1. H6420 SPA Installation and Removal A Warning During this procedure wear grounding wrist straps to avoid ESD damage to the card Do not directly touch the backplane with your hand or any metal tool or you could shock yourself Statement 94 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 a 923 Chapter9 Removal and Replacement Procedures HI Removing and Replacing Shared Port Adapters SPAs can be inserted or removed independently from the SIP Removal of a SIP with installed SPAs is also supported Figure 9 17 illustrates how to install and remove a SPA in the SCE8000 SIP Figure 9 17 SPA Installation and Removal an J 3 270988 This number Indicates this component 1 SCE8000 SIP 2 1X10GBE SPA module Installing a SPA in a SIP To install a SPA in a SIP refer to Figure 9 17 and do the following Step 1 At the SCE prompt type reload shutdown and press Enter to power down the Cisco SCE8000 platform before installing or removing any module Step2 To insert the SPA in the SIP locate the guide rails inside the SIP that hold the SPA in place They are at the top left and top right of the SPA slot and are recessed about an inch as shown in Figure 9 17 Step3 Carefully slide the SPA all the way in the SIP until the SPA is firmly seated in the SPA interface connector When fully seated the SPA might be slightly behind the SIP faceplate Ste
2. BE Cordset rating 16A 250V HL AAAN Length 14 ft 0 in 4 26 m Connector IEC 60320 1 C19 126792 E Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter4 Installing the Cisco SCE8000 Chassis Preparing for Installation W Figure 4 3 CAB AC 2500W EU a EL Cordset rating 16 A 250 V Plug CEE 7 7 Length 14 ft 0 in 4 26 m Connector IEC 60320 C19 113360 Figure 4 4 CAB AC 2500W INT SL qe Cordset rating 16 A 250 V Length 14 ft 0 in 4 26 m Plug IEC 309 Connector IEC 60320 C19 Figure 4 5 CAB AC 2500W ISRL V ls Cordset rating 16 A 250 V Length 14 ft 0 in 4 26 m 113361 Plug S116S3 Connector IEC 60320 C19 E 130113 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 EN Chapter 4 Installing the Cisco SCE8000 Chassis Preparing for Installation Figure 4 6 CAB AC 2500W US1 Plug NEMA 6 20 Figure 4 7 CAB AC
3. W Removing and Replacing the Power Supply Step2 Remove the four screws securing the terminal block cover and slide the cover off the terminal block Figure 9 3 DC Input Front Panel for 2700 W DC Input Power Supply Captive installation screws 132218 Captive installation screws Step3 Remove the two screws securing each of the cable holder covers and remove the cable holder covers off the cable holders Step4 Disconnect the DC input wires from the terminal block Always disconnect the DC input wires in this order e Positive e Negative e Ground A Warning When installing the unit the ground connection must always be made first and disconnected last Step5 Remove the two tie wraps from the ground cable If there is a long cable tie securing the cable holders remove that as well Step6 Loosen the captive installation screws on the power supply A Caution Use both hands to install and remove power supplies Each PWR 2700 DC DC 4 input power supply weighs 19 8 pounds 9 0 kg Step7 Grasp both power supply handles as shown in Figure 9 4 and slide the power supply completely out of the chassis Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 lt OL 16478 02 Chapter9 Removal and Replacement Procedures Removing and Replacing the Power Supply W Figure 9 4 Handling a DC Input Power Supply 126567 Installing a DC Input Powe
4. e Cutoff There is no forwarding of traffic and the physical link is forced down cutoff functionality at layer 1 The SPA Interface Processor card cannot preserve the link in the following circumstances e During platform reboot SW reload there is a 5 second period at most during which the link is forced down cutoff functionality e During a power failure The Cisco SCE8000 has two power supplies A power failure occurs only when both of them fail e Under certain types of failure within the SIP module the SPA cards or the XFP optic modules External Optical Bypass In installations in which the limitations of the internal bypass are not acceptable an external optical bypass device can be used to provide dependable link continuity The external optical bypass device can be installed either inside the Cisco SCE8000 chassis or be rack mounted externally The external optical bypass device can also be controlled manually by specific CLI commands Under normal operating conditions traffic flows through the link as usual with the exception that the optical bypass module sits on the link OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter3 Cisco SCE8000 Topology and Topology Related Parameters HZ Link Continuity Figure 3 9 Optical Bypass Under Normal Operating Conditions Subscriber 1 m d OPB Network 1 gt 3 0
5. 0xb803 cpld 1 ufm 0xb803 cpld 2 ufm 0xb803 summit 0 0x1000a summit 1 0x1000a fc 0x1044 Slot 3 SIP 8000 serial num CAT1204G01H part num 73 10947 01 cpld 0x9162 summit 0 0x10006 summit 1 0x10006 dpt 0 0x3033 dpt 1 0x3033 spa 0 SPA 1X10GE L V2 spa 1 SPA 1XTENGE XFP spa 2 SPA 1X10GE L V2 spa 3 SPA 1XTENGE XFP product num CISCO7604 serial num FOX10420BKZ part num 73 9789 02 part rev AO vid V01 Part number 73 10598 01 38 Revision Software revision LineCard S N CAT1202G07D Power Supply type AC SML Application information is No application is configured Logger status Enabled Platform SCE8000 4x10GBE Management agent interface version Software package file SCE8000 uptime is 9 minutes SCE Agent 3 1 6 Build 134 ftp ftpserver simba pkg 54 seconds Removing and Replacing Modules OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 Hl Chapter9 Removal and Replacement Procedures HI Removing and Replacing Shared Port Adapters After you verify installation of an SCE8000 module and check connectivity you must configure the module For complete information on configuring the Cisco SCE8000 platform refer to the Cisco SCE8000 Software Configuration Guide For information on all Cisco SCE8000 platform commands refer to the Cisco SCE8000 CLI Command Reference publication Removing and Replacing Shared Port Adapters When removi
6. Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter7 Basic Cisco SCE8000 Platform Operations How to Display the SCE Platform Version Information Ml RDR formatter forwarding mode multicast RDR formatter destination 10 56 96 26 port 33000 category number 1 priority 100 RDR formatter destination 10 56 96 26 port 33000 category number 2 priority 100 RDR formatter destination 10 56 96 26 port 33000 category number 3 priority 100 RDR formatter destination 10 56 96 26 port 33000 category number 4 priority 100 interface LineCard 0 connection mode inline on failure external bypass no silent no shutdown attack filter subscriber notification ports 80 replace spare memory code bytes 3145728 interface GigabitEthernet 1 1 ip address 10 56 96 46 255 255 252 0 interface TenGigabitEthernet 3 0 0 bandwidth 10000000 burst size 50000 global controller 0 name Default Global Controller interface TenGigabitEthernet 3 1 0 bandwidth 10000000 burst size 50000 global controller 0 name Default Global Controller interface TenGigabitEthernet 3 2 0 bandwidth 10000000 burst size 50000 global controller 0 name Default Global Controller interface TenGigabitEthernet 3 3 0 bandwidth 10000000 burst size 50000 global controller 0 name Default Global Controller exit ip default gateway 10 56 96 1 line vty 0 4 exit management agent property com pcube management framewor
7. The Logging System 8 11 How to Copy the User Log to an External Source 8 12 How to Copy the User Log to an Internal Location 8 12 How to View the User Log 8 12 How to Clear the User Log 8 12 How to View the User Log Counters 8 13 How to View the Non volatile Counter For the User file log Only 8 13 Generating a File for Technical Support 8 13 Removal and Replacement Procedures 39 1 Safety 9 1 Preventing Electrostatic Discharge Damage 9 2 Supported Removing Requi Remo Insta Remo Insta Removing Requi Remo Insta Removing Requ Hardware 9 3 and Replacing the Power Supply 9 3 red Tools 9 3 ving an AC Input Power Supply 9 3 ling an AC Input Power Supply 9 5 ving a DC Input Power Supply 9 5 ling a DC Input Power Supply 9 7 and Replacing the Fan Assembly 9 10 red Tools 9 10 ving the Fan Assembly 9 11 ling the Fan Assembly 9 11 and Replacing Modules 9 12 ired Tools 9 12 Hand ing SIPs 9 13 OL 16478 02 Contents W Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E E Contents Installing a Module 9 13 Removing a Module 9 17 Inserting and Removing a Module Detail 9 19 Verifying the Installation 9 20 Removing and Replacing Shared Port Adapters 9 22 Required Tools and Equipment 9 22 Laser LED Safety 9 22 Handling SPAs 9 23 SPA Installation and Removal 9 23 Installing a SPA ina SIP 9 24 Removing a SPA froma SIP 9 24 Removing and Replacing the Optical Bypass Module 9 25 Rem
8. The external optical bypass device is used to bypass traffic maintaining link continuity at all times Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 Ea OL 16478 02 Chapter3 Cisco SCE8000 Topology and Topology Related Parameters Asymmetric Routing Topology W In a single Cisco SCE8000 topology the value of this parameter is determined by whether or not the link can be completely cut when the Cisco SCE8000 fails or whether traffic flow should continue across the link in spite of platform failure In the latter case the External bypass mode is the recommended setting and is therefore the default value for the on failure mode parameter In a dual cascaded Cisco SCE8000 topology the default on failure mode is Bypass since it preserves full traffic processing functionality on both links in most single box failures as long as the SPA interface card is functioning properly e Cutoff mode is suggested for the following Non redundant inline topology if value added services such as security are crucial and are more important than maintaining connectivity e Bypass mode is suggested for the following Non redundant inline topology if connectivity is of high importance n redundant inline setups if cutoff or traffic loss on a single link for a period of up to ten minutes during a rare event of a SPA interface card failure can be tolerated e External bypass mode is suggested for the following
9. e Chassis mount The optical bypass module may be installed in the panel in slot 4 of the Cisco SCE8000 chassis This panel hosts up to two optical bypass modules e External mounting panel The optical bypass module may be installed in a panel that is mounted in a 19 rack This panel can host up to four optical bypass modules amp Note Make sure to use the correct type of optical bypass module single mode or multi mode according to the transceivers and cabling that are used for the subscriber and network links Note Since the optic bypass module will directly connect the subscriber and network side optic paths when bypassing the SCE8000 the subscriber and network optic links must be of the same type single mode or multi mode and wavelength A Warning Invisible laser radiation may be emitted from disconnected fibers or connectors Avoid exposure to radiation and do not stare into open aperture Optical Bypass Module Connectivity e Single Link Topology page 6 9 e Dual Link Topology page 6 9 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 lt OL 16478 02 Chapter6 Cabling the Line Ports and Completing the Installation Cabling the 10GBE Line Interface Ports W Single Link Topology A single link requires only one bypass module Subscriber side network element lt gt Port A on the bypass module Cisco SCE8000 port 3 0 0 lt gt Port C on the bypass module Network sid
10. Removal and Replacement Procedures This chapter describes how to perform removal and replacement procedures for Cisco SCE8000 platform field replaceable units FRUs Warning Safety A Before you install operate or service the system read the Regulatory Compliance and Safety Information for the Cisco SCE8000 This guide contains important safety information you should know before working with the system e Safety page 9 1 e Preventing Electrostatic Discharge Damage page 9 2 e Supported Hardware page 9 3 e Removing and Replacing the Power Supply page 9 3 e Removing and Replacing the Fan Assembly page 9 10 e Removing and Replacing Modules page 9 12 e Removing and Replacing Shared Port Adapters page 9 22 e Removing and Replacing the Optical Bypass Module page 9 25 Warning A Before working on a chassis or working near power supplies unplug the power cord on AC units disconnect the power at the circuit breaker on DC units Warning A The plug socket combination must be accessible at all times because it serves as the main disconnecting device Warning Class 1 laser product OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter9 Removal and Replacement Procedures HZ Preventing Electrostatic Discharge Damage A Warning Because invisible laser radiation may be emitted from the aperture of the port when no cable is connected avoid e
11. connect to Port 3 2 0 in Cisco SCE8000 1 Inline topologies require connecting both Receive and Transmit fibers to the Cisco SCE8000 Cascade ports always require both Receive and Transmit fibers to be connected To maintain link continuity at all times two optical bypass modules should be installed and the traffic ports should be connected to these bypass modules OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter6 Cabling the Line Ports and Completing the Installation HZ Connecting the Line Ports to the Network Multi Gigabit Service Control Platforms MGSCP Topologies In this topology multiple Cisco SCE 8000 platforms are connected to a Cisco 7600 Series router used as a load balancer dispatcher between the platforms Traffic enters the router is distributed between the Cisco SCE8000 platforms by the router EtherChannel and returns to the router to be forwarded to its original destination General guidelines for MGSCP topologies Since there are two links per Cisco SCE8000 platform the minimum number of platforms required is half the number of links used Each link corresponds to one port on the EtherChannel EC on the Cisco 7600 Series router Each EC supports a maximum of eight active ports Therefore if all eight EC ports are configured four Cisco SCE8000 platforms are required For N 1 redundancy two additional ports connected to the standby platform must be conf
12. cpld 2 Oxb20e cpld 0O ufm 0xb803 cpld 1 ufm 0xb803 cpld 2 ufm 0xb803 summit 0 0x1000a summit 1 0x1000a fc 0x1044 Slot 3 SIP 8000 serial num CAT1204G01H part num 73 10947 01 cpld 0x9162 summit 0 0x10006 summit 1 0x10006 dpt 0 0x3033 dpt 1 0x3033 spa 0 SPA 1X10GE L V2 spa 1 SPA 1XTENGE XFP spa 2 SPA 1X10GE L V2 spa 3 SPA 1XTENGE XFP product num CISCO7604 serial num FOX10420BKZ part num 73 9789 02 part rev A0 vid VOL Part number 73 10598 01 38 Revision Software revision LineCard S N CAT1202G07D Power Supply type AC SML Application information is No application is configured Logger status Enabled Platform SCE8000 4x10GBE Management agent interface version SCE Agent 3 1 6 Build 134 Software package file ftp ftpserver simba pkg SCE8000 uptime is 9 minutes 54 seconds OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 zl Chapter7 Basic Cisco SCE8000 Platform Operations W How to Display the SCE Platform Inventory How to Display the SCE Platform Inventory Unique Device Identification UDI is a Cisco baseline feature that is supported by all Cisco platforms This feature allows network administrators to remotely manage the assets in their network by tracing specific devices through either CLI or SNMP The user can display inventory information for a remote device via either e Entity MIB se
13. installed in slot 4 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 e445 Chapter 4 Installing the Cisco SCE8000 Chassis HZ Connecting the System Ground Step2 Remove the module filler plate covering the subslot in the mounting panel by loosening the two screws Step3 Carefully insert the optical bypass module into the subslot there are no guide rails and tighten the captive screws on either side of the module Figure 4 15 Optical Bypass Modules in External Mounting Panel 270994 OP OO 8 O10 1B 0000000 So 28 ooooooo o Q e Connecting the System Ground This section describes how to connect a system earth ground to the Cisco SCE8000 chassis Note You must connect the system ground on both AC and DC powered systems to an earth ground if this equipment is installed in a US or European Central Office Note For DC powered systems the system ground is also the power supply ground The DC ground must be installed with a permanent connection to an earth ground according to NEC guidelines Two threaded M4 holes are provided on the chassis frame to attach the ground cable Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 aie E OL 16478 02 Chapter4 Installing the Cisco SCE8000 Chassis Connecting the System Ground W You must complete this procedure before connecting system po
14. of a subscriber e Pull Mode The SM sends subscriber information to the SCE platform in response to a query from the SCE platform Service Configuration Management Service configuration management is the ability to configure the general service definitions of a service control application A service configuration file containing settings for traffic classification accounting and reporting and control is created and applied to an SCE platform The SCA BB application provides tools to automate the distribution of these configuration files to SCE platforms This standards based approach makes it easy to manage multiple devices in a large network Service Control provides a GUI to edit and create these files and a complete set of APIs to automate their creation Data Collection Data collection occurs as follows 1 All analysis and data processing functions of the SCE platform result in the generation of Raw Data Records RDRs which the SCE platform forwards using a simple TCP based protocol RDR Protocol 2 RDRs are processed by the Cisco service control management suite collection manager 3 The collection manager software is an implementation of a collection system that receives RDRs from one or more SCE platforms It collects these records and processes them in one of its adapters Each adapter performs a specific action on the RDR RDRs contain a variety of information and statistics depending on the configuration of the sy
15. 0 3 1 0 3 2 0 3 3 0 BD Network 2 OPB Subscriber 2 270904 If the SCE8000 platform fails traffic flows through the optical bypass module bypassing the SCE8000 so that traffic on the link is maintained Figure 3 10 Optical Bypass Under Failure Conditions Subscriber 1 ay etwor Zz Coors 3 1 0 POIN E Aan a Se Network 2 OPB Subscriber 2 270903 Note In cascade configuration installation of the optical bypass module is required This optical bypass module can be added to link without altering the basic characteristics of the topology The installation procedure and the actual connections are somewhat different when the optical bypass module is used see Optical Bypass Module Connectivity page 6 8 For more information regarding the external bypass module refer to The Cisco SCE8000 Optical Bypass page 2 8 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 EuN OL 16478 02 Chapter3 Cisco SCE8000 Topology and Topology Related Parameters Topology Related Parameters W Topology Related Parameters Refer to the following sections to determine the correct values for all topology related parameters before beginning to run the initial setup of the Cisco SCE8000 e Connection Mode Parameter page 3 11 e Physically Connected Links Parameter page 3 12 e Priority page 3 12 e On Failure Mode Parameter page 3 12 There are f
16. 2700 AC 4 PWR Ac Fin 1 Fi 240VTSA oone Captive installation screws 126565 Captive installation screws Figure 2 11 PWR 2700 DC 4 ALL Fag TE PRONTO OnE MUST BE Fu NG THE Powe ENGAGI OWER SoASED SUPPLY Captive installation screws 132218 Captive installation screws The AC input and DC input power supplies support redundancy When power is removed from one supply the redundant power feature causes the second supply to produce full power Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 P22 E OL 16478 02 Chapter2 Introduction to the Cisco SCE8000 Platform Checking the Shipping Container Contents W Power Supply Cooling Power supplies have built in fans and are completely self cooling Air enters from the right of the fan and exits through the left Load Sharing With two power supplies each power supply concurrently provides approximately half of the required power to the system If one power supply fails the second power supply immediately assumes full power to maintain uninterrupted system operation The second power supply enables load sharing and fault tolerance automatically no software configuration is required Checking the Shipping Container Contents Use the Cisco SCE8000 Component List to check the contents of the Cisco SCE8000 platform shipping container P Tip Do not discard the shipping container when you unpack the Cisc
17. C6K TWLK Plug NEMA L6 20 Figure 4 8 CAB 7513AC roa C Cordset rating 16 A 250 V Length 14 ft 0 in 4 26 m Connector IEC 60320 C19 113362 5 i Cordset rating 16 A 250 V Length 14 ft 0 in 4 26 m Connector IEC 60320 C19 113363 Plug NEMA 5 20 L i i E Cordset rating 20 A 125 V Length 14 ft 0 in 4 26 m Connector IEC 60320 C19 113356 E Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter4 Installing the Cisco SCE8000 Chassis Preparing for Installation W Figure 4 9 CAB 7513ACSA paa Cordset rating 16 A 250 V Plug IEC 884 Length 14 ft 0 in 4 26 m Connector IEC 60320 C19 113357 Figure 4 10 CAB ACS 16 7 Cordset rating 16 A 250 V Plug SEV 5934 2 Length 8 ft 2 in 2 5 m Type 23 Connector IEC 60320 C19 113364 Figure 4 11 CAB AC 16A AUS j a Cordset rating 16 A 250 V Plug AU20S3 Length 14 ft 0 in 4 26 m Connector IEC 60320 C19 140586 Cisc
18. DESCR Container SCE8000 Service Control Module SCM slot PID VID SN NAME SCE8000 Physical Slot 2 DESCR Container SCE8000 Service Control Module SCM slot PID VID SN NAME SCE8000 Physical Slot 3 DESCR Container SCE8000 SPA Interface Processor SIP slot PIDs Ma r VIDI P ON NAME SCE8000 Physical Slot 4 DESCR Container SCE8000 Optical Bypass slot PID VID SN NAME SCE8000 Fan Module DESCR Container SCE8000 Fan Module PID VID gN NAME SCE8000 AC and DC power supply DESCR Container SCE8000 AC and DC power supply PID VID SN NAME SCE8000 Link DESCR Container SCE8000 Link PID VID SN NAME SCE8000 Backplane DESCR Container SCE8000 Backplane PID VID gN NAME SCE8000 Service Control Module SCM in slot 1 DESCR SCE8000 SCM E PID SCE8000 SCM E VID V01 SN CAT1122584N Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 a 7413 Chapter 7 Basic Cisco SCE8000 Platform Operations W How to Display the SCE Platform Inventory NAME PID PID PID PID PID PID PID PID PID PID PID PID PID PID NAME PID PID PID PID PID PID PID NAME NAME NAME NAME NAME NAME NAME NAME NAME NAME NAME NAME NAM
19. Location fora SPA 2 5 Shared Port Adapters 2 5 Modular Optics 2 6 XFP Connections 2 6 The SCE8000 SIP 2 7 The 1 Port 10GBE SPA Interface Module 2 7 The Cisco SCE8000 Optical Bypass 2 8 Optical Bypass Functionality 2 9 Optical Bypass Module Connectivity 2 9 Optical Bypass Module OPB SCE8K 2 9 Optical Bypass Module Specifications 2 11 Fan Assembly 2 11 Power Supplies 2 12 Power Supply Cooling 2 13 Load Sharing 2 13 Checking the Shipping Container Contents 2 13 CONTENTS Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 E Contents Cisco SCE8000 Component List 2 14 Cisco SCE8000 Installation Checklist 2 15 CHAPTER 3 Cisco SCE8000 Topology and Topology Related Parameters 3 1 The Cisco SCE8000 Platform 3 1 Topology Considerations 3 1 Physical Topologies 3 3 SCE8000 Interface Numbering 3 3 Single Cisco SCE8000 Topologies 3 3 Single Link Inline Topology 3 4 Dual link Inline Installation 3 4 Single Link Receive only Topology 3 5 Dual Link Receive Only Topology 3 5 Dual Cisco SCE8000 Topology Cascade 3 6 Multi Gigabit Service Control Platform MGSCP Topology 3 7 Type of SCE Platform Redundancy 3 8 Redundant Cisco 7600 Series Router 3 8 Link Continuity 3 9 Internal Bypass Mechanism 3 9 External Optical Bypass 3 9 Topology Related Parameters 3 11 Connection Mode Parameter 3 11 Physically Connected Links Parameter 3 12 Priority 3 12 On Failure Mode Parameter 3 12 Asymmetric Routin
20. Non redundant inline topology if connectivity is crucial Redundant inline setups if connectivity is crucial Note that when this mode is used the link connected to the failed box is not serviced and the other link operates with asymmetric routing functionality Asymmetric Routing Topology In some Service Control deployments asymmetrical routing occurs between potential service control insertion points Asymmetrical routing can cause a situation in which the two directions of a bi directional flow pass through different SCE platforms resulting in each SCE platform seeing only one direction of the flow either the inbound traffic or the outbound traffic This problem is typically solved by connecting the two SCE platforms in cascade mode or through an MGSCP cluster thereby making sure that both directions of a flow run through the same SCE platform However this is sometimes not feasible due to the fact that the SCE platforms sharing the split flow are geographically remote especially common upon peering insertion In this type of scenario the asymmetric routing solution enables the SCE platform to handle such traffic allowing SCA BB to classify traffic based on a single direction and to apply basic reporting and global control features to uni directional traffic Asymmetric Routing and Other Service Control Capabilities Asymmetric routing can be combined with most other Service Control capabilities however there are some exce
21. See Figure 2 4 Figure 2 4 Single Height SPA Size Front of the SCE8000 SIP Single height SPA Single height SPA Single height SPA Single height SPA 242234 e Each SPA provides a one 1OGBE port which is the interface to either subscriber or network traffic These interfaces can be individually configured using the Cisco command line interface CLI e Either a blank filler plate or a functional SPA should reside in every subslot of an SIP during normal operation to maintain cooling integrity Blank filler plates are available in single height form only Since the interfaces are connected in subscriber network pairs the SCE8000 SIP must be either fully populated or have both the bottom bays covered with blank filler plates Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 PEN Chapter2 Introduction to the Cisco SCE8000 Platform HZ Introduction to SIPs and SPAs Modular Optics amp The SPAs implement 10GBE small form factor pluggable XFP optical transceivers to provide network connectivity An XFP module is a transceiver device that mounts into the front panel to provide network connectivity Note It is highly recommended only to use the XFP modules listed as supported in this document Use of unsupported or unqualified XFP modules may affect reliability or operation Figure 2 5 10GBE Small Form factor Pluggable XFP The interface connect
22. The two Cisco SCE8000s are cascaded so the primary Cisco SCE8000 processes the traffic of the two links while the secondary Cisco SCE8000 only bypasses the traffic of its links to the primary Cisco SCE8000 for processing and then bypasses the processed traffic back to the link The two Cisco SCE8000s also exchange keep alive messages and subscriber state information In case the primary Cisco SCE8000 fails the two Cisco SCE8000s switch their roles and this way fail over is provided Figure 3 6 Two Cascaded Cisco SCE8000 Platforms Subscriber 270590 This fail over solution preserves the Cisco SCE8000 functionality and the network link Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 EN OL 16478 02 _ Chapter 3 Cisco SCE8000 Topology and Topology Related Parameters Physical Topologies W The two Cisco SCE8000s are simultaneously aware of the subscriber contexts and subscriber states are constantly exchanged between them such that if the primary Cisco SCE8000 fails the secondary can take over with minimum state loss When one Cisco SCE8000 fails depending on the type of failure its link traffic is still bypassed to the functioning Cisco SCE8000 and processed there so the traffic processing continues for both the links The bypass of the traffic through the failed Cisco SCE8000 is configurable and the user may choose to always cutoff the line that goes through the failed Cisco SCE8000 In this case
23. be accessed only through the use of a special tool lock and key or other means of security Warning There is the danger of explosion if the battery is replaced incorrectly The battery is not a user serviceable part Warning Class 1 laser product Warning Because invisible laser radiation may be emitted from the aperture of the port when no cable is connected avoid exposure to laser radiation and do not stare into open apertures Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 sai Chapter 4 Installing the Cisco SCE8000 Chassis HI Preparing for Installation A Warning Blank faceplates and cover panels serve three important functions they prevent exposure to hazardous voltages and currents inside the chassis they contain electromagnetic interference EMI that might disrupt other equipment and they direct the flow of cooling air through the chassis Do not operate the system unless all cards faceplates front covers and rear covers are in place e Preparing for Installation page 4 2 e Installing the Cisco SCE8000 Chassis in the Rack page 4 12 e Connecting the System Ground page 4 16 e Installing the Power Supplies in the Cisco SCE8000 Chassis page 4 18 Preparing for Installation e Safety page 4 2 e Site Requirements page 4 2 e Power Connection Guidelines page 4 4 Safety A Warning This equipment must be grounded Never defeat the ground conduct
