Home

Cooper Lighting FUS12 User's Manual

image

Contents

1. Tube 34W 3 13W Twin Tube 51W 1 20W T12 Fluorescent 32W 2 20W T12 Fluorescents 53W 3 20W T12 Fluorescents 85W 1 40W Biaxial Fluorescent 45W 2 40W Biaxial Fluorescents 82W ES Ballasts amp STD Lamps 1 17W T8 Fluorescent 23W 2 17W T8 Fluorescents 45W 3 17W T8 Fluorescents 68W 1 32W T8 Fluorescent 37W 2 32W T8 Fluorescents 71W 3 32W T8 Fluorescents 108W 1 40W T12 Fluorescent 50W 2 40W T12 Fluorescents 86W 3 40W T12 Fluorescents 136W ES Ballasts amp ES Lamps 1 40W T12 Fluorescent 44W 2 40W T12 Fluorescents 76W 3 40W T12 Fluorescents 120W Electronic Ballast Data Consult Factory of Camcar Division of Textron Inc Poo COOPER Lighting www cooperlighting com Specifications and Dimensions subject to change without notice Consult your representative for additional options and finishes ADC041624 03 29 2007 8 40 27 AM PHOTOMETRICS FUS12 Candlepower Distribution Candlepo wer Zonal Lumen Summary Test No ITL32079 Deg L lI Zone Lumens Lamp Luminaire 0 1589 1589 0 30 1248 19 8 34 4 FUS S16 240 5 1582 1592 0 40 2032 32 2 56 0 Lamp 2 F40T12 CW 35 1543 1541 0 60 3234 51 3 89 2 Lumens 3150 aa 25 1456 1421 0 90 3626 57 6 100 0 Spacing Criteria 35 1279 1224 90 180 0 0 0 0 0 eel a 6 45 951 926 0 180 3626 57 6 100 0 55 567 587 65 270 295 75 107 113 85 15 17 eee 90 0 0 ms l Coeffici
2. DESCRIPTION The Fail Safe FUS Series combines maximum security construction features with energy saving technology This surface mounted luminaire utilizes a one piece clamshell housing security lensing and tamper resistant fasteners to maximize impact resistance and prevent contraband concealment and unauthorized fixture penetration U L listed and C S A certified for damp locations The FUS Series is ideal for confinement security applications Suitable for use in inmate cells psychiatric wards secure corridors and general population areas SPECIFICATION FEATURES A Lens To be specified Choice of prismatic acrylic prismatic polycarbonate or prismatic tempered glass on fixture side clear polycarbonate or clear tempered glass on environmental side See Lens Options B Fasteners Stainless steel tamper resistant TORX screws with center pin reject are standard Allen head screws with center pin reject optional C Housing Clamshell design combines die formed 12 ga 14 ga or 16 ga CRS body with continuous welded and ground ends to form a one piece Housing Cont seamless doorless housing which maximizes impact resistance and prevents contraband concealment and unauthorized fixture penetration Standard white high reflectance polyester powder coat finish Gloss 85 Reflectance 93 Hardness 2H Salt Spray 500 Hours D Lamps By Others E Lens Retention Lens secured by t
3. ent of Utilization rc 80 70 50 30 10 0 rw 70 50 30 10 50 30 10 50 10 50 10 50 10 0 RCR 0 69 69 69 69 67 67 67 64 64 61 61 59 59 58 o 1 64 62 60 58 61 59 57 58 55 56 54 54 52 51 2 59 56 52 50 55 52 49 53 48 51 47 49 46 45 3 55 50 46 43 49 46 43 48 42 46 41 45 41 40 4 51 45 41 38 44 40 37 43 37 42 36 41 36 35 o 5 47 40 36 33 40 36 32 39 32 38 32 37 31 30 6 44 37 32 29 36 32 29 35 28 34 28 33 28 27 7 40 33 28 25 33 28 25 32 25 31 25 30 25 24 8 37 30 25 22 29 25 22 29 22 28 22 27 22 21 9 34 27 22 19 26 22 19 26 19 25 19 25 19 18 10 32 24 20 17 24 20 17 24 17 23 17 22 17 16 rc Ceiling reflectance rw Wall reflectance RCR Room cavity ratio CU Data Based on 20 Effective Floor Cavity Reflectance ORDERING INFORMATION SAMPLE NUMBER FUS S12 313 277 82 96 EBT2 Product Steel Fixture Family Gauge Width Lamp Type Voltage Lens Type Ballast Options FUS UlItimax Surface Luminaire S 12 ga Ultimax X 14 ga Maximum D 16 ga Medium N 18 ga Minimum 12 12 Wide ae COOPER Lighting www cooperlighting com o 1 Nom Length Compact Fluorescents 113 1 13W Lamp 126 1 26W Lamp 213 2 13W Lamps 226 2 26W Lamps 313 3 13W Lamps 2 Nom Length T8 Fluorescents 117 1 17W Lamp 217 2 17W Lamps 317 3 17W Lamps T12 Fluorescents2 120 1 20W Lamp 220 2 20W Lamps 320 3 20W Lamps Biaxial Fluorescents 140BX 1 40W Lamp 240BX 2 40W Lamps 4 Nom Length T8 Fluorescent
