Bryant Thermostat TZEMT400AB32MAA User's Manual
Contents
1. Uses gas for heating Has a W or W1 wire but does NOT have a W2 OGas Furnace Multistage Uses gas for heating Has a W or W1 wire plus a W2 for 2nd stage heat and or Y2 for 2nd stage cool O Electric Furnace Single Stage Uses electric for heating Does NOT have an O or B terminal those are unique to a Heat Pump system Has a W or W1 wire but does NOT have a W2 O Electric Furnace Multistage Uses electric for heating Does NOT have an O or B terminal those are unique to a Heat Pump system Has a W or W1 wire plus a W2 for 2nd stage heat and or Y2 for 2nd stage cool CHeat Pump Single Stage Has an O or B terminal for the change over valve which is unique to heat pumps Does NOT have a Y2 terminal for 2nd stage heat and cool CHeat Pump Multistage Has an O or B terminal for the change over valve which is unique to heat pumps Has a Y2 terminal for 2nd stage heat and cool or high utility costs Follow the System Type table carefully to properly select and setup the control to ensure proper CAUTION EQUIPMENT DAMAGE HAZARD Improper system type selection can lead to equipment damage A heating and cooling system operation Remove existing wall plate MERCURY NOTICE Note During this process make sure that the wires do When th
2. Done Select button oD Scroll up E scron down Select button Perform System Checkout 20 Test Fan Operation oQa2900p b c d e Press the FAN button a e Scroll to ON Sys Off 76H Verify that the system fan starts and moves air Run 15 74C Press the FAN button AUTO AUTO Scroll to AUTO MENU MODE FAN Press the Done button to return to the home screen O Q P Test Cooling Operation if your system has cooling a Press the MODE button MODE FAN Scroll to COOLING button button Press the Done button to return to the home screen Turn the temperature down using the scroll down button until the new setpoint is below the room temperature Verify that the outdoor unit and the system fan come on and run oD A CAUTION Do not run the air conditioner if the outdoor temperature is below 55 degrees F e Test Heating Operation if your system has heating a b C d Press the MODE button Scroll to HEATING Press the Done button to return to the home screen Turn the temperature up using the scroll up button until the new setpoint is above the room temperature Verify that the heating system turns on and runs This concludes the system checkout If any part of your system fails to come on when performing this checkout procedure verify that the correct wires were connected to the wall plate and that each wire is securely attached to the appropriate te
3. Multistage Mechanical Settings 20 sao Press the MENU button twice Press and hold the two inner buttons for 3 seconds to view Installer Settings Scroll down to System Settings and press the Select button Scroll to Mechanical Settings it is the first option then press the Select button Scroll down to 2nd Stage Heat Press the button to change the setting to Y for Yes Press the Done button 4 times to return to the Home screen If your system also has 2nd stage air conditioning go to step 3D e f g h i J If Multistage System continue with steps g through 19B Electric Furnace Mechanical Settings Press the MENU button twice Press and hold the two inner buttons for 3 seconds to view Installer Settings Scroll down to System Settings and press the Select button Scroll to Mechanical Settings it is the first option then press the Select button Scroll down to Fan Type Press the button to change the setting Electric If Single Stage System setup is complete press Done PR GR J Scroll down to 2nd Stage Heat Press the button to change the setting to Y for Yes Press the Done button to return to the Home screen If your system also has 2nd stage air conditioning go to step 3D a b 20 sQ o If Mutistage System continue with steps a3 TaY 19C Heat Pump Mechanical Settings Press the MENU button twice Press and hold the two inner buttons for 3
4. That wire is required to power the new thermostat It is typically but not always colored blue With battery powered thermostats it most likely will not be connected to the HVAC unit It is typically identified with one of the following terminal names C X B COM If your existing thermostat is battery powered and did not use the 24 Volt common wire contact a qualified heating and cooling service contractor as needed to properly attach the wire 4 Locate the wiring labels located in the box with the new thermostat lt a Look at where each wire is connected to the existing thermostat and find the letter shown next to that wire terminal b Peel off the matching label and wrap it around each corresponding wire c If you have a terminal with a letter that is not shown on the label wrap a piece of masking tape around that wire and write down that terminal name on the tape Wire colors are not necessarily an indicator of which labels should be used Y G B C E F G Oj L YI v2 gt 9 F 4d OO TI WIA Re Rh X2 T wi W2 w3 xX Y R R a i uju OW UN 2X L kM eM eM X A 5 Label the wires on your existing thermostat to match terminal names a N Wire colors and letters may ran 6 Identify your System Type from the list below You will need to check your wire labels to help identify the system type OGas Furnace Single Stage
