Home

Dacor Stove EH42 User's Manual

image

Contents

1. eese 9 Rotating the 10 15 AHT10 Transition Kit 16 Mounting Bracket 17 Hanging the Range Hood 18 Duct Work Installation 18 Final Electrical Installation 19 Verifying Proper 21 Installation Checklist 21 Before You Begin Important e Installer In the interest of safety and to minimize prob lems read these installation instructions completely and carefully before you begin the installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the local electrical inspector s use e If you have questions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team Dacor Customer Service Team Phone 800 793 0093 U S A and Canada Monday Friday 6 00 a m to 5 00 Pacific Time Web site www Dacor com All specifications subject to change without notice Dacor assumes no liability for changes to specifications 2008 Dacor all rights reserved Important
2. Filters Make sure the main power switch is off Turn on power at the circuit breaker panel or fuse box ON Turn on the main power Switch Install the filter s 4 OFF eS 207 o TM Touch the LIGHTS feature key Verify that all the lights come on Touch the LIGHTS key again to turn the lights to the low setting Touch the LIGHTS key again to turn the lights off Touch the FAN feature key once and release Verify that one light is showing on the fan speed indicator and that the fan is on at low speed Touch and release the FAN key repeatedly three times Verify that with each touch of the key the number of lights on the fan speed indicator increases and that the fan speed increases LIGHTS TIMED CLEAN FILTER Touch the FAN key again to turn the fan off If the hood fails to operate properly Verify that power is supplied to the hood Check the electrical connections to ensure that the installation has been completed correctly Repeat the above test If the hood still does not work contact an authorized Dacor service company at 800 793 0093 Do not attempt to repair the appliance yourself Dacor is not responsible for service required to correct a faulty installation Installation Checklist WARNING To ensure a safe and proper installation the follow ing checklist should be completed by the installer to ensure that no part of the installation has
3. not ground the appliance or appliance wiring to a EH3612 EH3618 MH3612 MH3618 36 91 5 cm gas pipeline or to the neutral white power supply wire EH4212 EH4218 42 106 7 cm Do not install a fuse in the neutral or ground circuit EH4812 EH4818 MH4812 MH4818 48 121 9 ee wi P E a aes as F ard wire the hood according to local code directly to EROS ee a dedicated three wire grounded single phase circuit All tolerances 1 16 0 unless otherwise stated rated at 120 Vac 60 Hz 15 Amp 6 dacar Planning the Installation WARNING To reduce the risk of fire and to properly exhaust air be sure to duct air outside the house or building Do not vent exhaust air into spaces within walls or ceil ings or into attics crawl spaces or garages To prevent combustion by products smoke or odors from entering the home and to improve efficiency tape all duct joints securely Use only duct work constructed of materials deemed acceptable by state municipal and local codes Range hoods may interrupt the proper flow of smoke and combustion gases from furnaces gas water heaters and fireplaces To avoid drawing lethal gases into the home follow the manufacturer s recom mendation for these devices and consult NFPA and ASHRAE recommendations Failure to install a remote blower or proper duct work may result in a back draft and or the insufficient vent ing of smoke and fumes DO NOT ins
4. The customer should not install repair or replace any part of the range hood unless specifically recommended in the literature accompanying it A qualified service technician should perform all other service Contact the nearest Dacor authorized service representative at 800 793 0093 or at www Dacor com for examination repair or adjustment Use this range hood only for its intended purpose as outlined in the use and care manual Do not use this range hood to vent hazardous or explosive materials or vapors This range hood is not intended for commercial use or for use with a commercial range or cooktop Keep all packaging materials away from children Plastic bags can cause suffocation Do not use an extension cord or adapter plug with this appliance Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities The installer must show the customer the location of the fuse box or circuit breaker panel box so that the customer knows where and how to turn the power off When cutting or drilling into the wall or ceiling do not damage electrical wiring and other hidden utilities Befo
