Home
        Coleman Echelon FC8T User's Manual
         Contents
1.     5 year limited parts warranty     FEATURES    e Two stage heating operation includes     Two stage gas valve    Two stage inducer operation  e Provides increased comfort level  amp  very quiet unit oper   ation  e Adjustable delay timer allows two stage operation with  single stage thermostat  e Compact  easy to install  ideal height 40  cabinet  e Blower off delay for cooling SEER improvement   e Easy to connect power control wiring   e Built in  high level self diagnostics with fault code display   e Low unit amp requirement for easy replacement applica   tion   e Integrated control module for reliable  economical opera   tion   e High velocity filter and side  return filter rack provided for  easy field installation   e Electronic Hot Surface Ignition saves fuel cost with  increased dependability and reliability   e Induced combustion system with inshot main burners for  quiet  efficient operation   e 100  shut off main gas valve for extra safety   e PSC  four speed  direct drive motor with large  quiet  blower   e 24V  40 VA control transformer and blower relay supplied  for add on cooling   e Hi tech tubular aluminized steel primary heat exchanger   e Timed on  adjustable off blower capability for maximum  comfort   e Solid removable bottom panel allows easy application   e Easy access from front of unit for cleaning  maintenance  or service   e Insulated blower compartment for quiet operation   e Independent door removal for greater durability and ease  of access   
2.    Heating   Air Conditioning    TECHNICAL GUIDE  Echelon  MODELS  FC8T LC8T    GAS FIRED  HIGH EFFICIENCY TWO STAGE  UPFLOW HORIZONTAL FURNACES    STANDARD  amp  LoNOx    80  AFUE    NATURAL GAS  60   120 MBH INPUT       EFFICIENCY  RATING  CERTIFIED       a     atk   000 REGISTER  This product was manufactured  in a plant whose quality system  is certified registered as being   in conformity with ISO 9001        Due to continuous product improvement  specifications  are subject to change without notice     Visit us on the web at www york com for the most  up to date technical information     Additional rating information can be found at  www gamanet org     036 21603 002 Rev  A  1004     DESCRIPTION    These high efficiency  compact units employ induced com   bustion  reliable hot surface ignition and high heat transfer  tubular heat exchangers  The units are factory shipped for  installation in upflow or horizontal applications    These furnaces are designed for residential installation in a  basement  closet  alcove  attic  recreation room or garage  and are also ideal for commercial applications  All units are  factory assembled  wired and tested to assure safe depend   able and economical installation and operation    These units are Category   listed and may be common  vented with another gas appliance as allowed by the  National Fuel Gas Code     WARRANTY    20 year limited warranty on the heat exchanger    10 year heat exchanger warranty on commercial applica   tions
3.  min    Subtract the total system static from 0 50 w c   125 Pa  and divide  this difference by the difference in ESP values in the table  0 60 w c    150 Pa    0 50 w c   125 Pa   to obtain a percentage     0 58   0 50     0 60   0 50    0 8   Multiply percentage by airflow difference to obtain airflow reduction    0 8  X   90     72   Subtract airflow reduction value to airflow   0 50 w c   125 Pa  to  obtain actual airflow   0 58 inwc  144 Pa  ESP    2125   72   2053    UNIT CLEARANCES TO COMBUSTIBLES  ALL DIMENSIONS IN INCHES    ALL SURFACES IDENTIFIED WITH THE UNIT IN AN UPFLOW CONFIGURATION     TOP FRONT LEFT SIDE   RIGHT SIDE  FLUE  SERCO cd o E a Ec FLOOR    loser ancovelarrio _ INE  A nen dls  aa      UPFLOW      UPFLOW BENT A    14 1 2    cabinet models only  All other units    0    clearance   14 1 2    cabinet left airflow applications only  All other units and right hand airflow applications    0    clearance    Line contact only permitted between lines formed by the intersection of the rear panel and side panel  top in horizontal position  of the furnace jacket and building joists  studs or  framing     w N gt       6  COMBUSTIBLE  YES      ee e e o       Unitary Products Group    ACCESSORIES  PROPANE  LP  CONVERSION KIT    1NP0480   All units    This accessory conversion kit may be used to convert natural  gas  N  units for propane  LP  operation  Conversions must  be made by qualified distributor or dealer personnel     036 21603 002 Rev  A  1004     EXTERNAL 
