Contents
1. Hi Il ni s Mais Il Record Suffix Preamble Postamble Setting PROGRAM F DEFAULT Family Code Selection Parameter Selection Option Code STX ETX Control SS Disable STX ETX transmission 4 0 SS Enable STX ETX transmission 1 STX ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface Record Suffix SS None 0 SS CR 0DH 1 SS LF OAH 2 SS CRLF 0DOAH 3 SS TAB 09H 4 SS SPACE 20H 5 MS User defined character 1 character 6 00 7F Preamble SS None 9 FIN MS 1 15 characters 00 7F FIN il Il Maximum 15 character input scan FIN to terminate this selection Postamble SS None 9 FIN MS 1 15 characters 00 7F FIN Maximum 15 character input scan FIN to terminate this selection Serial Interface Message String RS232 USB COM STX Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble ETX Record Suffix 1 character 1 15 characters 2 3 digits Tor2 characters Variable length 1 or 2 characters 1 15 characters 1 character 1 character X S en c en Q kam a FuzzyScan 34 Configure Your FuzzyScan Serial Interface Control Ili Il Delay Setting PROGRAM F DEFAULT Family Code Selection LE L
2. Code 11 amp Code 93 Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Code 11 Setting SS Disable Code 11 amp 0 SS Enable Code 11 SS Disable check digit verification 2 SS Select 1 check digit verification 3 SS Select 2 check digit verification 4 SS Disable check digit transmission 4 5 SS Enable check digit transmission 6 Code 11 Min Length SS Default 04 amp FIN MS 01 Maximum 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically Code 11 Max Length SS Default 98 FIN MS 98 Minimum 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically qs Code 93 Setting SS Disable Code 93 0 SS Enable Code 93 1 gt SS Disable check digit transmission 4 2 bs SS Enable check digit transmission 3 ey Code 93 Min Length SS Default 01 FIN mam MS 01 Maximum 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate S this selection automatically i9 Code 93 Max Length SS Default 98 FIN N S MS 98 Minimum 2 digits Le on Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate N this selection automatically D Ly e 23 Configure Your Fuz
3. o Nu DE SPARE 0 P p Example 1 soH oct 1 A ala q If you want the scanned data output leading with a Dollar 2 STA Be f B i Sign you have to set the Preamble to The configuration EE 5 0 A S 9 oro s s procedure is listed below for reference 4 Etor Dc4 4 c RL d 5 ENQ NAK 5 E U e u Scan the system command PROGRAM listed on page eel ar ke A 3 7 V 3 24 to enter programming mode TE g W Scan family code PREAMBLE to select this family 8 Bs can 8 H X h Refer to the Hex ASCII Table you will find the HEX value 9 HT EM 9 Y i y of is 24 A LF sup J Z j z Scan the option code 2 listed on the fold out back cover B LUN Nox NU K C FF FS lt L l l Scan the option code 4 listed on the fold out back cover D cr Gs ii j Scan the system command FIN Finish to terminate E SO RS gt N i n Preamble setting F SI US o H 0 DEL Scan the system command End to exit the programming Example ASCII A HEX 41 ASCII a 61 mode for normal operation P 7 High Byte of HEX Value Low Byte of HEX Value X S en c en Q kam a FuzzyScan 55 Host Interface Quick Set RS232 Serial Keyboard Replacement X
4. Il FIN Finish PowerTool Host Link User Default END Factory Default Exit Programming Mode Master Default Factory Default After scanning Factory Default command all parameters will be returned to factory default value Master Default After scanning Master Default command the scanner will remain the pre set parameters of Host Interface Selection Keyboard Interface Control except Record Suffix Preamble Postamble Serial Interface Control except Record Suffix Preamble Postamble and Wand Laser Emulation Control the rest of parameters will be returned to default value User Default After scanning Save User Default command all current parameters will be stored to the flash memory Once you change the parameter and would like to return to previous setting please scan User Default X S ON c en Q kam a FuzzyScan 59 mA vww cine com tw FuzzyScan Family Programming Manual CINO GROUP PC WORTH INT L CO LTD C no
5. c en Q kam a FuzzyScan 35 Configure Your FuzzyScan Serial Interface Control Ili Protocol ACK NAK Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Handshaking Protocol SS None free running mode amp 0 SS RTS CTS hardware handshaking 1 SS ACK NAK software handshaking 2 SS Xon Xoff software handshaking 3 NAK Retry Count SS 3 times FIN SS 0 255 times 3 digits ACK Indication SS Disable ACK Time out Indication 0 SS Enable ACK Time out Indication 1 SS Disable ACK Indication 4 2 SS Enable ACK Indication 3 USB COM doesn t support RTS CTS handshaking protocol When the ACK NAK Software Handshaking option is selected the FuzzyScan waits for an ACK acknowledge or NAK not acknowledge from the host computer after each data transmission If the NAK is received FuzzyScan will re send the data until receiving ACK NAK Retry Count After transmitting data the scanner expects a NAK response from the host up to the preset Serial Response Time out If the scanner doesn t get a response the scanner will issue an error indication and discard the data When a NAK is received the scanner transmits the same data again and waits for either an ACK or NAK The scanner issues an error indication and discards th
6. Telepen Setting S c qd ON is B en A FuzzyScan 27 PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Telepen Setting SS Disable Telepen amp 0 SS Enable Telepen 1 SS Select Telepen Numeric mode 2 SS Select Telepen Full ASCII mode 3 SS Disable check digit transmission 4 4 SS Enable check digit transmission 5 Telepen Min Length SS Default 04 FIN MS 01 Maximum 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically Telepen Max Length SS Default 98 FIN MS 98 Minimum 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically Configure Your FuzzyScan GS1 DataBar Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code GS1 DataBar Setting SS Disable GS1 DataBar RSS 14 0 SS Enable GS1 DataBar RSS 14 1 SS Disable GS1 DataBar Limited 2 SS Enable GS1 DataBar Limited 3 SS Disable GS1 DataBar Expanded 4 SS Enable GS1 DataBar Expanded 5 GS1 DataBar Min Length SS Default 04 FIN MS 01 Maximum 2 digits Only available for Expanded GS1 Databar Scan 2 digits from the option code chart in Appendi
7. FuzzyScan X S en c en a Revision History Rev No Released Date Description Rev B Beta Apr 16 2009 First Release Page 22 Code 128 EAN 128 Setting Modify ISBT Concatenation Off option code to 4 Rev B May 05 2009 and ISBT Concatenation On option code to 5 Page25 GS1 Databar Setting All GS1 databar default values are changed to Enable Page 46 Add Symbology ID Table Rev B1 June 22 2009 Page 34 Add ETGSSnISHOR Scanning Mode Page 37 Add Time Delay to Low Power Mode Page9 11 Add PDF417 Micro PDF417 Codablock F Korea Post Code Page 26 Add Composite Code Setting PDF Micro PDF417 Setting Codablock F Setting Korea Post Code Setting Rev B2 Aug 21 2009 Page 39 Add SmartStand Power Off Timeout Page 46 Add PDF417 Micro PDF417 Codablock F Korea Post Code into Condensed DataWizard Table Page 48 Add PDF417 Micro PDF417 Codablock F Composite Code Korea Post Code IDs into Symbology ID Table Page8 Add IBM PS 2 25 30 series keyboard wedge interface Rev B3 Oct 16 2009 Page 39 Add Presentation Scanning Auto sense Page 48 Add Code 128 ID into Symbology ID Table Page 15 Modify UPC E EAN 8 expansion and UPC A standardization Page 33 Rename Time Out Control to Serial Response Time out Page35 Rename Presentation Scanning
8. SS Enable prefix CINO symbology ID transmission 1 SS Enable suffix CINO symbology ID transmission 2 SS Enable both prefix and suffix CINO symbology ID transmission 3 SS Enable prefix AIM symbology ID transmission 4 SS Enable suffix AIM symbology ID transmission 5 SS Enable both prefix and suffix AIM symbology ID transmission 6 X S en c en Q kam a FuzzyScan 10 FuzzyScan X S en c en Q kam a PROGRAM Family Code Selection Readable Symbology Setting Remember to scan FIN to terminate this selection But if you select the Auto FuzzyScan will terminate this selection automatically Configure Your FuzzyScan Symbology Reading Control Readable Bar Code Setting Parameter Selection Auto Code 128 UPC A UPC E EAN 13 EAN 8 Codabar NW 7 Code 39 Trioptic Code 39 Standard Industrial 2 of 5 Matrix 2 of 5 Interleaved 2 of 5 China Postal Code German Postal Code Code 93 Code 11 MSI Plessey UK Plessey Telepen GS1 DataBar RSS 14 IATA PDF417 Micro PDF417 Codablock F Korea Post Code F_DEFAULT Option Code f your application is known you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error Furthermore to add the Symbology ID into the transmitted data is also helpful to ident
