Home

Cadet CBC103TW User's Manual

image

Contents

1. LISTED Profundidad P Configuraciones de multivoltaje de 1 2 120 6 240 voltios de CA 1000 vatios Fijado en fabrica en 240 voltios HERRAMIENTAS NECESARIAS Cuchillo multiuso Destornillador Phillips 4 tornillos de 1 para madera Destornillador plano Conectores de alambre aislados MODELOS Pelacables 1 conector de alivio de tension CBC103TW or CB103T The Com Pak Bathroom Heater INSTRUCCIONES IMPORTANTES N ADVERTENCIA g ADVERTENCIA MLM Desconecte la electricidad en el tablero del panel NO lo instale donde el calentador se pueda mojar el ctrico caja de cortacircuitos o fusibles y trabe o coloque un cartel en la puerta del tablero del panel 10 N ADVERTENCIA para evitar que alguien vuelva a conectar la energ a El calentador se debe conectar a un circuito derivado con mientras se est trabajando en el calentador De lo protecci n GFCI contrario podr an producirse graves golpes el ctricos quemaduras e incluso la muerte 11 AN ADVERTENCIA 1 Lea todas las instrucciones antes de usar este calentador Riesgo de quemaduras Este calentador se calienta mucho cuando est en uso Para evitar quemaduras no lo toque con su piel descubierta Tenga mucho cuidado al utilizar cualquier tipo de calentador en presencia de ni os o personas inv lidas 2 Lea todas las etiquetas que contengan informaci n Verifique que todos los cables de suministro el ctrico sean del mismo voltaje que el calentador 3 Todo tr
2. The Com Pak Bath Heater 10 Width 25 4cm 7 12 5 8 Height 32 07cm LISTED Lec TOOLS REQUIRED Phillips Screwdriver Straight Screwdriver Wire Strippers Utility Knife 4 11 2 Wood Screws Insulated Wire Connectors 1 Strain Relief Connector SAFETY amp QUALITY The Com Pak Bath Heater OWNER S GUIDE FOR MULTI VOLT MODELS Features Benefits m Thermal safeguard e High temperature manual reset turns off heater if normal operating temperatures are exceeded Commercial grade steel element painted to resist rusting E Built in controls Single pole thermostat with disabled no heat position 60 minute timer overrides thermostat for instant warmth E Powder coat paint process eliminates sharp cutting edges m Three year extended warranty on element and motor E Factory tested E Multi Volt configurations 120 or 240 Volt AC 1000 Watts Factory set at 240 Volts Models CBC103TW or CB103T The Com Pak Bathroom Heater IMPORTANT INSTRUCTIONS N WARNING Turn the electrical power off at the electrical panel board circuit breaker or fuse box and lock or tag the panel board door to prevent someone from turning on power while you are working on the heater Failure to do so could result in serious electrical shock burns or possible death 1 Read all instructions before using this heater 2 Read all information labels Verify that the electrical supply wires are the sam
3. sin calor TE Presione los cables hasta el fondo de la c mara de pared durante la inserci n Cerci rese de que los alambres de suministro no queden atrapados entre el motor y la c mara de pared fije el conjunto en la parte superior con el tornillo suministrado WNC Instale la rejilla Fije la rejilla con los tornillos suministrados Deslice la perilla del termostato en el eje del control derecho extendi ndola por la rejilla y la perilla del temporizador en el eje izquierdo Conecte la alimentaci n en el tablero del panel el ctrico ES My YU Coy a OREJETA al calentador aun cuando ste parezca no estar funcionando Si no se siente comodo al trabajar con artefactos el ctricos no esta en condiciones de acatar estas pautas o no cuenta con los equipos necesarios solicite los servicios de un t cnico electricista calificado 3 Una vez que verifique que se ha apagado la alimentaci n correctamente prosiga con el paso siguiente 4 Retire los tornillos y extraiga la rejilla 5 Lave la rejilla con agua caliente y jab n y s quela de inmediato 6 Mientras sujeta la rueda del soplador para evitar que se da e o tuerza utilice una secadora o una aspiradora en el ciclo de soplado para quitar la suciedad en el elemento superior sin tocarlo 7 Aspire el rea del ventilador sin tocar los elementos 8 Vuelva a instalar la rejilla y fijela con los tornillos 9 Coloque el termostato
4. El calentador de ba o Com Pak est configurada para operar a 240 voltios de manera predeterminada SUMINISTRO DE ALIMENTACI N DE 240 VOLTIOS Figura 5 TERMINAL LIBRE EN LA BARRA DE ACORTOCIRCUI TO DEL ELEMENTO 6 PUENTE CON DESC gt dad R P AISLADA y TEMPORIZADOR TERMOSTATO L J B CALENTADOR AISLADO DE DESCONEXION RAPIDA INTERRUPTOR LIMITE DE ALTA TEMPERATURA DE REGLAJE MANUAL Alambre Blanco m Y Alambre Rojo j Alambre Negro Alambre Azul Para la configuraci n de 120 voltios A fin de configurar el calentador para 120 voltios desconecte el alambre azul del terminal D y con ctelo al terminal A Luego conecte el alambre rojo suelto al terminal D SUMINISTRO DE ALIMENTACI N DE 120 VOLTIOS Figura 6 TERMINAL PUENTE CON TEMPORIZADOR TERMOSTATO DESC RAP 6 AISLADA EDO AISLADO DE DESCONEXI N R PIDA INTERRUPTOR DE REGLAJE MANUAL Alambre Azul Alambre Blanco AN ADVERTENCIA Desconecte la electricidad en el tablero del panel el ctrico caja de cortacircuitos o fusibles y trabe o coloque un cartel en la puerta del tablero del panel para evitar que alguien vuelva a conectar la energ a mientras se est trabajando en el calentador De lo contrario podr an producirse graves golpes el ctricos quemaduras e incluso la muerte ADVERTENCIA Riesgo de electrocuci n Conecte el conductor a tierra al tornillo de puesta a tierra suministrado
