Home
Casablanca Fan Company 19th Century User's Manual
Contents
1. W 32 wall control unit INTELI TOUCH 4 SINGLE W 32 INSTALLATION CAUTION Ensure power is turned OFF at the breaker NEUTRAL or fuse panel before starting installation WHITE BLACK W 32 is used to describe either white 11 or ivory finish 1 Remove the screws and switch plate from the existing switch box 2 Remove the screws holding the switch in the switch box 3 Pull the existing switch from the switch box to expose the wire connections Remove the two wires from the switch 5 Connect the two wires just removed from the switch to the W 32 wall control black wire and black white stripe 2BLACKS CANOPY v GROUND 2 WHITES 2 GREENS tlh WIRE NUT SWAP THESE TWO WIRES WHEN wire Secure these connections with wire nuts NECESSARY 6 Install the W 32 in the wall box with the two long screws val Tue SEE NOTE BELOW provided h 7 Install the wall plate with the two color matched screws NOTE If your wall control operation is reversed i e fan switch controls lights and light switch controls fan simply swap the two W 32 black white stripe wires 120V AC BLACK WHITE FROM LIGHTS FROM LIGHTS BLACK INTELI TOUCH DUAL W 32 INSTALLATION CAUTION Ensure power is turned OFF at the breaker or fuse panel before starting installation To control the fan and lights from two locations a three way circuit use 2 W 32 wall controls 1
2. ceiling installations e This ceiling fan requires a grounded electrical supply of 120 VAC 60 Hz and a minimum 15 amp circuit The maximum current requirement for the fan with light fixture is 3 8 amps The fan uses about 1 amp or 100 watts Maximum light current is 2 8 amps or 340 watts of lighting Where wire nuts are employed be sure all bare wires are within the connectors When installing the canopy hatch make sure all wires are within the canopy and that no wires are being pinched For best performance and for your warranty to be valid use only genuine Casablanca blades light fixtures and accessories e The blades in each pack are matched for equal FUSE BOX weight to assure smooth fan operation If REMOVE FUSE FOR THE more than one fan is being installed be CIRCUIT YOU WILL BE careful not to mix blades from different WORKING ON cartons e Inspect the contents of your carton for possible shipping or handling damage and report any such damage directly to your authorized Casablanca dealer e Itis always a good idea to have an assistant to help with the installation e When cleaning painting or working near your fan be very careful of the fan and blades CIRCUIT BREAKER 84 Always turn the power OFF to the ceiling fan TRIP BREAKER FOR THE before servicing it working on it or replacing CIRCUIT YOU WILL BE light bulbs WORKING ON e Never insert anything into the path of the fan blades while the fan is in operation
3. shut off after two hours To cancel the Light Minder Program turn the off for three seconds INTELI TOUCH OPERATION 4 SAFE EXIT PROGRAM The Safe Exit Program gives you about thirty seconds of light when you turn the lights off enabling you to exit your home before the lights go out To enter the Safe Exit Program 1 Turn the off for at least three seconds 2 Turn the on 3 Immediately operate the buttons in the following sequence C FAN cP C FAN Pb C icht C LIGHT After you hear the confirming audio tones from the fan immediately press 4 The lights will blink to indicate this command has been accepted Note Both Light Minder and Safe Exit The lights will stay on for twenty seconds and then begin to dim After a programs can run at the same time total of thirty seconds has elapsed the lights will be off completely To however the dimmer cannot be used cancel the Safe Exit Program turn the off for three seconds the light may only be turned ON OFF INTELI TOUCH OPERATION HOME SAFE PROGRAM The Home Safe Program makes an unoccupied home appear occupied by turning the lights on and off at random times J To enter the Home Safe Program 1 Turn the off for at least three seconds 2 Turn the on 3 Immediately operate the buttons in the following sequence C LlGHT C FAN C UGHT FAN 4 A tone and flashing light indicate this command has been accepted This pro
