Home
Cyclades PM IPDU User's Manual
Contents
1. RJ 45 to DB 9F z 5 Local Se Workstation o RJ 45 Cable mm Bm Cyclades PM IPDU IN Port CSI mm times 10 20 30 40 50 518800 00 00 00 00 MlerPath Q Ci y Ci cyclades Figure 2 5 Connecting a Local Work Station to the Cyclades PM IPDU To access the console Perform the following steps to connect a computer to the console port of the PM IPDU This procedure assumes that you know how to use a terminal emulation program On a PC ensure that HyperTerminal or another terminal emulation program is installed on the Windows operating system On a computer running a UNIX based operating system such as Solaris or Linux make sure that a compatible terminal emulator such as Kermit or Minicom is installed Connect an RJ 45 serial cable to the IN port on the PM IPDU 2 Connect the other end of the RJ 45 serial cable to the RJ 45 to DB 9F straight through adaptor shipped with the PM IPDU 3 Connect the adaptor to a DB 9 serial port on a computer You may need to use a USB serial adaptor in order to connect to the computer 5 Using a terminal emulation program installed on a computer start a session The terminal should be set to ANSI emulation 9600 bps 8 bits no parity Istop bit and no flo
2. I AE 1 PMIPDU 1 DEE gt E Mr sE Ejea vi DITE TD TE TD TOR vipi ae AlterPath OnSite PM IPDU 2 ET iii ai D D D E de Q AL i i i LUS UE AAA 0 I PM IPDU 4 Casitas ac 7 i Additional Cyclades PM IPDUs with up to a total of 128 outlets Server Switch can be daisy chained Figure 1 3 The Cyclades PM IPDU with a Cyclades Management Device An integrated environment offers the following advantages e IT professionals may power down power up and reboot network devices using the same console management session from any location via telnet Secure Shell SSHv2 or through a secure web session This may all be done without the need for physical access to the hardware e Ethernet connection is available through the Cyclades management products to which the Cyclades PM IPDU is connected When used with Cyclades management products the Cyclades PM IPDU allows you via a configurable hotkey to reboot servers without leaving your telnet ssh session e The Cyclades PM IPDU inherits the security of the console server to
3. AlterPath PMIO Brackets Figure 2 3 PM10 IPDU with Mounting Brackets Installed 4 Use a Phillips screwdriver to tighten the screws 5 Use the mounting hardware recommended for your rack to mount the PM IPDU on a rack as illustrated in the following graphic Chapter 2 Installation 19 NOTE The suggested minimum screw size for wall mounting the Cyclades PM IPDUs is 10 4 8 mm or 0 19 in or 3 16 in or larger The RJ 45 cable included in the Cyclades PM IPDU package is minimum flame rated VW 1 or FT 1 and has a maximum length of 10 feet 3 meters PM8i IPDU PM10 IPDU or PM10i IPDU Cyclades ACS Console Server Cyclades TS Terminal Server Cyclades KVM Switch or Cyclades OnSite Appliance Ethernet UNIX server Figure 2 4 Rack Mount for the Cyclades PM8i IPDU PM10 IPDU or PM10i IPDU Daisy Chaining PM IPDUs You may manage a maximum of 128 outlets from a single work station by connecting slave PM IPDUs to the master PM IPDU device See Making a Direct Connection for Console Access on page 20 for more details To daisy chain a PM IPDU This procedure assumes that a master PM IPDU is already connected to a work station or to a Cyclades console server terminal server KVM switch or OnSite appliance 1 Connect one end of an RJ 45 cable to the OUT port of the main Cyclades PM IPDU which is connected to a work station or to a Cyclades c
4. Additional Cyclades PM IPDUs with up to a total of 128 outlets server Switch can be daisy chained Figure 1 2 Daisy Chained Configuration NOTE The previous graphic displays the PM IPDU being connected to the local work station with the RJ 45 to DB 9F adaptor that is shipped with the product If your work station does not have a DB 9M COM port you may need to use a USB serial adaptor in order to connect to the computer s USB port The PM IPDUs in the previous graphic are configured to be used independently of any other hardware such as the Cyclades ACS console server or Cyclades TS terminal server Integrated configuration In an integrated configuration the Cyclades PM IPDU is configured to work in conjunction with one of the following Cyclades management products e Cyclades TS terminal server e Cyclades ACS console server e Cyclades OnSite appliance e Cyclades KVM switch family A user connects to the Cyclades PM IPDU by accessing the appropriate console port of the Cyclades management product In this scenario software configuration on and monitoring of the Cyclades PM IPDU is done through the Cyclades management product and not on the PM IPDU Chapter 1 Introduction 5 itself Visit http www cyclades com support downloads php to find setup and configuration instructions for the Cyclades management products Power Source oo pol gol joe po n n
5. e 48 Off 2i o tet eU eet e de E rs 49 OW seil duo aii cde SR e DR C CRP PR ERR E UR ER NUR e IRE TI ONE FREQ AERA ES 50 DASSW 50 TOD OO lose ever G 51 AD tte 53 SAVE i PEER ER dedo I PRE SEE T 23 NU LA A A is 54 OU AA A E E IA nt eee int tte ttes 55 Ie mperatures foes era ito te etn it 56 UNAS E 57 UI RE RAR REA DEPARO 57 Upgrade aie tet RU anioni quete nin e ee etit 58 VER EE 59 up hu En 60 WHO AMI cas vasa ose a e a a e EE RR ADEL TQ oa aah 61 pgs ID 63 Appendix A Specifications iode aii ied 63 Appendix B Safety Instructions ses 73 Appendix C Circuit Breakers iii 79 vi Cyclades PM IPDU Installer Administrator User Guide vii DIN Figure 1 1 Standalone Configuration ss 3 Figure 1 2 Daisy Chained Configuration ss 4 Figure 1 3 The Cyclades PM IPDU with a Cyclades Management Device 5 Figure 1 4 Cyclades EMS IPDU n Ret AH e d ete 7 Figure 1 5 Cyclades PM8i IPDU i amp Figure 1 6 Cyclades PMIOTIPDU ignara cli ie ete eb tee EE eee tete amp Figure 1 7 Back of the Cyclades PMIOiIPDU een 9 Figure 1 8 Front of the Cyclades PM IOiIPDU een 9 Figure 1 9 T
6. 1 Log in to the PM IPDU 2 Enter the factory default username password admin pm8 A maximum of eight characters not case sensitive is allowed 3 Enter the passwd command 4 Enter a new password when prompted To create users with the adduser command 1 Login to the PM IPDU 2 Enter the adduser command followed by the new username 3 Enter the password when prompted To assign outlets to users with the assign command 1 Login to the PM IPDU 2 Enter the assign command followed by the outlet number s and username Example pm gt assign 2 jane Outlet 2 assigned to jane To name the outlets with the name command 1 Login to the PM IPDU 2 Enter the name command followed by the outlet number and desired name of the outlet Example pm gt name 2 chispa 2 Outlet now named chispa Chapter 3 Configuration 25 To save the configuration with the save command 1 2 Login to the PM IPDU Enter the save command to save the configuration Resetting the Admin Password In the event the administrator wants to reset the password for the Cyclades PM IPDU for example if the administrator forgets the admin password then the loopback connector that is shipped with the Cyclades PM IPDU may be used for temporary access to the PM IPDU To reset the admin password using the loopback connector 1 If you are not logged out log out by entering exit You must be at the login prompt for this to work
7. See the following section for a list of power cables shipped with specific PM IPDU models Modular input power cables for the PM IPDU If your PM IPDU model does not have a fixed power input cable it may ship with one of the modular cables listed in the following sections Depending on your site s location the modular input power cables included in the box vary See the following sections to find the input cable that should ship with your PM IPDU product e PMS amp i 10A IPDU and PM10i 10A IPDU power cables on page 15 e PMIOi 15A IPDU power cables on page 16 e PMI0i 16A IPDU and PM 20i 16A IPDU power cables on page 16 NOTE The Cyclades PM 10i 32Au IPDU ships with an unterminated power cord If necessary your Cyclades representative may provide guidelines on approved power plug installation Chapter 2 Installation 15 PM8i 10A IPDU and PM10i 10A IPDU power cables Table 2 2 PM8i 10A IPDU and PM10i 10A IPDU Power Cables P N Country Region CAB0089 US CAB0055 Australia and New Zealand CAB0087 Continental Europe CAB0088 United Kingdom and Ireland 16 Cyclades PM IPDU Installer Administrator User Guide PM10i 15A IPDU power cables Table 2 3 PM10i 15A IPDU Power Cables P N Country Region CABO191 US PM10i 16A IPDU and PM 20i 16A IPDU power cables Table 2 4 PM10i 16A IPDU and PM 20i 16A IPDU Power Cables P N Country Region CAB0193 Continental Europe CAB0192 Australia and New Z
8. 200 5 30 seconds 300 1 8 10 seconds 400 0 9 5 seconds 500 0 5 3 3 seconds 600 0 38 2 3 seconds 800 0 2 1 3 seconds 1000 0 15 0 9 seconds 84 Cyclades PM IPDU Installer Administrator User Guide 85 CO A AC power 20 adduser 33 adduser command 24 admin logging in as 22 admin password 25 alarm 34 alarms and monitoring 1 AlterPath PM components 7 models 7 user interface 31 assign command 24 34 assigning outlets to users 24 Australia 15 16 brackets mounting 14 buzzer status command 35 C cables PM10i 10A 15 changing the default password 24 circuit breaker PM units with one 79 trip time 83 circuit breakers PM10i L30A 80 PM10 L30A 80 PM20i L30A 82 PM20 L30A 81 command line interface 31 commands 32 configuration default parameters 23 initial 24 integrated 4 restoring the 53 saving 25 53 standalone 2 3 console 20 21 accessing the 21 logging in through the 22 console access direct 6 through a management device 6 Continental Europe 15 16 creating users 24 current command 35 currentprotection command 36 currseg command 37 Cyclades management device 5 cycle command 38 D daisy chain overview 3 4 daisy chaining PMs 2 19 DB 9 serial port 21 default configuration parameters 23 default password 22 deleting users accounts 39 86 Cyclades PM Installer Administrator User Guide deluser command 39 E electrical and hardware specifications 63 equipment requir
9. de rated to 8A Environmental Operating Temperature 32 122 F 0 50 C Relative Humidity 5 95 Mechanical Weight 12 Ib 5 45 kg Physical Dimensions W x D x H 17 x 11 5 x 1 75 in 43 18x 29 21 x 4 45 cm Table A 13 PM20 20A IPDU and PM20 L20A IPDU Specifications Characteristics Specifications Electrical Input Voltage 100 125 VAC Max Output Current Total 20A de rated to 16A Max Output Current Each Outlet 15A de rated to 12A Environmental Operating Temperature 50 122 F 10 50 C Relative Humidity 5 95 Mechanical Weight 17 lb 7 73 kg Physical Dimensions W x D x H 1 8 x 2 2 x 66 in 4 6 x 5 59 x 167 6 cm 70 Cyclades PM IPDU Installer Administrator User Guide Table A 14 PM20 L30A IPDU Specifications Characteristics Specifications Electrical Input Voltage 100 125 VAC Max Output Current Total 30A de rated to 24A Max Output Current Each Outlet 15A de rated to 12A Environmental Operating Temperature 50 122 F 10 50 C Relative Humidity 5 95 Mechanical Weight 17 lb 7 73 kg Physical Dimensions W x D x H 1 8 x 2 2 x 66 in 4 6 x 5 59 x 167 6 cm Table A 15 PM20i 16A IPDU Specifications Characteristics Specifications Electrical Input Voltage 100 240VAC Max Output Current Total 16A Max Output Current Each Outlet 10A Environmental Operating Temperature
10. 32 122 F 0 50 C Relative Humidity 5 95 Mechanical Weight 17 lb 7 73 kg Physical Dimensions W x D x H 2 0 x 2 8 x 66 in 5 18 x 7 11 x 167 6 cm Appendices 71 Table A 16 PM20i 20A IPDU and PM20i L20A IPDU Electrical Specifications Characteristics Specifications Electrical Input Voltage 100 240 VAC Max Output Current Total 20A de rated to 16A Max Output Current Each Outlet 10A de rated to 8A Environmental Operating Temperature 32 122 F 0 50 C Relative Humidity 5 95 Mechanical Weight 17 Ib 7 73 kg Physical Dimensions W x D x H 2 0 x 2 8 x 66 in 5 18 x 7 11 x 167 6 cm Table A 17 PM20i L30A Specifications Characteristics Specifications Electrical Input Voltage 100 240 VAC Max Output Current Total 30A de rated to 24A Max Output Current Each Outlet 10A de rated to 8A Environmental Operating Temperature 32 122 F 0 50 C Relative Humidity 5 95 Mechanical Weight 17 lb 7 73 kg Physical Dimensions W x D x H 2 0 x 2 8 x 66 in 5 18 x 7 11 x 167 6 cm 72 Cyclades PM IPDU Installer Administrator User Guide Table A 18 PM20i 32A IPDU and PM20i 32Au IPDU Specifications Characteristics Specifications Electrical Input Voltage 100 240 VAC Max Output Current Total 32A Max Output Current Each Outlet 10A Environmental Operating Temperature 50 122 F 10 50 C Rel
11. 57 x 5 6 x 95 5 cm Table A 3 PM8i 10A IPDU Specifications Characteristics Specifications Electrical Input Voltage 100 240 VAC Max Output Current Total 10A Max Output Current Each Outlet 10A Environmental Operating Temperature 50 122 F 10 50 C Relative Humidity 5 95 Mechanical Weight 5 Ib 2 3 kg Physical Dimensions W x D x H 17 x 3 7 x 2 63 in 43 2 x 9 4 x 6 7 cm Table A 4 PM10 15A IPDU Specifications Appendices 65 Characteristics Specifications Electrical Input Voltage 100 125 VAC Max Output Current Total 15A de rated to 12A Environmental Max Output Current Each Outlet 15A de rated to 12A Operating Temperature 50 122 F 10 50 C Relative Humidity 5 95 Mechanical Weight 8 lb 3 64 kg Physical Dimensions W x D x H 17 x 8 x 1 75 in 43 18x 20 32 x 4 45 cm Table A 5 PM10 20A IPDU and PM10 L20A IPDU Specifications Characteristics Specifications Electrical Input Voltage 100 125 VAC Max Output Current Total 20A de rated to 16A Max Output Current Each Outlet 15A de rated to 12A Environmental Operating Temperature 50 122 F 10 50 C Relative Humidity 5 95 Mechanical Weight 8 lb 3 64 kg Physical Dimensions W x D x H 17 x 8 x 1 75 in 43 18x 20 32 x 4 45 cm 66 Cyclades PM IPDU Installer Administrator User Gui