5. Remove cable clam O p Wiring Harness Remove cable ties 10 dacar 8 Disconnect the wiring harness connector from the blower motor While supporting the blower from below remove the four 4 nuts that hold the blower and mounting plate in place Remove the blower from the hood 11 Remove and discard Remove and discard the mounting plate attached to the blower motor Remove the four 4 nuts that hold the rear mounting plate in place and remove it See below Attach the mounting plate removed in step 11 rear mounting plate to the blower motor Rear Mounting Plate Installation Instructions 13 Insert the opening on the blower motor assembly into the hole inside the back of the hood The connector on the motor must be toward the bottom of the hood Attach it using four 4 nuts Connector location 14 Route the wiring harness as shown Secure the har ness to the motor assembly with the cable clamps sup plied with the hood in the positions shown below 15 Attach the wiring harness to the brace inside the hood on the right side using two 2 supplied cable ties 16 Use a cable tie to take up any remaining slack that may exist in the wiring harness Stow the harness behind the plate on the right side Securing any slack will reduce additional noise due to vibration Wiring Harness Cable IMPORTANT For proper operation route and secure the harness
6. The minimum vertical distance between the cooktop surface and the exterior part of the hood must be no less than 25 63 5 cm The vertical distance may be longer for the range or cooktop being used Consult the range or cooktop installation instructions for the minimum and maximum vertical distance from the appliance being used 2 dacor Important Safety Instructions WARNING 21 TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF ARANGE TOP GREASE FIRE a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP AFLAMING PAN you may be burned DO NOT USE WATER including wet dish cloths or towels a violent steam explosion may result Use a fire extinguisher ONLY if You have a Class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being called You can fight the fire with your back to an exit Product Specifications General Specifications All Models Load 10 0 Amp Max surge Lights 120 Vac 75 W halogen Weight Specifications EH3012 MH3012 48 Ibs 22 kg EH3018 MH3018 EH3612 MH3612 EH3618 MH3618 57 Ibs 26 kg EH4212 55 Ibs 25 kg m EH4218 60 Ibs 27 kg Model Specific EH4812 MH4812 70 Ibs 32 kg Model Number EH4818 MH4818 77 l
7. 45 7 cm 15 6 cm Model a B c D MH3612 35 7 8 91 1 cm ee MH3018 29 7 8 75 9 cm MH3618 35 7 8 91 1 cm ee MH4818 47 7 8 121 6 cm 32 34 9 cm 81 3 cm Sy Dimensions of Optional 9 AHT10 Transition vw S s For dual exhaust models See 1 9 cm page 7 for more information Parts List EN 2 temporary mounting brackets Temporary mounting hardware Hood assembly with filters size and style varies with model Blower mounting hardware used only for installations requiring rear exhaust configuration Light replacement tool Literature Light bulbs quantity varies with model STAINLESS STEEL CLEANER Dacor Stainless Steel Cleaner dacar 5 Planning the Installation WARNING Observe all governing codes and ordinances during planning and installation Contact your local building department for further information Cabinet layout See the diagram for minimum installed distance from WARNING To reduce the risk of personal injury caused by reaching the hood to the cooktop surface The minimum specified distance may be higher for the particular range or cooktop in use Check the manufacturers specifications over a hot appliance cabinet storage space located for the cooktop or range directly above the range should be avoided Carefully check the location where the hood is to be installed The hood should be placed for convenient access Make certain that e
8. Put the bracket against the wall and line up the center hole with the intersection of the bracket center lines on the wall Make sure the anchors and or screws used are strong enough to support the hood Make sure drywall installations are properly reinforced Reinforced Drywall 2n I I I I I I I I I I I I I I I I 1 2 oO Mark the two mounting hole positions through the holes in the bracket Drill the pilot holes for the screws or anchors and attach the brackets securely to the wall 17 Installation Instructions Hanging the Range Hood Duct Work Installation WARNING WARNING During duct installation make sure there are no obstructions that keep the damper flaps on the top of the hood from opening Hanging the range hood requires two people Do not attempt to lift the hood without assistance 1 Remove the plastic coating from the outside of the hood Install the duct work starting from the hood working toward the outside vent Observe the specifications on page 7 2 Remove the filter s to reduce weight and avoid dam age Fasten all joints with sheet metal screws and seal with 3 Lift the hood up on both sides and slip the mounting ducbiape oF centtied lt ivertane slots over the tabs on the mounting brackets 4 Lift the hood into its final position and mark the desired locations for the anchors or wood screws through the mounting slots on the ba