4. 00  eno    Field Wiring for Two Stage Thermostat    o LEN       Field Wiring for Single Stage Thermostat    Unitary Products Group 5    036 21603 002 Rev  A  1004     FILTER PERFORMANCE   The airflow capacity data published in the    Blower Perfor   mance    table listed above represents blower performance  WITHOUT filters  To determine the approximate blower per   formance of the system  apply the filter drop value for the fil   ter being used or select an appropriate value from the    Filter  Performance    table shown below     FILTER PERFORMANCE   PRESSURE DROP INCHES W C     Airflow Minimum Opening Size    Range    0 750 0 07    751 1000  1007 1250  1251   1500    1501 1750 a    1751   2000 50985   at   oe 0   T  2001  amp Above  463   6e   o   on   os   o        Washable fiber are the type supplied with furnace  if supplied      APPLYING FILTER PRESSURE DROP TO  DETERMINE SYSTEM AIRFLOW    To determine the approximate airflow of the unit with a filter in place   follow the steps below     1  Select the filter type     2  Select the number of return air openings or calculate the return  opening size in square inches to determine the proper filter  pressure drop     3  Determine the External System Static Pressure  ESP  without  the filter     4  Selecta filter pressure drop from the table based upon the num   ber of return air openings or return air opening size and add to  the ESP from Step 3 to determine the total system static     5  If total system static matches a E
5. BOTTOM RETURN FILTER RACK W FILTER    Provides a cleanable  high velocity type filter and filter rack   Attaches to the bottom of the furnace     1BR0314   For 14 1 2    cabinets   1BR0317   For 17 1 2  cabinets   1BR0321   For 21  cabinets   1BR0324   For 24 1 2  cabinets   HIGH ALTITUDE PRESSURE SWITCHES      Used to convert units for operation at altitudes from 4 500 ft   to 10 000 ft     mon  MBH  5 500 Ft  0 000 Ft             Pom   Poo  E II IA  C o f e f 1Ps0302   1PS0302    wo      f Psoe   Psn      115 92 1PS0312 1PS0311    TPS0312   1PS03H    FIELD INSTALLED ACCESSORIES  ELECTRICAL    MODEL NO     DESCRIPTION    USED WITH    2ET0770010124 THERMOSTAT Two stage Heat  Cool  deluxe 24V ALL MODELS    THERMOSTAT  Two stage Heat Cool  Auto or manual changeover     21H04701024    System Switch  Heat Off Cool Auto     ALL MODELS    Fan Switch  On Auto   THERMOSTAT Two stage Heat Cool  Programmable electronic  5 1 1      2ET07700424    Auto or manual changeover     ALL MODELS    System Switch Heat Off Cool Auto  Fan Switch  Auto On     21003700124 TWINNING CONTROL ALL MODELS    Unitary Products Group       NOTES    Subject to change without notice  Printed in U S A  036 21603 002 Rev  A  1004   Copyright O by York International Corp  2004  All rights reserved  Supersedes  036 21603 001 Rev  B  0904   Unitary 5005 Norman  Products York OK    Group Drive 73069    
6. SP value in the airflow table   i e  0 20 w c   50 Pa   0 60 w c   150 Pa   etc   the system air   flow corresponds to the intersection of the ESP column and  Model Blower Speed row     6  Ifthe total system static falls between ESP values in the table   i e  0 58 w c   144 Pa   0 75 w c   187 Pa   etc    the static pres   sure may be rounded to the nearest value in the table determin   ing the airflow using Step 5 or calculate the airflow by using the  following example     Disposable    1 Opening 2 Openings 1 Opening 2 Openings  PRM   m   mw      mwe   mwe   mwe       NOTE  The filter pressure drop values in the    Filter Perfor   mance    table shown below are typical values for the type of  filter listed and should only be used as a guideline  Actual  pressure drop ratings for each filter type vary between filter  manufacturer     Filter Type      1 Opening   2 Openings   1 Opening     mw  i 01 6     EE       o      0 14     008   0 17    Example  For a 130 000 BTUH  38 06 kW  furnace with 2 return  openings and operating on high speed blower  it is found that total  system static is 0 58    w c  To determine the system airflow  complete  the following steps    Obtain the airflow values at 0 50 w c   125 Pa   amp  0 60 w c   150 Pa   ESP     Airflow   0 50     2125 CFM  60 17 m  min     Airflow   0 60     2035 CFM  57 62 m   min   Subtract the airflow   0 50 w c   125 Pa  from the airflow   0 60  w c   150 Pa  to obtain airflow difference     2035   2125    90 CFM  2 55 m