4. 2 black white stripe wires Inteli Touch INTELI e TOUCH OPERATION 4 POWER The button is normally left in the on position Always turn the power off during cleaning or servicing the fan and during thunderstorms It RJ is also used to exit or enter additional programs POWER must be left on to retain a previously set fan speed or light level INTELI TOUCH OPERATION 4 SPEED CONTROL There are six individual speed settings for the fan each speed is indicated by an audible tone of increasing pitch FAN CONTROL To select the desired fan speed 1 With fan off press and hold the button labeled C FAN The fan blades ON OFF will start rotating at the slowest speed and will increase in steps A momentary press Tas 2 Release the button when the desired speed is reached of the FAN button aan The fan speed is now in memory and will automatically come on at the same bg speed each time the button is used To maintain this level of speed CHANGE SPEED turn the fan on by pressing less than one second To lower speed Press and hold FAN turn fan off then on by pressing and holding the button until the button longer than desired speed is reached When the fan is on you may increase the speed by one second pressing and holding the button until the desired speed is reached then release it INTELI e TOUCH OPERATION 4 REVERSING AIRFLOW The d
5. EW 2 FLAT WASHER 2 SUPPORT INSTALLATION PARTS CANOPY ADAPTOR PLATE es LARGE Y J FLAT WASHER 3 3 1 as LAG SCREW 3 3 7 X5 1 ADAPTOR PLATE I NSTALLATI ON Note After removing the old fixture check the outlet box to insure that it is supported by a joist or beam across its upper surface If not a 2 x 4 stud must be installed Step 1 Remove the knockout plug in the center of the outlet box or drill a 1 2 hole for the lag screw to pass through Then drill a 1 4 guide hole into the joist or beam to a depth of 3 CAUTION To reduce the risk of personal injury use only the mounting hardware provided with the approved outlet box to install the crossbar mounting bracket WARNING SUPPORT DIRECTLY TO BUILDING STRUCTURE ONLY X CEILING FAN APPROVED WIRING BOX WIRING CROSSBAR MOUNTI NG BRACKET 7 i gt GREEN FLAT 1 GROUND WASHER WIRE I I APPROVED OUTLET BOX HARDWARE as ABIA Ni e i k FAN ANGA LAG SCREW INSTALLATI ON Step 2 Route the outlet box wires through the 1 2 diam eter outer hole of the canopy adaptor plate Attach the crossbar and canopy adaptor plate to outlet box with screws provided Step 3 With the large washer attached pass the lag screw through the center hole of canopy adaptor plate and screw into guide hole Tighten until outlet box is firmly mounted to beam This box must
6. FAI e Never install a fan over a pool or spa ai CI i e Never operate a fan that has been damaged in any way Contact Casablanca Fan Company by calling 1 888 227 2178 or contact your local authorized Casablanca dealer for assistance in obtaining service P N 6943010 REV D P D NOVOOPDG FAN COMPANY MOUNTING RECOMMENDATIONS Before mounting your Casablanca fan read the following helpful recommendations The location of the fan air circulation and fan size are all important factors to consider before installation Location Ceiling fans have practical uses in almost every room in your home We suggest you follow these mount ing recommendations as you decide where to install your Casablanca fan e For safety reasons the fan blades must be a minimum of 7 above the floor e Do not locate the fan in a doorway or above a swinging door e In any installation the tips of the blades must be at least 18 from the wall in order to provide sufficient clearance for the blades e In bedrooms fans work best when mounted above the foot of the bed e Over pool tables be sure to provide plenty of clearance to avoid damage from pool cues e In kitchens be sure to allow for open cupboard doors to clear the fan blades K e Do not install a fan close to or over a pool or spa High humidity combined