12. Attach the loopback connector Connect the loopback connector shipped with the product to the OUT port of the Cyclades PM IPDU If necessary disconnect any cables connected to the OUT port of the Cyclades PM IPDU to allow for the connection of the loopback Wait one minute and then check the display If you are watching the Cyclades PM IPDU s console output using HyperTerminal or Minicom messages like the ones shown below are displayed AlterPath PM Copyright c 2002 2006 Avocent Corporation V 1 9 0 Jun 21 2006 Username PM DCD went ON on output port of IPDU 1 PM Trying to detect loopback cable on OUT port of IPDU 1 PM Loopback detected Changing administrator password to default PM Please remove the loopback cable now PM DCD went OFF on output port of IPDU 1 PM IPDU 1 PM OUT 8 Remove the loopback connector After one minute you may remove the loopback connector from the OUT port of the Cyclades PM IPDU Now the password for the user admin is reset to the default pm8 and you should be able to log into the Cyclades PM IPDU using the default username password Change the password for the admin if desired by entering the passwd command Enter the save command to save the configuration 26 Cyclades PM IPDU Installer Administrator User Guide 7 If you need to recover the password of many Cyclades PM IPDUs connected in a daisy chain go to step 1 and perform the procedure on each Cyclades
13. Cyclades PM IPDU Installer Administrator User Guide upgrade The upgrade command is available only to the administrator This command goes directly to the boot options menu before actually rebooting You may either upgrade or boot the firmware NOTE For details on upgrading using the upgrade command or using the reboot command see Upgrading the Cyclades PM IPDU Firmware on page 26 Syntax upgrade lt IPDU gt lt IPDU_ID gt Arguments lt IPDU gt IPDU number in a daisy chain IPDU ID ldentification string previously set by the id command NOTE If you wish to upgrade more than one IPDU it is recommended that you upgrade the most remote IPDU first ver Chapter 4 Command Line Interface 59 Examples To upgrade 1 type pm gt upgrade 1 saving configuration to flash on IPDU 1 Done Copyright c 2003 Cyclades Corporation AlterPath PM KVM Boot Loader Version 1 1 Boot Menu 1 Upgrade Firmware 2 Boot Firmware Enter choice 1 or 2 1 Erasing firmware done Downloading image Please send file in 10 seconds done V_1 6 0 compatible Saving configuration to flash on IPDU 1 Done AlterPath PM Copyright c 2002 2006 Avocent Corporation V 1 9 0 Jun 21 2006 PM IPDU 1 PM OUT 10 Username admin Password The ver command shows the current software version and hardware model information of the selected PM IPDU Syntax ver lt IPDU gt lt IPDU_ID gt Of ver 60 Cycl
14. PM IPDU in the chain Upgrading the Cyclades PM IPDU Firmware Starting with version 1 1 0 the Cyclades PM IPDU firmware may be upgraded through its IN port The upgrade procedure described here is only valid for units that are currently running firmware versions 1 3 0 or greater If your Cyclades PM IPDU is running an older firmware version please follow the instructions in the manual that corresponds to the firmware currently installed on the PM IPDU Visit ftp ftp cyclades com pub cyclades alterpath pm doc for older versions of this manual To upgrade PM IPDU firmware 1 Download the new Cyclades PM IPDU firmware from the Cyclades web site After downloading the Cyclades PM IPDU firmware file save it to the workstation connected to the Cyclades PM IPDU console IN port 2 Using either Hyperterminal or Minicom log into the Cyclades PM IPDU as admin and type in the command pm gt upgrade lt IPDU gt If you are currently logged in as a different user log out and then login as admin The lt IPDU gt is the number of the IPDU to which you want to upgrade the firmware If you have only one Cyclades PM IPDU type upgrade 1 If you have for instance three units in a daisy chain type upgrade 3 or upgrade 2 depending on which unit you want to upgrade NOTE If you have a daisy chain and you want to upgrade all units you should start from the last unit and work your way towards the first Chapter 3 Configuration 27 Afte
15. Up the PM IPDU sidera ee ee Oe Rt ger bienes 20 Making a Direct Connection for Console Access iii 20 Chapter 3 Configuration 2 22 else else 23 Default Configuration Parameters sine 23 Initial Configuration Using the Command Prompt ss 24 Resetting the Admin Password obs siete e ep eh t dett sten 25 Upgrading the Cyclades PM IPDU Firmware iii 26 Chapter 4 Command Line Interface nee 31 PM IPDU User Interface 5 e te ea ek t e rs ea d eb exeo ie 31 Daisy chained PM IPDUS in the login prompt ss 31 Logging into the PMIPDU eet aan cedes denim innen 32 Commands err pe E d pde ed e E et edd DH 32 Gddser Va edo PR A es etant 33 np EE 34 ASSIST dr ik M PR S 34 buzzer MEE IE 35 CULT CE 35 C rtenitprotectiOn au oi d e e d ROTE CO PER HR canes ORE ge Fd ep Een E 36 CULT SOG MEE 37 A REES NEE Rt rele deste eite S eie TEST 38 AA at ra pet ee NN 39 AA H 39 display T 40 ORs EE 41 factor defaults ste ir i t da AA Pe RE PUDE ee 41 help RE T RE 42 Table of Contents v HIWOCD ssa ad 44 E NO 45 AA AAA B EAN 46 isteria BRR e LAO E a n 47 dc M EE 48 Un M
16. and the default password is pm8 After a successful login the PM IPDU command prompt appears after which you may use any of the commands described in this chapter After logging in the administrator may choose to change his or her password through the passwd command seen later Passwords may be set to null which indicates that no password is needed Commands All commands are available to the admin user and most commands are available to regular users as well Table 4 1 User Commands Regular User Command Regular User Command current on page 35 off on page 49 currseg on page 37 on on page 50 cycle on page 38 passwd on page 50 exit on page 41 status on page 54 help on page 42 temperature on page 56 humidity on page 43 unlock on page 57 interval on page 46 ver on page 59 list on page 47 voltage on page 60 lock on page 48 whoami on page 61 Chapter 4 Command Line Interface 33 The following commands are available only to the admin user Table 4 2 Admin User privileged Commands Admin User Command Admin User Command adduser on page 33 hwocp on page 44 alarm on page 34 idon page 45 assign on page 34 name on page 48 buzzer on page 35 reboot on page 51 currentprotection on page 36 restore on page 53 dbsync on page 39 save on page 53 deluser on page 39 syslog on page 55 display on page 40 unassign on page 57 factory_d
17. enter the following pm gt alarm Alarm threshold on IPDU 1 is 5 6A Alarm threshold on IPDU 2 is 7 8A assign The assign command assigns an outlet to a given user The user is then be able to manage such outlets This command is available to the admin user only Syntax assign lt outlet_number gt lt user gt Arguments outlet number Outlet number such as 5 outlet name such as sunfire or group of outlets such as 1 3 5 lt user gt Desired username Chapter 4 Command Line Interface 35 Examples To assign outlet 4 6 7 and 8 to user tess enter the following pm gt assign 4 6 8 tess 4 Outlet assigned to tess Outlet assigned to tess 6 7 Outlet assigned to tess 8 Outlet assigned to tess buzzer The buzzer command displays or changes the buzzer notification status When set to on a buzzer sounds when the current exceeds the threshold This command is available to the admin user only Syntax buzzer lt on off status gt Arguments on Enables buzzer off Disables buzzer status Displays the buzzer status Examples To get the current status of the buzzer notification enter the following pm gt buzzer status Buzzer is ON on IPDU 1 Buzzer is ON on IPDU 2 To turn buzzer notification on or off enter the following pm gt buzzer on Buzzer turned ON on IPDU 1 Buzzer turned ON on IPDU 2 pm gt buzzer off Buzzer turned OFF on IPDU 1 Buzzer turned OFF on IPDU 2 current
18. in as admin enter the following pm gt passwd Password lt new password gt Re enter password Username password set for user admin To change the password of a regular user when logged in as that user enter the following pm gt passwd Password Re enter password Username password set for user alpha reboot The reboot command reboots a PM IPDU You may reboot a specific unit by issuing the reboot command followed by the unit s logical number or the unit s ID Issuing the reboot command without a parameter reboots the first unit in a chain not all the units in a chain This command is available to the admin user only Syntax reboot lt IPDU gt lt IPDU_ID gt Arguments lt IPDU gt IPDU number in a daisy chain lt IPDU_ID gt Identification string previously set by the id command 52 Cyclades PM IPDU Installer Administrator User Guide Examples To reboot the first unit of the chain or to reboot the unit in stand alone mode enter the following pm gt reboot saving configuration to flash on IPDU 1 Done Copyright c 2003 Cyclades Corporation AlterPath PM KVM Boot Loader Version 1 1 Boot Menu 1 Upgrade Firmware 2 Boot Firmware Enter choice 1 or 2 Timeout Booting V_1 6 0 compatible Saving configuration to flash on IPDU 0 Done AlterPath PM Copyright c 2002 2006 Avocent Corporation V 1 8 0 Jan 9 2006 PM IPDU 1 PM OUT 10 Username To reboot the a s
19. mode set to normal IPDU 2 Display mode set to 180 degrees rotated IPDU 3 Display mode set to show current and cycle each 2 seconds The exit command exits the session Syntax exit Arguments none Examples To exit the current session enter the following pm gt exit AlterPath PM Copyright c 2002 2006 Avocent Corporation V 1 9 0 Jun 21 2006 Username factory defaults The factory defaults command resets the unit to its factory configuration so that all outlets are on unlocked unnamed and no users are created When used with a daisy chain and no argument is given this command resets all units in the chain This command is available to the admin user only Syntax factory defaults lt IPDU gt lt IPDU_ID gt Arguments no argument resets all PM IPDUs in the daisy chain to factory default lt IPDU gt number of the PM IPDU in the chain IPDU ID Identification string previously set by the id command 42 help Cyclades PM IPDU Installer Administrator User Guide Examples To reset the factory defaults enter the following pm gt factory defaults 1 Setting configuration to defaults on IPDU 1 1 Outlet turned on 2 Outlet turned on 3 Outlet turned on 4 Outlet turned on 5 Outlet turned on 6 Outlet turned on 7 Outlet turned on 8 Outlet turned on Saving configuration to flash on IPDU 1 done The help command displays the system help message for all commands or for
20. offers a superior feature set that is not fully covered in this manual Please refer to the appropriate product documentation for more information on how to use the Cyclades PM IPDU with your specific implementation Hardware Configuration Options The Cyclades PM IPDU may be used in one of three hardware configurations Standalone Managed independently of any other hardware device See Standalone configuration on page 2 Daisy chained Multiple slave PM IPDUs connected to one another and managed by one master PM IPDU See Daisy chained configuration on page 3 Integrated Managed by a Cyclades TS terminal server Cyclades ACS advanced console server Cyclades OnSite branch office appliance one of the Cyclades KVM switch products or by any other console terminal management device See Integrated configuration on page 4 Standalone configuration In a standalone configuration the Cyclades PM IPDU operates independently of any other hardware such as the TS terminal server or ACS console server The following graphic displays a PM IPDU with the console port connected to a computer running HyperTerminal Kermit or Minicom Chapter 1 Introduction 3 RJ 45 to DB 9F Adaptor RJ 45 Cable PA Power Source xo User E meaa ToC LR W Toone n DI E Server Switch Figure 1 1 Standalone Configuratio
21. system requirements 13 T temperature command 56 terminal emulation program 13 21 U unassign command 57 United Kingdom 15 16 unlock command 57 upgrading PM firmware 26 US 15 16 USB serial adapter 21 user accounts 2 users adding 24 assigning outlets to 24 34 changing passwords of 50 deleting 39 unassigning outlets to 57 V ver command 59 W wall mounting 17 whoami command 61 ON Z Avocent The Power of Being There o For Technical Support www avocent com support Avocent Corporation 4991 Corporate Drive Huntsville Alabama 35805 6201 USA Tel 1 256 430 4000 Fax 1 256 430 4031 Avocent Asia Pacific Singapore Branch Office 100 Tras Street 15 01 Amara Corporate Tower Singapore 079027 Tel 656 227 3773 Fax 656 223 9155 Avocent Canada 20 Mural Street Unit 5 Richmond Hill Ontario L4B 1K3 Canada Tel 1 877 992 9239 Fax 1 877 524 2985 590 667 501A Avocent International Ltd Avocent House Shannon Free Zone Shannon County Clare Ireland Tel 353 61 715 292 Fax 353 61 471 871 Avocent Germany Gottlieb Daimler StraBe 2 4 D 33803 Steinhagen Germany Tel 49 5204 9134 0 Fax 49 5204 9134 99