9. host If you would like to remove the cable please straighten one end of a paper clip then insert it into the cable release hole to pull out the cable RS232 Serial Getting Started Using Accessories You can enhance productivity of your workforce by using various accessories to fulfill a wide variety of application demand Universal Holder A stylish Universal Holder is designed for storing your imager when not in use It serves to protect the imager from lens scratched or falling Moreover its artistic design enhances the entire value of the imager Hand free SmartStand A SmartStand is specifically designed for hand free applications to maximize user s comfort and productivity You can adjust the scanner holder to desired position for optimized scanning Thanks to the auto sense design the imager is capable of switching between presentation scanning and hand held scanning automatically while working with SmartStand amp Please note that the SmartStand is not applicable for FA00 Series imager X S en c en Q kam a FuzzyScan FuzzyScan X S en c en a Configure Your FuzzyScan Bar Code Programming Menu The FuzzyScan bar code commands are specially designed Proprietary bar code labels which allow you to set the FuzzyScan internal programming parameters There are System Command Family Code and Option Code for p
10. 128 0 SS Enable Code 128 and GS1 128 1 SS Disable function code conversion 4 2 SS Enable function code conversion 3 SS ISBT Concatenation Off 4 4 SS ISBT Concatenation On 5 Code 128 EAN 128 Min Length SS Default 01 FIN MS 01 Maximum 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically Code 128 EAN 128 Max Length SS Default 98 FIN 98 Minimum 2 digits PROGRAM Family Code Selection UK Plessey Setting Configure Your FuzzyScan Symbology Reading Control UK Plessey Setting Parameter Selection Disable UK Plessey 4 Enable UK Plessey Select UK Plessey Standard Format 4 Select UK Plessey CLSI Format Disable Convert X to A F 4 Enable Convert X to A F Disable check digit transmission 4 Enable check digit transmission F DEFAULT Option Code UK Plessey Min Length Default 04 01 Maximum Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically FIN 2 digits UK Plessey Max Length S c qd ON is B en A FuzzyScan Default 98 amp 98 Minimum Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically 26 FIN 2 digits Configure Your FuzzyScan Symbology Reading Control
11. Dollar sign output as 0 SS Dollar sign output as 1 SS Dollar sign output as 2 SS Dollar sign output as 3 SS Dollar sign output as 4 Redundancy SS None 0 SS Level1 1 SS Level 2 2 SS Level 3 3 SS Level 4 4 SS Level 5 5 To prevent potential miss reading Scan Rate Control SS Dynamic 0 X S en c en Q kam a FuzzyScan 41 Configure Your FuzzyScan Flash Duty Cycle Delay Setting PROGRAM F DEFAULT Family Code Selection Parameter Selection Option Code Flash Duty Cycle SS 1 2 duty cycle 0 SS 2 3 duty cycle 1 SS 3 4 duty cycle 2 SS 4 5 duty cycle 3 L680 L780 laser imagers don t support this function Reread Delay SS Disable 0 Double Scan Verification SS Immediate time out amp 1 SS Short time out 2 SS Medium time out 3 SS Long time out 4 SS Force verification 5 Good Read Delay SS None 9 0 SS 200 msec 1 SS 500 msec 2 SS 1 sec 3 SS 1 5 sec 4 SS 2sec 5 SS 3 sec 6 The Flash Duty Cycle is designed to control the flashing frequency of the light source The Reread Delay Double Scan Verification is designed to inhibit FuzzyScan from reading the same bar code label twice in pre defined short duration Force Verification will not allow reading of the same bar code twi
12. bar code Presentation Mode Auto Detection Presentation mode uses ambient light to detect the bar codes The light source is off until the scanner detects an image which is similar to a barcode Then the light source turns on automatically to read the bar code If the light level in the room is not high enough Presentation Mode may not work properly You can choose different level of Presentation Sensitivity to meet your application Please refer to the setting of Presentation Sensitivity Alternative Mode Periodic Power Off The scanner keeps the light source of the scanner turned on till the pre defined light source on time is up After the scanner turns off the light source you must press the trigger to turn on the light source again After each good read the timer counter of Light Source on Time is reset You do not have to press the trigger frequently it is very convenient for multiple scanning Flash Mode Pulse Driven Reading The scanner flashes the light source of the scanner without using the trigger If the scanner detects an image which is similar to a bar code the scanner forces on the light source automatically and scans the bar code Flash Duty Cycle adjustment can change the frequency of the blinking Force Mode Continued Power On The light source of the scanner is forced on for continued operation without pressing the trigger switch This mode is convenient for high speed bar code reading Toggle Mode Repe
13. check digit transmission as UPC E amp EAN 8 Expansion Expand the 8 digit UPC E and 8 digit ENA 8 to 12 digit UPC A and 13 digit EAN 13 UPC A Standardization Expand the 12 digit UPC A to 13 digit EAN 13 with 1 zero insertion UPC Lead 1 Numeric System Enable to read UPC leading with the 1 numeric system you must enable this option eas WPC Selection Basie Lenath Disable Disable With 2 digit With 5 digit Enable Enable om UPC EAN CAN g Check Digit Numeric System Addendum Addendum Standardization Expansion UPC A 12 1 1 2 5 1 0 UPC E 8 1 1 2 5 1 4 EAN 13 13 1 NC 2 5 NC 0 OQ EAN 8 8 1 NC 2 5 NC 5 N S gt i N 9f N D Ly e 16 Configure Your FuzzyScan Symbology Reading Control Ili Il UPC A amp UPC E Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code UPC Supplement Setting Select UPC without supplement digits 4 Select UPC with only 2 supplement digits Select UPC with only 5 supplement digits Select UPC with 2 5 supplement digits Disable force supplement digits output amp Enable force supplement digits output UPC Family Addenda Separator Off 4 UPC Family Addenda Separator On UPC EAN Security Level Level 0 Level 1 amp I du Only available for UPC A amp EAN 13 Supplement Scan Voting SS None Level 7 0 7 SS L
14. from the option code chart in Appendix then FuzzyScan will terminate z this selection automatically Code 39 Max Length SS Default 98 FIN R MS 98 Minimum 2 digits 73 e Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate D this selection automatically N ON Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously N D E eg 12 Configure Your FuzzyScan Symbology Reading Control Ili Code 39 Setting PROGRAM F DEFAULT Family Code Selection i Parameter Selection Option Code Code 39 Security Level SS Level 0 0 SS Level 1 1 SS Level2 2 SS Level 3 3 Code 39 Security Level The scanner offers four levels of decode security for Code39 bar codes Level 0 If you are experiencing misread of poorly printed or serious out of spec bar codes in level 1 please select level 0 Level 1 If you are experiencing misread of poorly printed or out of spec bar codes in level 2 please select level 1 Level 2 This is the default setting which allows the scanner to operate fastest while providing sufficient security in decoding in spec Code39 bar codes Level 3 If you failed to read poorly printed or out of spec bar codes in level 2 please select level 3 This is the most aggressive setting and may increase the misread X S en c en Q kam a FuzzyS
15. mode are available for FuzzyScan Laser model 39 Configure Your FuzzyScan Buzzer Indicator Vibrator Inverse Reading PROGRAM F_DEFAULT Buzzer Tone Adjust SS Buzzer tone mute 0 SS Buzzer tone low 1 SS Buzzer tone medium 4 2 SS Buzzer tone high 3 SS Buzzer tone extremely high 4 SS Power on beep 9 5 SS No power on beep 6 Power On Indicator SS Disable LED off 0 SS LED steady on 1 SS LED flash 2 Good Read Indicator SS Disable 0 ll un S Vibrator Control SS Disable 0 gt SS Enable 1 oN Il Optional function only available for vibrator model e Inverse Reading SS Disable 0 z I Ill I qe Sg N S gt N Of N D L e 40 Configure Your FuzzyScan The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted Scan Rate Control The scanner will have better motion tolerance when you select Fixed scan rate It s suitable for application which needs higher motion tolerance on the move But this may impact to the reading distance Dollar Sign Redundancy Scan Rate Controle PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Dollar Sign Control SS
16. to the host computers or terminals It allows you to select desired bar code symbologies for organizer control and provides maximum two identified positions to send the data forward or backward It also allows you to control the transmitted data including or excluding the data of identification position Please refer to the application example listed in page 45 for details While the Data Organizer is enabled it arranges only scanned data without Preamble Postamble STX ETX Data Length Prefix Suffix Symbology ID or Record Suffix Regarding the Bar Code Selection and Position Calculation of Data Organizer please refer to page 45 for details Please note that all Character input should be referred to the ASCII HEX Table X S ON c en Q kam a FuzzyScan 50 Configure Your FuzzyScan Select a Bar Code Symbology Data Verifier Data Replacer Data Organizer If there is a 11 character data string please refer to the following to calculate the actual position for identification You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement If you scan OO to select all types the X X X X X X X X X X X FuzzyScan will arrange all incoming data to meet your 00 01 02 03 04 05 06 07 08 09 10 pre defined format If you want to select only one type bar code please select one of the option code listed below Code 128 01