7. Remove the screws and switch plate from the existing switch box and the screws holding the switch in the switch box 2 Pull the existing switch from the switch box to expose the wire connections 3 Determine which wire is connected to the com mon terminal of the 3 way switch The terminal will be marked on switch NEUTRAL v GROUND SWAP THESE TWO WIRES WHEN NECESSARY SEE NOTE BELOW BLACK 4 Remove the wire from the common terminal WITH ce BLACK of the 3 way switch Connect this wire to the BLACK WHITE remaining black white striped wire on the W PL STRIPE w 32 WHITE 32 control Secure this splice with a wire nut STRIPE STRIPE 5 Remove the two remaining wires from the 3 END IN way switch Connect one of these wires to a dE LINE black wire on the W 32 control Secure the BLACK splice with a wire nut The remaining wire is to be connected to the other black wire on the W 32 Secure the splice with a wire nut pack BLACK BLACK BLACK s 6 Install the W 32 in the wall box with the two long screws provided 120V AC 7 Install the wall plate with the two short color BLACK BLACK matched screws provided 8 Installation of the second W 32 control is iden tical Repeat steps 1 through 8 NOTE If your wall control operation is reversed i e fan switch controls lights and light switch controls fan simply swap the two W 3
8. SKET DOWNROD amp BALL ASSEMBLY INSTALL RUBBER GASKET Prepare the downrod as follows Step A Insert the small lip of the rubber gasket into the au LL MA ATTACH COVER TO DOWNROD Step B Slide the downrod cover rubber gasket first onto the CAUTION Do not attach the cover onto the downrod by using a twisting motion Continue until the rub downrod by pounding the downrod into the ber gasket is flush with the downrod ball floor This will damage the hanging mecha nism and may cause the fan to fall INSTALL METAL GASKET Step C Attach the metal gasket onto the downrod assembly as shown Using the provided screw secure the metal gasket Tighten the screw by hand only DUE LL LL FAN COMPANY esa FAN PREPARATION IMPORTANT SAFETY INFORMATION BEFORE STARTING THE INSTALLATION OF YOUR CEILING FAN INSTALL THE THREADED DOWNROD INTO THE MOTOR COUPLING AND LOCK THE ASSEMBLY Prepare for fan installation as follows Step D Route the wires from the motor through the PermaeLock downrod and ball assembly keeping the wires GROUND to one side of the cross pin MOTOR vane WIRES NOTE The downrod has a tapered thread that is designed to lock completely when DOWNROD correctly installed amp BALL ASSEMBLY Step E Using the provided allen wrench loosen the allen set screw Thread the downrod into the motor coupling until it stops turning this wil
9. TM 1 9TH CENTURY OWNER S MANUAL CONTENTS INTRODUCTION cits eit a ia da ee RS a CEC EE a 1 MOUNTING RECOMMENDATIONS ccc cece eee eee eee eee 2 PREPARATION INSTRUCTIONS ccc cece eects 3 FAN INSTALLATION ancii diodia nai winaa a iniciat de ed weal caca Gates aur acta Rl Wa aan ai 5 CONTROL FEATURES INTELI e TOUCH OPERATION ccc eee ee eee eee eee 12 TROUBLESHOOTING isc cici Ree hana Fae ne ee a ee Oii bwa 15 SAFETY FIRST Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product and proper installation therefore before attempting to install and operate your Casablanca fan read this owner s manual completely and carefully Retain this manual for future reference CAUTION To avoid possible electrical shock make certain that electricity is turned off at the circuit breaker or fuse box before attempting any installation procedure BEFORE YOU START e All wiring must be in accordance with the National Electric Code ANSI NFPA 70 1993 and the appropriate local electrical codes The National Electric Code requires proper grounding as a precaution against electrical shock A qualified electri cian should be consulted if you are unsure e This fan is designed to be installed on an existing electrical outlet box The outlet box must be UL Listed for ceiling fan installations if it is not a new box must be installed Casablanca extension poles are available for sloped or high
10. TY WALL CONTROL OPERATION IS INTER MITTENT Check AC supply for irregularities noise spikes fluctuations or failure or circuit board assembly For questions or to locate the nearest Casablanca Authorized Service Center call toll free 1 888 227 2178 or visit us on the web at www CasablancaFanCo com 761 Corporate CENTER DRIVE Pomona CA 91768 Toit Free 888 CASA 1ST 227 2178 www CasablancaFanCo com OCopYRIGHT 2000 CASABLANCA Fan COMPANY 2 U S PATENT PENDING PRINTED INROC