24. circuit connected to the power supply you are installing Grasp both power supply handles as shown in Figure 9 4 Slide the power supply into the power supply bay Make sure that the power supply is fully seated in the bay Tighten the power supply captive installation screws Warning amp Power supply captive installation screws must be tight to ensure protective grounding continuity Note As the power requirement of the SCE8000 will not exceed 1350W it is not necessary to connect two pairs of input wires to each power supply Should it be desired to connect two pairs of input wires both pairs of input wires for one 2700W DC input power supply must come from the same battery system A feed and both pairs of input wires for the other power supply must come from another battery system B feed Note Step 5 For multiple DC input power supply each DC input must be protected by dedicated circuit breaker or fuse The circuit breaker or fuse should be sized according to the power supply input rating and local or national electrical code requirements Remove the four screws securing the terminal block cover and slide the cover off of the terminal block DC Input Front Panel for 2700 W DC Input Power Supply Figure 9 5 UU UTUPURURURUAL RUT etenn ron in N H 0 i nM U 132219 U ii 1 Captive installation 7 Cable holder cover screw 2 DC power cable 8 Cable
25. core e OPB SCE8K SM SMF 28 Maximum optical path fiber length of two ports is 600m Switching Time Switching time is measured from trigger to stable 90 optical output e Typical switching time 3 ms e Maximal switching time 10ms Fan Assembly The system fan assembly located in the chassis provides cooling air for the installed modules Sensors on the fan assembly and within the system monitor the internal air temperatures If the air temperature exceeds a preset threshold the environmental monitor displays warning messages Figure 2 9 Fan Assembly afneafo so USCO SCEg 200 ScEso0 J 270893 Captive installation screws If an individual fan within the assembly fails the FAN STATUS LED turns red To replace a fan assembly see Removing and Replacing the Fan Assembly page 9 10 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 nE Chapter2 Introduction to the Cisco SCE8000 Platform E The Cisco SCE8000 Optical Bypass Power Supplies The Cisco SCE8000 platform supports redundant AC or DC input power supplies The following power supplies are available for the Cisco SCE8000 platform e 2700 W DC input PWR 2700 DC 4 uses an external terminal block on the back side of the chassis for input power connection e 2700 W AC input PWR 2700 AC 4 uses an external power cord directly connected to the AC power supply Figure 2 10 PWR
26. master STEM POWER E OPTICAL TER aux PORT2 SCE8000 EXTENDED SERVICE CONTROL MODULE MASTER O SYSTEM POWER O Captive installation Ejector lever screws E Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter9 Removal and Replacement Procedures Removing and Replacing Modules W Step7 Position the module in the slot See Figure 9 11 Make sure that you align the sides of the module carrier with the slot guides on each side of the slot Figure 9 11 Positioning the Module in the Slot Insert module between slot guides EMI gasket 270907 Ejector lever fully extended Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 g ois Chapter9 Removal and Replacement Procedures HZ Removing and Replacing Modules Step8 Carefully slide the module into the slot until the EMI gasket along the top edge of the module makes contact with the module in the slot above it and both ejector levers have closed to approximately 45 degrees with respect to the module faceplate See Figure 9 12 Figure 9 12 Clearing the EMI Gasket Press down olg Press down 270908 imm Gap between the module EMI gasket and the module above it Step9 Using the thumb and forefinger of each hand grasp the two ejector levers and press down to create a small 0 040 inch 1
27. mm gap between the module EMI gasket and the module above it See Figure 9 12 Note Do not press down too forcefully on the ejector levers They will bend and be damaged Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter9 Removal and Replacement Procedures Removing and Replacing Modules Hi Step 10 While pressing down simultaneously close the left and right ejector levers to fully seat the module in the backplane connector The ejector levers are fully closed when they are flush with the module faceplate See Figure 9 13 Note Failure to fully seat the module in the backplane connector can result in incorrect operation and or error messages Figure 9 13 Ejector Lever Closure O STarus Fay 270909 Ejector levers flush with module faceplate Step11 Tighten the two captive installation screws on the module amp Note Make sure the ejector levers are fully closed before tightening the captive installation screws Removing a Module Before you remove an SCE8000 SCM you should first save the current configuration if the current configuration should be preserved and duplicated on the new SCE8000 SCM E Use the copy running config startup config command This step saves time when bringing the module back online if the configuration will remain the same or similar You can recover the configuration b
28. must be installed in slot 2 e The SCE8000 SIP module must be installed in slot 3 Step2 At the SCE prompt type reload shutdown and press Enter to power down the Cisco SCE8000 platform before installing or removing any module Step3 Make sure that there is enough clearance to accommodate any interface equipment that you will connect directly to the module ports Step4 Verify that the captive installation screws are tightened on all modules already installed in the chassis to ensure that the EMI gaskets on all modules are fully compressed in order to maximize the opening space for the new or replacement module Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 a 913 HZ Removing and Replacing Modules Chapter 9 amp Removal and Replacement Procedures Note Step 5 Step 6 If the captive installation screws are loose the EMI gaskets on the installed modules will push adjacent modules toward the open slot reducing the opening size and making it difficult to install the replacement module Remove the module filler plate by removing the two Phillips pan head screws from the filler plate To remove a module follow the procedure in Removing a Module page 9 17 Fully open both ejector levers on the new module See Figure 9 10 Figure 9 10 Ejector Levers and Captive Installation Screws scenoon some LW Ld ome fF I IT 1 Brat consou
29. real time packet flow through the Cisco SCE8000 Remember in bump in the wire topology both the Rx and Tx counters apply as traffic monitors For receive only topologies using an external splitter only the Rx counters apply The following example shows the counters of the first Ten Gigabit Ethernet interface Cisco SCE8000 show interface TenGigabitEthernet 3 0 0 counters In total octets 100 In good unicast packets 90 In good multicast packets 0 In good broadcast packets 10 In packets discarded 0 In packets with CRC Alignment error 0 In undersized packets 0 In oversized packets 0 Out total octets 93 2 324 1022342538 Out unicast packets 858086051 Out non unicast packets 0 Out packets discarded 0 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 7a E OL 16478 02 Chapter 7 Basic Cisco SCE8000 Platform Operations Managing Cisco SCE8000 Configurations W Managing Cisco SCE8000 Configurations After you have installed your SCE8000 platform hardware checked all external connections turned on the system power and allowed the system to boot up you are ready to install the Service Control application However before you install the application you might need to configure the SCE platform Instructions for configuring the SCE8000 platform are beyond the scope of this publication For further information on system and interface configuration refer to the following documents e Cisco SCE80
30. the chassis side and align the screw holes Secure the bracket to the chassis with the screws removed in Step 1 Repeat Steps 2 and 3 for the other bracket Chassis in the Rack Caution Step 1 Step 2 Step 3 To prevent personal injury or damage to the chassis never attempt to lift or tilt the chassis using the handles on modules such as power supplies fans or cards these types of handles are not designed to support the weight of the unit Lift the unit only by grasping the chassis underneath its lower edge To install the Cisco SCE8000 chassis in the equipment rack perform these steps Position the chassis in the rack as follows e Ifthe front of the chassis front panel is at the front of the rack insert the rear of the chassis between the mounting posts e Ifthe rear of the chassis is at the front of the rack insert the front of the chassis between the mounting posts Align the mounting holes in the bracket and optional cable guide with the mounting holes in the equipment rack Use a tape measure and level to choose and mark the position that the chassis is to be installed in the rack Make a mark at equal height on both sides of the rack This will help ensure that the chassis will be installed straight and level Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 Pai D OL 16478 02 Chapter4 Installing the Cisco SCE8000 Chassis Installing the Cisco SCE8000 Chassis inthe
31. the power subsystem In the normally configured Cisco SCE8000 platform with redundant power supply units it is unlikely that the device will not start at all However at startup it should be verified that both power supply units are operational and therefore the following steps should be followed if the Power LED on the front panel remains unlit when the Cisco SCE8000 platform is powered up Note If the system powers off due to an environmental shutdown wait at least one minute before manually rebooting the system or it will pause indefinitely Table 8 5 Troubleshooting the Power Subsystem Symptom Possible Cause Possible Solution Power LED on the front Power cable not fully seated at system Turn the power switch to the off position and reseat panel and LEDs on the the power cable in the system power supply unit are not lit or do not remain lit continuously Power cable not fully seated at source Turn the switch to the off position and reseat the power cable at the power source Power source is faulty Turn the switch to the off position connect the power cable to another power source if available and turn the switch back on Faulty power cable Turn the switch to the off position remove the cable and replace it Faulty power supply If the system still fails to come up when the power supply is connected to a different power source with a new power cable the power supply unit is probably faulty
32. wires to the 2700 W power supply terminal block in this order e Ground e Negative e Positive Note When you tighten the terminal nuts make sure they are snug Do not over tighten them Recommended torque strength is 20 inch pounds Over tightening the terminal nuts can break the terminal block Maximum torque 36 inch pounds OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter9 Removal and Replacement Procedures HZ Removing and Replacing the Fan Assembly Step 8 Step 9 amp Figure 9 6 DC Input Wires on Left Side gt ne a Is l He D 132220 When installing the unit the ground connection must always be made first and disconnected last Secure the ground cable to the cable holder with the two cable ties Retrieve the cable holder covers from the plastic bag and attach to the front panel at the locations shown in Figure 9 3 Note Step 10 Step 11 If the cable holder illustrated as number 5 and 8 in Figure 9 3 does not hold the DC input cables snugly please use a long cable tie to secure the cable holders as illustrated in number 9 Secure the terminal block cover using four screws and the terminal block barriers with two screws each Turn on the DC inputs and verify power supply operation by checking the power supply front panel LEDs The power supply rear panel LEDs should be in the following states e INPUT OK
33. 0 1 Links 1 and 2 e Cisco SCE8000 2 Links 3 and 4 The actual connections might look like this e S 0 1 Cisco SCE8000 1 3 0 0 e N 2 2 Cisco SCE8000 1 3 1 0 e S 0 2 Cisco SCE8000 1 3 2 0 e N 3 1 Cisco SCE8000 1 3 3 0 e S 1 3 Cisco SCE8000 2 3 0 0 e N 3 2 Cisco SCE8000 2 3 1 0 e S 1 5 Cisco SCE8000 2 3 2 0 e N 3 4 Cisco SCE8000 2 3 3 0 Single Router with N 1 Redundancy MGSCP Connectivity In order to have N 1 redundancy we must add one extra SCE platform as the standby platform We also must add two more ports on each EC to be used as standby ports In this case we would use three SCE platforms two on the traffic links and one for redundancy which would be connected to the standby ports If we added ports 0 3 and 2 3 on EC1 and 2 4 and 4 4 on EC2 the ECs would look like this e EC1 0 1 0 2 0 3 1 3 1 5 2 3 e EC2 2 2 2 4 3 1 3 2 3 4 4 4 The standby ports must be the two highest numbered ports e ECI standby ports 1 5 2 3 e EC2 standby ports 3 4 4 4 The traffic ports would be assigned to the links as follows OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter 6 Cabling the Line Ports and Completing the Installation HZ Connecting the Line Ports to the Network Link 1 S 0 1 N 2 2 Link 2 S 0 2 N 2 4 Link 3 0 3 N 3 1 Link 4 S 1 3 N 3 2 The standby ports would be assigned to the links as follows Link 5 standby S 1 5 N 3 4 Link 6 s
34. 00 Software Configuration Guide e Cisco SCE8000 CLI Command Reference The procedures for managing Cisco SCE8000 configurations are explained in the following sections e Viewing Configurations page 7 5 e Saving or Changing the Configuration Settings page 7 6 e Restoring a Previous Configuration page 7 8 Viewing Configurations Step 1 When you enter configuration commands it immediately affects the SCE platform operation and configuration This configuration referred to as the running config is saved in the SCE platform volatile memory and is effective while the SCE platform is up After reboot the SCE platform loads the startup config which includes the non default configuration that was saved by the user into the running config The SCE platform provides commands for e Viewing the running configuration with only user configured non default values show running config e Viewing the running configuration with all the SCE platform running configuration values whether default or not show running config all data e Viewing the startup configuration show startup config After configuring the SCE platform you may query for the running configuration using the command show running config At the Cisco SCE8000 prompt type show running config The system shows the running configuration SCE8000 gt show running config This is a general configuration file running config Created on 12 06 13 UTC SUN May 11 2008 cli
35. 00 traffic processor PID VID SN NAME SCE8000 traffic processor 9 DESCR SCE8000 traffic processor PID VID SN NAME SCE8000 traffic processor 10 DESCR SCE8000 traffic processor PID VID SN NAME SCE8000 traffic processor 11 DESCR SCE8000 traffic processor PID VID gN NAME SCE8000 traffic processor 12 DESCR SCE8000 traffic processor Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 a 7415 Chapter7 Basic Cisco SCE8000 Platform Operations W How to Display the System Uptime How to Display the System Uptime Use this command to see how long the system has been running since the last reboot Step 1 At the SCE gt prompt type show system uptime and press Enter Example for Displaying the System Uptime The following example shows how to display the system uptime of the SCE platform SCE show system uptime Cisco SCE8000 uptime is 21 minutes 37 seconds Rebooting and Shutting Down the SCE Platform e Rebooting the SCE Platform page 7 16 e How to Shut Down the SCE Platform page 7 17 Rebooting the SCE Platform Rebooting the SCE platform is required after installing a new package in order for that package to take effect There might be other occasions where rebooting the SCE platform is necessary amp Note When the SCE restarts it loads the startup configuration so all changes made in t
36. 000 SCM E page 2 2 e How to Set Up the Local Console page 5 1 e Initial Setup Parameters page 5 2 e Connecting the Management Interface page 5 4 How to Set Up the Local Console Even if you will be managing the Cisco SCE8000 from a remote location you must first connect the unit to a local console and configure the initial settings for the Cisco SCE8000 to support remote management When the initial connection is established the setup utility will run automatically prompting you to perform the initial system configuration This section provides instructions for setting up your local terminal at your workstation to enable you to perform the initial system configuration of the Cisco SCE8000 system using the setup utility Make sure that the terminal configuration is as follows e 9600 baud e 8 data bits e No Parity e 1 stop bits e No flow control The above Cisco SCE8000 port parameters are fixed and are not configurable OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter5 Connecting the Management Interfaces W initial Setup Parameters Step 1 Step 2 Step 3 Step 4 Step 5 Plug the RS 232 serial cable provided with the Cisco SCE8000 into the CON port on the front panel of the SCE8000 SCM E See item 2 in Figure 5 1 below Figure 5 1 Connecting the Local Console to the SCE8000 SCM E CON Port 270976 Make sure that you push on the RJ 45 connector attached
37. 10GBE Line Interface Ports Step 2 Step 3 Step 4 Step 5 Using a cable with LC connectors on both ends plug one end into the appropriate port C or D on the external bypass module and the other end into the appropriate 1OGBE interface in slot 3 of the SCE8000 chassis Using the control cable provided which has RJ11 connectors on both ends plug one end into the CNTRL interface on the external bypass module see Figure 6 3 and plug the other end into the External Bypass interface on the SCE8000 SCM E in slot 1 of the SCE8000 chassis see item 1 in Figure 6 4 below If using only one external bypass module use External Bypass port 1 If using two external bypass modules use both External Bypass ports on the SCE8000 SCM E in slot 1 Complete the installation and powering up of the SCE8000 By its nature the optic bypass module will not connect the link to the SCE8000 SIP module until the entire SCE8000 system is fully functional It is necessary to bring the SCE8000 to fully operational non bypassed status in order to confirm correct functioning of the link through the optic bypass module to the SCE8000 SIP module Verify link connectivity by checking that the link LED on the 1OGBE interface is green or by using the SCE8000 command line Figure 6 3 Cabling the CNTLR Interface on the External Bypass Module 270977 Figure 6 4 Cabling the SCE8000 SCM E Module 270976 Cisco SCE8000 Installation and Configuratio
38. 16A Figure 4 7 America locking WLK plug 200 240 VAC operation Japan North CAB 7513AC 14 feet 4 3 m 125VAC 20A Figure 4 8 America 100 120VAC operation South Africa CAB 7513ACSA 14 feet 4 3 m 250VAC 16A Figure 4 9 Switzerland CAB ACS 16 14 feet 4 3 m 250VAC 16A Figure 4 10 Australia New CAB AC 16A AU 14 feet 4 3 m 250VAC 16A Figure 4 11 Zealand S Power Distribution CAB C19 CBN 14 feet 4 3 m 250VAC 16A Figure 4 12 Unit PDU The PDU power cable is designed for users who power their switch from a PDU The end of the cable that plugs into the Cisco SCE8000 chassis has a C19 connector the other end of the cable that plugs into the PDU has a C20 connector OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter 4 Installing the Cisco SCE8000 Chassis W Preparing for Installation AC Power Cord Illustrations This section contains the AC power cord illustrations Figure 4 1 AC Power Cord Plugs and Appliance Coupler for the 2700 W Power Supply International 1900W power supply EN 60309 16A 250V North America Non locking NEMA 6 20 plug 20A 250V North America Locking 1900W power supply NEMA L6 20 plug 20A 250V 1900W power supply Europe VIIG plug CEE 7 VII 16A Figure 4 2 CAB AC16A CH ie Appliance coupler C19W coupler Hot EN60320 C19 20A 68142
39. 1OGBE Line Interface Ports page 6 10 e Cabling the 1OGBE Line Interface Ports Using the External Optical Bypass Module page 6 11 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 lt Chapter6 Cabling the Line Ports and Completing the Installation WE Cabling the 10GBE Line Interface Ports Fiber Specifications The following table presents the fiber specifications The Cisco SCE8000 may be ordered with either multi mode or single mode transceivers The transceiver type is indicated on the front panel under the ports Note that all transceivers on any individual Cisco SCE8000 are the same mode either 850nm multi mode OR 1310nm single mode Table 6 1 Fiber Specifications Typical Max SCE Model Transceiver Transmit Power Receive Power Distance Cisco SCE8000 850nm 9 5 to 4 dBm 17 to 0 dBm e 750m for 10GBE MM multi mode 50um Core Diameter MMF e 400m for 62 5um Core Diameter MMF Cisco SCE8000 1310nm FRP laser 9 5 to 3 dBm 20 to 3 dBm 10 km for 9 0um 10GBE SM single mode Core Diameter SMF Optical Device Maintenance Any contamination of the fiber connection can cause failure of the component or failure of the whole system A particle that partially or completely blocks the core generates strong back reflections which can cause instability in the laser system Inspection cleaning and reinspection are critical steps to take before making fiber optic connections H
40. 2 PID SPA 1X10GE L V2 VID V02 SN JAE11517RIO Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter7 Basic Cisco SCE8000 Platform Operations How to Display the SCE Platform Inventory W NAME SPA 1X10GE L V2 DESCR SPA 1X10GE L V2 PID SPA 1X10GE L V2 VID V02 SN JAE115295HH NAME SCE8000 FAN 1 DESCR FAN MOD 4HS PID FAN MOD 4HS VID VO SN DCH11013744 NAME SCE8000 AC or DC power supply 0 DESCR PWR 2700 AC 4 PID PWR 2700 AC 4 VID VO SN APQ105000MV NAME SCE8000 AC or DC power supply 1 DESCR PWR 2700 AC 4 PID PWR 2700 AC 4 VID VO SN APQ105000MV 4 NAME XFP 10GLR OC192SR DESCR XFP 10GLR OC192SR PID XFP 10GLR OC192SR VID V02 SN AGA1142N4B7 7 NAME XFP 10GLR OC192SR DESCR XFP 10GLR 0C192SR PID XFP 10GLR 0C192SR VID V02 SN AGA1142N4AL NAME XFP 10GLR OC192SR DESCR XFP 10GLR 0C192SR PID XFP 10GLR 0C192SR VID V02 SN AGA1141N43R NAME XFP 10GLR OC192SR DESCR XFP 10GLR 0C192SR PID XFP 10GLR OC192SR VID V02 SN AGA1143N4JN Displaying the Complete SCE Platform Inventory The following example shows how to display the complete inventory UDIs of the SCE platform SCE gt show inventory raw SCE8000 Chassis DESCR CISCO7604 PID CISCO7604 VID V01 SN FOX105108X5 NAME SCE8000 Physical Slot 1
41. 478 02 Chapter8 Troubleshooting Troubleshooting with the User Log W How to View the User Log Counters There are two types of log counters e User log counters count the number of system events logged from the SCE platform last reboot e Non volatile counters are not cleared during boot time Step1 From the SCE prompt type show logger device user file log counters and press Enter How to View the Non volatile Counter For the User file log Only Step1 From the SCE prompt type show logger device user file log nv counters and press Enter Generating a File for Technical Support In order for technical support to be most effective the user should provide them with the information contained in the system logs Use the logger get support file command to generate a support file for the use of Cisco technical support staff Step 1 From the SCE prompt type logger get support file filename and press Enter The support information file is created using the specified filename This operation may take some time Step2 To copy the support file to an external source from the SCE prompt type copy filename ftp username password ipaddress path and press Enter Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 a 313 Chapter8 Troubleshooting E Troubleshooting with the User Log Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 Pei OL 16478 02 A CHAPTER
42. 7 I oL 16478 02 g o3 Chapter9 Removal and Replacement Procedures W Removing and Replacing the Power Supply Figure 9 1 AC Power Supply Captive Installation Screws S L1 0 ELLA Ams PRIOR TO ones Must Captive installation screws 126565 Captive installation screws Step5 Grasp both power supply handles as shown in Figure 9 2 and slide the power supply completely out of the chassis Figure 9 2 Handling the AC Power Supply 63901 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oa E OL 16478 02 _ Chapter 9 Removal and Replacement Procedures Removing and Replacing the Power Supply W Installing an AC Input Power Supply A Warning Step 1 Step 2 Step 3 Step 4 A This product requires short circuit over current protection to be provided as part of the building installation Install only in accordance with national and local wiring regulations Ensure that the system earth ground connection has been made For ground connection instructions see Connecting the System Ground page 4 16 Verify that the power switch is in the Off 0 position Grasp both power supply handles as shown in Figure 9 2 Slide the power supply into the power supply bay Make sure that the power supply is fully seated in the bay Securely tighten the power supply captive installa
43. 7 2 e Final Tests page 7 3 Checking Conditions Prior to System Startup Check the following conditions before you start your Cisco SCE8000 platform e Both power supply units are installed and connected If only one power supply is connected it will put the box in warning state e First time startup at installation Cisco SCE8000 platform connected to local console CON port The console terminal is turned on and properly configured e Subsequent startups Line interfaces are properly cabled optional Cisco SCE8000 platform is connected to at least one of the following types of management stations Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 EN Chapter7 Basic Cisco SCE8000 Platform Operations W Starting the Cisco SCE8000 Platform Direct connection to local console CON port Remote management station via the LAN Mng port Performing Complex Configurations After you have installed your Cisco SCE8000 platform hardware checked all external connections turned on the system power allowed the system to boot up and performed the initial system configuration you might need to perform more complex configurations which are beyond the scope of this publication For further information on system and interface configuration refer to the following documents e Cisco SCE8000 Software Configuration Guide e Cisco SCE8000 CLI Command Reference Starting the System and Obser
44. 8000 SCM E is equipped with one active RJ 45 management port This port provides access from a remote management console to the Cisco SCE8000 via a LAN The procedures for cabling the GBE management port and testing connectivity between the Cisco SCE8000 and the remote management host are explained in the following sections e How to Cable the Management Port page 5 4 e How to Verify Management Interface Connectivity page 5 5 How to Cable the Management Port The SCE8000 SCM E has one GBE port that is used as the management port located in slot 1 of the Cisco SCE8000 chassis and labeled Port1 Step 1 Plug the Ethernet cable provided with attached RJ 45 connector into Port lon the front panel of the SCE8000 SCM E See item 3 in Figure 5 2 below Figure 5 2 Cabling the Management Port 270976 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 a E OL 16478 02 Chapter 5 Connecting the Management Interfaces Step 2 Connecting the Management Interface W Connect the other end of the Ethernet cable into your management network Make sure that you push on the RJ 45 connector attached to the cable until you hear a click which indicates that the connector is fully inserted and secured in the receptacle Gently pull on the plug to confirm whether the plug is locked into the socket If the Link LED on the port does not light try removing the cable and reinserting it firmly into the module socket T
45. Ajaj CISCO Cisco SCE8000 Installation and Configuration Guide Release 3 1 7 December 2008 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 Customer Order Number Text Part Number OL 16478 02 THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE ALL STATEMENTS INFORMATION AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND EXPRESS OR IMPLIED USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California Berkeley UCB as part of UCB s public domain version of the UNIX operating system All rights reserved Copyright 1981 Regents of the University of California NOTWITHSTANDING ANY OTHER WARRANTY HEREIN ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED AS IS WITH ALL FAULTS CISCO AND THE ABOVE NAMED SUPPLIERS DISCLAIM ALL WARRANTIES EX
46. Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 a Chapter3 Cisco SCE8000 Topology and Topology Related Parameters E Topology Considerations amp Will the system be used solely to monitor traffic flow with report functionality only or will it be used for traffic flow control with enforcement as well as report functionality Monitoring and Control The Cisco SCE8000 monitors and controls traffic flow Decisions are enforced by the Cisco SCE8000 depending on the results of the monitoring functions of the Cisco SCE8000 and the configuration of the Service Control Application for Broadband or Mobile solution In order to perform control functions the Cisco SCE8000 must be physically installed as an inline installation Monitoring only The Cisco SCE8000 monitors traffic flow but cannot control it Either an inline installation or an optical splitter or port SPAN installation may be used for monitoring only Size A Cisco SCE8000 deployment can range from a single 1OGBE link to multiple platforms in a MGSCP topology A complete discussion on sizing the system is beyond the scope of this document Information regarding the number of Cisco SCE8000 platforms required is related to the design considerations per link topology and redundancy factors rather than to overall sizing of the system Redundancy Must the system be designed to guarantee uninterrupted Cisco SCE8000 functional