17. 2 supple E 1 EAN JAN 13 with 2 supple F E 1 UPC E with 5 supple 2 EAN JAN 13 with 5 supple 2 Example A UPC A bar code 012345678950 with 2 supplement 12 is Example A EAN JAN 8 bar code 49123562 with 5 supplement 12345 is Example A EAN 13 9923456789019 GS1 128 81010123451297 bar code is transmitted as E09923456789019 C181010123451297 transmitted as E0012345678950 E112 transmitted as E449123562 E212345 Code 128 Code 128 B C m Code 93 Code 93 H G m GS1 128 C 1 Code 11 Code 11 P H m Codabar Codabar NW 7 D F m MSl Plessey MSI Plessey R M m Standard Industrial 2 of 5 S 0 UK Plessey UK Plessey S P 0 Matrix 2 of 5 K X 0 Telepen Telepen T B m Code 25 Interleaved 2 of 5 J m GS1 et GS1 7 x China Postal Code L x 0 Composite Composite Code Code 39 G A m German Postal Code M 3 Code 39 Code 39 Trioptic W X 0 IATA IATA 0 R m Code 32 G A 0 UCC Coupon Code Z PDF417 PDF417 Micro PDF417 V L 0 Example A UPC A 512345678900 GS1 128 81010123451297 bar Codablock Codablock F Y 0 0 UCC Coupon code is transmitted as E0512345678900 C181010123451297 l Korea Post Korea Post Code S x 0 Remark Above examples are given for the transmission of AIM ID 53 Appendix Keyboard Function Code Table 00 NUL 00H RESERVED 16 DLE 10H F7 01 SOH 01H CTRL Left 17 DC1 1H F8 02 STX 02H A
18. BPS 2 8 SS 4800 BPS 115 2K BPS 3 9 Data Frame SS 8 None 1 amp 7 Space 1 0 8 SS 8 Odd 1 7 Mark 1 1 9 SS 8 Even 1 7 None 2 2 A SS 8 Space 1 7 Odd 2 3 B SS 8 Mark 1 T Even 2 4 C SS 8 None 2 7 Space 2 5 D SS 7 Odd 1 7 Mark 2 6 E SS T Even 1 7 When the RTS CTS Hardware Handshaking option is selected the RTS request to send and CTS clear to send signals will be issued before normal data communication This option is very helpful to ensure the reliability of data communication The Serial Response Time out is a pre defined delay time for FuzzyScan to wait for handshaking acknowledgment or non acknowledgment from the host computer X S en c en Q kam a FuzzyScan 37 Configure Your FuzzyScan Il Il heres c d Il Code 39 Code 128 Emulation PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection Option Code Code 39 Code 128 Emulation SS Disable standard Code 39 emulation 0 SS Enable standard Code 39 skip emulation 4 1 SS Enable standard Code 39 replace emulation 2 SS Enable Full ASCII Code 39 emulation 3 SS Enable Code 128 emulation 4 Code 39 Skip When this option is selected all scanned data will be translated as Standard Code 39 wand laser emulation output If any lower case characters are read they will be translated to upper case chara
19. E LC GC CE Option Code Intermessage Delay SS None 9 FIN Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate MS 1 99 x5 msec 2 digits this selection automatically Intercharacter Delay SS None 9 FIN I MS 1 99 x5 msec 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically Interfunction Delay SS None 9 FIN MS 1 99 x5 msec 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically Intermessage Delay is a time delay between messages output by FuzzyScan Increasing this delay will help host applications process the incoming data on time Intercharacter Delay is a time delay between data characters output by FuzzyScan These two parameters are used to synchronize data communication when 1 the data transmission speed is too fast characters may be skipped 2 multitasking operation system or host computers in a network may slow down the keyboard handling 3 various notebook or desktop PC systems require different timing parameter settings Please always add one extra unit as safety margin when adjusting these two parameters Interfunction Delay is a time delay between the transmission of each segment of the message string X S en
20. IN 2 digits identified position max 3 insertion characters position The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals It allows you to select desired bar code symbologies for formatter control and provides Multiple Position Insertion and Multiple Character Insertion max three characters in the identified position While the Data Formatter is enabled it arranges only scanned data without Preamble Postamble STX ETX Data Length Prefix Suffix Symbology ID or Record Suffix All of the above programmable parameters perform the same function depending on your setting Regarding the Bar Code Selection and Position Calculation of data formatter please refer to page 45 for details Please note that all Character input should be referred to the ASCII HEX Table listed in Appendix to find matched HEX value X S ON c en Q kam a FuzzyScan 47 Configure Your FuzzyScan Data Verifier Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Verifier Control SS Disable FIN MS Select one bar code symbology 2 digits automatic termination MS Select all bar code symbologies 00 auto
21. LT Left 18 DC2 12H F9 03 ETX 03H SHIFT 19 DC3 13H F10 04 EOT 04H CAPSLOCK 20 DC4 MH F1 05 ENQ 05H NUMLOCK 21 NAK 15H F12 06 ACK 06H ESC 22 SYN 16H INS Insert Edit 07 BEL o7H F1 23 ETB 17H DEL Delete Edit 08 BS 08H BACK SPACE 24 CAN 18H HOME Edit 09 HT 09H TAB 25 EM 19H END Edit 10 LF OAH F2 26 SUB 1AH PAGE UP Edit n VT OBH F3 27 ESC 1BH PAGE DOWN Edit 12 FF OCH F4 28 FS 1CH UP Edit I CR ODH ENTER CR 29 GS 1DH DOWN Edit 14 SO OEH F5 30 RS 1EH LEFT Edit 15 SI OFH F6 31 US 1FH RIGHT Edit amp To emulate the keyboard function key input for user definable parameters user must configure actual content using the Reserved ASCII 0 31 characters and also Enable the Function Key Emulation Otherwise the Ctrl output will be done by the scanner Please refer to the above Keyboard Function Code Table which is for IBM PC XT AT PS 2 PS VP COMPAQ PC HP Vectra PC Notebook PC APPLE and PowerMac and WYSE PC Enhanced or fully compatible machines S c qd ON is B en A FuzzyScan 54 Appendix ASCII Input Shortcut To configure the user definable parameters of FuzzyScan via HEX ASCII Reference Table programming menu FuzzyScan will ask you to scan your desired ASCII value in HEX form You have to refer to the HEX ASCII Table for details
22. Mode to Presentation Control Rev B4 Mar 05 2010 Page 38 Rename Auto Power Off Duration to Light Source On Time Add Extremely short option to Good Read Duration Page39 Rename Presentation Scanning Auto sense to Presentation Auto sense Add Presentation Sensitivity Page54 System Commands Add Master Default quick set command Rev B5 Apr 12 2010 Page38 Hands iion Time out Add DiSabIe f Page39 Add Trigger Control only available for FuzzyScan F460 F468 FuzzyScan X S en c en a Revision History Rev No Released Date Description Rev B6 May 27 2010 Page 33 Baud Rate Add 57 6K BPS and 115 2K BPS Page 17 Add UPC EAN Security Level Rev B7 Jun 25 2010 Page 38 Add Immediate parameter option 5 to Time Delay to Low Power Mode and change the default value from 5 seconds to immediate Page 15 16 Add Supplement Scan Voting Page 17 Add EAN Supplement Control Page 28 Keyboard Layout Add Czech QWERTY remove Universal and rename Rev B8 Sep 29 2010 Spain QWERTY to Spain Spanish QWERTY Latin America QWERTY to Spain Latin America QWERTY Page 37 Add Good Read Indicator Page 38 Scan Rate Control Rev B9 Nov 10 2010 Page 34 Baud Rate Cancel Baud Rate 300 600 BPS Rev C1 Mar 04 2011 Page 34 Baud Rate Revise 57 6K BP
23. S en c en Q kam a FuzzyScan Appendix PS 2 DOS V KBW Standard Mode PS 2 DOS V KBW Turbo Mode USB HID Standard Mode USB HID Turbo Mode USB Com Port Emulation 56 Appendix Operation Mode Quick Set Low Power Low power trigger ll TTT TTT a Trigger External triggering Il I Flash Pulse driven reading Presentation Auto sensing Level Auto power off FuzzyScan 57 X S en c en Q kam a Force Continued power on Toggle Repeat reading Diagnostic Test reading FuzzyScan S c qd ON is B en A Option Codes 1 2 3 0 ULL 4 ELI 5 ELLE 6 AL 7 FIN Finish Appendix 58 8 EU ELIT EU UI LU HU IA LULU F LULU END Exit Appendix System Commands PROGRAM System Information List Enter Programming Mode Il SYSLIST I Il
24. S and 115 2K BPS option code from 6 7 to 8 9 Page 13 Add Code 39 Security Level Rev C2 Mar 22 2011 Page 35 Add NAK Retry Count Add ACK NAK Transmission Indication Page 9 19 24 51 UCC EAN 128 was renamed GS1 128 Page 35 Add new parameters to ACK Indication Rev 22 2011 ES eevee Page 36 Modify Serial Response Time out parameters Page 44 Add Laser Aiming Control function Rev C4 Nov 04 2011 Page 14 Add Codabar Check Digit Settings Page 38 Wand Laser Emulation Control Cancel Output Polarity Initial Signal Rev C5 Jan 02 2012 State Margin Time Module Time and Narrow Wide Ratio Page 38 Code 39 Code 128 Emulation Change the default setting to option code 1 FuzzyScan X S en c en a Copyright Cino Group Copyright PC Worth Int l Co Ltd Cino makes no warranty of any kind with regard to this publication including but not limited to the implied warranty of merchantability and fitness for any particular purpose Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing performance or use of this publication This publication contains proprietary information that is protected by copyright All rights are reserved No part of this publication may be photocopied reproduced or translated into any language in any forms
