Home

Chief Manufacturing TV Mount JWP-V User's Manual

image

Contents

1. 81 77 3 22 O Q sels 7 A 1 120 65 175 87 ae 6 92 8 7 14 4X Q 28 0oe8 0 o QO Installation Instructions CONTENTS DIMENSIONAL DRAWING oreren 2 TOOLS REQUIRED FOR INSTALLATION 3 INSPECT UNIT BEFORE INSTALLING 0000000 3 SPECIFICATIONS oniinn nan eaae 3 INTRODUCTION erer errore erore eree ETEA 4 PARTS n e OOO 5 PARTS Continued eeeeeseeeeeeeseeseseeseessresrsseseeses 6 SECURE WALL BRACKET 7 INSTALLATION Wu cece ccc cece ceseseceseseessesenenees J 100mm x 100mm Flush and Recessed Mount Installati n neriie elie 7 Flush Mount Installation ou eee 7 Recess Mount Installation cc ccc ceeseeeees 8 Interface Bracket Installation 9 200mm x 100mm Pattern 10 300mm x 100mm Pattern 10 300mm x 200mm Pattern 11 400mm x 200mm Patter eee 11 200mm x 200mm Pattern 12 Attach Display to Mount Centris Bracket 13 ATTACH MOUNT TO WALL BRACKET 13 CABLE MANAGEMENT oseere 14 ADJUSTMENTS oe cece an aana 14 Lateral Tension Adjustment ceeeeeeeeeees 14 Pitch Tension Adjustment eceeceeseeeeeneees 14 JWP V TOOLS REQUIRED FOR INSTALLATION e Electric drill and bit set e Hex wrench set e Phillips screwdriver e Level NOTE Other tools may be required depending on your display JWP configuration and method of installation INSPE
2. 100mm x 100mm Figure 1 Typical VESA Mounting Hole configurations Installation Instructions JWP V PARTS Centris Bracket aan See notes BAG A BAG B BAGD t gt fF gt BAG E gt gt He c Figure 2 JWP V Components Installation Instructions PARTS Continued Table 2 shows the individual part and parts bags shipped with JWP parts Item 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 180 190 200 Table 2 JWP Parts List Description MSP MA MOUNT with Centris bracket Interface Bracket Wall Bracket Lag Screws 3 8 x 3 Phillips Head Cap Screw M4 X 12mm Phillips Flat Head Machine Screw M4 X 16mm Phillips Head Cap Screw M4 X 20mm Phillips Head Cap Screw M4 X 8mm Phillips Head Cap Screw M6 X 20mm Phillips Head Cap Screw M6 X 30mm Phillips Head Cap Screw M6 X 45mm Nylon Spacer 75 x 25 x 25 Nylon Spacer 625 x 194 x 125 Hex Key 5 32 Hex Key 3 16 Phillips Head Cap Screw M5 X 20mm Phillips Head Cap Screw M5 X 30mm Phillips Head Cap Screw M5 X 45mm Qty AJAJIA JWP V Notes Use with 40 Use with 30 No spacers needed for 100mm x 100mm flush mounted Centris bracket For 200mm x 100mm and 300mm x 100mm For 100mm x 100mm recess mounted Centris bracket Use with 120 Used to mount display with Interface bracket to Centris bracket For 300mm x 200mm and 400mm x 200mm U
3. 2 Attach the interface bracket 20 using the hole pattern on the back of your display as shown in Figure 7 3 Tighten each screw To prevent equipment damage do not over tighten the screws 400mm x 200mm Pattern For the 400mm x 200mm hole pattern do the following 1 Select six Phillips head M6 screws 90 from Bag B and six spacers 120 from Bag C 2 Attach the interface bracket 20 using the hole pattern on the back of your display as shown in Figure 8 3 Tighten each screw To prevent equipment damage do not over tighten the screws JWP V ATTACH BRACKET TO BACK OF DISPLAY USING M SCREWS BAG B AND THESE HOLES AN JIN E E Figure 7 Display with 300mm x 200mm Hole Pattern ATTACH BRACKET TO BACK OF DISPLAY USING M6 SCREWS BAG B AND THESE HOLES MN i o i o x Jor obvoeo Figure 8 Display with 400mm x 200mm Hole Pattern 11 Installation Instructions 200mm x 200mm Pattern For the 200mm x 200mm hole pattern do the following 1 12 Select the applicable screws as follows a If using square hole on interface bracket 20 select four Phillips head M4 screws from Bag A OR b If using round hole on interface bracket 20 sele