9. exactly as shown Cable tie if necessary 17 Tip the hood back down so that the top of the hood faces up Using existing screws attach the cover plate removed in step 3 to the top of the hood to cover the hole 18 Attach the duct collar removed in step 2 to the back of the unit using four 4 existing screws Rotating the Blower for Models EH4812 and MH4812 Models that are 12 inches high equipped with two blowers 1 Place the hood assembly on a large flat surface 1 2 Remove and save the screws and the two 2 duct col lars from the top of the unit See below 3 Remove and save the screws and the two 2 cover plates that cover the holes on the back of the hood Cover Plate n dscor 11 Installation Instructions 4 Tip the hood back so that it lays on its back with the front pointing up Remove the filters from the under side of the hood Locate the wiring harness Cut the cable tie that takes up the slack in the cable It is located behind the panel on the right side inside the hood Also cut the two 2 cable ties that hold the wiring harness to the brace inside the hood on the right side See below 7 Remove and save all the nuts that hold the wiring har ness cable clamps in place Remove and save the clamps Remove cable Wiring Harness Remove cable ties 8 Disconnect both wiring harness connectors from the blower motors 9 While supporting each blower from below remov
10. not use flexible metal duct Do not use duct work that is smaller in cross sectional area than the recommended types above 7 Preparing for Installation Verify the Package Contents Unpack the parts box and verify that all parts have been included according to the parts list on page 5 If any item is missing or damaged please contact the dealer immedi ately Do not install a damaged or incomplete appliance Make sure you have everything necessary for proper instal lation before proceeding Mounting Location Preparation WARNING The electrical service to the range hood should be installed only by a licensed electrician Observe all governing codes and ordinances during site preparation and installation Contact your local building department for further information Failure to properly anchor the hood to the wall may result in personal injury due to the unit falling off the wall To avoid an electric shock hazard and property dam age locate electric wires and water pipes and avoid drilling or cutting in the vicinity Use the temporary mounting brackets only to hold the hood in place until permanent anchoring is installed Temporary mounting brackets and the screws and anchors to hold them in place during installation are provided with the hood Two anchors and screws are used per bracket Determine the number size and type of anchors required to attach the hood permanently to the wall and o
11. the top of the hood to cover the holes 18 Attach the duct collars removed in step 2 to the back of the unit using the existing screws Rotating the Blower for Models EH3018 MH3018 EH3618 MH3618 EH4218 Models that are 18 inches high equipped with a single blower Place the hood assembly on a large flat surface 2 Remove and save the four 4 screws and the duct col lar from the top of the unit 3 Remove and save the four 4 screws and the cover plate that covers the hole on the back of the hood Duct Collar Cover Plate 4 Tip the hood back so that it lays on its back with the front pointing up Remove the filters from the under side of the hood Locate the wiring harness Cut the cable tie that takes up the slack in the cable It is located behind the panel on the right side inside the hood Also cut the two 2 cable ties that hold the wiring harness to the brace inside the hood on the right side 7 Remove and save the nut that holds the wiring harness cable clamp in place Remove and save the clamp Remove cable clam O p Wiring Harness Remove cable ties dacor 13 Installation Instructions 8 Disconnect the wiring harness connector from the 11 Route the wiring harness as shown Secure the har blower motor ness to the motor assembly with the cable clamps sup plied with the hood in the positions shown below 9 While supporting the blower from below remove the four 4 nuts t
