1. INSTALLATION amp MAINTENANCE CEM INSTRUCTIONS AEROFAN SUPERIOR BATHROOM FANS READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE PACKAGE CONTENTS e AeroFan superior bathroom fan e Mounting brackets 3 e Lamps 26W PL amp 4W night light selected models only BEFORE INSTALLATION 19 The fan must not be installed in a ceiling with an R rating greater than 40 WARNING 20 To reduce the risk of injury install the fan at least 2 1m TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR 7 feet above the floor INJURY TO PERSONS OBSERVE THE FOLLOWING 21 The following models are suitable for installation over a shower or tub when installed in a GFCI protected branch 1 Use this unit in the manner intended by the manufacturer circuit TBF90 TBF120 TBFR9OL and TBFR120L If you have any questions contact the manufacturer 22 WARNING To reduce the risk of fire or electrical shock do 2 Before servicing or cleaning unit switch power off at service not use this fan with any solid state speed control device panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service CAUTION disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 1 For general ventilating use only Do not use to exhaust 3 Installation work including the electrical wiring must hazardous or
2. a complete description of our Limited Warranty conditions visit www continentalfan com Canada www aeroflo com Aeroflo Inc 12 205 Matheson Blvd East Mississauga ON L4Z 3E3 Tel 905 890 6192 Toll 800 779 4021 Fax 905 890 6193 USA Continental Fan Manufacturing Inc 203 Eggert Rd Buffalo NY 14215 Tel 716 842 0670 Toll 800 779 4021 Fax 716 842 0611 www continentalfan com AEROFAN I amp M 1005 AEROFAN WIRING DIAGRAMS FAN ONLY MODELS TBF90 TBF120 SWITCH BY OTHERS EXHAUST FAN OFT MODEL TBF90 amp TBF120 OFF E HIGH CAPACITOR HOT z 115V POWER LOW 9 SUPPLY GROUND NEUTRAL C sees NOTE MULTIPLE SINGLE POLE SWITCHES MUST NOT BE USED FAN MOTOR FAILURE WILL OCCUR REQUIRES THE USE OF ONE THREE POSITION SWITCH FOR OFF HIGH AND LOW SPEED FAN LIGHT COMBINATION MODELS TBFR9OL TBFS90L TBFR120L TBFS120L i TO NIGHT LIGHT BY OTHERS TO BATHROOM LIGHT BY OTHERS SPEED CONTROL SWITCH 3 CIRCUIT CONTROL SWITCH LEVITON 3 WAY SWITCH LEVITON COMBINATION SWITCH OR EQUAL OR EQUAL EXHAUST FAN MODEL TBF90 amp TBF 120 NIGHT LIGHT E A SZT J GREY COMMON MOTOR cS es 117 V GE 7 WHITE ower FAN 7 SUPPLY BLACK GROUND AEROFAN I amp M 1005
3. explosive materials and vapors be done in accordance with all applicable codes and 2 This product is designed for installation in flat ceilings standards by a qualified person only Do not install it in a sloping ceiling or in a wall 4 When cutting into ceilings take care not to damage 3 To avoid motor bearing damage and noisy unbalanced concealed electrical wiring or any other hidden utilities impellers keep construction material dust from entering 5 Ducted fans must always be vented to the outdoors the fan 6 NEVER place a switch where 4 Please read specification label on the product for further it can be reached from a r a information and requirements tub or shower To prevent Se electrical hazards the fan oa FAN INSTALLATION must be installed so as to prevent water from entering The fan should only be installed in a ceiling see figure 2 for a the fan The fan must not be typical installation The fan will accommodate a joist spacing installed in a place that is of 16 with a minimum clearance height of 9 prone to water leakage 7 Not for use in cooking PONET Housing Fan Outlet areas Figure 1 Figure 1 S 8 These fans must be mounted ss to structural members that are strong enough to support the fan s weight 9 The fan must be properly grounded 10 Do not allow foreign objects to enter the fan this could B a result in electric shock or fan damage l es 11 Do not block the air intake or exhaust Ceiling Electric