5. Evite que entren objetos extra os al calentador ADVERTENCIA Riesgo de incendio El calentador debe mantenerse sin obstrucciones un m nimo de 3 pies por delante 6 pulgadas en cada costado y por encima Los calentadores deben mantenerse sin pelusas suciedad ni residuos 10 Instrucciones para la instalacion C mo se coloca la unidad del calentador en la camara de pared ISE Instale la unidad del calentador Voltee la unidad del calentador dejando en frente suyo el elemento situado bajo el motor Empalme los cables de suministro con los del calentador mediante conectores consulte la figura 9 Ahora gire el calentador de modo que el elemento y el ventilador queden frente a usted El elemento debe quedar arriba Inserte el borde inferior de la unidad del calentador en las ranuras semicirculares del reborde inferior en La garant a pierde su validez si se roc a alg n producto en el elemento o en el soplador C mo hacer funcionar el calentador 1 Una vez que se haya realizado la instalaci n y reestablecido la energ a el ctrica gire totalmente la perilla del termostato en el sentido de las manecillas del reloj El termostato est a la derecha 2 Cuando la habitaci n haya alcanzado un nivel c modo gire la perilla del termostato en sentido contrario a las manecillas del reloj hasta que el calentador se apague El calentador se encender y apagar autom ticamente seg n esta tem
6. de pared en la abertura manteni ndola alineada con la superficie de la pared Asegure la c mara al puntal de la pared con 2 tornillos mediante los orificios que vienen en la c mara Contin e con la PARTE DOS Contin e con la PARTE DOS Instrucciones para la instalaci n Parte Dos Configuraci n de cableado del elemento de multivoltaje Consulte las figuras 5 6 7 y 8 seg n el voltaje que desee LEI Determine el voltaje del suministro El calentador se debe conectar a un circuito derivado con protecci n GFCI Antes de instalar el calentador es extremadamente importante verificar que est configurado para el voltaje de suministro correcto El calentador de ba o Com Pak est configurado de manera predeterminada para funcionar a 240 voltios Para la instalaci n a 120 voltios se debe reconfigurar el cableado del calentador Instalar el calentador sin configurarlo para el voltaje correcto destruir el aparato e invalidar la garant a C mo determinar el voltaje de suministro Si va a reemplazar un calentador existente revise las etiquetas del calentador antiguo y sustit yalo por otro del mismo voltaje Para una construcci n nueva los alambres del calentador se deben configurar de modo que coincidan con el voltaje de los alambres del suministro del inmueble Si necesita ayuda consulte a un t cnico electricista calificado ZE Seleccione el voltaje adecuado del calentador Para la configuraci n de 240 voltios
7. do insert the heater assembly into the wall can Install Heater Assembly Turn heater assembly upside down element down with motor facing you Connect the supply wires to the heater wires with connectors See Figure 9 Now rotate the heater so the element and the fan are facing you The element should be at the top Insert the bottom edge of the heater assembly into the half round slots in the bottom lip of the wall can See Figure 10 IMPORTANT Push wires into bottom of wall can during insertion Be sure that supply wires are not Warranty is void if any material is sprayed on the element or blower How to operate your heater 1 Once installation is complete and power has been restored turn the thermostat knob fully clockwise The thermostat is on the right 2 When the room reaches your comfort level turn the thermostat knob counterclockwise until the heater turns off The heater will automatically cycle around this preset temperature 3 To reduce the room temperature turn the knob counterclockwise To increase the room temperature turn the knob clockwise 4 For additional heat beyond thermostat setting when room Is occupied turn timer to desired minutes The timer is on the left and represented by the symbol The numbers indicate minutes Heater will remain on until time expires then control of the heater will return to the thermostat and the previous set point setting Maintenance As needed or every
8. instale un calentador de mayor vatiaje o m ltiples calentadores si fuese necesario Si su circuito es apto para mayor capacidad Espere que el temporizador termine su per odo o bien g relo en sentido contrario a las manecillas del reloj a 0 el temporizador supedita el ajuste del termostato Si el calentador contin a funcionando f jelo en el ajuste m nimo Si el calentador contin a funcionando espere un poco para que el termostato tenga tiempo de responder al ajuste el termostato se debe reemplazar Limpie el calentador consulte las instrucciones en la secci n Funcionamiento y Mantenimiento Debe reemplazarse el calentador o el motor del ventilador Quite la obstrucci n y oprima el bot n de reglaje del calentador despu s de dejar que la unidad se enfr e Pruebe el funcionamiento del calentador si el bot n de reglaje se ha oprimido aseg rese de escuchar y de sentir un chasquido indicando que se ha restablecido pero el calentador no funciona el calentador debe repararse o reemplazarse Ajuste el termostato a una temperatura m s alta hasta que el calentador funcione vea el Problema No 5 si la dificultad persiste 3 Hay un cortocircuito en los cables de suministro o del calentador 4 Cortacircuito defectuoso 1 Temperatura insuficiente del elemento calentador funciona pero 2 Voltaje de suministro incorrecto no env a aire caliente 3 El elemento ha fallado El calentador no se apag