12. Safety Instructions Important Information About Safety Symbols and Labels Safety Instructions DANGER Important Safety Instructions and warnings in Immediate hazards that WILL result in severe personal these instructions are not meant to cover all possible injury or death problems and conditions that can occur Use common sense and caution when installing maintaining or oper wmNNe ating this or any other appliance WARNING Always contact the Dacor Customer Service Team Hazards or unsafe practices that COULD result in severe about problems and conditions that you don t under personal injury or death stand CAUTION Hazards or unsafe practices that COULD result in minor personal injury or property damage DANGER To avoid the possibility of explosion or fire do not store or use combustible flammable or explosive vapors and liquids such as gasoline inside or in the vicinity of this or any other appliance Also keep items that could explode such as aerosol cans away from cooktop burners ovens and range hoods Do not store flammable or explosive materials in adjacent cabinets or areas WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the ma
13. ack will reduce additional noise due to vibration Cable Clamps Wiring Harness IMPORTANT For proper operation route and secure the harness exactly as shown Cable tie if necessary 14 Tip the hood back down so that the top of the hood faces up Using existing screws attach the cover plates removed in step 3 to the top of the hood to cover the holes 15 Attach the duct collars removed in step 2 to the back of the unit using the existing screws 16 dacar AHT10 Transition Kit Installation On dual exhaust models the two 8 exhausts may be merged into one 10 duct using Dacor transition kit AHT10 Install the transition before installing the hood on the wall It connects to the hood on the top or rear depending on the type of installation Preparing the AHT10 for Installation Prepare the transition for installation by bending the bot tom edges at right angles to create a flange around the base IMPORTANT On 12 high hoods modified to exhaust out the rear leave one of the long edges unbent 82 Leave this edge unmodified bend up other three Transition Flange Prep 12 high models with rear exhaust Transition Flange Prep models using top exhaust and 18 high models with rear exhaust Drill pilot holes around the edges of the mounting flange including the unmodified edge if the transition will be mounted to the back of a 12 high hood see above Installing the AHT10 Tran
14. been over looked Proper installation is the responsibility of the hom eowner The importance of proper installation of your Dacor range hood cannot be overemphasized Is the hood properly attached to the wall according to the instructions on page 16 and 17 Is the duct work completely installed Are all joints attached with sheet metal screws and wrapped with duct tape See page 18 Is the range hood wired and grounded according to these instructions and in accordance with all applicable electric codes See page 18 Are the filters properly installed according to the use and care manual Has proper operation been verified Have any problems been noted on the warranty card or during the on line warranty activation Has the war ranty been activated on line or the warranty card filled out completely and mailed dscor 21 cdacor The Life of the Kitchen Dacor e 1440 Bridge Gate Drive Diamond Bar CA 91765 e Tel 800 793 0093 e FAX 626 403 3130 e www Dacor com
15. bs 35 kg EH48 MH48 EH42 EH30 MH30 EH5418 84 Ibs 38 kg EH54 EH36 MH36 ues e Exhaust Outputs Fan Rating 1200 CFM 600 CFM 600 CFM dacar 3 Product Specifications Dimensions Tolerances 1 16 0 1 6 mm 0 unless otherwise stated NOTE The exhaust duct s and electrical wiring can be connected from either the top or the back of the hood Single exhaust models Dual exhaust models Standard 8 duct connection Standard 8 duct connection Front of Electrical access holes 7 8 Dia 5 1 cm 6 1 8 15 6 cm 1 3 8 cm 4 10 2 cm 3 7 6 cm 50 2 c 2 cm Top Dimensions 355 3 76 em ae Electrical access holes 7 8 Dia 5 1 cm Dual exhaust models Single exhaust models Bottom of Standard 8 duct connection Standard 8 duct connection hood Back Dimensions Models EH48 MH48 EH54 All other models See facing page 4 dacar Product Specifications EH3012 29 7 8 75 9 cm EH3612 35 7 8 91 1 cm 26 7 8 EH4212 41 7 8 106 4 cm 68 3 EH4812 47 7 8 121 6 cm aia cay d on 4812 47 7 8 121 6 cm OVERALL DIMENSIONS 68 MH3012 29 7 8 75 9 cm n 64 EH3018 29 7 8 75 9 cm EH3618 35 7 8 91 1 cm 26 7 8 EH4218 41 7 8 106 4 om Overall EH4818 47 7 8 121 6 cm 18 6 1 8 Dimensions EH5418 53 7 8 136 8 cm