4. 20 60 25 26 4 750 1050 60 90 TBFS120L 120 60 40 26 4 775 1050 90 120 TBFR90L 120 60 25 26 4 750 1050 60 90 TBFR120L 120 60 40 26 4 775 1050 90 120 CONDENSED WARRANTY All warranty claims must be processed through point of purchase All warranty repair work must be authorized by Vendor AeroFan Superior Bathroom Fans are warranted against defects in material and workmanship for a period of three years from date of purchase Warranty does not include consumable components such as lamps All other products are warranted for a period of one year from date of purchase WARRANTY DOES NOT APPLY TO Shipping damage either concealed or visible Claims must be filed with the carrier Damage caused by improper installation wiring or incorrect electrical voltage Materials that have been modified altered or disassembled Materials that have had the identification labels removed or altered Materials that have been subjected to abuse misuse abnormal usage or accident e Damage caused by corrosion erosion abrasion or severe temperature e Materials that have not been properly maintained No other warranties expressed implied or written shall apply to this product Vendor will not be responsible for any consequential or incidental damages loss of property revenues or profit cost of removal installation or reinstallation personal damage or loss of life or for any breach of warranty regardless of how caused For
5. al Mounting Electrical 12 The fan should not be turned on and off rapidly Box boc oa Een 13 If the fan is not operating properly shut the power off Figure 2 immediately and have a certified electrician inspect it and have it serviced as required 14 Do not clean the fan with corrosive chemicals nor water in 1 Remove the grille by excess of 60C 140F gently squeezing the 15 Power supply wiring is to be No 14AWG wire or larger wire springs and 1 s suitable for at least 90C 190F extracting them from A my 16 Not for use outdoors the slots in the housing es ea es 17 For the lighted units use only PL type 26W lamps and 2 Remove the electrical Cet a maximum of 4W type E12 T20 lamp for the night light box cover and install A SL models TBFR90L TBFS90L TBFR120L TBFS120L the 3 brackets on the i 18 The fan is type IC Inherently Protected fan housing Figure 3 Figure 3 To install the housing in the ceiling position it between the joists and extend the brackets to the b adjacent joists Mark the screw locations at the top of the keyhole on each bracket on the joists Note make sure to allow the appropriate depth for the particular ceiling type The bottom edge of the housing should be flush with the ceiling Figure 4 Remove the housing and drive the screws part way into the joists at the marked locations Mount the housing using the screws in the joists and then secure them tightly Make all t
6. he electrical connections in the electrical box per the wiring diagram and attach the electrical box cover Attach the discharge duct tightly onto the fan outlet Ceiling Figure 4 Note In order for the fan to operate efficiently keep the discharge duct as straight as possible 6 To complete the installation install the lamps if applicable and mount the grille RECOMMENDED MAINTENANCE 1 Turn the power off and lock it out prior to servicing or cleaning 2 To clean the grille first remove it from the fan then use a soft brush and clean water to remove the dirt If the dirt is not easily removed wash with a neutral detergent 3 In order to remove the impeller and housing for maintenance first remove the light night light and reflector if applicable Then unplug the electrical connection and remove the 4 screws that secure the fan assembly to the housing To clean the impeller and housing remove the motor and then wash with water or a neutral detergent as required Note Keep all electrical components away from water Do not use corrosive chemicals or water in excess of 60C 140F to clean plastic parts WIRING PROCEDURE Refer to the wiring diagram FAN SPECIFICATIONS MODEL VOLTAGE FREQUENCY POWER CONSUMPTION W SPEED AIRFLOW V HZ MOTOR PLLAMP NIGHT LIGHT RPM CFM TBF90 120 60 25 p 750 1050 60 90 TBF120 120 60 40 775 1050 90 120 TBFS90L 1
Download Pdf Manuals
Related Search
Related Contents
Contenido Peinture pour plafond bloque 採用事例集 No.2 MSI Classic CR640-221ZA notebook FUNAI CSV205DT Owner's Manual TP-Link TD-8816 V7 Quick Installation Guide All in One - Marine Electric Cabinet international standard norme internationale NightView User`s Guide - Version 6.1 拡張モジュール 取扱説明書 - 固定IP接続回線・全国対応 ipq Copyright © All rights reserved.