22. which it is connected Daisy chaining PM IPDUs with the Cyclades ACS console server or Cyclades TS terminal server is similar to the daisy chained configuration as described in Daisy chained configuration on page 3 6 Cyclades PM IPDU Installer Administrator User Guide however in the integrated configuration the first Cyclades PM IPDU is connected to a Cyclades management device instead of a workstation Accessing the System Console Users and administrators may access the Cyclades PM IPDU either by making a direct console connection to the PM IPDU s IN port or by connecting the PM IPDU to a Cyclades console or KVM switch management device Direct console access While using the PM IPDU device independently of other Cyclades devices local users may connect directly to the system console port the IN port of the Cyclades PM IPDU using the console cable with the corresponding adaptor s For more information about connecting directly to the PM IPDU s console see Making a Direct Connection for Console Access on page 20 Console access through a management device While integrating the PM IPDU device with a Cyclades console or KVM management device such as the Cyclades ACS console server or the Cyclades OnSite remote users may access the Cyclades PM IPDU s console port through one of the following interfaces e Menu driven interface After using telnet or SSH to access the console port equivalent to the managed device on the co
23. 00 240 VAC Max Output Current Total 16A Max Output Current Each Outlet 10A Environmental Operating Temperature 50 122 F 10 50 C Relative Humidity 5 95 Mechanical Weight 8 lb 3 64 kg Physical Dimensions W x D x H 17 x 8x 1 75 in 43 18x 20 32 x 4 45 cm 68 Cyclades PM IPDU Installer Administrator User Guide Table A 10 PM10i 20A IPDU Specifications Characteristics Specifications Electrical Input Voltage 100 240 VAC Max Output Current Total 20A de rated to 16A Max Output Current Each Outlet 10A de rated to 8A Environmental Operating Temperature 50 122 F 10 50 C Relative Humidity 5 95 Mechanical Weight 8 lb 3 64 kg Physical Dimensions W x D x H 17 x 8x 1 75 in 43 18x 20 32 x 4 45 cm Table A 11 PM10i 32A IPDU and PM10i 32Au IPDU Specifications Characteristics Specifications Electrical Input Voltage 100 240 VAC Max Output Current Total 32A Max Output Current Each Outlet 10A Environmental Operating Temperature 32 122 F 0 50 C Relative Humidity 5 95 Mechanical Weight 12 lb 5 45 kg Physical Dimensions W x D x H 17 x 11 5 x 1 75 in 43 18x 29 21 x 4 45 cm Appendices 69 Table A 12 PM10i L30A IPDU Specifications Characteristics Specifications Electrical Input Voltage 100 240 VAC Max Output Current Total 30A de rated to 24A Max Output Current Each Outlet 10A
24. 0A model 69 L20A model 69 L30A 10 L30A model 70 81 PM20i 10 11 16A model 16 70 20A model 16 71 32A model 72 82 32Au model 72 82 L20A model 71 L30A model 71 81 82 PM20i 32A 11 PM20i 32Au 11 PM45 72 Index 87 PM8 7 15A model 63 20A model 64 L20A model 64 PM8i 8 79 10A model 64 PM8i 15A model 15 port console 21 ports In 20 21 22 Out 3 4 19 power cables modular input 14 PM10i 10A 15 PM10i 15A 16 PM20i 16A 16 PM20i 20A 16 powering on the AlterPath PM 20 R rack mount diagram 19 rack mounting AlterPath PM 16 18 holes 18 RAM 7 reboot 51 requirements system 13 resetting admin password 25 restore command 53 RJ 45 loopback connector 14 RJ 45 serial cable 21 RJ 45 straight through cable 13 RJ 45 to DB 9F adapter 21 RJ 45 to DB 9F straight through adapter 13 88 Cyclades PM Installer Administrator User Guide RJ 45 to RJ 45 7ft CATS cable 13 S save command 25 53 save configuration 53 sequential power up 1 shipping box contents 13 software upgrade 26 specifications PM10 15A 65 PM10 20A 65 PM10i 10A 66 PM10i 15A 67 PM10i 16A 67 PM10i 20A 68 PM10i 32A 68 PM10i 32Au 68 PM10i L30A 69 PM10 L20A 65 PM10 L30A 66 PM20 20A 69 PM20i 16A 70 PM20i 20A 71 PM20i 32A 72 PM20i 32Au 72 PM20i L20A 71 PM20i L30A 71 PM20 L20A 69 PM20 L30A 70 PM8 15A 63 PM8 20A 64 PM8i 10A 64 PM8 L20A 64 standalone configuration 2 3 status command 54 syslog command 55 system console accessing 6
25. 5 15P e 125VAC 20A power plug NEMA 5 20P e 125VAC 20A power plug NEMA L5 20P 125VAC 30A power plug NEMA L5 30P 20 125VAC 15A power receptacles NEMA 5 15R 125VAC 20A circuit breaker 15A 20A and 30A models Vertical mounting zero U Za Ed na Gal Sal Sal ga a algaj Spa sag Za ad za na Fa Gal 230 239 sa E Cyclades PM20i IPDU The Cyclades PM20i IPDU has the following features One of the following power plugs e 240VAC 16A power plug IEC320 C20 e 240VAC 20A power plug IEC320 C20 Twenty 240VAC 10A power receptacles IEC320 C13 240VAC 20A supplementary protector with a press to reset function on the L30A models 240VAC 15A branch circuit breaker with accidental off protected feature 30A model Chapter 1 Introduction 11 e Vertical mounting zero U Pes 0000000 13 3 3 3 C3 3 1 3 E33 EJ C3 o Figure 1 10 The Cyclades PM20i IPDU PM20i 32A IPDU and PM20i 32AU IPDU Cyclades PM20i 32A IPDU The Cyclades PM20i 32A IPDU has the following features e 32A input power cord IEC 309 plug e Twenty 240VAC 10A power receptacles IEC320 C13 e 240VAC two 16A magnetic circuit breakers with accidental off protection function e Vertical mounting zero U Refer to Figure 1 10 on page 11 for an i
26. DU e PM20 L20 IPDU e PM201 16A IPDU e PM20i 20A IPDU In the event of a current overload in any of these units the entire unit shuts down causing all outlets to disconnect PM8i IPDU and PM10i IPDU The PM8i IPDU and some versions of the PM10i IPDU 10 15 16 and 20 amps have two circuit breakers each Both circuit breakers are designed to protect different phases of the same circuit inside the unit If either one of the two circuit breakers trips the entire unit will shut down PM10 L30A IPDU The PM10 L30A IPDU has two 15 amp circuit breakers The first circuit breaker controls outlets 1 through 5 and the power supply to the logic board the second circuit breaker controls outlets 6 through 10 If the total current flow to outlets 6 through 10 exceeds 15 amps due to equipment connected to these outlets then the second circuit breaker will trip causing outlets 6 through 10 to shut down This does not affect outlets 1 through 5 which are controlled by the first circuit breaker If however current overload causes the first circuit breaker to trip then the entire power unit shuts down because the power supply is also tied to the first circuit breaker Refer to Table C 1 Circuit Breaker Trip Time on page 83 to determine the time it takes for the circuit breaker to trip based on the amount of current overload 80 Cyclades PM IPDU Installer Administrator User Guide 15 amps cuit Breaker 2 EC Circuit Breaker 1 Circui 3
27. F Maximum 25 0 C 77 0 F To reset the maximum temperature registered use reset as a argument enter the following pm gt temperature reset IPDU 1 Clearing maximum recorded temperature to zero IPDU 2 Clearing maximum recorded temperature to zero Chapter 4 Command Line Interface 57 unassign The unassign command removes the assignment of an outlet or group of outlets from a given user This command is available to the admin user only Syntax unassign lt outlet_string gt lt user gt Arguments outlet string Outlet number such as 5 outlet name such as sunfire or group of outlets such as 1 3 5 lt user gt Desired username Examples To unassign outlet 2 and 4 from user diderot enter the following pm gt unassign 2 4 diderot 2 Outlet no longer assigned to diderot 4 Outlet no longer assigned to diderot unlock The unlock command unlocks an outlet or group of outlets in the current state The response to this command is a list of status lines one per power port Syntax unlock all lt outlet_string gt Arguments lt outlet_string gt Outlet number such as 5 outlet name such as sunfire or group of outlets such as 1 3 5 all Unlocks all outlets in the PM IPDU or PM IPDU daisy chain Examples To unlock outlets 2 3 4 and 8 enter the following pm gt unlock 2 4 8 2 Outlet unlocked 3 Outlet unlocked 4 Outlet unlocked 8 Outlet unlocked 58
28. If the PM IPDU has already booted before you connect to the PM IPDU through the console the Login prompt appears On the Boot Menu you may enter 2 or just wait approximately 12 seconds to select the Boot Firmware option The Login prompt appears Daisy chained PM IPDUs in the login prompt Number of PM IPDUs If no PM IPDUs are daisy chained the PM IPDU line appears only once and the value is 1 If there are any PM IPDUs daisy chained to the first PM IPDU the PM IPDU line appears once for each PM IPDU in the chain For each PM IPDU the value is incremented by 1 The final appearance of the PM IPDU line will show the total number of PM IPDUS in the daisy chain Number of PM IPDU outlets If no PM IPDUs are daisy chained the PM OUT line appears only once and the value is equal to the number of outlets on the PM IPDU If there are any PM IPDUs daisy chained to the first PM IPDU the PM OUT line appears once for each PM IPDU in the chain For each PM IPDU the value shows the cumulative total of outlets until the total number of outlets for the entire chain is displayed 32 Cyclades PM IPDU Installer Administrator User Guide Logging in to the PM IPDU After the Username prompt enter your username NOTE If there are daisy chained PM IPDUs you will need to press Enter after the final PM OUT line appears After the Password prompt enter the password for the unsername entered The default user is admin
29. ON Avocent Cyclades PM IPDU Installer Administrator User Guide o m E FCC Warning Statement The Cyclades PM IPDU has been tested and found to comply with the limits for Class A digital devices pursu ant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful in terference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Installation amp Service Manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user is required to correct the problem at his or her own expense Canadian DOC Notice The Cyclades PM IPDU does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le Cyclades PM n mete pas de bruits radio lectriques d passant les limites applicables aux appareils num ri ques de la classe A prescrites dans le r glement sur le brouillage radio lectrique edict par le Minist re des Communications du Canada Cyclades PM IPDU Installer Administrator User Guide Avocent the Avocent logo The Power of Being There and Cyclades are registered trademarks of Avocent Corporation All
30. Sie bitte sofort die Netzverbindung und kontaktieren Cyclades Wichtig Bitte halten Sie Ihren Cyclades PM IPDU vor Hitzequellen entfernt Appendices 75 Istruzioni di Sicurezza Vi preghiamo di attenervi alle seguenti direttive per la vostra sicurezza e un sicuro utilizzo dell Cyclades PM IPDU PERICOLO Tutte le prese dell Cyclades PM IPDU sono sotto alta tensione Occorre prendere precauzioni PERICOLO Per evitare di prendere la scossa inserire la spina dell Cyclades PM IPDU nell appropriata presa a terra L alimentatore equipaggiato con una spina a tre poli per assicurare un corretto collegamento Non utilizzare adattatori e non rimuovere la spina a tre poli dal cavo Non utilizzare prolunghe PERICOLO Non inserire oggetti nelle aperture dell Cyclades PM IPDU Farlo potrebbe causare un incendio o danneggiare i componenti interni PERICOLO C la possibilit che la fase o la terra rimanga sotto tensione anche se uno degli interruttori disattivato Importante Le Cyclades PM IPDU certificato per uso aziendale e solamente in luogo chiuso Importante Per proteggere le Cyclades PM IPDU da fluttuazioni di corrente elettrica utilizzare un limitatore di Sovracorrente un condizionatore di linea o un gruppo di alimentazione continua UPS Importante Assicurarsi che niente giaccia sui cavi dell Cyclades PM IPDU e che questi non causino intralcio al passaggio Importante Non versare cibo o liquidi sull Cyclades PM IPDU N
31. The current command displays the total current drawn by Cyclades PM IPDUs and the maximum current the unit has drawn current peak It may also be used to clear the saved peak current value 36 Cyclades PM IPDU Installer Administrator User Guide Syntax current lt IPDU gt lt IPDU_ID gt reset Arguments lt IPDU gt IPDU number in a daisy chain lt IPDU_ID gt Identification string previously set by the id command reset Clears the saved peak current value Examples To get the current status for all units enter the following pm gt current IPDU 1 True RMS current 2 2A Maximum current 9 4A IPDU 2 True RMS current 2 0A Maximum current 10 2A To get the current status for a specific unit enter the following pm gt current 2 IPDU 2 True RMS current 2 4A Maximum current 10 2A To reset maximum current drawn enter the following pm gt current reset IPDU 1 Clearing maximum recorded current to zero IPDU 2 Clearing maximum recorded current to zero currentprotection The currentprotection command turns on and off the over current protection feature The overcurrent protection does not let any outlet be turned on if the current drawn by the unit is greater than the current threshold configured with the command alarm This command may also be used to display the current protection status This command is available to the admin user only Syntax currentprotection lt on off status gt Arguments on Enables ove
