Home

Dacor DR30GIFS User's Manual

image

Contents

1. max Countertop thickness 1 5 8 4 1 cm max f 10 min 25 4 cm 1 Non combustible 1 to any combustibles Rea wallet 3 4 min 1 9 cm rear wall required countertop a countertop overhang 10 min 25 4 cm to any combustibles above counter both sides above counter both sides 21 7 20 3 4 53 3 cm 21 1 8 25 5 8 29 1 4 74 3 cm gt ne ere 53 7 cm max countertop opening 24 29 1 4 74 3 cm gt t 65 1 cm 30 76 2 cm ae 65 4 cm countertop opening ba ie cabinet opening 61 0 cm max 30 76 2 cm below countertop 3 cabinet opening 61 3 cm Notch countertop ____ _ below countertop to width of cabinets _ __ Notch countertop ______ Cabinet face ease width of cabinets below countertop 4 Cabinet face Countertop front below countertop CABINETS LESS THAN 24 DEEP 3 1 4 SIDE PANELS CABINET DEPTH GREATER THAN 24 2 INSTALLED RANGE BACK FLUSH TO WALL TOP VIEW 3 1 4 SIDE PANELS INSTALLED RANGE BACK OVERHANGING COUNTERTOP TOP VIEW 10 min 25 4 cm mi 1 10 min 25 4 cm to any combustibles None sigpusiye m Rear wall or 1 min 2 5 cm rear wall required to any combustibles tertop ed above counter both sides above counter both sides COYN E IOP E99e Countertop overhang A Y
2. 7 29 1 4 74 3 cm gt countertop opening 24 29 1 4 74 3 cm gt x 61 0 countertop opening 24 1 8 30 76 2 cm 61 0 cm 61 3 cm cabinet opening oe Vir cm below countertop eee opening z Cabinet f below countertop l abinet face Cabinet face O below countertop Net below countertop iP Notch countertop gt _ E Notch countertop gt overhang to width of 4 overhang to width of cabinets Countertop overhang cabinets Countertop overhang 1 5 8 4 1 cm max 1 5 8 4 1 cm max CABINET EXACTLY 24 DEEP 3 1 4 SIDE PANELS CABINET DEPTH GREATER THAN 25 1 8 2 REMOVED RANGE BACK FLUSH TO WALL TOP VIEW 3 1 4 SIDE PANELS REMOVED RANGE BACK OVERHANGING COUNTERTOP TOP VIEW 1 On models DR30GIS and DR30GIS non combustible surface required immediately behind range as specified on previous page when back of backguard is less than 2 1 2 6 4 cm from rear wall 2 Models DR30GIS and DR30GIS include self rimming trim piece that attaches to back of range and covers the edge of the countertop overhang in back 3 To create a built in look on the front of the cabinet this dimension may be changed to 29 1 4 74 3 cm This configuration is only for models DR30GIS and DR30GIS with side panels behind door removed All specifications subject to change without notice www dacor com Phone 800 793 0093 DR3OGS DR30GFS DR3OGIS DR3SOGIFS Document PG05 007
3. gt A I 2 1 2 6 4 cm 1 2 5 cm 31 2 1l 8 9 cm lt gt 1 10 8 cm UTILITY CLEARANCE BEHIND RANGE BACK OF RANGE ELECTRICAL REQUIREMENTS GAS SUPPLY PRESSURE REQUIREMENTS Electrical Circuit Total Connected Gas Manifold Min Gas Supply Max Input Required Load Type Pressure WC Pressure WC Pressure IMPORTANT The information above is for reference only If the above data does not agree with the product data label use the data on the product data label The gas inlet on the regulator accommodates a 1 2 NPT gas line connection The range can also accommodate a 3 4 NPT gas line connection by removing the 1 2 to 3 4 adapter on the regulator inlet All specifications subject to change without notice www dacor com Phone 800 793 0093
4. 5cm copper 30 76 2 cm min clearance between top of range grates and bottom of unprotected wood or metal cabinet If installing range hood check the hood specifications for minimum required clearances 2 Cabinet countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel See Product Dimensions 3 Consult local code and following pages for requirements 4 This specification not applicable for cabinets more than a horizontal distance of 10 25 4 cm from edge of range 5 40 25 4 cm min to combustible sidewalls above range both sides 8 Non combustible surface required for models DR30GIS and DR30GIFS up to vertical distance specified in note 1 or range hood whichever is lower Non combustible surface recommended