11. be firmly secured to the ceiling We recommend that the ceiling fixture outlet box be of suffi cient capacity enabling it to support the weight of fan and light fixture under any conditions 1 2 DIAMETER OUTER HOLE LARGE WASHER E CANOPY SCREW 4 O CANOPY LOCK WASHER 4 CANOPY HATCH CANOPY INSTALLATI ON Step 4 Attach the canopy to the crossbar mounting bracket behind the installed outlet adaptor plate with three of the 8 32 x 21 27 long canopy screws and lock washers provided with your Casablanca fan Hand tighten until snug against the ceiling Note On sloped ceilings align the canopy opening toward the top or peak of the room FEED OUTLET BOX WIRES THROUGH CANOPY OPENING 19 Century Step 5 To hang the fan body in the canopy hold the fan body firmly and insert the nylon ball into the canopy open ing Rotate fan body until slot on nylon ball fits into pin opposite canopy opening NOTE The fan weight is 35 pounds BALL CANOPY ELECTRICAL CONNECTIONS Step 6 Connect the fan wires to the outlet box wiring by placing the bare ends of the wires to gether and then securing with a wire nut Connect in this order e GREEN leads from mounting plate and fan to GROUND conductor of power source 2 WHITE WIRES Secure with wire nut e WHITE wire from fan to white NEUTRAL wire in ceiling fixture outlet box Secure with wire nut e BLACK wire from fan to black POWER wire
12. gram overrides all manual control of lights and fan The lights will now be automatically cycled on and off in a controlled sequence as follows On 1 hour off 1 2 hour on 2 hours off 1 hour on 2 hour then off 2 hours This seven hour pattern will repeat continuously so that a different pattern of r lighting is seen each day of the week A To cancel the Home Safe Program turn the off for three seconds INTELI TOUCH OPERATION 4 FAN MI NDER PROGRAM The Fan Minder feature will add to your comfort when used in the bedroom The program reduces the speed of the fan each two hour interval to compensate for the cooling night air To enter the Fan Minder Program 1 Turn the off for at least three seconds Turn the on Immediately operate the buttons in the following sequence Fan Minder A 2 3 Cuenr E FAN CO FAN STRONG AIRFLOW 4 The fan controller will respond with three descending tones A timer is now initiated and the fan Fan Minder B will reduce one speed for each two hour interval The fan will not however descend below the second lowest speed To cancel the Fan Minder Program turn the off for three seconds You may increase the fan speed by pressing and holding the button until the desired speed is reached then release it The fan will again reduce one speed for each 2 hour interval TROUBLESHOOTING z Inteli Touch Befo
13. h Series fan is an Auto A multi tone signal will verify the start of the test program matic Demonstration Program It can be used to fully which proceeds as follows I demonstrate and test the operation of the fan e Lights slowly increase to full intensity To enter the demonstration program ES i speed three with audio tones 1 Turn off for at least three seconds This will a N ese ani atura 2 Sa ay Eady for programming e Fan reverses at full speed with audio tones l 3 Immediately operate the buttons in the following se T A CES a ean EEES e Fan turns off with audio tones blades coast for a short FAN LIGHT FAN LIGHT FAN time GND 4 GGT D CEN L Get D C FN Lights turn off The complete cycle lasts slightly over one minute It will continue to repeat until the is turned off for more than three seconds cancelling the program Inteli Touch 0 OPERATIC DER PROGRA The Light Minder program automatically turns OFF the fan mounted lights after two hours To enter the Light Minder Program sA Z 1 Turn the OFF for at least three seconds Eta 2 Turn the ON s 3 Immediately operate the buttons in the following sequence C FAN C FAN C UGHT C LIGHT 4 A series of tones indicates this command has been accepted The fan and light will operate normally using the buttons to turn them on and off But if the lights are left on they will automatically
14. in ceiling fixture outlet box Secure with wire nut 2 BLACK WIRES 3 GREEN WIRES Inspect each wire nut and ensure that no bare WIRE NUT wire is visible pull on each wire to test the con nection is mechanically sound SS CANOPY HATCH INSTALLATION Step 7 Tuck the wires into the canopy with the wire nuts pointed upwards so that the WHITE and BLACK wires are on opposite sides of the canopy and all wires are clear of the canopy opening Step 8 Install canopy hatch with the last canopy screw and loch washer To do this tilt the fan body away from the hatch opening NOPY Tighten the screws firmly by hand only pai Step 9 Straighten the fan then chech ee 4 to ensure that there is no movement be tween the canopy and ceiling or Hang Tru LOCK AINSA ball and top support shaft WASHER S LAST CANOPY SCREW Note Write down the Serial Number and the model number for future CANOPY reference SCREW DISASSEMBLE CANOPY AND MOTOR COVERS Step 10 Remove the screws from the canopy cover and the motor cover and set aside for later use NSTALL CANOPY COVER Step 11 Take the two pieces of the canopy cover and assemble them around the downrod as shown Using the four screws removed in Step 10 assemble the canopy cover Slide the canopy cover to the ceiling and secure to the downrod using the two pro vided screws Tighten by hand only CAUTION The canopy c