32. U Installer Administrator User Guide The on command turns an outlet or a group of outlets on If more than one outlet is selected there will be an interval between outlets being powered on the interval is defined by the interval command This command works on outlets in a PM IPDU daisy chain Syntax on all lt outlet string gt Arguments all Turns on all outlets in the PM IPDU or PM IPDU daisy chain lt outlet_string gt Outlet number such as 5 outlet name such as sunfire or group of outlets such as 1 3 5 Examples To turn on outlets 1 3 4 and 5 type pm gt on 1 3 5 1 Outlet turned on 3 Outlet turned on 4 Outlet turned on 5 Outlet turned on passwd The passwd command sets a password The Administrator has a default password pm8 which may be changed Regular users may change or set only their own password The Administrator may change his or her own password or any regular user s password Syntax passwd lt user_name gt Arguments lt user_name gt Name of the user whose password is being changed no argument To change admin password if logged in as admin To change lt user gt password if logged in as lt user gt Chapter 4 Command Line Interface 51 Examples To change the password for user alpha when logged in as admin enter the following pm gt passwd alpha Password Re enter password Username password set for user alpha To change the admin password must be logged
33. U on page 7 e Cyclades PM8i IPDU on page 8 e Cyclades PM10 IPDU on page 8 e Cyclades PM10i IPDU on page 9 e Cyclades PM10i L30A IPDU on page 9 e Cyclades PM10i 32A IPDU on page 9 e Cyclades PM10i 32Au IPDU on page 10 e Cyclades PM20 IPDU on page 10 e Cyclades PM20i IPDU on page 10 If needed see Appendix A Specifications on page 63 for more electrical hardware and environment details about each model See Supplied with the PM IPDU on page 13 Cyclades PM8 IPDU The Cyclades PM8 IPDU has the following features e One of the following power plugs e 125VAC ISA NEMA 5 15P e 125VAC 20A NEMA 5 20P e 125VAC 20A NEMA L5 20P e Eight 125VAC 15A power receptacles NEMA 5 15R e 125VAC 20A circuit breaker e Vertical mounting zero U Figure 1 4 Cyclades PM8 IPDU 8 Cyclades PM IPDU Installer Administrator User Guide Cyclades PM8i IPDU The Cyclades PM8i IPDU has the following features e One 240VAC 8A power inlet 1EC320 C14 See PM8i 10A IPDU and PM10i 10A IPDU power cables on page 15 for a list of which power cables are supplied by region e Eight 240VAC 8A power receptacles IEC320 C13 e 240VAC IOA supplementary protector Horizontal 1 5U mounting Power Outlets IEC320 C13 OUT Port d Power us IN Port Current Display Figure 1 5 Cyclades PM8i IPDU Cyclades PM10 IPDU The Cyclades PM10 IPDU has the follo
34. a single command when specified NOTE When the admin user is logged in the help command displays all commands When a regular user is logged in the help command displays only the regular user commands Syntax lt command gt help or help Arguments lt command gt Any available command Examples To view the system help message for a specific command enter the command followed by help pm gt syslog help Usage syslog lt on off status gt Turn the syslog messages on the console on or off Chapter 4 Command Line Interface 43 To view the system help message for all commands enter the following pm gt help Available commands adduser alarm assign buzzer current currentprotection currseg cycle dbsync deluser display exit factory defaults help hwocp humidity id interval list lock name off on passwd reboot restore save status syslog temperature unassign unlock upgrade ver voltage whoami NOTE To get detailed help on the commands listed above type lt command gt help NOTE Some commands accept as input a data type called lt outletString gt lt outletString gt is a string representing one or more outlets This string can be one single outlet Examples on 3 turn on outlet 3 off router turn off the outlet called router a group of outlets Examples status 1 3 5 get status of outlets 1 3 and 5 lock 2 5 7 lock the outlets 2 5 6 and 7 humidity The humidity command displays the C
35. ades PM IPDU Installer Administrator User Guide Arguments lt IPDU gt IPDU number in a daisy chain lt IPDU_ID gt Identification string previously set by the id command no argument Displays version information for the PM IPDU and for all PM IPDUs ina daisy chain Examples To view the current software version of all IPDUs in a daisy chain enter the following pm gt ver IPDU 1 Hw with 10 outlets 16 AMPs max Sw V 1 9 0 Jun 21 2006 id mila model 7 IPDU 2 Hw with 8 outlets 15 AMPs max Sw V 1 9 0 Jun 21 2006 id sarah model 23 NOTE If an IPDU has an id assigned to it the ver command displays the word id followed by the name of the IPDU and the model number of the PM IPDU however if no id is configured for the IDPU the ver command displays the word id without a name following it as shown below pm gt ver IPDU 1 Hw with 10 outlets 16 AMPs max Sw V 1 9 0 Jun 21 2006 id model 7 IPDU 2 Hw with 8 outlets 15 AMPs max Sw V 1 9 0 Jun 21 2006 id model 23 To get this information for a specific unit provide the unit number as an argument pm gt ver 2 IPDU 2 Hw with 8 outlets 15 AMPs max Sw V 1 9 0 Jun 21 2006 id sarah model 23 voltage The voltage command shows the true RMS voltage This command only works on PM IPDU models with a voltage sensor Syntax voltage lt IPDU gt lt IPDU_ID gt AB AC BC Arguments lt IPDU gt IPDU number in a daisy chain lt IPDU_ID gt identification stri
36. ative Humidity 5 95 Mechanical Weight 17 Ib 7 73 kg Physical Dimensions W x D x H 2 0 x 2 8 x 66 in 5 18 x 7 11 x 167 6 cm Interface Pinouts The following table illustrates the Cyclades PM IPDU s pinouts for the IN and OUT RS 232 serial ports RJ 45F connectors Table A 19 Pinouts for IN and OUT RS 232 Serial Ports Signal Name Function VO In Pin OUT Pin RTS Request to Send O 5 1 DTR Data Terminal Ready O 7 2 TxD Transmit Data O 6 3 Gnd Ground N A 4 4 CTS Clear to Send 1 1 5 RxD Receive Data 1 3 6 DCD Data Carrier Detect 1 2 7 DSR Data Set Ready 1 8 8 Appendices 73 Appendix B Safety Instructions Follow the safety precautions in this document when installing and operating the Cyclades PM See the following instructions e Safety Instructions on page 73 e Sicherheitsanweisungen on page 74 e Istruzioni di Sicurezza on page 75 e Instru es de Seguran a on page 76 e Instrucciones de seguridad on page 77 Instructions de s curit s on page 78 e Circuit Breakers on page 79 Safety Instructions Read all the following safety guidelines to protect yourself and your Cyclades PM DANGER All outlets of the Cyclades PM output high voltage Necessary precautions should be taken TXT _ _ _ DANGER To help prevent electric shock plug the Cyclades PM into a
37. ature that prevents all power outlet receptacles from turning on at once eliminating the potential of current surges that could render the equipment inoperable Together with the global current monitoring the sequential power up feature lets users safely install more equipment on existing power circuits without the worry of current overloads 2 Cyclades PM IPDU Installer Administrator User Guide Support for daisy chaining The IPDU has a fixed number of power outlet receptacles but with daisy chaining capabilities users may increase capacity by connecting the control interfaces of several Cyclades PM IPDUs in a series Creation of user accounts The Cyclades PM IPDU allows one administrator and up to eight users not simultaneously to connect to it through its RS 232 serial port After a successful authentication it performs the following functions Reads and displays the total current being used by the entire Cyclades PM IPDU Manages power outlets by powering them up and down locking and unlocking them and or power cycling them Manages users Monitors power variables Can be used independently of any other hardware and controlled by any simple terminal access program like Minicom on Linux or HyperTerminal on Microsoft operating systems Integration with Cyclades management products When used with the ACS advanced console server the TS terminal server the OnSite branch office appliance or the KVM switch the Cyclades PM IPDU
38. atus Displays the current syslog status of all PM IPDUs on the daisy chain no argument Same as status Examples To get the current status of the syslog notification enter the following pm gt syslog Syslog is ON on IPDU 1 Syslog is ON on IPDU 2 56 Cyclades PM IPDU Installer Administrator User Guide To turn on and off the syslog notification enter the following as necessary pm gt syslog on Syslog turned ON on IPDU 1 Syslog turned ON on IPDU 2 pm gt syslog off Syslog turned OFF on IPDU 1 Syslog turned OFF on IPDU 2 temperature The temperature command displays the Cyclades PM IPDU s surrounding temperature and the maximum temperature the unit has registered temperature peak It may also be used to clear the saved peak temperature value Syntax temperature lt IPDU gt lt IPDU_ID gt reset Arguments lt IPDU gt IPDU number in a daisy chain lt IPDU_ID gt Identification string previously set by the id command reset Resets the maximum temperature registered Examples To get the temperature for all units in a daisy chain enter the following pm gt temperature IPDU 1 Temperature 36 1 C 96 9 F Maximum 36 1 C 96 9 F IPDU 2 Temperature 20 0 C 68 0 F Maximum 25 0 C 77 0 F IPDU 3 Does not have temperature sensor To get the temperature for specific unit provide the unit number as an argument enter the following pm gt temperature 2 IPDU 2 Temperature 20 0 C 68 0
39. ckground information and procedures for installing configuring and maintaining the Cyclades Power Management PM Intelligent Power Distribution Unit IPDU family This guide offers procedures for a stand alone configuration If you are integrating your PM IPDU with a Cyclades KVM or console management device please see the related installation instructions for that product The Cyclades PM IPDU enables remote power control of servers and network gear When used in conjunction with Cyclades console servers or KVM devices the Cyclades PM IPDU delivers easier management capabilities and faster problem solving by integrating console K VM access and power control into one single interface The following sections describe general features common to all PM IPDU models in addition to pointing out specific features of certain units Features and Benefits The following sections describe common features among all Cyclades PM IPDU units Alarms and monitoring The Cyclades PM IPDU delivers accurate real time global current monitoring of all connected devices via the user interface screen or locally through an LED digital display Users have the ability to set a current alarm threshold that once exceeded will cause the Cyclades PM IPDU to sound an alarm or send a notification message or both The LED current display also blinks when the alarm threshold is exceeded Sequential power up The Cyclades PM IPDU incorporates a sequential power up fe
40. d Environment Factor Recommendation Reliable Grounding Reliable grounding of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit such as power strips or extension cords NOTE Install a Cyclades PM IPDU zero U model in a location where there is an adjacent and accessible wall socket outlet To mount the Cyclades PM8i IPDU PM10 IPDU or PM10i IPDU 1 Locate the appropriate sets of holes on the PM IPDU Holes for Front Mounting Holes for Back Mounting o o O 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 o o Side of the PM IPDU Figure 2 2 Rack Mounting Holes on the PM8i IPDU PM10 IPDU and PM10i IPDU 2 Connect the two supplied brackets to the PM IPDU connecting one bracket to each side of the box 3 Foreach bracket insert a screw through each of the three holes on the bracket into the appropriate holes at either end of the PM IPDU The following figure shows the bracket flanges on the front of the PM IPDU after the brackets are installed E
41. de Table A 6 PM10 L30A IPDU Specifications EEE EEE Characteristics Specifications Electrical Input Voltage 100 125 VAC Max Output Current Total 30A de rated to 24A Max Output Current Each Outlet 15A de rated to 12A Environmental Operating Temperature 50 122 F 10 50 C Relative Humidity 5 95 Mechanical Weight 8 lb 3 64 kg Physical Dimensions W x D x H 17 x 8x 1 75 in 43 18x 20 32 x 4 45 cm Table A 7 PM10i 10A IPDU Specifications Characteristics Specifications Electrical Input Voltage 100 240 VAC Max Output Current Total 10A Max Output Current Each Outlet 10A Environmental Operating Temperature 50 122 F 10 50 C Relative Humidity 5 95 Mechanical Weight 8 lb 3 64 kg Physical Dimensions W x D x H 17 x 8x 1 75 in 43 18x 20 32 x 4 45 cm Appendices 67 Table A 8 PM10i 15A IPDU Specifications EFE EEE EEE Characteristics Specifications Electrical Input Voltage 100 240 VAC Max Output Current Total 15A de rated to 12A Max Output Current Each Outlet 10A de rated to 8A Environmental Operating Temperature 50 122 F 10 50 C Relative Humidity 5 95 Mechanical Weight 8 lb 3 64 kg Physical Dimensions W x D x H 17 x 8x 1 75 in 43 18x 20 32 x 4 45 cm Table A 9 PM10i 16A IPDU Specifications Characteristics Specifications Electrical Input Voltage 1
