Home
Compaq I+ME ACTIA NetPorty II User's Manual
Contents
1. Techn Support What to do if you have problems 4 1 3 Solutions for NetPorty Il You start PCCANControl but the connection doesn t work correct For parallel port usage it is necessary to have the EPP loader firmware BOOTLOAD H86 in the NetPorty Il Flash EPROM All Porty s are delivered with this loader You have overwrite the delivered EPP Loader by your own firmware In this case it is possible to download the EPP firmware again into the NetPorty Il Flash This software is a Win32 Console Application and runs under Win95 and WinNT How to use Connect your NetPorty Il with one serial port If you do not use COMI please change it into the file L BAT Start L BAT If you get an error messages like BSL no response from the target hardware it is possible that you have used the wrong COM port Ifyou get the message below COMx Loading bootload h86 Ready without any error message in the next line all activities are correct finished Leave the software with pressing the ESC key sometimes Alt X does not work Info The program LDFSER EXE is a loader that burns firmware in the Porty Flash and also it is a serial monitor The serial parameter are 115200 8 n 1 I ME also can deliver a loader to start firmware in the RAM and a little firmware demo Keil C Please contact us if you want to develop your own firmware oe 1 03 L VIE Troubleshooting amp Techn Support What to do if you have problems T
2. Users Manual NetPorty Il ME ina Systems Supper amp More Welcome to ME ACTIA Before acquainting you with your new I ME Hardware we would first like to thank you for purchasing our product We are extremely pleased that you have chosen to place your trust in ME ACTIA and will do our best to satisfy whatever needs you may have The following is a brief explanation highlighting our background areas of expertise and general product lines This products and the list of our world wide branch offices show that you have found a competent partner in ME ACTIA Since its foundation in 1986 ME ACTIA has made quite a name for itself Our employees are dedicated to producing high quality solutions in the field bus and multiplexed systems sectors The knowledge of our experts allows to develop a spectrum of products which have been used in the automotive field as well as in general industrial environments Our products can be used in all phases of system development system definition prototyping evaluation and field application pplication Foti Dwbudi L AVIE Informatik und MikroEiektronik Whether your professional background is into industry process control or development and test tools we offer six product groups to fulfill your sophisticated needs Tried and tested under the most severe conditions the automotive industry has to offer our products have proved themselves again and again Our
3. sometimes Alt X does not work Info The program LDFSER EXE is a loader that burns firmware in the Porty Flash and also it is a serial monitor to display firmware print outs The serial parameter are 115200 8 n 1 I ME also can deliver a loader to start firmware in the RAM and a little firmware demo Keil C Please contact us if you want to develop your own firmware Zonen 1 03 L VIE The technical components there specifications and the way they work together 3 Hardware Hardware Micro controller 3 1 Micro controller The ME NetPorty Il includes the 16 bit Siemens 80C165 micro controller on a piggy back The controller s clock frequency is 36 84MHz The following recourses are used Port 2 14 EX6IN SJA1000 Port 2 15 EX7IN 82527 16CS550 CS0 CS1 Memory CS2 CS3 Protocol interface CS4 LED latch nl 1 03 L VIE Hardware Memory 3 2 Memory The ME NetPorty Il is equipped with Flash CSO 128 KByte x 8 bit SRAM CS1 512 KByte x 16 bit Optional it can be equipped with Flash 512 KByte x 8 bit and RAM 128 Kbyte x 16 bit 3 2 1 NetPorty Il internal buffers To avoid lost data CAN is faster than the communication channels to the PC the transfer objects are buffered in the NetPorty Il The biggest buffer is between CAN reception and the communication channel to the PC 448kByte If you have many traffic on the CAN bus and the buffer is full it takes a time of several m