9. se est trabajando en el calentador De lo contrario podr an producirse graves golpes el ctricos quemaduras e incluso la muerte Tabla de resoluci n de problemas CONSULTE LOS C DIGOS EL CTRICOS LOCALES PARA DETERMINAR QU TRABAJOS DEBEN SER REALIZADOS POR PERSONAL DE SERVICIO EL CTRICO CALIFICADO S ntoma Problema Solucion El interruptor se disyunta 1 Voltaje de suministro incorrecto 1 Compruebe que el voltaje de suministro coincida con la calificaci n del calentador inmediatamente al 2 Circuito sobrecargado 2 El amperaje total de todos los calentadores en un circuito de rama no debe sobrepasar encenderse el calentador el 80 de la calificaci n de amperaje del cortacircuito y de las calificaciones de los cables de suministro Utilice un calentador de vatiaje inferior o reduzca la cantidad de calentadores en el circuito Los cables de suministro o del calentador que presentan cortocircuitos pueden ocasionar chispas peligrosas Revise el aislamiento de todos los cables de suministro y del calentador para comprobar que no est n da ados No reestablezca el cortacircuito sino hasta que se hayan reparado todos los cortocircuitos el ctricos Reemplace el cortacircuito Espere unos momentos para que el elemento alcance la temperatura de funcionamiento Compruebe que el voltaje de suministro coincida con la calificaci n del calentador Reemplace el elemento Cierre las puertas y ventanas Coloque aislamiento adicional o
10. un destapadero y coloque el cable de suministro mediante un conector de alivio de tensi n dejando 10 pulgadas de cable de conexi n para utilizarlo m s adelante Conecte el alambre de suministro a tierra al cable espiral de puesta a tierra situado en la c mara de pared consulte la figura 3 Contin e con la PARTE DOS CABLE DEL SUMINISTRO DESTAPADERO GIRE PARA RETIRARLO CONECTOR DE ALIVIO DE TENSION a TORNILLO 24 DE PUESTA Lt A TIERRA Figura 3 C mo se instala el calentador en una pared existente EZAN Corte un orificio en la pared Corte un orificio de 8 pulgadas de ancho por 10 de alto al lado de un puntal de la pared Este calentador REQUIERE UNA DISTANCIA M NIMA de 6 pulgadas de las superficies murales adyacentes y 4 pulgadas del piso Sin embargo Cadet RECOMIENDA 12 pulgadas desde todas las superficies murales adyacentes y 12 pulgadas desde el piso consulte la figura 4 PARED ADYACENTE Figura 4 Model CB IZ Conecte los alambres de suministro Tienda el cable de suministro desde el cortacircuito directamente al calentador Quite un destapadero y fije el cable de suministro mediante un conector de alivio de tensi n dejando 10 pulgadas de cable de conexi n para utilizarlo m s adelante consulte la figura 3 Empalme el cable de conexi n a tierra del suministro al tornillo de puesta a tierra que viene en la c mara de pared SER Montaje de la c mara de pared Inserte la c mara
11. a 1 La fuga de calor de la habitaci n es superior a la capacidad del calentador El ventilador del 2 El termostato no funciona correctamente El calentador emite humo 1 Se han acumulado polvo pelusas u o un olor a quemado otros materiales dentro del calentador El elemento calienta por 1 Motor o conexi n interna defectuosos un momento sin que gire 2 Ventilador o motor trabado el ventilador y luego deja de calentar 1 El termostato est fijado muy bajo o bien en la posici n de inhabilitaci n sin calor 2 El calentador ha hecho saltar el interruptor de reglaje de alta temperatura 3 La energ a no est conectada en el cortacircuito 4 El o los cables que van al calentador est n rotos o mal conectados 5 Termostato y o temporizador defectuosos 1 Se han acumulado polvo pelusas u otros materiales dentro del calentador 2 El flujo de aire est bloqueado El calentador no funciona Oprima el bot n de reglaje manual vea las instrucciones en la secci n Funcionamiento y Mantenimiento Conecte el cortacircuito correcto en el panel principal Desconecte la energ a en el cortacircuito Revise la continuidad del cable de suministro y la conexi n apropiada a los cables del calentador Repare o reemplace el calentador Se debe revisar la continuidad de todo el calentador o bien de sus componentes a fin de determinar la causa de cualquier problema Limpie el calentador vea las instru
