1. For example a linear spread lens or cross baffle can be locked in place COIL SPRING into a desired orientation Please note that not all accessories are compatible with each other and with all lamps CEILING Figure 5 SOCKET ASSY BACK RING PIVOT JOINT FOR GIMBAL TIGHTENING SNOOT Flush Position Regressed Position Figure 8 15 Regressed Lamp Ring Snoot skip to Step 19 if not regressing the lamp The lamp ring may be installed in a regressed position only if a SNOOT accessory is being used See Fig 8 If necessary please see step 13 for instructions on SNOOT installation To accomplish the regressed ANE baho lamp ring position set the COVER RING aside Remove the lamp ring assy by loosening the two 2 SET SCREWS in the GIMBAL BLOCKS A 16 Once loosened the lamp ring assy can be removed by grasping the Figure 6 GIMBAL RING and turning clockwise until it releases from the GIMBAL Cover Ring Removed BLOCKS Printed in USA COOPER Lighting INSTALLATION INSTRUCTIONS V90229 3 Avoid Fire or Electric Shock RSA COMBOLIGHT LAMPHOLDER Page 3 of 3 Installation Instructions for qualified electricians only Install per National Electrical Code and local regulations Read Installation Instructions completely before installation Failure to follow Installation Instructions may void warranties THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PER
2. INSTALLATION INSTRUCTIONS V90229 1N Avoid Fire or Electric Shock RSA COMBOLIGHT TRIMLESS Page 1 of 3 Installation Instructions for qualified electricians only Install per National Electrical Code and local regulations Read Installation Instructions completely before installation Failure to follow Installation Instructions may void warranties FIXTURE MOUNTING 1 First remove TRIMLESS INSERT from Housing by pulling straight out See Fig 1 Fixture must be mounted using either BUTTERFLY MOUNTING BRACKETS or HANGER BARS Contact RSA Dealer for HANGER BARS HOUSING TRIMLESS INSERT Figure 1 INSTALLATION NOTE DO NOT install insulation within 3in of any part of the Luminaire Blinking light of this thermally protected Luminaire may indicate overheating BUTTERFLY MOUNTING 2 Fixture comes equipped with universal BUTTERFLY MOUNTING BRACKETS that can take common 1 or 1 1 2 black iron or galvanized MOUNTING CHANNELS supplied by others See Fig 2 3 Position fixture so the MOUNTING CHANNELS lie on top of the ceiling runners 4 Fasten MOUNTING CHANNELS securely to ceiling runners 5 Secure MOUNTING CHANNELS to universal BUTTERFLY MOUNTING BRACKETS with wire tie downs 6 The BUTTERFLY MOUNTING BRACKETS are height adjustable and should be set so that the APERTURE COLLAR will be flush with the finished ceiling plane MOUNTING CHANNEL BUTTERFLY MOUNTING BRACKET HEX
3. SCREW APERTURE COLLAR Figure 2 ELECTRICAL 7 Remove the JBOX COVER from the JBOX by removing the four SCREWS Connect supply lead wires to junction box lead wires in accordance with your local electrical code s or N E C Replace JBOX COVER onto JBOX securing with SCREWS See Fig 3 TRIMLESS THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED cae COVER Figure 3 CEILING MATERIAL INSTALLATION 8 Aclean square hole in the CEILING MATERIAL must be cut Install the ceiling material below housing as seen in Fig 4 9 Replace the TRIMLESS INSERT into the HOUSING by pushing until flush with the CEILING MATERIAL as seen in Fig 4 Using the OUTER ALIGNMENT HOLES on the TRIMLESS INSERT screw the TRIMLESS INSERT into the HOUSING using DRYWALL SCREWS into the Outer Holes on the TRIMLESS INSERT 10 Smooth out MUDDING COMPOUND TAPE from around aperture to surrounding areas of DRYWALL as seen in Fig 4 OUTER ALIGNMENT HOLES i a ae DRYWALL INSERT MUDDING COMPOUND Figure 4 Printed in USA a COOPER Lightin INSTALLATION INSTRUCTIONS RSA V90229 2 COMBOLIGHT Avoid Fire or Electric Shock c US LAMPHOLDER Page 2 of 3 THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CON
4. SON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED GIMBAL BRACKET Standard Position GIMBAL BRACKET Rotated 180 to Down Position Figure 9 17 Once removed flip the two 2 GIMBAL BRACKETs around 180 and tighten the joint if necessary See Fig 9 If necessary please see Step 21 for gimbal tightening instructions 18 Reinsert the lamp ring assembly by turning it counter clockwise into the SLOTs on the GIMBAL BLOCKS Re tighten the two 2 SET SCREWs in the GIMBAL BLOCKS The lamp ring assy should now be oriented in the up position See Fig 10 GIMBAL RING GIMBAL BLOCK SNOOT SET SCREW Figure 10 Printed in USA 19 To replace the COVER RING Push the COVER RING onto the BACK RING by lining up the BAYONET SLOTS see Fig 11 with the two 2 PINs in the BACK RING PIN BACK RING Figure 11 20 Once lined up push straight back until the COVER RING stops then while keeping the COVER RING pushed back turn clockwise until it pushes forward again slightly See Fig 12 COVER RING Figure 12 AS INSTALLED 21 Gimbal tightening instructions The lamp ring is intended to give positive tension at the PIVOT JOINTS so the lamp ring can be aimed by hand and held in place by tension If a stronger more secure lock is required then the PIVOT JOINTS hex screws may be tightened clockwise with a hex wrench tool See Fig 6 Please note th
5. STRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED Installation Instructions for qualified electricians only Install per National Electrical Code and local regulations Read Installation Instructions completely before installation Failure to follow Installation Instructions may void warranties is 11 Lamp installation To install LAMP remove the COVER RING by pushing straight back on the COVER RING and then turning it counter clockwise to release See Fig 5 OPTICAL ACCESSORY ACCESSORY RETAINER RING 12 Once removed insert the properly specified LAMP into the BACK RING ensure that the LAMP is the correct LAMP for the SOCKET or damage to the fixture or lamp may occur The LAMP will seat into the COIL SPRING when installed properly While holding the LAMP in place grab the SOCKET ASSY and plug or screw the LAMP firmly into it ee Fig 6 BACK RING Figure 7 13 Optical Accessory skip to Step 21 if not using optical accessories To install OPTICAL ACCESSORY pieces remove the ACCESSORY RETAINER RING by unthreading until it is completely removed from the COVER RING 14 Install desired OPTICAL ACCESSORY pieces into the COVER RING and re thread the ACCESSORY RETAINER RING firmly See Fig 7 The COVER RING can accommodate three 3 accessories without the COVER ACCESSORY RETAINER RING or two 2 pieces with it RING The ACCESSORY RETAINER RING may be used to lock the accessory
6. at in some conditions the COVER RING will need to be removed to gain access to the inner PIVOT JOINTS a COOPER Lighting