4. INSTALLATION INSTRUCTIONS Medium Flat Panel Pivot Pitch Wall Mount Model JWP V The JWP Pivot Pitch wall mount is designed for mounting a medium sized flat panel display The mount can be tilted up and down to 15 of center as well as pivot left and right The JWP is shipped with the VESA 100mm 100mm Centris interface which is compatible with most medium flat panels To accommodate other mounting patterns in displays the JWP comes with a VESA Plate that accommodates other VESA mounting patterns By design the JWP can be configured to fit your medium flat panel display providing that your display does not exceed the specified weight rating JWP V BEFORE YOU BEGIN e A CAUTION To prevent damage to your display and or the JWP which could affect or void factory warranty thoroughly study all instructions and illustrations before you begin to install the mount Pay particular attention to ALL Warnings and Cautions in this document e The maximum weight allowable for use with the JWP wall mount is 75 lbs 34 kg e The JWP wall mount is designed to be installed using wall studs or supporting framework The structure to which the JWP wall mount is anchored must be capable of supporting five times the total weight of the mount and all attached equipment e f you have any questions about this installation contact Chief Manufacturing at 1 800 582 6480 CHIEF MANUFACTURING INC 8832 000134 Rev B Cc C H F 1
5. f Reinstall display 3 Repeat Steps 1 and 2 until desired tension is Figure 15 Adjust Pitch Tension obtained 14
6. 800 582 6480 952 894 6280 FAX 952 894 6918 2006 Chief Manufacturing 8401 EAGLE CREEK PARKWAY STE 700 www chiefmfg com Ideas Supporting Ideas SAVAGE MINNESOTA 55378 USA 12 06 Installation Instructions JWP V Ad meortant WARNINGS and CAUTIONS WARNING CAUTION e WARNING e WARNING e WARNING e WARNING e WARNING e WARNING e CAUTION A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions Improper installation can result in serious personal injury Make sure that the structural members can support a redundant weight factor five times the total weight of the equipment If not reinforce the structure before installing the mount Be aware of the potential for personal injury or damage to the equipment if it is not adequately mounted The installer is responsible for verifying that the display to which the JWP mount is anchored will safely support the combined load of all attached components or other equipment The weight of the display placed on the JWP must not exceed 75 Ibs 34 kg the maximum support weight of the JWP Watch for pinch points Do not put your fingers between movable parts Make sure the mount and brackets are correctly oriented Check the unit for shipping damage before you begin the installation DIMENSIONAL DRAWING
7. CT UNIT BEFORE INSTALLING A WARNING Watch for pinch points Do not put your fingers between movable parts 1 Carefully inspect mount for shipping damage If any damage is apparent call your carrier claims agent and do not continue with installation until carrier has reviewed damage NOTE Read all instructions before starting installation 2 Lay out components to ensure you have all required parts before proceeding see PARTS on page 6 If you are missing any listed parts contact Customer Service at 1 800 582 6480 SPECIFICATIONS Table 1 JWP Specifications Depth from Wall 3 35 85 07mm Not Applicable Maximum Extension 6 0 x 8 32 x 3 35 152 x 211 43 x 85 07mm Dimensions WxHxD Weight Capacity 75 Ibs 34kg Installation Instructions INTRODUCTION There are 3 main steps in the JWP V installation process These steps are e Selecting an appropriate mounting configuration e Connect display cables e Making required adjustments Before starting the installation process determine the correct mounting hole configuration for your display by reviewing the information located within Table 2 at right NOTE If the displays mounting hole configuration does not match those identified at right a custom MSB interface is required Refer to a Chief Mfg cross reference or visit to www chiefmfg com to identify the appropriate MSB for your display JWP V 200mm x 200mm J 200mm x 100mm
