Home
Cooper Hand Tools 9448ES User's Manual
Contents
1. 0e pr 8000 Keypad shows most recent event Earlier events Later events If the Panic light zone 6 glows then deal with the cause of the alarm first Next reset the panic button then switch the alarm system bells off and reset the system see above TO TEST BELLS Make sure system is unset before starting the test Key in 4 then ENTER followed by your user code The internal sounders will operate for three seconds and then the external sounder and strobe will operate for three seconds TO WALK TEST Key in 5 then ENTER followed by your user code The internal sounder gives a steady tone Open and close the Exit Entry zone and zones 1 to 4 Open and close zone 5 if it is NOT a fire zone and zone 6 if it is NOT a panic button Each time you open a zone the internal sounder gives a pulsing tone You cannot test the Tamper Circuits without creating an alarm condition Similarly a panic button will always cause a full alarm To stop walk test key in your access code TO READ THE LOG The system keeps a log of the last ten alarm or tamper events To read the log key in 8 then ENTER followed by your user code The system switches on the zone or Tamper lights to show you the most recent event If you want to see earlier events then press lt lt the 1 key To see more recent events press gt gt the 3 key The keypad gives a short tone when you reach either end of the log To leave the log pres
2. crite pr c dem ment POUR TESTER LES SIRENES Le syst me doit tre imp rativement l arr t Taper le chiffre 4 sur le clavier puis ENTER suivi de votre code La sir ne int rieure fonctionne pendant 3 secondes La sir ne ext rieure et le flash s il existe se d clenchent leur tour pendant 3 secondes POUR EFFECTUER UN TEST DE PASSAGE Taper le chiffre 5 sur le clavier puis ENTER suivi de votre code A la fin de cette s quence la centrale met un signal sonore continu Ouvrir et fermer la zone Entr e Sortie ainsi que les zones 1 4 faire de m me pour la zone 5 si ce n est PAS une zone incendie et la zone 6 si elle n est PAS quip e d un bouton panique A chaque ouverture de zone la centrale met un son discontinu NOTA vous ne pouvez pas tester les zones d autoprotection ou le bouton panique sans d clencher une alarme r elle Pour arr ter le test en cours tapez de nouveau votre code POUR CONSULTER LA MEMOIRE D EVENE MENTS Le syst me conserve en m moire les dix derniers v nements d alarme intrusion ou d autoprotection Pour consulter ces informations taper le chiffre 8 puis ENTER et votre code La centrale allume le s voyant s correspondant la aux zone s concern es ou l autoprotection pour indiquer l v nement le plus r cent Pour visualiser les v nements plus anciens presser lt lt touche 1 Pour visualiser les v nements plus
3. Mise en marche de la centrale avec isolation temporaire de zones Entr e des commandes de programmation et de mise en marche l arr t D clenchement d une alarme agression par pression simultan e sur les deux touches panique 1 et 3 Si cette fonction est activ e Mise en marche du syst me avec un nombre pr programm de zones isol es D clenchement d un test sir nes et flash D clenchement d un test d tecteurs Permet de modifier le code d acc s utilisateur Active ou d sactive le mode carillon Permet de consulter la m moire d v nements Presser la touche lt lt 1 pour visualiser les v nements les plus anciens et la touche gt gt 3 pour visualiser les plus r cents Centrale d alarme filaire 9448 et 9448ES Guide Utilisateur Scantronic Ltd 2001 Le contenu de ce document a t tabli avec le plus grand soin afin d assurer que les informations qui y figurent soient correctes sauf erreurs ou omissions Cependant ni les auteurs ni Scantronic ne peuvent tre tenus pour responsable de tout dommage ou perte caus s ou relatifs directement ou indirectement cette documentation Le contenu de cette notice est sujet modifications sans avis pr alable Mis en page au Chine 496572 7 Entrer par Aller la le chemin centrale pr vu 88080 Signal sonore discontinu de POUR METTRE EN MARCHE TOTALE Composer sur le clavier le code utilisateur 4 chiffre
