power supply Wire nut 4 places Conduit from appliance Connecting the appliance to a four wir
10. gacor The Life of the Kitchen Installation Instructions Preference and Millennia Ranges For use with models MRES30 RSD30 RSE30 SAVE AND READ THESE INSTRUCTIONS TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21 1 STANDARD FOR HOUSEHOLD GAS COOKING APPLIANCES CONVENTIONS USED IN THESE INSTRUCTIONS WARNINGS Must be followed carefully to avoid personal injury or damage NOTES Contain helpful hints and tips to facilitate the installation IMPORTANT Before beginning installation please thoroughly read and become familiar with these instructions Installation and service must be completed by a qualified installer or service agency Installer Please leave these Installation Instructions with the owner Owner Please keep these instructions for local electrical inspector s use and for future reference Read the accompanying Use amp Care Manual prior to operating this appliance OF ON TABLE OF CONTENTS STEP 1 Verifying package contents Page 2 STEP 2 Gas supply requirements Page 2 STEP 3 Electrical power supply requirements Page 2 STEP 4 Gas and electrical rough in locations Page 2 STEP 5 Cabinet and countertop preparation Page 2 3 STEP 6 Overall dimensions Page 3 4 STEP 7 Installing the anti tip bracket Page 4 STEP 8 Removing the oven door Page 4 STEP 9 Removing the kick panel Page 4 STEP 11 Electrical connection Page 4 5 STEP 12 Gas connection Page 5 STEP 13 Installing the range Page 5 STEP 14 I
11. king appliance Never use it for warming or heating a room 1 gacor 10 11 12 13 14 15 16 This appliance must not be used in combination with surface countertop ventilation systems The use of an overhead hood or Dacor Raised Vent is recommended for ventilation This appliance must be installed with the gas pressure regulator supplied with it Disconnect the electrical supply before installing or servicing the appliance This appliance must be grounded Connect only to a properly grounded electrical supply Refer to Electrical Requirements Install or locate this appliance only in accordance with these installation instructions Use this appliance only for its intended use as described in this manual Do not use corrosive chemicals or vapors in this appliance This type of appliance is not designed for industrial or laboratory use As with any appliance close supervision is necessary when used by children Do not operate this appliance if it has a damaged electrical cord plug conduit or wires if it is not working properly or if it has been damaged or dropped Installation of this appliance must be performed by a qualified installer service agency or the gas supplier This appliance should be serviced only by qualified service personnel Contact the nearest DACOR Authorized Servicer at 800 772 7778 or at www dacor com for examination repair or adjustment
12. m edge of the range top frame approximately 1 8 13mm above the level of the countertop This will allow the range to slide over the countertop Carefully slide the range into position in the cutout Again the left rear leveling leg should engage the anti tip bracket To lower the range onto the countertop turn the leveling legs counterclockwise Lower the range until the bottom of the range top just contacts the countertop Do not allow the full weight of the range to hang on the counter Installing the Burner Components Remove the brass burner rings porcelain burner caps and porcelain gates from their shipping packages Place each burner ring onto its corresponding burner base being certain that the five alignment tabs slide into the matching notches in the base Set each porcelain burner cap on top of its corresponding burner ring Place each grate onto the top frame being certain that the rubber feet are positioned in the locating dimples WARNING Never attempt to operate the cooktop section of the range with any of the burner rings burner caps or grates removed NOTE Prior to operating the cooktop or oven sections of the range please read the accompanying Use and Care Manual carefully Important safety service and warranty information is contained within this manual Re installing the Oven Door Grasp the oven door on opposite sides and lift it until the door hinges are aligned with the openings in the
13. nction box 5 Connect the green appliance wire to a grounded supply wire in the junction box or to a grounded cold water pipe 6 If connecting to a grounded cold water pipe a separate copper grounding wire No 10 minimum must be connected to a grounded cold water pipe by means of a clamp and then to an external grounding connector screw 6 A grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials Any insulating materials must be jumped with a length of No 4 copper wire securely clamped to bare metal at both ends Gas Connection Before sliding the range into the cabinet connect a flexible gas connector to the gas shut off valve previously installed on the stub out The gas valve must be turned off during installation Connect the flex connector to the pipe fitting at the right rear of the range WARNINGS 1 Do not apply excessive pressure when tightening gas connections and fittings 2 Do not use teflon tape or plumber s putty on gas flex line connections 3 Turn all cooktop control valves to the OFF position Turn on gas supply and check all lines and connections for gas leaks using a soap and water solution Do not use a flame to check for leaks After verifying that there are no gas leaks turn off the gas supply to the range by turning the gas shut off valve to the OFF position 4 ForLPinstallations the LP gas tank must h
