Burnham Series C Power Flame Data Sheet
Contents
1. Boiler Size Gas 2 Oil 1 Explanation of Firing Sequences AMERICAS BOILER COMPANY Burner Model Gas and C1i 10 C1i 12 C2 15 C2 20B C2 20B C3 20 C3 20 C3 25B C4 30 C5 30 C5 30 C6 30 2 Oil C1 O C1 O C2 OA GZS 20A C2 OA C2 OB C2 OB C3 O C3 O C3 OB C4 OB C5 O C5 O C6 O Motor Horsepower Gas 2 Oil and Gas 2 Oil Power Flame Burner Information Voltage 115 60 1 115 60 1 230 60 1 230 60 1 230 60 1 230 60 1 2 2 3 z Sn 7 1 2 7i 10 i Gas and Gas Sequence on Combination Gas Oil Boilers On Off L H O Oil and Oil Sequence on Combination Gas Oil Boilers On Off Fixed air damper oil valve On Off LFS Fixed air low fire start L H O 2 Oil blower motor is 3 4 hp and combination gas oil is 1 hp 3 Voltage on gas burner model is 115 60 1 308 460 3 208 460 3 208 460 3 208 460 3 208 460 3 208 460 3 Slow opening gas valve fixed air damper diaphragm gas valve Firing Sequence Gas 1 2 Oil and Gas 2 Oil Standard UL Flame Safeguard Gas RM7897A UV RM7897A UV RM7897A UV RM7897A UV RM7897A UV RM7897C UV RM7897C UV RM7897C UV RM7897C UV RM7897C UV RM7840L UV RM7840L UV RM7840L UV Slow opening gas valve adjustable position LFS air damper linked to motorized gas valve 2 0il R7184P CC R7184P CC R7184P CC R7184P CC
2. R7184P CC R7184P CC RM7897C UV RM7897C UV RM7897C UV RM7897C UV RM7840L UV RM7840L UV RM7840L UV Adjustable air damper spring close linked to oil pressure cylinder oil pressure regulator and by pass valve for LFS Gas 2 Oil RM7897C UV RM7897C UV RM7897C UV RM7897C UV RM7897C UV RM7897C UV RM7897C UV RM7897C UV RM7897C UV RM7897C UV RM7840L UV RM7840L UV RM7840L UV a L451 ap Size I Min Pres 1 11 4 11 4 11 21 11 4 2 11 2 2 11 2 2 11 2 Gas Train Max Pres 3 5 w c 5 5 w c 4 5 w c 6 8 w c 5 2 Wwe 6 7 w c 8 0 w c 7 9 w c 7 4 w c 10 5 w c 10 0 w c 10 9 w c 11 5 w c 14 0 w c 14 0 w c 14 0 w c 14 0 w c 14 0 w c 14 0 w c 14 0 w c 14 0 w c 14 0 w c 14 0 w c 28 0 w c 28 0 w c 28 0 w c 4 Model C 50 amp C 60 Dual size gas trains Leak test cock and main gas valve are indicated by the first number combination gas valve regulator and main shutoff cock are indicated by the second number 5 Models C 70 amp C 80 Dual size gas trains Leak test cock main gas valve and auxiliary gas valve are indicated by the first number gas regulator and main shutoff cock are indicated by the second number AMERICA S BOILER COMPANY Power Flame Burner Equipment _ Equipment Fuel S O Control Cabinet Gas 2 Oil Gas 2 Oil NEMA 1A with hinged door Control Voltage Transform
3. er Gas 2 Oil Gas 2 Oil Included with all but 115 60 1 burners Motor Starter Gas 2 Oil Gas 2 Oil Contactor on all single phase motors Magnetic starter with overload protection on 3 phase motors Ignition Gas and Gas 2 Oil Gas Electric pilot _ 2 Oil Direct spark Gas 2 Oil Gas 2 Oil All models Air Flow Safety Switch urgi 70 and larger Gas Train Gas and Gas 2 Oil UL gas train for minimum inlet pressure indicated on Burner Information table Shipped unassembled and consisting of the following e Manual shut off valve e Gas pressure regulator e Manual leak test valve e Automatic gas valve Diaphragm type with On Off sequence Solenoid type all others Safety gas valve Solenoid type High and Low gas pressure switches Models C 60 and larger Oil Pump 2 Oil and Gas 2 Oil Oil and Gas 2 Oil Integral with burner with burner Pilot Gas Controls Gas Kabalin Oil Gas 2 Oil All models with maei aan viens eee meee emer pilot have manual pilot shut off valve soft seat low gas pressure regulator and solenoid gas valve Fuel Changeover Gas 2 Oil Manual switch
Download Pdf Manuals
Related Search
Related Contents
VL100 voyager VL100 voyager DC-MAX REV DC-MAX REV 4 取扱説明書 the Manual guide plantes sauvages SILICON CARBIDE POWDER (M1203057 - 2006-06-29 Pour une performance durable des zones d`activités User Manual Transcend 256MB, Jetram, DDR, DIMM,400MHz, CL2 Käyttöohje Operating Instructions Samsung 23" TV-skärm med kristallklart stativ Bruksanvisning Copyright © All rights reserved.