Home

Cascade Audio Engineering Power Supply 100 User's Manual

image

Contents

1. are not equipped with on off switches Do not plug the unit in until all connections are made Plug the AC input cord into a 120 volt three 3 wire grounded source APS 15 30 45 55 90 and 100 feature standard 3 prong grounded AC power cords The APS 75 is UL listed and is equipped with a polarized 20A male AC power plug per new UL code following photo left Polarized wall re ceptacles compliant with the new UL code for 20A circuits are available at your local electrical supply house see following photo right 6 Specifications 12VDC Cable Calculator MINIMUM wire gauge shown For MAXIMUM PERFORMANCE use LARGER wire gauge 3600 225 300 2700 150 225 1 0 GA 1800 125 150 1500 105 125 1260 85 105 1020 65 85 4 GA 780 50 65 600 35 50 420 20 35 240 0 20 8 GA WATTS AMPS 4 FT 4 7 FT 7 10 10 13 13 16 16 19 19 22 22 28 CABLE LENGTH 7 Available Accessories CAP 01 CAP 0 5 Cascade Audio Engineering also offers our CAP 1 One Farad and CAP 0 5 One Half Farad capacitors as well as our bolt on CAP DVM Digital Voltage Monitor Kit for the CAP 1 refer to photo below CAP Specifications Capacitance CAP 1 1 0 CAP 0 5 0 47 Farad 15 ESR 0 004 Ohms 20 Operating Voltage 20V Intended for 12V mobile applications Operating Temperature 95 Degrees Celcius Max HK 4 Hook Up Kit OurHK 4 Hook up Kit provides everything necessary to co
2. APS Power Supply 15 30 45 55 75 90 and 100 Amp Installation Guide Congratulations and thank you for purchasing a Cascade Audio Engineer ing APS Power Supply It is designed to provide years of efficient trouble free service All Cascade Audio Engineering APS power supplies feature regulated and filtered outputs that provide clean power without the slightest hint of noise The advanced circuitry utilized in our APS power supplies offer efficiency ratings of 86 90 Their super light weight 6 7 lbs low profile design allows for convenient mounting in or under a display vehicle car boat plane armored personnel carrier etc or behind a display board Your new APS power supply may be used with or without a battery How ever when combined with a high quality battery APS power supplies can supply transient surges up to 1000 amps In display applications where use of a battery are not possible installation of a Cascade Audio CAP 1 1 Farad or CAP 0 5 1 2 Farad capacitor is recommended APS power sup plies may also be connected in parallel for even higher current operation Because all APS Power Supplies utilize an advanced switching design there is no low frequency transformer hum Every power supply is equipped with a quiet running cooling fan When not in use APS Series Power Supplies are essentially off reducing electricity usage 1 Protection All Cascade Audio Engineering APS Power Supplies feature temperature
3. ce to provide unrestricted airflow in and around the unit Note Care must be taken to allow proper airflow when installing in an enclosed compartment Failure to provide proper airflow will result in poor performance or even product failure Never install electronics in a battery compartment or other area where flammable fumes may exist such as fuel storage areas Display Board Installation Mount the power supply to allow use of short positive and negative cables Use power distribution blocks if necessary Easy access to the main fuse or circuit breaker should be considered as well 2 Your new APS Power Supply can be used with or without an additional bat tery Use of a battery connected in parallel with your APS power supply will greatly increase the current available for transients For installations where use of a battery is not possible capacitors may be used Vehicle Installation Two methods of vehicle installation are commonly used One is to mount the positive and negative battery cables to the vehicle and to place the power supply under the vehicle when necessary Ease of connection is accomplished through use of an additional quick release type connector such as that provided with our HK 4 Hook up Kit see illustration below The other method is to mount the power supply permanently into the vehicle In this installation the power supply is hidden from view behind a panel in the vehicle A three prong male weatherproof rec
4. essed switchplate available from your local electrical supply house can be mounted to the bottom of the vehicle allowing use of a standard grounded outdoor extension cord to power the unit Installation of a manual reset circuit breaker in the positive cable between the power supply and the battery is recommended to prevent bat tery drain when the vehicle is stored for long periods of time without being plugged in DC Output Terminals Before making any connections be sure that the AC cord of your APS Power Supply is unplugged If installing a battery disconnect the positive side of the battery before installation Locate the two 2 screw terminals on the end of the APS Power Supply la beledPOS and NEG refer to the photo right 3 Cut the positive and negative cables that will go from the power supply to the load battery display board distribution blocks etc to the desired length Always use the proper sized cable based on the amperage of the power supply and the distance between the power supply and the load Please refer to the chart at the end of this manual Allow for proper routing of the cables Strip approx 1 of insulation from one end of each cable Insert the stripped end of the positive red cable into the POS terminal on the end of the power supply and the stripped end of the negative black cable into the NEG termi nal Firmly tighten the terminal screws Strip approx of insulation from the other end o
5. f the positive and negative cables terminate the ends as necessary and attach the cables to the load You may connect although not required for most installations the ground terminal to chassis or any other grounding source The grounding terminal is located close to one of the mounting tabs Note The gounding terminal is primarily used for RV installations If installing your power supply into an RV an additional cable as short as possible needs to go from this terminal to the chassis ground of the RV If ground loop noise is present a wire connected from the NEG terminal to the chassis ground connection may correct the condi tion Dual Voltage Switching The output voltage of any APS power supply Except APS 100 may be ad justed from 13 6 volts to 14 2 volts when necessary APS Power Supplies feature an RJ45 phone jack on the top of the unit located by the cooling fans see photo below left The unit is shipped with a jumper taped to the unit With the jumper removed the output is 13 6V With the jumper inserted the output is 14 2V Jumper wiring is shown in the following diagram right 4 Warning It is recommended that switching the output voltage on any APS power sup ply to 14 2 volts be done ONLY when rapid recharging of the battery is re quired Long term connection at the 14 2V output level will result in permanent battery damage Connecting Multiple APS Power Supplies APS power supplies may be connected in parallel