42. ealand CAB0194 United Kingdom and Ireland fuse limited to 13A as per BS1363 PM10i 20A IPDU and PM 20i 20A IPDU power cables Table 2 5 PM10i 20A IPDU and PM 20i 20A IPDU Power Cables P N Type CAB197 US NEMA L6 20P CAB0195 US NEMA 5 20P CAB0198 US NEMA L5 20P Optional outlet cable package The following cable packages may be ordered separately for the IEC PM IPDU models e 8 outletcables C13 female to C14 male ACS0040 e 10 outlet cables C13 female to C14 male ACS00046 Rack Mounting the Cyclades PM IPDU You may mount the PM IPDU on a rack or wall or place it on a desktop or other flat surface Two brackets are supplied with six Phillips screws for attaching the brackets to the PM8i IPDU the PM10 IPDU and the PM10i IPDU for mounting The PM8 IPDU has built in brackets e If you are not mounting the PM IPDU place the PM IPDU on a desk or table Chapter 2 Installation 17 e If you are mounting the PM IPDU obtain a Phillips screwdriver and appropriate nuts and bolts before starting the following procedure NOTE When mounting a Cyclades PM IPDU zero U model to a wall stud securely mount it by using a 10 or larger screw or use a drywall fastener rated min 25 lb 11 34 kg The following graphics depict the orientation of the brackets for front rack mounting PM IPDU e Bracket Figure 2 1 Rack Mounting a Cyclades PM10 IPDU PM10I IPDU and PM8ilPDU Installation environment When i
43. ed for installation 13 exit command 41 F factory_defaults command 41 firmware upgrade 26 flash memory 7 H hardware configuration options 2 help command 42 HyperTerminal 2 21 In port 3 20 21 connection 21 logging in through the 22 installation 13 installation environment 17 air flow 17 ambient temperature 17 circuit overloading 17 grounding 18 mechanical loading 17 temperature 17 installation environment 17 integration with Cyclades management products 2 interface pinouts 72 interfaces 7 interval command 46 introduction 1 Ireland 15 16 K Kermit 2 21 L list command 47 local work station 21 lock command 48 logging in 22 loopback connector 25 maximum outlets supported 19 Minicom 2 21 modular input power cables 14 mounting brackets 14 mounting the PM 18 N name command 24 48 naming outlets 24 NEMA 5 20p 16 NEMA 15 20p 16 NEMA 16 20p 16 New Zealand 15 16 O off command 49 on command 50 Out port 3 4 19 outlet cable package 16 outlet name 24 outlets assigning to users 24 naming 24 plugging devices into 20 overview PM 1 P part numbers 13 passwd command 50 pinouts In and Out RS 232 serial ports 72 plugging devices into outlets 20 PM10 8 15A model 65 20A model 65 L20A model 65 L30A model 66 79 80 PM10i 9 79 10A model 15 66 15A model 16 67 16A model 16 67 20A model 16 68 32A model 9 68 32Au model 10 68 L30A model 9 69 80 PM20 10 2
44. efaults on page 41 upgrade on page 58 NOTE When a range of outlets is used in a command and the range spans more than one PM IPDU in a daisy chain the range of outlets must not be specified by name The range of outlets may only be specified by number in this situation adduser The adduser command adds one username to the internal database A maximum of eight characters not case sensitive is allowed and a maximum of eight individual users is allowed This command is available to the admin user only Syntax adduser user Arguments user username Examples To add a user enter the following pm gt adduser popper Password Re enter password Username password set for user popper pm gt 34 Cyclades PM IPDU Installer Administrator User Guide alarm The alarm command sets and reads the current threshold This command is available to the admin user only Syntax alarm lt IPDU gt lt IPDU_ID gt lt threshold gt Arguments lt IPDU gt IPDU number in a daisy chain lt IPDU_ID gt Identification string previously set by the id command lt threshold gt The current threshold is the maximum allowed current on the power strip no argument Displays alarm status of all PM IPDUs in the daisy chain Examples To set the threshold enter the following pm gt alarm 1 5 6 Setting alarm threshold on IPDU 1 to 5 6A pm gt alarm 2 7 8 Setting alarm threshold on IPDU 2 to 7 8A To read the threshold
45. el caso l apparecchiatura si bagnasse togliere immediatamente l alimentazione e contattare Cyclades Importante Tenere lontano da fonti di calore 76 Cyclades PM IPDU Installer Administrator User Guide Instruc es de Seguranca Leia e siga as diretrizes de seguranga abaixo para sua protec o e de seu Cyclades PM PERIGO Alta voltagem est presente em todas as tomadas do Cyclades PM IPDU As devidas precauc es devem ser tomadas PERIGO Para evitar choques el tricos conecte o Cyclades PM IPDU a uma tomada devidamente aterrada O cabo de forca possui uma tomada com tr s pinos para ajudar a garantir que o devido aterramento seja feito Nao use adaptadores nem remova o pino de aterramento da tomada Nao use extens es para conex o el trica com o Cyclades PM IPDU PERIGO N o introduza objetos pelas aberturas existentes no Cyclades PM IPDU O curto circuito de componentes internos pode fazer com que o produto pegue fogo e causar choques el tricos PERIGO poss vel que haja tens o presente nos circuitos de fase ou neutro mesmo que um dos dispositivos de protec o contra sobrecorrente esteja atuando Importante O Cyclades PM IPDU destinado exclusivamente ao uso comercial em ambientes fechados Importante Para ajudar a proteger o Cyclades PM IPDU contra conseq ncias nocivas causadas por flutua es na rede el trica use um estabilizador filtro ou baterias que evitem eventual interrup o no fornecimento de energia Im
46. er N Control Board Power Supply VG amps Figure C 1 PM10 L30A IPDU Circuit Breakers PM10i L30A IPDU The PM10i L30A IPDU has two 15 amp circuit breakers The first circuit breaker controls outlets 6 through 10 the second controls outlets 1 through 5 In the event that the total current flow to outlets 6 through 10 exceeds 15 amps due to equipment connected to these outlets the first circuit breaker will trip causing outlets 6 through 10 to shutdown This does not affect outlets 1 through 5 which are controlled by the second circuit breaker As the PM10i L30A IPDU has the controller see Control Board in the figure below powered from the line side of one of the circuit breakers the whole unit will be inoperative only if both circuit breakers trip but the controller will still function When either circuit breaker trips only the power outlets of that segment will be affected and half of the outlets remain operative Independent power to controller 15 amps ff Syam Control Board Power Supply F Circuit Breaker 41 Circuit Breaker 2 Figure C 2 PM10i L30A IPDU Circuit Breakers PM10i 32A IPDU and PM10i 32Au IPDU The PM10i 32A has two 16 amp circuit breakers The first circuit breaker controls outlets 6 through 10 the second controls outlets through 5 In the event that the total curre
47. er the following pm gt currseg B IPDU 1 True RMS current for segment B 2 5A Maximum current for segment B 2 5A To reset the maximum recorded current for A and B enter the following pm gt currseg reset IPDU 1 Clearing maximum recorded current for segment A and B to zero cycle The cycle command power cycles an outlet or groups of outlets You may use the outlet number or the outlet name see command name for details Syntax cycle all lt outlet_string gt Arguments all Cycles all outlets in the PM IPDU or PM IPDU daisy chain outlet string Outlet number such as 5 outlet name such as sunfire or group of outlets such as 1 3 5 Examples To cycle one outlet enter the following pm gt cycle 3 3 Outlet turned off 3 Outlet turned on To cycle multiple outlets enter the following pm gt cycle 2 3 5 Outlet Outlet Outlet Outlet Outlet Outlet Outlet Outlet Outlet Outlet NA UV amp N NA UW IN dbsync turned turned turned turned turned turned turned turned turned turned 7 Off Oft off off off on on on on on Chapter 4 Command Line Interface The dbsync command synchronizes the user database for all PM IPDUs in the chain This command is available to the admin user only Syntax dbsync Arguments none Examples To synchronize the user database for all PM IPDUS in the chain enter the following pm gt dbs
48. f current overload 15 amps 15 amps i ee i Control Board 1 2113 114115116117 1 81191110 11 112 13 114 115 16 17 1181 19 120 Power Supply Circuit Breaker 1 5 v Circuit Breaker 2 Figure C 3 PM20 L30A IPDU Circuit Breakers PM20i L30A IPDU The PM20i L30A IPDU has two 15 amp circuit breakers The first circuit breaker controls outlets 11 through 20 the second controls outlets 1 through 10 In the event that the total current flow to outlets 11 through 20 exceeds 15 amps due to equipment connected to these outlets then the first circuit breaker will trip causing outlets 11 through 20 to shutdown This does not affect outlets 1 through 10 which are controlled by the second circuit breaker As the PM20i L30A IPDU has the controller see Control Board in the figure below powered from the line side of one of the circuit breakers the whole unit will become inoperative only when both circuit breakers trip however the controller will remain functioning 82 Cyclades PM IPDU Installer Administrator User Guide When either circuit breaker trips only the power outlets of that segment will be affected and half of the outlets remain operative Independent Power to Controller 15 Amps 15 Amps Control Board Po
49. h Used for the following CATS cable Along with an adaptor to connect a terminal or PC to the IN port See To access the console on page 21 To connect to a Cyclades console or KVM management device To connect to another Cyclades PM IPDU in a daisy chain See To daisy chain a PM IPDU on page 19 ADB0200 RJ 45 to DB 9F straight Along with an RJ 45 cable used to connect a terminal through adaptor or PC to a PC s COM port See To access the console on page 21 14 Cyclades PM IPDU Installer Administrator User Guide Table 2 1 PM IPDU Shipping Box Contents Part Numbers and Description Continued P N Description Purpose CON0132 RJ 45 loopback connector In case the administrator forgets the admin s password this is used to place in the OUT port to gain temporary access to the box using the factory default password See To reset the admin password using the loopback connector on page 25 210105 PM IPDU to DSR switch cable Used to connect Cyclades PM IPDU to an Avocent adaptor DSR switch HAR0220 2 mounting brackets with 8 screws Use to mount the Cyclades PM10 IPDU and PM10i 2 spares For PM10 IPDU and IPDU to a rack or wall See To mount the Cyclades PM10i IPDU PM8i IPDU PM10 IPDU or PM10i IPDU on page 18 HAR0302 2 mounting brackets with 5 screws Use to mount the Cyclades PM8i IPDU to a rack or 1 spare For PM8i IPDU wall See To mount the Cyclades PM8i IPDU PM10 IPDU or PM10i IPDU on page 18
50. he Cyclades PM20 IPDU ii 10 Figure 1 10 The Cyclades PM20i IPDU PM20i 32A IPDU and PM20i 32AU IPDU 11 Figure 2 1 Rack Mounting a Cyclades PM10 IPDU PMIOI IPDU and PMSilPDU 17 Figure 2 2 Rack Mounting Holes on the PMSi IPDU PM10 IPDU and PM10i IPDU 18 Figure 2 3 PM10 IPDU with Mounting Brackets Installed ss 18 Figure 2 4 Rack Mount for the Cyclades PM8i IPDU PM10 IPDU or PM Oi IPDU 19 Figure 2 5 Connecting a Local Work Station to the Cyclades PM IPDU i esses 21 Figure 3 1 Sending Firmware using HyperTerminal ss 28 Figure 3 2 Sending Firmware using Minicom sise 29 Figure C 1 PMIO L30A IPDU Circuit Breakers iii 60 Figure C 2 PMI0i L30A IPDU Circuit Breakers ss 80 Figure C 3 PM20 L30A IPDU Circuit Breakers ss 61 Figure C 4 PM20i L30A IPDU PM20i 32A IPDU and PM20i 32Au IPDU Circuit Breakers 82 viii Cyclades PM IPDU Installer Administrator User Guide ix LIST OF TABLES OF TABLES Table 2 1 PM IPDU Shipping Box Contents Part Numbers and Description suus 13 Table 2 2 PM8i 10A IPDU and PM10i 10A IPDU Power Cables ss 15 Table 2 3 PM10i 15A IPDU Power Cables sise 16 Table 2 4 PM10i 16A IPDU and PM 20i 16A IPDU Power Cables 16 Table 2 5 PM10i 20A IPDU and PM 20i 20A IPDU Power Cables 16 Table 2 6 PM IPDU Optimum Installation Environment 17 Table 41 Use
51. ile in 10 seconds Connected 0 18 45 ANSIW 9600 8 N 1 NUM Figure 3 1 Sending Firmware using HyperTerminal 2 Click the Browse button to set the proper path for the Cyclades PM IPDU firmware file located on your work station NOTE You must browse for the proper file and click the Send button within 10 seconds of selecting Transfer Send If you fail to do so an error message will appear and the transmission will fail You will then be given another 10 second window in which to repeat steps 1 through 4 3 Select Xmodem as the protocol 4 Click on the Send button To use Minicom in Linux 1 From the main screen press Ctrl A S for sending files The Upload pop up window appears 2 Select xmodem as the protocol The Select a file for upload window appears 3 Move the cursor next to the Cyclades PM IPDU firmware file for upload and press the Spacebar to tag it See Figure 3 2 4 Press Enter to start the file transfer Chapter 3 Configuration 29 gregg linux gregg Shell Konsole Session Edit View Bookmarks Settings Help Figure 3 2 Sending Firmware using Minicom If you use a different terminal emulator please refer to the documentation provided by the manufacturer on how to transfer files using the xmodem protocol If the file transfer is successful the Cyclades PM IPDU console displays the login prompt At this point the upgrade process of the unit is complete you may log into the Cyclade