7. e LoNOx models have been designed to meet specific code  requirements   e LoNOx models may not be converted to propane     FOR DISTRIBUTION USE ONLY   NOT TO BE USED AT POINT OF RETAIL SALE    036 21603 002 Rev  A  1004     D   VENT CONNECTIONS         POWER WIRING    RIGHT SIDE  SEPIA T STAT WIRING  7 8    K O     5 8    1 3 8  26 314 pe y 1114        20          _   5 8    NO      E      7 y   4    Diam  ter lk          24 3 4     gt     BOTTOM IMAGE TOP IMAGE  RETURN END SUPPLY END       CABINET AND DUCT DIMENSIONS    Eoceen  ee   eo o eoo f e  ee  e  M   8088  1800   8  6  88  E   FLICETTOOC2OURT  3       HORIZONTAL VENTING   MUST USE FIELDS CONTROL MODELS SWG 4Y OR TJERENLAND MODEL GPAK JT FIELD  SUPPLIED POWER VENTING KITS    High   Low High   Low Furnace  BTU BTU with Feet  Feet o    5072 ae 1200 345    E ear 1200    INES eas 8   eos IES FEE IN IES II IE EI       2 Unitary Products Group    036 21603 002 Rev  A  1004     RATINGS 8 PHYSICAL   ELECTRICAL DATA    Cabinet Air Temp  Rise Max  Outlet  a P  Air ps     F L C8TO60A12UH11      F L C8TO60A12UH11      a    MENOR    UU 14  el 80 0   0 SS 55    00        FC8T120016UH11   96 64 1600 25 55 180     F L C8T120C20UH11 96 64 2000    800   0 25 55    sioner     Max Over current Min  Operation  Blower  E S E S Size  awg  O Wire WGT   75 ft protect one way LBS  ION  600 AA AN NA DE 107  OCT A ARO o AR O SES E AE A   FL C8T080B16UH11   64 48    FCETIOOBTZUAA   80 53 g    E IEA  FCSTIZOCISUHA   98 64 LES  FLoaTZ0CzOUHTT  95  m
8. o    Annual Fuel Utilization Efficiency  AFUE  numbers are determined in accordance with DOE Test procedures   Wire size and over current protection must comply with the National Electrical Code  NFPA 70 latest edition  and all local codes   The furnace shall be installed so that the electrical components are protected from water        FILTER SIZES    Cabinet Size Side  in  Bottom  in   A 18x28 14x28    16 x 26 16 x 26       PIE 20x28  es PEE 20x28      ESP  External Static Pressure   5  WG is at furnace outlet ahead of cooling coil   NOTES     1  All filters must be high velocity cleanable type   2  Air flows above 1800 CFM require either return from two sides or one side plus bottom     Unitary Products Group 3    036 21603 002 Rev  A  1004   TABLE 1  Blower Performance CFM   Upflow  without filter    Bottom Return    MODELS Two Stage Bottom Airflow Data  SCFM   Input   Speed Ext  Static Pressure  in  H20     n 01   02   03   oa   o5   06   07   08   09    ao eo o 1420 o eo o   oo   990  870   700  eT   Medium Low   1200    80   1150   100   1050   990   920   e30   700   580    tow   960   960   eso   930   800   s4   800   720   610 500  ELycatosoatouni  Medium High   1400   1360   1310   1260   1200   120   1070   960   860   740    Medium Low   180   1160   1130   1090   1040   990   920   840   750  640   FL C8TOSOB1GUH11  o  ol  FC8T120C16UH1   E  NOTES    1  Airflow expressed in standard cubic feet per minute  CFM  and in cubic meters per minute  m min    2  Motor v
9. oltage at 115 V     Input   CFM   Cabinet Width  A 14 1 2  B 17 1 2  C 21  D 24 1 2         4 Unitary Products Group    036 21603 002 Rev  A  1004   TABLE 2  Blower Performance CFM   Upflow  without filter    Left Side Return    MODELS Two Stage Left Side Airflow Data  SCFM     Input   Speed Ext  Static Pressure  in  H20   CFM 0 7    EEN     tow        900   900   900   80   850   790   730   660   530   FL C8TO80A12UH11  Medium High   1420   1970   1850   1320   1280   1280   1970   1090   980   840  Medium tow   1080   1120   110   1100   1080   1040   1000   920   820   690   tow   WA   o0   900   800   670   850   800   780   670   560  EOIN     D N  iw        oso   o   om   920   s90   e50   770   660   560  PO     FC8T120C16UH11  POPE  NOTES    1  Airflow expressed in standard cubic feet per minute  CFM  and in cubic meters per minute  m min    2  Return air is through side opposite motor  left side    3  Motor voltage at 115 V      Input   CFM   Cabinet Width  A 14 1 2  B 17 1 2  C 21  D 24 1 2               TWO STAGE  THERMOSTAT    pall LS Rwa       INTEGRATED    WHT     g WHT  NEUTRAL  120 VOLT CONTROL    BLK__ a BLK  HOT  ieee    NOMINAL          TSTAT  COMMON  CONNECTION        GRN a GRN  L                     OUTDOOR       REMOTE T STATUS  fo   SWITCH    ERROR uot    REMOTE T DUO  z G   a o  SWITCH ERROR Da    SINGLE STAGE  THERMOSTAT    i     3    5  Q   8    O  8  que    O  IVA OZI   NOLLMWI    xjo  zj  El     B    HUM    TSTAT  COMMON  CONNECTION    WOW  OOO  0
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Behringer Europack UB1202 User's Manual  Hoshizaki KM-501MRH User's Manual  施工説明書  THE ABSOLUTE TUNE MANUEL D`UTILISATION  Omron Healthcare MC-509N Thermometer User Manual    USER- MANUAL  Ramp-to-LL Install Instr (NEW)  - Sturdy-Lite  Philips CD4552B Cordless phone answer machine      Copyright © All rights reserved. 