25. Scan Family Code Selection Symbology Reading Control Ili Il Codabar NW 7 Setting PROGRAM F_DEFAULT Parameter Selection Option Code Codabar Max Length SS Default 98 amp FIN I Il MS 98 Minimum 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically FuzzyScan 15 X S ON c en Q kam a Configure Your FuzzyScan EN NLT Moecasveceseinn MANIN UPC A amp UPC E Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code UPC Family Setting SS Disable UPC A 0 SS Enable UPC A 1 SS Disable UPC E 2 SS Enable UPC E 3 SS Disable UPC E expansion 4 4 SS Enable UPC E expansion 5 SS Disable UPC standardization 6 SS Enable UPC standardization 7 SS Disable UPC numeric system 8 SS Enable UPC numeric system 4 9 SS Disable UPC A check digit transmission A SS Enable UPC A check digit transmission B SS Disable UPC E check digit transmission C SS Enable UPC E check digit transmission 4 D SS Disable UPC leading 1 portion 4 E SS Enable UPC leading 1 portion F When enable UPC E expansion the UPC E decoded data will be converted to UPC A format and affected by related setting such as UPC standardization UPC numeric system UPC A
26. UCC EAN 128 31 UPC A 02 UPC A with 2 supple 32 UPC A with 5 supple 42 UPC E 03 UPC E with 2 supple 33 UPC E with 5 supple 43 EAN 13 04 EAN 13 with 2 supple 34 EAN 13 with 5 supple 44 EAN 8 05 EAN 8 with 2 supple 35 EAN 8 with 5 supple 45 Codabar NW 7 06 Code 39 07 Code 32 37 Trioptic Code 39 47 Matrix 2 of 5 38 Interleaved 2 of 5 48 China Postal Code 58 German Postal Code 68 Code 93 09 Code 11 10 MSI Plessey 11 UK Plessey 12 Telepen 13 GS1 Data Bar 14 IATA 15 Coupon Code 16 PDF417 Micro PDF417 22 Codablock 23 Korea Post Code 26 Application Example If your bar code label is a 16 digit Interleaved 2 of 5 which includes the information of 6 digit date code 6 digit serial number and 4 digit unit price you want the FuzzyScan do the following for you without software modification Apply only Interleaved 2 of 5 to the condensed DataWizard Check bar code is actually with 16 digit length Allow bar code output whose date code is leading with 9 Position Calculation Three outputs with TAB suffix Data Formatter The date code output should skip 9 and replaced it by If there is a 5 character input data string refer to the following A to calculate the actual position for insertion The serial number output should be led with SN x A x x The unit price output should be s
27. a var mans MI mn User Defined Symbol ID PROGRAM F_DEFAULT Symbol ID 1 character Code 128 default B 1 character GS1 128 default C T 1 character UPC A default A 02 1 character EAN 13 default F 03 1 character Codabar NW 7 default D 04 1 character Code 39 Code 32 default G 05 1 character Code 93 default H 06 1 character Standard Industrial 2 of 5 default l 07 1 character Interleaved 2 of 5 default J 08 1 character Matrix 2 of 5 default K 09 1 character China Postal Code default L 10 1 character German Postal Code default M 11 1 character IATA default 0 12 1 character Code 11 default P 13 1 character MSI Plessey default R 14 1 character UK Plessey default S 15 1 character Telepen default T 16 1 character as GS1 DataBar default X 17 1 character gt UPC E default E 18 1 character EAN 8 default N 19 1 character on Trioptic Code 39 Default W 20 1 character UCC Coupon Extended Code Default Z 21 1 character r PDF417 Micro PDF417 default V 22 1 character Codablock F default Y 23 1 character Korea Post Code default a 26 1 character is E Configure Your FuzzyScan Symbology ID Transmission PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection Option Code Symbology ID Transmission SS Disable symbology ID transmission 0
28. an S c qd ON is B en A Configure Your FuzzyScan PROGRAM Symbology Reading Control Ili EAN Setting EAN Supplement Setting F DEFAULT Family Code Selection Parameter Selection Option Code EAN Setting SS Disable EAN 13 0 SS Enable EAN 13 1 SS Disable EAN 8 2 SS Enable EAN 8 3 SS Disable EAN 8 expansion 4 4 SS Enable EAN 8 expansion 5 SS Disable EAN 13 check digit transmission 6 SS Enable EAN 13 check digit transmission T SS Disable EAN 8 check digit transmission 8 SS Enable EAN 8 check digit transmission 4 9 SS Disable ISBN ISSN Conversion reading check 4 A SS Enable ISBN ISSN Conversion reading check B EAN Supplement Setting SS Select EAN without supplement digits 4 0 SS Select EAN with only 2 supplement digits 1 SS Select EAN with only 5 supplement digits 2 SS Select EAN with 2 5 supplement digits 3 SS Disable force supplement digits output amp 4 SS Enable force supplement digits output 5 SS EAN Addenda Separator Off 4 6 SS EAN Addenda Separator On 7 Supplement Scan Voting SS None Level 7 0 7 SS Level 1 Level 8 1 8 SS Level 2 Level 9 2 9 SS Level 3 4 Level 10 3 A SS Level 4 Level 11 4 B SS Level 5 Level 12 5 C SS Level 6 Level 13 6 D The Supplement Scan Voting is the number of times the same UPC EAN with 2 5 supplement digits has to be dec
29. an System List Group amp Master Default Cater FuzzyScan will list the product information and revision number to host via selected host interface then issue the completion beeping FuzzyScan will recover all programmable parameters into factory preset configurations then issue the completion beeping X S en c en Q kam a FuzzyScan Single scan selection Scan One of Family Codes Scan One of Option Codes Repeat Selection Configure Your FuzzyScan Enter programming mode Select one of desired programming families Select one option code of desired parameter Want to select another programming family Exit programming mode Multiple scans selection Scan One of Family Codes Scan One or Several Option Codes Repeat Selection Enter programming mode Select one of desired programming families Select one or several option codes to select desired parameters 2 If it s necessary scan FIN to terminate option code selection Want to select another programming family Exit programming mode Configure Your FuzzyScan Cycling scan selection Dual level selection Enter programming mode Select one of desired Scan One of Family Codes Scan One of Family Codes programming families Cycling select one or Scan several option codes of 1st Scan One of Option Codes desired parame
30. arcodes starting with digit 5 EAN 13 barcodes starting with digit 99 and GS1 128 Coupon Codes UPC A EAN 13 and EAN 128 must be enabled to scan all types of Coupon Codes X S ON c en Q kam a FuzzyScan 20 Configure Your FuzzyScan PROGRAM Symbology Reading Control Ili IATA amp Interleaved 2 of 5 Setting F DEFAULT Option Code Parameter Selection Family Code Selection S c qd ON is B en A FuzzyScan IATA Setting Disable IATA Enable IATA Select 15 digit fixed length IATA checking 4 2 Select variable length IATA 3 Disable check digit verification 4 4 Enable check digit automatic verification 5 Enable S N checking digit verification only 6 Enable CPN checking digit verification only 7 Enable CPN Airline and S N check digit verification 8 Disable check digit transmission 4 9 Enable check digit transmission A Disable start stop symbol transmission 4 B Enable start stop symbol transmission C Interleaved 2 of 5 Setting SS Disable Interleaved 2 of 5 0 SS Enable Interleaved 2 of 5 1 SS Select Interleaved 2 of 5 as primary format 2 SS Select German Postal Code as primary format 3 SS No check character 4 4 SS Validate USS check digit 5 SS Validate OPCC check digit 6 SS Disable check digit transmission 4 7 SS Enable check digit tra
31. at Reading The toggle mode is very similar to the Alternative Mode but without the pre defined light source on time concern You must press the trigger to turn on the light source of the scanner to scan The scanner keeps the light source turned on until you press the trigger again Diagnostic Mode Test Reading This operation mode is specifically designed for diagnostic purposes When this operation mode is selected the light source of the scanner is force on without regard for other programmable parameters such as reread delay redundancy and so forth Level Mode Auto Power Off When this operation mode is selected the scanner continues to turn on the light source of the scanner before a good read or pre defined Light Source on Time If the scanner decodes a bar code successfully it turns off the light source immediately After the scanner turns off the light source you must press the trigger to turn on the light source again If there is no scanning operation performed during the pre defined light source on time the scanner enters the idle state after the pre defined light source on time is up Presentation Control When the scanner is placed on SmartStand the scanner will be switched from hand held scanning to hands free scanning automatically Three hands scanning modes are available You are recommended to use flash mode or force mode while under insufficient ambient light Only Low power mode Trigger mode Presentation mode and Level
