1. CITIZEN INSTRUCTION MANUAL _for DIGITAL THERMOME R E a pa PLEASE READ THIS MANUAL IN ANY CASE BEFORE USING PARTS NAMES Display Push button Probe ONSOFF switch CITIZEN 3EB T Probe tip Fever sensor Main bod Using antibacterial material PRECAUTIONS 1 Do not use this thermometer for measurements other than body temperature The thermometer will be damaged if it is used to measure the temperature of bath refrigerators etc 2 Do not drop the thermometer and do not expose the thermometer to heavy shock As the thermometer is not shock protected construction 3 Do not bend the thermometer 4 Do not bite the probe 5 Do not disassemble the unit do not make any modifications and do not touch the cir cuitry 6 Do not spill chemical solvents on the unit T Do not store the unit in direct sunlight not at high temperature and not at a high degree of humidity or dust 8 Do mot boil the probe 9 Do not use the thermometer if it operates irregularly or shows sings of malfunction 10 Do not use thinner or benzine 11 When using the thermometer after storage at low temperature place it in a warm place for 5 to 10 minutes before use 12 Keep the thermometer out of reach of children 13 Wipe the thermometer clean before storing 14 In order to measure the temperature more appropriately hospitals recommend to re quire times in case of the mouth oral measurement for over 5 m
2. eased 2 When release the ON OFF switch i b 5 C will show on the display and then the gf with flashing C indicates thermometer being ready to take a temperature The temperature reading should take about ninety seconds 3 When the peak temperature has been reached C will stop flashing and beeper will sound for four seconds 4 To tum the unit off press the ON OFF switch If the thermometer is inadvertently left on after use it will automatically shut off in 16 minutes Remarks 1 if the ambient mpenn is Bid than 32 0 C the display will not show Oo 2 if the temperature goes fever than 32 0 C the display will only show i e but if the temperature goes higher than 42 9 C it will show 3 Temperature should only be taken under the supervision of an adult and it is not suggested to take a rectal temperature with your thermometer 5 Now carry out the measurement A Measurement in the mouth oral Put the probe tip under the rear part of the tongue and chose the mouth tightiy to insure accurate readings Normal oral temperature is 37 0 C B Underarm measurement axillary The probe tip should be placed under the armpit and hold the temperature parallel to the body and put the arm on the chest so the probe tip is well covered by the arm NOTE axillary temperature is usually 0 5 C lower than oral reading Remarks When taking your temperature please use the thermometer in the same position to m
3. easure in the same time period BATTERY When the battery is weak and show the J symbol change the battery to insure precise temperature readings BATTERY REPLACEMENT 1 Push the hook placed in the click hole Click hole J op 2 Remove the exhausted battery and insert a new battery the same way which is located back side of the ther mometer with a minus screw driver and 3 Make sure that the plus side shows when the battery is in place Replace the battery cover as the same direction before the replacement of battery Slide the battery cover off Caution Swallowing the battery may be fatal If the battery has been swallowed contact a hospi tal immediately and have it removed Do not throw the battery into a fire It may explode Do not recharge the battery do not disassemble or short circuit it CLEANING Clean the housing of the thermometer with ethyl alcohol or a neutral detergent using a cloth Don t use thinner or benzine CALIBRATION CHECK We recommend a calibration check for instruments used professionally e g at clinics according to any national statutory regulations if any OTHER INFORMATION Manufacturer Name CITIZEN SYSTEMS H K LIMITED m Address flat A B 4th floor Hung Mou Industrial Building C 4 62 Hung To Road Kwun Tong Kowloon Hong Kong So European Repesentative F kame ar elektronische Ger te Vertrieb GmbH 0086 Address Fintelmannstrabe 20 Eingang Martin Heydert St
4. inutes and in case of the underarm axillary measurement for over 10 minutes 15 When discarding the thermometer or battery please observe any local waste disposal regulations currently in force in your area Battery cover IMPORTANT DATA Measurement method Measurement range Temperature peak hold thermometer 32 C 47 9 C Accuracy 40 1 C between 35 5 C and 42 C at an ambient temperature of 18 C to 26 C Display 3 digits with decimal point M Memory mark gt C C indicator Battery symbol Rated voltage DC 1 5V Direct current Battery life Approx 3 years if used 1 time a day for 10 min each time Weight Approx 10g Include battery Operating environment Temperature 10 to 40 C Relative humidity 30 to 45 Storage transport environment Temperature J0 C to 60 C Relative humidity 95 or less Electrical shock protection Internal power unit Safety classification Type B equipment Reference European standard This products complies with EC instructions 93 42 EEC Medical Device Directive and with the following standard EN1 2470 3 AN Attention consult accompanying documents HOW TO OPERATE 1 Press the ON OFF switch to activate the thermometer and po oc will show on the LCD display window to insure all parts of the display are functioning properiy By holding down the ON OFF switch the display will show the last temperature Memory 36 gf K until the switch is rel
5. raBe D 14109 Berlin Germany WEEE lf you want to dispose this product do not mix with general household waste There is a separate collection systems for used electronics products in A accordance with legislation under the WEEE Directive Directive 2002 96 EC and is effective only within European Union CITIZEN is a regstered trademark of Citizen Hokings Co Japan CITIZEN es une mema reqstrada de Citiren Hokings Co Japon Desig and spectication are subject to change wethout notice CITIZEN SYSTEMS JAPAN CO LTD 61 12 Tanashecho Nish TokyoeGhi Tokyo 168 8511 Japan E mail sales oe systems ctizencojp https waw cititen systems cojp
Download Pdf Manuals
Related Search
Related Contents
descargar el manual del usuario IB for MS2651DVB Peerless ACC640-B flat panel ceiling mount FOCUS Enhancements MR-HD100 User's Manual Sony NWZ-S716F User's Manual Brennenstuhl BN-HASP01 VICTOR JT-V45 Users Manual (Japanese) 9 - GT Innovations Quiet Glide HPIDHP2000 Instructions / Assembly Copyright © All rights reserved.