1. AND DEATH The work setup and storage areas must all be well ventilated CO2 is an invisible Output Gas Pressure Dial odorless gas which can cause 4 Close the Regulator Control Knob serious injury or death if it completely by turning it counterclock accumulates wise Regulator Control Knob REV 09c SKU 99901 For technical questions please call 1 800 444 3353 Page 5 SKU 99901 CO Canister Connector Belt Hook Regulator Knob Female Output Connector Bottom View of Item Insert a standard 20 oz CO bottle not included into the opening at the bottom of the regulator Turn the canister clockwise to screw it into the Connector Tighten firmly to prevent leaks Adjust the Regulator Control Knob so that the air output is enough to prop erly power the tool but the output will not exceed the tool s maximum air pressure at any time Adjust the pressure gradually while checking the air output gauge to set the right pressure range Inspect the air connections for leaks Tighten connections to eliminate leaks Connect Hose to tool not included by pressing coupler onto inlet The CO Regulator has a built in hook that can be used to hang it from a belt Connect the Hose to the CO2 Regu lator by pressing it onto the outlet The pressure supplied to the tool can be adjusted by turning the Regulator Control Knob Turn counterclockwise to reduce pressure Turn clockwise to increase pressure The pres
2. Camarillo CA 93011 800 444 3353 Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead SKU 99901 For technical questions please call 1 800 444 3353 Page 8
3. list are available for this tool Troubleshooting Possible Causes Likely Solutions Decreased output 1 Not enough air pressure and Check for loose connections and make sure or air flow that regulator is set at required pressure Do not exceed maximum air pressure Air leaking from loose hose Make sure hose is properly connected and connection tight Mechanism contaminated Have qualified technician clean mechanism CO pressure is low or Replace CO canister depleted Severe air Cross threaded components Check for incorrect alignment and uneven leakage gaps If cross threaded disassemble and Slight air leakage replace damaged parts before use is normal Incorrectly installed CO2 Reinstall if cross threaded Tighten if especially on older canister loose Make sure o ring is in place at top of tools regulator threaded connection Damaged valve or hose Replace or repair damaged hose Have qualified technician repair valve Follow all safety precautions whenever diagnosing or servicing the tool Disconnect air supply before service SKU 99901 For technical questions please call 1 800 444 3353 Page 7 LIMITED 1 YEAR WARRANTY Harbor Freight Tools Co makes every effort to assure that its products meet high quality and durability standards and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of one year from the date of purchase
4. 99901 Personal safety Stay alert Watch what you are do ing and use common sense when operating the regulator Do not use the regulator while tired or un der the influence of drugs alcohol or medication A moment of inatten tion while operating the regulator in creases the risk of injury to persons Avoid unintentional starting Be sure the tool switch is off before connecting to the CO2 Regulator Do not connect the tool to the CO2 Regulator with the switch on Always wear eye protec tion Wear ANSI ap proved safety goggles Always wear hearing protection when using the regulator Prolonged exposure to high intensity noise is able to cause hearing loss Regulator use and care Use only with tools specifically de signed for use with bottled gasses Read tool manual before connec tion and or use Assemble use and store in a well ventilated area only Carbon dioxide gas is invisible and odorless can ac cumulate in confined spaces Use with carbon dioxide gas only Attach the Hose properly to the Regulator and tool before use A loose Hose may detach or break dur ing operation g For technical questions please call 1 800 444 3353 Do not use the regulator if the Regulator Control Knob does not function properly Any regulator that cannot be controlled is dangerous and must be repaired Disconnect the tool from the CO Regulator before making any ad justments changing accessories or
5. CENTRAL PNEUMATIC Professional PORTABLE COMPRESSED CO REGULATOR Kore 11 99901 OPERATING INSTRUCTIONS Distributed exclusively by Harbor Freight Tools 3491 Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury SAVE THIS MANUAL Copyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual product may differ slightly from the product described herein Tools required for assembly and service may not be included For technical questions or replacement parts please call 1 800 444 3353 SAVE THIS MANUAL Keep this manual for the safety warn ings and precautions assembly operating inspection maintenance and cleaning pro cedures Write the product s serial number in the back of the manual or month and year of purchase if product has no num ber Keep this manual and the receipt in a safe and dry place for future reference Safety Alert Symbol and Signal Words In this manual on the labeling and all other information provid ed with this product This is the safety alert symbol It is used to alert you to potential perso
6. This warranty does not apply to damage due directly or indirectly to misuse abuse negligence or accidents repairs or alterations outside our facilities nor mal wear and tear or to lack of maintenance We shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclu sion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MER CHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the com plaint must accompany the merchandise If our inspection verifies the defect we will ei ther repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement We will return re paired products at our expense but if we determine there is no defect or that the defect resulted from causes not within the scope of our warranty then you must bear the cost of returning the product This warranty gives you specific legal rights and you may also have other rights which vary from state to state 3491 Mission Oaks Blvd PO Box 6009