32. can 13 Configure Your FuzzyScan Symbology Reading Control Ili Il Codabar NW 7 Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Codabar Setting SS Disable Codabar li li SS Enable Codabar amp SS Select Codabar standard format 4 SS Select Codabar ABC format SS Select Codabar CLSI format SS Select Codabar CX format SS Disable start stop symbol transmission 4 SS Enable ABCD ABCD start stop symbol transmission SS Enable abcd abcd start stop symbol transmission SS Enable ABCD TN E start stop symbol transmission SS Enable abcd tn e start stop symbol transmission SS Disable check digit verification SS Enable check digit verification SS Disable check digit transmission 4 SS Enable check digit transmission Codabar Check Digit Settings SS Modulus 16 amp SS Modulus 10 weight 3 Codabar Min Length SS Default 04 FIN SS Modulus 10 weight 2 I WI MS 01 Maximum 2 digits SS 7 check DR SS Weight Modulus 11 SS Runes Modulus 10 weight 2 cci ND gt M O OO E gt J DAF ND Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically S c qd ON is B en A FuzzyScan 14 Configure Your Fuzzy
33. ce This Good Read Delay is the minimum amount of time before the imager can read another bar code X S ON c en Q kam a FuzzyScan 42 Configure Your FuzzyScan Time out Setting Good Read Duration PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Light Source On Time SS Short amp 0 SS Medium 1 SS Long 2 SS Extremely long 3 Hands Free Time out SS Short amp 0 SS Medium 1 SS Long 2 SS Extremely long 3 SS Disable 4 Good Read Duration SS Short 0 SS Medium 9 1 SS Long 2 SS Extremely long 3 SS Extremely short 4 Time Delay to Low Power Mode SS 1sec 0 SS 3secs 1 SS 5secs 2 SS 7 secs 3 SS 9 secs 4 SS Immediate amp 5 The Light Source On Time is a pre defined light source time out counter for Alternative Mode Presentation Mode and Level Mode The scanner keeps the light source on till the pre defined light source on time is up You can adjust this parameter to meet your own application requirement The Presentation Mode Force Mode and Flash Mode are referred to as hands free mode The hands free mode will be automatically changed to manual trigger mode when you press the trigger You can remain the scanner in manual trigger mode by setting the Hands Free Time Out Once the time
34. cters Any other characters that are not available in Code 39 symbology set will be skipped Code 39 Replace Any character not normally available in the standard Code 39 symbology set will be translated as Space X S ON c en Q kam a FuzzyScan 38 Configure Your FuzzyScan Operation Control Operation Mode Setting X S ON c en a FuzzyScan PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Operation Mode SS Low Power mode Force mode 0 5 SS Trigger mode 9 Toggle mode 1 6 SS Presentation mode Diagnostic mode 2 7 SS Alternative mode Level mode 3 8 SS Flash mode L680 L780 laser imagers don t support 4 Flash Force Toggle Diagnostic mode Presentation Control SS Presentation mode amp 0 SS Flash mode 1 SS Force mode 2 L680 L780 laser imagers don t support this function Low Power Mode Low Power Triggering The scanner goes into idle state after scanning the bar code You must press the trigger to wake up the scanner for operation It is very helpful for mobile data collection and application which are concerned with power saving Trigger Mode External Triggering The scanner goes into standby state after scanning the bar code You must press the trigger to turn on the light source of the scanner before scanning the
35. d matched HEX value X S en c en Q kam a FuzzyScan 48 FuzzyScan X S en c en Q kam a Configure Your FuzzyScan Data Replacer Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Replacer Control SS Disable FIN MS Select one bar code symbology 2 digits automatic termination MS Select all bar code symbologies 00 automatic termination 1st Replacement SS Disable 9 FIN DS Enable 2 digits 00 7F Il 2 digits identified position 1 replacement character position 2nd Replacement SS Disable 9 FIN DS Enable 2 digits 00 7F Il 2 digits identified position 1 replacement character position 3rd Replacement SS Disable FIN DS Enable 2 digits 00 7F Il Il 2 digits identified position 1 replacement character position The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals It allows you to select desired bar code symbologies for replacer control and provides Multiple Position Replacement in the identified position All data must conform to the Identified Bar Code Symbologies and one to three Identified Characters in the identified position While the Data Replacer is
36. e data under following two conditions 1 After preset NAK retry counts is received within the preset serial response time out 2 If the preset time out is up but the preset NAK retry counts haven t come to the end The default retry counts are three times If you program 0 time the scanner won t resend the data to the host when the scanner receives a NAK The scanner will discard the data If you program 255 times the scanner can receive unlimited NAKs from the host within the pre set serial response time out This function is not available for batch mode When you enable this function in on line mode the out of range function will be disable automatically ACK Indication Disable There s neither LED nor beeping indication for this setting Enable There s a specific LED and beeping indication for this setting X S ON c en a FuzzyScan 36 Configure Your FuzzyScan Il Il ad Men ka Il Time Out Setting Baud Rate Data Frame PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Serial Response Time out SS None 3 seconds 6 SS 200 mseconds 4 seconds 1 7 SS 500 mseconds 4 5 seconds 2 8 SS 800 mseconds 8 seconds 3 9 SS 1 second 10 seconds 4 A SS 2 seconds 15 seconds 5 B Baud Rate BPS SS 38 4K BPS 2400 BPS 0 4 SS 19 2K BPS 1200 BPS 1 5 SS 9600 BPS 9 57 6K
37. edures the family of the programming menu will be marked with the matched representing symbol of Programming Category P C in bold font listed in the following table You can easily find the bold mark in the programming menu and refer to their flowcharts for details Before setting the FuzzyScan please also refer to the Beeping Indications listed in Appendix to understand the details of programming beeping indications It will be very helpful for you to know the existing status while you are programming the FuzzyScan Conventions of Programming Menu Descriptions Factory Default Value P C Programming Category SS Single scan selection MS Multiple scans selection CS Cycling scan selection DS Dual level scan selection Necessary Option Code Selectable Option Code Program amp End Scan PROGRAM FuzzyScan will enter programming mode and inhibit all non programming functions FuzzyScan will exit programming mode and store all parameters in Flash Memory ASIC or non volatile memory then issue the completion beeping amp Please note that the FuzzyScan will take 3 4 seconds to store parameters in internal Flash Memory ASIC or non volatile memory after you scan the END Please don t turn off the power before the completion beeping It may destroy all configured parameters X S ON c en a FuzzyScan Configure Your FuzzySc
38. ement and DOS V Machines only 2 ON Caps Lock Release Control SS Caps Lock On Caps Off 0 en SS Caps Lock On Shift Off 1 F m cs FuzzyScan 31 Configure Your FuzzyScan Keyboard Interface Control Ili li Delay Setting PROGRAM F_DEFAULT Family Code Selection P Parameter Selection Option Code Intermessage Delay SS None FIN Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically Intercharacter Delay SS None 9 FIN I I MS 1 99 x5 msec 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically Interfunction Delay SS None FIN MS 1 99 x5 msec 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically Intermessage Delay is a time delay between messages output by FuzzyScan Increasing this delay will help host applications process the incoming data on time Intercharacter Delay is a time delay between data characters output by FuzzyScan These two parameters are used to synchronize data communication when 1 the data transmission speed is too fast characters may be skipped 2 multitasking operation system or host computers in a network may slow down the keyboard handling 3 various notebook or desktop PC systems require different ti
39. enabled it arranges only scanned data without Preamble Postamble STX ETX Data Length Prefix Suffix Symbology ID or Record Suffix Regarding the Bar Code Selection and Position Calculation of Data Replacer please refer to page 45 for details Please note that all Character input should be referred to the ASCII HEX Table listed in Appendix to find matched HEX value 49 Configure Your FuzzyScan Data Organizer Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Organizer Control SS Disable amp FIN MS Select one bar code symbology 2 digits automatic termination MS Select all bar code symbologies 00 automatic termination 1st Organization SS Disable amp FIN DS Enable 2 digits 0 Forward 9 2 digits identified position position 1 Backward Forward backward data transmission setting direction 2nd Organization SS Disable amp FIN DS Enable 2 digits 0 Forward 9 2 digits identified position position 1 Backward Forward backward data transmission setting direction Include Exclude Control SS Transmitted data excluded the data of identified position 4 0 DS Transmitted data included the data of identified position 1 The Data Organizer is used to edit the scanned raw data prior to transmitting the data