5. will blink while enrollment is taking place Enrollment is complete when the orange light becomes solid 11 15AM Outside 60 Menu Selection 76 H User Settings Usage Graph a 9205 15 74C ESM Setpoints v gt ZWave Install U MENU MODE FAN RUN Done Select Scroll down soe e 2 e e MENU button Select button 23 Verify enrollment of the thermostat a Press the MENU button on the thermostat Thermostat Info b Scroll down to Thermostat Info and press the Select button TZEMT400AB32 Ver 01 00 10 c Look at the number listed after ZNID ZVER 02 00 0 ZNID 01 If the number listed there is anything other than 000 the thermostat ae Se age cee stem Type andar has been successfully enrolled Fan Type CEG If the number listed there is 000 the thermostat has NOT been Done successfully enrolled In this case repeat step 22 and verify again o o Press Done button when finished ZNID 10 24 Establish Online Control of the Thermostat Schlage LINK account must be active before continuing See link schlage com for more information a Plug the Ethernet and power cord back into the bridge b Log into your account at www schlagelink com c Click the Climate tab and follow the onscreen instructions 11
6. x New Thermostat Terminals 24COM 24RC 24RH wi w2 0 G Y1 Y2 Not used System Type Heat Pump Change Over Multistage Compressor Single Stage amp Multistage ca B 2 Themostat Brand Wire Labels Hell Quaker Pe r wi fo e m w Honeywell Robert Shaw White Rogers c Rc R caw ow G Yorvi Y2 L Payne e r eawe o vorvi v w Rheem Ruud S E E Trane American Standard Weathertron Fe Rl Ta mE New Thermostat Terminals 24COM 24RC 24RH wi w2 0 G Y1 Y2 Not used If you have any of the following pairs of terminals E amp W1 E amp W2 E amp Y X2 amp W connect both wires to W1 E Attach all wires securely to the new thermostat A N Note A wire must be connected to 24COM to power the thermostat a Use the information from step 12 to match the wires to the correct terminals b Use 1 8 blade screwdriver to secure wires in terminals Follow the Terminal Connection information from step 12 carefully to ensure the control is wired properly After wires are secure bare wires MUST NOT touch each other CAUTION EQUIPMENT DAMAGE HAZARD Improper wiring can lead to equipment damage 14 If necessary cut the internal jumper wire JP1 Skip this step if there is a single wire connected to either 24RC or 24RH However if there is a wire connected to BOTH 24RC and 24RH see the information below about cutting t
7. If mounting to drywall with no studs behind it enlarge pilot holes to 1 8 for anchors b If using anchors screw them into the holes 41 Install new wall plate a Pull wires through hole in center of wall plate b Locate the new wall plate over existing opening c Attach wall plate to wall using two screws provided Do not overtighten 12 Review the wiring chart information a Find the chart below that has your correct System Type On the chart find the Thermostat Brand that matches your existing thermostat b c Compare your Wire Labels to the chart and identify which ones you have it may only have some of the ones shown d Look at the New Thermostat Terminals row at the bottom of the chart to see what your wires connect to System Type Gas or Electric Multistage Heating Multistage Cooling Single Stage amp Multistage Stage 2 Stage 2 Themostat Brand Wire Labels Hell Quaker Pc r worws we o vor ve w Honeywell Robert Shaw White Rogers ee ie a ea ee ea lena a i Lennox CB19 E ee Kea ae Lennox HP19 20 a a a ar Lennox HP21 CB21 E ee ea ee eee ee Lennox HP22 CB19 a a a ea ee ee Payne c r worwt wa vorvi ve ms Rheem Ruud a a S aoe Trane American Standard Weathertron B R wWorwi we G yYorvt Y2 Whe York Bo R worwt wa a vorvi v2
8. SCHLAGE l LiNK Thermostat Guide S TRANE Model TZEMT400AB32MAA Tools Needed NOTE This thermostat is not compatible with dual fuel systems heating system with both heat pump and gas furnace unless the system is controlled with a dual fuel accessory relay kit If you are unsure whether your dual fuel system is controlled with this accessory or if you need a dual fuel kit please contact a qualified heating and cooling contractor ore Ok Ej 2 Table of Contents Physical Installation and Wiring Pages 2 6 System Settings at Thermostat Pages 7 8 Perform System Checkout Enroll Thermostat into Schlage LINK System Pages 10 11 am Ingersoll Rand Security Technologies 2009 Schlage Lock Company Customer Service Phone 877 288 7707 Thermostat Guide Rev 5 09 Alpha Physical Installation and Wiring WARNING Voltage hazard Can cause electrical shock or equipment damage Turn off all power to heating and cooling equipment before beginning installation 2 Remove the existing thermostat cover from the wall plate Leave wires attached Consult instructions that came with existing thermostat as needed The look of your existing thermostat may vary Thermostat cover Wall plate 4 EJ If your existing thermostat is battery powered Look to see if there is a 24 Volt Common wire attached to your existing thermostat
9. button b Scroll up or down to User Settings it is the first d option then press the Select button g Menu Selection Scroll User Settings Usage Graph a up ESM Setpoints WwW ZWave Install y Done JF Select Scroll down Select button 9 Scroll up or down to Set Clock it is the first option then press the Select button User Settings Set Clock Filter Service Maint Service Screen Timeout Done esee Select button E Scrol a up Select U scrol down Press 4 or gt to highlight the data you want to change Scroll up or down or to make changes Press the Set button when you are finished Press the Done button twice to exit the menu Set Clock Time 15AM Date 3 23 09 Day Mon Back 4 gt Q O Set button A om up Set A FE seron down 18 If your System Type is O Gas Furnace Single Stage go to step 20 O Gas Furnace Multistage perform step 19A O Electric Furnace perform step 19B O Heat Pump perform step 19C If your Gas or Electric furnace system also has O Electric Air Conditioning Multistage perform additional step 19D Note It may be necessary to go back and review step 6 in the installation section to verify the differences between the system types 19A Gas Furnace