16. ck and top of the hood Remove the hood from the wall 6 Drill the pilot or mounting anchor holes If using mount ing anchors insert them into the mounting holes Mounting Hole Locations Reattach the hood to the temporary mounting brackets Lift the hood into its final position and fasten it in place Insert the fasteners through the mounting slots in the back and top of the hood into the studs mounting blocks or anchors 18 dacar Installation Instructions Final Electrical Installation WARNING To avoid electric shock or fire hazard prior to connecting the electrical wiring to the hood make sure that power to the hood power supply line is turned off at the fuse box or circuit breaker panel Improper connection of the hood electrical wiring may create an electric shock or fire hazard and may result in dam age to the hood s electrical system See page 6 for specifications Do not ground the hood to the neutral white power supply wire Connect the hood ground wire to a separate prop erly grounded wire installed by a licensed electrician Make sure all wire used is capable of handling the total connected load See page 3 1 Turn off power to the hood electrical circuit at the circuit 3 Connect the hood wiring to an electrical junction box breaker or fuse box on a dedicated circuit See page 6 for specifications Connect it according to the wiring diagram below or on the following page 2 Feed the wiring th
17. clacar MANOS EK TE Installation Instructions Epicure and Millennia Wall Mount Range Hoods For use with models EH30 EH36 EHA2 EH48 EH54 MH30 MH36 and MH48 APPROVED FOR USE WITH ALL DACOR RANGES AND COOKTOPS TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI UL 507 STANDARD FOR ELECTRIC FANS AND CAN CSA C22 2 NO 113 STANDARD FOR FANS AND VENTILATORS Part No 102139 Rev E Important Safety Instructions sees 1 Important Information About Safety Instructions 1 General Safety 2 Product Specifications esses 3 General 3 Dirmienslons 0 ne t eig ere be cte ee ade e nva Haee 4 Product Specifications esses 5 Parts Bn 5 Planning the Installation eeeeeeesess 6 Cabinet enne 6 Power Supply e eot ds 6 Table of Contents Preparing for 8 Verify the Package 8 Mounting Location Preparation 8 Electrical Service Installation 8 Duct Cutout i eb ect RI Se 8 Installation Instructions
18. e the four 4 nuts that hold the blower and mounting plates in place Remove both blowers from the hood 12 dacar Remove and discard 10 Remove and discard the mounting plates attached to both blow er motors 11 Remove the nuts that hold the rear mount ing plates in place and remove See below 12 Attach the mounting plates removed in step 11 rear mounting plate to the blower motors 13 Insert the opening of each blower motor assembly into the holes inside the back of the hood The connector on the motors must be toward the bottom of the hood Attach them with four 4 nuts each Connector locations Installation Instructions 14 Route the wiring harness as shown below Secure the harness to the motor assemblies using the cable clamps supplied with the hood in the positions shown 15 Attach the wiring harness to the brace inside the hood on the right side using two 2 supplied cable ties 16 Use a cable tie to take up any remaining slack that may exist in the wiring harness Stow the harness behind the plate on the right side Securing any slack will reduce additional noise due to vibration Cable Clamps Wiring Harness IMPORTANT For proper operation route and secure the harness exactly as shown Cable tie if necessary 17 Tip the hood back down so that the top of the hood faces up Using existing screws attach the cover plates removed in step 3 to
19. enter line of the cooktop or range The line will be used to line up the mounting brackets during installa tion 2 Locate the center lines for the duct cutout s according to the dimensions on page 4 For installations venting through the top of the hood use the top dimensions to locate the center lines on the ceiling or cabinet bottom For installations venting through the back of the hood use the back dimensions to locate the center lines on the back wall See the diagrams on the right 3 Cuta hole for the duct to pass through 11 28 cm in diameter Center it on the center lines Dual exhaust models require two 2 holes Preparing for Installation EM Back wall Ceiling or cabinet bottom Duct Cut Out for Rear Venting Duct Cut Out for Top Venting Installation Instructions WARNING Blower Rotation Instructions MODEL SEE PAGE EH3012 MH3012 EH3612 MH3612 10 EH4212 Do not install the range hood unless the electrical service provided meets the range hood specifica tions Observe all governing codes and ordinances during EH4812 MH4812 an 11 EH3018 MH3018 EH3618 MH3618 13 4218 4818 4818 5418 installation Contact your local building department for further information A qualified technician must complete the installa tion of this built in appliance More than one person is required to raise the hood into place The owner is responsible to make sure the hood is properly