47. Contact a service representative Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 a 87 Chapter8 Troubleshooting HI Troubleshooting Overview Troubleshooting the Firmware Package Installation Check the following to help isolate a problem in the installation of the firmware package Problems related to the installation of the firmware package could be any of the following e File not found in the expected location e Wrong file type e Device to which the file is to be extracted is full Table 8 6 Troubleshooting the Firmware Package Installation Diagnostic Action Enter the CLI command e configure e boot system lt filename gt Symptom Possible Cause Possible Solution Returned error is The package file does not exist in the Verify package file location and try Error File lt filename gt does not specified location agamn exist In the output of the command the Package file platform mismatch Verify that you have the package file package file platform is not the appropriate to your platform type correct installation file for the Cisco SCE8000 Troubleshooting the Management Subsystem Check the following to help isolate a problem in the management subsystem Problems in the management subsystem could be any of the following e Management link is down Mng LINK LED not lit also Status is WARNING e Management link is up Mng LINK LED lit but does not
48. E NAME NAME NAME NAME NAME NAME SCE8000 SPA Interface Processor SIP in slot 3 DESCR SCE8000 SIP VID V01 SN CAT1150G07F SCE8000 Link 0 DESCR SCE8000 Link u VID SN SCE8000 Link 1 DESCR SCE8000 Link u VID SN SCE8000 SIP bay 3 0 DESCR SCE8000 SIP bay u VID SN SCE8000 SIP bay 3 1 DESCR SCE8000 SIP bay u VID SN SCE8000 SIP bay 3 2 DESCR SCE8000 SIP bay wo VID SN SCE8000 SIP bay 3 3 DESCR SCE8000 SIP bay u VID SN SCE8000 SPA module 3 0 DESCR SPA 1X10GE L V2 SPA 1X10GE L V2 VID V02 SN JAE11517RMR SCE8000 SPA module 3 1 DESCR SPA 1X10GE L V2 SPA 1X10GE L V2 VID V02 SN JAE11496E1P SCE8000 SPA module 3 2 DESCR SPA 1X10GE L V2 SPA 1X10GE L V2 VID V02 SN JAE11517RIO SCE8000 SPA module 3 3 DESCR SPA 1X10GE L V2 SPA 1X10GE L V2 VID V02 SN JAE115295HH TenGigabitEthernet3 0 0 DESCR SCE8000 SPA port wu VID SN TenGigabitEthernet3 1 0 DESCR SCE8000 SPA port n VID SN TenGigabitEthernet3 2 0 DESCR SCE8000 SPA port n _ VID SN TenGigabitEthernet3 3 0 DESCR SCE8000 SPA port n VID gN SCE8000 FAN 1 DESCR FAN MOD 4HS FAN MOD 4HS VID V01 SN DCH11013744 SCE8000 AC power supply 0 DESCR PWR 2700 AC 4 PWR 2700 AC 4 VID V02 SN APQ1O5000MV SCE8000 DC power
49. E8000 from its peer continuous green peers e No traffic received 1OGBE interface Rx LED is not flashing Troubleshooting with the User Log The user log is an ASCII file that can be viewed in any editor It contains a record of system events including startup shutdown and errors You can use the Logger to view the user log to determine whether or not the system is functioning properly as well as for technical support purposes e The Logging System page 8 11 e Generating a File for Technical Support page 8 13 The Logging System Events are logged to one of two log files After a file reaches maximum capacity the events logged in that file are then temporarily archived New events are then automatically logged to the alternate log file When the second log file reaches maximum capacity the system then reverts to logging events to the first log file thus overwriting the temporarily archived information stored in that file Basic operations include e Copying the User Log to an external source e Viewing the User Log e Clearing the User Log e Viewing clearing the User Log counters Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 ast Chapter8 Troubleshooting WE Troubleshooting with the User Log e How to Copy the User Log to an External Source page 8 12 e How to Copy the User Log to an Internal Location page 8 12 e How to View the User Log page 8 12 e How to Clear the Use
50. Figure 3 3 Dual link Inline Installation Subscriber 1 Subscriber 2 270589 This topology supports both monitoring and control functionality and is referred to as inline connection mode Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 EN OL 16478 02 Chapter3 Cisco SCE8000 Topology and Topology Related Parameters Physical Topologies W Single Link Receive only Topology In this topology an optical splitter resides physically on the 1OGBE link between the subscribers and the network The traffic passes through the optical splitter which splits traffic to the Cisco SCE8000 The Cisco SCE8000 therefore only receives traffic and does not transmit Figure 3 4 Single Link Receive only Topology Subscriber Splitter 270586 When configuring the Cisco SCE8000 an optical splitter topology is referred to as receive only connection mode Note that in an optical splitter topology the Cisco SCE8000 only enables traffic monitoring functionality Note When implementing receive only topologies with a switch the switch must support SPAN functionality that includes separation between ingress and egress traffic and multiple SPAN ports destinations Dual Link Receive Only Topology In this topology one Cisco SCE8000 is connected in receive only mode to two full duplex 10 Gig links using optical splitters If the two links are load shared asymmetrical routing might occur a
51. LED is green e FAN OK LED is green e OUTPUT FAIL LED is not lit If the LEDs indicate a power problem see Identifying Startup Problems page 8 6 Removing and Replacing the Fan Assembly This section describes how to remove and replace fan assemblies for the Cisco SCE8000 chassis e Required Tools page 9 10 e Removing the Fan Assembly page 9 11 e Installing the Fan Assembly page 9 11 Required Tools A flat blade or number 2 Phillips head screwdriver is required to perform this procedure E Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter9 Removal and Replacement Procedures Removing and Replacing the Fan Assembly W Removing the Fan Assembly The fan assembly is designed to be removed and replaced while the system is operating without presenting an electrical hazard or damage to the system Step 1 Loosen the two captive installation screws by turning them counterclockwise Figure 9 7 Fan Assembly KJ TIQ e e 270893 met Captive installation screws When removing the fan tray keep your hands and fingers away from the spinning fan blades Let the fan blades completely stop before you remove the fan tray Step2 Grasp the fan assembly with both hands and pull it outward rock it gently if necessary to unseat the power connector from the backplane Step3 Pull the fan assembly clear of the chassis and put it in a s
52. PRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING USAGE OR TRADE PRACTICE IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES INCLUDING WITHOUT LIMITATION LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES CCDE CCENT Cisco Eos Cisco HealthPresence the Cisco logo Cisco Lumin Cisco Nexus Cisco StadiumVision Cisco TelePresence Cisco WebEx DCE and Welcome to the Human Network are trademarks Changing the Way We Work Live Play and Learn and Cisco Store are service marks and Access Registrar Aironet AsyncOS Bringing the Meeting To You Catalyst CCDA CCDP CCIE CCIP CCNA CCNP CCSP CCVP Cisco the Cisco Certified Internetwork Expert logo Cisco IOS Cisco Press Cisco Systems Cisco Systems Capital the Cisco Systems logo Cisco Unity Collaboration Without Limitation EtherFast EtherSwitch Event Center Fast Step Follow Me Browsing FormShare GigaDrive HomeLink Internet Quotient IOS iPhone iQuick Study IronPort the IronPort logo LightStream Linksys MediaTone MeetingPlace MeetingPlace Chime Sound MGX Networkers Networking Academy Network Registrar PCNow PIX PowerPanels ProConnect ScriptShare SenderBase SMAR
53. R 850 nm MMF The SCE8000 SIP Table 2 5 SCE8000 SIP LED LEDs Description Status e Green Operational e Flashing Amber Electrical bypass in operation e Red Not initialized or failed e Unlit No power The 1 Port 10GBE SPA Interface Module The SCE8000 SIP is installed in slot 3 of the Cisco SCE8000 chassis It hosts up to four single width single height 1 Port 10GBE SPA interface modules but in the Cisco SCE8000 it must be configured with either two 1 Port 10GBE SPAs in the top two subslots or four 1 Port 10GBE SPAs to provide interfaces for either one or two complete traffic links Figure 2 6 1 Port 10GBE SPA Interface Module imj U U fa all U Army mtr U LL U U LL U U Mf flan fl a a rm U KN P 5 wo O gt SPA 1X1 OGE L V2 4 N l 122151 OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter2 Introduction to the Cisco SCE8000 Platform E The Cisco SCE8000 Optical Bypass Table 2 6 SPA Ports Port Quantity Description Connect This Port To 10 GBE Line 1 on each SPA Any one of the following Any one of the following port e XFP e Subscriber side network XFP 10GLR OC192SR component 10km e Network sid
54. Rack W Figure 4 14 Installing the Cisco SCE8000 Chassis in the Rack g eS gn H ie ie 0 ie ie o o Im ie ie ne o Q o ie 0 o ie o o ie 0 o ie ie o Q ie o ie ie o 9 ie O ie o 0 Q QO 0 0 _ 4 Step4 Install the eight four per side 12 24 x 3 4 inch or 10 32 x 3 4 inch screws through the holes in the bracket and into the threaded holes in the equipment rack posts Step5 Use a tape measure and level to verify that the chassis is installed straight and level Installing an Optical Bypass Module There are two installation options for the external bypass modules e Chassis mount panel This panel is mounted on slot 4 of the SCE8000 chassis It hosts two optical bypass modules which will serve the two traffic links supported by one Cisco SCE8000 chassis e External mounting panel This panel can be mounted in any 19 rack It hosts up to four optical bypass modules which will serve the four traffic links supported by two Cisco SCE8000 platforms Step 1 For external mounting install the external mounting panel in the 19 rack Screw the mounting panel to the rack using four 3 4 inch screws two on each side through the holes in the mounting panel and into the threaded holes in the rack posts For internal mounting the SCE8000 chassis will be shipped with the chassis mounting panel already
55. Subscriber Switch II gt RX TX a DN amp Note In the above configuration it is essential that the SCE8000 be operating in receive only mode Other configurations may cause SPAN port traffic to be returned to the switch causing unpredictable behavior Unsupported Configuration Due to the 10GBE characterstics described above the following configuration is not supported in the 10 GBE environment In this configuration the switch port remains in the DOWN state and therefore does not transmit Figure A 3 Unsupported SPAN Port Configuration Subscriber Switch m gt RX TX Erg m 270987 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 a OL 16478 02
56. TenGigabitEthernet interfaces stands for the number of the SPA module Problems in the link interface subsystem could be any of the following e Link is down LINK LED not lit and system status is WARNING e Peer does not receive traffic from Cisco SCE8000 LINK LED is lit and Tx LED is flashing e 1OGBE link is up but not receiving from peer LINK LED is lit but Rx LED is not flashing Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter8 Troubleshooting Troubleshooting with the User Log W Table 8 8 Troubleshooting the Link Interface Subsystem Symptom Diagnostic Action Possible Cause Possible Solution e Link is down LINK CLI command Connector is not connected to Reconnect the fiber to the LED not lit show interface the platform or to the network 10GBE port and to network e Output counters not TenGigabitEthernet incrementing 3 0 counters Fiber is broken or damaged Reconnect replace the fiber to the 10GBE port Connectivity using external Reconnect replace the fiber optic bypass is incorrect or between the 10GBE port and problematic the optic bypass module Temporarily disconnect optic Problem with external optic Replace the optic bypass bypass module and check bypass module module operation See Cabling the 10GBE Line Interface Ports page 6 9 e 1OGBE link is up No traffic is being transmitted to Check traffic connection at LINK LED is the Cisco SC
57. Tnet Spectrum Expert StackWise The Fastest Way to Increase Your Internet Quotient TransPath WebEx and the WebEx logo are registered trademarks of Cisco Systems Inc and or its affiliates in the United States and certain other countries All other trademarks mentioned in this document or website are the property of their respective owners The use of the word partner does not imply a partnership relationship between Cisco and any other company 0812R Any Internet Protocol IP addresses used in this document are not intended to be actual addresses Any examples command display output and figures included in the document are shown for illustrative purposes only Any use of actual IP addresses in illustrative content is unintentional and coincidental Cisco SCE8000 Installation and Configuration Guide 2008 Cisco Systems Inc All rights reserved About this Guide ix cHapTerR 1 Cisco Service Control Overview 1 1 Cisco Service Control Solution 1 1 Service Control for Broadband Service Providers 1 1 Cisco Service Control Capabilities 1 2 SCE Platform Description 1 3 Management and Collection 1 5 Network Management 1 5 Subscriber Management 1 6 Service Configuration Management 1 6 Data Collection 1 6 CHAPTER 2 Introduction to the Cisco SCE8000 Platform 2 1 Information About the SCE Platform 2 1 Service Control Module SCE8000 SCM E 2 2 Introduction to SIPs and SPAs 2 4 SPA Interface Processors 2 4 Specifying the SIP Subslot
58. active kernel 1 0 0 5 u boot uboot 1 0 0 6 field uboot 0 8 1 13 select ubs cf1 1 0 0 5 secondary Slot 1 SCM 8000 serial num CAT1202G07D part num 73 10598 01 38 cpld 0x8162 vtpld 0xc001 summit 0 0x10008 summit 1 0x10008 dpt tx 0x4837 cls ff 0x2047 cls flow cap 33554432 cpus 1 cpu SVR 0x80900120 cpu PVR 0x80040202 cpu freq 1000MHz cpu eeprom 2 1 1000MHz cpld Oxalb7 cpld ufm 0xa803 summit 0x10007 cf Model SMART CF FwRev 0x20060811 cpu 0 SVR 0x80900121 cpu 0 PVR 0x80040202 cpu 0 freq 1500MHz cpu 1 SVR 0x80900121 cpu 1 PVR 0x80040202 cpu 1 freq 1500MHz cpu 2 SVR 0x80900121 cpu 2 PVR 0x80040202 cpu 2 freq 1500MHz cpu eeprom 2 1 1500MHz cpld 0 Oxb20e cpld 1 Oxb20e cpld 2 Oxb20e cpld 0O ufm 0xb803 cpld 1 ufm 0xb803 cpld 2 ufm 0xb803 summit 0 0x1000a summit 1 0x1000a fc 0x1044 board type P2 ubs cf1 1 0 0 5 Size 4062240KB E Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter 7 Basic Cisco SCE8000 Platform Operations How to Display the SCE Platform Version Information cpus 3 cpu 0 SVR 0x80900121 cpu 0 PVR 0x80040202 cpu 0 freq 1500MHz cpu 1 SVR 0x80900121 cpu 1 PVR 0x80040202 cpu 1 freq 1500MHz cpu 2 SVR 0x80900121 cpu 2 PVR 0x80040202 cpu 2 freq 1500MHz cpu eeprom 2 1 1500MHz cpld 0 Oxb20e cpld 1 0xb20e
59. afe place Installing the Fan Assembly Step 1 Hold the fan assembly with the fans facing to the right and the FAN STATUS LED at the bottom See Figure 9 7 Step2 Place the fan assembly into the front chassis cavity so that it rests on the chassis and then lift the fan assembly up slightly aligning the top and bottom chassis guides Step3 Push the fan assembly into the chassis until the power connector seats in the backplane and the captive installation screws make contact with the chassis Step4 Tighten the captive installation screws Step5 Verify that fans are operational Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 Te Chapter9 Removal and Replacement Procedures HZ Removing and Replacing Modules e Listen for the fans you should immediately hear them operating If you do not hear them ensure that the fan assembly is inserted completely in the chassis and the faceplate is flush with the switch back panel e Verify that the FAN STATUS LED is green If the LED is red one or more fans is faulty Removing and Replacing Modules The Cisco SCE8000 platform supports two types of modules e Service Control Module SCE8000 SCM E e SPA Interface Processor SCE8000 SIP The following diagram shows the position of these modules in the Cisco SCE8000 chassis Figure 9 8 Slot Numbers on Cisco SCE8000 Chassis SCE8000 SCMs SCE8000 SIP 270889 Opt
60. affic to flow via the Cisco SCE8000 e Under failure conditions the optical bypass shortcuts the interfaces that are connected to the traffic link and all traffic flows through the optical bypass module bypassing the SCE platform Figure 2 7 Optical Bypass Module Connectivity Default bypass state no power Tedin Non default bypass state Ss S 3 0 0 amu 3 1 0 EN aag 3 Occes000 22 1 OPB os S 242125 Optical Bypass Module OPB SCE8K There are two types of optical bypass modules to support different optic types e OPB SCE8K SM supports Single Mode optics and should be used with SCE8000 equipped with Single Mode optics Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 29 Chapter 2 Introduction to the Cisco SCE8000 Platform E The Cisco SCE8000 Optical Bypass e OPB SCE8K MM supports Multi Mode optics and should be used with SCE8000 equipped with Multi Mode optics The optical bypass module is installed either internally in slot 4 of the Cisco SCE8000 chassis or in an external mounting panel in the rack Up to two optical bypass modules can be mounted internally supporting inline insertion into two links Up to four optical bypass modules can be mounted using an external mount panel OPB SCE8K EXT PNL A single panel can serve two SCE8000 platforms each cuttin
61. agement The Cisco service control solution provides complete network Fault Configuration Accounting Performance Security FCAPS Management Two interfaces provide network management e Command line interface CLI Accessible through the Console port or through a Telnet connection the CLI is used for configuration and security functions e SNMP Provides fault management through SNMP traps and performance monitoring functionality OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter1 Cisco Service Control Overview HE Management and Collection Subscriber Management Where the Cisco service control application for broadband SCA BB enforces policies on different subscribers and tracks usage on an individual subscriber basis the Cisco service control management suite SCMS subscriber manager SM may be used as middleware software for bridging between OSS and SCE platforms Subscriber information is stored in the SM database and can be distributed between multiple platforms according to actual subscriber placement The SM provides subscriber awareness by mapping network IDs to subscriber IDs It can obtain subscriber information using dedicated integration modules that integrate with AAA devices such as RADIUS or DHCP servers Subscriber information may be obtained in one of two ways e Push Mode The SM pushes subscriber information to the SCE platform automatically upon logon
62. ame Default Global Controller interface TenGigabitEthernet 3 3 0 bandwidth 10000000 burst size 50000 global controller 0 name Default Global Controller exit ip default gateway 10 56 96 1 line vty 0 4 exit management agent property com pcube management framework install activation operation Install management agent property com pcube management framework install activated package SCA BB management agent property com pcube management framework install activated version 3 1 6 build 79 management agent property com pcube management framework install activation date Sun May 11 08 44 04 GMT 00 00 2008 flow filter partition name ignore_filter first rule 4 num rules 32 flow filter partition name udpPortsToOpenBySw first rule 40 num rules 21 Saving or Changing the Configuration Settings When you make changes to the current running configuration and you want those changes to continue to be in effect when the system restarts you must save the changes before leaving the management session You do that by saving the running configuration to the startup configuration file The SCE platform provides multiple interfaces for the purpose of configuration and management All interfaces supply an API to the same database of the SCE platform and any configuration made through one interface is reflected through all interfaces Furthermore when saving the running configuration to the startup conf
63. answer ping e Telnet connection cannot be established due to link problems Mng LINK LED not lit e Management link is up Mng LINK LED lit but Telnet connection cannot be established e Telnet connection established but terminates automatically amp Note When the management link is down and or a Telnet connection cannot be established you must open a CLI session on a local terminal connected to the CON port This enables you to solve the problem and then reconnect through the management port Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 8 8 OL 16478 02 Chapter8 Troubleshooting Troubleshooting Overview W Table 8 7 Troubleshooting the Management Subsystem Possible Cause Possible Solution Diagnostic Action Symptom Management link down e Mng LINK LED not lit e CLI command show interface GigabitEthernet 1 1 e ping to management interface fails RJ 45 connector is not connected to the platform or to the network Reconnect the cable to the GBE port and to network Cable is broken Check Replace the cable Management link up e Mng LINK LED is lit e ping to management interface fails CLI commands e show ip route e show ip default gateway One of the following configurations may be wrong e IP address subnet mask e IP default gateway See Initial Setup Parameters page 5 2 Refer to IP Configuration in the Cisco SCE8000 Software Configur
64. apter8 Troubleshooting HI Troubleshooting Overview Table 8 1 Troubleshooting Strategy for Startup Problems Action Yes No Step 1 Turn power on Go to Step 2 Step 2 Check the following Go to Step 3 Refer to Troubleshooting the Power e Front panel power LED on eal page 8 7 and go to Step e Power supply Input OK LEDs l on e Output fail LEDs not on Step3 Status LED red failure Refer to Troubleshooting the Go to Step 4 Firmware Package Installation page 8 8 and go to Step 4 Step 4 Management interface operational Go to Step 5 Refer to Troubleshooting the Management Subsystem page 8 8 and go to Step 5 Step 5 Link interfaces operational Go to Step 6 Refer to Troubleshooting the Link Interface Subsystem page 8 10 and go to Step 6 Step 6 System startup successful all interfaces operating normally Information About Troubleshooting Tools There are two tools that will help you to successfully troubleshoot your Cisco SCE8000 installation e CLI Commands for Troubleshooting page 8 2 e Checking the LEDs page 8 4 CLI Commands for Troubleshooting Use the following commands to provide information to help you troubleshoot installation of your Cisco SCE8000 platform Refer to Cisco SCE8000 Software Configuration Guide or the Cisco SCE8000 CLI Command Reference for more information amp Note Remember that if the management interface is not operational you should connect t
65. arameters correctly for each topology e The Cisco SCE8000 Platform page 3 1 e Topology Considerations page 3 1 e Physical Topologies page 3 3 e Link Continuity page 3 9 e Topology Related Parameters page 3 11 e Asymmetric Routing Topology page 3 13 The Cisco SCE8000 Platform The Cisco SCE8000 is a solution for dual links with load sharing and asymmetrical routing and support for fail over between two SCE platforms The Cisco SCE8000 is built to support wire speed processing of full duplex 10GBE streams The Cisco SCE8000 can therefore be deployed in a multi link environment in several different topologies e Single Cisco SCE8000 topology Provides the ability to process both directions of a bi directional flow processing both the upstream and downstream paths of a flow even if they traverse different links e Dual Cisco SCE8000 topology cascade Cascaded Cisco SCE8000s provide high availability and fail over solution and maintain the line and service in case of Cisco SCE8000 failure e Multi Gigabit Service Control Platform MGSCP topology For scalability the Cisco SCE8000 platform supports the option to connect a multiple number of SCE platforms to a Cisco 7600 Series router used to perform load balancing between the platforms Topology Considerations There are several issues that must be considered in order to arrive at the optimum configuration of the topology related parameters e Functionality
66. ateway of last resort is 10323251 show access lists Shows all access lists or a specific access list Following is a sample output from the show access lists command Standard IP access list 1 Permit 10 1 1 0 wildcard bits 0 0 0 255 deny any show telnet Displays the status of the telnet server daemon status or any active Telnet sessions sessions Following is a sample output from the show telnet command show telnet sessions There is 1 active telnet session Index Source 0 10 1 1 201 show telnet status Telnet deamon is enabled show line vty timeout Shows the timeout configured for Telnet sessions Following is a sample output from the show line vty timeout command Timeout is 30 minutes Troubleshooting the link interface subsystem show interface TenGigabitEthernet 3 0 Displays information for a specific 1OGBE Interface Following is a sample output from the show interface command Auto negotiation configured Disabled Actual status Link is ON Auto negotiation Disabled Bandwidth L1 10000000 Kbps Burst size 500000 bytes Pseudo IP Address Not Configured show interface TenGigabitEthernet 3 0 counters Displays the values of counters of a GBE interface Following is a sample output from the show interface counters command OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter8 Troubleshooting HI Troublesh
67. atforms MGSCP Topologies 6 4 The Optical Bypass Module 6 8 Optical Bypass Module Connectivity 6 8 Cabling the 10GBE Line Interface Ports 6 9 Fiber Specifications 6 10 Optical Device Maintenance 6 10 How to Cable the 10GBE Line Interface Ports 6 10 Cabling the 10GBE Line Interface Ports Using the External Optical Bypass Module 6 11 Testing Connectivity Examining Link LEDs and Counters 6 13 Examining the LEDs 6 13 How to View the Ten Gigabit Ethernet Port Status 6 13 How to View the Ten Gigabit Ethernet Counters 6 13 How to View the User Log Counters 6 14 How to Load and Activate a Service Control Application 6 14 Contents W Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 ii E Contents Cascaded Systems 6 15 How to Install a Cascaded System 6 15 CLI Commands for Cascaded Systems 6 16 Topology Related Parameters for Redundant Topologies How to Configure the Connection Mode 6 16 How to Set the Link Mode 6 17 Monitoring the System 6 18 CHAPTER 7 Basic Cisco SCE8000 Platform Operations 7 1 Starting the Cisco SCE8000 Platform 7 1 Checking Conditions Prior to System Startup 7 1 Performing Complex Configurations 7 2 Starting the System and Observing Initial Conditions 7 2 What to Do Next 7 2 Final Tests 7 3 Verifying Operational Status 7 3 Viewing the User Log Counters 7 3 Viewing the Ten Gigabit Ethernet Port Status 7 4 Viewing the Ten Gigabit Ethernet Counters 7 4 Managing Cisco SCE8000 Configu
68. ation Guide CLI command show access lists An ACL may be assigned that denies entry See Initial Setup Parameters page 5 2 Refer to Access Control Lists in the Cisco SCE8000 Software Configuration Guide e Telnet connection cannot be established e Mng LINK LED is not lit link is down e CLI command show interface GigabitEthernet 1 1 Management interface IP address or subnet mask is incorrect Check reconfigure management port IP address and subnet mask e Telnet connection cannot be established e Mng LINK LED is lit link is up CLI command show telnet status Telnet server is disabled Enable Telnet server service telnetd CLI command show telnet sessions Too many Telnet connections up to five concurrent sessions are supported via Telnet Close one or more of the open Telnet sessions CLI command s how ip default gateway Default gateway is incorrect when the host used as client is not in the same network as the SCE Platform Check reconfigure default gateway See Initial Setup Parameters page 5 2 Refer to IP Configuration in the Cisco SCE8000 Software Configuration Guide OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter8 Troubleshooting HI Troubleshooting Overview Table 8 7 Symptom Troubleshooting the Management Subsystem Diagnostic Action Possible Cause Possib
69. ation The RSS feeds are a free service and Cisco currently supports RSS version 2 0 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 Pot OL 16478 02 CHAPTER 1 Cisco Service Control Overview This chapter provides a general overview of the Cisco Service Control solution It introduces the Cisco service control concept and capabilities It also briefly describes the hardware capabilities of the service control engine SCE platform and the Cisco specific applications that together compose the complete Cisco service control solution e Cisco Service Control Solution page 1 1 e Cisco Service Control Capabilities page 1 2 e SCE Platform Description page 1 3 e Management and Collection page 1 5 Cisco Service Control Solution The Cisco service control solution is delivered through a combination of hardware and specific software solutions that address various operational and business related challenges Service providers can use the SCE platform to support classification analysis and control of Internet and IP traffic Service control enables service providers to e Capitalize on existing infrastructure e Analyze charge for and control IP network traffic at multigigabit wire line speeds e Identify and target high margin content based services and enable their delivery As access and bandwidth have become commodities where prices continually fall and profits disappear service providers have realized that