14. nstalling the burner components Page 5 STEP 15 Re installing the oven door Page 5 STEP 16 Verifying proper operation Page 6 Part No 65166 Rev J IMPORTANT SAFETY INSTRUCTIONS WARNINGS 1 Read all instructions before using the appliance 2 Ifthe information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death 3 Improper installation adjustment alteration service or maintenance can cause personal injury or property damage Refer to these instructions and the accompanying Use amp Care Manual For assistance or additional information consult a qualified installer service agency manufacturer dealer or the gas supplier 4 What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call the gas supplier from a neighbor s phone e Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department 5 For your safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not obstruct the flow of combustion and ventilation air to the unit Keep appliance area clear and free from combustible material Do not use or attempt to use this appliance in the event of a power failure 6 This unit is designed asa coo
15. or Blade Scraper e Cooktop Cleaning Cream Gas Supply Requirements Check your local building codes for the proper method of installation In the absence of local codes this appliance should be installed in accordance with the National Fuel Gas Code ANSI 2223 1 Be certain that the appliance being installed is correct for the gas service being provided WARNING This appliance must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts Electrical Power Supply Requirements It is the owner s responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician The electrical installation including minimum supply wire size and grounding must be in accordance with the National Electric Code ANSI NFPA 70 2002 or latest revision and local codes and ordinances A copy of this standard may be obtained from National Fire Protection Association 1 Batterymarch Park Quincy Massachusetts 02269 9101 The correct voltage frequency and amperage must be supplied to the appliance from a separate grounded circuit that is protected by a properly sized circuit breaker or time delay fuse Refer to the data plate and or the Table above for gas supply requirements WARNING If the gas or electric service provided does not meet the product specifications do not proceed with the installation Call the selling dealer the gas s
16. oven frame Holding the door at about a 30 angle from the horizontal slide the hinges into the openings until the bottom hinge arms drop fully into the hinge receptacles Lower the door to the fully opened position and then rotate the two hinge catches toward the oven Open and close the door completely to ensure that it is properly installed Peel off the protective layer of plastic that covers the door panel Verifying Proper Gas Operation of the Dual Fuel Ranges RSD WARNINGS 1 The range and shut off valve must be disconnected from the gas supply piping during any pressure testing exceeding 1 2 psi 3 5kPa 2 The range must be isolated from the gas supply piping by closing the shut off valve during any pressure testing at or below 1 2 psi 3 5 kPa Before beginning the test procedure ensure that all cooktop section control valves are in the OFF position and all burner rings burner caps and grates are properly positioned on the top frame Turn on the gas supply at the shut off valve Turn on the power supply to the range Set the time of day by pressing the CLOCK key and then pressing either of the TIME TEMP keys or keys to advance or reduce the time in the display in the desired setting Test each top burner separately by pressing and turning one control knob at a time counterclockwise to the HIGH position All ignitors will spark continuously but only the burner wi
17. paration NOTES If cabinet storage space is to be provided directly above the range the risk of personal injury may be reduced by installing a ventilating hood that projects horizontally a minimum of 5 inches 127mm beyond the face of the cabinets 2 The range may be installed flush to the rear wall We recommend installing a non combustible material on the rear wall above the range and up to the vent hood It is not necessary to install non combustible materials behind the range below the countertop height 3 The minimum distance from the sides of the range above the countertop to combustible side walls must be at least 6 inches 152mm gacor 2 Utilities may be located 1 In the lower left corner of the adjacent right cabinet Recommended 2 Alternate location in the lower right corner behind the range Note Some building departments do not permit concealing gas valves behind appliances Contact your local building department to verify compliance with local code interpretation a NN A Pi oe a Pi d 36 914mm Recommended 30 762mm Min ya ae x ae S 25 Y iS 635mm S E Vertical Top of combustible finished Si P surface oe counter ae D Z 30 762mm 30 1 16 lt 18 457mmy i Min 764mm g 10 254mm Min Min S i Pa 254mm r to combustible side 7 A 10 7 a walls above the range 14