52. lleiterzufuhr stehen GEFAHR Alle Ausg nge des Cyclades PM IPDU f hren Hochspannung Bitte die erforderlichen VorsichtsmaBnahmen einhalten GEFAHR Um elektrische Stromschlage zu vermeiden verbinden Sie bitte das Eingangskabel des Cyclades PM IPDU mit einer ausreichend geerdeten Stromversorgung Das Netzkabel ist mit drei Leitungen versehen um korrekte Erdung zu erm glichen Bitte benutzen Sie keine Adapterstecker und entfernen Sie nicht die Erdungsleitung Bitte verwenden Sie keine Verlangerungskabel GEFAHR Bitte f hren Sie keine Gegenst nde in die Offnungen des Cyclades PM IPDU ein Dies k nnte zu Branden oder elektrischen Schock durch Kurzschluss der internen Komponenten f hren GEFAHR Auch nach Offnung einer der beiden Sicherungen kann das Ger t noch unter Spannung ber die Phasen oder Nullleiterzufuhr stehen Wichtig Der Cyclades PM IPDU ist f r den Unternehmenseinsatz und den Gebrauch innerhalb von abgeschlossenen Geb uden vorgesehen Wichtig Um den Cyclades PM IPDU vor elektrischen Spannungsschwankungen zu sch tzen empfehlen wir den Einsatz von Uberspannungsreglern Spannungsgl ttern oder USVs Wichtig Bitte stellen Sie sicher daB keine Gegenstande auf den Kabeln des Cyclades PM IPDU liegen und die Kabel so gef hrt sind daB niemand darauf treten oder dar ber stolpern kann Wichtig Bitte sch tten Sie keine Nahrungsmittel oder Fl ssigkeiten auf den Cyclades PM IPDU Falls das Ger t naB werden sollte trennen
53. ly when used in an integrated configuration This menu allows you to invoke the various PM IPDU operations such as cycling switching on switching off and more The following sections offer basic instructions for configuring restoring the admin password and uploading firmware on the Cyclades PM IPDU for either the standalone or the daisy chained configuration For information about integrated use with the Cyclades ACS console server Cyclades TS terminal server Cyclades KVM switch or the Cyclades OnSite appliance refer to the documentation relevant to each product family Default Configuration Parameters The Cyclades PM IPDU s default configuration is as follows e User is admin e admin user s password is pm8 e All outlets are un named e All outlets are unassigned to user e All outlets are turned on All outlets are unlocked 24 Cyclades PM IPDU Installer Administrator User Guide Initial Configuration Using the Command Prompt To configure the PM IPDU you must have a work station connected to the console In port on the PM IPDU and be logged in as the admin user See Making a Direct Connection for Console Access on page 20 for instructions on connecting to the console If needed refer to Chapter 4 beginning on page 31 To change the default password If the default pm8 password is still in use change the admin password NOTE Changing the default password closes a security hole that could be easily exploited
54. mage of the Cyclades PM20i 32A IPDU Cyclades PM20i 32Au IPDU The Cyclades PM20i 32Au IPDU has the following features e 32A unterminated input power cord e Twenty 240VAC 10A power receptacles IEC320 C13 e 240VAC two 16A magnetic circuit breakers with accidental off protection function e Vertical mounting zero U Refer to Figure 1 10 on page 11 for an image of the Cyclades PM20i 32Au IPDU 12 Cyclades PM IPDU Installer Administrator User Guide 13 Installation Getting Started Collect the following equipment prior to installing and configuring the Cyclades PM IPDU in standalone configuration e One or more RJ 45 to RJ 45 straight through cables e AnRJ 45 to DB 9F straight through adaptor APC running a terminal emulation program See the following section for the list of other necessary items that come with the PM IPDU Supplied with the PM IPDU All PM IPDU models are shipped with the PM IPDU itself along with the items shown in Table 2 1 The entry for each part provides an illustration its part number P N description and purpose You may use check boxes to check off each item and you may use the part numbers from this table to reorder any of the parts Table 2 1 PM IPDU Shipping Box Contents Part Numbers and Description P N Description Purpose PAC0225 Cyclades PM IPDU Quick Basic installation guide for experienced users in Start Guide printed format CAB0018 RJ 45 to RJ 45 7ft straight throug
55. n NOTE The previous graphic displays the PM IPDU being connected to the local work station with the RJ 45 to DB 9F adaptor that is shipped with the product If your work station does not have a DB 9M COM port you may need to use a USB serial adaptor in order to connect to the computer s USB port For specific installation instructions see Rack Mounting the Cyclades PM IPDU on page 16 Daisy chained configuration In a daisy chained configuration multiple slave PM IPDUs are connected to one another and managed by a single master PM IPDU The PMs are linked together with RJ 45 cables connected to one PM IPDU s OUT port and the other PM IPDU s IN port This example shows four Cyclades PM IPDUs operating in a daisy chained environment PM IPDU 1 is connected to the local workstation and is the master PM IPDU while the other three PM IPDUs are slaves 4 Cyclades PM IPDU Installer Administrator User Guide RJ 45 to DB 9F Adaptor RJ 45 Cable Power Source no PM IPDU 1 User AE aa ooj TI TI TI LT LT LT TI TI TI IN Port 7 PMIPDU 2 E OUT Port PM IPDU 3 a ECA PM IPDU 4 POL RE NN BEH T
56. ng previously set by the id command Chapter 4 Command Line Interface 61 AB AC BC reserved for future use no argument displays the RMS voltage on all units if voltage sensors are available Examples whoami The whoami command shows the username of the user currently logged in Syntax whoami Arguments none Examples To view the current username enter the following pm gt whoami admin 62 Cyclades PM IPDU Installer Administrator User Guide 63 APPENDICES Appendix A Specifications Table A 1 PM8 15A IPDU Specifications Characteristics Specifications Electrical Input Voltage 100 125 VAC Max Output Current Total 15A de rated to 12A Max Output Current Each Outlet 15A de rated to 12A Environmental Operating Temperature 50 122 F 10 50 C Relative Humidity 5 95 Mechanical Weight 6 1 Ib 2 8 kg Physical Dimensions W x D x H 1 8 x 2 2 x 37 6 in 4 57 x 5 6 x 95 5 cm 64 Cyclades PM IPDU Installer Administrator User Guide Table A 2 PM8 20A IPDU and PM8 L20A IPDU Specifications Characteristics Specifications Electrical Input Voltage 100 125 VAC Max Output Current Total 20A de rated to 16A Max Output Current Each Outlet 15A de rated to 12A Environmental Operating Temperature 50 122 F 10 50 C Relative Humidity 5 95 Mechanical Weight 6 1 lb 2 8 kg Physical Dimensions W x D x H 1 8 x 2 2 x 37 6 in 4
57. nsole server type the power management hotkey Ctrl P by default to bring up a power management menu on the same screen e Web interface Once you are logged into the management device web interface access the power management functionality by selecting a Power Management or IPDU Power Management tab on the Web Manager See Integration with Cyclades management products on page 2 for more background information on integrating a PM IPDU with a Cyclades management device or refer to the appropriate user documentation for instructions on accessing the PM IPDU console through your specific Cyclades management device To connect a Cyclades PM IPDU to an Avocent DSR switch Use the included RJ 45 cable adaptor to connect a Cyclades PM IPDU to an Avocent DSR switch 1 Plug the male end of the adaptor into the DSR switch s SPC port 2 Plug one end of a straight through Cat 5 cable into the female end of the adaptor 3 Plug the other end of the Cat 5 cable into the PM IPDU s In port Chapter 1 Introduction 7 Component Overview General features are common among all products in the Cyclades PM IPDU family e 128 KB flash memory e 8KBRAM Two RJ 45 RS 232 interfaces e Digital global current display with two digits and seven segments e LEDs monitoring ON OFF status for each port Audible over current alarm e 8 bit Microcontroller equipped The following sections list features that are specific to each model e Cyclades PM8 IPD
58. nstalling the PM IPDU ensure that the following environment specifications are met Table 2 6 PM IPDU Optimum Installation Environment Environment Factor Recommendation Temperature The manufacturer s maximum recommended ambient temperature for the Cyclades PM IPDU is 122 F 50 C Elevated Operating Ambient Temperature If the Cyclades PM IPDU is installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient temperature Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient temperature See above Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern 18 Cyclades PM IPDU Installer Administrator User Guide Table 2 6 PM IPDU Optimum Installation Environment Continue
59. nt flow to outlets 6 through 10 exceeds 16 amps due to equipment connected to these outlets the first circuit breaker Appendices 81 will trip causing outlets 6 through 10 to shutdown This does not affect outlets 1 through 5 which are controlled by the second circuit breaker As the PM10i 32A has the controller powered from the line side of one of the circuit breakers the whole unit will be inoperative only if both circuit breakers trip but the controller will still function When either circuit breaker trips only the power outlets of that segment will be affected and half of the outlets remain operative PM20 L30A IPDU The PM20 L30A IPDU has two 15 amp circuit breakers The first circuit breaker controls outlets 11 through 20 the second controls outlets 1 through 10 as well as the power supply to the logic board In the event that the total current flow to outlets 11 through 20 exceeds 15 amps due to equipment connected to these outlets then the first circuit breaker will trip causing outlets 11 through 20 to shutdown This does not affect outlets 1 through 10 which is controlled by the second circuit breaker If however current overload causes the second circuit breaker to trip then the entire power unit shuts down because the power supply is also tied to the second circuit breaker Refer to Table C 1 Circuit Breaker Trip Time on page 83 to determine the time it takes for the circuit breaker to trip based on the amount o
60. on interval interval interval interval set set set set to to to to N N N N A A A A sec sec sec sec The list command lists users created and outlets assigned to each user for the administrator or just the outlets assigned to the user logged in at the moment for the regular user Synta list x Arguments none Exam ples As admin to list usernames and associated outlets in the internal database enter the following P m gt list gregg george mila sarah As mila to list mila s name and associated outlets in the internal database enter the following P m gt list 48 Cyclades PM IPDU Installer Administrator User Guide lock The lock command locks an outlet or group of outlets in the current state The response to this command is a list of status lines one per power port This command works on all PM IPDUs in a daisy chain Syntax lock all outlet string Arguments outlet string Outlet number such as 5 outlet name such as sunfire or group of outlets such as 1 3 5 Examples To lock outlets 1 2 and 6 enter the following pm gt lock 1 2 6 1 Outlet locked 2 Outlet locked 6 Outlet locked name The name command names an outlet A maximum of 16 alphabetic and numeric characters not case sensitive is allowed with these exceptions e The hyphen percent 96 and comma characters are not allowed e Numeric characte
61. onsole or KVM device master 2 Connect the other end of the RJ 45 cable to the IN port of the secondary Cyclades PM IPDU slave 20 Cyclades PM IPDU Installer Administrator User Guide 3 To connect another PM IPDU to the slave connect one end of an RJ 45 cable to the OUT port of the last PM IPDU in the chain 4 Repeat Step 3 until you have connected the desired number of PM IPDUs You may control up to 128 power outlets in any combination of PM IPDU models Plugging Devices Into PM IPDU Outlets In order to control power to a device the device must be plugged into one of the PM IPDU s power outlets To plug devices into PM IPDU outlets Plug all the devices you want to control into the Cyclades PM IPDU outlets Powering Up the PM IPDU Power up the Cyclades PM IPDU in order to begin managing power to its connected devices To power up the PM IPDU Plug the power cable into an adjacent AC power source NOTE The Cyclades PM IPDU must be powered by a receptacle with adequate circuit protection Making a Direct Connection for Console Access The system administrator must specify basic settings on the PM IPDU before users may connect to and manage the unit and the connected devices To prepare to perform necessary basic configuration make a direct connection to the PM IPDU by connecting a terminal or computer to the IN port as depicted in the following graphic Chapter 2 Installation 21
62. other marks are the property of their respective owners 2006 Avocent Corporation All rights reserved 590 667 501A ODE Ee Instructions This symbol is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance Dangerous Voltage This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons Power On This symbol indicates the principal on off switch is in the on position Power Off This symbol indicates the principal on off switch is in the off position Protective Grounding Terminal This symbol indicates a terminal which must be connected to earth ground prior to making any other connections to the equipment TABLE OF CONTENTS OF CONTENTS o EET vii List of Tables ix Chapter 1 Introduction ss inennnnensnenenennnnennnenes 1 Features and Benefits ie de t ett ette ee A tete 1 Alarms and monitoring PUR tts 1 Sequential power up ea nine 1 Support for daisy chaining sviter iatis e adi uns Gradi 2 Creation of user accounts sso ege er ee renti t ti re tre terea 2 Integration with Cyclades management products iii 2 Hardware Configuration Options i 2 Standalone configuration AAA epi eiat ree Hera ter eai de 2 Dai