70. awareness that relates traffic and usage to specific customers Figure 1 1 illustrates a common deployment of an SCE platform in a network Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 EN Chapter1 Cisco Service Control Overview HZ SCE Platform Description Figure 1 1 SCE Platform in the Network aa Corporate Users Po e fi 5 7 Provider network Peer network amp Internet Aggregation device SCE platform Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 _ Chapter 1 Cisco Service Control Overview Management and Collection Management and Collection The Cisco service control solution includes a complete management infrastructure that provides the following management components to manage all aspects of the solution e Network management e Subscriber management e Service Configuration management These management interfaces are designed to comply with common management standards and to integrate easily with existing OSS infrastructure Figure 1 2 Figure 1 2 Service Control Management Infrastructure Service policy and quota Network management Provisioning management ines system I ml olection Manager ima XML RPC mi CLI and SNMP S Subscrib ubscriber Manager e a Subscriber info DHCP or RADIUS 6 Aggregation SCE platform Router device Network Man
71. cascade topology the user must define the priority of each Cisco SCE8000 e Primary The Primary Cisco SCE8000 is active by default e Secondary The Secondary Cisco SCE8000 is the default standby Note that these defaults apply only when both devices are started together However if the primary Cisco SCE8000 fails and then recovers it will not revert to active status but remains in standby status while the secondary device remains active On Failure Mode Parameter The on failure mode parameter configures the action taken by a failed box when a failure is detected As described in the section Internal Bypass Mechanism page 3 9 the SPA Interface Processor card supports three different modes The Bypass and Cutoff modes are possible when the Cisco SCE8000 is not operational due to platform failure or boot The Forwarding mode enables control of traffic flow and is not compatible with the non operational status The following on failure modes are possible e Bypass The SPA interface card forwards traffic between the two ports of each link with no intervention of the control application running in the Cisco SCE8000 platform This is also known as electrical bypass In a cascade setup this allows the traffic of the link connected to the failed box to be passed to the active box for processing e Cutoff There is no forwarding of traffic The link is forced down resulting in traffic cutoff at Layer e External bypass
72. ce and the platform configuration may or may not be active available Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 aes Chapter8 Troubleshooting HI Troubleshooting Overview Table 8 3 Power Supply LEDs LED Label Color State Function INPUT OK Green On The input voltage is present and within the required range Off The input voltage is not present or not within the required range OUTPUT FAIL Green On The output voltage is not within the required range Off The output voltage is in the required range FAN OK Green On Power supply internal fan is operational Off Power supply internal fan is not operational Power front Green Steady Installed power supplies are functioning normally panel Amber Steady One of the power supply units is disconnected or malfunctioning Off No power Table 8 4 Fan Assembly LED LED Label Color State Function FAN STATUS Green On All fans are operational Off One or more of the individual fans are not operational Problem Solving Using a Subsystems Approach e Identifying Startup Problems page 8 6 e Troubleshooting the Power Subsystem page 8 7 e Troubleshooting the Firmware Package Installation page 8 8 e Troubleshooting the Management Subsystem page 8 8 e Troubleshooting the Link Interface Subsystem page 8 10 Identifying Startup Problems Startup problems are commonly due to the source power or to a po
73. chapter provides instructions for cabling the Gigabit Ethernet ports for both one and two SCE8000 topologies and for configuring Gigabit Ethernet GBE interface parameters In a topology utilizing two SCE8000s cascade this includes the cascade ports as well as the line ports Basic Cisco SCE8000 Platform Operations page 7 1 This chapter describes how to start up the SCE8000 platform reboot and shutdown It also describes how to manage configurations Troubleshooting page 8 1 This chapter provides basic system startup troubleshooting information Removal and Replacement Procedures page 9 1 This chapter explains the procedures for removing and replacing the power supplies fan trays and other modules Using Optical Splitters with 1OGBE Links page A 1 This appendix supplies important information regarding supported and not supported optical splitter configurations in the 10GBE environment Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 About this Guide Related Publications Your SCE8000 platform and the software running on it contain extensive features and functionality which are documented in the following resources e Cisco CLI software Cisco SCE8000 Software Configuration Guide Cisco SCE8000 CLI Command Reference e For initial installation and startup information refer to the Cisco SCE8000 Quick Start Guide e For international agen
74. cribers and the network The subscribers are usually connected through either a BRAS in DSL access a PDSN in wireless access a CMTS in the Cable access or a switch or router aggregator in other topologies The network is a router or layer 3 switch network element connecting the Cisco SCE8000 towards the core of the network Guidelines for single link inline topologies e If only two SPA modules are installed only two SPA modules are required for a single link they must be installed in bays 0 and 1 of the SPA jacket card e Inline topologies require both Receive and Transmit fibers e To maintain link continuity at all times an optical bypass module should be installed Single link inline connectivity e Port 3 0 0 Link 0 Subscribers side e Port 3 1 0 Link 0 Network side Single Link Receive only Topology In this topology an optical splitter unit resides physically on the 10 GBE link that the Cisco SCE8000 should monitor The optical splitter unit is connected to the Cisco SCE8000 Rx links only For each link monitored there will be two Rx connections to the Cisco SCE8000 one for each direction of traffic flow in the link The traffic passes through the optical splitter which allows the Cisco SCE8000 to monitor traffic without affecting the normal optic and data path between subscriber and network amp Note Receive only topologies can also be implemented using a switch Such a switch must support SPAN functionality tha
75. ctory configuration If you have removed or replaced components or changed any default settings the recommendations in this chapter might not apply Make sure to review the safety warnings listed in the Regulatory Compliance and Safety Information for the Cisco SCE8000 document that accompanied your Cisco SCE8000 platform before using the troubleshooting procedures in this chapter e Troubleshooting Overview page 8 1 e Troubleshooting with the User Log page 8 11 Troubleshooting Overview This section describes the troubleshooting methods used in this chapter and describes how the Cisco SCE8000 platform is divided into subsystems for more efficient problem solving If you are unable to easily solve the problem contact a customer service representative for assistance and further instructions Provide the representative with the following information e Date you received the Cisco SCE8000 e Chassis serial number e Type of software and release number e Brief description of the problem you are having e Brief explanation of the steps you have taken to isolate and resolve the problem e Maintenance agreement or warranty information The following table shows the general troubleshooting strategy described in this chapter Refer to this table as necessary to follow the steps to isolate problems to a specific subsystem and resolve the problem if possible Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 sei Ch
76. cy compliance safety and statutory information for wide area network WAN interfaces for the SCE8000 platform refer to the Regulatory Compliance and Safety Information for Cisco SCE8000 e For installation and configuration of the other components of the Service Control Management Suite refer to Cisco SCMS Subscriber Management User Guide Cisco SCMS Collection Manager User Guide Cisco Service Control Application for Broadband User Guide Cisco Service Control Application Reporter User Guide e To view Cisco documentation or obtain general information about the documentation refer to the Cisco Information Packet that shipped with your SCE8000 platform Conventions This document uses the following conventions Convention Indication bold font Commands and keywords and user entered text appear in bold font italic font Document titles new or emphasized terms and arguments for which you supply values are in italic font Elements in square brackets are optional xlylz Required alternative keywords are grouped in braces and separated by vertical bars xlylz Optional alternative keywords are grouped in brackets and separated by vertical bars string A nonquoted set of characters Do not use quotation marks around the string or the string will include the quotation marks courier font Terminal sessions and information the system displays appear in courier font
77. d The connection mode depends on two factors e Inline Receive only Inline The Cisco SCE8000 resides on the data link between the subscriber side and the network side thus both receiving and transmitting packets Receive only The Cisco SCE8000 does not reside physically on the data link Data is forwarded to the Cisco SCE8000 via an external optical splitter The Cisco SCE8000 itself receives only and does not transmit e Cascade Indicates a two Cisco SCE8000 topology where the two Cisco SCE8000 platforms are connected via the cascade ports Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 lt Chapter3 Cisco SCE8000 Topology and Topology Related Parameters E Topology Related Parameters The connection mode parameter is determined by the physical deployment of the Cisco SCE8000 as follows e Single Cisco SCE8000 inline installation Inline connection mode e Single Cisco SCE8000 optical splitter installation Receive only connection mode e Two platform cascaded Cisco SCE8000 inline installation Inline cascade connection mode e Two platform cascaded Cisco SCE8000 optical splitter installation Receive only cascade connection mode Physically Connected Links Parameter A cascade topology supports two traffic links This parameter defines which link is connected to which Cisco SCE8000 platform The links are designated as follows e Link 0 e Link 1 Priority In a
78. dundant Router 63 ou F lt n Ce BJ a SCE8000s pe 4 1 270883 ES M Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 EN OL 16478 02 _ Chapter 3 Cisco SCE8000 Topology and Topology Related Parameters Link Continuity W Link Continuity The internal bypass mechanism of the Cisco SCE8000 allows traffic to continue to flow if desired even if the device itself is not fully functioning In addition the Cisco SCE8000 is designed with the ability to control up to two external optical bypass devices one per link This is needed because the internal bypass mechanism cannot maintain traffic flow in all cases Note that when the Cisco SCE8000 is connected to the network through an optical splitter a failure of the Cisco SCE8000 does not affect the traffic flow as the traffic continues to flow through the optical splitter e Internal Bypass Mechanism page 3 9 e External Optical Bypass page 3 9 Internal Bypass Mechanism The Cisco SCE8000 includes a SPA Interface Processor module with a bypass mechanism that is enabled upon Cisco SCE8000 failure The SPA Interface Processor card supports the following three modes e Bypass The bypass mechanism preserves the network link but traffic is not processed for monitoring or for control e Forwarding This is the normal operational mode in which the Cisco SCE8000 processes the traffic for monitoring and control purposes
79. e Cisco SCE8000 out of band LAN based management port as follows e Link Active Steady green Port link is up Flashing green Activity on the port link Unlit Port link is down e Speed Unlit Port is set to 1OMbps Steady green Port is set to 100 Mbps Steady amber Port is set to 1000 Mbps On a slave SCE8000 SMC_E module in the second slot this LED is always off Introduction to SIPs and SPAs SIPs and SPAs are a new carrier card and port adapter architecture used to increase modularity flexibility and density across Cisco Systems routers for network connectivity This section describes the SIPs and SPAs and provides some guidelines for their use e SPA Interface Processors page 2 4 e Specifying the SIP Subslot Location for a SPA page 2 5 e Shared Port Adapters page 2 5 e Modular Optics page 2 6 e XFP Connections page 2 6 SPA Interface Processors The SIP module supported by the Cisco SCE8000 chassis is the SCE8000 SIP The following list describes some of the general characteristics of a SIP e A SIP is a carrier card that inserts into a slot in the chassis like a line card It provides no network connectivity on its own e A SIP contains one or more subslots bays which are used to house one or more SPAs The SPA provides interface ports for network connectivity e During normal operation the SIP should reside in the router fully populated either with functional SPAs in all subslots or wi
80. e Control Module SCE8000 SCM E The Cisco SCE8000 contains one or two SCE8000 SCMs located in slots 1 and 2 the top two slots The Service Control module contains ports and LEDs as shown in the following figure and tables Figure 2 2 SCE8000 SCM E SCESODD SCME SCES00 EXTENDED SERVICE CONTROL MODULE Cy eames EEA mes OPTICAL BYPASSI i i E cE Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 22 E OL 16478 02 Chapter2 Introduction to the Cisco SCE8000 Platform Service Control Module SCE8000 SCM E W Table 2 2 SCE8000 SCM E Ports Port Quantity Description Connect This Port To GBE port 2 Gigabit Ethernet RJ 45 ports for A LAN using a GBE cable with Currently only management of the Cisco an RJ 45 connector one GBE port SCES000 is supported CLI designation interface GigabitEthernet 1 1 1 2 Console 1 RS 232 RJ 45 port for use by A local terminal console using technicians an RS 232 cable with an RJ 45 connector as provided in the Cisco SCE8000 kit AUX 1 RS 232 RJ 45 port used by technicians Bypass 2 RJ 11 port The Control connector on the optical bypass module Table 2 3 SCE8000 SCM E LEDs LEDs Description Power e Steady green Installed power supplies are functioning normally e Steady amber Only one power supply is functioning normally e Unlit No power from e
81. e ENTITY MIB in the Cisco Service Control Engine SCE Software Configuration Guide e CLI show inventory command This command displays the UDIs only for field replaceable units FRU e CLI show inventory raw command This command displays all UDIs on the Cisco SCE8000 platform The show inventory CLI commands display the following information e Device name e Description e Product identifier e Version identifier e Serial number Step 1 From the SCE gt prompt type show inventory raw and press Enter Examples for Displaying the SCE Platform Inventory e Displaying the SCE Platform Inventory FRUs Only page 7 12 e Displaying the Complete SCE Platform Inventory page 7 13 Displaying the SCE Platform Inventory FRUs Only The following example shows how to display the inventory UDIs for the FRUs only SCE gt show inventory NAME SCE8000 Chassis DESCR CISCO7604 PID CISCO7604 VID VO SN FOX105108X5 NAME SCE8000 Service Control Module SCM in slot 1 DESCR SCE8000 SCM E PID SCE8000 SCM E VID VO SN CAT1122584N NAME SCE8000 SPA Interface Processor SIP in slot 3 DESCR SCE8000 SIP PID SCE8000 SIP VID VO SN CAT1150GO7F NAME SPA 1X10GE L V2 DESCR SPA 1X10GE L V2 PID SPA 1X10GE L V2 VID V02 SN JAE11517RMR NAME SPA 1X10GE L V2 DESCR SPA 1X10GE L V2 PID SPA 1X10GE L V2 VID V02 SN JAE11496E1P NAME SPA 1X10GE L V2 DESCR SPA 1X10GE L V
82. e User Exec command mode Table 5 1 Parameter show command Initial Setup Configuration configuration command configuration command mode Management IP address and subnet mask show interface GigabitEthernet 1 1 ip address ip address x x x x subnet mask GigabitEthernet Interface Configuration Default gateway show ip default gateway ip default gateway x x x x Global Configuration Hostname show hostname hostname host name Global Configuration Authorization level passwords N A enable password level Zevel encryption type password Global Configuration Clock show clock show calendar calendar set hh mm ss day month year clock read calendar OR clock set hh mm ss day month year clock update calendar Privileged EXEC Time zone show timezone clock timezone zone name offset hours Global Configuration Domain name server show hosts ip domain lookup ip domain name domain name ip name server server address1 server address2 server address3 Global Configuration RDR formatter destination show rdr formatter destination rdr formatter destination ip address port port number Global Configuration OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter5 Connecting the Management Interfaces W Connecting the Management Interface Connecting the Management Interface The SCE
83. e network e XFP 10GER OC192IR component 40km e Optical bypass 10GBE line e XFP 10GZR OC192LR port 80km e 10GBE line port of a e XFP 10G MM SR cascaded SCE8000 platform 200m e EtherChannel port of a CLI designation interface rere st TONIEL TenGigabitEthernet 3 0 0 topology 3 1 0 3 2 0 3 3 0 Refer to Connecting the Line Ports to the Network page 6 1for further information Table 2 7 SPA LEDs LEDs Description Active Link 1 e Green Port is enabled by software and the link is up e Amber Port is enabled by software and the link is down e Unlit Port is not enabled by software Status 2 The Status LED indicates the operational status of the SPA module as follows e Green SPA is ready and operational e Amber SPA power is on and good and SPA is being configured e Off SPA power is off The Cisco SCE8000 Optical Bypass e Optical Bypass Functionality page 2 9 e Optical Bypass Module OPB SCE8K page 2 9 The Cisco SCE8000 platform optical bypass module preserves the service provider 10GBE links under all circumstances At power failure the bypass is automatically activated It can also be activated by the Cisco SCE8000 software The Cisco SCE8000 platform already includes an internal electrical bypass but it is strongly recommended to use the optical bypass module for addressing the following scenarios e During platform reboot SW reload If the external bypass module is not used there i
84. e network element lt gt Port B on the bypass module Cisco SCE8000 port 3 1 0 lt gt Port D on the bypass module CTRL lt gt left hand Optical Bypass port on Cisco SCE8000 SCM E module Dual Link Topology A dual link requires two bypass modules Subscriber side network element lt gt Port A on bypass module 1 Cisco SCE8000 port 3 0 0 lt gt Port C on bypass module 1 Network side network element lt gt Port B on bypass module 1 Cisco SCE8000 port 3 1 0 lt gt Port D on bypass module 1 CTRL on bypass module 1 lt gt left hand Optical Bypass port on Cisco SCE8000 SCM E module Subscriber side network element lt gt Port A on bypass module 2 Cisco SCE8000 port 3 2 0 lt gt Port C on bypass module 2 Network side network element lt gt Port B on bypass module 2 Cisco SCE8000 port 3 3 0 lt gt Port D on bypass module 2 CTRL on bypass module 2 lt gt right hand Optical Bypass port on Cisco SCE8000 SCM E module Cabling the 10GBE Line Interface Ports amp Note A When installing an External Optical Bypass module the Cisco SCE8000 line ports are connected to the module See Cabling the 1OGBE Line Interface Ports Using the External Optical Bypass Module page 6 11 for complete instructions Warning Class 1 laser Avoid exposure to radiation and do not stare into open aperture e Fiber Specifications page 6 10 e Optical Device Maintenance page 6 10 e How to Cable the
85. e rack Connect the cables from the optical bypass module to the line interfaces of the new SCE8000 platform See Optical Bypass Module Connectivity page 6 8 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 a OL 16478 02 FEKc APPENDIX A Using Optical Splitters with 10GBE Links e Supported Configurations page A 1 e Unsupported Configuration page A 2 When designing a deployment with the SCE8000 it is important to keep in mind certain characteristics of the 1OGBE link that affect the configuration of optical splitters and SPAN ports e Ten Gigabit Ethernet does not support autonegotiation unlike regular GBE The fixed OGBE configuration is as follows duplex full speed 10 GBE e The 10GBE port is UP once it detects light and correct sync pattern in the RX input e A Switch or Router port will not transmit data unless it is UP that is it detects a good signal on the RX input Supported Configurations Due to the 1OGBE characterstics described above the following configurations are supported in the 10 GBE environment Figure A 1 Supported Optical Splitter Configuration Subscriber Switch Router Splitter lt a j lr 1 RX TX RX TX CEEE NS 3 NE m 270985 i Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I OL 16478 02 ESN Appendix A Using Optical Splitters with 10GBE Links Figure A 2 Supported SPAN Port Configuration
86. e warnings apply to SPAs and XFP modules that transmit signals via an optical carrier signal Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter9 Removal and Replacement Procedures Removing and Replacing Shared Port Adapters W Figure 9 15 Class 1 Laser Warning Labels for SPA Ports CLASS 1 LASER PRODUCT LASERPRODUKT DER KLASSE 1 PRODUIT LASER DE CLASSE 1 QFA1 LV on PRODUCTO LASER CLASE 1 Warning Class 1 laser product Statement 1008 Warning Invisible laser radiation may be emitted from disconnected fibers or connectors Do not stare into beams or view directly with optical instruments Statement 1051 A Warning Class 1 LED product Statement 1027 Handling SPAs Each SPA circuit board is mounted to a metal carrier and is sensitive to electrostatic discharge ESD damage Always handle the SPA by the carrier edges and handle never touch the SPA components or connector pins SeeFigure 9 16 When a subslot is not in use a SPA blank filler plate must fill the empty subslot to allow the chassis to conform to electromagnetic interference EMI emissions requirements and to allow proper airflow across the installed modules If you plan to install a SPA in a subslot that is not in use you must first remove the SPA blank filler plate Figure 9 16 Handling a SPA Metal carrier a 4 SE Printed circuit board
87. ecause it serves as the main disconnecting device A Warning This product requires short circuit overcurrent protection to be provided as part of the building installation Install only in accordance with national and local wiring regulations Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 aa E OL 16478 02 _ Chapter 4 Installing the Cisco SCE8000 Chassis Preparing for Installation Table 2 5 lists the AC input power cord options specifications and Cisco product numbers for the 2700 W AC input power supplies Table 2 5 also references power cord illustrations Table 4 2 AC Input Power Cord Options Power Cord Reference Locale Part Number Length Plug Rating Illustration North America CAB GSR16 US _ 14 feet 4 3m 250VAC 20A Figure 4 1 locking Europe CAB GSR16 EU 14 feet 4 3m 250VAC 16A Figure 4 1 International CAB AC16A 90L 14 feet 4 3m 250VAC 16A Figure 4 1 IN China CAB ACI16A CH_ 14 feet 4 3 m 250VAC 16A Figure 4 2 Continental CAB AC 2500W 14 feet 4 3 m 250VAC 16A Figure 4 3 Europe EU International CAB AC 2500W I 14 feet 4 3 m 250VAC 16A Figure 4 4 NT Israel CAB AC 2500W I 14 feet 4 3 m 250VAC 16A Figure 4 5 SRL Japan North CAB AC 2500W 14 feet 4 3 m 250VAC 16A Figure 4 6 America US1 nonlocking plug 200 240 VAC operation Japan North CAB AC C6K T 14 feet 4 3 m 250VAC
88. ed Parameters HZ Physical Topologies Type of SCE Platform Redundancy All Active All ports in the EC and all SCE platforms are active If there is a failure in one of the SCE platforms the links on the related ports in the EC will be down and the EC will automatically exclude it from the load distribution The load will then be distributed between the remaining active SCE platforms Since the Cisco SCE8000 supports two links this configuration requires one SCE platform per two links two EC ports N 1 N SCE platforms are active and one platform is on standby The EC ports connected to the standby SCE platform must be configured as standby ports In the case of failure of one of the SCE platforms the EC ports connected to the failing SCE platform are shut and the standby EC ports connected to the standby SCE platform will be activated Since the Cisco SCE8000 supports two links this configuration requires one SCE platform per two links two EC ports plus one extra SCE platform for standby Note that the standby SCE platform must be connected to the two highest numbered ports since EC behavior automatically designates these as the standby ports Redundant Cisco 7600 Series Router Two Cisco 7600 Series routers can be used to provide network redundancy In this topology one link on each Cisco SCE8000 platform is connected to each router Therefore one SCE platform is required for each link Figure 3 8 MGSCP with Re
89. ed instruction set computer RISC processors to exceed beyond packet counting and expand into the contents of network traffic Providing programmable stateful inspection of bidirectional traffic flows and mapping these flows with user ownership SCE platforms provide real time classification of network use The classification provides the basis of the SCE platform advanced traffic control and bandwidth policing functionality Where most bandwidth control functionality ends the SCE platform provides further control and shaping options including e Layer 7 stateful wire speed packet inspection and classification e Robust support for more than 600 protocols and applications including General HTTP HTTPS FTP Telnet Network News Transfer Protocol NNTP Simple Mail Transfer Protocol SMTP Post Office Protocol 3 POP3 Internet Message Access Protocol IMAP Wireless Application Protocol WAP and others Peer to Peer P2P file sharing FastTrack KazaA Gnutella BitTorrent Winny Hotline eDonkey DirectConnect Piolet and others P2P VoIP Skype Skinny DingoTel and others Streaming and Multimedia Real Time Streaming Protocol RTSP Session Initiation Protocol SIP HTTP streaming Real Time Protocol RTP and Real Time Control Protocol RTCP and others e Programmable system core for flexible reporting and bandwidth control e Transparent network and BSS and OSS integration into existing networks e Subscriber
90. el kernel 1 0 0 5 inactive kernel 1 0 0 5 u boot uboot 1 0 0 6 field uboot 0 8 1 13 select ubs cf1 1 0 0 5 secondary ubs cf1 1 0 0 5 Slot 1 SCM 8000 serial num CAT1202G07D part num 73 10598 01 38 cpld 0x8162 vtpld 0xc001 summit 0 0x10008 summit 1 0x10008 dpt tx 0x4837 cls ff f 0x2047 cls flow cap 33554432 cpus 1 cpu SVR 0x80900120 cpu PVR 0x80040202 cpu freq 1000MHz cpu eeprom 2 1 1000MHz cpld Oxalb7 cpld ufm 0xa803 summit 0x10007 cf Model SMART CF FwRev 0x20060811 Size 4062240KB cpu 0 SVR 0x80900121 cpu 0 PVR 0x80040202 cpu 0 freq 1500MHz cpu 1 SVR 0x80900121 cpu 1 PVR 0x80040202 cpu 1 freq 1500MHz cpu 2 SVR 0x80900121 cpu 2 PVR 0x80040202 cpu 2 freq 1500MHz cpu eeprom 2 1 1500MHz cpld 0 Oxb20e cpld 1 Oxb20e cpld 2 Oxb20e cpld 0O ufm 0xb803 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 _ Chapter 9 Removal and Replacement Procedures cpld 1 ufm 0xb803 cpld 2 ufm 0xb803 summit 0 0x1000a summit 1 0x1000a fc 0x1044 CFC 1 board type P2 cpus 3 cpu 0 SVR 0x80900121 cpu 0 PVR 0x80040202 cpu 0 freq 1500MHz cpu 1 SVR 0x80900121 cpu 1 PVR 0x80040202 cpu 1 freq 1500MHz cpu 2 SVR 0x80900121 cpu 2 PVR 0x80040202 cpu 2 freq 1500MHz cpu eeprom 2 1 1500MHz cpld 0 Oxb20e cpld 1 Oxb20e cpld 2 Oxb20e cpld 0O ufm
91. faces in the switch should reside on that VLAN e Connect port 3 3 0 from box A and port 3 2 0 of box B to a switch on a different VLAN Again the access ports should be configured as access ports on this VLAN which will be used only by the interfaces connected to these ports No other interfaces in the switch reside on the VLAN Set topology configurations for each Cisco SCE8000 platform via the connection mode options See How to Configure the Connection Mode page 6 16 Make sure that the Cisco SCE8000 platforms have synchronized and active Cisco SCE8000 platform was selected Use the show interface linecard 0 connection mode command If you want to start with bypass change the link mode to your required mode in both Cisco SCE8000 platforms on both links The bypass mode will be applied only to the active Cisco SCE8000 platform See How to Set the Link Mode page 6 17 Make sure that the link mode is as you required See Monitoring the System page 6 18 Use the show interface linecard 0 link mode command Connect the traffic port of Cisco SCE8000 platform 1 This will cause a momentary down time until the network elements from both sides of the Cisco SCE8000 platform auto negotiate with it and start working when working inline See Dual Link Two Cisco SCE8000s Topology page 6 3 OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter6 Cabling the Line Ports and Completing the Installat