4. ferent circuit outlet 1For specific electronic ballast specify brand and catalog number 2Electronic ballast not available for F20T12 lamps 3Products also available in non US voltages and 50Hz for international markets Consult your Cooper Lighting Representative for availability and ordering information 4For use with Compact Fluorescent Biaxial and 20W T12 lamps 5For additonal information about the TCS option see Fail Safe spec sheet for TCS Touch Control System ADC030025 or pages 1106 and 1107 in the 4th Edition of the Cooper Lighting Buyer s Guide Specifications and Dimensions subject to change without notice Fail Safe e Customer First Center 1121 Highway 74 South Peachtree City GA 30269 e TEL 770 486 4800 FAX 770 486 4801 CPH Continuous Concealed Piano Hinge EBP Emergency Battery Pack FNL Fluorescent Night Light Lamp by others LNL LED Night Light 50 000 hrs provided by Cooper GLR Fuse and Holder RIF Radio Interference Filter SPK Speaker Housing Compartment extends housing WL Wet Label Auto Control Modules ACM FNL for FNL On Off Switches TCS Touch Control System Stainless Steel Housing SSN Natural Brushed Finish SSP Polyester Powder Coat Finish Fasteners SF3 Allen Head center pin reject Accessories 9306 Allen Head Wrench VRSD TORX Head Vandal Resistant Screwdriver ADC041624 03 29 2007 8 40 27 AM
5. hru studs and vertically adjustable internal CRS hold downs Catalog Project Prepared by F Hinge Internal Security Hinge leaves no exposed parts for weapon fabrication and facilitates maintenance G Backplate Die formed CRS backplate forms an irretrievable blade trap to prevent contraband concealment gauge to match housing H Ballast Standard Class P CBM ETL ballast Labels U L listed C S A certified standard damp label optional wet label LAMP CONFIGURATIONS 4 11 16 119mm 23 8 23 8 60mm 60mm 1 1 2 1 1 2 38mm 38mm 344mm MOUNTING DIMENSIONS 4 9 16 x 1 14mm x 25mm Mtg Holes 2 1 4 57mm ae wt Dia Access Hole 203mm _ 13 9 16 344mm 8 203mm 12 1 4 311mm 4 9 16 x 1 14mm x 25mm Mtg Holes ess 386mm 386mm 50 1 8 1273mm assas sae o 5316 __ 386mm 5 127mm 13 9 16 4 9 16 x 1 14mm x 25mm Mta Hol 2 1 4 57mm Dia Atg Holes Access Hole _F 8 203mm 13 9 16 344mm y L gare 26 5 16 668mm 2 1 4 57mm Dia Access Hole 8 203mm 13 9 16 344mm TORX is a registered trademark FAIL SAFE FUS12 13W 120W Fluorescent ULTIMAX SURFACE LUMINAIRE ENERGY DATA Input Watts STD Ballasts amp STD Lamps 1 13W Twin Tube 17W 2 13W Twin
6. s 132 1 32W Lamp 232 2 32W Lamps 332 3 32W Lamps T12 Fluorescents 140 1 40W Lamp 240 2 40W Lamps 340 3 40W Lamps 120 120V 277 277V Inner Layer Optional 90 005 UV Absorbing Overlay Fixture Side 80 125 Prismatic Acrylic 81 156 Prismatic Polycarbonate 82 187 Prismatic Polycarbonate 93 156 Prismatic Tempered Glass Notes Environmental Side 84 125 Clear Polycarbonate 85 187 Clear Polycarbonate 86 250 Clear Polycarbonate 87 375 Clear Polycarbonate 88 500 Clear Polycarbonate 94 187 Clear Tempered Glass 96 250 Clear Tempered Glass 97 375 Clear Tempered Glass 98 500 Clear Tempered Glass Blank Magnetic Ballast Standard 4 LEOC8 T8 Energy Saving Ballast LE3 40W T12 Energy Saving Ballast Electronic Ballast EBT1 1 Ballast for use with Compact Fluorescent Lamp EBT2 2 Ballasts for use with Compact Fluorescent Lamp EB81 1 Ballast for use with T8 Lamp EB82 2 Ballasts for use with T8 Lamp EB21 1 Ballast for use with T12 Lamp2 EB22 2 Ballasts for use with T12 Lamp2 EBX1 1 Ballast for use with Biaxial Lamp EBX2 2 Ballasts for use with Biaxial Lamp For additional options consult Cooper Lighting Representative Specifications and Dimensions subject to change without notice Electronic ballast may cause interference with other electronic devices If interference occurs move the device away from the product or plug connect into a dif

Download Pdf Manuals

image

Related Search

Related Contents

詳細取扱説明書 - エプソンパートナーズネット  SC400 USER MANUAL - AZ Reinigungstechnik.de  Bury Fusiliers - Warrington Borough Council  Tacens Mars Gaming  NRG Turbine Control Anemometer Digital, PNP, 8.0 m User Manual  Toyota, Lexus, Honda and Proton Vehicle - Snap    Philips SE171 User's Manual  23 et 30 mars 2014  

Copyright © All rights reserved.
Failed to retrieve file