Home
CFM CX1000 User's Manual
Contents
1. CONTINENTAL 1000 Complete Air Purification System Portable Unit User s Guide Read and save these Instructions Continental Fan Manufacturing Inc Buffalo NY U S A TABLE OF CONTENTS IMPORTANT SAFETY 5 3 SPECIFICATIONS 228 2 ee ah 3 FEATURES ut 4 UNPACKING THE 1000 5 INSTALLING THE 1000 5 USINGSTHE EXT000 32 ar erregen 5 SELECT la ae cues ahd ae are ee 6 SELECT OPERATING 7 MONITORING 7 SERVICE PANEL INDICATOR 5 8 UV LAMP INDICATOR 5 8 FILTER INDICATOR 5 8 PERFORMING 9 REPLACING THE 9 REPLACING THE 5 10 LIMITED LIFETIME 11 IMPORTANT SAFETY INSTRUCTIONS Always unplug the CX1000 when it is not in operation while the filters or UV light are being changed and when cleaning the unit After servicing the unit both the front and top grill assemblies must be reinstalled in exactly the same manner as prior to removal If either grill is no
2. Place the CX1000 in a location that will not restrict air flow through either the air inlet or the air outlet Plug in the electric cord at the nearest electrical wall outlet USING THE CX1000 1 Press POWER button to turn on the CX1000 Lights on the control panel figure 1 will light and the UV lamp will be on figure 1 Motion Sensor AIR PURIFIER ojuax lo jo Min VOLUME Chemical Sensor 2 Look into the air outlet at the top of the CX1000 to confirm that the UV lamp is operating There is a faint blue glow when the lamp is on If the lamp appears to be off refer to UV LAMP INDICATOR LIGHTS page 8 When the lamp is on the product is ready for operation SELECT ROOM SIZE 1 Determine the area of the room the CX1000 is to purify 2 From the table below identify the respiratory condition the unit is to serve Heavy Duty People with Severe Respiratory Problems Super Mode SQ FT SQ METERS Extra Large 650 65 Auto Mode SQ FT SQ METERS Super Mode Extra Large Auto Mode Extra Large 550 55 Large 450 45 Medium 400 40 Small 350 35 X Small 30 Extra Large Large Medium Small X Small 3 Use the Heavy Duty chart if you suffer severe allergic reactions when exposed to particulate matter pollen dust dust mites animal dander etc or airborne chemicals pesticides herbicides clean ing solutions etc 4 Use the Light Duty chart if you occasion ally suffer from mild
3. allergies 5 Select the desired ROOM SIZE by pressing the SELECT button figure 2 Light Duty Average home SQ FT SQ METERS 2000 200 SQ FT SQ METERS 1700 1450 1200 1050 900 figure 2 170 145 120 100 90 oS eee X LARGE LARGE MEDIUM SMALL X SMALL ROOM SIZE SELECT OPERATING MODE Select the desired operating MODE by pressing the SELECT button figure 3 AUTO MODE This is the mode most com monly used In AUTO MODE the Chemical Sensor figure 1 controls the blower speed If the Chemical Sensor detects an unhealthful amount of chemicals present in the air indi cated by the red light on the quality scale the electronic controls will automatically increase blower speed figure 3 SUPER MODE SUPER MODE may be select ed during periods of high air pollution such as when winds increase airborne dust and pollen or during heavy room loading parties or smoking Blower speed will increase 25 percent above AUTO MODE ECONOMY MODE ECONOMY MODE saves energy when the room is unoccupied When the Motion Sensor figure 1 detects no motion for 30 seconds blower speed is reduced to save electricity costs The blower returns to normal speed when motion is again detected SLEEP MODE SLEEP MODE reduces the sound level by slowing blower speed by 30 percent while still purifying room air at 70 percent of normal operation MONITORING OPERATION The Chemical Sen
4. at no charge for labor or materials This warranty does not cover the expendable UV lamp which must be replaced on an annual basis 1 year or the expendable filter cartridge media which must be replaced every two years or sooner depending on environmental conditions All warranty repair work must be performed either at the factory or by a factory certi fied service center Shipping cost to the factory or service center is the responsibility of the owner of the CX1000 To return product for warranty repair the customer must first contact the factory for a Return Materials Authorization RMA number and a ship to address as it may differ from the manufacturing location For material repaired under warranty ship ping costs to the customer will be prepaid for the first two years only This warranty is provided to the original purchaser of the CX1000 and may not be transferred sold or bartered This product is not warranted against freight damage failure resulting from misuse connection to incor rect voltage or acts of God such as fires earthquakes or floods L4 CX1000 UG 0505 Continental Fan Manufacturing Inc 203 Eggert Road Buffalo New York 14215 Tel 800 779 4021 Fax 716 842 0611 email cfm continentalfan com web www continentalfan com
5. ervice Panel with a pin or similar object The LAMP light will return to green and the time will be reset to zero REPLACING THE FILTERS When the Yellow SERVICE SOON FILTER figure 8 indicator lights the filters should be replaced within 30 days 1 Restore the CX1000 to normal operation as follows 1 Unplug the CX1000 power cord from the electrical outlet Rest the CX1000 on its back figure 8 to access the bottom of the unit Press in locking clips at each end of the front grill Lift bottom of grill and slide out the grill from the top of the unit figure 9 Pull out the two filters individually and discard them Install new HEPA filter in lower slot with its white layer facing upwards Install new pre filter in the remaining slot with its green side facing upwards Replace grill Slide upper end into grill slot and snap the bottom into place so that it locks Reset the filter replacement timer by lightly pressing the FILTER RESET button on the Service Panel with a pin or similar object The figure 10 FILTER light will become green and time will be reset to zero Set the unit in its normal operating position Plug the power cord into the wall outlet LIMITED LIFETIME WARRANTY Each CX1000 Complete Air Purification System comes with a limited life time warranty This warranty provides for repair or replacement of any defective parts or components for two years from the date of purchase