7. andard conditions National pipe thread tapered National pipe thread straight WARNING marking concerning Risk of Eye Injury Wear ANSI approved eye protection WARNING marking concerning Risk of Hearing Loss Wear hearing protection WARNING marking concerning Risk of Respiratory Injury Wear NIOSH approved dust mask respirator WARNING marking concerning Risk of Explosion SKU 99901 For technical questions please call 1 800 444 3353 Page 4 pBECIEICPATIONC TO PREVENT SPECIFICATIONS AWARNING 19 PREVENI Pressure compressed CO3 with this regulator Do not use oxygen Eie Hose Fittings Female Quick Connectors AWARNING SERIOUS INJURY Do not adjust any control or UNPACKING component in a way not specifically explained within this manual Improper adjustment can result in regulator failure or other serious hazards When unpacking check to make sure that the item is intact and undamaged If any parts are missing or broken please call Harbor Freight Tools at the number shown throughout the manual as soon as possible Female Hose Quick Connector e This product may be shipped with a protective plug covering the air inlet outlet Remove this plug before set up Belt Hook OPERATION i Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product TO PREVENT AWARNING SERIOUS INJURY
8. nal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER indicates 4 DANGER a hazardous situation which if not avoided will result in death or serious injury AWARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury ACAUTION CAUTION used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury SKU 99901 For technical questions please call 1 800 444 3353 NOTICE is used to NOTICE address practices not related to personal injury CAUTION without CAUTION the safety alert symbol is used to address practices not related to personal injury IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TOA RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS WARNING When using regulators basic precautions should always be fol lowed including the following General a To reduce the risks of electric shock fire and injury to persons read all the instructions before us ing the regulator Work area a Keep the work area clean and well lighted Cluttered benches and dark areas increase the risks of electric shock fire and injury to persons b Keep bystanders children and visitors away while operating the regulator Distractions are able to result in the loss of control of the regulator Page 2 SKU
9. storing the tool Such preventive safety measures reduce the risk of starting the tool unintentionally Turn off and detach the CO2 supply safely discharge any residual pressure and release the throttle and or turn the switch to its off position before leav ing the work area Store the regulator and gas canis ter when idle out of reach of chil dren and other untrained persons A regulator is dangerous in the hands of untrained users Do not exceed 150 PSI input pres sure WARNING The brass compo nents of this product contain lead a chemical known to the State of California to cause birth defects or other reproductive harm California Health amp Safety code 25249 5 et seq The warnings and precautions discussed in this manual cannot cover all possible conditions and situations that may occur It must be understood by the operator that common sense and caution are fac tors which cannot be built into this product but must be supplied by the operator Page 3 Service a Regulator service must be per formed only by qualified repair personnel Replacement parts are not available for this product Discard product if it cannot be repaired by technician b Inspect before every use do not use if parts are loose or damaged SAVE THESE INSTRUCTIONS Symbol Definitions Symbol Property or statement Pounds per square inch of pressure Cubic Feet per Minute flow Cubic Feet per Minute flow at SCFM st
10. sure setting is shown on the Output Gas Pressure Dial Adjust the Regulator knob to the pressure recommended by the tool manufacturer Do not exceed the tool s maximum air pressure rat ing Note Residual air pressure should not be 10 For technical questions please call 1 800 444 3353 present after the tool is disconnected from the CO2 supply However it is a good safety measure to attempt to discharge the tool in a safe fashion after disconnecting to ensure that the tool is disconnected and unpowered As the contents of your CO canister are used up the available pressure will decrease Available pressure will eventually fall below your regulator setting The dial will show a lower pressure reading than desired When pressure is no longer adequate replace the CO Canister Dispose of used canisters according to solid waste disposal instructions To prevent accidents turn off the tool detach the CO Regulator from tool and canister and safely discharge any residual air pressure in the tool after use REV 09c Page 6 USER MAINTENANCE INSTRUCTIONS Procedures not specifically A explained in this manual must be performed only by a qualified technician 1 Detach tool and CO2 canister then clean external surfaces of the regula tor with clean dry cloth 2 Store the regulator indoors out of children s reach Note Since this regulator is not user serviceable no assembly diagram or parts

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`utilisation de la machine  クッキングプレートレシピ  Samsung 901B Manuel de l'utilisateur  Synology RS2211+ storage server  Fixed Network Camera Hardware User Manual  rapport d`enquête aéronautique a08w0244 impact sans perte de  講義資料3 - 岡山大学  SoftWall Finishing Systems SW973087010 Instructions / Assembly  USB Function Sample Code User`s Manual  VN-702PCm Enregistreur vocal numérique  