but not required for models DR30GS and DR30GFS All specifications subject to change without notice www dacor com Phone 800 793 0093 DR3OGS DR30GFS DR3OGIS DR3OGIFS Document PG05 007 Revised 04 04 13 Page 3 5 Distinctive 30 Wide PLANNING dacor All Gas Ranges GUIDE Self Rimming Installation custom Cutout Options Models DR30GIS and DR30GIFS Only NOTE The diagrams below are for installations that require custom cutouts See page 5 5 for installation in standard 30 inch wide cutout All tolerances 1 16 1 6 mm 0 unless otherwise noted For all self rimming installations Countertop height 34 3 4 88 3 cm min 36 7 8 93 7 cm
5. DEPTH 2 PARTIAL SIDE PANELS INSTALLED TOP VIEW D eee ee ew ee ee Ee eH m De i I i l T T 4 I I I l I I l l i I I I 1 I I I I i I l I I 4 j i I T IMPORTANT If optional side panels are not installed cabinet face must be flush with back of control panel SIDE VIEW DR3OGI F S RANGE AND 10 min 25 4 cm ERV3015 RAISED VENT to any combustibles Rear wall or above counter both sides countertop edge Paar 3 8 9 5 mm min een A Rear wall or A e j countertop overhan countertop overhang 3 7 6 cm above counter both sides courtertop edge g i i g m 27 1 2 69 9 cm gt a g 27 1 2 69 9 cm raised vent opening A j e raised vent opening A 4 1 1 3 29 1 4 74 3 cm gt 20 7 8 29 1 4 74 3 cm 7 6 cm countertop opening 20 5 8 53 0 cm countertop opening 24 1 8 30 76 2 cm 52 4cm to 30 76 2 cm 61 3 cm cabinet opening 24 1 8 cabinet opening below countertop 61 3 cm below countertop Cabinet face Notch countertop below countertop overhang to width of gt 7 ee es e a Yo J cabinets Notch countertop __ overhang to width of Cabinet face cabinets Countert h Countertop ountertop overnang front below countertop 1 5 8 4 1 c
6. DR3OGS DR3OGFS D Document PG05 007 dsacor Distinctive The Life of the Kitchen R30GIS DR30GIFS PLANNING GUIDE 30 Wide All tolerances 1 16 1 6 mm unless otherwise noted ___________ 46 3 4 118 7 cm gt e 28 9 16 72 5 cm gt me 28 71 1 cm gt lt 26 1 8 66 4 cm e 24 61 0 cm gt All Gas Ranges ARNIN Observe all governing codes and ordinances during planning and installation Contact your local building department for further information This appliance must be installed in accordance with the accompanying installation instructions Front of open door Front of handle Front of knobs Front panel Rear of front panel NOTE Models DR30GS and DR30GFS are not compatible with a raised vent e Backguard thickness 1 1 8 2 9 om gt 9 22 9 cm i Grates extend Backguard1 L 6 15 2 cm 1 above trim J Y 3 7 6cm _ backguard backguard y 1 DR30GI F S 1 3 4 4 4 cm backguard 1 4 6 4 mm say a See table for compatibility External handle shown some models DR30GIFIS 35 have integral handle lt Full stainless 88 9 cm steel side panels to 37 94 0 cm t DR30GI F S 3 1 2 8 9 cm SSS a Se ee partial stainless a a ee gg steel side panels Product width removable 29 7 8 75 9 cm OVERALL DEPTH DIMENSIONS S
7. IDE VIEW Part Number Compatibility 3 Standard on models DR30GIS DR30GIFS AERSOGLBG Low profile 13 4 inch Optional on models DR30GS DR30GFS Optional on models DR30GS DR30GFS AFRB30G03 NOT compatible with models DR30GIS DR30GIFS Standard on models DR30GS DR30GFS AERB30606 NOT compatible with models DR30GIS DR30GIFS Optional on models DR30GS DR30GFS PEBBEOEES NOT compatible with models DR30GIS DR30GIFS 1 Only backguard model AER30GLBG is compatible with a raised vent asg E AMERICAN AY OWNED M f afin Phone 800 793 0093 AVAILABLE BACKGUARDS All specifications subject to change without notice www dacor com DR3OGS DR30GFS DR3OGIS DR3SOGIFS Document PG05 007 Revised 04 04 13 Page 2 5 odacor Distinctive 30 Wide PLANNING The Life of the Kitchen All Gas Ranges GUIDE All tolerances 1 16 1 6 mm 0 unless otherwise noted m Failure to meet or exceed the maximum and minimum dimensions clearances stated may result in a fire hazard m The range should be placed away from drafts that may be caused by doors windows and heating and air conditioning outlets m To eliminate the risk of burns or fire by reaching over heated surface units cabinet storage space located above surface units should be avoided If P Coan oe Back wall cabinet storage space is to be provided directly immediately above the range the risk of personal injury may be b