6. sor continually monitors air figure 4 QUALITY and in AUTO MODE controls blower speed and air volume 2 Both air QUALITY and air VOLUME dis played on the INFORMATION panel figure 4 O0000 5 Air QUALITY is indicated by one of five lights indicating a range from GOOD to POOR figure 4 2 QUALITY VOLUME Sae INFORMATION Air VOLUME is indicated by one of seven lights representing a range from MAX to MIN figure 4 Set the CX1000 to move a volume of air appro priate for room conditions Note that measurements are relative to the selected room size Make sure that the ROOM SIZE panel figure 2 is always set for the room in which the unit is to operate SERVICE PANEL INDICATOR LIGHTS The SERVICE panel figure 5 indicates when maintenance is required Lights on the SERVICE panel indicate if either the UV lamp or the air fil ters will soon need to be replaced or if they must be replaced before using the CX1000 again UV LAMP INDICATOR LIGHTS The UV lamp has a useful life of one year figure 5 ae ety 9 000 hours with a one month grace period Green ON light is on The lamp has been in service for less than 12 months e Yellow SERVICE SOON light is on The lamp has been in service for more than 12 months The lamp should be replaced LAMP FILTER Red SERVICE NOW light is The lamp RESET 9 has been in service for more than 13 mon
7. t reinstalled properly the CX1000 will not function This is a built in safety feature Before using the CX1000 extend the power cord and inspect for any signs of damage Do not use the unit if the power cord has been damaged Warning This appliance is designed to be used on a flat and level sur face and may not work properly on an uneven surface To reduce the risk of electric shock and injury do not place in a window Always place the CX1000 at least 12 inches 30 centimeters away from heat sources such as stoves radiators or heaters Do not move the CX1000 while it is in operation Always unplug the unit prior to moving it Do not immerse the CX1000 in water as permanent damage will occur Read and save these instructions SPECIFICATIONS Manufacturer Continental Fan Manufacturing Inc Model 1000 Voltage 1 120V 60 Dimensions 21 5 W x 18 0 H x 8 0 D Maximum Amps 0 95 Maximum Watts 110 Max Air Flow 265 cfm UV Range 254 NM germicidal Weight 23 LBS Application 1000 sq feet auto mode 2000 sq feet super mode Catalyst Titanium Dioxide Pre Filter 5 micron HEPA Filter 0 3 micron hospital grade Service UV LAMP 1 year FILTERS 2 years FEATURES Thank you for purchasing the CX1000 Complete Air Purification System This unit features unique air purification technologies not found in any other air purifier Only CX1000 combines these features A quiet energy efficient back
8. ths The lamp may not be effective SERVICE and must be replaced FILTER INDICATOR LIGHTS The filters have a useful life of two years in a typical residential environ ment e Green ON light is on The filters have been in service for less than 24 months e Yellow SERVICE SOON lisht is on The filters have been in service for more than 24 months The filters should be replaced Red SERVICE NOW light is on The filters have been in service for more than 25 months The filters may not be effective and must be replaced PERFORMING MAINTENANCE Required Maintenance is Replace the UV 1 year Replace the filters 2 years REPLACING THE UV LAMP When the yellow SERVICE SOON lamp indicator lights the UV lamp should be replaced within 30 days 1 2 3 4 5 6 Unplug the power cord from the electrical outlet Using index fingers squeeze the locking tabs figure 6 inward towards the center of the grill on top of the CX1000 Lift the grill and remove figure 6 i ff N m i Rotate UV lamp one quarter turn top to rear figure 7 and remove lamp figure 7a Insert new UV lamp by rotating one quarter turn top to front Replace grill by pressing it into position until it locks The alu minum reflector must be positioned over the lamp nearest the front of the unit figure 7a Reset UV lamp timer by lightly pressing the LAMP RESET button on the S
9. ward curved motorized impeller that moves 265 cfm of air An advanced electronic control system that monitors air quality room occupancy air flow and filter and UV lamp replacement time A six stage filtration system with gas adsorption media that removes toxic gas organic hydrocarbons exhaust fumes formaldehyde clean ing chemicals low level ozone unpleasant odors and paint solvents A hospital grade three stage HEPA filter that removes allergens such as pollen mold fugal spores tobacco smoke insecticide dust dust mites and particles as small as 0 3 microns A photo catalytic oxidation chamber that controls the spread of air borne disease in the home environment UV light kills viruses and bac teria on contact Photo Catalytic Titanium Oxidation activated by the UV light destroys airborne impurities too small to be filtered out Small amounts of residual activated oxygen and negative ions keep the air clean and fresh in exactly the same way sunlight and oxygen clean the air we breathe in an outdoor environment UNPACKING THE CX1000 Before unpacking the unit inspect the shipping container for visible dam age If you feel that you may have received the unit in a damaged condi tion notify the shipper or supplier before opening the container Remove the unit from the box and inspect it for damage Handle it carefully Do not drop it INSTALLING THE CX1000 CAUTION THIS PRODUCT IS DESIGNED FOR INDOOR USE ONLY
Download Pdf Manuals
Related Search
Related Contents
Installation, Wiring, and Specifications 取扱説明書 LEDプラケツ ト Operating instructions 40 Series Panels - BenchMark Wireline Manual do utilizador Guia de Software SimmRate Manual Istruzioni d`uso - Ferrari Service opel.it Hotpoint EH10 User's Manual User Manual iPazzPort cast - iPazzPort Copyright © All rights reserved.
Failed to retrieve file