4. r cents presser gt gt touche 3 496572 ou Num ro de de code a actuel Suiv du code changer La centrale met Re C Nouveau c fau code 4 chiffres La Perte met 2 bips Le clavier met un signal signal court lorsque la fin ou le d but de la m moire est atteint Pour quitter la consultation de la m moire presser la touche ou POUR CHANGER LE CODE UTILISATEUR Votre centrale poss de deux codes utilisateur distincts chacun compos de 4 chiffres 1234 et 0000 Remplacez imm diatement le code 1234 par un nombre quatre chiffres que vous seul connaissez Vous pouvez utiliser n importe quelle combinaison pour ce nouveau code SAUF 0000 Le code 0000 est inactif et ne permet pas de faire fonctionner le syst me Pour activer le second code remplacer 0000 par un autre nombre quatre chiffres Pour d sactiver celui ci remplacez le de nouveau par 0000 NE PAS utiliser la m me combinaison pour les deux codes Description des zones Zone Entr e Sortie Nom de l installateur N de t l phone jour N de t l phone nuit 496572 11 Part No 496572 Issue 2
5. s lectionn e vous permettant d acc der la centrale A l issue de celle ci il est possible que le syst me ait t programm pour d livrer une alarme sonore int rieure d une dur e de 30 s Au bout de ces 30 secondes la centrale d clenche une alarme totale Entrez votre code afin d annuler cette derni re SI UN VOYANT S ALLUME AU MOMENT DE LA temporisation Zone 1 MISE EN MARCHE de sortie 80800 Recherche du d faut et reprise de la s quence de mise en marche Si durant la mise en marche une signalisation sonore dis continue et un voyant de zone vous indiquent qu un d tecteur quelconque est activ une porte ou une fen tre est peut tre rest e ouverte entrer votre code pour arr ter le signal sonore Retourner dans la zone indiqu e et v rifier le fonctionnement des d tecteurs ou la fermeture des issues Recommencer la mise en service en tapant votre code sur le clavier Si le d faut 496572 R p ter pour chaque zone D Zone 2 N 2000 ga U pr 88000 amp 0 6 Entrez Allez la dans les centrale locaux 8000 Zone Auto protection Agression Tapez le nouveau code utilisateur puis 80000 persiste contacter imm diatement votre installateur Si le voyant entr e sortie est allum il se peut que l issue autoris e soit ouverte Quitter les locaux et fermer la porte Le signal sonore devient alors continu et le syst me se met en marche norm
6. the end of this 30 seconds the system gives a full alarm external sounder Key in your user code to cancel the alarm IF A ZONE LIGHT GLOWS WHILE SET TING If during setting the sounder gives an interrupted tone and a zone light glows then a detector is being triggered maybe a door or window is open Key in your user code to stop the tone Check the indicated zone s and if possible correct the cause of the alarm Try setting the system again If the fault persists call your alarm installer If the Entry Exit light glows the exit door may be open Leave the premises and close the door The interrupted tone should change to a steady tone when the door is closed and the system then sets as normal 496572 3 Repeat for each zone Zone D No amp 88088 fr 0 6 pu 80080 amp amp Enter Go To Control Building Panel 0000 Zone Tamper Panic Reset any panic buttons activated then 8000 TO OMIT A DETECTOR You may need to temporarily set the system with one or more detectors omitted Key in the zone number followed by OMIT for all the zones you want to omit and then key in your user code The system flashes the light s of the omitted zone s during the exit time and then sets Note that you cannot omit a panic or fire zone or the EE zone The system will not raise an alarm if any omitted detector is triggered during this setting cycle The system will reinstate the detector s and se
7. 9448 moie 9448ES USER GUIDE UK HARDWIRED CONTROL PANEL GUIDE UTILISATEUR F CENTRALE D ALARME FILAIRE ETS RAR COOPER Menvier EE English Operator Controls and Displays On both control panel and remote keypad the LEDs display the following functions Glows steadily when mains power is present Shows the state of the entry exit zone Shows the state of detector zones 1 to 6 Glows steadily if the tamper loop is broken Glows when the system is unset flashes when part set The keypad on the control panel and 9427 provide the following keys Used to set the panel with individual zones tempo rarily omitted Used to enter programming and setting unsetting commands Pressing the two PA keys 1 and 3 at the same time starts a PA alarm if this function is enabled in programming Used to set the system with a preprogrammed number of detectors omitted Used to start a test of the sounders and strobe Used to start a test of the detectors Used to change the user access code Used to enable or disable the Chime facility Used to read the 10 event log When reading the log pressing lt lt 1 displays earlier events and gt gt 3 displays later events 9448 and 9448ES Hard Wired Control Panel User Guide Scantronic Ltd 2001 Every effort has been made to ensure that the contents of this book are correct errors and omissions excepted However neither the authors nor Scantronic accept