40. erminate this selection Postamble SS None FIN MS 1 15 characters 00 7F FIN Maximum 15 character input scan FIN to terminate this selection Data Length Transmission SS Disable 0 SS Enable 2 digits data length transmission 1 If data length exceeds 99 3 digit data length will be transmitted Symbology ID Transmission SS Disable symbology ID transmission 4 0 SS Enable prefix symbology ID transmission 1 SS Enable suffix symbology ID transmission 2 SS Enable both prefix and suffix symbology ID transmission 3 SS Enable prefix AIM symbology ID transmission 4 SS Enable suffix AIM symbology ID transmission 5 SS Enable both prefix and suffix AIM symbology ID transmission 6 DataWizard is the most powerful Artificial Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers Through DataWizard you can process the scanned data prior the transmissions in many ways as Insert Delete Match Verify Replace Reorganize and Repeat Transmission It will help you to arrange the transmission of scanned data to any specific format without software modification Due to the resources used by this system Full feature DataWizard is only supported by PowerTool Through the PowerTool all settings and configurations can be done on screen under Windows 95 98 NT 2000 XP environment A Condensed Version DataWizard is provided by each FuzzyScan series Thr
41. evel 1 Level 8 1 8 I SS Level2 Level 9 2 9 SS Level3 Level 10 3 A SS Level 4 Level 11 4 B SS Level 5 Level 12 5 C SS Level 6 Level 13 6 D UPC EAN Security Level The scanner offers three levels of decode security for UPC EAN bar codes Level 0 If you are experiencing misread of poorly printed or out of spec bar codes especially in characters 1 2 7 and 8 in level 1 please select level 0 Selection of this security level may significantly impair the decoding ability of the scanner Level 1 This is the default setting which allows the scanner to operate fastest while providing sufficient security in decoding in spec UPC EAN bar codes Level 2 If you are experiencing misread of poorly printed soiled or damage bar codes in level 1 please select level 2 This is the most aggressive setting and may increase the misread The Supplement Scan Voting is the number of times the same UPC EAN with 2 5 supplement digits has to be decoded before it is transmitted It is helpful when decoding a mix of UPC EAN symbols with and without supplement digits This function is effective when you select UPC EAN with only 2 supplement digits UPC EAN with only 5 supplement digits or UPC EAN with 2 5 supplement digits The default value is Level 3 When you select higher level it may impact the reading speed on poorly printed low contrast or damage barcode labels X S ON c en Q kam a FuzzyScan 17 FuzzySc
42. ify the specific symbology Above symbologies marketed with are enable as default When you select Auto the imager only read those symbologies marked with When you set the minimum and maximum length of each symbology please note the data length of scanned bar code doesn t include star stop characters Configure Your FuzzyScan Code 39 Code 32 Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Code 39 Family Setting SS Disable Code 39 0 SS Enable Code 39 1 SS Select Standard Code 39 as primary format 4 2 SS Select Full ASCII Code 39 as primary format 3 SS Select Code 32 PARAF Italian Pharmaceutical as primary format 4 SS Disable start stop symbol transmission 4 5 SS Enable start stop symbol transmission 6 SS Disable Code 32 leading A transmission 4 T SS Enable Code 32 leading A transmission 8 SS Disable MOD 43 check digit verification 9 SS Enable MOD 43 check digit verification A SS Disable check digit transmission 4 B SS Enable check digit transmission C SS Disable Code 39 buffering D e SS Enable Code 39 buffering E Trioptic Code 39 Setting SS Disable Trioptic Code 39 0 SS Enable Trioptic Code 39 1 gt UL Code 39 Min Length SS Default 01 FIN en MS 01 Maximum 2 digits Y Il Scan 2 digits
43. in an electronic retrieval system or otherwise without prior written permission of Cino All product information and specifications shown in this document may be changed without prior notice Warranty Cino warrants its products against defects in workmanship and materials from the date of shipment provided that the product is operated under normal and proper conditions The warranty provisions and durations are furnished by different warranty programs The above warranty does not apply to any product which has been i misused ii damaged by accident or negligence iii modified or altered by the purchaser or other party iv repaired or tampered by unauthorized representatives v operated or stored beyond the specified operational and environmental parameters vi applied software accessories or parts are not supplied by Cino vii damaged by circumstances out of Cino s control such as but not limited to lightning or fluctuation in electrical power Any defective product must follow the warranty program and RMA procedures to return Cino for inspection Regulatory FC FCC part 15B CE EN55022 EN55024 EN61000 3 2 EN61000 3 3 EN60950 1 EN61000 6 3 EN61000 6 2 G CNS13438 AS NZS CISPR 22 2009 Class B KN22 KN24 KN61000 2 3 4 5 6 8 11 LED Eye Safety IEC62471 Exempt group Laser Eye Safety IEC60825 1 Class 1 X S en c en Q v a FuzzyScan Table of Contents Getting Started Get
44. kipped the first 2 00 01 02 03 04 05 digits Test Bar Code 9810251234569876 Actual Output A81025 TAB SN123456 TAB 76 TAB X S en c en a FuzzyScan 51 X S en c en a FuzzyScan Configure Your FuzzyScan Programming Procedure Data Verifier Scan Program to enter the programming mode Scan Verifier Control and set bar code symbology to 48 Interleaved 2 of 5 Scan Identified Data Length and set the length to 16 Scan ist Identified Character and set the identified position to 00 then set the identified character to 39 Hex Code of 9 Data Formatter Scan Formatter Control and set bar code symbology to 48 Scan 1st Insertion and set the identified position to 06 then inserted characters to 09 Hex Code of TAB 53 Hex Code of S 4E Hex Code of N Scan 2nd Insertion and set the identified position to 12 then inserted character to 09 In the final you must scan FIN Finish code to terminate this selection Scan 3rd Insertion and set the identified position to 16 then inserted character to 09 In the final you must scan FIN Finish code to terminate this selection Data Replacer Scan Replacer Control and set bar code symbology to 48 Scan 1st Replacement a
45. llows the scanner to operate fastest while providing sufficient security in decoding in spec UPC EAN bar codes Level 2 If you are experiencing misread of poorly printed soiled or damage bar codes in level 1 please select level 2 This is the most aggressive setting and may increase the misread EAN Supplement Control If you select EAN with only 2 or 5 or 2 5 supplement digits and enable 491 prefix supplement digit output the scanner will transmit EAN with 2 or 5 or 2 5 supplement digits bar codes starting with 491 prefix The EAN without supplement digit will not be transmitted If you select EAN with only 2 or 5 or 2 5 supplement digits and enable the other except 491 prefix supplement digit output the scanner will transmit EAN with 2 or 5 or 2 5 supplement digits bar codes starting with specific prefix The EAN without supplement digit will be transmitted SS Enable 491 Supplement Digit Output NOOO amp ND X S ON c en a FuzzyScan 19 Configure Your FuzzyScan ELLE LU ce coupon exons cou Seing MIT IT UCC Coupon Extended Code Setting PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection Option Code UCC Coupon Extended Code SS Disable UCC Coupon Extended Code 0 SS Enable UCC Coupon Extended Code 1 UCC Coupon Extended Code When UCC coupon extended code function is enabled scanner decodes UPC A b
46. matic termination Identified Data Length SS Disable amp FIN DS Enable 2 digits Determine the identified data length for verification 1st Identified Character SS Disable amp FIN DS Enable 2 digits 00 7F 2 digits checking position 1 identified character position 2nd Identified Character SS Disable amp FIN DS Enable 2 digits 00 7F 2 digits checking position 1 identified character position 3rd Identified Character SS Disable FIN DS Enable 2 digits 00 7F Il 2 digits checking position 1 identified character position The Data Verifier is used to provide advanced verification for error free scanning and to work as an Embedded Data Transmitting Filter All data must conform to the Identified Bar Code Symbologies Identified Data Length and one to three Identified Characters in the checking position Otherwise the FuzzyScan will not transmit the data to the host computers or terminals but will instead issue 3 long beeps for verification error and skip the scanned data The Data Verifier checks only scanned data without Preamble Postamble STX ETX Data Length Prefix Suffix Symbology ID or Record Suffix Regarding the Bar Code Selection and Position Calculation of Data Verifier please refer to page 45 for details Please note that all Character input should be referred to the ASCII HEX Table listed in Appendix to fin