15. irection of airflow can be changed from downward to Note A four toned signal indi sa upward or from upward to downward cates the command was accepted rers To reverse the airflow by the fan A fem seconds later REVERSE 1 Make sure the 15 ON the fan will slow to a stop and FR D 2 Press the button then reverse direction INTELI TOUCH OPERATION 4 LIGHT To turn the lights off and on press and release the button for less LIGHT CONTROL than one second To vary the light brightness ON OFF 1 With lights off press and hold the button After one secondthe momentary press of NI lights come on at their lowest level and gradually become brighter the LIGHT button im 2 Release the button when the desired brightness level is reached Ge The brightness level is now in the fan memory and will automatically come CHANGE BRIGHTNESS a on at the same brightness the next time the button is used To PRESS AND HOLD hd maintain this level of brightness press the button for less than LIGHT BUTTON one second To lower the brightness turn the lights off then press and hold LONGER THAN ONE the button until the desired brightness level is reached When the SECOND light is on you may increase the brightness level by pressing and holding the button until the desired level is reached then release it AUTOMATIC DEMONSTRATION PROGRAM Programmed into every Inteli Touc
16. is turned off during this inspection FAN WOBBLES OR SHAKES EXCESSIVELY Be sure canopy pin is properly set into the slot on the ball Check the screws holding the blade holders to the fan motor Tighten as necessary Check the angle of the blades to make sure that a blade holder has not been bent during installation FAN NOISY DURING OPERATION Check and tighten light fixture retaining screws glass shade screws and or the light bulb s Tighten canopy screws and mounting plate assembly Tighten the blade to bladeholder screws and blade holders to flywheel Make sure all screws in the motor housing are snug but not overly tight Check that the wire nuts inside the canopy and switch housing are not touching the metal parts or have fallen off the wire splices Tighten or adjust as necessary BREAK IN PERIOD DOES NOT RUN ON LOW SPEED Let fan run at high speed for two 2 hours If new break in may be required run at higher speed for several days LIGHTS FLASH OR BLINK DURING OPERATION OF W 32 WALL CONTROLS FAN MAY ROTATE OR MAKE AUDIBLE TONES DURING OPERATION OF THE W 11 AND W 12 WALL CONTROLS Normal operation WHEN AC POWER IS TURNED ON FOR THE FIRST TIME THE LIGHTS OPERATE NORMALLY BUT W 32 WALL CONTROL OPERATION IS REVERSED FAN BUTTON OPERATES THE LIGHTS LIGHT BUTTON OPERATES THE FAN Reverse the 2 black and white striped wire connections FAN OR LIGHTS APPEAR TO OPERATE BY THEMSELVES CHANGING SPEED OR INTENSI
17. l take at least four and a half full turns Step F Securely tighten the allen set screw with the provided allen wrench to ensure safe operation of your fan CAUTION Failure to fully lock in the down rod before securely tightening the locking bolt may cause the fan to fall during nor mal operation ALLEN SET SCREW Yq 20 x Va PRE INSTALLED TAPERED THREAD ALLEN CG MOTOR SET SCREW COUPLING 0 ALLEN WRENCH GETTING STARTED Installing a New Ceiling Fixture Outlet Box Using Existing Ceiling Fixture Outlet Box If you do not have an existing fixture located where you wish After turning the power OFF at its source either circuit breaker to place your Casablanca fan an approved ceiling fixture or fuse box lower the old fixture and disconnect the wiring outlet box must be installed and wired Check the ceiling fixture outlet box to be sure that it is marked Approved for ceiling fan mounting If it is not a new Warning To reduce the risk of fire electrical shock Bori Ebe ne or personal injury mount to outlet box marked ac ceptable for ceiling fan support using the mounting hardware provided with the outlet box NOTE The fan weight is 35 pounds CROSSBAR WIRE NUT 4 MOUNTING BRACKET 19 Century CEILING HARDWARE ADDITIONAL HARDWARE 21 4 x 8 32 ROUNDED mm HEAD SCREW 2 humm 2 X 8 32 ROUNDED HEAD SCR