92. flow through the chassis Installing the Optical Bypass Module Step 1 Remove the module filler plate by loosening the two screws Step2 Insert the module into the opening in the panel There are no guide rails Do not touch the module circuitry Step3 Tighten the two captive screws on the module Step4 Connect the cables as described in Cabling the 1OGBE Line Interface Ports Using the External Optical Bypass Module page 6 11 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 a 925 Chapter9 Removal and Replacement Procedures W Removing and Replacing the Optical Bypass Module Replacing the Optical Bypass Module without Disrupting Traffic on the Link Step 1 Step 2 Step 3 Step 4 You can replace a malfunctioning SCE8000 platform without disrupting traffic on the link by removing the optical bypass modules while still connected to the network and installing them into the new SCE8000 Install the new SCE8000 platform in the rack Power up the platform and perform necessary initial configuration Disconnect the cables connecting the optical bypass module to the old SCE8000 platform Do not disconnect the cables connecting the optical bypass to the subscriber side or network side network elements Remove the optical bypass module from the SCE8000 chassis and immediately install it in the new SCE8000 platform Alternatively it can be installed in an external mounting panel elsewhere in th
93. forms in the system Topology related configuration parameters The correct values for each parameter must be ascertained before configuring the system to make sure that the system will function in the desired manner Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 P32 E OL 16478 02 Chapter3 Cisco SCE8000 Topology and Topology Related Parameters Physical Topologies W Physical Topologies Following are descriptions of a number of physical topologies that the Cisco SCE8000 supports e SCE8000 Interface Numbering page 3 3 e Single Cisco SCE8000 Topologies page 3 3 e Dual Cisco SCE8000 Topology Cascade page 3 6 e Multi Gigabit Service Control Platform MGSCP Topology page 3 7 SCE8000 Interface Numbering The following diagram shows the numbering of the SCE8000 interfaces as indicated in the topology diagrams in this chapter The interface numbering is explained as follows e The first digit is the slot number always 3 e The second digit is the number of the sub slot or SPA module 0 3 e The third digit is the number of the interface on the designated SPA module always 0 e Interfaces 3 0 0 and 3 2 0 are on the two left hand SPA modules and are the Subscriber side interfaces e Interfaces 3 1 0 and 3 3 0 are on the two right hand SPA modules and are the Network side interfaces Figure 3 1 SCE8000 Interface Numbering Subscriber 3 0 0 3 1 0 Network Subscriber ENE Network Single Ci
94. g Topology 3 13 Asymmetric Routing and Other Service Control Capabilities 3 13 CHAPTER 4 Installing the Cisco SCE8000 Chassis 4 1 Preparing for Installation 4 2 Safety 4 2 Site Requirements 4 2 Preventing Electrostatic Discharge Damage 4 3 Environmental Requirements 4 3 Power Requirements 4 3 Power Connection Guidelines 4 4 AC Powered Systems 4 4 DC Powered Systems 4 10 Site Planning Checklist 4 11 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Installing the Cisco SCE8000 Chassis in the Rack 4 12 Unpacking the Cisco SCE8000 Chassis 4 12 Installation Guidelines 4 12 Required Tools 4 13 Installing the Chassis Brackets 4 13 Installing the Chassis inthe Rack 4 14 Installing an Optical Bypass Module 4 15 Connecting the System Ground 4 16 Required Tools and Equipment 4 17 Installing the Power Supplies in the Cisco SCE8000 Chassis 4 18 CHAPTER 5 Connecting the Management Interfaces 5 1 How to Set Up the Local Console 5 1 Initial Setup Parameters 5 2 Connecting the Management Interface 5 4 How to Cable the Management Port 5 4 How to Verify Management Interface Connectivity 5 5 CHAPTER 6 Cabling the Line Ports and Completing the Installation 6 1 Connecting the Line Ports to the Network 6 1 Single Link Inline Topology 6 2 Single Link Receive only Topology 6 2 Dual Link Single Cisco SCE8000 Topologies 6 2 Dual Link Two Cisco SCE8000s Topology 6 3 Multi Gigabit Service Control Pl
95. g traffic and not re transmitting it Step1 At the Cisco SCE8000 prompt type show interface TenGigabitEthernet 3 baynumber 0 counters This displays the TenGigabitEthernet counters This command enables you to verify that traffic is taking place You can see that the counters increase together with real time packet flow through the Cisco SCE8000 Remember in bump in the wire topology both the Rx and Tx counters apply as traffic monitors For receive only topologies using an external splitter only the Rx counters apply The following example shows the counters of the first Ten Gigabit Ethernet interface Cisco SCE8000 show interface TenGigabitEthernet 3 0 0 counters In total octets 100 In good unicast packets 90 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 a 613 Chapter6 Cabling the Line Ports and Completing the Installation W How to Load and Activate a Service Control Application In good multicast packets 0 In good broadcast packets 10 In packets discarded 0 In packets with CRC Alignment error 0 In undersized packets 0 In oversized packets 0 Out total octets 93 2 32 1022342538 Out unicast packets 858086051 Out non unicast packets 0 Out packets discarded 0 How to View the User Log Counters Step 1 You should view the user log for errors that occurred during the installation process At the SCE8000 prompt type show logger device User File Log counters and
96. g two links or up to four SCE8000 platforms each cutting a single link Figure 2 8 Optical Bypass Module HS CNTRL 3 el 0153 Ed Je O F STATUS OPB SCE8K MM OPTICAL BYPASS2 242235 Table 2 8 Optical Bypass Module Ports Port Quantity Description Connect This Port To 10 GBE Line 4 10GBE ports A through D SPA interfaces on the Cisco port Duplex LC panel mount adaptor SCE8000 for LC UPC connectors Refer to Cabling the 10GBE Line Interface Ports Using the External Optical Bypass Module page 6 11 for further information CTRL 1 RJ 11 port RJ 11 Optical Bypass port on the SCE8000 SCM E Table 2 9 Optical Bypass Module LEDs LEDs Description Status The Status LED indicates the operational status of the optical bypass module as follows Green Bypass module has been de activated traffic flows through the Cisco SCE8000 platform Off Bypass module is active traffic does not flow through the Cisco SCE8000 platform E Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter 2 Introduction to the Cisco SCE8000 Platform The Cisco SCE8000 Optical Bypass W Optical Bypass Module Specifications Fiber Cable Type The fiber cable type within the Optical Bypass Module area as follows e OPB SCE8K MM 50 um
97. ground Grounding connector System ground connector FAN Status 270892 Step5 Place the grounding wire lug against the grounding pad making sure there is solid metal to metal contact Step6 Secure the grounding lug to the chassis with two M4 screws Ensure that the grounding lug will not interfere with other hardware or rack equipment Step7 Prepare the other end of the grounding wire and connect it to an appropriate grounding point in your site to ensure adequate earth ground for the Cisco SCE8000 chassis Installing the Power Supplies in the Cisco SCE8000 Chassis The SCE8000 chassis is shipped with the power supplies AC or DC already installed Should it be necessary to install a power supply module refer to Removing and Replacing the Power Supply page 9 3 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 Pais D OL 16478 02 Connecting the Management Interfaces This chapter explains how to connect the SCE8000 Service Control Module SCE8000 SCM E to a local console and perform the initial system configuration via the setup wizard that runs automatically Additionally this chapter contains instructions for cabling the Gigabit Ethernet Management interfaces The Console interface CON as well as the Gigabit management interface Port1 are located on the SCE8000 SCM E located in slot 1 of the Cisco SCE8000 chassis see Service Control Module SCE8
98. he Cisco SCE8000 platform to a local console so that you can enter CLI commands for troubleshooting e Troubleshooting firmware package installation boot system lt filename gt Specifies and verifies the package file to be installed Error messages or other output identify problems with the package file Following is a sample output from the boot system command Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 _ Chapter 8 Troubleshooting Troubleshooting Overview W SCE config hoot system ftp cisco cisco 10 10 10 10 downloads SENum pkg pkg Verifying package file SENum pkg pkg Package file verified OK Troubleshooting the management subsystem show interface GigabitEthernet 1 1 Displays IP address and auto negotiation information for the management interfaces Following is a sample output from the show interface GigabitEthernet 1 1 command ip address 10 1 6 145 subnet mask 255 255 0 0 Configured speed auto configured duplex auto AutoNegotiation is On link is Up actual speed 100 actual duplex half show ip default gateway Displays the IP address of the configured default gateway Following is a sample output from the show ip default gateway command Default gateway 10 1 1 1 show ip route Displays the entire routing table and the destination of last resort default gateway Following is a sample output from the show ip route command g
99. he running configuration will be lost You are advised to save the running configuration before performing reload as described in Saving or Changing the Configuration Settings page 7 6 Step 1 At the SCE prompt type reload and press Enter A confirmation message appears Step2 Type y to confirm the reboot request and press Enter Examples for Rebooting the SCE Platform The following example shows the commands for system reboot SCE reload Are you sure y the system is about to reboot this will end your CLI session Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 716 E OL 16478 02 Chapter 7 Basic Cisco SCE8000 Platform Operations Rebooting and Shutting Down the SCE Platform W How to Shut Down the SCE Platform amp Shutting down the SCE platform is required before turning the power off This helps to ensure that non volatile memory devices in the SCE platform are properly flushed in an orderly manner Note Step 1 Step 2 Step 3 When the SCE platform restarts it loads the startup configuration so all changes made in the running configuration will be lost You are advised to save the running configuration before performing reload as described in Saving or Changing the Configuration Settings page 7 6 Connect to the serial console port The CON connector on the front panel of the Service Control module in slot 1 9600 baud The SCE prompt appears Type reload shutdow
100. holder terminal block E Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter9 Removal and Replacement Procedures Step 6 amp Removing and Replacing the Power Supply W 3 Status LEDs 9 Tie wrap 4 DC power cable 10 Cable holder terminal block cover 5 Cable holder cover 11 Tie wrap 6 Ground Attach the appropriate lugs to the DC input wires and ground wire The wires should be sized according to local and national installation requirements Use only copper wire The maximum width of a lug is 0 600 inch 15 2 mm Note Use fine stranded copper conductors rated for 90 degrees Celsius for North American installations Note Step 7 The power supply terminal block lug opening width is 0 62 inch 15 8 mm The terminal posts are centered 0 625 inches 15 88 mm apart and are 1 4 20 threaded We recommend that you use an appropriately sized industry standard 2 hole standard barrel compression lug The power supply ground studs located below the terminal block are also threaded 1 4 20 and require two 1 4 inch split ring washers and two 1 4 20 hex nuts Connect the DC input wires to the 2700 W power supply terminal block Depending on which side you are connecting the DC input wires be sure that the DC input wires rest in the appropriate cable holder The following figure shows DC input wires coming in from the left side Connect the DC input
101. ical Bypass Modules Slots 1 4 top to bottom Required Tools These tools are required to remove or install modules in the Cisco SCE8000 chassis e 3 16 inch flat blade screwdriver e Number 2 Phillips screwdriver e Wrist strap or other grounding device e Antistatic container that the module was shipped in Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter9 Removal and Replacement Procedures Removing and Replacing Modules Hi Handling SIPs Each SIP circuit board is mounted to a metal carrier and is sensitive to electrostatic discharge ESD damage Always handle the SIP by the carrier edges and handle never touch the SIP components or connector pins See Figure 9 9 When a slot is not in use a blank filler plate must be installed in the empty slot to allow the SCE platform to conform to electromagnetic interference EMI emissions requirements and to allow proper airflow across the installed modules If you plan to install a SIP in a slot that is not in use you must first remove the blank filler plate Figure 9 9 Handling a SIP Printed circuit board 70006 Metal carrier GND Installing a Module Step 1 Choose a slot for the module Modules must be installed in the proper slots as follows e A single SCE8000 SCM E module must be installed in slot 1 e Ifa second SCE8000 SCM E module is used it
102. ied Site log established and background information entered Site power voltages verified Site environmental specifications verified Required passwords IP addresses device names and so on needed for initial configuration available refer to Initial Setup Parameters page 5 2 Required tools available Network connection equipment available Cisco SCE8000 mounted in rack System grounding established if required AC DC power cables connected to AC DC sources and Cisco SCE8000 chassis Optical bypass modules installed optional Console port set for 9600 baud 8 data bits no parity and 1 stop bit 9600 8N1 ASCII terminal attached to console port Management port is operational Network interface cables and devices connected System power turned on System boot complete Status LED is on 10 GBE line ports operational Correct hardware configuration displayed after system banner appears Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 a 245 Chapter2 Introduction to the Cisco SCE8000 Platform HZ Cisco SCE8000 Installation Checklist Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 P26 E OL 16478 02 CHAPTER Cisco SCE8000 Topology and Topology Related Parameters This chapter describes the possible deployment topologies of the Cisco SCE8000 and explains how to configure the relevant p
103. iguration file running config Created on 12 06 13 UTC SUN May 11 2008 cli type 1 version 1 no management agent notifications notification list 1417 1418 804 815 1404 1405 1406 1407 1408 400 no management agent notifications notification list 402 421 440 441 444 445 446 450 437 457 no management agent notifications notification list 3593 3594 3595 10040 snmp server community public ro RDR formatter forwarding mode multicast RDR formatter destination 10 56 96 26 port 33000 category number 1 priority 100 RDR formatter destination 10 56 96 26 port 33000 category number 2 priority 100 RDR formatter destination 10 56 96 26 port 33000 category number 3 priority 100 RDR formatter destination 10 56 96 26 port 33000 category number 4 priority 100 interface LineCard 0 connection mode inline on failure external bypass no silent no shutdown attack filter subscriber notification ports 80 replace spare memory code bytes 3145728 interface GigabitEthernet 1 1 ip address 10 56 96 46 255 255 252 0 interface TenGigabitEthernet 3 0 0 bandwidth 10000000 burst size 50000 global controller 0 name Default Global Controller interface TenGigabitEthernet 3 1 0 bandwidth 10000000 burst size 50000 global controller 0 name Default Global Controller interface TenGigabitEthernet 3 2 0 bandwidth 10000000 burst size 50000 global controller 0 name Default Global Controller interface TenGigabitEthernet 3 3 0 bandwidth 10000000 burst size 50000 g
104. iguration from any management interface all configuration settings are saved regardless of the management interface used to set the configuration For backup purposes the old startup config file is saved under the directory system prevconf Refer to Restoring a Previous Configuration page 7 8 for an explanation on how to restore a previous configuration To remove a configuration command from the running config use the no form of the command Step 1 At the SCE prompt type show running config to view the running configuration The running configuration is displayed Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter 7 Basic Cisco SCE8000 Platform Operations Step 2 Step 3 Managing Cisco SCE8000 Configurations W Check the displayed configuration to make sure that it is set the way you want If not make the changes you want before saving Type copy running config startup config The system saves all running configuration information to the configuration file which is used when the system reboots The configuration file holds all information that is different from the system default in a file called config tx located in the directory system Example for Saving or Changing the Configuration Settings The following example shows how to save the running configuration file first displaying the file to review the settings SCE show running config This is a general conf
105. igured as standby ports on both ECs Therefore for N 1 redundancy one router and five Cisco SCE8000 platforms would be used to support eight links If two Cisco 7600 Series routers are used for network redundancy one link on each Cisco SCE8000 platform is connected to each router This requires twice the number of Cisco SCE8000 platforms one platform for each link A minimum of eight Cisco SCE8000 platforms are required to support eight ports For N 1 redundancy nine Cisco SCE8000 platforms would be used to support eight active links When cabling to the EC follow these guidelines The Cisco SCE platform ports MUST be connected to the EC ports in the same order on both sides The EC ports should be sorted in an ascending order by their physical interface numbers In a topology with two Cisco 7600 Series routers the order of connection to the EC ports must be the same on both routers In order for both routers to send the traffic of a given subscriber to the same SCE platform the SCE platforms must be connected to both routers in exactly the same order one SCE platform connected to the first link on both routers another SCE platform connected to the second link on both routers and so on Refer to MGSCP Connectivity Examples page 6 4 for specific examples explaining how to connect the Cisco SCE8000 ports to the EC ports in various topologies Refer to Dual Link Single Cisco SCE8000 Topologies page 6 2 and Single Link Inl
106. ike the SCE platform just to forward the traffic Note that this is only relevant to inline topologies even though the configuration is available also when in receive only mode The following link mode options are available e Forwarding forwards traffic on the specified link to the SCE platform for processing e Bypass stops all forwarding of traffic on the specified link to the SCE platform Traffic still flows on the link but is not processed in any way by the SCE platform This does not affect the redundancy states e Cutoff completely cuts off flow of traffic through the specified link Note the following recommendations and restrictions OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter6 Cabling the Line Ports and Completing the Installation W Cascaded Systems e Link mode is relevant only to inline topologies e Itis recommended that in cascaded topologies both SCE platforms be configured for the same link mode otherwise the service will be unpredictable e The default link mode is forwarding When other link modes are selected active service control is not available and any service control configuration will not be applicable Step1 From the Cisco SCE8000 config if prompt type link mode forwarding lbypasslcutoff and press Enter Monitoring the System Use the following commands to view the current connection mode and link mode parameters e How to View
107. ine Topology page 6 2 for further information on specific cabling schemes MGSCP Connectivity Examples The First Step Ordering the EC Ports page 6 5 Single Router MGSCP Connectivity page 6 5 Single Router with N 1 Redundancy MGSCP Connectivity page 6 5 Dual Routers MGSCP Connectivity page 6 6 Dual Routers with N 1 Redundancy MGSCP Connectivity page 6 7 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 lt OL 16478 02 _ Chapter 6 Cabling the Line Ports and Completing the Installation Connecting the Line Ports to the Network Mil The First Step Ordering the EC Ports This section explains how to order the EC ports and assign them to links This example is the basis for all following examples 1 Sort the EC ports in an ascending order by their physical interface numbers Take the following EC interfaces as an example ECI subscriber side 0 1 0 2 1 3 1 5 EC2 network side 2 2 3 1 3 2 3 4 2 Order the ports in subscriber network pairs according to their order in the ECs the first port in EC1 subscriber side is paired with the first port in EC2 network side and so on Link 1 S 0 1 N 2 2 Link 2 S 0 2 N 3 1 Link 3 S 1 3 N 3 2 Link 4 S 1 5 N 3 4 Single Router MGSCP Connectivity Four links would require two Cisco SCE8000 platforms Connect the ordered pairs each pair of EC ports to a pair of Subscriber Network ports in a Cisco SCE8000 platform e Cisco SCE800
108. info messages 1 Total warning messages 0 Total error messages 0 Total fatal messages 0 If there are Total error messages or Total fatal messages use the show logger device user file log command to display details about the errors OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter7 Basic Cisco SCE8000 Platform Operations HZ Starting the Cisco SCE8000 Platform Viewing the Ten Gigabit Ethernet Port Status Step 1 At the Cisco SCE8000 prompt type show interface TenGigabitEthernet 3 baynumber 0 This displays the port link status The following example displays a system response Cisco SCE8000 show interface TenGigabitEthernet 3 1 0 Actual Status Link is on Bandwidth 10000000Kbps Burst size 500000bytes Viewing the Ten Gigabit Ethernet Counters Step 1 In an inline topology you can monitor traffic via the platform counters for both the Rx and Tx connections The counters increase as packets flow through the Cisco SCE8000 for both Rx and Tx However in receive only topologies the counters for the Tx do not increment as the SCE8000 is only monitoring traffic and not re transmitting it At the Cisco SCE8000 prompt type show interface TenGigabitEthernet 3 baynumber 0 counters This displays the TenGigabitEthernet counters This command enables you to verify that there is traffic on the line You can see that the counters increase together with
109. installed Dual link connectivity e Port 3 0 0 Link 0 Subscribers side e Port 3 1 0 Link 0 Network side e Port 3 2 0 Link 1 Subscribers side e Port 3 3 0 Link 1 Network side Note Receive only topologies can be implemented using either an optical splitter or a switch If a switch is used it must support SPAN functionality that includes separation between ingress and egress traffic and multiple SPAN ports destinations Dual Link Two Cisco SCE8000s Topology amp In this topology two Cisco SCE8000s are connected to two full duplex 10GBE links providing full redundancy through cascading the two Cisco SCE8000s The Cisco SCE8000s must be inline Note When installing a cascaded system it is extremely important to follow the sequence of procedures outlined in Cascaded Systems page 6 15 When two Cisco SCE8000s are used the ports 3 0 0 and 3 1 0 in each Cisco SCE8000 are connected to the links while ports 3 2 0 and 3 3 0 are the cascade ports that are used for communicating between the two Cisco SCE8000s as follows Cisco SCE8000 1 e Port 3 0 0 Link 0 Subscribers side e Port 3 1 0 Link 0 Network side e Port 3 2 0 Cascade connect to Port 3 3 0 in Cisco SCE8000 2 e Port 3 3 0 Cascade connect to Port 3 2 0 in Cisco SCE8000 2 Cisco SCE8000 2 e Port 3 0 0 Link 1 Subscribers side e Port 3 1 0 Link 1 Network side e Port 3 2 0 Cascade connect to Port 3 3 0 in Cisco SCE8000 1 e Port 3 3 0 Cascade
110. ion MI Cascaded Systems Step9 Connect the traffic port of Cisco SCE8000 platform 2 This will cause a momentary down time until the network elements from both sides of the Cisco SCE8000 platform auto negotiate with it and start working when working inline See Dual Link Two Cisco SCE8000s Topology page 6 3 Step 10 When full control is needed change the link mode on both Cisco SCE8000 platforms on both links to forwarding It is recommended to first configure the active Cisco SCE8000 platform and then the standby See How to Set the Link Mode page 6 17 Step 11 You can now start working with the Subscriber Manager CLI Commands for Cascaded Systems This section presents CLI commands relevant to the configuration and monitoring of a redundant system Use the following commands to configure and monitor a redundant system e connection mode e no force failure condition e show interface linecard 0 connection mode e show interface linecard 0 physically connected links e Topology Related Parameters for Redundant Topologies page 6 16 e How to Configure the Connection Mode page 6 16 e How to Set the Link Mode page 6 17 e Monitoring the System page 6 18 Topology Related Parameters for Redundant Topologies All four of the topology related parameters are required when configuring a redundant topology e Connection mode Redundancy is achieved by cascading two SCE platforms Therefore the connection mode fo
111. ither power supply On a slave SCE8000 SMC_E module in the second slot this LED is always off Status The Status LED indicates the operational status of the Cisco SCE8000 system as follows e Unlit No power from either power unit e Steady amber The system is booting up e Flashing amber The system is operational but is in a warning state e Flashing green The system is fully operational e Steady red There is a problem or failure Note that Alarms are hierarchical Failure takes precedence over Warning which takes precedence over Operational Optical Bypass e Steady amber The optic bypass module has been directed to pass traffic via the Cisco SCE8000 e Unlit The optic bypass module if present will connect the link fibers directly and traffic will bypass the Cisco SCE8000 On a slave SCE8000 SMC_E module in the second slot this LED is always off Note that this functionality is consistent even when the Cisco SCE8000 is powered down Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 a 23 Chapter2 Introduction to the Cisco SCE8000 Platform HZ Introduction to SIPs and SPAs Table 2 3 SCE8000 SCM E LEDs LEDs Description Master Indicates the master Service Control module e Steady green Master Service Control module e Unlit Slave Service Control module Mng interface The Mng interface LEDs indicate the operational status of th
112. ity If so there must be a backup Cisco SCE8000 platform or a backup for each platform in an MGSCP topology to assume operation in case of failure of the primary device A backup SCE platform is connected in a cascade configuration with the primary SCE platform so that although all processing is performed only in the active Cisco SCE8000 the standby Cisco SCE8000 is constantly updated with all the necessary information so that it can instantly take over processing the traffic on the data links should the active Cisco SCE8000 fail Note that an MGSCP topology with multiple Cisco SCE8000 platforms provides more sophisticated redundancy options but the basic decision on each link is the same does it require a standby SCE platform or not Link continuity How should the Cisco SCE8000 respond to platform failure with regard to link continuity Should traffic flow continue even though the unit is not operating or be halted until the platform is repaired replaced If link continuity is a high priority an external optical bypass module can be installed on the link See Link Continuity page 3 9 and The Cisco SCE8000 Optical Bypass page 2 8 Note In cascade configuration installation of an external optical bypass module is required These issues determine two important aspects of system deployment and configuration Physical topology of the system The actual physical placement and connection of the Cisco SCE8000 platform or plat
113. ity primary lsecondary on failure external bypass bypass cutoff and press Enter EXAMPLE 1 Use the following command to configure the primary SCE platform in a two SCE platform inline topology Link 1 is connected to this SCE platform and the behavior of the SCE platform if a failure occurs is bypass Cisco SCE8000 config if connection mode inline cascade physically connected links link 1 priority primary on failure bypass EXAMPLE 2 Use the following command to configure the SCE platform that might be cascaded with the SCE platform in Example 1 This SCE platform would have to be the secondary SCE platform and Link 0 would be connected to this SCE platform since Link 1 was connected to the primary The connection mode would be the same as the first and the behavior of the SCE platform if a failure occurs is also bypass Cisco SCE8000 config if connection mode inline cascade physically connected links link 0 priority secondary on failure bypass How to Set the Link Mode The SCE platform has an internal hardware card used to maintain the links even when the SCE platform fails This hardware card has three possible modes of operation e bypass e forwarding e cutoff Normally the link mode is selected by the SCE platform software according to the configured connection mode However the link mode command can be used to enforce a specific desired mode This may be useful when debugging the network or in cases where we would l