8. Revised 04 04 13 Page 4 5 odacor Distinctive 30 Wide PLANNING The Life of the Kitchen All Gas Ranges GUIDE Raised Vent Self Rimming Installation Cutout Options Models DR30GIS and DR30GIFS Only All tolerances 1 16 1 6 mm 0 unless otherwise noted For all installations with a raised vent Countertop height 34 3 4 88 3 cm min 36 7 8 93 7 cm max Wall Countertop thickness 1 5 8 4 1 cm max 3 8 min 1 0 cm flat countertop overhang required behind cutout 29 1 2 74 9 cm _ NOTE For all raised vent installations use only Dacor raised vent model ERV3015 ao Stiffener 11 w KAIN fly ty Rear wall or 3 8 9 5 mm min Countertop f any Compre Dee countertop edge countertop overhang ERV3015 Back of m _ above counter both sides raised vent DROGI control panel n F S Li I i427 1 2 69 9 cm a Cabinet face Fe lm raised vent opening 1 29 1 4 74 3 cm gt ae countertop opening 7 6 cm Aa i cua i 20 5 8 side panel installe 30 76 2 cm cabinet opening 52 4 below countertop l _ 3 8 min 1 0 cm space behind raised vent chassis to clear stiffener Cabinet face _ below countertop Notch countertop overhang to width of a et ee eee cabinets Countertop overhang 1 5 8 4 1 cm max 24 24 1 4 CABINET
9. ehind range reduced by installing a range hood m In all instances installation of a range hood is highly Top of recommended The hood should project horizontally finished a minimum of five 5 inches beyond the face of counter os the cabinets See the range hood specifications for 5 minimum clearances Suggested m If installing a raised vent install only Dacor model 14 35 6 cm location of ERV3015 x gn 23 W _ utilities m The range may be installed flush to the rear wall See diagram and notes for rear wall surface requirements It is not necessary to install non P lt combustible materials behind the range below the countertop height m Any openings in the wall behind the appliance or in the floor underneath it must be sealed 30 min 36 91 4 cm recommended 37 94 0 cm 76 2 cm 30 76 2 cm min max a See the cutout dimensions on following page for self rimming installations FREESTANDING INSTALLATION CABINET CUTOUT DIMENSIONS MODELS DR30GS DR3OGFS DR30GIS AND DR30GIFS 1 30 76 2 cm min vertical clearance from top of range grates to bottom of uncovered wood or metal cabinet 24 61 cm min clearance if bottom of wood or metal cabinets are protected by not less than 1 4 0 6 cm flame retardant millboard covered with no less than No 28 MSG sheet steel 0 015 0 04 cm stainless steel or 0 024 0 06 cm aluminum or 0 020 0 0
10. m max 24 1 4 27 1 2 CABINET DEPTH CUSTOM CABINET 27 1 2 OR DEEPER PARTIAL SIDE PANELS INSTALLED TOP VIEW PARTIAL SIDE PANELS REMOVED TOP VIEW 1 To create a built in look on the front of the cabinet this dimension may be changed to 29 1 4 74 3 cm Width notches remains 30 For 24 to 24 1 4 inch deep cabinets the side panels and control panel will protrude from the cabinet face a total of 5 5 8 inches All specifications subject to change without notice www dacor com Phone 800 793 0093 DR3OGS DR30GFS DR3OGIS DR3OGIFS Revised 04 04 13 Page 5 5 Distinctive 30 Wide PLANNING Document PG05 007 dacor All Gas Ranges GUIDE The Life of the Kitchen Self Rimming Installation Standard Cutout Requirements Models DR30GIS and DR30GIFS Only 10 min 25 4 cm to any combustibles above counter both sides Non combustible rear wall required 24 3 8 min 30 a cm 61 9 cm countertop cabinet opening Cabinet face MA below countertop Countertop front STANDARD WIDTH CUTOUT FOR MODEL DR3ODI F S SELF RIMMING TRIM KIT ATKDR30GW REQUIRED Electrical Specifications Dimensions All Models E E S O lt lt aq a 12 1 4 z z 31 1 cm aaa x gt kK gt 14 1 4 6 183 cm 36 2 cm long 12 30 5 cm