4. Output Serial DSR 25 Input Serial Free input as serial master it can be used as CD or RI and also optional power input source Version 1 03 i ir L VIE Hardware Connector 3 6 3 Cable set for serial connection Cable length 30cm 25 pin female 9 pin female Signal 23 1 CD 20 2 Rx 19 3 Tx 16 4 DTR 18 5 GND 24 6 DSR 21 7 RTS 22 8 CTS 25 9 RI L AMIE Version 10 Hardware Connector 3 6 4 Power Supply The NetPorty Il can be powered by an external power supply Therefore the connector is specified for the power supply jack below _ O The power connector is a DC3 5 1 3 mm type That means the internal diameter is 1 3mm 8 5mm hr min 9 0mm Figure 3 3 Power Connector for NetPorty Il um 1 03 L VIE Common problems and how to solve them How to get in touch with our after sales support experts if you so desire 4 Troubleshooting amp Techn Support Troubleshooting amp Techn Support What to do if you have problems 4 1 What to do if you have problems First and foremost please read Installation very closely and make sure that you performed your installation exactly as described For developers The Key is often used in developing environments in combination with the API and or DLL If the PcCANControl software is functioning properly then there is no problem with general CAN access You should
5. customer specific problems We offer CAN CAL workshops and in house seminars to enable CAN users to benefit from I ME ACTIA s extensive knowledge 6 Automotive Diagnostics Assistance during the development phases Diagnostic tools for quality control in production lines as well as after sales diagnostic control and servicing tools are provided to manufacturers suppliers and dealers of the car industry by I ME ACTIA If you have any questions concerning our products or you look for specific solutions within our product groups don t hesitate to call us and benefit from I ME s extensive knowledge your need is our desire Our merger with the french corporation ACTIA in 1995 allowed us to become a powerful supplier for the European automotive industry ACTIA products include diagnostic systems for automotive service and maintenance as well as development and production of high quality on board electronics joining forces with ACTIA has enabled I ME to better service it s international customers not only in Europe but throughout the world Headquarter Office Stuttgart I ME ACTIA GmbH I ME ACTIA GmbH Rebenring 33 Zettachring 4 1 0G 38106 Braunschweig 70567 Stuttgart Germany Germany T 49 531 38701 0 T 49 711 72874 45 F 49 531 38701 88 F 49 711 72874 46 LME WORLDWIDE REPRESENTATIVES 4 NOHAU ELEK AB W A SL ME NOHAU UK LTD N INDUSTRADE AG AiXIA SA ACTIA SA n SANKO v ACTIA I
6. Windows will not launch after the installation of the client and services Make sure that there is a memory area reserved in the SYSTEM INI file The selected memory area is not free or the selected interrupt is being used by another application Refer to Installation The acknowledge sound after inserting or removing the Key is sounded twice There are two services installed on your system One can be found in the CONFIG SYS and the other in the device manager In the device manager under the topic PCMCIA you can disable one of the services The Key is not inserted and PcCANControl starts with the message I ME CARD not available or drive not ready Insert the Key cm 1 03 L VIE Troubleshooting amp Techn Support What to do if you have problems The Key is inserted and PCCANControl starts with the message I ME CARD not available or drive not ready Some aspect of the resource allocation is wrong Refer to Installation for more information 1 1 1 Non Supported PCMCIA Drives In the current version there are some PCMCIA drives which are incompatible with the PCMCIA Key Today as a general rule some PCI connected drives result in compatibility problems The following is a list of known incompatible drives and any laptops which are known to use these drives Drive Known Laptops Using Drive Cirrus Logic SIEMENS NIXDORF Scenic Mobile 700 PCIC compatible COMPAQ Armada LE Version gt Troubleshooting amp