47. ming parameter settings Please always add one extra unit as safety margin when adjusting these two parameters Interfunction Delay is a time delay between the transmission of each segment of the message string MS 1 99 x5 msec 2 digits X S en c en Q kam a FuzzyScan 32 Configure Your FuzzyScan I Il i dde ee I Emulation Setting amp Upper Lower Case Setting PROGRAM F DEFAULT Family Code Selection Parameter Selection Option Code Function Key Emulation SS Enable ASCII 00 31 code as keyboard function code output amp 0 SS Ctrl Output 1 Refer to Appendix Keyboard Function Code Table for details Key Pad Emulation SS Disable key pad emulation amp 0 li SS Enable numeric output as key pad Num Lock On output 1 Upper Lower Case SS Normal case neglect the upper lower case control amp 0 SS Inverse case change all characters output to inverse case 1 SS Upper case force all characters output as upper case 2 SS Lower case force all characters output as lower case 3 X S ON c en Q kam a FuzzyScan 33 Configure Your FuzzyScan
48. nd set the identified position to 00 then replaced character to 41 Hex Code of A Data Organizer Scan Organizer Control and set bar code symbology to 48 Scan 1st Organization and set the identified position to 16 then set the data transmission to 0 forward Scan 2nd Organization and set the identified position to 17 then set the data transmission to 1 backward Scan END Exit to terminate the programming Important Notice Please note that Condensed DataWizard will follow the preset working flow as below Verifier Formatter Replacer Organizer So when you set the identified position in Data Organizer you must consider the inserted data which you already set via Data Formatter FuzzyScan X S en c en Q kam a Symbology ID Table Each AIM Code Identifier contains the three character string Jcm where Flag Character c Code Character m Modifier Character Appendix Cino ID AIM ID Cino ID AIM ID Code Family Primary Format Code Code Modified Code Family Primary Format Code Code Modified Character Character Character Character Character Character UPC A m EAN JAN 8 4 UPC A with 2 supple A 1 EAN JAN 8 with 2 supple N E 1 UPC A with 5 supple E 2 EAN JAN 8 with 5 supple 2 UPC UPC E m EAN JAN EAN JAN 13 m UPC E with
49. ning and the light source will be forced on automatically The light source will be off when the pre defined duration is up When enable the Presentation Auto sense the scanner can be switched between hands free scanning and hand held scanning automatically when working with the SmartStand The presentation sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode The higher lever means higher sensitivity for detecting the barcode X S ON c en Q kam a FuzzyScan 44 Configure Your FuzzyScan Operation Control Laser Aiming Controle Only available for L series laser imaging scanner PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection Option Code Laser Aiming Control SS Disable 0 SS Enable 4 X S en c en Q kam a FuzzyScan You can disable or enable laser aiming line when you scan PDF barcode 45 PROGRAM Configure Your FuzzyScan Condensed DataWizard Preamble Postamble Data Length amp Symbol ID Trans Parameter Selection F_DEFAULT Family Code Selection Option Code Preamble SS None FIN MS 1 15 characters 00 7F FIN Il Maximum 15 character input scan FIN to t
50. nsmission 8 21 Configure Your FuzzyScan Code 25 Family Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Code 25 Setting SS Disable Standard Industrial 2 of 5 0 SS Enable Standard Industrial 2 of 5 1 SS Disable Matrix 2 of 5 2 SS Enable Matrix 2 of 5 3 SS Disable China Postal Code 4 SS Enable China Postal Code 5 SS Disable check digit verification 6 SS Enable check digit verification T SS Disable check digit transmission 4 8 SS Enable check digit transmission 9 Code 25 Family Min Length SS Default 04 FIN MS 01 Maximum 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically Code 25 Family Max Length SS Default 98 FIN MS 98 Minimum 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically For Code25 setting we recommend you to select only one type of Code 25 or set the maximum minimum bar code length To decode all types of Code 25 or to variable length of Code 25 will increase the possibility of reading error S c qd ON is B en A FuzzyScan 22 Configure Your FuzzyScan
51. oded before it is transmitted It is helpful when decoding a mix of UPC EAN symbols with and without supplement digits This function is effective when you select UPC EAN with only 2 supplement digits UPC EAN with only 5 supplement digits or UPC EAN with 2 5 supplement digits The default value is Level 3 When you select higher level it may impact the reading speed on poorly printed low contrast or damage barcode labels 18 Configure Your FuzzyScan EAN Security Level Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code UPC EAN Security Level SS Level 0 0 SS Level1 1 Only available for UPC A amp EAN 13 EAN Supplement Control SS Disable all specific prefix supplement digital output amp SS Enable all specific prefix supplement digital output SS Enable 978 979 Supplement Digit Output SS Enable 977 Supplement Digit Output SS Enable 378 379 Supplement Digit Output SS Enable 414 419 Supplement Digit Output SS Enable 434 439 Supplement Digit Output UPC EAN Security Level The scanner offers three levels of decode security for UPC EAN bar codes Level 0 If you are experiencing misread of poorly printed or out of spec bar codes especially in characters 1 2 7 and 8 in level 1 please select level 0 Selection of this security level may significantly impair the decoding ability of the scanner Level 1 This is the default setting which a
52. ough this menu the condensed DataWizard can be utilized via bar code menu readings with ease Please note that all Character input should be referred to the ASCII HEX Table listed in Appendix to find matched HEX value f you have any problem to use DataWizard please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance X S ON c en a FuzzyScan 46 Configure Your FuzzyScan Data Formatter Setting PROGRAM F_DEFAULT Family Code Selection P C Parameter Selection _ Option Code 2nd Option Code l Formatter Control SS Disable FIN MS Select one bar code symbology 2 digits automatic termination Il MS Select all bar code symbologies 00 automatic termination 1st Insertion SS Disable 9 FIN DS Enable 2 digits 1 3 characters FIN 2 digits identified position max 3 insertion characters position 2nd Insertion SS Disable 9 FIN DS Enable 2 digits 1 3 characters FIN 2 digits identified position max 3 insertion characters position 3rd Insertion SS Disable FIN DS Enable 2 digits 1 3 characters FIN 2 digits identified position max 3 insertion characters position Ath Insertion SS Disable amp FIN DS Enable 2 digits 1 3 characters F
53. out duration is up if there s no any trigger operation the imager will revert to the original hands free mode The Time Delay to Low Power Mode sets the time for scanner to enter low power mode after any scanning activity This setting is only available for the scanner is in low power mode X S en c en Q kam a FuzzyScan 43 Configure Your FuzzyScan Il Il paio ipid Il Presentation Scanning Setting Trigger Controle PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code SmartStand Power Off Timeout SS 3mins 0 SS 5mins 1 Il SS 10 mins 2 Only available for FuuzzyScan Laser model Presentation Auto sense SS Disable 0 SS Enable 9 1 Presentation Sensitivity SS Level 1 Level 6 0 5 SS Level 2 Level 7 1 6 SS Level 3 2 SS Level 4 3 SS Levelb 4 Trigger Control SS Enable left trigger disable right trigger 0 SS Enable right trigger disable left trigger 1 i SS Enable left and right triggers 2 Only available for FuzzyScan F460 F468 The SmartStand Power Off Timeout is a pre defined duration for scanner s light source on time when the scanner is placed on SmartStand While the scanner is placed on SmartStand the scanner s will be switched from hand held scanning to presentation scan
54. rogramming purpose Each programmable family and bar code command label is listed on the same page with major system commands The detailed explanations and special programming flowchart are printed on facing or following pages You can read the explanation and set the FuzzyScan concurrently A supplemental bar code command menu incorporates the bar code command labels of System Command and Option Code As you set the FuzzyScan open the bar code command menu to find the option code page You may scan the desired family code and option code to set FuzzyScan If you want to change the programming family for multiple settings you need only turn over the programming page to find next desired programming family System Command The System Command is the highest level bar code command which directs FuzzyScan to perform immediate operations such as entering programming mode PROGRAM exiting programming mode EXIT listing system information SYSLIST recovering to factory preset configurations M DEFAULT and so on Please note that all system commands will take a few seconds to complete the operations User must wait for the completion beeps before scanning another bar code Family Code The Family Code is scanned to select the user desired programming family FuzzyScan has already provided more than one hundred programming families to meet any specific requirements Option Code The Option Codes is a set of bar code commands repre
