Home
Chaney Instrument L5C0964TX User's Manual
Contents
1. Minutes gt DST on off Turning DST off disables the Daylight Saving Time setting ADDITIONAL FEATURES Using ALARM 1 ALARM 2 4 This unit has two alarms that can be set independently of one another Select ALARM 1 or ALARM 2 by pressing the ALARM button Hold the ALARM button for 3 seconds Press or to enter the desired alarm time and press ALARM to confirm the setting Please be sure to note the PM indicator to ensure you have set the alarm for the proper time To view alarm time 1 and 2 simply press the ALARM button to read ALARM 1 and ALARM 2 The alarm time will be displayed for 5 seconds and then revert to the normal clock display To turn AL 1 AL 2 on and off press button When alarm one is set a bell with a number one will show next to the right of the calendar When the second alarm is set a bell with a number two will appear to the right of the calendar If both alarms are set both bells will appear The unit will sound a Crescendo Alarm which will last for 2 minutes before turning itself off Pressing the Snooze button will repeat the alarm after 5 minutes Use the ALARM button to turn the alarm off completely Low Battery Indicator mn A low battery indicator is shown on the main unit display panel for the home unit itself and all of the remote channels Replace the batteries and follow the setup procedure as mentioned in this instruction manual 4 SPECIFICATIONS Range of temperature measuremen
2. The time signal reception is also greatly affected by electrical or electronic interference If the home receiver location you selected does not work change to a location in another part of the room or building Radio Controlled R C Time Reception Set Up The clock attempts to synchronize with the Atomic time signal AUTOMATICALLY right after the first remote sensor is registered The unit starts synchronizing the clock after registering the remote sensor thermometer reading The clock will not respond to any manual settings while attempting to receive the Radio Control Time signal This reception cycle lasts from 2 to 5 minutes The tower icon in the left hand corner of the screen appears fixed when reception is successful To turn the reception off and to enable manual settings press the gt button Entering the Time Zone After establishing your time signal press SET ZONE once to select PST MST CST or EST time zones A small P M C Eicon will appear to the left of the time display for the respective time zone P Pacific Standard Time M Mountain Standard Time C Central Standard Time E Eastern Standard Time How to Manually Synchronize Your Atomic Clock Hold the button for 3 seconds to trigger a manual synchronization The tower will flash regularly during synchronization Signal strength level is indicated in this way 1 Very Weak or no signal 2 Weak 3 Good 4 Icon appears fi
3. WIRELESS WEATHER STATION INSTRUCTION MANUAL Thank you for purchasing this Chaney Instrument electronic weather station Designed and engineered with the state of art technology and components this instrument provides accurate and reliable measurements of air pressure indoor and outdoor temperature and humidity together with an Atomix Radio Controlled perpetual calendar clock Follow the step by step instructions in this manual carefully to set the following functions setting up the wireless thermometer synchronizing the atomic clock and setting the weather forecaster Other functions explained in this manual include utilizing the dual alarm feature as well as manually setting time date and weather settings A Goel AGURITE Bracket Stand FUNCTION BUTTONS A Snooze Light Button E Clear Button B Alarm Button F Q C CH Channel Button G R D Min Max Button H Set Button STEP ONE SETTING UP THE WIRELESS THERMOMETER Home Receiver Set Up For the initial installation always insert batteries to the home unit first and then the remote sensor Remove the battery cover on the back and install 2 AA alkaline or lithium batteries not included according to the polarity indicated Replace the battery cover The home unit will start to search for a sensor
4. e sensor after the weather conditions are entered Resetting Weather Conditions If the weather forecast deviates from the existing conditions after the initial setup you can change the weather offset in this manner 1 Hold the CLEAR button for 3 seconds to enter the pressure offset mode The weather icon will flash 2 Select the existing weather condition by pressing MIN MAX 3 Press CLEAR to confirm your selection and exit the setting mode Selecting Celsius Fahrenheit display on home unit Hold MIN MAX button 3 seconds to select C or F WEATHER FORECAST with Storm Alert The built in precision Barometric pressure sensor will read the atmospheric pressure and calculate the weather conditions for the next 12 hours The Icons will show oS Stormy Flash Sunny Partial Sunny Cloudy Pressure Temperature Humidity Trend Indicators Small arrow icons displayed in boxes will indicate Rising Steady Falling Refresh rate is once every hour Moon Phase Moon Phase is shown by the scrolling of the moon icon from left to right The icon will stop at the existing moon phase for 5 seconds and then resume scrolling O0O00Od06 Manually Adjusting Clock amp Calendar Setting Hold the SET button for 3 seconds to enter the clock setting mode Using or to adjust and SET to confirm the following values can be set in sequence 12 24 hr gt Year gt Month gt Date gt Hour gt