7. selection box then press Start Installation If the file is started com file follow the steps on the screen If necessay type in the password 5 f password is correct software will be installed successful AON Application installation 1 Insert the CD The setup programm will start automatic if not please start the program START EXE in root path Go to Software Installation Choose your operating system is important Choose PcCANControl component at the selection box then press Start Installation If the file is started com file follow the steps on the screen If necessay type in the password 5 Start PcCANControl select create a new project and the NetPorty Il hardware at this case Porty2 COM1 or Porty2 COM2 After the selection the necessary NetPorty Il software is activated on your PC For further information see also chapter about PcCANControl AON It is not necessary to install a driver The software works with the standard Win32 serial communication services with 115200bps 8 bits no parity 1 stop bit si 1 03 L VIE Installation Installing the Software Problems It is possible you chose an incorrect COM port Start PcCANControl again and choose an other COM port 2 3 2 If you start at parallel port 1 Make sure that your PC parallel port uses the EPP mode You have to control it under BIOS setup In this version the NetPorty Il supported the EPP version
8. 000 the Output Control Register must be set to OxFA To connect the second CAN channel or the ISO 9141 channel an optional physical line driver have to be ordered 3 5 Optical interface State of LED during download firmware At serial download no fixed state At parallel download LED 1 green LED 2 green flashing State of LED during work Color LED 1 LED 2 LED 3 Red Bus off green Life cycle flash Flashing during Bus on RS232 Parallel data transfer 1 Life cycle flash 2 Data transfer 3 BUS on off L ME Version gt Hardware Connector 3 6 Connector 3 6 1 9pol sub min D male 3 6 1 1 1 CAN Channel The CAN connector is based on the CiA standard if only one CAN channel is used It is a 9pol sub min D male connector sub min D male CIA pinning CAN_GND CAN_SHIELD CAN L POWER_GND CAN H POWER V 7 32 V Figure 3 1 Standard CAN Connector Pins 1 4 and 8 are not used by NetPorty II a 1 03 L ME Hardware Connector Pin Signal Description i ie miconeded Ea CANL L CAN_L bus line dominant low L bus line dominant low EI GND CAN bus Ine dominant om ground connected on the cable shield ne not con not connected si EN NER SHIELD EIU NN ground connected on the cable shield E POWER GND power supply input ground CAN H CAN H bus line dominant icm EACE PO
9. 7 are used as additional signal line In case of standard version the ports are protected Le ME Version E Hardware Connector 3 6 2 25pol sub min D male To connect the NetPorty Il with the PC it is possible to use the Centronics LPT port directly or to use the adapter cable to use the RS232 COM port In both cases the pinning of the 25pol sub min D male is the same Connector definition Pin VO Usage Description 1 Input Parallel Strobe 2 Input Parallel DO 3 Input Parallel D1 4 Input Parallel D2 5 Input Parallel D3 6 Input Parallel D4 7 Input Parallel D5 8 Input Parallel D6 9 Input Parallel D7 10 Output Parallel acknlg 11 Output Parallel Busy 12 Output Parallel Paper empty 13 Output Parallel Slct 14 Input Parallel autofd 15 Output Parallel error 16 Input Both high gt RESET low gt Operational init DTR Porty RESET in switch level 2 5V input range 40 40V low speed 10ms A weak pull up and pull down is necessary to define with special mounting whether the reset line is active or not if this line is not connected 17 Input Parallel slct in 18 X Both Ground 19 Input Serial TX PC gt Porty 20 Output Serial RX Porty gt PC 21 Input Serial RTS 22 Output Serial CTS 23 Input Serial Free input DTR 24
10. NC x I ME ACTIA Representatives SI KWADRAAT Nuenen Netherlands T 31 40 2631185 F 31 40 2838092 NOHAU ELEK AB Malm Sweden T 46 40 592200 F 46 40 592229 ACTIA SA Toulouse France T 33 05 61176161 F 33 05 61554231 ACTIA INC Bedford Texas USA T 1 817 5710435 F 1 817 3559513 If needed please contact our associates below ATAL SPOL SRO Tabor Czech Rep T 420 361 251791 F 420 361 23043 ATON SYSTEMS SA France T 83 01 42071800 F 33 01 42078555 VIDEOBUS SA Madrid Spain T 34 1 5001950 F 34 1 5000607 ACTIA DO BRASIL Porte Alegre Brazil T 55 51 9699802 F 55 51 3411989 ACVIBUS SA Mexico T 525 368 6169 F 525 368 5646 4 da w N gt Manual NetPorty Il Contents Introduction 1 1 Your I ME NetPorty Il ii 1 2 System Requirements i 1 4 Delivery Contents ner nee nees 1 5 1 3 1 standard ert enis 1 5 1 9 2 Supplementary Support 1 5 Technical SpecificatioNS eeaeee 1 6 Installation seen 2 1 TII EE 2 2 Installing the Hardware 2 2 Installing the Software en 2 4 2 3 1 If you start at serial port 2 4 2 3 2 If you start at parallel port 2 5 HardWare 3 1 Micro controller nennen 3 2 M