8. ay This procedure provides a general guideline to follow when installing the interface bracket after selecting the mounting hole pattern procedure that matches your display For example To install the interface bracket using the 200mm x 100mm mounting hole pattern use the procedure on page 10 A WARNING You must use proper attaching hardware to install the interface bracket Failure to use proper attaching hardware may result in equipment damage or serious personal injury 1 Lay the interface bracket 20 over the mounting holes on the back of the display making sure to center the interface bracket as much as possible NOTE A typical example of where to place the spacers between the display and interface bracket is shown in Figure 4 2 In general to install the interface bracket do the following a Select the appropriate mounting hole pattern as described in the following sections to attach the interface bracket 20 to back of display b Select the appropriate screws from Bag A or B and spacers from Bag C to mount the interface bracket to the back of the display c Tighten each screw To prevent equipment damage do not over tighten the screws A CAUTION The screw and spacer length must not exceed the depth of the mounting hole Using improper hardware may result in equipment damage or serious personal injury JWP V DISPLAY SCREW MOUNTING PAG AEE HOLE O ye g O SPACER BAG C Figure 4 Attac
9. ct four Phillips head M6 screws from Bag B c Select spacers 120 or 130 from Bag C Attach the interface bracket 20 using the hole pattern on the back of your display as shown in Figure 9 and Figure 10 Tighten each screw To prevent equipment damage do not over tighten the screws JWP V ATTACH BRACKET TO BACK OF DISPLAY USING M4 SCREWS BAG A AND SQUARE HOLES OR M6 SCREWS BAG B AND ROUND HOLES Figure 9 Display with 200mm x 200mm Hole Pattern For round hole Wis 4 use M6 screws For square hole use M4 screws Figure 10 Select Round Hole or Square Hole Installation Instructions Attach Display to Mount Centris Bracket After attaching the interface bracket onto the display the next step is to attach the display to the mount Centris bracket To attach the display to the Centris bracket do the following 1 Select four Phillips head M4 x 8mm screws 80 from Bag A Start two M4 x 8mm screws 80 Bag A into top mounting holes on display see Figure 11 Align mounting holes on Centris bracket with screws installed on display Hang display on Centris bracket Install two remaining M4 x 8mm screws 80 from Bag A into the bottom mounting holes on the display Tighten four screws Proceed to the Cable Management procedure ATTACH MOUNT TO WALL BRACKET To attach mount to wall bracket 1 Align top of mount 10 with top of wall bracket 30 Push bottom of mount against bot
10. hing Interface Bracket to Display Installation Instructions 200mm x 100mm Pattern For the 200mm x 100mm hole pattern do the following 1 Select six flat head M4 screws 60 from Bag A and six spacers 130 from Bag C 2 Attach the interface bracket 20 using the hole pattern on the back of your display as shown in Figure 5 3 Tighten each screw To prevent equipment damage do not over tighten the screws 300mm x 100mm Pattern For the 300mm x 100mm hole pattern do the following 1 Select four flat head M4 screws 60 from Bag A and four spacers 130 from Bag C 2 Attach the interface bracket 20 using the hole pattern on the back of your display as shown in Figure 6 3 Tighten each screw To prevent equipment damage do not over tighten the screws 10 JWP V ATTACH BRACKET TO BACK OF DISPLAY USING M4 SCREWS BAG A AND THESE HOLES aie ay ee i l a fe O fe fe Figure 5 Display with 200mm x 100mm Hole Pattern ATTACH BRACKET TO BACK OF DISPLAY USING M4 SCREWS BAG A AND THESE HOLES E E Oh Nes 0 0 Vi aN Figure 6 Display with 300mm x 100mm Hole Pattern Installation Instructions 300mm x 200mm Pattern For the 300mm x 200mm hole pattern do the following 1 Select eight Phillips head M6 screws 110 from Bag B and eight spacers 120 from Bag C