114. k install activation operation Install management agent property com pcube management framework install activated package SCA BB management agent property com pcube management framework install activated version 316 buald 79 management agent property com pcube management framework install activation date Sun May 11 08 44 04 GMT 00 00 2008 flow filter partition name ignore_filter first rule 4 num rules 32 flow filter partition name udpPortsToOpenBySw first rule 40 num rules 21 SCE copy system config tx1l system config txt How to Display the SCE Platform Version Information Use this command to display global static information on the SCE platform such as software and hardware version image build time system uptime last open packages names and information on the SLI application assigned Step 1 From the SCE gt prompt type show version and press Enter Example for Displaying the SCE Platform Version Information The following example shows how to display the SCE platform version information Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 on Chapter 7 Basic Cisco SCE8000 Platform Operations W How to Display the SCE Platform Version Information SCE gt show version System version Version 3 1 6S Build 279 Build time Jun 10 2008 19 27 47 Change list 335658 Software version is Version 3 1 6S Build 279 Hardware information is kernel kernel 1 0 0 5 in
115. le Solution CLI command show ip route lt host ip address gt Routing tables are incorrectly configured when the host used as client is not in the same network as the SCE Platform and there is more than one gateway on the SCE Platform network Check reconfigure routing tables See Initial Setup Parameters page 5 2 Refer to IP Configuration in the Cisco SCE8000 Software Configuration Guide CLI commands e show access lists e show ip access class Host is not a member of a valid access list See Initial Setup Parameters page 5 2 Refer to Access Control Lists in the Cisco SCE8000 Software Configuration Guide Telnet connection terminates automatically CLI commands e show line e show line vty timeout Telnet connection may be timing out Reconfigure line timeout timeout lt time in seconds gt Troubleshooting the Link Interface Subsystem Check the following to help isolate a problem in the link interface subsystem In general the case where no traffic is coming out of the Cisco SCE8000 is often caused by link problems or the 1OGBE interface configuration Note that in some cases the problem which seems as a transmit problem could be in the Rx no traffic is being received by the Cisco SCE8000 or there is actually no traffic on the line which could be a normal situation amp Note SCE8000 SIP subslot This can be 0 through 3 In CLI commands for
116. list and that all the specified interfaces are included Installation Guidelines Before installing the chassis ensure that the equipment rack complies with the following guidelines e The width of the rack measured between the two front mounting strips or rails must be 17 75 inches 45 09 cm e The depth of the rack measured between the front and rear mounting strips must be at least 19 25 inches 48 9 cm but not more than 32 inches 81 3 cm e The rack must have sufficient vertical clearance to insert the chassis The height of the Cisco SCE8000 chassis is 8 7 inches 22 09 cm 5 RU If the rack is on wheels ensure that the brakes are engaged or that the rack is otherwise stabilized Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 a12 i OL 16478 02 Chapter4 Installing the Cisco SCE8000 Chassis Installing the Cisco SCE8000 Chassis inthe Rack W amp Note We recommend that you maintain a minimum air space of 6 inches 15 cm between walls and the chassis air vents and a minimum horizontal separation of 12 inches 30 5 cm between two chassis to prevent overheating The installation hardware is not suitable for use with racks with obstructions such as a power strip that could impair access to field replaceable units FRUs A Warning To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The fo
117. llowing guidelines are provided to ensure your safety gt This unit should be mounted at the bottom of the rack if it is the only unit in the rack gt When mounting this unit in a partially filled rack load the rack from the bottom to the top with the heaviest component at the bottom of the rack gt If the rack is provided with stabilizing devices install the stabilizers before mounting or servicing the unit in the rack Required Tools These tools and equipment are required to install the chassis in the rack e Number 1 and number 2 Phillips head screwdrivers e 3 16 inch flat blade screwdriver e Tape measure and level e Masking tape or some other method of marking the desired installation height in the rack Installing the Chassis Brackets The chassis is shipped with the mounting brackets installed on the front of the chassis These brackets can be installed on the rear of the chassis To install the brackets on the rear of the chassis perform these steps Step 1 Remove the screws that secure the brackets to the chassis Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 EEN Chapter 4 Installing the Cisco SCE8000 Chassis HZ installing the Cisco SCE8000 Chassis in the Rack Step 2 Step 3 Step 4 Installing the A Figure 4 13 Brackets on Cisco SCE8000 Chassis ae AN STATUS 270890 Position one of the brackets against
118. lobal controller 0 name Default Global Controller exit ip default gateway 10 56 96 1 line vty 0 4 exit management agent property com pcube management framework install activation operation Install management agent property com pcube management framework install activated package SCA BB OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter7 Basic Cisco SCE8000 Platform Operations W Managing Cisco SCE8000 Configurations management agent property com pcube management framework install activated version 30 6 buird 79 management agent property com pcube management framework install activation date Sun May 11 08 44 04 GMT 00 00 2008 flow filter partition name ignore_filter first rule 4 num rules 32 flow filter partition name udpPortsToOpenBySw first rule 40 num rules 21 SCE copy running config startup config writing general configuration file to temporary location Backing up general configuration file Copy temporary file to final location SCE Tip To remove a configuration command from the running config use the no form of the command The following example illustrates how to remove all DNS settings from the running configuration SCE config no ip name server Restoring a Previous Configuration When you save a new configuration the system automatically backs up the old configuration in the directory system p
119. lt gt Nonprinting characters such as passwords are in angle brackets Default responses to system prompts are in square brackets I An exclamation point or a pound sign at the beginning of a line of code indicates a comment line OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E About this Guide amp Note P Means reader take note Tip A Means the following information will help you solve a problem Caution Means reader be careful In this situation you might perform an action that could result in equipment damage or loss of data Timesaver A Means the described action saves time You can save time by performing the action described in the paragraph Warning Means reader be warned in this situation you might perform an action that could result in bodily injury Obtaining Documentation and Submitting a Service Request For information on obtaining documentation submitting a service request and gathering additional information see the monthly What s New in Cisco Product Documentation which also lists all new and revised Cisco technical documentation at http www cisco com en US docs general whatsnew whatsnew html Subscribe to the What s New in Cisco Product Documentation as a Really Simple Syndication RSS feed and set content to be delivered directly to your desktop using a reader applic
120. ly with existing network elements and business support systems BSS and operational support systems OSS Cisco Service Control Capabilities The core of the Cisco service control solution is the network hardware device the Service control engine SCE The core capabilities of the SCE platform which support a wide range of applications for delivering service control solutions include e Subscriber and application awareness Application level drilling into IP traffic for real time understanding and controlling of usage and content at the granularity of a specific subscriber Subscriber awareness The ability to map between IP flows and a specific subscriber to maintain the state of each subscriber transmitting traffic through the SCE platform and to enforce the appropriate policy on this subscriber s traffic Subscriber awareness is achieved either through dedicated integrations with subscriber management repositories such as a DHCP or a RADIUS server or through sniffing of RADIUS or DHCP traffic Application awareness The ability to understand and analyze traffic up to the application protocol layer Layer 7 For application protocols implemented using bundled flows such as FTP which is implemented using Control and Data flows the SCE platform understands the bundling connection between the flows and treats them accordingly e Application layer stateful real time traffic control The ability to perform advanced cont
121. mmunications equipment and installation procedures Document Revision History Cisco Service Control Revision Release and Date Change Summary OL 16478 02 3 1 7 Added explanation of casacade topology and cabling December 2008 OL 16478 01 3 1 6S First version New document for new product June 2008 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 ca About this Guide Organization The major sections of this guide are as follows Chapter Title Description 1 Cisco Service Control Overview page 1 1 This chapter provides a brief introduction to Cisco Service Control Introduction to the Cisco SCE8000 Platform page 2 1 This chapter provides a hardware overview of the SCE8000 platform Cisco SCE8000 Topology and Topology Related Parameters page 3 1 This chapter describes the possible deployment topologies of the SCE8000 and explains how various aspects of the topology determine the configuration of the system Installing the Cisco SCE8000 Chassis page 4 1 This chapter explains how to install a SCE8000 platform in the rack and properly ground it Connecting the Management Interfaces page 5 1 This chapter explains how to connect the SCE8000 platform to a local console and perform the initial system configuration via the setup wizard that runs automatically Cabling the Line Ports and Completing the Installation page 6 1 This
122. n A confirmation message appears Type y to confirm the shutdown request and press Enter Examples for Shutting Down the SCE Platform The following example shows the commands for system shutdown SCE reload shutdown You are about to shut down the system The only way to resume system operation after this is to cycle the power off and then back on Continue kd IT IS NOW SAFE TO TURN THE POWER OFF Note Since the SCE platform can recover from the power down state only by being physically turned off or cycling the power this command can only be executed from the serial CLI console This limitation helps prevent situations in which a user issues this command from a Telnet session and then realizes he or she has no physical access to the SCE platform OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter7 Basic Cisco SCE8000 Platform Operations HZ Rebooting and Shutting Down the SCE Platform Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 P78 i OL 16478 02 CHAPTER Troubleshooting Your Cisco SCE8000 platform went through extensive testing before leaving the factory However if you encounter problems starting it use the information in this chapter to help isolate the cause of the problems The procedures in this chapter assume that you are troubleshooting the initial system startup and that your Cisco SCE8000 platform is in the original fa
123. n Guide Rel 3 1 7 e12 E OL 16478 02 Chapter6 Cabling the Line Ports and Completing the Installation Cabling the 10GBE Line Interface Ports W Testing Connectivity Examining Link LEDs and Counters If the Cisco SCE8000 platform has been powered up test now to verify that connectivity has been established on all links If the Cisco SCE8000 platform is not powered up perform this step after starting the Cisco SCE8000 platform e Examining the LEDs page 6 13 e How to View the Ten Gigabit Ethernet Port Status page 6 13 e How to View the Ten Gigabit Ethernet Counters page 6 13 e How to View the User Log Counters page 6 14 Examining the LEDs The LOGBE Link LED should be green verifying that an active connection exists How to View the Ten Gigabit Ethernet Port Status Step1 At the Cisco SCE8000 prompt type show interface TenGigabitEthernet 3 baynumber 0 This displays the port link status The following example displays a system response Cisco SCE8000 show interface TenGigabitEthernet 3 1 0 Actual Status Link is on Bandwidth 10000000Kbps Burst size 500000bytes How to View the Ten Gigabit Ethernet Counters In an inline topology you can monitor traffic via the platform counters for both the Rx and Tx connections The counters increase as packets flow through the Cisco SCE8000 for both Rx and Tx However in receive only topologies the counters for the Tx do not increment as the SCE8000 is only monitorin
124. n the bottom slot of the chassis e Hot swappable fan assembly redundant AC input or DC input power supplies Removing and Replacing the Power Supply amp This section describes how to remove and install power supplies for the Cisco SCE8000 Note In systems with redundant power supplies you can replace the faulty supply while the system is operating e Required Tools page 9 3 e Removing an AC Input Power Supply page 9 3 e Installing an AC Input Power Supply page 9 5 e Removing a DC Input Power Supply page 9 5 e Installing a DC Input Power Supply page 9 7 Required Tools A flat blade or number 2 Phillips head screwdriver is required to perform these procedures Additionally a wire cutter or scissors may be necessary for cutting cable tie wraps Removing an AC Input Power Supply A Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing Step 1 Turn the power switch to the Off 0 position on the power supply you are removing Step2 Disconnect the power cord from the power source Do not touch the metal prongs on the power cord when it is still connected to the power supply Step3 Remove the power cord from the power connection on the power supply module Do not touch the metal prongs embedded in the power supply Step4 Loosen the captive installation screws on the power supply Cisco SCE8000 Installation and Configuration Guide Rel 3 1
125. nd some of the flows may be split i e the upstream packets of the flow go on one link and the downstream packets go on the other link When installed in this topology the Cisco SCE8000 completely overcomes this phenomenon and provides its normal monitoring functionality as if asymmetrical routing were not occurring in the two links This installation supports monitoring functionality only and is configured as receive only connection mode OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter3 Cisco SCE8000 Topology and Topology Related Parameters W Physical Topologies Figure 3 5 Dual Link Receive Only Topology Subscriber 1 ol Splitter Network 1 sa E 3 0 0 mmm 3 1 0 TDN 3 3 0 m EO Network 2 Splitter 270587 l Subscriber 2 amp Note When implementing receive only topologies with a switch the switch must support SPAN functionality that includes separation between ingress and egress traffic and multiple SPAN ports destinations Dual Cisco SCE8000 Topology Cascade In this topology two cascaded Cisco SCE8000s are used This allows a fail over solution where in case of a failure of one Cisco SCE8000 the functionality that the Cisco SCE8000 provides is preserved by the redundant platform This topology allows both control and monitoring functionality where redundancy is required and inline connection is used
126. network redundancy protocols like HSRP are responsible for identifying the line cutoff and switching all the traffic to go through the functioning Cisco SCE8000 In addition it is possible to configure the Cisco SCE8000 to use the external optical bypass device so that in the event of any failure of the Cisco SCE8000 it will be used to provide link continuity This ensures 100 link continuity at the expense of providing asymmetric routing functionality Multi Gigabit Service Control Platform MGSCP Topology In this topology multiple Cisco SCE8000 platforms are connected to a Cisco 7600 Series router which acts as a dispatcher between the platforms The router contains two EtherChannels ECs one for the subscriber side and one for the network side that perform load balancing for the SCE platform traffic Traffic enters the first router is distributed between the SCE platforms by the subscriber side EC and then returns to the router so it can be forwarded to its original destination Figure 3 7 Basic MGSCP Topology 4 Subscribers f 40Gig Cisco 7600 so amp SCE8000s There are a number of variables to be considered in the MGSCP topology Two of the main factors to be considered include Type of SCE Platform Redundancy page 3 8 Redundant Cisco 7600 Series Router page 3 8 OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter3 Cisco SCE8000 Topology and Topology Relat
127. ng and replacing the l port 10GBE SPAs please follow these guidelines e SPAs must be installed in pairs The Cisco SCE8000 supports the following SPA configurations Two SPAs inserted in subslots 0 and 1 Four SPAs e If only two SPAs are installed sublots 2 and 3 must be covered by blank filler panels e Required Tools and Equipment page 9 22 e Laser LED Safety page 9 22 e Handling SPAs page 9 23 e SPA Installation and Removal page 9 23 e Installing a SPA in a SIP page 9 24 e Removing a SPA from a SIP page 9 24 Required Tools and Equipment You need the following tools and parts to install SPAs If you need additional equipment contact a service representative for ordering information e Shared port adapter SPA e Number 1 Phillips and a 3 16 inch flat blade screwdriver e Number 2 Phillips screwdriver e Your own electrostatic discharge ESD prevention equipment or the disposable grounding wrist strap supplied with the SPA e Antistatic container that the SPA was shipped in Laser LED Safety An optical single mode transmitter uses a small laser to transmit the light signal to the network ring Keep the transmit port covered whenever a cable is not connected to it Although multi mode transceivers typically use LEDs for transmission it is good practice to keep open ports covered and avoid staring into open ports or apertures The transceivers aperture port contains a laser warning label as shown in Figure 9 15 Thes
128. ng kit 69 0815 01 e Grounding lug e Two M4 hex head screws with locking washers Optical Bypass module kit e Optical Bypass Module e Control Cable 2 m e Control Cable 40 cm wy Note Cisco does not ship the entire Cisco SCE8000 documentation set automatically with each system You must specifically order the documentation as part of the sales order If you ordered documentation and did not receive it we will ship the documents to you within 24 hours To order documents contact a customer service representative Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter 2 Introduction to the Cisco SCE8000 Platform Cisco SCE8000 Installation Checklist W Cisco SCE8000 Installation Checklist To assist you with your installation and to provide a historical record of what was done by whom photocopy the following Cisco SCE8000 Installation Checklist Indicate when each procedure or verification is completed When the checklist is completed place it in your site log along with the other records for your new Cisco SCE8000 platform Table 2 11 Cisco SCE8000 Installation Checklist Task Verified By Date Date Cisco SCE8000 received Cisco SCE8000 and all accessories unpacked Safety recommendations and guidelines reviewed Topology verified number of Cisco SCE8000 platforms number of links and whether inline or receive only Installation Checklist cop
129. ng the Installation Connecting the Line Ports to the Network Mil e Router 2 N 3 1 Cisco SCE8000 2 3 3 0 e Router 1 S 1 3 Cisco SCE8000 3 3 0 0 e Router 2 S 1 3 Cisco SCE8000 3 3 2 0 e Router 1 N 3 2 Cisco SCE8000 3 3 1 0 e Router 2 N 3 2 Cisco SCE8000 3 3 3 0 e Router 1 S 1 5 Cisco SCE8000 4 3 0 0 e Router 1 S 1 5 Cisco SCE8000 4 3 2 0 e Router 1 N 3 4 Cisco SCE8000 4 3 1 0 e Router 1 N 3 4 Cisco SCE8000 4 3 3 0 Dual Routers with N 1 Redundancy MGSCP Connectivity In order to have N 1 redundancy we must add one extra SCE platform as the standby platform We also must add another port on each EC to be used as standby ports In this case we would use five SCE platforms four on the traffic links and one for redundancy which would be connected to the standby ports Again for the sake of simplicity we assume that the EC ports are the same on both routers If we added ports 0 3 on EC1 and 2 4 on EC2 the ECs would look like this e EC1 0 1 0 2 0 3 1 3 1 5 e EC2 2 2 2 4 3 1 3 2 3 4 The standby ports must be the highest numbered ports e ECI standby port 1 5 e EC2 standby port 3 4 The traffic ports would be assigned to the links as follows e Link 1 S 0 1 N 2 2 e Link 2 S 0 2 N 2 4 e Link 3 S 0 3 N 3 1 e Link 4 S 1 3 N 3 2 The standby ports would be assigned to the links as follows e Link 5 standby S 1 5 N 3 4 If Cisco SCE8000 5 is the redundant platform Link 5 from both routers wo
130. o SCE8000 Flatten the shipping cartons and store them with the pallet You will need these containers if you need to move or ship the Cisco SCE8000 in the future Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 a 243 Chapter2 Introduction to the Cisco SCE8000 Platform Checking the Shipping Container Contents Cisco SCE8000 Component List Table 2 10 Component Cisco SCE8000 Component List Description Cisco SCE8000 platform Cisco SCE8000 10GBE chassis configured with the following components Cisco SCE8000 SCM E Cisco SCE8000 Service Control Module Cisco SCE8000 SIP Cisco SCE8000 SPA Jacket card Interface Processor 2 or 4 SPA Jacket cards SPA Interface See below the list of supported SPA models 2 or 4 XFP OpticsXFP optic modules See below the list of supported XFP models 2 Cisco PWR 2700 AC 4 or 2 Cisco PWR 2700 DC 4 Cisco power supply units AC or DC Hot swappable redundant power supply compatible with Cisco 7604 router SCE8000 FAN Redundant fans unit Accessories The following accessories might arrive in separate shipping containers Management cables e Gigabit Ethernet cable for connecting to the Management ports e RS 232 serial cables DB 9 to RJ 45 and DB 25 to RJ 45 for connecting to a local terminal Power cables Two AC power supply cords if ordered with AC input power supply units Groundi
131. o SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 49 Chapter4 Installing the Cisco SCE8000 Chassis Preparing for Installation Figure 4 12 CAB C19 CBN i fl Connector Cordset rating 16 A 250 V Connector IEC 60320 C20 Length 9 ft 0 in 2 7 m IEC 60320 C19 DC Powered Systems Basic guidelines for DC powered systems include the following e Each chassis power supply should have its own dedicated input power source The source must comply with the safety extra low voltage SELV requirements in the UL 60950 CSA 60950 EN 60950 IEC 60950 standards e The DC supplies each have the provision for a dual connection to the power source in order to permit high power operation without exceeding current ratings For the SCE8000 it is not necessary to connect both of these inputs to DC power sources it is sufficient to connect only the 1 connections e Each circuit must be protected by a dedicated two pole circuit breaker The circuit breaker should be sized according to the power supply input rating and local or national code requirements e The circuit breaker is considered the disconnect device and should be easily accessible e The system ground is the power supply and chassis ground A Caution Do not connect the DC return wire to the system frame or to the system grounding e
132. o disconnect the plug from the socket press down on the raised portion on top of the plug releasing the latch You should hear an audible click indicating the latch has released Carefully pull the plug out of the socket If the Link LED still does not light verify that the cable is connected correctly to the appropriate network element on its second end How to Verify Management Interface Connectivity Step 1 Step 2 amp If the Cisco SCE8000 platform has been powered up test now to verify that connectivity has been established between the Cisco SCE8000 and the remote management host If the Cisco SCE8000 platform is not powered up perform this step after starting the Cisco SCE8000 platform After you connect the cable to the GBE management port and to your network check the relevant Mng port LEDS There are two GBE LEDs Link Active and 10 100 1000 refer to Service Control Module SCE8000 SCM E page 2 2 At this point check that the Link Active LED is green The state of the 10 100 1000 LED will depend on the Ethernet network settings as follows e Off 10 Mbps e Green 100 Mbps e Orange 1000 Mbps Test connectivity From the host that you intend to use for remote management ping to the Cisco SCE8000 by typing ping and the Cisco SCE8000 IP address and pressing Enter see the example below Note Note that only this step Step 2 is performed from the remote management host connected by LAN to the Mng
133. ooting Overview L2 In total octets 792000 In good unicast packets 12000 In good multicast packets 0 In good broadcast packets 0 In packets discarded 0 In packets with CRC Alignment error 0 In undersized packets 0 In oversized packets 0 Rx pause packets 0 L2 Out total octets 0 Out unicast packets 0 Out good multicast packets 0 Out good broadcast packets 0 Out packets discarded 0 Tx pause packets 0 Tx regular collision events 0 L2 Bandwidth Kbps Rx Tx 0 of packets received of length in octets 64 0 65 127 12000 128 255 0 256 511 0 512 1023 0 1024 1518 0 1519 0 Refer to Troubleshooting with the User Log page 8 11 for an explanation of commands related to the user log Checking the LEDs The LEDS on the SCE8000 SMC E front panel along with the LEDs on the power supplies and fan assembly are the most immediate problem detection mechanism of the platform Refer to the following sections for information on Cisco SCE8000 platform LEDS e Table 2 3 on page 2 3 e Examining the LEDs page 6 13 e Starting the System and Observing Initial Conditions page 7 2 e Cisco SCE8000 Operational Status page 8 5 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 lt OL 16478 02 Chapter8 Troubleshooting Cisco SCE8000 Operational Status The following table lists the operational states of the Cisco SCE8000 The Status LED on the Service Control module reflects the c
134. or cable connection When you start up the Cisco SCE8000 platform for the first time you should observe the startup sequence described in Starting the Cisco SCE8000 Platform page 7 1 This section contains a more detailed description of the normal startup sequence and describes the steps to take if the system does not perform that sequence as expected LEDs indicate all system states in the startup sequence By checking the state of the LEDs you can determine when and where the system failed in the startup sequence Use the following descriptions to isolate the problem to a subsystem and then proceed to the appropriate sections to try to resolve the problem When you start up the system by turning on the power supply switch the following should occur e You should immediately hear the fans operating Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter8 Troubleshooting Troubleshooting Overview W e Ifthe Status LED is flashing orange indicating a warning state check the user log At the prompt type more user log If any of the following warning messages appear and the root cause is not obvious and easily solved such as obstruction of external air flow turn the Cisco SCE8000 platform off and call technical support voltage problem fans problem abnormal raise in interior temperature Troubleshooting the Power Subsystem Check the following to help isolate a problem in
135. or on the 1 Port 10 Gigabit Ethernet SPA is a fiber optic receiver that supports one XFP The types of optics modules that have been qualified for use with the 1 Port 10 Gigabit Ethernet SPA on the Cisco SCE8000 platform are as follows e XFP 10GLR OC192SR e XFP 10GER OC192IR e XFP 10GZR OC192LR e XFP 10G MM SR XFP Connections The qualified XFPs include an optical transmitter and receiver pair integrated with Clock and Data Recovery CDR integrated circuits The XFPs provide high speed serial links at 10 3125 Gbps on single mode fibers The transmit side recovers and retimes the 10 Gbps serial data and passes it to a laser driver The laser driver biases and modulates a laser enabling data transmission over fiber through an LC connector The receive side recovers and retimes the 10 Gbps optical data stream from a photo detector trans impedance amplifier and passes it to an output driver See the label on the XFP for technology type and model XFP dimensions are e Height 12 5 mm e Width 18 35 mm e Length 71 1mm Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 26 E OL 16478 02 _ Chapter 2 Introduction to the Cisco SCE8000 Platform Introduction to SIPs and SPAs W The XFP operating temperature range is 0 C to 70 C Table 2 4 XFP Port Cabling Specifications XFP Wavelength Fiber Type XFP 10GLR OC192SR 1310 nm SMF XFP 10GER OC192IR 1550 nm SMF XFP 10GZR OC192LR 1550 nm SMF XFP 10G MM S