11. OMO TES 3 3 3 2 1 NetPorty Il internal buffers 3 3 Protocol Interface sssssss 3 4 Physical Interface nennen 3 5 Optical interface i 3 5 LOT Jua Toe Ar 3 6 3 6 1 9pol sub min D male 3 6 3 6 1 1 1 CAN Channel 3 6 3 6 1 2 More than 1 CAN Channel 3 8 3 6 2 X 25pol sub min D male 3 10 3 6 3 Cable set for serial connection 3 11 3 6 4 Power Supply sess 3 12 Troubleshooting amp Techn Support 4 1 What to do if you have problems 4 2 4 1 1 Solutions for all parts 4 3 4 1 2 Solutions for PCMCIA 4 4 1 1 1 Non Supported PCMCIA Drives 4 5 4 1 8 Solutions for NetPorty ll 4 6 5 Glossary ricavo aiar 5 1 6 Literature esee 6 1 A LevelX API B LevelX Demos C PcCANControl Administration of Document Document version 1 05 Your I ME NetPorty Il Overview Systemrequirements Delivery contents and s o 1 Introduction Introduction Your I ME NetPorty Il 1 1 Your I ME NetPorty Il The NetPorty Il is an improved portable network adapter It is designed to connect devices with RS232 or Centronics interface to the CAN bus With its features it is an ideal general purpose hardware fo
12. WER V power supply input 7 32V The power input and the CAN lines are galvanic disconnect with a limit to 50V There is an internal transzorb diode to limit the disconnect voltage If you don t need a galvanic disconnect the pin 6 can be connected to pin 3 or 5 The POWER GND pin 6 is not connected with the CiA standard bus in every system If the tool does not work pin 6 could have to get connected to the power supply ground L ME Version Hardware Connector 3 6 1 2 More than 1 CAN Channel The pinning is different if more than one CAN channel is used sub min D male multi channel CAN_GND CAN 2 RXO or UART Rx CAN_ SHIELD CAN L Uni i O POWER_GND CAN H POWER V 7 32 V CAN_2 TXO or UART Tx Figure 3 2 Pinning for more than 1 CAN channel a 1 03 VIE Hardware Connector Pin Signal Desi EN Uni Out2 Connected to Port 6 7 2 CANL L CAN_L bus line dominant low L bus line dominant low connected on the cable shield Rx or CAN2 RX 5 CAN SHIELD CAN ground connected on the cable shield 6 POWER GND power supply input ground CAN_H bus line dominant high aw een Tx or CAN2 TX 9 POWER_V power supply input 7 32V Pin 1 4 and 8 are used to provide the additional signals for the second CAN channel or the UART In standard version the inputs are protected Port 6 5 Port 6 6 and Port 6
13. check your usage of the API of DLL If the PcCANControl software is not functioning please consult the list of common problems below and their possible solutions u 1 03 L VIE Troubleshooting amp Techn Support What to do if you have problems 4 1 1 Solutions for all parts The system crashes after choose the hardware at PcCANControl The selected memory area is not free or the selected interrupt is being used by another application Make sure that no conflicts exist on your system If you get a blue screen under Win NT it is most likely that a memory or IRQ conflict is occur PcCANControl launches correctly but CAN access is not possible Check the transceiver cable and CAN connectors If a connector is not correctly plugged connect it right If the sub min D connectors at the end of the cables are hot remove the Key and call I ME If you use higher baudrates remember to protect the end of line with resistors 1200hm Le ME Version DE Troubleshooting amp Techn Support What to do if you have problems 4 1 2 Solutions for PCMCIA The system crashes after the installation of the Key client The selected memory area is not free or the selected interrupt is being used by another application Refer to Installation The system crashes when the Key is inserted or removed The selected memory area is not free or the selected interrupt is being used by another application Refer to Installation