11. n mounting holes on Centris Bracket with screws installed on display Hang display on Centris Bracket see Figure 2 Install two remaining M4 x 12mm screws 60 into bottom mounting holes on display Tighten four M4 x 12mm screws 60 screws Proceed to Attach Mount to Wall Bracket section of this manual JWP V Pilot Holes 30 oe ee Pl Zs Figure 1 Secure Wall Bracket 40 929000 60 Centris Bracket Figure 2 Flush Mount Centris Bracket to Display Installation Instructions JWP V Recess Mount Installation To recess mount Centris Bracket 1 Lay display down on a flat surface A CAUTION Make sure surface is clean and free of dirt and debris before laying display down 2 Select four screws M4 x 20mm screws 60 and four Display spacers 100 from parts bag 3 Place four spacers 100 over mounting holes on back of display see Figure 3 4 Align mounting holes on Centris bracket with spacers installed on display 5 Install four M4 x 20mm screws 60 to attach Centris bracket to display see Figure 3 Tighten four M4 x 20mm screws 60 screws Proceed to Attach Mount to Wall Bracket section of Figure 3 Recess Mount Centris Bracket to Display this manual Installation Instructions Interface Bracket Installation The following sections describe how to install the interface bracket 20 for a specific hole pattern on your displ
12. se 4 of the 8 spacers for 100mm x 100mm recess mounted Centris bracket For Set Screw For Tension Adjust Use with 120 Use with 130 Use with 130 Installation Instructions SECURE WALL BRACKET A WARNING Itis the responsibility of the installer to verify that the surface to which the mount is anchored will safely support the combined load of all attached components and equipment Install wall bracket as follows 1 Determine exact mounting location prior to installation considering unit s swing arm and extension radius Using wall bracket 30 as a template mark two pilot holes See Figure 1 Drill two 1 pilot holes a minimum depth of 2 into wood stud NOTE Make sure wall bracket is level before installing lag bolts 4 Using a 9 16 socket wrench install two lag bolts 40 IMPORTANT to wall Do not over tighten the lag bolts Over tightening lag bolts may cause bracket to compress into soft wall surface resulting in difficult mount installation or improper engaging of set screw Ref Attach Mount to Wall Bracket page 13 step 2 If this occurs remove bracket install 3 8 steel washers as required between bracket and wall surface and reinstall bracket INSTALLATION 100mm x 100mm Flush and Recessed Mount Installation Flush Mount Installation To flush mount Centris Bracket 1 Start two M4 x 12mm screws 60 into top mounting holes not shown on display Alig
13. tom of wall bracket until mount fits snugly in place seeFigure 12 Using 5 32 hex wrench 140 secure mount to wall bracket by tightening set screw see Figure 13 Ensure set screw engages b 4 k side of bracket to properly secure mount JWP V Display Centris Bracket 30 Figure 12 Attach Mount to Wall Bracket 10 Set Screw Figure 13 Tighten Set Screw 13 Installation Instructions JWP V CABLE MANAGEMENT WARNING Make sure your cables do not run through a pinch points Do not put your fingers between movable parts Lateral Tension Adjustment Bolt For cable management not shown connect and secure power audio video cables making sure to leave sufficient slack to allow for movement of the display ADJUSTMENTS Lateral Tension Adjustment To adjust Lateral Tension 1 Move arms laterally to check for desired tension 2 Using a 3 16 hex wrench slightly tighten or loosen lateral tension adjustment bolts seeFigure 14 3 Repeat Steps 1 and 2 until desired tension is obtained Pitch Tension Adjustment To adjust Pitch Tension 1 Tilt display to check for desired tension 2 If pitch tension in Centris Bracket requires adjustment perform the following steps d Remove Display from Centris Bracket e Using a 3 16 hex wrench slightly tighten or loosen pitch adjustment bolt to adjust Centris Bracket as needed see Figure 15

Download Pdf Manuals

image

Related Search

Related Contents

Tecumseh AVA2515ZXTXF Performance Data Sheet  取 扱 説 明 書  NI WSN-3212 User Guide and Specifications  Whirlpool TUD8700SQ User's Manual  reflex 'variomat' Druckhaltestation Montage-, Betriebs  Panasonic Lumix DMC-FZ150 User`s Manual  Comrac Archer Collection Wall Mount  Région - Journal de la Région Alsace  ESPECIFICACIÓN DE PRODUCTO DIABA HP Cacao 1  取扱説明書ダウンロード(PDF)  

Copyright © All rights reserved.