12. abajo y materiales el ctricos deben cumplir con el 12 N ADVERTENCIA C digo El ctrico Nacional NEC por su sigla en ingl s Riesgo de electrocuci n NO instale el calentador directamente con la Ley de Seguridad y Salud Ocupacional OSHA por sobre la tina o lavamanos NO lo instale en la zona de la su sigla en ingl s y con todos los c digos estatales y locales ducha el fabricante recomienda un espacio m nimo de 2 pies 4 Conecte el tornillo de puesta a tierra que viene en la c mara de pared al cable de conexi n a tierra del suministro 5 Sise debe instalar un nuevo circuito o se necesita informaci n adicional sobre el cableado consulte a un electricista calificado 13 ADVERTENCIA Riesgo de electrocuci n Conecte el conductor a tierra al tornillo de puesta a tierra suministrado Evite que entren objetos extra os al calentador 6 Evite que los cables de suministro el ctrico se retuerzan 14 N ADVERTENCIA o entren en contacto con objetos afilados aceite grasa Riesgo de electrocuci n Nunca coloque un interruptor donde superficies calientes o sustancias qu micas pueda ser alcanzado por el conjunto de la tina o ducha 7 AN ADVERTENCIA 15 N ADVERTENCIA Podr a producirse sobrecalentamiento o un incendio NO Riesgo de incendio No bloquee el calentador El calentador instale el calentador en el suelo cielo raso o detr s de puertas debe mantenerse sin obstrucciones un m nimo de 3 pies 8 A N ADVERTENCIA
13. ating it has been reset but heater does not run heater requires repair or replacement Adjust thermostat to a higher temperature until heater operates See Problem 5 if the problem persists Press the manual reset button See Operation amp Maintenance section for instructions Turn on the correct circuit breaker in the main panel Turn off power at circuit breaker Check supply wire continuity and proper connection to heater wires Repair or replace the heater The entire heater or any of its components may be checked for continuity to determine the cause of any problem Clean heater See Operation amp Maintenance section for instructions Remove obstruction Maintain a minimum distance of 6 inches from adjacent surfaces 4 5 inches from the floor and 3 feet for furniture or other objects placed directly in front of the heater Remove obstruction and press heater manual reset button See Operation amp Maintenance section for instructions 4 Replace heater assembly LIMITED ONE YEAR WARRANTY Cadet will repair or replace any Cadet product including thermostats found to be defective within one year after the date of purchase Extended Product Warranty LIMITED THREE YEAR WARRANTY Cadet will repair or replace any Com Pak Bathroom Heater CB series element or motor found to be defective or malfunctioning from first date of purchase through the third year These warranties
14. cciones en la secci n Funcionamiento y Mantenimiento Retire la obstrucci n Mantenga una distancia m nima de 6 pulgadas de las superficies adyacentes 4 5 pulgadas del piso y 3 pies de los muebles u otros objetos situados directamente delante del calentador Retire la obstrucci n y oprima el bot n de reglaje manual del calentador vea las instrucciones en la secci n Funcionamiento y Mantenimiento Reemplace el conjunto del calentador El calentador disyunta continuamente el control limitador de temperatura de reglaje manual 3 El ventilador o el motor est trabado 4 Ninguna de las anteriores GARANT A LIMITADA DE UN A O Cadet reparar o reemplazar todo producto Cadet incluyendo los termostatos que presente aver as en un plazo de un a o a partir de la fecha de compra Garant a extendida del producto GARANT A LIMITADA DE TRES A OS Cadet reparar o reemplazar todo calentador de ba o Com Pak CB que se determine que est averiado o funcionando mal durante tres a os a partir de la fecha de compra ESTAS GARANTIAS NO SON PERTINENTES PARA Da os que sufra el producto por instalaci n o voltaje de suministro incorrectos Da os que sufra el producto por mantenimiento incorrecto uso indebido abuso accidente o alteraciones Servicio que se le haya dado al producto por parte de personas o entidades ajenas a Cadet Casos en que no se pueda determinar la fecha de fabricaci n de
15. do not apply 1 Damage occurs to the product through improper installation or incorrect supply voltage 2 Damage occurs to the product through improper maintenance misuse abuse accident or alteration 3 The product is serviced by anyone other than Cadet 4 If the date of manufacture of the product cannot be determined 5 If the product is damaged during shipping through no fault of Cadet 6 CADET S WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT AS SET OUT HEREIN CADET SHALL NOT BE LIABLE FOR DAMAGES SUCH AS PROPERTY DAMAGE OR FOR CONSEQUENTIAL DAMAGES AND OR INCIDENTAL EXPENSES RESULTING FROM BREACH OF THESE WRITTEN WARRANTIES OR ANY EXPRESS OR IMPLIED WARRANTY IN THE EVENT CADET ELECTS TO REPLACE ANY PART OF YOUR CADET PRODUCT THE REPLACEMENT PARTS ARE SUBJECT TO THE SAME y WARRANTIES AS THE PRODUCT THE INSTALLATION OF REPLACEMENT PARTS DOES NOT MODIFY OR EXTEND THE UNDERLYING WARRANTIES REPLACEMENT OR REPAIR OF ANY CADET PRODUCT OR PART DOES NOT CREATE ANY NEW WARRANTIES 8 These warranties give you specific legal rights and you may also have other rights which vary from state to state Cadet neither assumes nor authorizes anyone to assume for it any other obligation or liability in connection with its products other than as set out herein If you believe your Cadet product is defective please contact Cadet Manufacturing Co at 360 693 2505 during the warranty period for instructions on how to have the repa