14. he NetPorty Il doesn t work under parallel port Use the right EPP mode on BIOS It can be only one of the EPP modes work with one Win System together In past we find out that EPP 1 7 is necessary for Win9x and EPP 1 9 is necessary for Win NT Please try out the right mode Using a printer and NetPorty Il under Win NT If you use NetPorty Il under NT note that you are not able to print Using a printer and NetPorty Il under Win 9x If you use NetPorty Il under Win9x the normal printer driver is active but it can make problems while printing with the active driver One way to solve this problem is to load the firmware into the flash of the NetPorty Il L ME Version ps Troubleshooting amp Techn Support What to do if you have problems If you encounter difficulties which are not discussed in the manual or if you need more help than is offered in Installation and Troubleshooting please call our after sales service Our experts will do their best to solve whatever problem you might have Hua 1 03 L VIE For better understanding 5 Glossary Glossary Glossary Adapter A piece of hardware which contains one or more PCMCIA sockets The Adapter contains the interface between the Socket Controller and the Host System AUTOEXEC BAT A set of commands in the form of a batch file program that are automatically executed by DOS to help configure your system when you Boot Up your computer BIOS An abbre
15. ical Interface 80C165 36 84MHz 1 x SJA1000 16 MHz 1 x 82527 16MHz 1x UART CAN according to ISO 11898 PCA 820251 Memory 512 x 16 KByte RAM 128 x 8 KByte Flash Temperature Range 0 55 C Connector 9pin sub min D CAN according to CiA DS 102 Housing plastic protection class IP30 Display 3 DUO LED Dimensions 95 5 mm x 41 mm x 20 mm Power Supply 7 32 V DC external power supply jack or via CAN bus connector typically max 500 mA at 7 V DC with physical interface PCA 82C251 oe 1 03 L VIE Introduction Technical Specifications Options Memory 64 KB EPROM instead of flash Physical interface ISO Low Speed ISO 11519 Diagnosis Channel ISO 9141 physical interface CAN CAN optional galvanic disconnect Cable 1 m Cable for adaptation Power supply 230 V AC to regulated 8 V DC 110 V AC to regulated 8 V DC Firmware Individual firmware on request Le ME Version 108 Installing your NetPorty Il Step by step installation procedures for hardware and software 2 Installation Installation Overview 2 1 Overview This chapter gives detailed information about installing the NetPorty Il hardware and about the necessary software drivers which make NetPorty Il access possible The NetPorty Il is delivered with access driver and applications for Windows 95 and Windows NT To get your NetPorty Il operational follow the installation guide lines 2 2 Installing the Hardware To install the ha
16. inutes to transfer the data to the PC You can control this with the 2nd NetPorty Il LED that blinks faster while the data transfer Le ME Version CE Hardware Protocol Interface 3 3 Protocol Interface The product has two CAN protocol chips at a frequency of 16 MHz The SJA1000 chip is connected to the 9 pin D SUB connector with the CiA pinning The optional 82527 is also connected to the 9 pin D Sub connector without physical line driver The C165 uses the CS2 signal to select the SJA1000 The NetPorty Il can be equipped with a second CAN channel Therefore a 82527 will be mounted on the PCB The C165 uses the CS3 signal to select the 82527 If 2 CAN channels are used there is no standard pinning at the D Sub connector The physical line driver for the second CAN channel is available via the connecting cable not included in standard delivery contents and can be used optional by your special application In stade of the second CAN channel a diagnosis channel can be used Therefor an UART 16CS550 can be mounted on the PCB instead of the 82527 The C165 uses the CS3 signal to select the UART The physical line driver for the ISO 9141 interfacing can be ordered separately he 1 03 L ME Hardware Physical Interface 3 4 Physical Interface NetPorty Il has the transceiver chip 82C251 according to ISO 11898 as physical interface It is not galvanic disconnect The standard physical interface is linked to the SJA1
17. o ime actia de LE Version u Introduction System Requirements 1 2 System Requirements PC requirements e standard PC with RS232 or Centronics EPP 1 7 or 1 9 interface e other device with standard RS232 interface used signals described in chapter Hardware Versin 1 03 L ME Introduction Delivery Contents 1 3 Delivery Contents 1 3 1 Standard Your NetPorty Il delivery package Order code IME 1602401 includes e 1 NetPorty Il e 1 System user manual hardware software e Transfer tools to NetPorty Il e LevelX software driver for design of 32 bit Windows applications Windows 95 and Windows NT including sample programs running on standard firmware e PCCANControl for Windows Windows 95 and Windows NT version e RS232 adapter cable set 1 3 Supplementary Support e Power supply e Different cables for protocol interfacing on request LE Version pe Introduction Technical Specifications 1 4 Technical Specifications DC DC Converter parallel Protection SAB80C 165 serial Power connector 9 pinning D Sub connector for PC interfacing 25 pinning D Sub I MAX232C 512 KB RAM 16bit 128 KB Flash 8 bit SJA 1000 LED General Characteristics of NetPorty Il Processor Protocol Interface Phys