8. Pour effectuer la remise a z ro de l ensemble cette proc dure est obligatoire avant toute nouvelle utilisation Entrer nouveau votre code Tous les voyants doivent s teindre Le syst me est pr t Alarme incendie elle est caract ris e par un signal sonore deux tons provenant de la sir ne int rieure Quitter les lieux imm diatement et appeller les pompiers Ne retourner dans les locaux que lorsque les conditions de s curit sont r tablies Arr ter le syst me et effectuer une remise z ro en suivant la proc dure indiqu e ci dessus 496572 9 Pas l alarme agression 8808008 10 808008 8008 A 00 om pa D clencher les 8000 Le clavier affiche les v nements les plus d tecteurs oA o e x r cents Ev nements plus anciens Ev nements plus r cents Si celle ci ne peut tre obtenue s assurer que le d tecteur d incendie n est pas rest activ Alarmes autoprotection ou agression si la sir ne int rieure retentit alors que le syst me est l arr t vous devez imm diatement vous rendre la centrale Si le voyant autoprotection est allum arr ter la sir ne en tapant votre code sur le clavier Contacter imm diatement votre installateur Pour arr ter une alarme agression zone 6 suppri mer pr alablement le d faut sur la zone Arr ter ensuite les sir nes et effectuer une remise z ro du syst me se reporter la proc dure d
9. alement POUR ISOLER UN DETECTEUR Il peut tre temporairement n cessaire d isoler un ou plusieurs d tecteurs Pour cela taper le num ro de la zone concern e puis pour toutes les zones que vous souhaitez d sactiver Entrer ensuite votre code Les voyants correspondant aux zones isol es s allument pendant la temporisation de sortie puis le syst me se met en marche II est impossible d isoler une zone agression incendie ou la zone Entr e Sortie Aucune alarme ne se d clenche si un d tecteur isol est activ pendant cette proc dure de mise en marche Le syst me r tablit le s d tecteur s isol s et se met en marche totale la fois suivante POUR ACTIVER OU DESACTIVER LE MODE CARILLON Taper le chiffre 7 puis ENTER suivi de votre code Lorsque le mode carillon est actif la sir ne int rieure met un signal sonore sp cifique lors de l activation des zones concern es L installateur est charg de program mer vos zones carillon ALARME AGRESSION DECENCHEE A PARTIR DU CLAVIER Votre syst me peut tre programm pour vous permet tre de d clencher une alarme Agression partir du clavier demandez votre installateur Si tel est le cas appuyez simultan ment sur les touches 1et 3 pour d clencher cette fonction POUR EFFECTUER UNE REMISE A ZERO Pour arr ter la sir ne entrer votre code La sir ne s arr te et le s voyant s correspondant au x d tecteur s activ s s allume nt
10. any liability for loss or damage caused or alleged to be caused directly or indirectly by this book The contents of this book are subject to change without notice 496572 Enter via Go to designated control panel route 88088 Interrupted Zone x Exit Tone 88088 Investigate cause and restart setting sequence TO FULL SET Key in your four digit user code shown as at left The exit tone starts Leave premises via the designated exit door Exit tone stops after a preset time and the amp light goes dark Your alarm system is SET TO PART SET Your alarm system may have been installed to allow you to have part of the premises set while other area s are off To part set the system key in 2 then ENTER followed by your user code Note that the part set exit tone is usually a buzzer sound but your system may be programmed to silent set While the system is part set the 6 light flashes Note If you enter your user code incorrectly four times in a row then the system will raise a tamper alarm See opposite TO SWITCH OFF Full Set Enter by the designated entry door Entry tone starts Go to control panel Key in your user code System is OFF Part Set Go to control panel Entry tone starts Key in your user code System is OFF Note The system has a preset entry time to allow you to get to the panel When the entry time has elapsed your system may be programmed to give an internal alarm for 30 seconds At