16. e voltage as the heater 3 All electrical work and materials must comply with the National Electric Code NEC the Occupational Safety and Health Act OSHA and all state and local codes 4 Connect the grounding screw provided in the wall can to the supply ground wire 5 If you need to install a new circuit or need additional wiring information consult a qualified electrician 6 Protect electrical supply from kinks sharp objects oil grease hot surfaces or chemicals 7 A WARNING Overheating or fire may occur DO NOT install the heater in a floor in the ceiling below a towel bar behind a door or anywhere the air discharge may be blocked in any manner 8 A WARNING Fire or explosion may occur DO NOT install heater in any area where combustible vapors gases liquids or excessive lint or dust are present 9 WARNING DO NOT install where heater is likely to get wet 10 4 WARNING Heater must be connected to a GFCI protected branch circuit 11 4 WARNING Burn Hazard This heater is hot when in use To avoid burns do not let bare skin touch hot surfaces Use extreme caution when any heater is used by or near children or invalids 12 4 WARNING Risk of Electrical Shock DO NOT install the heater directly above bathtub or sink DO NOT install in shower stall area Manufacturer recommends a minimum 2 foot clearance 13 4 WARNING Risk of Electrical Shock Connect grounding lead to grounding screw provided Ke
17. en la graduaci n deseada 10 Vuelva a conectar la alimentaci n en el tablero del panel el ctrico Acerca del control de l mite de temperatura de reglaje manual El calentador est protegido por un control limitador de temperatura con reglaje manual el cual est dise ado para abrir el circuito del calentador cuando se detectan temperaturas de funcionamiento excesivas El problema debe evaluarse y el l mite debe restablecerse para que el calentador vuelva a funcionar C mo restablecer el control limitador de temperatura de reglaje manual Si el control limitador de reglaje manual ha abierto el circuito del calentador debido a temperaturas de funcionamiento excesivas el calentador no funcionar sino hasta que se oprima el bot n de l mite de reglaje manual Despu s de dejar que la unidad se enfr e durante unos 10 minutos y resolver el problema que causa que se disyunte el interruptor de l mite utilice un objeto puntiagudo como un bol grafo para acceder al bot n de reglaje manual a trav s de la secci n central inferior derecha de la rejilla del calentador Oprima el bot n FIRMEMENTE y aseg rese de escuchar y sentir un chasquido indicando que se ha restablecido INSTRUCCIONES IMPORTANTES P AN ADVERTENCIA Desconecte la electricidad en el tablero del panel el ctrico caja de cortacircuitos o fusibles y trabe o coloque un cartel en la puerta del tablero del panel para evitar que alguien vuelva a conectar la energ a mientras
18. ep all foreign objects out of heater 14 4 WARNING Risk of Electrical Shock Never place a switch where it can be reached from the tub or shower enclosure 15 4 WARNING Risk of Fire Do not block heater Heater must be kept clear of all obstructions a minimum of 3 feet in front 6 inches above and on both sides Heater must be kept clean of lint dirt and debris See Maintenance Instructions SAVE THESE INSTRUCTIONS www cadetco com Tel 360 693 2505 P O Box 1675 Vancouver WA 98668 1675 READ ALL INSTRUCTIONS AND SAFETY INFORMATION IMPORTANT It is extremely important you verify the electrical supply wires are the same voltage as the heater i e 120 volt heater to 120 volt power supply and 240 volt heater to 240 volt power supply If replacing an existing heater check the labels of the old heater and replace using the same voltage Hooking a 240 volt heater to a 120 volt power supply will drastically reduce the heater s output Hooking a 120 volt heater to a 240 volt power supply will destroy the heater Connecting your heater to an incompatible power supply will void the warranty Warranty is void if any material is sprayed on the element or blower Installation Instructions Part One PLACEMENT Install The Com Pak Bathroom Heater Model CB vertically Heater is not approved for horizontal or ceiling mount applications CONTROLS A built in thermostat and 60 minute ti
19. ical shock burns or possible death Troubleshooting Chart CONSULT LOCAL ELECTRICAL CODES TO DETERMINE WHAT WORK MUST BE PERFORMED BY QUALIFIED ELECTRICAL SERVICE PERSONNEL Problem 1 Incorrect supply voltage 2 Overloaded circuit Breaker trips immediately upon energizing heater 3 A short circuit exists in the supply or heater wiring 4 Defective circuit breaker 1 Insufficient element temperature 2 Incorrect supply voltage 3 Element has failed Heater fan operates but does not discharge warm air 1 Heat loss from room is greater than heater capacity 2 Thermostat is not functioning properly Heater will not shut off Solution 1 Verify that supply voltage matches the heater rating 2 The total amperage of all heaters on a branch circuit must not be more than 3 80 of the amperage rating of the circuit breaker and supply wire ratings Use a lower wattage heater or reduce the number of heaters on the circuit Shorted supply or heater wires may be accompanied by severe sparking Inspect all supply and heater wiring insulation for damage Do not reset the circuit breaker until all electrical shorts have been repaired 4 Replace the circuit breaker 1 Z 3 Allow a few moments for element to reach operating temperature Verify that supply voltage matches the heater rating Replace element Close doors and windows Provide additional insulation or install a higher wattage heater o