18. th gas flowing to it will ignite It will take approximately 4 seconds for ignition to occur at which time the ignitors will stop sparking If ignition does not occur within 4 seconds turn off the knob wait for at least 2 minutes to allow any gas to dissipate then repeat this ignition test The control knob can then be rotated counterclockwise from HIGH to LOW to adjust the flame height size progressively Repeat the ignition test for all top burners When installed properly the flame will be steady and quiet It will also have a sharp blue inner cone that will vary in length proportional to the Verify Proper Operation for Electric Ranges RSE and MRES For RSE range top rotate one surface element knob at a time counterclockwise to the HI position Within 5 seconds the element should be fully energized and glowing red Verify that the residual heat indicator light comes on in conjunction with the proper element within approximately 30 seconds Return the knob to the OFF position Repeat for all surface elements Note The right front element is a dual coil element Clockwise rotation from LO to HI will energize the inner coil only Counterclockwise rotation from LO to HI will energize both the inner and outer coils together For MRES range top turn an element tap the ON OFF key then tap the slew up down area of the desired element The element will come on at a se
19. tting of the number touched and may be adjusted up or down by slewing up or down on the appropriate key area with your finger To activate the Dual Outer Element tap the circle key at the end of the slew area second row then tap or slew your finger up or down on the second row of numbers The outer ring element will come on at a setting of the number touched last To turn the element off tap the ON OFF key You may turn off all active elements at the same time by tapping twice on the CANCEL SECURE key located below the controls NOTE When the MRES unit is powered on for the first time the cooktop control will go through a self check routine When the self check is complete the cooktop control will go to SECURE mode See Use and Care Manual for Secure Mode instructions Within 5 seconds the element should be fully energized and glowing red Verify that the residual heat indicator light comes on in conjunction with the proper element within approximately 30 seconds Off Position Knob Position Indicator Low Polished Surface a Position Light amp High Position Area of Operation RSD Dual Fuel Range Control Knob Knob Position Indicator Polished Surface Off Position Low tow Position Position Area of Operation Both Coils A Inner Coil High Position RSE Range Control Knob 0O Kier OOOOOOOOO Ee ON OFF oo SO HEEE ETa an Ee ON OFF O oS 1Ceerereso ON OFF OO o
20. upplier or a licensed electrician Dedicated electrical circuit required Total connected load Dacor Model Number RSD30 120 240VAC 60Hz 30A RSD30LP 5 4kW 23 3A RSE30 120 240vac 111kW 46 7 4 wire 60Hz 50A 10 3kW 43 7A N A Min gas Manifold supply Gas type pressure pressure 4 water 5 water Natural column column fee 10 water 11 water N A Gas and Electrical Requirements The above electrical specifications are for reference only See the range data plate for exact specifications See page 1 for location NOTES 1 The power supply must be properly polarized Reverse polarity will result in continuous sparking of the electrodes even after flame ignition 2 Ifthere is any doubt as to whether the power supply is properly polarized or grounded have it checked by a qualified electrician 3 Ifthe appliance is connected to a 120 208 volt power supply preheat times and cavity temperature recovery times will be increased slightly Gas and Electrical Rough In Locations NOTE The shaded areas shown in the illustrations denotes the location of the gas stub and the electrical junction box receptacle These are suggested locations For replacement purposes the location of the existing utilities may be utilized provided that they do not interfere with the sides or rear of the range Verify that local building codes will permit installing the gas valve behind
Download Pdf Manuals
Related Search
Related Contents
Baby Trend Compact Back Pack 2512 User's Manual StarTech.com 2 Port ExpressCard SuperSpeed USB 3.0 Card Adapter with UASP Support Nr. 07 - Urma AG PUT YOUR THESIS TITLE HERE sais¢n 14.15 - Orchestre national d`Ile-de bedienungsanleitung tragbare motorheckenschere echo Manuel d`installation de ProxyEcoles Rako Curtain, Blind and Screen Modules Copyright © All rights reserved.