5. lacing the batteries in the remote sensor remember to clear the corresponding channel on the home receiver unit in this way Select the respective channel by pressing the CH button hold the CH button 3 seconds to clear the channel Placement of Remote Sensor Place the remote sensor out of direct sunlight and direct exposure to rain or snow At extremely low temperatures below 15F battery voltage output decreases The low temperatures may cause your outdoor temperature reading to go blank Using lithium batteries can increase the effective temperature range as they function at lower temperatures than alkaline batteries For prolonged periods of extreme cold we recommend the remote sensor be brought indoors Metal structures walls and electrical interference can shorten the transmission range of the remote sensor Please try several locations to determine the best reception of the signal by the home unit STEP TWO SETTING THE ATOMIC CLOCK About The Atomic Clock The National Institute of Standard and Technology NIST in Fort Collins Colorado broadcasts the time signal WWVB at 60kHz AM radio signal with an accuracy of one second per every 3 000 years The signal covers a distance up to 2 000 miles from the source Selecting the Ideal Location Like atypical AM radio the Atomic Clock will not receive the WWVB signal in places surrounded by heavy concrete or metal panels For best reception please install the home receiver near a window
6. t Indoor unit 5C to 50 C 32F to 122F Remote sensor 20C to 60C 14F to 158F Transmission 100 feet 30M in an open area RF434 MHz Resolution 0 1 degree Clock WWVB Radio Controlled Atomic Clock Battery Req 2 AA for the main unit 2 AAA for each remote sensor Battery life 12 months alkaline batteries recommended not included Button Functions Press Button Once Press and Hold for 3 seconds Side Buttons CHANNEL Select Channel 1 2 or 3 Delete Current Channel Reading For Viewing Advance Setting Forward by 1 Unit Fast Forward Setting Turn Alarm 1 and or Alarm 2 on amp off Change Setting Backward by 1 Unit Fast Backward Setting Start or Stop Radio Controlled Time Signal Search MAX MIN View max amp min memory for Hold to select C F temperature amp humidity CLEAR Clear the Max Min memory Weather Offset AL Read Time Settings for Alarms 1 amp 2 Set time for Alarms 1 amp 2 Alarm Stop Back Button SET Select Time Zone Enter clock amp calendar setting PST MST CST EST Top Button SNOOZE LIGHT Activate snooze alarm and green backlight
7. transmitting outdoor temperature amp humidity information during the first 5 minutes after entering the existing weather condition To enter the existing weather conditions select the correct weather condition by pressing MIN MAX and press CLEAR to enter The home unit will try to seek for a remote sensor after the weather conditions are entered The outdoor temperature and humidity section will flash during channel registration If you press the CH key it will disable the registration mode and go to radio controlled clock reception mode Remote Sensor Set Up Remove the bracket stand and remove the 4 screws with a small Philips head screwdriver Insert 2 AAA alkaline or lithium batteries not included according to the polarity indicated Set Channel 1 for the first remote sensor You must set to Ch 1 if only one sensor is in use One sensor is included with the base unit Additional sensors may be purchased separately Set channel 2 if using a second sensor or channel 3 if using a third sensor e To verify transmission of a signal press the TX button inside the battery compartment of the remote sensor The red LED on the front of the remote sensor will flash when it successfully transmits a signal Temperature and humidity of the remote sensor will be updated and displayed on the remote sensor e Select Celsius or Fahrenheit by pressing the C F button inside the battery compartment Replace the cover and tighten the 4 screws e When rep
8. xed Reception successful 5 Icon does not show No signal received amp decoded If signal level is weak and time reception is not successful move the unit away any source of possible interference and try again in another location The R C clock will attempt a daily synchronization at 1 00 AM everyday If not successful the R C clock will search for the time signal every hour Each R C reception cycle lasts from 2 minutes to 5 minutes To avoid interference the unit will disable the other button functions during Radio Controlled Time reception This is not a defect Simply press P button to turn Radio Controlled Time reception temporarily off Daylight Saving Time DST Feature The feature is enabled when the batteries are installed The DST icon appears in the upper right hand corner For areas not using DST in summer select DST off mode as described under Manually Adjusting Clock amp Calendar Setting STEP THREE SETTING UP YOUR WEATHER FORECASTER Enter Existing Weather Conditions To ensure a more accurate weather forecast based on the altitude of your location enter the existing weather conditions The unit will relate the existing weather conditions with the current air pressure level The home unit will ask you to enter the existing weather conditions right after installing the batteries Please select the correct weather condition by pressing MIN MAX and press CLEAR to enter The home unit will try to seek for a remot
Download Pdf Manuals
Related Search
Related Contents
DVR User Manual User's Manual for LINEAR , a FORTRAN Program to Derive Acer Iconia W3-810-27602G03nsw 32GB Silver INSTRUCTION MANUAL 取付説明書 M-8タイプ 取扱説明書 Improved Throughput in Network Analyzer Applications Manual PDF bdiGDB User Manual 9面 - 成田市 VGN-FW100 Series - Manuals, Specs & Warranty Copyright © All rights reserved.
Failed to retrieve file