20. ir or replacement processed Warranty claims made after the warranty period has expired will be denied Products returned without authorization will be refused Parts and Service Visit http support cadetco com for information on where to obtain parts and service Reduce Reuse Recycle This product is made primarily of recyclable materials You can reduce your carbon footprint by recycling this product at the end of its useful life Contact your local recycling support center for further recycling instructions 2009 Cadet Manufacturing Co Printed in U S A Rev 7 11 720050 95 SAFETY amp QUALITY The Com Pak Bath Heater GUIA DEL PROPIETARIO PARA MODELOS DE MULTIVOLTAJE Ancho de 10 7 m Protecci n t rmica e Reglaje manual de alta temperatura apaga el calentador si se sobrepasan las temperaturas de operaci n normales E Elemento de acero de calidad comercial con pintura resistente al xido m Controles incorporados Termostato de polo nico con posici n de inhabilitaci n sin calor El temporizador de 60 minutos supedita el termostato para brindar calor instant neo m Proceso de pintado con cobertura pulverizada que elimina los bordes filosos cortantes E Garant a extendida de tres a os para el elemento y el motor E Probado en f brica Altura de 125 8
21. l producto Casos en que el producto resulte da ado durante el embarque por causas ajenas a Cadet LA GARANTIA DE CADET SE LIMITA A LA REPARACI N O REEMPLAZO TAL COMO SE ESTABLECE EN ESTE DOCUMENTO CADET NO SE HAR RESPONSABLE POR DA OS A LA PROPIEDAD O DA OS CONSECUENTES COMO TAMPOCO POR GASTOS ACCIDENTALES DEBIDO AL INCUMPLIMIENTO a aay GARANTIAS ESCRITAS 0 DE CUALQUIER GARANTIA EXPRESA IMPLICITA EN CASO DE QUE CADET DECIDA REEMPLAZAR ALGUNA PIEZA DEL PRODUCTO CADET LOS REPUESTOS SE REGIRAN POR LAS MISMAS GARANTIAS DEL PRODUCTO LA INSTALACION DE LOS REPUESTOS NO N o oA O MODIFICA NI PROLONGA LAS GARANT AS VIGENTES EL REEMPLAZO 0 REPARACI N DE TODO PRODUCTO O PIEZA CADET NO ORIGINA NING N TIPO DE NUEVA GARANT A 8 Estas garant as le otorgan derechos legales espec ficos y es posible que usted tenga otros derechos que var en de un estado a otro Cadet no asume ni autoriza a nadie que lo haga en su nombre ninguna otra obligaci n o responsabilidad en relaci n con sus productos que no sean las que se establecen en este documento Si durante el per odo de garant a usted considera que su producto Cadet presenta defectos comun quese con Cadet Manufacturing Co llamando al 360 693 2505 para obtener instrucciones sobre c mo tramitar la reparaci n o el reemplazo del producto Los reclamos de garant a presentados despu s de la finalizaci n del per odo no ser n acogidos Los productos que se devue
22. ll adjacent wall surfaces and 12 inches from the floor See Figure 4 mal x j Lu Q X Q lt x Figure 4 Model CB KEZ Connect Supply Wires Route supply wire from circuit breaker directly to heater Remove a knockout and attach the supply wire with a strain relief connector leaving 10 inch wire lead for later use See Figure 3 Connect supply ground wire to grounding screw supplied in wall can Mount The Wall Can Insert wall can into opening keeping wall can flush with wall surface Secure can to wall stud with 2 screws through holes provided in can Proceed to PART TWO Proceed to Part Two Installation Instructions Part Two Multi Volt Element Wiring Configuration Refer to Figures 5 6 7 and 8 for desired voltage Determine Supply Voltage Heater must be connected to a GFCI protected branch circuit Before installing the heater it is extremely important you verify the heater is configured for the correct supply voltage The Com Pak Bathroom Heater is configured for 240 Volt operation by default For 120 Volt installation you must reconfigure the heater wiring Installing the heater without configuring for the correct voltage will destroy the heater and void your warranty How to determine the supply voltage If replacing an existing heater check the labels of the old heater and replace using same voltage For new construction heater wires must be configured to the same voltage as the sup
23. lvan sin autorizaci n ser n rechazados Repuestos y servicio l l En http support cadetco com encontrar informaci n sobre d nde obtener repuestos y Servicio Reduzca reutilice recicle Este producto est hecho principalmente de materiales reciclables Puede reducir la cantidad de carbono que contribuye al medio ambiente reciclando este producto al t rmino de su vida til Comun quese con su centro local de reciclaje para obtener mayores instrucciones al respecto 2009 Cadet Manufacturing Co IMPRESO EN EE UU Rev 7 11 720050 BLANK