136. or or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Warning Read the installation instructions before connecting the system to the power source Warning This product requires short circuit overcurrent protection to be provided as part of the building installation Install only in accordance with national and local wiring regulations Site Requirements This section provides site power requirements for the Cisco SCE8000 chassis You should verify the site power prior to installation e Preventing Electrostatic Discharge Damage page 4 3 e Environmental Requirements page 4 3 e Power Requirements page 4 3 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 a2 E OL 16478 02 Chapter4 Installing the Cisco SCE8000 Chassis Preparing for Installation W Preventing Electrostatic Discharge Damage Electrostatic discharge ESD damage which can occur when electronic cards or components are improperly handled results in complete or intermittent failures Port adapters and blades consist of printed circuit boards that are fixed in metal carriers Electromagnetic interference EMI shielding and connectors are integral components of the carrier Although the metal carrier helps to protect the board from ESD use a preventive antistatic strap du
137. orm Model Information Model number Cisco SCE8000 10GBE Link Type 10 Gigabit Ethernet Number of Ports 2 or 4 Number of Links lor2 The Cisco SCE8000 is a transparent element with 10GBE links service throughput It can be installed inline in the network where the entire traffic passes through it or in receive only mode where it receives replication of the traffic through SPAN ports or optical splitters OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter2 Introduction to the Cisco SCE8000 Platform W Service Control Module SCE8000 SCM E Figure 2 1 Cisco SCE8000 Platform agar an The Cisco SCE8000 supports the following network insertion models e single appliance inline e single appliance receive only e cascade configuration e MGSCP configuration The Cisco SCE8000 platform is a 4 slot chassis hosting the following modules e One or two Service Control Modules SCE8000 SCM E that each contain special purpose fast path chipset traffic processors and control processor e One SPA Interface Processor card SCE8000 SIP that holds up to four SPA 10GBE interface modules e One optional optical bypass module hosting panel that holds up to two optical bypass modules In addition the Cisco SCE8000 chassis contains two power supply modules in a 1 1 configuration as well as a fan tray module Servic
138. our topology related parameters e Connection mode Can be any one of the following depending on the physical installation of the Cisco SCE8000 Refer to Connection Mode Parameter page 3 11 Inline single Cisco SCE8000 inline Receive only single Cisco SCE8000 receive only Inline cascade two inline Cisco SCE8000 platforms cascaded Receive only cascade two receive only Cisco SCE8000 platforms cascaded e Physically connected links In cascaded configurations this parameter defines the number of the link connected to the Cisco SCE8000 platform being configured Refer to Physically Connected Links Parameter page 3 12 It is applicable only in a cascade topology e Priority This parameter defines which is the primary Cisco SCE8000 Refer to Priority page 3 12 It is applicable only in a cascade topology e On failure This parameter determines whether the system cuts the traffic or bypasses it when the Cisco SCE8000 either has failed or is booting Traffic bypass can be achieved either through the external optical bypass device or through the internal bypass mechanism of the SPA interface processor It is not applicable to receive only topologies Refer to On Failure Mode Parameter page 3 12 These parameters are configured via the connection mode command Connection Mode Parameter The connection mode parameter refers directly to the physical topology in which the Cisco SCE8000 is installe
139. oving the Optical Bypass Module 9 25 Installing the Optical Bypass Module 9 25 Replacing the Optical Bypass Module without Disrupting Traffic on the Link cHaPTER A Using Optical Splitters with 10GBE Links A 1 Supported Configurations A 1 Unsupported Configuration A 2 9 26 E Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 About this Guide This preface describes who should read the Cisco SCE8000 Installation and Configuration Guide how it is organized and its document conventions This guide is for the networking or computer technician responsible for installing and configuring the SCE8000 platform on site To use this publication you should be familiar with telecommunications equipment and installation procedures as well as electronic circuitry and wiring practices You should also have experience as an electronic or electromechanical technician This installation guide explains the initial hardware installation and basic configuration procedures for the SCE8000 It contains procedures for unpacking and installing the device and performing basic configuration via the setup wizard After completing the installation and basic configuration procedures covered in this guide you will then use the appropriate companion publications to more completely configure your system This guide contains instructions on how to install and run the SCE8000 platform This guide assumes a basic familiarity with teleco
140. ow to Cable the 10GBE Line Interface Ports Step 1 Take the appropriate fiber optic cable see Fiber Specifications page 6 10 and plug it into the appropriate port on the 1OGBE interface on the SPA module in slot 3 of the Cisco SCE8000 See Figure 6 1 below Make sure to push on the connector until you hear a click which indicates that the connector is fully inserted and secured in the receptacle Always make sure that you insert the connector completely into the socket Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter6 Cabling the Line Ports and Completing the Installation Cabling the 10GBE Line Interface Ports W Figure 6 1 Cabling the 10GBE Interface 270979 Step2 Verify that the link LED is green If the link LED does not light try removing the network cable plug and reinserting it firmly into the module socket Cabling the 10GBE Line Interface Ports Using the External Optical Bypass Module Refer to Optical Bypass Module Connectivity page 6 8 for specific connectivity Figure 6 2 External Optical Bypass Module Line Interfaces 270978 Step 1 Take the appropriate fiber optic cable see Fiber Specifications page 6 10 and plug it into the appropriate port A or B on the external bypass module Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 Chapter6 Cabling the Line Ports and Completing the Installation WE Cabling the
141. p4 After the SPA is properly seated fasten the SPA in place with the captive installation screws Removing a SPA from a SIP To remove a SPA from a SIP refer toFigure 9 17 and do the following Step 1 At the SCE prompt type reload shutdown and press Enter to power down the Cisco SCE8000 platform before installing or removing any module Step 2 If attached remove any cables from the SPA Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter9 Removal and Replacement Procedures Removing and Replacing the Optical Bypass Module W Step 3 To remove the SPA from the SIP unfasten the captive installation screws on the SPA Step4 Grasp the handles of the SPA and pull the SPA from the SIP Removing and Replacing the Optical Bypass Module e Removing the Optical Bypass Module page 9 25 e Installing the Optical Bypass Module page 9 25 e Replacing the Optical Bypass Module without Disrupting Traffic on the Link page 9 26 Removing the Optical Bypass Module Step 1 Disconnect all cables Step2 Loosen the two captive screws on the module Step3 Pull the module out of the slot Place your other hand under the module to support the weight of the module Do not touch the module circuitry Step4 Place the module on antistatic foam or immediately reinstall it in another slot Step5 Ifthe slot is to remain empty install a module filler plate to keep dust out of the chassis and to maintain proper air
142. port This verifies that an active connection exists between the specified station and the management port The ping command sends an echo request packet to an IP address and then awaits a reply Ping output can help you evaluate path to host reliability delays over the path and whether the host can be reached or is functioning OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter5 Connecting the Management Interfaces WE Connecting the Management Interface EXAMPLE The following example displays a typical ping response where the target IP address is 10 10 10 20 C gt ping 10 10 10 20 pinging 10 10 10 20 PING 10 10 10 20 56 data bytes 64 bytes from host 10 10 10 20 icmp_seq 0 time 0 ms 64 bytes from host 10 10 10 20 icmp_seq 1 time 0 ms 64 bytes from host 10 10 10 20 icmp_seq 2 time 0 ms 64 bytes from host 10 10 10 20 icmp_seq 3 time 0 ms 10 10 10 20 PING Statistics 4 packets transmitted 4 packets received 0 packet loss round trip ms min avg max 0 0 0 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 amp CHAPTER Cabling the Line Ports and Completing the Installation This chapter provides instructions for cabling the Cisco SCE8000 10 Gigabit Ethernet ports for single cascaded and MGSCP topologies In a cascade topology this includes the cascade ports as well as the line ports The 10 Gigabit E
143. press Enter SCE8000 show logger device user file log counters Logger device User File Log counters Total info messages 1 Total warning messages 0 Total error messages 0 Total fatal messages 0 If there are Total error messages or Total fatal messages use the show logger device User File Log command to display details about the errors How to Load and Activate a Service Control Application The Cisco SCE8000 platform provides the basic functionalities of Service Control analysis and enforcement A Service Control solution requires that a Service Control application be loaded into the platform to take advantage of the unique SCE platform capabilities Loading and activating an application includes the following stages e Downloading the application provided as an SLI file to the Cisco SCE8000 disk e Activating the application e Configuring the application The detailed procedure of how to perform these operations is not specified and described in this manual For further details refer to the following documentation e Cisco Service Control Application for Broadband User Guide e Cisco Service Control Application for Broadband Reference Guide E Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 _ Chapter 6 Cabling the Line Ports and Completing the Installation Cascaded Systems W Cascaded Systems e How to Install a Cascaded System page 6 15 e CLI Commands for Ca
144. ptions Service Control capabilities that cannot be used in an asymmetric routing topology include the following e Subscriber redirect e Subscriber notification e Any kind of subscriber integration Use subscriber less mode or anonymous subscriber mode instead OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter3 Cisco SCE8000 Topology and Topology Related Parameters HZ Asymmetric Routing Topology Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 Em OL 16478 02 A p epee Installing the Cisco SCE8000 Chassis This chapter describes how to install a Cisco SCE8000 chassis Warning Before you install operate or service the system read the Regulatory Compliance and Safety Information for the Cisco SCE8000 Platform This guide contains important safety information you should know before working with the system Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Warning A Before working on a chassis or working near power supplies unplug the power cord on AC units disconnect the power at the circuit breaker on DC units Warning A The plug socket combination must be accessible at all times because it serves as the main disconnecting device Warning A This unit is intended for installation in restricted access areas A restricted access area can
145. quate spacing between racks using the information in the following table Keep all of the vents clear of obstructions including dust and foreign conductive material and away from the exhaust ports of other equipment Table 4 1 Chassis Airflow Requirements Minimum Minimum Horizontal Airflow Intake Airflow Exhaust Air Filter Option Clearance walls Separation Right side Left side Not applicable 6 in 15 cm 12 in 30 5 Power Requirements A Warning Read the installation instructions before connecting the system to the power source Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 PEN Chapter 4 Installing the Cisco SCE8000 Chassis W Preparing for Installation Follow these requirements when preparing your site for the Cisco SCE8000 installation e The redundant power configuration provides a second identical power supply to ensure that power to the chassis continues uninterrupted if one power supply fails or input power on one line fails e Connect each of the two power supplies to a separate input power source If you fail to do this your system might be susceptible to total power failure due to a fault in the external wiring or a tripped circuit breaker e To prevent a loss of input power be sure that the total maximum load on each circuit supplying the power supplies is within the current ratings of the wiring and breakers e In some systems you might use an uninte
146. quipment Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 ao OL 16478 02 Chapter4 Installing the Cisco SCE8000 Chassis Site Planning Checklist Preparing for Installation Table 2 6 lists the site planning activities that you should perform prior to installing the Cisco SCE8000 chassis Completing each activity helps ensure a successful installation Table 4 3 Task No Site Planning Checklist Planning Activity Verified By Time Date 1 Space evaluation Space and layout Floor covering Impact and vibration Lighting Maintenance access Environmental evaluation Ambient temperature Humidity Altitude Atmospheric contamination Airflow Power evaluation Input power type Power receptacles Receptacle proximity to the equipment Dedicated separate circuits for redundant power supplies UPS for power failures DC systems Proper gauge wire and lugs Grounding evaluation Circuit breaker size CO ground AC and DC powered systems Cable and interface equipment evaluation Cable type Connector type Cable distance limitations EMI evaluation Distance limitations for signaling Site wiring RFI levels OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter 4 Installing the Cisco SCE8000 Chassis HZ installing the Cisco SCE8000 Chassis in the Rack Installing the Cisco SCE8000 Chassi
147. r Log page 8 12 e How to View the User Log Counters page 8 13 e How to View the Non volatile Counter For the User file log Only page 8 13 How to Copy the User Log to an External Source You can view the log file by copying it to an external source This command copies both log files to any external host running a FTP server Step 1 From the SCE prompt type logger get user log file name ftp username password ipaddress path and press Enter How to Copy the User Log to an Internal Location You can view the log file by copying it to disk This command copies both log files to the local SCE platform disk Step1 From the SCE prompt type logger get user log file name target filename and press Enter How to View the User Log amp Note This command is not recommended when the user log is large Copy a large log to a file to view it see How to Copy the User Log to an External Source page 8 12 Step 1 From the SCE prompt type more user log and press Enter How to Clear the User Log You can clear the contents of the user log at any time The user log contains important information regarding the functioning of the system It is recommended that a copy be made before the log is cleared Step1 From the SCE prompt type clear logger device user file log and press Enter Step2 The system asks Are you sure Step3 Type y and press Enter Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16
148. r Supply This section covers the DC input power supply installation procedure for the Cisco SCE8000 chassis amp Note The DC return is to remain isolated from the system frame and chassis DC I A Warning Before performing any of the following procedures ensure that power is removed from the DC circuit Step 1 Power supply ground is required Install the PWR 2700 DC 4 power supply ground as described in this procedure Note The system ground connection with the PWR 2700 DC 4 power supply in a Cisco SCE8000 is provided by the PWR 2700 DC 4 power supply ground Additionally you can connect a system earth ground Note You must always connect the PWR 2700 DC 4 power supply ground amp Note You must connect the PWR 2700 DC 4 power supply ground for both power supplies Note If you intend to use an additional system earth ground ensure that the system ground connection has been made For ground connection installation instructions see Connecting the System Ground page 4 16 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I OL 16478 02 g o7 Chapter9 Removal and Replacement Procedures W Removing and Replacing the Power Supply Step 2 Step 3 Step 4 A Remove the plastic bag attached to the front panel and put aside This bag contains two plastic terminal block barriers two cable ties and two cable holder covers Verify that power is off to the DC
149. r both SCE platforms is Inline cascade e Physically connected links For each of the cascaded SCE platforms this parameter defines the number of the link Link 0 or Link 1 connected to this SCE platform e Priority For each of the cascaded SCE platforms this parameter defines whether it is the primary or secondary device e On failure For each of the cascaded SCE platforms this parameter determines whether the system cuts the traffic or bypasses it via an external optical bypass module when the SCE platform either has failed or is booting If either the bypass or external bypass option is configured the optical bypass module must be properly installed If an optical bypass device is not detected the command is executed but a warning is issued The system then enters warning mode until either the command is changed or the presence of an optical bypass device is detected How to Configure the Connection Mode Use the following command to configure the connection mode including the following parameters Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 u OL 16478 02 _ Chapter 6 Cabling the Line Ports and Completing the Installation Step 1 Cascaded Systems W e inline e physically connected links e behavior upon failure of the SCE platform e primary secondary From the Cisco SCE8000 config if prompt type connection mode inline cascade physically connected links link Ollink 1 prior
150. rations 7 5 Viewing Configurations 7 5 Saving or Changing the Configuration Settings 7 6 6 16 Example for Saving or Changing the Configuration Settings 7 7 Restoring a Previous Configuration 7 8 Example for Restoring a Previous Configuration 7 8 How to Display the SCE Platform Version Information 7 9 Example for Displaying the SCE Platform Version Information How to Display the SCE Platform Inventory 7 12 Examples for Displaying the SCE Platform Inventory 7 12 Displaying the SCE Platform Inventory FRUs Only 7 12 Displaying the Complete SCE Platform Inventory 7 13 How to Display the System Uptime 7 16 Example for Displaying the System Uptime 7 16 Rebooting and Shutting Down the SCE Platform 7 16 Rebooting the SCE Platform 7 16 Examples for Rebooting the SCE Platform 7 16 How to Shut Down the SCE Platform 7 17 Examples for Shutting Down the SCE Platform 7 17 7 9 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 CHAPTER 8 CHAPTER 9 Troubleshoot ing 8 1 Troubleshooting Overview 8 1 Information About Troubleshooting Tools 8 2 CLI Commands for Troubleshooting 8 2 Checking the LEDs 8 4 Problem Solving Using a Subsystems Approach 8 6 Identifying Startup Problems 8 6 Troubleshooting the Power Subsystem 8 7 Troubleshooting the Firmware Package Installation 8 8 Troubleshooting the Management Subsystem 8 8 Troubleshooting the Link Interface Subsystem 8 10 Troubleshooting with the User Log 8 11
151. revconf Up to nine versions of the startup configuration file are saved namely config txl config tx9 where config tx1 is the most recently saved file You can view the old startup configuration files using the CLI command more Restoring a previous startup configuration means renaming the file so it overwrites the startup configuration config txt file Step1 At the SCE prompt type more system prevconf config tx1 to view the configuration file The system displays the configuration information stored in the file Step2 Read the configuration information to make sure it is the configuration you want to restore Note that you cannot undo the configuration restore command Step3 Type copy system config tx1 system config txt The system sets the startup configuration to the configuration from config tx Example for Restoring a Previous Configuration The following example displays a saved configuration file and then restores the file to overwrite the current configuration SCE more system prevconf config tx1 This is a general configuration file running config Created on 12 07 41 UTC SUN May 11 2008 cli type 1 version 1 no management agent notifications notification list 1417 1418 804 815 1404 1405 1406 1407 1408 400 no management agent notifications notification list 402 421 440 441 444 445 446 450 437 457 no management agent notifications notification list 3593 3594 3595 10040 snmp server community public ro
152. ring handling Following are guidelines for preventing ESD damage e Always use an ESD wrist or ankle strap and ensure that it makes good skin contact e Connect the equipment end of the strap to an unfinished chassis surface e When installing a component use any available ejector levers or captive installation screws to properly seat the bus connectors in the backplane or midplane These devices prevent accidental removal provide proper grounding for the system and help to ensure that bus connectors are properly seated e When removing a component use any available ejector levers or captive installation screws to release the bus connectors from the backplane or midplane e Handle carriers by available handles or edges only avoid touching the printed circuit boards or connectors e Place a removed component board side up on an antistatic surface or in a static shielding container If you plan to return the component to the factory immediately place it in a static shielding container e Avoid contact between the printed circuit boards and clothing The wrist strap only protects components from ESD voltages on the body ESD voltages on clothing can still cause damage e Never attempt to remove the printed circuit board from the metal carrier A Caution For safety periodically check the resistance value of the antistatic strap The measurement should be between 1 and 10 megohm Mohm Environmental Requirements Ensure ade
153. rol functions including granular bandwidth BW metering and shaping quota management and redirection using application layer stateful real time traffic transaction processing This requires highly adaptive protocol and application level intelligence e Programmability The ability to quickly add new protocols and adapt to new services and applications in the service provider environment Programmability is achieved using the Cisco Service Modeling Language SML Programmability allows new services to be deployed quickly and provides an easy upgrade path for network application or service growth e Robust and flexible back office integration The ability to integrate with existing third party systems at the service provider including provisioning systems subscriber repositories billing systems and OSS systems The SCE provides a set of open and well documented APIs that allows a quick integration process e Scalable high performance service engines The ability to perform all of these operations at wire speed Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter1 Cisco Service Control Overview SCE Platform Description W SCE Platform Description The SCE family of programmable network devices performs application layer stateful flow inspection of IP traffic and controls the traffic based on configurable rules The SCE platform is a network device that uses ASIC components and reduc
154. rruptible power supply UPS to protect against power failures at your site Avoid UPS types that use ferroresonant technology These UPS types can become unstable with systems like the Cisco SCE8000 which can have substantial current draw fluctuations due to bursty data traffic patterns Power Connection Guidelines This section provides the guidelines for connecting the Cisco SCE8000 AC and DC power supplies to the site power source e AC Powered Systems page 4 4 e DC Powered Systems page 4 10 e Site Planning Checklist page 4 11 AC Powered Systems e Each chassis power supply should have its own dedicated branch circuit e The circuit must be protected by a dedicated two pole circuit breaker For North America the circuit breaker should be rated at 20A For everywhere else the circuit breaker should be sized according to the power supply input rating and local or national code requirements e The AC power receptacles used to plug in the chassis must be the grounding type The grounding conductors that connect to the receptacles should connect to protective earth ground at the service equipment A Warning Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available A Warning The plug socket combination must be accessible at all times b
155. s a 5 second period at most during which the link is forced down cutoff functionality Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 28 E OL 16478 02 Chapter 2 Introduction to the Cisco SCE8000 Platform The Cisco SCE8000 Optical Bypass W e During a power failure The Cisco SCE8000 has two power supplies A power failure occurs only when both of them fail In a case where the Cisco SCE8000 platform must be replaced it is possible to remove the bypass modules from the SCE8000 chassis without disconnecting them from the network and then reinstall them in the new SCE platform so that traffic links are preserved even in a case of complete failure and replacement of the Cisco SCE8000 platform See Replacing the Optical Bypass Module without Disrupting Traffic on the Link page 9 26 Optical Bypass Functionality The optical bypass module is connected bump in the wire in the 10 GBE link It is then connected to the Cisco SCE8000 platform with two types of connections e 10GBE optical connections for data link traffic 10 GBE connections from the optical bypass module to one pair of the 10GBE SPA ports e Control connection Connection to the RJ 11 External Bypass connector on the SCE8000 SCM so the optical bypass is activated if the Cisco SCE8000 platform fails Optical Bypass Module Connectivity The optical bypass module functions as follows e Under normal conditions the bypass module directs tr
156. s in the Rack This section describes how to install a Cisco SCE8000 platform in a rack For first time installations perform the procedures in the following sections in the order listed e Unpacking the Cisco SCE8000 Chassis page 4 12 e Installation Guidelines page 4 12 e Required Tools page 4 13 e Installing the Chassis Brackets page 4 13 e Installing the Chassis in the Rack page 4 14 e Installing an Optical Bypass Module page 4 15 Note Before starting the installation procedures in this chapter see the Site Planning Checklist page 4 11section to verify that all site planning activities were completed Unpacking the Cisco SCE8000 Chassis pP Tip Do not discard the shipping container when you unpack the Cisco SCE8000 Flatten the shipping cartons and store them with the pallet You will need these containers if you need to move or ship the Cisco SCE8000 in the future Perform the following to check the contents of the shipping container e Check the contents of the accessories kit against the list of accessories in the Cisco SCE8000 Component List page 2 14 and the packing slip Verify that you received all listed equipment which should include the following Hardware and software documentation if ordered Optional equipment that you ordered such as network interface cables transceivers or special connectors e Check the modules in each slot Ensure that the configuration matches the packing
157. scaded Systems page 6 16 How to Install a Cascaded System Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step7 Step 8 This section outlines the installation procedures for a redundant solution with two cascaded Cisco SCE8000 platforms Refer to the Cisco Service Control Engine SCE CLI Command Reference for details of the CLI commands When working with two Cisco SCE8000 platforms with split flow and redundancy it is extremely important to follow this installation procedure Install both Cisco SCE8000 platforms power them up and perform the initial system configuration See Chapter 4 Installing the Cisco SCE8000 Chassis and Chapter 5 Connecting the Management Interfaces and Starting the Cisco SCE8000 Platform page 7 1 To maintain link continuity at all times including during the reload sequence and power failure events optical bypass modules must be installed Connect both Cisco SCE8000 platforms to the management station See Connecting the Management Interface page 5 4 Connect the cascade ports See Dual Link Two Cisco SCE8000s Topology page 6 3 The cascade ports must be either be connected directly in Layer dark fibers or using the following procedure to connect through a switch e Connect port 3 2 0 from box A and port 3 3 0 from box B to a single switch Configure them both on the same access VLAN which will be used only by the interfaces connected to these ports No other inter