55. sented by 0 9 A F and finishing selection FIN For most setting you must select at least one option code following the family code selection to set the desired parameter for the selected programming family FuzzyScan X S en c en a Configure Your FuzzyScan Programming Procedures As you scan the bar code command to select the desired parameters information about the final selected parameters represented by the bar code commands are stored in the FuzzyScan s internal Flash Memory ASIC or non volatile memory If you turn off the unit the Flash Memory ASIC or non volatile memory retains all programming options You need not re program the FuzzyScan if you want to keep the existing configurations in the next power on The programming procedures of FuzzyScan are designed as simple as possible for ease of setting Most programming families take the Single Scan Selection programming procedure But several programming families have more complex and flexible programmable options and you must take Multiple Scans Selection Cycling Scan Selection or Dual Level Selection to complete their programming procedures Each kind of programming procedure is listed in the following pages for your reference Please give careful attention to become familiar with each programming procedure f the programming family must take multiple scans selection cycling scan selection or dual level selection proc
56. ters as Several Option Codes Single or Multiple scans selection 2nd Scan One or Several Option Codes Scan FIN Finish cycling selection If necessary Repeat Selection Repeat Want to select another Selection programming family Exit programming mode X S ON c en Q kam a FuzzyScan Enter programming mode Select one of desired programming families Select several option codes of desired parameters 1 Select one or several option codes of desired parameters 2 If it s necessary scan FIN to terminate option code selection Want to select another programming family Exit programming mode PROGRAM Family Code Selection Host Interface Selection X S en c en Q kam a FuzzyScan Configure Your FuzzyScan Host Interface Selection Parameter Selection IBM PS 2 25 30 series keyboard wedge interface Standard TTL RS 232 peer to peer serial Wand emulation USB Com Port Emulation PS 2 DOS V direct link keyboard replacement PS 2 DOS V keyboard wedge turbo mode PS 2 DOS V keyboard wedge standard mode Laser emulation USB HID standard mode USB HID turbo mode F_DEFAULT Option Code Configure Your FuzzyScan S Q un D N N se Mi il L
57. ting Familiar with Your FuzzyScan Connecting to Your Host Using Accessories Configure Your FuzzyScan Bar Code Programming Manual Programming Procedures Host Interface Selection Symbology Reading Control Keyboard Interface Control Serial Interface Control Wand Laser Emulation Control Operation Control Condensed DataWizard Appendix Symbology ID Table Keyboard Function Code Table ASCII Input Shortcut Host Interface Quick Set Operation Mode Quick Set Option Codes System Commands X S en c en Q kam a FuzzyScan 48 49 50 51 52 53 54 FuzzyScan X S ON c en Q kam a Getting Started Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan Imager All FuzzyScan imagers deliver world class performance for a broad range of applications to unleash your productivity This document provides an easy reference for installation and operation purposes A complete documentation is provided by the FuzzyScan Programming Manual available at www cino com tw F700 amp L700 Series Power Indicator Status Indicator Trigger Scan Window 6 Beeper Cable Release Hole F400 Series Connecting to Your Host FuzzyScan imagers support PS 2 DOS V Keyboard Wedge RS 232 Serial and USB interfaces Please choose your desired interface cable then plug it into the cable interface port of the imager and connect it to the
58. ur FuzzyScan Keyboard Interface Control The function of Caps Lock Control and Key Pad Emulation are only available for IBM PC AT PS VP PS 2 series personal computers and compatible machines While selecting the other host interfaces these selections don t perform the above functions for you Please check the actual Caps Lock state in use while software application is running If the Caps Lock state is off select Caps Lock Off state then FuzzyScan will perform normal data transmission If the Caps Lock state is on select Caps Lock On state Select Auto Detect FuzzyScan will perform special transmission handshaking without changing the status of Caps Lock switch PROGRAM F DEFAULT Family Code Selection Parameter Selection Option Code Record Suffix SS None 0 SS RETURN 1 SS TAB 2 SS SPACE 3 SS ENTER Numeric Key Pad 4 SS User defined character 1 character 5 00 7F Preamble SS None 9 FIN MS 1 15 characters 00 7F FIN Il Maximum 15 character input scan FIN to terminate this selection Postamble SS None 9 FIN MS 1 15 characters 00 7F FIN Maximum 15 character input scan FIN to terminate this selection e Caps Lock Control SS Caps Lock Off State 0 e SS Caps Lock On State 1 gt SS Auto Detect PC AT PS 2 Keyboard Replac
59. x then FuzzyScan will terminate this selection automatically GS1 DataBar Max Length SS Default 74 amp FIN MS 74 Minimum 2 digits Only available for Expanded GS1 Databar Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically S c qd ON is B en A FuzzyScan 28 Configure Your FuzzyScan Il Il nt ia ua Il Linear stacked amp Korea Post Code Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Composite Codes Setting SS Disable composite codes 4 0 SS Enable composite codes 1 SS UPC Composite Mode UPC never linked 4 2 SS UPC Composite Mode UPC always linked 3 PDF417 Micro PDF417 Setting SS Disable PDF417 0 SS Enable PDF417 1 SS Disable MicroPDF417 2 SS Enable MicroPDF417 3 Codablock F Setting SS Disable 0 M SS Enable 1 Korea Post Code Setting SS Disable 0 SS Enable 1 Composite Codes Setting If UPC Composite Mode UPC never linked is selected UPC barcodes are transmitted regardless of whether a MicroPDF417 symbol is detected If UPC Composite Mode UPC always linked is selected UPC barcodes are only transmitted when the MicroPDF417 is detected Length fi
60. xed in 6 characters X S ON c en Q kam a FuzzyScan 29 FuzzyScan X S ON c en Q kam a PROGRAM Family Code Selection Keyboard Layout Configure Your FuzzyScan Keyboard Interface Control Keyboard Layout Language Setting Parameter Selection USA QWERTY France AZERTY Germany QWERTZ United Kingdom UK QWERTY Canadian French QWERTY Spain Spanish QWERTY Sweden Finland QWERTY Portugal QWERTY Norway QWERTY Spain Latin America QWERTY Italy QWERTY Netherlands QWERTY Denmark QWERTY Belgium AZERTY Switzerland Germany QWERTY Iceland QWERTY Japan DOS V Czech QWERTY F_DEFAULT Option Code Please refer to the ASCII HEX Table listed in the Appendix to determine HEX codes for characters symbols and functions to be used as preamble or postamble To set preamble or postamble as function key output you must enable the Function Key Emulation feature as listed in page 3 25 first Keyboard Interface Message String Preamble Data Length 1 15 characters 2 3 digits Prefix Symbol ID 1 or 2 characters Scanned Data Variable length 1 or 2 characters 30 Suffix Symbol ID Postamble 1 15 characters Record Suffix 1 character Record Suffix Preamble Postamble amp Caps Lock Configure Yo
61. zyScan Symbology Reading Control MSI Plessey Setting S c qd ON is B en A FuzzyScan 24 PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code MSI Plessey Setting SS Disable MSI Plessy amp 0 SS Enable MSI Plessy 1 SS Select MOD 10 check digit amp 2 SS Select MOD 10 10 check digit 3 SS Select MOD 11 10 check digit 4 SS Disable check digit transmission 4 5 SS Enable check digit transmission 6 MSI Plessey Min Length SS Default 04 FIN MS 01 Maximum 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically MSI Plessey Max Length SS Default 98 FIN MS 98 Minimum 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically Configure Your FuzzyScan Symbology Reading Control Code 128 amp UCC EAN 128 Setting i S c qd ON is B en A FuzzyScan Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically 25 PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Code 128 EAN 128 Setting SS Disable Code 128 and GS1
Download Pdf Manuals
Related Search
Related Contents
Samsung AS10FLNXSB คู่มือการใช้งาน Samsung MX-J630 Manual de Usuario Blow up - Lycéens et apprentis au cinéma Press to press remote control user manual: 1) The press to press RC REPLACEMENT HOSE AND ADAPTOR Cornelius Connector J18 User's Manual 9122012 Luna Sat B60 コンパクトEHA Mechanical details Copyright © All rights reserved.