24. mer Note Do not use with a wall thermostat How do I install for new construction Mount The Wall Can The CB Series heater REQUIRES A MINIMUM distance of 6 inches from adjacent surfaces and 4 inches from the floor However Cadet RECOMMENDS 12 inches from all adjacent surfaces and 12 inches above the floor for longer and cleaner performance Heaters must be spaced at least 3 feet apart Secure the wall can to the stud with 2 screws See Figures 1 amp 2 As an option the rubber shim provided may be attached to side of wall can to square the wall can to the stud ih Figure 1 Face of wall can must extend Y or 5 s inch from face of stud to allow for thickness of sheetrock Figure 2 Attach wall can to stud with screws through holes provided in wall can Connect Supply Wires Route the supply wire from circuit breaker to heater Remove a knockout and attach the supply wire with a strain relief connector leaving 10 inch wire lead for later use Connect supply ground wire to grounding screw in wall can See Figure 3 Proceed to PART TWO KNOCK OUT TWIST TO REMOVE STRAIN RELIEF CONNECTOR SCREW Figure 3 How do install in an existing wall Cut Hole In Wall Cut a hole 8 inches wide by 10 inches high next to a wall stud This heater REQUIRES A MINIMUM distance of 6 inches from adjacent wall surfaces and 4 inches from the floor However Cadet RECOMMENDS 12 inches from a
25. peratura preestablecida 3 Para reducir la temperatura del ambiente gire la perilla en sentido contrario a las manecillas del reloj G rela en sentido de las manecillas del reloj para aumentarla 4 Sidesea un calor superior al indicado por el termostato gire el temporizador a los minutos que desee El temporizador est a la izquierda y se representa por el s mbolo Los n meros indican minutos El calentador permanecer encendido hasta que acabe el per odo el control del calentador volver al termostato y al punto de ajuste anterior Mantenimiento Seg n sea necesario o cada seis meses como m nimo 1 A ADVERTENCIA Antes de quitar la rejilla desconecte la electricidad en el tablero del panel el ctrico cortacircuito o caja de fusibles Trabe o coloque un cartel en la puerta del tablero del panel para evitar que alguien conecte accidentalmente la energ a mientras se est trabajando en el calentador De lo contrario podr an producirse graves golpes el ctricos quemaduras e incluso la muerte 2 Antes de proceder es importante que usted verifique que se haya desconectado la alimentaci n y que el calentador no reciba energ a Los cortacircuitos no suelen estar correctamente marcados y apagar el incorrecto podr a significar que sigue fluyendo electricidad Nota Si la perilla del termostato se gira completamente en el sentido contrario a las manecillas del reloj quedar en la posici n de inhabilitaci n
26. ply wires If you need assistance consult a qualified electrician JA Select Proper Heater Voltage For 240 Volt configuration The Com Pak Bathroom Heater is configured for 240 Volt operation by default 240 VOLT POWER SUPPLY Figure 5 SPARE TERMINAL ON ELEMENT TIMER THERMOSTAT A est 3 6 JUMPER WITH INSULATED 0 D MANUAL RESET HIGH y TEMPERATURE LIMIT White Wire Black Wire Y li Blue Wire For 120 Volt Configuration To configure heater for 120 Volt disconnect the blue wire from terminal D and connect it to terminal A Then connect the loose red wire to terminal D 120 VOLT POWER SUPPLY Figure 6 JUMPER WITH 7 TIMER THERMOSTAT INSULATED 0 D D MANUAL RESET HIGH TEMPERATURE LIMIT Blue Wire White Wire N WARNING Turn the electrical power off at the electrical panel board circuit breaker or fuse box and lock or tag the panel board door to prevent someone from turning on power while you are working on the heater Failure to do so could result in serious electrical shock burns or possible death N WARNING Risk of Electrical Shock Connect grounding lead to grounding screw provided Keep all foreign objects out of heater N WARNING Risk of Fire Heater must be kept clear of all obstructions a minimum of 3 in front 6 on both sides and above Heater must be kept clean of lint dirt and debris A Installation Instructions How
27. por delante 6 pulgadas por encima y en cada costado Los calentadores deben mantenerse sin pelusas suciedad ni Podr an producirse explosiones o incendios NO instale l ae residuos Consulte las instrucciones de mantenimiento el calentador en areas donde exista la presencia de vapores gases o l quidos combustibles o exceso de pelusas o polvo CONSERVE ESTAS INSTRUCCIONES www cadetco com Tel 360 693 2505 P O Box 1675 Vancouver WA 98668 1675 LEA TODAS LAS INSTRUCCIONES E INFORMACION ACERCA DE LA SEGURIDAD IMPORTANTE Es extremadamente importanteverificar que los cables de suministro el ctrico sean del mismo voltaje que el calentador es decir un calentador de 120 voltios con un suministro de energ a de 120 voltios y un calentador de 240 voltios con un suministro de energ a de 240 voltios Si va a reemplazar un calentador existente revise las etiquetas del calentador antiguo y sustit yalo por otro del mismo voltaje Si se conecta un calentador de 240 voltios a un suministro de energ a de 120 voltios se reducir dr sticamente el rendimiento del calentador Si se conecta un calentador de 120 voltios a un suministro de energ a de 240 voltios se destruir el calentador Si se conecta el calentador a un suministro de energ a incompatible se anular la garant a La garant a pierde su validez si se roc a alg n producto en el elemento o en el soplador Instr