18. r industrial and automotive analyzes and diagnostics With NetPorty Il you can visualize bus traffic and configure components within a CAN network It enables you to transfer software from or to control components The data can be exported to readable by standard PC programs like Excel In this way the user can generate statistic diagrams etc to analyze the CAN communication In the I ME standard software you can set bus specific values For transmitted or received data it is possible to assign fix display to one CAN message In addition to the above mentioned features you can transfer your own programs to NetPorty Il by the use of the RS232 link The download utilities are included as well as sample programs The NetPorty II can optionally be equipped with an UART for automotive diagnosis In this case it is a converter RS 232 or Centronics to ISO 9141 K Line Working with the parallel port is 2 5 times faster as the serial port access The speed depends on the PC speed a 1 03 L VIE Introduction Your I ME NetPorty Il I ME ACTIA is always eager to full fill the needs of our customers If problems should occur please refer to Troubleshooting If the problem persists then feel free to contact our after sales support hotline using the following number After sales service I ME ACTIA GmbH Rebenring 33 D 38106 Braunschweig Germany Tel 49 531 38 701 38 Fax 49 531 38 701 88 e mail inf
19. rdware you should connect the NetPorty Il to the serial or to the parallel port of your PC If the NetPorty Il operates at the serial port of the PC the adapter cable will be used to get the right signals Plug in the 25 pin D Sub connector of the adapter cable to the NetPorty Il and the 9 pin D Sub connector to the serial interface of the PC The NetPorty Il can operate at the parallel port which must be configured as EPP V1 7 or V1 9 mode ECP mode is not supported Make sure that the right interrupts are used in the systems configuration and the BIOS settings 1 EPP Enhanced Parallel Port ECP Extended Capabilities Port Sl 1 03 L VIE Installation Installing the Hardware It is also necessary to connect the NetPorty Il with a power supply Therefore an external power unit can be used to supply the NetPorty Il via the power connector or via the 9 Pin D Sub CAN connector Centronics a AVE E ACTIA Power supply Fa Fa If all connections are done NetPorty ll is operational and the next step is the software installation LE Version Ps Installation Installing the Software 2 3 Installing the Software 2 3 1 If you start at serial port Driver installation 1 Insert the CD The setup programm will start automatic if not please start the program START EXE in root path Go to Software Installation Choose your operating system is important Choose your hardware component at the
20. s 1 7 and 1 9 If necessary configure your PC and re start it 2 Follow steps 1 5 under chapter 2 3 1 3 Configure the right driver Change to directory MME ACTIA CANctrl PTY ParDrv95 ParDrvNT and start the batch file Drvinst bat 4 Atthis point you have to reboot your PC to start the right driver 5 Install PCCANControl follow steps 1 5 under chapter 2 3 1 Application installation Problems see also chapter troubleshootings You start PCCANControl but the connection doesn t work For parallel port usage it is necessary to have the EPP loader firmware BOOTLOAD H86 in the NetPorty Il Flash EPROM All Porty s are delivered with this loader but it is possible that you have overwritten it by your own firmware In this case it is possible to download the EPP firmware again into the NetPorty Il Flash L ME Version 102 Installation Installing the Software This software is a Win32 Console Application and runs under Win95 and WinNT Usage Connect your NetPorty Il with one serial port f you do not use COMI please change it into the file L BAT Start L BAT f you get error messages like BSL no response from the target hardware it is possible that you have used the wrong COM port If you get the message below COMx Loading bootload h86 Ready without any error message in the next line all activities are correct finished Leave the software with pressing the ESC key