11. s repr sent sur le sch ma gauche par des Un signal sonore retentit durant toute la temporisation de sortie Vous pouvez quitter les locaux pendant ce laps de temps par l issue autoris e Le signal sonore s arr te automatiquement la fin du temps pr programm et le voyant s teint Votre syst me est bien EN SERVICE POUR METTRE EN MARCHE PARTIELLE Votre syst me d alarme a t programm pour que vous puissiez mettre une partie des locaux sous surveillance pendant que les autres zones sont d sactiv es Pour mettre le syst me en marche partielle taper le chiffre 2 puis 1 suivi de votre code Un signal sonore bip est habituellement mis lors de la temporisation de sortie mais votre syst me peut n anmoins tre programm pour une mise en marche silencieuse Lorsque le syst me est en marche partielle le voyant 6 clignote NOTA si vous tapez votre code de mani re incorrecte quatre fois de suite le syst me d clenche alors une alarme d autoprotection Se reporter la page suivante POUR ARRETER LE SYSTEME LORSQUE LE SYSTEME EST EN MARCHE TOTALE Pendant toute la temporisation d entr e un signal sonore se fait entendre Taper sur le clavier votre code 4 chiffres La centrale est hors service LORSQUE LE SYSTEME EST EN MARCHE PARTIELLE Proc der de la m me fa on qu en marche totale NOTA le syst me poss de une temporisation d entr e pr
12. s OMIT or ENTER 496572 5 ou Your Existing Cod Code No Followed sd by The Code to be me Changed Two Ble Biceps t from Sounder The New F Four Digi Code Two Bleeps from Sounder TO CHANGE YOUR USER CODE Your system provides two separate four digit user codes When the system is new the user codes are 1234 and 0000 Change the 1234 user code immediately to a number that only you know The new code can be any four digit code you choose EXCEPT 0000 The 0000 user code is inactive and will not operate the system To activate the second user code change the 0000 to another four digit number To inactivate the second user code again change it back to 0000 DO NOT use the same number for both user codes Zone Descriptions Installer Name Day Tel Night Tel 496572 Fran ais R a 1 6 Pal Commandes et affichages L affichage des fonctions suivantes est obtenu via les LEDS pr sentes sur la centrale et sur le s clavier s d port s Allum en continu pour indiquer que le secteur est pr sent Indique l tat de la zone Entr e Sortie Indique l tat des zones 1 6 Allum en continu lorsque la boucle d autoprotection est ouverte S allume lorsque le syst me est l arr t et clignote lorsqu il est en Marche Partielle Les touches suivantes sont pr sentes sur le clavier de la centrale ainsi que sur le clavier d port 9427
13. t nor mally the next time you set the system TO SWITCH CHIME ON OR OFF Key in 7 then ENTER followed by your user code to switch Chime on or off When Chime is on the internal sounder chimes when the chime zones operate Note that the Installer must program your chime zones KEYPAD PA Your system may be programmed to allow you to start a Panic Alarm from the keypad ask you Installer If so then press keys 1 and 3 together to start a Panic Alarm AFTER AN ALARM To switch the bells off Key in your user code The sounders will stop and the zone light s for the detectors that triggered the alarm will glow Reset system You must reset the system before it can be used again Key in your access code again All the zone lights should go off The system is now ready for use Fire Alarm The fire alarm is a two tone siren note from the internal sounder Leave the building immediately and call the Fire Brigade Do not go back into the building until it is safe to do so Switch the alarm off and reset the system as described above If you have trouble resetting the system make sure that the fire detector is not being trig gered Tamper or Panic Alarm If you hear the internal sounder when the system is off then look at the control panel If the Tamper light glows then key in your user code to stop the sounder Call your alarm installer for service 496572 A 43 80008 Pe 8008 Trigger Detectors Not Panic Alarm 8000