28. r or vacuum on blow cycle to blow debris through the top element do not touch element 7 Vacuum fan area without touching the elements 8 Replace grill and secure with screws 9 Turn thermostat to desired setting 10 Turn power back on atthe electrical panel board About the Manual Reset Temperature Limit Control The heater is protected by a temperature limiting control The manual reset temperature limit control is designed to open the heater circuit when excessive operating temperatures are detected The problem must be assessed and the limit must be reset to resume operation Resetting the Manual Reset Temperature Limit Control If the manual reset limit control has opened the heater circuit due to excessive operating temperatures the heater will not work until the manual reset limit button is pressed After allowing the unit to cool for at least 10 minutes and resolving the problem causing the limit to trip use a narrow object such as a ball point pen to access the manual reset button through the lower right center section of the heater grill Press FIRMLY and be sure to listen and feel for a click indicating it has been reset WARNING IMPORTANT INSTRUCTIONS Al Seas Turn the electrical power off at the electrical panel board circuit breaker or fuse box and lock or tag the panel board door to prevent someone from turning on power while you are working on the heater Failure to do so could result in serious electr
29. r multiple heaters if necessary If your circ uit is rated for more capacity 2 Wait for the timer to time out or turn the timer counterclockwise to 0 The timer overrides the thermostat setting If heater continues to run adjust thermostat to its lowest setting If heater continues to run allow two minutes for thermostat to respond the thermostat requires replacement Heater discharges smoke 1 Dust lint or other matter has 1 Clean heater See Operation amp Maintenance section for instructions or emits a burnt odor accumulated inside heater Element heats for a moment without the fan turning then 2 Fan or motor jammed immediately stops heating 1 Thermostat is set too low or in disabled no heat position 2 Heater has tripped the manual high temperature reset switch 3 Power not on at the circuit breaker 4 Broken or poorly connected wire s to heater 5 Defective thermostat and or timer Heater does not run 1 Dust lint or other matter has accumulated inside heater 2 Airflow is blocked Heater continually trips the manual reset temperature limit control 3 Fan or motor is jammed 4 None of the above 1 Defective motor or internal connection le Heater or fan motor requires replacement 2 Remove obstruction and press heater reset button after allowing the unit to cool 3 Test heater operation if reset button has been pressed be sure to listen and feel for a click indic
30. six months minimum 1 N WARNING Before removing grill turn the electrical power off at the electrical panel board circuit breaker or fuse box Lock or tag the panel board door to prevent someone from accidentally turning the power on while you are working on the heater Failure to do so could result in serious electrical shock burns or possible death It is important that you verify power has been turned off and no power is going to the heater before proceeding Circuit breakers are often not marked correctly and turning the wrong breaker off could mean electricity is flowing to the heater even if the heater does not appear to be working If you are uncomfortable working with electrical appliances unable to follow these guidelines or do not have the necessary equipment consult a qualified electrician N Note If thermostat knob is turned fully counterclockwise it will be in the disabled no heat position JA Install Grill Secure grill with the screws provided Slide thermostat knob onto right control shaft extending through the grill and the timer knob onto the left shaft Turn power on at the electrical panel board Figure 10 Ig Uy Y APRA A 3 Once you verify the power has been turned off correctly proceed to the next step 4 Remove screws and take off grill 5 Wash grill with hot soapy water and dry immediately 6 While holding fan to avoid damage or bending use a hair drye
31. ucciones para la instalaci n Parte Uno UBICACI N Instale verticalmente el calentador de ba o Com Pak Modelo CBC No se ha aprobado el uso horizontal del calentador ni tampoco su montaje en cielo raso CONTROLES Un termostato incorporado y temporizador de 60 minutos Nota No lo use con un termostato mural C mo se instala el calentador en una construcci n nueva IET Montaje de la c mara de pared Este calentador serie CB requiere una distancia M NIMA de 6 pulgadas desde las superficies adyacentes y 4 2 pulgadas desde el piso Sin embargo Cadet recomienda 12 pulgadas de distancia desde todas las superficies adyacentes y 12 pulgadas por sobre el piso para una vida til m s larga y un funcionamiento m s limpio Si se instalan varios calentadores deje al menos tres pies entre ellos Fije la c mara de pared al puntal con 2 tornillos consulte las figuras 1 y 2 Como alternativa se puede a adir la cu a de caucho suministrada al costado de la c mara de pared para cuadrarla con el puntal Figura 1 La superficie de la c mara de pared debe sobresalir entre 1 2 pulgada y 5 8 de pulgada de la superficie del puntal a fin de dejar espacio para la l mina de yeso Figura 2 Conecte la c mara de pared al puntal mediante los tornillos por los orificios que contiene la c mara EY Conecte los alambres de suministro Tienda el cable de suministro desde el cortacircuito al calentador Quite

Download Pdf Manuals