20. f duct used See the chart below X 10 rectangular For each elbow and transition added to the duct work a certain number of feet must be subtracted from the maxi mum duct run to compensate for wind resistance To deter mine the length the duct work cannot exceed subtract all of the equivalent lengths of the elbows and transitions listed below from the maximum duct run above Duct Work Equivalent Lengths EQUIVALENT LENGTHS 374 X 10 3 X 10 to to round 90 25 feet 8 10 round 4 feet transition transition damper The equivalent lengths of roof and wall caps vary with model and configuration For equivalent length contact the manufacturer or a qualified HVAC specialist Duct Work Design Tips Wherever possible reduce the number of transitions and turns to as few sharp angles as possible Two staggered 45 angles are better than one 90 Keep turns as far away from the hood exhaust as possible and as much space between bends as possible For best performance use round duct instead of rectangu lar especially when elbows are required If multiple elbows are used try to keep a minimum of 24 straight duct between them Avoid S or back to back use of adjacent elbows In regions where the weather gets extremely cold use ther mal breaks such as a short section of non metallic duct to avoid indoor heat loss Locate the break as close as pos sible to the outside pass through point Do
21. hat hold the blower in place Remove the 12 Attach the wiring harness to the brace inside the hood blower from the hood on the right side using two 2 supplied cable ties 13 Use a cable tie to take up any remaining slack that may exist in the wiring harness Stow the harness behind the plate on the right side Securing any slack will reduce additional noise due to vibration Wiring Harness 10 Insert the opening on the blower motor into the hole inside the back of the hood The connector on the motor must be toward the bottom of the hood Attach it using four 4 nuts IMPORTANT For proper operation route and secure Cable tie if the harness exactly as shown necessary 14 Tip the hood back down so that the top of the hood faces up Using four 4 existing screws attach the cover plate removed in step 3 to the top of the hood to cover the hole 15 Attach the duct collar removed in step 2 to the back of the unit using the four 4 existing screws Connector location 14 dacar Installation Instructions Rotating the Blower for Models EH4818 MH4818 and EH5418 Models that are 18 inches high equipped with two blowers 1 Place the hood assembly on a large flat surface 2 Remove and save the screws and the two 2 duct col lars from the top of the unit 3 Remove and save the screws and the two 2 cover plates that cover the holes on the back of the hood Duct Collar 4 Tip the hood bac
22. installed 1 Start by removing the filters from the bottom of the hood Put them in a safe location so that they will not be damaged 2 If the hood will be installed in a top exhaust configura tion skip to page 16 If the hood will be installed so that air will exhaust out of the back the blowers must be rotated into the correct position before hanging the hood The procedure for rotating the blower depends on the hood model number See the table at the right 9 Installation Instructions Rotating the Blower for Models EH3012 MH3012 EH3612 MH3612 and EH4212 Models that are 12 inches high equipped with a single blower 1 2 Place the hood assembly on a large flat surface Remove and save the four 4 screws and the duct col lar from the top of the unit See below Remove and save the four 4 screws and the cover plate that covers the hole on the back of the hood Duct Collar Cover Plate Tip the hood back so that it lays on its back with the front pointing up Remove the filters from the under side of the hood Locate the wiring harness Cut the cable tie that takes up the slack in the cable It is located behind the panel on the right side inside the hood Also cut the two 2 cable ties that hold the wiring harness to the brace inside the hood on the right side See below Remove and save the nut that holds the wiring harness cable clamp in place Remove and save the clamp
23. k so that it lays on its back with the front pointing up Remove the filters from the under side of the hood Locate the wiring harness Cut the cable tie that takes up the slack in the cable It is located behind the panel on the right side inside the hood Also cut the two 2 cable ties that hold the wiring harness to the brace inside the hood on the right side 7 Remove and save all the nuts that hold the wiring har ness cable clamps in place Remove and save the clamps Remove cable clamps Wiring Harness Remove cable ties 8 Disconnect both wiring harness connectors from the blower motors 9 While supporting each blower from below remove the four 4 nuts that hold each blower in place Remove both blowers from the hood 10 Insert the opening of each blower motor into the holes inside the back of the hood The connector on the motors must be toward the bottom of the hood Attach them with four 4 nuts each locations 15 Installation Instructions 11 Route the wiring harness as shown Secure the har ness to the motor assemblies using the cable clamps supplied with the hood in the positions shown below 12 Attach the wiring harness to the brace inside the hood on the right side using two 2 supplied cable ties 13 Use a cable tie to take up any remaining slack that may exist in the wiring harness Stow the harness behind the plate on the right side Securing any sl