18. over can NOT be used on sloped ceilings SCREWS FROM PROVIDED _ _ SCREWS Step 12 Take the two pieces of the mo tor cover and assemble them around the downrod as shown Using the two screws removed in Step 10 assemble the motor cover Slide the motor cover down onto the top of the fan and secure to the downrod us ing the two provided screws Using the screwdriver tighten securely by hand only SCREWS FROM STEP 10 19 Century BLADE HARDWARE BLADE BLADE q SCREW WASHER BLADE HOLDER ATTACH BLADE HOLDERS Step 13 Attach the blades to the blade holders by align ES Le ing the screw holes of the holder with the holes of the 8 Ba blade H se ON BLADE Attach the blade holder using the four blade screws and WASHER blade washers provided for each blade Using the screwdriver tighten securely by hand only x INSTALL BLADE ASSEMBLY Step 14 Remove the blade holder screw from the fan Slide the blade assembly into the cross bar assuring that the alignment holes line up Reinstall the blade holder screw making sure that the BLADE blade assembly is secure and does not rotate when turned HOLDER SCREW Using a wrench or pliers tighten securely by hand only ALIGNMENT ALIGNMENT PIN BLADE HOLDER SCREW BLADE ASSEMBLY Qe FAN COMPANY LIGHT KIT WIRING NOTE If you do not desire to install the light kit see O
19. plate card inserted in the straight down It is OK to install your back of this manual it provides you with a simple go or fan no go for installing your fan on a sloped ceiling EXAMPLE 3 Your fan will not hang straight down an ls The Sa ee Cancer an adaptor is necessary Contact your local e usea on a stoped ceiung Authorized Casablanca Dealer in regards to purchasing a Slope Ceiling Adaptor g EXAMPLES This slope is more than 32 19 Century PREPARATION INSTRUCTIONS Unpacking Before assembling and installing your ceiling fan remove all parts from the shipping cartons and check them against the parts listed here Before discarding packaging material be certain that all parts have been removed GETTING STARTED Carton Contents The fan carton contains the fan body warranty card owner s Be sure to use only genuine Casablanca blades The blade manual and all the parts necessary to assemble and install your shrink wrap holds 4 blades of matched weight If more than Casablanca ceiling fan These parts are shown at the start of one fan is being installed be sure not to mix blade sets each installation section Before you start go through this Owner s Manual and confirm that you have all the parts shown CAUTION When removing the shrink wrap in each section be careful not to scratch the blades PERMA LOCK HARDWARE Cera e S DOWNROD COVER RUBBER DOWNROD METAL DOWNROD GASKET GA
20. ptional Switch Housing Cup installation instructions on Page 11 Step 15 Remove the wire nuts on the BLACK and WHITE wires from the fan If necessary re move the insulation from the last 1 2 of each wire fan and light fixture Step 16 Attach the switch housing wires to the light fixture wires by placing the bare ends of the wires together and then securing with a wire nut Connect in this order e WHITE wire from fan to WHITE wire from light fixture Secure with wire nut e BLACK wire from fan to BLACK wire from light fixture Secure with wire nut Inspect each wire nut and ensure that no bare wire is visible pull on each wire to test the connection is mechanically sound WIRE NUT INSTALL LIGHT KIT Step 17 Slide the light kit over the threaded pipe from the switch housing Assure that no wires are pinched Secure the light kit to the fan with the finial Tighten securely by hand only ae E E CA THREADED PIPE FINI AL 60 WATT TYPE A15 INCANDESCENT BULB GLASS HARDWARE GLASS SHADE GLASS amp BULB INSTALLATION Step 18 Loosen the three glass screws for each fixture so the end of the screws are flush with the inside of the fixture Slide the glass shade into the fixture and hold firmly Turn each screw several times going in a circle to assure that all glass screws have en gaged the glass Tighten securely by hand only Step 19 Ins