63. pecific IPDU in the chain IPDU 2 shown enter the following pm gt reboot 2 PM DCD went OFF on output port of IPDU 1 PM IPDU 1 PM OUT 10 pm gt PM DCD went ON on output port of IPDU 1 PM IPDU 2 PM OUT 18 Chapter 4 Command Line Interface 53 restore save The restore command restores the configuration currently saved in flash This command is available to the admin user only Syntax restore Arguments N A Examples To restore the configuration currently saved in flash enter the following pm gt restore 1 Outlet turned on 2 Outlet turned on 3 Outlet turned on 4 Outlet turned on 5 Outlet turned on 6 Outlet turned on 7 Outlet turned on 8 Outlet turned on The save command saves the current configuration in the flash device built in to all Cyclades PM IPDU units This command saves the username password database and the specific information pertaining to each outlet such as outlet name outlet assignments outlet state This command is available to the admin user only If you save your configuration to flash it will be restored after the next reboot If you do not save your configuration to flash you will lose it all after the next reboot Syntax Save Arguments none 54 Cyclades PM IPDU Installer Administrator User Guide Examples To save the configuration to flash enter the following pm gt save Saving configuration to flash on IPDU 1 Done Saving configu
64. portante Garanta que nao haja nenhum objeto sobre os cabos do Cyclades PM IPDU e que eles nao estejam em locais de transito de pessoas para que nao sejam pisados e para que nao causem quedas ou acidentes Importante N o derrame alimentos ou l quidos sobre o Cyclades PM IPDU Se o produto for molhado disconete o da tomada imediatamente e entre em contato com a Cyclades Importante Mantenha o Cyclades PM IPDU longe de fontes de calor Appendices 77 Instrucciones de seguridad Lea y siga estas pautas de seguridad para protegerse a usted y a su Cyclades PM PELIGRO Todos los enchufes de salida Cyclades PM IPDU tienen alto voltaje Se deben tomar las precauciones necesarias PELIGRO Para ayudar a prevenir descargas el ctricas conecte el Cyclades PM IPDU en una fuente de energ a correctamente puesta a tierra El cable el ctrico est equipado de un enchufe del tres conectores para ayudar a asegurar la puesta a tierra apropiadamente No utilice adaptadores de enchufe ni quite el conector de tierra No utilice extensores con el Cyclades PM IPDU PELIGRO No empuje ningun objeto en las aberturas del Cyclades PM IPDU El hacerlo puede causar fuego o descargas el ctricas poniendo en cortocircuito los componentes interiores PELIGRO Existe la posibilidad de tensi n en cualquier conector del PM IPDU incluso si uno de los interruptores esta desabilitado Importante El Cyclades PM IPDU se piensa para la empresa y el uso de in
65. properly grounded power source The power cord is equipped with a three prong plug to help ensure proper grounding Do not use adaptor plugs or remove the grounding prong from the cable Do not use extension cords with the Cyclades PM DANGER Do not push any objects through the openings of the Cyclades PM Doing so may cause fire or electric shock by shorting out interior components DANGER There is a possibility of severe electrical shock from either the live or neutral side of any of the power outlets or their wiring even if one of the circuit breakers is disabled 1 IMPORTANT Cyclades PM is intended for enterprise and indoor use only IMPORTANT To help protect the Cyclades PM from electrical power fluctuations use a surge suppressor line conditioner or uninterruptible power supply IMPORTANT Be sure that nothing rests on the cables of the Cyclades PM and that they are not located where they may be stepped on or tripped over IMPORTANT Do not spill food or liquids on the Cyclades PM If it gets wet disconnect the power immediately and contact Cyclades IMPORTANT Keep your Cyclades PM away from heat sources 74 Cyclades PM IPDU Installer Administrator User Guide Sicherheitsanweisungen Bitte lesen und befolgen Sie diese Sicherheitsrichtlinien um sich und Ihren Cyclades PM IPDU vor Sch den zu bewahren GEFAHR Auch nach Offnung einer der beiden Sicherungen kann das Ger t noch unter Spannung ber die Phasen oder Nul
66. r Commands iet Anania und 32 Table 4 2 Admin User privileged Commands ss 33 Table A 1 PM8 15A IPDU Specifications iii 63 Table A 2 PM8 20A IPDU and PM8 L20A IPDU Specifications 64 Table A 3 PM8i 10A IPDU Specifications iii 64 Table A 4 PM10 15A IPDU Specifications ss 65 Table A 5 PM10 20A IPDU and PM10 L20A IPDU Specifications 65 Table A 6 PM10 L30A IPDU Specifications sense 66 Table A 7 PM10i 10A IPDU Specifications iii 66 Table A 8 PMI0i 15A IPDU Specifications iii 67 Table A 9 PMI0i 16A IPDU Specifications 67 Table A 10 PM10i 20A IPDU Specifications iii 68 Table A 11 PM10i 32A IPDU and PM10i 32Au IPDU Specifications 68 Table A 12 PM10i L30A IPDU Specifications ss 69 Table A 13 PM20 20A IPDU and PM20 L20A IPDU Specifications 69 Table A 14 PM20 L30A IPDU Specifications ss 70 Table A 15 PM20i 16A IPDU Specifications ss 70 Table A 16 PM20i 20A IPDU and PM20i L20A IPDU Electrical Specifications 71 Table A 17 PM20i L30A Specifications ii 71 Table A 18 PM20i 32A IPDU and PM20i 32Au IPDU Specifications 72 x Cyclades PM IPDU Installer Administrator User Guide Table A 19 Pinouts for IN and OUT RS 232 Serial Ports Table C 1 Circuit Breaker Trip Time sse Introduction This installation administration and user s guide provides ba
67. r current protection off Disables over current protection status Displays the current protection status Chapter 4 Command Line Interface 37 Examples To display current protection status for all units enter the following pm gt currentprotection status IPDU 1 Overcurrent protection is OFF IPDU 2 Overcurrent protection is OFF To enable current protection status for all units enter the following pm gt currentprotection ON IPDU 1 Overcurrent protection turned ON IPDU 2 Overcurrent protection turned ON To disable current protection status for all units enter the following pm gt currentprotection off IPDU 1 Overcurrent protection turned OFF IPDU 2 Overcurrent protection turned OFF currseg The currseg command lets you view the current for the lower or upper segment of outlets This command is only useful for IPDUs with dual current sensors 30A and 32A models The lower segment segment A would be outlets 1 5 on a PM 10 series IPDU and the upper segment segment B would be outlets 6 10 on a PM 10 series IPDU Syntax currseg A B reset Arguments A B segment A or segment B reset Clears the max recorded current for A amp B Example To view the current load of segment A enter the following pm gt currseg A IPDU 1 True RMS current for segment A 0 4A Maximum current for segment A 0 4A 38 Cyclades PM IPDU Installer Administrator User Guide To view the current load of segment B ent
68. r the upgrade command is executed the boot loader menu is displayed at the console as shown below pm gt upgrade 1 Copyright c 2003 Cyclades Corporation AlterPath PM KVM Boot Loader Version 1 1 Boot Menu 1 Upgrade Firmware 2 Boot Firmware Enter choice 1 or 2 1 3 At the boot loader menu select option 1 to upgrade the firmware The boot loader erases the firmware currently in the unit and asks you to upload the new firmware as shown below Copyright c 2003 Cyclades Corporation AlterPath PM KVM Boot Loader Version 1 1 Boot Menu 1 Upgrade Firmware 2 Boot Firmware Enter choice 1 or 2 1 Erasing firmware done Downloading image Please send file in 10 seconds 4 Use your terminal emulator program to upload the Cyclades PM IPDU firmware file to the PM IPDU using the Xmodem protocol To use HyperTerminal in Windows 1 From the top menu select Transfer Send The Send File pop up window appears 28 Cyclades PM IPDU Installer Administrator User Guide De 3 DB E AlterPath PM Copyright c 2002 2005 Cyclades Corporation V_1 7 0 Sep 15 2005 PM IPDU 1 PM OUT Username admin Password Folder C Documents and Settings Vina Filename L Send File pm gt upgrade 1 Protocol Copyright c 2003 Cycli modem RlterPath PM KVM Boot L Boot Menu 1 Upgrade Firmware 2 Boot Firmware Enter choice 1 or 2 1 Erasing firmware done Downloading image Please send f
69. ration to flash on IPDU 2 Done An error message will be displayed if there is an error while writing the configuration to flash status The status command displays the status of selected outlets Syntax status all lt outlet_string gt Arguments outlet string Outlet number such as 5 outlet name such as sunfire or group of outlets such as 1 3 5 all Displays the status of all outlets in a PM IPDU or PM IPDU daisy chain Examples To display the status of outlet 1 enter the following pm gt status 1 Outlet Name Status Interval s Users 1 gl Unlocked ON 0 00 gregg Chapter 4 Command Line Interface 55 To display the status of all outlets enter the following pm gt status all Outlet Name 1 2 3 4 ON 5 ON 6 ON 7 ON 8 ON syslog gl g2 g3 g4 2 40 g5 2 40 g6 2 40 g7 0 50 g8 0 50 george mila sarah george george S U U U U tatus nlocked ON nlocked ON nlocked ON nlocked sarah U U nlocked nlocked sarah U nlocked sarah U nlocked mila sarah Interval 0 00 2 40 0 00 s Users gregg gregg gregg The syslog command displays or changes the syslog notification status This command is available to the admin user only Syntax syslog on off status Arguments on Enables message to be displayed in the console when there is an over current situation off Disables the message notification st
70. riques en court circuitant des composants interne DANGER Il y a une possiblit de pr sence de courant pour la Phase et le Neutre m me si l un des relais lectrique est d sactiv Important L Cyclades PM IPDU est pr vu pour les entreprises dans un usage l int rieur seulement Important Pour aider prot ger l Cyclades PM IPDU des fluctuations d alimentation lectrique utilisez un filtre de surtension un conditioneur de ligne ou une source d alimentation qui ne peut pas tre interrompue Important Soyez s r que rien ne repose sur les cables de l Cyclades PM IPDU qu ils ne sont pas sur un lieu de passage qu ils ne peuvent pas tre pi tin et que l on ne peut pas tr bucher dessus Important Ne reversez pas de nourriture ou de liquides sur le Cyclades PM IPDU Si elle est humide deconnectez l alimentation lectrique imm diatement et contactez Cyclades Important Gardez l Cyclades PM IPDU distance des sources de chaleur Appendices 79 Appendix C Circuit Breakers The PM IPDU circuit breakers are designed to shut the power off to some or all of the PM IPDU outlets in case the rated current is exceeded The circuit breaker mechanism for each PM IPDU model is explained the in the following sections PM IPDU Units with One Circuit Breaker Only one circuit breaker is used for the following units e PM8 15A IPDU e PM8 20A IPDU e PM8 L20 IPDU e PMI10 15A IPDU e PM10 20A IPDU e PMIO L20 IPDU e PM20 20A IP
71. rs are not allowed as the first character of a name This command is available to the administrator user only Syntax name outlet number lt name gt Arguments outlet number Outlet number such as 5 name Desired outlet name Examples To name outlet 4 as nowhere enter the following pm gt name 4 nowhere 4 Outlet now named nowhere off Chapter 4 Command Line Interface 49 The off command turns an outlet or group of outlets off This command works on outlets in a PM IPDU daisy chain Syntax off all lt outlet string gt Arguments all Turns off all outlets in the PM IPDU or PM IPDU daisy chain lt outlet string gt Outlet number such as 5 outlet name such as sunfire or group of outlets such as 1 3 5 Examples To turn all outlets off enter the following pm gt off all o NN O Ul d WD KH Outlet Outlet Outlet Outlet Outlet Outlet Outlet Outlet turned turned turned turned turned turned turned turned off off off off off Off OTE off CAUTION The all argument will turn off all outlets in a PM IPDU or PM IPDU daisy chain To turn off outlets 2 through 7 or all outlets except 1 and 8 in a single PM8 IPDU enter the following pm gt off 2 7 JON UF WN Outlet Outlet Outlet Outlet Outlet Outlet turned turned turned turned turned turned off off off Off off off 50 on Cyclades PM IPD
72. s PM IPDU and perform actions as usual If the file transfer fails an error message appears on the PM IPDU console and the boot loader menu is displayed again so you may redo the firmware upgrade process The screen would be similar to the one shown below Erasing firmware done Downloading image Please send file in 10 seconds error Copyright c 2003 Cyclades Corporation AlterPath PM KVM Boot Loader Version 1 1 Boot Menu 1 Upgrade Firmware 2 Boot Firmware Enter choice 1 or 2 30 Cyclades PM IPDU Installer Administrator User Guide In this case select option 2 from the menu and repeat the firmware upload procedure If the problem persists contact Technical Support for assistance 31 Command Line Interface When using the Cyclades PM IPDU independently of other Cyclades products users and administrators may access the PM IPDU command line interface through a terminal emulation program by making a console connection from a local computer to the IN port on the PM IPDU See To access the console on page 21 for instructions PM IPDU User Interface You may access the PM IPDU user interface by following the instructions provided in To access the console on page 21 The menu that appears after connecting to the console depends on whether the PM IPDU has booted or not before you connect If you connect to the console before powering up the Cyclades PM IPDU or reboot while connected the Boot Menu appears
