Home
Chief Manufacturing PAC501 User's Manual
Contents
1. Figure 3 2 Connect electrical wiring 3 Route audio visual cables into housing 4 PAC 501 in opening and insert into opening Align front of box with front face of wall See Figure 4 Figure 4 WARNING ELECTRICAL SHOCK HAZARD CUTTING OR DRILLING INTO ELECTRICAL WIRES OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surfaces is free of electrical wires and cables before cutting drilling or installing fasteners 5 Drill four 3 16 diameter pilot holes in studs at side mounting holes See Figure 5 Figure 5 6 Attach the PAC 501 to side studs using four M7 x 50mm Allen head connector screws D and mounting spacers G using an M4 Allen head drill bit E See Figure 5 NOTE The PAC 501 has 1 2 total clearance between the two studs The spacers allow side to side adjustment 501 Installation Instructions CHIEF Our Mounts Your Vision Chief Manufacturing a division of Milestone AV Technologies 8807 000073 Rev 2008 Milestone AV Technologies www chiefmfg com 10 08 USA International A 8401 Eagle Creek Parkway Savage MN 55378 P 800 582 6480 952 894 6280 F 877 894 6918 952 894 6918 Europe A Fellenoord 130 5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 A Room 24F Block D Lily YinDu International Building
2. LuoGang BuJi Town Shenzhen CHINA AI fp zs 27 AN AS P 486 755 8996 9226 F 486 755 8996 9217 3 7 56 b 9
3. SIMILAR STYLE ELECTRICAL BOX 7 2x 585 2X 1 19 amp 14 Paes hop 2 2200 1804 8 17 5 2X 12 00 457 2 2X R 69 0 18 00 97 9 711 2 kc 2X 28 00 3 83 47 6 101 6 4X 1 88 2X 4 00 304 8 508 2X 12 00 20 00 458 2 18 04 GROUNDING SCREW CONNECTIONS 50 8 p 2X 2 00 b o o o o o m 263 4 MEASUREMENTS IN MILLIMETERS 30 00 INCHES 501 Installation Instructions LEGEND Tighten Fastener Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Pencil Mark Marcar con l piz Stiftmarkierung Marcar com l pis Segno a matita Potloodmerkteken Marquage au crayon Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tou
4. INSTALLATION INSTRUCTIONS IN WALL ENCLOSURE CHIEF 501 Our Mounts Your Vision 501 Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Chief is a trademark of Milestone AV Technologies All rights reserved A IMPORTANT WARNINGS AND CAUTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions NOTES WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty Itis th
5. TH OR SERIOUS PERSONAL INJURY This accessory should be installed by qualified personnel Site Preparation Locate and Prepare Mounting Site 1 Identify a suitable wall location for the in wall enclosure IMPORTANT The 501 is designed for in wall installation spanning a minimum of three wood studs 16 on center Installation of PAC 501 in 2x4 wall results in nearly direct contact with vertical studs and back wall Inadequate space will remain for electrical wires cables plumbing ductwork or insulation Locate installation accordingly WARNING ELECTRICAL SHOCK HAZARD CUTTING OR DRILLING INTO ELECTRICAL WIRES OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surfaces is free of electrical wires and cables before cutting drilling or installing fasteners WARNING EXPLOSION AND FIRE HAZARD CUTTING OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surfaces is free of gas water waste or any other plumbing before cutting drilling or installing fasteners Using a stud sensor locate and mark studs Center and level housing between marked studs 4 Using housing as a template draw pencil line completely around housing See Figure 1 5 Cut drywall on outside edge of line and remove Wood Studs Figure 1 Frame Housing The exposed portion of the center wood stud
6. e installer s responsibility to make sure all components are properly assembled and installed using the instructions provided CAUTION This equipment must be installed and assembled by qualified service personnel in accordance with local building codes WARNING Failure to provide adequate structural strength for this accessory can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this accessory is attached can support the combined weight of the box and all equipment not to exceed 200 Ibs 90 72 kg e SUITABLE FOR USE IN OTHER ENVIRONMENTAL AIR SPACE IN ACCORDANCE WITH SECTION 300 22 C OF THE NATIONAL ELECTRICAL CODE maximum specified ambient temperature of the cabinet system is 40 120 F 4 499 e Minimum spacings between the accessories and components and the housing for Information Technology Communication Equipment shall be maintained for safe operation of the equipment when installed in accordance with the National Electric Code ANSI NFPA 70 1999 Refer to communication equipment manufacturer s specifications for minimum spacings This Cabinet System is for use with ITE or Audio Video equipment only Installation Instructions PAC501 DIMENSIONS 657 2 2X 25 88 ELECTRICAL CUTOUT 581 1 DESIGNED TO FIT A SINGLE GANG 2X 22 88 RACO 590 STEEL CITY CY OR 148 6 30 2
7. must be removed and the resulting cavity completely framed with wood The following steps are suggested The actual procedure is dependent upon the specific installation WARNING STRUCTURAL FAILURE HAZARD FAILURE TO TAKE ADEQUATE PRECAUTIONS CAN LEAD TO DEATH OR SERIOUS INJURY Ensure removal of center stud will not cause unacceptable loss of structural strength Consult a qualified building contractor and applicable building codes Remove exposed portion of center wood stud flush with upper and lower drywall edges r Support VA Blocks Za A Horizontal Framing v f 5 MORS Ej cal for eac 4 Figure 2 Installation Instructions PAC501 2 four 8 long support blocks out of 2x4 wood 3 Using three 10 x 2 1 2 countersunk wood screws not provided attach each support block to the studs See Figure 2 NOTE Ensure screws are far enough from block end to prevent interference with framing screws installed in Step 5 4 If necessary cut rectangular hole in horizontal framing to accomodate the PAC 501 electrical box 5 Attach horizontal framing to each support block with two 10 x 2 1 2 countersunk wood screws not provided See Figure 2 In Wall Enclosure Installation 1 Install junction box B into the PAC 501 A using four 08 x 1 2 Phillips pan head tap screws F See Figure 3
8. rnevis pointe cruciforme Adjust Ajustar Einstellen Ajustar Regolare Afstellen Ajuster Open Ended Wrench Llave de boca Gabelschl ssel Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche Remove Quitar Entfernen Remover Rimuovere Verwijderen Retirez By Hand A mano Von Hand Com a m o A mano Met de hand la main Optional Opcional Optional Opcional Opzionale Optie En option d 9 Hex Head Wrench Llave de cabeza hexagonal 2 DI 9 9 Sechskantschl ssel Chave de cabeca sextavada Chiave esagonale Zeskantsleutel Cl t te hexagonale Security Wrench Llave de seguridad Sicherheitsschl ssel Chave Chiave di sicurezza Veiligheidssleutel Cl de s curit Installation Instructions PAC501 TOOLS REQUIRED FOR INSTALLATION g 3 16 C 8 M7 x 40mm D M7 x 4 50mm Q Grounding screw and washer installed at factory QD Earthing symbol IEC 6 affixed adjacent to grounding terminal 0418 No 5019 F 10 08 x 1 2 E 1 M7 501 Installation Instructions INSTALLATION WARNING IMPROPER INSTALLATION CAN RESULT IN DEA