6. nnect an APS unit to a vehicle or display This pre assembled kit includes one 4ft length of black amp red 4ga cables pre terminated with ring connectors for the battery a heavy duty quick release connector and one 4ft length of black amp red 4ga cable to be terminated at the power supply DC outputs refer to photo at right Two Year Warranty Cascade Audio Engineering warrants its APS Power Supplies against any elec tronic or mechanical defects under normal use for a period of two 2 years from the date of original purchase If during the first year it is determined by Cascade Audio Engineering that the unit is defective it will be directly exchanged for a new unit If during the second year it is determined by Cascade Audio Engineering that the unit is defective it will be replaced or repaired at the discretion of Cascade Audio Engineering If an APS Power Supply fails for any reason please call Cascade Audio Engineering at 541 389 6821 Replacement units will be warranted for the remaining portion of the original warranty period If the power supply is out of warranty please call Cascade Audio Engineering at 1 541 389 6821 and arrangements will be made for the repair of the unit Please attach a letter with your name return address daytime phone number and a brief description of the problem When returning a unit to the factory pack the unit in its original packaging if at all possible If the original packaging i
7. overcurrent and reverse polarity protection circuitry They will provide stable regulated DC output voltage 13 6V or 14 2V relative to jumper connection The APS 100 is 13 4V only regardless of the load by varying output current to compensate AC input protection against damaging spikes of up to 190VAC and brown out input protection are also provided All APS Power Supplies feature an automatic thermally triggered current controlled fan APS 90 and APS 100 have two When the internal circuitry reaches a specified maximum operating temperature the fan will turn on The speed of the fan will vary with current draw In an overcurrent condition typically caused by use of an APS power Sup ply smaller than needed for a particular application APS Models 75 90 and 100 will automatically roll back current and voltage to prevent damage Full power will be restored when the overcurrent condition is corrected If an overcurrent condition is encountered with APS Models 15 30 45 and 55 and high current draw causes voltage to drop to approximately 2V the fuse on the end panel of the power supply will blow If the fuse blows repeatedly contact Cascade Audio for assistance All APS Power Supplies are protected against reverse polarity connection by use of internal diodes If the outputs are connected in reverse the fuse s will blow to protect the unit Mounting APS converter power supplies can be mounted in any position Allow suf ficient spa
8. s not available please pack the unit so that it will not be damaged in transit This warranty does not cover the installation or damage from abuse accident incorrect application misuse incorrect wiring water damage acts of God or operating the unit against instructed in these instructions This warranty does not cover any power supply that has been opened tampered with or altered in any way by anyone other than Cascade Audio Engineering It does not cover costs of installation or removal of the product or transportation to Cascade Audio Engi neering or damage in transit Cascade Audio Engineering shall not be liable for any special or consequential damages or for any other expenses incurred by reason of use or sales of this product This warranty is in lieu of any other warranties expressed or implied This warranty gives the consumer specific legal rights and they may have other rights which vary from stste to state Some states do not follow the exclusion or limitation of incidental or consequential damages the above exclusion may not apply Cascade Audio Engineering Tel 541 389 6821 Fax 541 389 5273 www cascadeaudio com 8
9. to increase their current capability There are a few important steps to follow 1 APS power supplies must only be connected to other APS units of the same model Example An APS 55 can ONLY be connected to other APS 55 power sup plies Failure to comply with this step will void your warranty 2 APS power supplies must be connected in parallel Positive to positive and negative to negative 3 It is possible to connect up to six 6 APS power supplies in parallel at one time Make sure the units are as close together as possible and that the power cables from the outputs are of equal length to provide maximum performance NOTE Make sure that the AC circuit is capable of the current required by multiple APS power supplies or damage may result Units larger than 55 amp need a dedicated circuit for EACH UNIT Please refer to the following diagram when connecting multiple APS Power Supplies up to a maximum of six Use of positive and negative distribu tion blocks is highly recommended 5 Fuses Your APS Power Supply is protected against reverse polarity If the battery or the APS unit is hooked up incorrectly the fuse on the end panel will blow and can easily be replaced When replacing fuses always use the same size AGC style fuses that came with your power supply The fuses are located next to the DC output terminals Refer to the picture below AC Input Cord All APS Power Supplies must be plugged into a 120V AC outlet They

Download Pdf Manuals

image

Related Search

Related Contents

LED スノードロップ  SPAN™ Technology for OEMV  iStarUSA WN368-EX racks  Manual de instalación Revolution fix Paso nº 1 Identifica la versión  XX kV  quick reference guide - The Shopping Channel  Electro-Voice PL5 User's Manual  INC GST - Normist Pty Ltd  Évacuation forcée - Giant Factories inc.  IAN 100052 - Lidl Service Website  