21. six products groups are 1 CAN System Test amp Design Tools Support of various user ap plication phases Learning proto typing testing and evaluation of networked systems Comfortable Real Time simulation of message transfer characteristics in CAN networks Tools for mobile diagnosis and tests 2 CAN PC Interfaces Easy interfacing between PCs Laptops notebooks and networks with automotive fieldbus proto cols Available for all PC standard interfaces such as ISA slot PCI backplane RS232 Centronics and PCMCIA Development of applications under DOS Windows according to Real Time requirements is supported 3 CAN Industrial I O NiPC is an intelligent hardware concept for sensor actuator inter facing A modular architecture al lows the flexible change target micro controllers for process control 4 CAN System Application Software Enabling Real Time system modeling testing of networked systems as well as application support Offering basic services for network communication which is applicable for various processors and programming languages Facilitating the application interface for distributed industrial process control according to the CAL standard by CiA Support of Windows 3 1 Windows 95 amp NT 5 CAN System Know How Promoting the understanding of various network protocols in practice Understanding of CAN networks with CAL in practice Developing HW SW solutions for
22. tem hardware component that manages the operation of PCMCIA sockets in conjunction with system software SYSTEM INI A Windows initialization file similar to the CONFIG SYS file for DOS that contains Windows device drivers commands and settings you can use to customize Windows for your system s hardware Upper Memory Memory area within the PC address space between 640 KB and 1 MB This area is used by hardware devices like graphics controller The DPRAM of the CANcard is located in the Upper Memory LME Glossary V 1 00 5 3 For more informations 6 Literature Literature Literature 1 SAB 80C167CR User Manual Siemens AG 2 SAB C167CR Description of the On chip CAN Module Siemens AG 3 CIA DS 102 1CAN in Automation e V Le ME
23. viation for Basic Input Output System A set of instructions routines stored in ROM These routines work closely with hardware devices memory chips disk drives and monitor to input and output interrupt requests indicating when a device is ready to accept or send data CONFIG SYS A system configuration com mand file that contains install able device drivers memory management commands and control files that DOS accesses and uses when your system starts up DPRAM Dual Ported Random Access Memory The data for communication between PC and CANcard are exchange via a DPRAM VO An abbreviation for Input Output Refers to the sending input and receiving output of data through an 110 channel in the CPU Example The keyboard inputs data to the 110 channel in the CPU that in turn is output to the monitor IRQ An abbreviation for Interrupt Request A signal sent by a device and routed through the BIOS indicating when a device is ready to accept or send data PCMCIA Personal Computer Memory Card International Association a trade association of leading hardware and software vendors established to adopt a set of standards pertaining to adapter slots and PC cards for portable PC accessories Slot A receptacle on a micro portable laptop or palmtop computer that is used to insert and operate PCMCIA PC Cards Also referred to as a Socket Socket Same as Slot see above Socket Controller A PC sys
Download Pdf Manuals
Related Search
Related Contents
pour finir de vous en convaincre je vous propose un cocktail anti LogiLink AA0070 screen protector Samsung Galaxy Tab 4 (7.0, LTE) Εγχειρίδιο χρήσης SIGNALISATION FRANCAISE SNCF - signaux et 取扱説明書 - 富士工業株式会社 使用説明書 Carlo Fiorentini: Per una scuola di qualità per tutti 新年明けましておめでとうございます。 本年もどうぞ V7 Projector Lamp for selected projectors by CHRISTIE, DIGITAL PROJECTION, Copyright © All rights reserved.
Failed to retrieve file