24. lectric power can be provid ET ed in the selected location The hood must be centered horizontally over the cooktop range The hood model selected must be as wide as the cooktop surface or wider Plan the installation so that all minimum dimensions are met or exceeded Dimensions shown provide minimum clearances unless otherwise noted Electrical Access All contact surfaces between the hood and any cabi nets or walls must be solid and at right angles e Install the range hood and cooking appliance s so that they can be removed if service is required Power Supply WARNING The electric service to the range hood should be installed only by a licensed electrician It is the owner s responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician The electrical installation including minimum supply wire size and grounding must be in accordance with the National Electric code ANSI NFPA or latest revi sion and local codes and ordinances A copy of this standard may be obtained from National Fire Protection Association 1 Batterymarch Park Quincy Massachusetts 02269 9101 ground terminal on the hood must be connected MINIMUM CABINET WIDTH to a grounded metallic permanent wiring system or Models grounding conductor installed by a licensed electrician EH3012 EH3018 MH3012 MH3018 30 76 2
25. nufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel READ AND SAVE THESE INSTRUCTIONS dacar 1 Important Safety Instructions General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance follow basic safety precautions including the following WARNING Do not install or operate this hood if it has been damaged dropped has damaged electrical wires or is not working properly If the product is damaged when received immediately contact the dealer or builder This range hood must be installed and grounded by a qualified installer according to these installation instructions All installation work and electrical wiring must be performed in accordance with all applicable codes and standards including fire rated construction A minimum of two people are required to safely install this appliance Install or locate this appliance only in accordance with these installation instructions and the requirements specified by the manufacturer of the cooktop or range Improper installation adjustment alteration service or maintenance can cause serious personal injury or property damage
26. r the cabinets based on the type of installa tion and the weight chart on page 3 Make sure the mount ing surface is properly reinforced to handle the full weight of the hood If mounting the unit to a drywall or plastered sur face install a reinforced mounting block between the studs behind all hood mounting locations You may attach screws directly to the studs and cabinets if they line up with the mounting holes in the back and top of the hood If mounting the hood to brick or masonry select anchors capable of holding the full weight of the hood 8 dacar Electrical Service Installation WARNING The electric service to the range hood should be installed only by a licensed electrician Install a junction box in the vicinity of the hood electri cal access holes according to local codes Install it either behind or above the hood The diagram below shows sug gested locations Drill 7 8 holes in the wall or cabinet as necessary to allow the wiring to pass through into the hood See page 4 for hole locations Suggested Electrical Location le 9 Location Duct Cutout 1 Using a pencil draw the vertical center line for the range hood on the wall Extend the line down 10 25 4 cm from where the top of the hood will be located The center line for the hood is usually halfway between the cabinets at the installation location or the same as the c