73. sy Chained configuration d mt bete ree Ee eee eee E steeds 3 Integrated configuration verre t e ee epe t Pb ede agenda 4 Accessing the System Console iii 6 Direct Console accessed aaa RIA aa 6 Console access through a management device ss 6 ComponentiOVEr VIEW idas 7 Cyclades EMSTPDO uns eet tet e rU Reis 7 Cyclades PM i IBDU outer oda eR RC PNE EPI E NER ERR YES S GREY 8 Cyclades PM 10 IP DU rigido o aed te de ble e a Ys an amp Cyclades PMTOEIPDU rade ah NOR ERR 9 Cyclades PM 10i L30A IPDU tirent ee ete rette ani 9 Cyclades PM10i 32A IPDU ie odo ER EE CER e tea adiada 9 Cyclades PM1OI 32AW IPDU css iii tii e Et eedem 10 Cyc lades PM20IPDU siasi leali ee eee De REP rede rer dodge 10 Cyclades PM 200 EP DG uta n d ere ecu tu hit neh 10 Cyclades PM20i 32A IPDU itte bte nda canada ta bins 11 Cyclades PM20i 32Aw LEDO ai d ete e ie ii 11 Chapter 2 Installation is eee iii rie erre ieri eci eri iii 13 Getting Started pini HR RP ERE ala Nara aes ae HERES 13 iv Cyclades PM IPDU Installer Administrator User Guide Supplied with the PM IPDU cid ee sn db apta aus etant eee i 13 Modular input power cables for the PM IPDU ins 14 Optional outlet cable package ss 16 Rack Mounting the Cyclades PM IPDU sciare 16 Installation environmehit atre t e e PR GR Rasa 17 Daisy Chaining PM IPDUS 5 aaa e C ERE ua REI E UND bonn 19 Plugging Devices Into PM IPDU Outlets ii 20 Powering
74. taller Administrator User Guide To display the ID of PM IPDU 2 enter the following pm gt id 2 IPDU 2 id QA To rename an ID to sammy using an existing ID QA enter the following pm gt id QA sammy IPDU 2 sammy To display the IDs of all PM IPDUs in the daisy chain enter the following pm gt id IPDU 1 id RED IPDU 2 id QA interval The interval command configures the power up interval for each outlet in the system The power up interval of an outlet is the time in seconds the unit will wait after turning this outlet on to turn on any other outlet This command is available to the admin user only Syntax interval lt outlet_number gt lt duration gt Arguments lt duration gt Sets the power up interval of outlets Valid intervals are from 0 to 100 Default value is 0 5 NOTE When this value is set to 0 0 there is still a power up interval of approximately 0 1 seconds between outlets outlet number Outlet number such as 5 outlet name such as sunfire or group of outlets such as 1 3 5 Examples To display the interval of outlet 1 enter the following pm gt interval 1 1 Outlet power on interval is 0 0 sec list Chapter 4 Command Line Interface 47 To set the interval of outlets 2 4 5 and 6 to a value of 2 4 enter the following pm gt interval 2 4 6 2 4 dii 4 Bis 6 Outlet power Outlet power Outlet power Outlet power on on on
75. terior solamente Importante Para ayudar a proteger el Cyclades PM IPDU contra fluctuaciones de la corriente el ctrica utilice un supresor de fluctuaciones acondicionador de l nea o fuente de alimentaci n ininterrumpida Importante Asegurese que nada se apoya sobre los cables del Cyclades PM IPDU y que no est n localizados donde puedan ser pisados cuando esten encendidos Importante No derrame alimentos o l quidos en el Cyclades PM IPDU Si se hubiera mojado desconecte la energ a inmediatamente y entre en contacto con Cyclades Importante Mantenga su Cyclades PM IPDU lejos de fuentes de calor 78 Cyclades PM IPDU Installer Administrator User Guide Instructions de s curit s Lisez et suivez les instructions de s curit pour votre protection et celle ce le Cyclades PM IPDU DANGER Toutes les prises de l Cyclades PM produisent une tension lectrique l v e Prenez les pr cautions d usage DANGER Pour aider viter tout choc lectrique branchez l Cyclades PM IPDU une source lectrique correctement li e la terre Le cordon lectrique est quip d une prise 3 broches pour aider assurer une connexion correcte avec la terre N utilisez pas d adaptateurs ou n enlevez pas la broche de la terre du cable N utilisez pas de rallonge lectrique avec l Cyclades PM IPDU DANGER Ne pas faire passer aucun objets travers les ouvertures de l Cyclades PM IPDU Le faire peut causer un feu ou des chocs lect
76. this command This command is available to the admin user only Syntax hwocp lt IPDU gt lt IPDU_ID gt reset Arguments lt IPDU gt IPDU number in a daisy chain lt IPDU_ID gt Identification string previously set by the id command reset turn overcurrent protection off normal operation Chapter 4 Command Line Interface 45 Examples To check the hardware overcurrent status of IPDU 1 enter the following pm gt hwocp 1 IPDU 1 HW overcurrent protection is OFF To reset the hardware overcurrent protection enter the following pm gt hwocp 1 reset IPDU 1 was reset The id command sets or displays the ID of a PM IPDU A maximum of 16 characters not case sensitive is allowed Spaces numbers and special characters are allowed This command is available to the administrator user only This command works in a daisy chain Syntax id lt IPDU gt lt IPDU_ID gt or id lt IPDU_ID gt lt IPDU_ID gt or id Arguments lt IPDU gt IPDU number in a daisy chain lt IPDU_ID gt Identification string previously set by the id command If lt IPDU_ID gt follows lt IPDU gt or if the lt IPDU_ID gt parameter is typed twice the latest entry of the lt IPDU_ID gt parameter updates the ID string no argument Displays the IDs of all PM IPDUs in the daisy chain Examples To set the ID of PM IPDU 1 R amp D enter the following pm gt id 1 R amp D IPDU 1 id R amp D 46 Cyclades PM IPDU Ins
77. w control 22 Cyclades PM IPDU Installer Administrator User Guide To log into the PM IPDU through the console IN port From your terminal emulation application log into the console port as admin AlterPath PM Copyright c 2002 2006 Avocent Corporation V 1 9 0 Jun 21 2006 PM IPDU 1 PM OUT 10 Username admin The default password is pm8 If the password has been changed from the default use the new password If this is a first time installation see Initial Configuration Using the Command Prompt on page 24 for instructions on changing the default password adding users and assigning outlets to users See Command Line Interface on page 31 for procedures on logging in and using the console commands to manage power on connected devices 23 Configuration The Cyclades PM IPDU may be configured by any one of three methods e Command Prompt Full configuration capabilities e Browser Available only when the PM IPDU is connected directly to an AUX port on a KVM switch or OnSite appliance or connected directly to a serial console port on an ACS console server TS terminal server or OnSite appliance This menu allows you to invoke the various PM IPDU operations such as cycling switching on switching off and basic configurations of the power management session to communicate with the PM IPDU Only a limited number of parameters may actually be changed and saved to the PM IPDU e Text based menu Available on
78. wer Supply ER N wo gt qa o N oo o o x x N E zx d a o si oo En o N re Circuit Breakers Figure C 4 PM20i L30A IPDU PM20i 32A IPDU and PM20i 32Au IPDU Circuit Breakers PM20i 32A IPDU and PM20i 32Au IPDU The PM20i 32A IPDU and the PM20i 32Au IPDU have two 16 amp circuit breakers The first circuit breaker controls outlets 11 through 20 the second controls outlets 1 through 10 In the event that the total current flow to outlets 11 through 20 exceeds 16 amps due to equipment connected to these outlets then the first circuit breaker will trip causing outlets 11 through 20 to shutdown This does not affect outlets 1 through 10 which are controlled by the second circuit breaker As the PM20i 32A IPDU and the PM20i 32Au IPDU have the controller powered from the line side of one of the circuit breakers the whole unit will become inoperative only when both circuit breakers trip however the controller will remain functioning When either circuit breaker trips only the power outlets of that segment will be affected and half of the outlets remain operative Appendices 83 Circuit Breaker Trip Time Depending on the model the Cyclades PM IPDU uses either one 10 amp one 20 amp two 15 amp or two 16 amp circuit breakers The following table shows the circuit breaker trip time for all PM IPDU models Table C 1 Circuit Breaker Trip Time Current Load Trip Time
79. wing features e One of the following power plugs e 125VAC ISA power plug NEMA 5 15P e 125VAC 20A power plug NEMA 5 20P e 125VAC 20A power plug NEMA L5 20P e 125VAC 30A power plug NEMA L5 30P e Ten 125VAC 15A power receptacles NEMA 5 15R e 125VAC 15A 20A two 15A circuit breakers Horizontal mounting 1U 10 NEMA5 15R Power Outlets IN Port Y OUT Port Digital Current Display Figure 1 6 Cyclades PM10 IPDU Chapter 1 Introduction 9 Cyclades PM10i IPDU The Cyclades PM101 IPDU has the following features e One of the following power plugs e 240VAC 10A power plug IEC320 C14 e 240VAC 16A power plug IEC320 C20 e Ten 240VAC 10A power receptacles IEC320 C13 e 240VAC 10A 20A supplementary protector e Horizontal 1U mounting 10 IEC320 C13 Power Outlets IN Port O zz NA ANA A AA ga O Ea Sess BE ROSAS II AS Eli o OUT Port IEC320 C14 Power Inlet Figure 1 7 Back of the Cyclades PM10iIPDU AlterPath O 0 1 3 3 4 5 8 7 8 9 10 Power Outlet LEDs Digital Current Display Figure 1 8 Front of the Cyclades PM10ilPDU C
80. yclades PM IPDU s surrounding humidity and the maximum humidity the IPDU has registered humidity peak It may also be used to clear the saved peak humidity value This command only works on PM IPDU models with a humidity sensor Syntax humidity lt IPDU gt lt IPDU_ID gt reset 44 Cyclades PM IPDU Installer Administrator User Guide Arguments lt IPDU gt IPDU number in a daisy chain lt IPDU_ID gt Identification string previously set by the id command reset Resets the maximum humidity registered Examples To get the humidity for all units in a daisy chain enter the following pm gt humidity IPDU 1 humidity 42 3 Maximum 58 7 IPDU 2 humidity 44 0 Maximum 72 6 IPDU 3 Does not have humidity sensor To get the humidity for specific unit provide the unit number as an argument enter the following pm gt humidity 2 IPDU 2 humidity 44 0 Maximum 72 6 To reset the maximum humidity registered use reset as a argument enter the following pm gt humidity reset IPDU 1 Clearing maximum recorded humidity to zero IPDU 2 Clearing maximum recorded humidity to zero hwocp The hwocp command checks the status of the hardware overcurrent protection When overcurrent protection is on the power is shut off When the overcurrent protection is off or reset the power is on and the PM IPDU is running in normal mode If no string identifying the IPDU is given all PM IPDUs in the daisy chain are affected by
81. yclades PM10i L30A IPDU The Cyclades PM10i L30A IPDU has the following features e 30A input power cord L6 30P plug USA model e Ten 240VAC 10A power receptacles IEC320 C13 e Two 240VAC 15A magnetic circuit breakers with press to reset function Horizontal 1U mounting Refer to Figure 1 7 on page 9 and Figure 1 8 on page 9 for images of the Cyclades PM10i L30A IPDU Cyclades PM10i 32A IPDU The Cyclades PM10i 32A IPDU has the following features e 32A input power cord IEC 309 plug e Ten 240VAC IOA power receptacles IEC320 C13 e Two 240VAC 16A magnetic circuit breakers with accidental off protection function 10 Cyclades PM IPDU Installer Administrator User Guide Horizontal 1U mounting Refer to Figure 1 7 on page 9 and Figure 1 8 on page 9 for images of the Cyclades PM10i 32A IPDU Cyclades PM10i 32Au IPDU The Cyclades PM10i 32Au IPDU has the following features 32A unterminated input power cord Ten 240VAC 10A power receptacles IEC320 C13 Two 240VAC 16A magnetic circuit breakers with accidental off protection function Horizontal 1U mounting Refer to Figure 1 7 on page 9 and Figure 1 8 on page 9 for images of the Cyclades PM10i 32Au IPDU Cyclades PM20 IPDU The Cyclades PM20 IPDU is available in three models PM20 15A IPDU PM20 20A IPDU and PM20 30A IPDU Each model has the following features Figure 1 9 The Cyclades PM20 IPDU One of the following power plugs e 125VAC ISA power plug NEMA
82. ync pm gt Synchronizing user database in IPDU 2 deluser 39 The deluser command deletes one username from the internal database This command is available to the admin user only Syntax deluser lt user gt Arguments lt user gt Desired username 40 Cyclades PM IPDU Installer Administrator User Guide Examples To delete the user rog enter the following pm gt deluser rog Username deleted display The display command allows logical inversion of the 2 digit 7 segment display The purpose of this command is to allow a PM IPDU to be mounted upside down This command is available to the admin user only NOTE The decimal point will be at the top of the display when the PM IPDU is mounted upside down Syntax display lt IPDU gt lt IPDU_ID gt 0 180 or display Arguments no argument show display status of all PM IPDUs in the daisy chain lt IPDU gt number of the PM IPDU in the chain lt IPDU_ID gt Identification string previously set by the id command 0 normal mode default 180 inverted display Examples To set the display if IPDU 2 to inverted mode enter the following pm gt display 2 180 IPDU 2 Display mode set to 180 degrees rotated To set the display of IPDU 1 to normal mode enter the following pm gt display 1 0 IPDU 1 Display mode set to normal Chapter 4 Command Line Interface 41 To view the display status enter the following pm gt display IPDU 1 Display
Download Pdf Manuals