158. sco SCE8000 Topologies A single Cisco SCE8000 supports both single 10GBE link and dual 10GBE link topologies e Single Link Inline Topology page 3 4 e Dual link Inline Installation page 3 4 e Single Link Receive only Topology page 3 5 e Dual Link Receive Only Topology page 3 5 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 PEN Chapter3 Cisco SCE8000 Topology and Topology Related Parameters W Physical Topologies Single Link Inline Topology Typically the Cisco SCE8000 is connected in a full duplex 1OGBE link between two devices Router BRAS etc When the Cisco SCE8000 is installed as an inline installation it physically resides on the data link between the subscribers and the network Figure 3 2 Single Link Inline Topology Subscriber m When configuring the Cisco SCE8000 an inline installation is referred to as inline connection mode Dual link Inline Installation In this topology one Cisco SCE8000 is connected inline in two full duplex 10GBE links In case the two links are load shared asymmetrical routing might occur and some of the flows may be split that is the upstream packets of the flow go on one link and the downstream packets go on the other link When installed in this topology the Cisco SCE8000 completely overcomes this phenomenon and provides its normal functionality as if asymmetrical routing were not occurring in the two links
159. stem Three main categories of RDRs include e Transaction RDRs Records generated for each transaction where a transaction is a single event detected in network traffic The identification of a transaction depends on the particular application and protocol e Subscriber Usage RDRs Records generated per subscriber describing the traffic generated by that subscriber for a defined interval e Link RDRs Records generated per link describing the traffic carried on the link for a defined interval Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Introduction to the Cisco SCE8000 Platform This chapter provides an introduction to the Cisco SCE8000 1OGBE platform the Service Control hardware component e Information About the SCE Platform page 2 1 e Service Control Module SCE8000 SCM E page 2 2 e Introduction to SIPs and SPAs page 2 4 e The SCE8000 SIP page 2 7 e The l Port 1OGBE SPA Interface Module page 2 7 e The Cisco SCE8000 Optical Bypass page 2 8 e Checking the Shipping Container Contents page 2 13 e Cisco SCE8000 Installation Checklist page 2 15 Information About the SCE Platform The Service Control Engine SCE platform which is the hardware component of the Cisco Service Control solution is designed to support observation analysis and control of Internet IP traffic The following table summarizes model information for the Cisco SCE8000 platform Table 2 1 SCE Platf
160. supply 1 DESCR PWR 2700 DC 4 PWR 2700 DC 4 VID V03 SN APQ1049000S SCE8000 optic 3 0 0 DESCR XFP 10GLR O0C192SR XFP 10GLR OC192SR VID V02 SN AGA1142N4B7 SCE8000 optic 3 1 0 DESCR XFP 10GLR 0C192SR XFP 10GLR OC192SR VID V02 SN AGA1142N4AL SCE8000 optic 3 2 0 DESCR XFP 10GLR O0C192SR XFP 10GLR OC192SR VID V02 r SN AGA1141N43R SCE8000 SIP E Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter7 Basic Cisco SCE8000 Platform Operations How to Display the SCE Platform Inventory W NAME SCE8000 optic 3 3 0 DESCR XFP 10GLR OC192SR PID XFP 10GLR 0C192SR VID V02 SN AGA1143N4JN NAME SCE8000 traffic processor 1 DESCR SCE8000 traffic processor PID VID SN NAME SCE8000 traffic processor 2 DESCR SCE8000 traffic processor PID VID SN NAME SCE8000 traffic processor 3 DESCR SCE8000 traffic processor PID VID SN NAME SCE8000 traffic processor 4 DESCR SCE8000 traffic processor PID VID SN NAME SCE8000 traffic processor 5 DESCR SCE8000 traffic processor PID VID SN NAME SCE8000 traffic processor 6 DESCR SCE8000 traffic processor PID VID SN NAME SCE8000 traffic processor 7 DESCR SCE8000 traffic processor PID VID SN NAME SCE8000 traffic processor 8 DESCR SCE80
161. t includes separation between ingress and egress traffic and multiple SPAN ports destinations Guidelines for single link receive only topologies e If only two SPA modules are installed only two SPA modules are required for a single link they must be installed in bays 0 and 1 of the SPA jacket card e Receive only topologies use only Receive fibers Single link receive only connectivity e Port 3 0 0 Link 0 Split of optic signal transmitted by subscribers side e Port 3 1 0 Link 0 Split of optic signal transmitted by network side Dual Link Single Cisco SCE8000 Topologies In this topology one Cisco SCE8000 is connected to two full duplex 1OGBE links The Cisco SCE8000 may be either inline to support both monitoring and traffic control functionality or receive only for traffic monitoring functionality only Guidelines for dual link topologies e SPA modules 0 and 1 are connected to the first link Link 0 e SPA modules 2 and 3 are connected to the second link Link 1 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 e2 E OL 16478 02 Chapter6 Cabling the Line Ports and Completing the Installation Connecting the Line Ports to the Network Ml e Dual link inline topologies require both Receive and Transmit fibers e Dual link receive only topologies use only Receive fibers e To maintain link continuity at all times on both links when using the inline topology two optical bypass modules should be
162. tandby S 2 3 N 4 4 If Cisco SCE8000 3 is the redundant platform Links 5 amp 6 would be connected to it and the actual connections might look like this S 0 1 Cisco SCE8000 1 3 0 0 N 2 2 Cisco SCE8000 1 3 1 0 S 0 2 Cisco SCE8000 1 3 2 0 N 2 4 Cisco SCE8000 1 3 3 0 S 0 3 Cisco SCE8000 2 3 0 0 N 3 1 Cisco SCE8000 2 3 1 0 S 1 3 Cisco SCE8000 2 3 2 0 N 3 2 Cisco SCE8000 2 3 3 0 S 1 5 Cisco SCE8000 3 3 0 0 N 3 4 Cisco SCE8000 3 3 1 0 S 2 3 Cisco SCE8000 3 3 2 0 N 4 4 Cisco SCE8000 3 3 3 0 Dual Routers MGSCP Connectivity Four links on each router would require four Cisco SCE8000 platforms For the sake of simplicity we assume that the EC ports are the same on both routers Connect the ordered pairs each pair of EC ports to a pair of Subscriber Network ports in a Cisco SCE8000 platform Cisco SCE8000 1 Link 1 on both routers Cisco SCE8000 2 Link 2 on both routers Cisco SCE8000 3 Link 3 on both routers Cisco SCE8000 4 Link 4 on both routers The actual connections might look like this Router 1 S 0 1 Cisco SCE8000 1 3 0 0 Router 2 S 0 1 Cisco SCE8000 1 3 2 0 Router 1 N 2 2 Cisco SCE8000 1 3 1 0 Router 2 N 2 2 Cisco SCE8000 1 3 3 0 Router 1 S 0 2 Cisco SCE8000 2 3 0 0 Router 2 S 0 2 Cisco SCE8000 2 3 2 0 Router 1 N 3 1 Cisco SCE8000 2 3 1 0 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 _ Chapter 6 Cabling the Line Ports and Completi
163. th a blank filler plate SPA BLANK inserted in all empty subslots Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 P24 E OL 16478 02 Chapter 2 Introduction to the Cisco SCE8000 Platform Introduction to SIPs and SPAs W Specifying the SIP Subslot Location for a SPA Cisco SCE8000 SIP subslots begin their numbering with 0 and have a horizontal orientation Figure 2 3 shows the subslot numbering for the Cisco SCE8000 SIP The Cisco SCE8000 SIP supports four subslots for the installation of SPAs as follows e SIP subslot 0O Top left subslot e SIP subslot 1 Top right subslot e SIP subslot 2 Bottom left subslot e SIP subslot 3 Bottom right subslot Figure 2 3 SPA Module Subslot Location Front of SCE8000 SIP Sub slot 0 Sub slot 1 Sub slot 2 Sub slot 3 270900 Shared Port Adapters The SPA supported by the Cisco SCE8000 SIP is the 1 Port 10 Gigabit Ethernet SPA SPA 1X10GE L V2 The following list describes some of the general characteristics of a SPA e A SPA is a modular type of port adapter that inserts into a subslot of a compatible SIP carrier card to provide network connectivity and increased interface port density The Cisco SCE8000 SIP can hold up to four SPAs Since the interfaces are connected in subscriber network pairs either two or four SPAs must be installed e The supported SPA is a single height SPAs which inserts into one SIP subslot
164. the Current Connection Mode page 6 18 e How to View the Current Link Mode page 6 18 e How to View the Current Link Mappings page 6 18 How to View the Current Connection Mode Step1 From the Cisco SCE8000 prompt type show interface linecard 0 connection mode and press Enter How to View the Current Link Mode Step1 From the Cisco SCE8000 prompt type show interface linecard 0 link mode and press Enter How to View the Current Link Mappings Step1 From the Cisco SCE8000 prompt type show interface linecard 0 physically connected links and press Enter Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 lt OL 16478 02 Basic Cisco SCE8000 Platform Operations This chapter describes how to start up the Cisco SCE8000 platform reboot and shutdown It also describes how to manage configurations e Starting the Cisco SCE8000 Platform page 7 1 e Managing Cisco SCE8000 Configurations page 7 5 e How to Display the SCE Platform Version Information page 7 9 e How to Display the SCE Platform Inventory page 7 12 e How to Display the System Uptime page 7 16 e Rebooting and Shutting Down the SCE Platform page 7 16 Starting the Cisco SCE8000 Platform The procedures for starting the Cisco SCE8000 platform are explained in the following sections e Checking Conditions Prior to System Startup page 7 1 e Performing Complex Configurations page 7 2 e Starting the System and Observing Initial Conditions page
165. the module part of the way out of the slot Pull the module out of the slot Place your other hand under the module to support the weight of the module Do not touch the module circuitry Place the module on antistatic foam or immediately reinstall it in another slot If the slot is to remain empty install a module filler plate to keep dust out of the chassis and to maintain proper airflow through the chassis Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 m OL 16478 02 Chapter9 Removal and Replacement Procedures Removing and Replacing Modules W Inserting and Removing a Module Detail Refer to the following illustrations for detailed views of e A captive screw e The ejector lever e The slot guide Figure 9 14 Module Installation and Removal SCEBOO0 ScyE 270902 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 a 919 Chapter 9 Removal and Replacement Procedures HZ Removing and Replacing Modules Verifying the Installation Step 1 Use the show version command to verify that the system software and firmware are installed properly From the SCE gt prompt type show version and press Enter This example shows the output of the show version command System version Version 3 1 6S Build 279 Build time Jun 10 2008 19 27 47 Change list 335658 Software version is Version 3 1 6S Build 279 Hardware information is kern
166. the system and help to ensure that bus connectors are properly seated e When removing a component use any available ejector levers or captive installation screws to release the bus connectors from the backplane or midplane e Handle carriers by available handles or edges only avoid touching the printed circuit boards or connectors e Place a removed component board side up on an antistatic surface or in a static shielding container If you plan to return the component to the factory immediately place it in a static shielding container e Avoid contact between the printed circuit boards and clothing The wrist strap only protects components from ESD voltages on the body ESD voltages on clothing can still cause damage e Never attempt to remove the printed circuit board from the metal carrier A Caution For safety periodically check the resistance value of the antistatic strap The measurement should be between 1 and 10 megohm Mohm Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 lt OL 16478 02 Chapter9 Removal and Replacement Procedures Supported Hardware W Supported Hardware The Cisco SCE8000 platform supports the following hardware e One Service Control Module SCE8000 SCM E with an optional redundant Service Control Module FRU e One SPA jacket module SCE8000 SIP with either two or four SPA 1OGBE interface modules all FRU e Up to two optical bypass modules installed i
167. thernet ports are located on the 10G SPA modules which are installed in the SCE8000 SIP module in slot 3 of the Cisco SCE8000 chassis Note amp When installing a cascaded system it is extremely important to follow the sequence of procedures outlined in the section Cascaded Systems page 6 15 Note When installing an External Optical Bypass module the Cisco SCE8000 line ports are connected to the module See Cabling the 10GBE Line Interface Ports Using the External Optical Bypass Module page 6 11 for complete instructions e Connecting the Line Ports to the Network page 6 1 e The Optical Bypass Module page 6 8 e Cabling the 10GBE Line Interface Ports page 6 9 e How to Load and Activate a Service Control Application page 6 14 e Cascaded Systems page 6 15 Connecting the Line Ports to the Network e Single Link Inline Topology page 6 2 e Single Link Receive only Topology page 6 2 e Dual Link Single Cisco SCE8000 Topologies page 6 2 e Dual Link Two Cisco SCE8000s Topology page 6 3 e Multi Gigabit Service Control Platforms MGSCP Topologies page 6 4 OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter6 Cabling the Line Ports and Completing the Installation HZ Connecting the Line Ports to the Network Single Link Inline Topology In the inline topology the Cisco SCE8000 resides physically on the 10 GBE Ten Gigabit Ethernet link between the subs
168. they must offer value added services to derive more revenue from the traffic and services running on their networks Cisco service control solutions allow the service provider to capture profits from IP services through detailed monitoring precise real time control and awareness of applications as they are delivered Service Control for Broadband Service Providers Service providers of any access technology DSL cable mobile and so on targeting residential and business consumers must find new ways to get maximum leverage from their existing infrastructure while differentiating their offerings with enhanced IP services The Cisco service control application for broadband adds a layer of service intelligence and control to existing networks that can OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter1 Cisco Service Control Overview HI Cisco Service Control Capabilities e Report and analyze network traffic at subscriber and aggregate level for capacity planning e Provide customer intuitive tiered application services and guarantee application service level agreements SLAs e Implement different service levels for different types of customers content or applications e Identify network abusers who are violating the acceptable use policy AUP e Identify and manage peer to peer traffic NNTP news traffic and spam abusers e Enforce the AUP e Integrate Service Control solutions easi
169. tion screws See Figure 9 1 Warning Step 5 Step 6 A Power supply captive installation screws must be tight to ensure protective grounding continuity Plug the power cord into the power supply Connect the other end of the power cord to an AC input power source Caution Step 7 Step 8 In a system with dual power supplies connect each power supply to a separate input source In case of a power source failure the second source will most likely still be available Turn the switch on the power supply to the On I position Verify power supply operation by checking the power supply LEDs The power supply LEDs should be in the following states e INPUT OK LED is green e FAN OK LED is green e OUTPUT FAIL LED is not lit If the LEDs indicate a power problem see Identifying Startup Problems page 8 6 for troubleshooting information Removing a DC Input Power Supply A Warning Before performing any of the following procedures ensure that power is removed from the DC circuit Warning Voltage is present on the backplane when the system is operating To reduce risk of an electric shock keep hands and fingers out of the power supply bays and backplane areas Step 1 Verify that power is off to the DC circuit connected to the DC input power supply you are removing Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 I oL 16478 02 m Chapter9 Removal and Replacement Procedures
170. to the RS 232 serial cable until you hear a click which indicates that the connector is fully inserted and secured in the receptacle Gently pull on the plug to confirm whether the plug is locked into the socket Connect the other end of the serial cable with an attached DB 9 or DB 25 connector to the VT100 compatible local serial terminal Make sure the local terminal is configured as a VT 100 terminal according to the fixed Cisco SCE8000 CON port parameters Make sure that the Cisco SCE8000 is powered on and has been allowed to complete booting this process may take several minutes Press Enter several times until the Cisco logo appears on the local terminal Initial Setup Parameters At this point there are several basic global parameters that must be correctly configured in order for the SCE platform to communicate properly with the outside world The following is a very brief summary of the initial setup parameters and commands For more information refer to the Cisco SCE8000 Software Configuration Guide e IP address and subnet mask of the Cisco SCE8000 platform itself This is the IP address used by the GBE management interface e IP address of the default gateway e Hostname The hostname is used to identify the SCE platform It appears as part of the CLI prompt and is also returned as the value of the MIB II object sysName The maximum length is 20 characters The default hostname is SCE8000 e Pass
171. type 1 version 1 no management agent notifications notification list 1417 1418 804 815 1404 1405 1406 1407 1408 400 no management agent notifications notification list 402 421 440 441 444 445 446 450 437 457 no management agent notifications notification list 3593 3594 3595 10040 snmp server community public ro RDR formatter forwarding mode multicast RDR formatter destination 10 56 96 26 port 33000 category number 1 priority 100 RDR formatter destination 10 56 96 26 port 33000 category number 2 priority 100 RDR formatter destination 10 56 96 26 port 33000 category number 3 priority 100 OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter7 Basic Cisco SCE8000 Platform Operations W Managing Cisco SCE8000 Configurations RDR formatter destination 10 56 96 26 port 33000 category number 4 priority 100 interface LineCard 0 connection mode inline on failure external bypass no silent no shutdown attack filter subscriber notification ports 80 replace spare memory code bytes 3145728 interface GigabitEthernet 1 1 ip address 10 56 96 46 255 255 252 0 interface TenGigabitEthernet 3 0 0 bandwidth 10000000 burst size 50000 global controller 0 name Default Global Controller interface TenGigabitEthernet 3 1 0 bandwidth 10000000 burst size 50000 global controller 0 name Default Global Controller interface TenGigabitEthernet 3 2 0 bandwidth 10000000 burst size 50000 global controller 0 n
172. uld be connected to it and the actual connections might look like this e Router 1 S 0 1 Cisco SCE8000 1 3 0 0 e Router 2 S 0 1 Cisco SCE8000 1 3 2 0 e Router 1 N 2 2 Cisco SCE8000 1 3 1 0 e Router 2 N 2 2 Cisco SCE8000 1 3 3 0 e Router 1 S 0 2 Cisco SCE8000 2 3 0 0 e Router 2 S 0 2 Cisco SCE8000 2 3 2 0 e Router 1 N 2 4 Cisco SCE8000 2 3 1 0 e Router 2 N 2 4 Cisco SCE8000 2 3 3 0 OL 16478 02 Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 E Chapter6 Cabling the Line Ports and Completing the Installation E The Optical Bypass Module e Router 1 S 0 3 Cisco SCE8000 3 3 0 0 e Router 2 S 0 3 Cisco SCE8000 3 3 2 0 e Router 1 N 3 1 Cisco SCE8000 3 3 1 0 e Router 2 N 3 1 Cisco SCE8000 3 3 3 0 e Router 1 S 1 3 Cisco SCE8000 4 3 0 0 e Router 2 S 1 3 Cisco SCE8000 4 3 2 0 e Router 1 N 3 2 Cisco SCE8000 4 3 1 0 e Router 2 N 3 2 Cisco SCE8000 4 3 3 0 e Router 1 S 1 5 Cisco SCE8000 5 3 0 0 e Router 2 S 1 5 Cisco SCE8000 5 3 2 0 e Router 1 N 3 4 Cisco SCE8000 5 3 1 0 e Router 2 N 3 4 Cisco SCE8000 5 3 3 0 The Optical Bypass Module The external optical bypass module is an optional component that provides additional protection by enabling automatic preservation of the network 10GBE link For more information regarding the external bypass module refer to The Cisco SCE8000 Optical Bypass page 2 8 There are two installation options for the optical bypass module
173. unctioning properly are explained in the following sections e Verifying Operational Status page 7 3 e Viewing the User Log Counters page 7 3 e Viewing the Ten Gigabit Ethernet Port Status page 7 4 e Viewing the Ten Gigabit Ethernet Counters page 7 4 Verifying Operational Status Step 1 Step 2 After all the ports are connected verify that the Cisco SCE8000 is not in a Warning state On the front panel of the Service Control module examine the Status LED it should be green To display the operation status of the system at the Cisco SCE8000 prompt type show system operation status and press Enter A message displaying the operation status of the system appears If the system is operating in order the following message appears System Operation status is Operational If the Status LED is red or flashing amber the following message appears System Operation status is Warning Description 1 Power Supply problem 2 Line feed problem 3 Amount of External bypass devices detected is lower than expected amount Viewing the User Log Counters Step 1 View the user log for errors that occurred during the installation process At the SCE prompt type show logger device user file log counters and press Enter Examples for Viewing the User Log Counters The following example shows the current User File Log device counters SCE show logger device user file log counters Logger device User File Log counters Total
174. urrent Cisco SCE8000 operational status Once boot is complete the operational status can be displayed using CLI command show system operation status Table 8 2 Cisco SCE8000 Operational States Cisco SCE8000 Operational Troubleshooting Overview W Status Description Status LED State Booting Initial state after reset Amber Operational Cisco SCE8000 becomes operational after completing the Steady green following process e Boot is completed e Power on self tests are completed without failure e Platform configuration is applied Warning Cisco SCE8000 is fully operational as above but one of the Flashing amber following occurred e GBE Management port link is down e Internal temperature above threshold e Internal voltage not in expected range e Fan problem e Power supply problem e Insufficient space on the disk Note If the condition that caused the Cisco SCE8000 to be in Warning state is resolved for example link is up the Cisco SCE8000 reverts to Operational state Failure System is in Failure state after Boot due to one of the following Red conditions e Power on test failure e Three abnormal reboots in less than 30 minutes e Platform configured to enter Failure mode consequent to failure induced reboot this is configurable using CLI command e Severe system health problem such as extensive overheating or voltage out of correct operating range Note Depending on the cause of failure the management interfa
175. ving Initial Conditions After installing your Cisco SCE8000 platform and connecting cables complete the following steps to start the Cisco SCE8000 platform Step 1 Make sure the power cables are connected to the Cisco SCE8000 platform Step2 Plug the AC power supply cables into the AC power source or make sure the circuit breakers at the DC panels are turned to the on position Turn on the switches on both power supplies Step3 Listen for the fans you should immediately hear them operating Step4 During the boot process observe the following LEDs on the SCE8000 SCM E e The Power LEDs should be green e Optical Bypass LED should be green while the Cisco SCE8000 is in bypass and unlit when the optical bypass is turned off e The Status LED should be a constant amber while booting After a successful boot the Status LED is steady green amp Note It takes a several minutes for the Cisco SCE8000 to boot and for the status LED to change from amber to green What to Do Next If the system does not complete each of the steps in the startup procedure proceed to Identifying Startup Problems page 8 6 for troubleshooting recommendations and procedures Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 Chapter 7 Basic Cisco SCE8000 Platform Operations Final Tests Starting the Cisco SCE8000 Platform W The procedures for performing the final tests to verify that the Cisco SCE8000 is f
176. wer or turning on the Cisco SCE8000 chassis Required Tools and Equipment To connect the system ground you need the following tools and materials e One grounding lug e Two M4 metric hex head screws with locking washers amp Note The grounding lug and M4 hex head screws with locking washers are provided in kit 69 0815 01 e One grounding wire The grounding wire must be sized according to local and national installation requirements Depending on the power supply and system a 12 AWG conductor or larger size wire is required for U S installations e Number 2 Phillips head screwdriver e Crimping tool must be large enough to accommodate the girth of the grounding lug when crimping the grounding cable into the lug e Wire stripping tool Step 1 Use a wire stripping tool to remove approximately 0 75 inch 19 mm of the covering from the end of the grounding wire Step2 Insert the stripped end of the grounding wire into the open end of the grounding lug Step3 Use the manufacturer recommended crimping tool to secure the grounding wire in place in the grounding lug Step4 Locate and remove the adhesive label from the system grounding pad on the chassis Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 a 4i7 Chapter 4 Installing the Cisco SCE8000 Chassis HZ installing the Power Supplies in the Cisco SCE8000 Chassis Figure 4 16 Installing the System Ground System
177. words for user admin and root level access These are authorization level passwords not individual passwords These passwords may be encrypted Passwords must meet the following criteria Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 OL 16478 02 _ Chapter 5 Connecting the Management Interfaces Minimum length 4 characters Maximum length 100 characters Begin with an alpha character May contain only printable characters The default password for all levels is cisco Initial Setup Parameters W System clock Current date and time The clock and the calendar must always be synchronized Time zone The name or ID of the time zone along with the number of hours offset from UTC Domain name server Default domain name which is used to complete unqualified host names as well as up to three domain name servers which are used for DNS lookup You must also enable DNS lookup RDR formatter destination The SCE platform generates Raw Data Records and sends them to the specified destinations external collection systems via the RDR formatter You can configure up to eight RDR formatter destinations Specify the IP address and port number for each destination The following table lists commands both for displaying the currently configured values and for configuring these parameters It also lists the command mode for each configuration command All show commands are executed from th
178. xposure to laser radiation and do not stare into open apertures A Warning This equipment must be grounded Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available A Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing Preventing Electrostatic Discharge Damage Electrostatic discharge ESD damage which can occur when electronic cards or components are improperly handled results in complete or intermittent failures Port adapters and processing modules consist of printed circuit boards that are fixed in metal carriers Electromagnetic interference EMI shielding and connectors are integral components of the carrier Although the metal carrier helps to protect the board from ESD use a preventive antistatic strap during handling Following are guidelines for preventing ESD damage e Always use an ESD wrist or ankle strap and ensure that it makes good skin contact e Connect the equipment end of the strap to an unfinished chassis surface e When installing a component use any available ejector levers or captive installation screws to properly seat the bus connectors in the backplane or midplane These devices prevent accidental removal provide proper grounding for
179. y downloading it from the server to the nonvolatile memory of the SCE8000 SCM E Tip When you install a new SCE8000 SCM E check the factory default configuration you might need to reconfigure the system to your requirements You can reconfigure the SCE8000 SCM E manually or if you previously uploaded the original configuration to a server you can download it to the new SCE8000 SCM E Cisco SCE8000 Installation and Configuration Guide Rel 3 1 7 oL 16478 02 g o7 Chapter9 Removal and Replacement Procedures HZ Removing and Replacing Modules Step 1 Step 2 amp At the SCE prompt type reload shutdown and press Enter to power down the Cisco SCE8000 platform before installing or removing any module Verify that the captive installation screws on all of the modules in the chassis are tight This step assures that the space created by the removed module is maintained Note Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 If the captive installation screws are loose the EMI gaskets on the installed modules will push the modules toward the open slot reducing the opening size and making it difficult to install the replacement module Disconnect all cables Loosen the two captive screws on the module Place your thumbs on the left and right ejector levers and simultaneously rotate the levers outward to unseat the module from the backplane connector Grasp the front edge of the module and slide