27. re installing or servicing the range hood switch power off at the fuse box circuit breaker and lock the electrical panel door to prevent power from being switched on accidentally When the electrical panel cannot be locked securely fasten a prominent warning device such as a tag to the electrical panel Read the use and care manual completely before using the appliance Clean the appliance only as instructed in the use and care manual Use only the cleaners specified Do not tamper with the controls Never allow the filter s to become blocked or clogged Do not allow foreign objects such as cigarettes or napkins to be sucked into the hood Clean the filter s and all grease laden surfaces often to prevent grease fires and maintain performance If the cooktop and range hood are near a window use an appropriate window treatment Avoid long drapes or other window coverings that could blow over the cooktop and hood resulting in a fire hazard Always run the fan s whenever the cooktop is operating Never leave the range or cooktop unattended when a burner or element is in use Boil overs and greasy spills may smoke and or ignite Do not leave children alone or unattended in the area where the cooktop and range hood are in use Never allow children to sit or stand on an appliance Do not let children play with a range cooktop or range hood Do not store items of interest to children above or around the cooktop range or range hood
28. rough the wiring access holes in the hood Connect the wiring to the terminal block inside the hood as shown To house circuit breaker panel or fuse box Junction Box Wire Nut 3 places X GREEN E Back UL CSA approved a NEMA strain relief hia hood Neutral White Ground Green ae Hot Black 3 Wire Connection to Junction Box To junction box Hood Power Terminals dacor 19 Installation Instructions WARNING Do not ground the circuit to a gas line Do not ground the circuit to a hot water pipe Water lines that are insulated must be jumped to assure continuity to ground See below To house circuit breaker panel or fuse box N Separate No 10 minimum Pa copper ground wire Wire Nut 3 places Meter Fasten clamp tightly on pipe No 4 copper wire his Junction Box UL CSA approved NEMA strain relief To range hood Insulated Pipe Jumper if necessary Grounding the Hood Wiring Using an External Cold Water Pipe Light Bulb Installation FTN 1 Attach the included suction cup to one of the provided light bulbs Insert it into one of the light fixtures Screw it into place and remove the suction cup Repeat for the remaining light fixtures 20 dacar Installation Instructions Verifying Proper Operation 9 Main Power Switch lA Feature E
29. sition Top exhaust models and 18 high models with rear exhaust Center the transition over the duct collars and fasten it in place using sheet metal screws not included Seal the base of the transition with duct tape Top mounting shown Installation Instructions 12 high models with rear exhaust Center the transition over the duct collars while resting the unmodified edge on the top of the hood Fasten in place using sheet metal screws not included Seal the base of of the transition with duct tape Mounting Bracket Installation 1 Draw the horizontal center line for the temporary mounting brackets on the wall The center line for the brackets is 2 1 8 54 cm below where the top of the hood will be located The horizontal line marks the cen ter line of the mounting screws that hold the temporary mounting brackets in place IMPORTANT Installing the brackets lower or higher than the center line shown will cause alignment problems during final installation Draw the two 2 vertical center lines for the brackets on the wall They are located on both sides of the hood center line drawn on the wall before making the duct cut out The distance from the center line depends on the model See the chart below TEMPORARY BRACKET CENTER LINE DISTANCE 12 3 8 31 4 cm Models Bracket location Bracket location location 3 4 Find the temporary mounting bracket in the shipping box
30. tall an additional in line or external blow er to increase the length of the duct run Even small differences between blower air flow rates can greatly reduce the air draw by the hood All duct work materials including screws and duct tape must be purchased separately by the customer When planning new duct work always look for the shortest most direct route to the outside The blower assembly can be rotated to accommodate venting and wiring through the top EM or the back El Af f A fed The hood exhaust connects to an 8 inch round duct You can increase the duct size over the duct run if desired To prevent a back draft never decrease the duct size over the run If existing duct work is smaller than 8 inches in diameter remove it and replace it with 8 inch duct work Do not rely on tape alone to seal duct joints Fasten all connections with sheet metal screws and tape all joints with certified silver tape or duct tape Use sheet metal screws as require to support the duct weight e To prevent back drafts a damper at the duct outlet may also be required Make sure duct work does not interfere with floor joists or wall studs On dual exhaust models the two 8 exhausts may be merged into one 10 duct using Dacor transition kit AHT10 See page 16 for details Calculating the Maximum Duct Run Length The maximum straight duct length for the hood is deter mined by the type o