21. re Requesting Service Please follow this troubleshooting guide before contacting your dealer for assistance Caring for Finishes For cleaning a soft brush or lint free cloth should be used to prevent scratching the finish A vacuum cleaner brush nozzle can remove heavier dust Surface smudges or an accu mulation of dirt and dust can easily be removed by using a mild detergent and slightly dampened soft cloth An antistatic agent may be used but never use abrasive cleaning agents These will damage the finish Painted and high gloss blades may be cleaned in the same manner Blades Wood finish blades should be cleaned with a furniture pol ishing cloth Occasionally a light coat of furniture polish may be applied for added protection and beauty Never Lubricate this Fan The precision motor at the heart of your Casablanca fan features sealed bearings that are lubricated for life Do not attempt to oil the motor Changing Light Bulbs Be sure to turn power to the fan OFF at the wall switch or circuit breaker before changing light bulbs Replace bulbs with same type as removed from the fixture Each fan is rated for a maximum TOTAL wattage of lighting Exceeding the rated maximum allowable wattage for the fan will burn out the fan electronics module and void the warranty PROBLEM POSSIBLE REMEDI ES NO FAN OR LIGHT Check main circuit fuses circuit breakers or wall switch position Check all wire connections making sure the power
22. tall the four 60 Watt type A15 bulbs into each fixture CAUTION TO REDUCE THE RISK OF FIRE USE MAX FOUR 60W STANDARD BASE A15 INCANDESCENT LIGHT BULBS Note Do NOT use standard A 19 bulbs This commonly available size is too large in diameter the proximity of the bulb to the glass will not allow for adequate air circulation GLASS SHADE SCREWS GLASS SHADE 60 WATT TYPE A15 INCANDESCENT BULB OPTIONAL SWICH HOUSING CUP NOTE This step is ONLY performed if you have chosen NOT to install the light kit Slide the optional switch housing cup over the threaded pipe from the switch hous ing Assure that no wires are pinched Secure the cup to the fan with the finial Tighten securely by hand only OPTIONAL SWITCH HOUSING CUP THREADED el 9 FINI AL IntelieTouch 0 O i i J RU The wall control installs in the same manner as an ordinary light switch using an existing junction box and wiring This controller is designed to signal the fan microcomputer as well as perform normal switching operations For this reason the following precautions must be observed 1 Use only the Casablanca W 32 wall control 3 Do not use more than one fan per wall control 2 Do not use any additional control with your Inteli Touch 4 No other light fixtures or electrical appliances may be con fan for example dimmer fan speed control etc nected on the circuit controlled by the
23. with os corrosive gases will destroy the finish and warp the blades DINING ROOM Fan Size Variable fan speed capability permits the use of a full size 52 fan even in smaller rooms For very large rooms two fans may be needed SLOPED CEILING INSTALLATIONS MAXIMUM HANG TRU ANGLE 322 Suggested Extension Pole Lengths Ceiling Height Pole Length 10 Standard 11 18 12 24 13 36 14 48 BLADES MUST BE A MINIMUM OF 7 ABOVE THE FLOOR When to Use Extension Poles For best performance and best appearance an extension pole should be used with 7 MINIMUM your Casablanca fan when installing on high cathedral ceilings or sloped ceil ings Casablanca offers standard poles in IP increments of 67 up to 5 Custom poles are available in lengths up to 10 See your ANZ Authorized Casablanca Dealer for details AZ Note Fan may wobble or vibrate if Ale pole length is not long enough and inside blade is too close to downslope or side wall Extending pole length will usually solve problem Tens less than 32 It is OK to install your fan EXAMPLE 2 A i Thi is 32 This is the maximum Calculation of 32 i I 3 Ar will allow the fan to hang Use the tear off Ceiling Angle Tem
Download Pdf Manuals
Related Search
Related Contents
Verdero VF80 User's Manual WSE-6100 ルミノグラフ (LuminoGraph) Sander Ponceuse Esmeriladora Angular 3 - Bürgerstiftung Lebensraum Aachen Mod. Panther21 DPoETM Power Patch Panel Módulo de mando BM Instrucciones de montaje a Engineer To Engineer Note EE-115 SOYO AVRO3001 User's Manual Copyright © All rights reserved.