10. he JP1 jumper If terminals 24RC and 24RH both have wires connected to them the JP1 jumper wire must be cut The jumper is located on back of the thermostat face as shown in the illustration to the right IMPORTANT Before cutting the JP1 jumper recheck the labels on your wiring against the chart on page 12 to verify that both terminals 24RC and 24RH were used on the old thermostat and should have wires connected to them on the new thermostat QUT AUNPERTIOG SPLUILBCIRA CUT AONPERTSO SPL BCIRA 15 Attach the thermostat face to the wall plate a Tuck wiring flat inside the wall plate b Carefully place the face plate against wall plate while aligning pins into wire terminals c Push thermostat face into wall plate until it is secure If thermostat face does not easily slide into wall plate DO NOT force it Check alignment of pins on back of thermostat face Also make sure wiring is pressed flat and is not bunched together pressed flat wf 16 Turn power to heating and cooling system back on The thermostat display should turn on and begin displaying information If the thermostat display does not come on go back through the installation steps and look for problems Pay special attention to steps 3 and 12 System Settings at Thermostat Set Time and Date a Press the MENU button twice 11 15AM Outside 60 75 73H a 74C MENU MODE FAN RUN e o o MENU
11. is control is replacing an old control that not pull back into wall opening contains mercury in a sealed tube do not dispose of your old control in the trash Dispose of properly Contact your local waste management authority for instructions regarding recycling and proper disposal of the old control a Detach all wires from wall plate b Remove all screws attaching the wall plate to the wall and remove wall plate at aa ee y A listing of heating ventilating and air conditioning c See MERCURY NOTICE to the right wholesalers that participate in the Thermostat Recycling Corporation s recycling program are available at www thermostat recyle org 8 Separate the face of the TZEMT400 thermostat from the wall plate Apply pressure at two tabs on top of wall plate to release it NOTE It is not recommended that this Z wave thermostat be mounted onto metal structures Metal may affect the radio frequency RF communication between the thermostat and the Z wave bridge f 9 Mark two mounting holes using new wall plate Pull wires through hole in center of wall plate Locate the new wall plate over existing opening Mark two holes with pencil Use a level to verify that the two holes locations are level Correct holes locations as needed e290 10 Prepare two mounting holes a Drill 1 16 pilot holes in the two locations that were marked in step 9
12. rminal Also go back and verify that you have set up the Mechanical Settings to match your System Type Note It may take approximately 5 minutes for the system to start up after switching from COOLING to HEATING mode There is a built in time delay which will not allow the equipment to turn on until it is ready The screen will display the word Wait until the time delay has finished Enroll Thermostat into Schlage LiNK System 21 Prepare the bridge for enrollment d a Unplug Ethernet and power cables from bridge b Verify that blue light is blinking If blue light is solid battery is dead c Install a quality 9 volt battery d Take bridge to the location where the thermostat is mounted 22 Enroll the thermostat into the bridge If you are using a controller that is not a Schlage LINK bridge consult the instructions that came with the controller to find out how to enroll a new device a Hold the bridge within 6 feet 1 8 meters of the thermostat throughout all of step 2 Important Note After you begin the enrollment process you have 30 seconds to complete the remainder of the steps Study the steps below before beginning Press and release the plus button on the bridge Press the MENU button on the thermostat Scroll down to Z Wave Install and press the Select button Press the Yes button to enroll the thermostat Observe the lights on the bridge The orange light
13. seconds to view Installer Settings Scroll down to System Settings and press the Select button Scroll to Mechanical Settings it is the first option then press the Select button Scroll to system Type Press the button to change the setting to Heat Pump Scroll down to Fan Type Press the button to change the setting Electric If Coleman Rheem or Rudd brand heat pump scroll to C O Type and change to With Heat If Single Stage System setup is complete press Done j through n Scroll down to 2nd Stage Heat Press the button to change the setting to Y for Yes Scroll down to 2nd Stage Cool Press the button to change the setting to Y for Yes Press the Done button to return to the Home screen 19D Electric air conditioning Multistage Mechanical Settings Press the MENU button twice Press and hold the two inner buttons for 3 seconds to view Installer Settings Scroll down to System Settings and press the Select button Scroll to Mechanical Settings it is the first option then press the Select button Scroll down to 2nd Stage Cool Press the button to change the setting to Y for Yes Press the Done button 4 times to return to the Home screen 11 15AM Outside 60 US MENU MODE FAN 76H 74C Pa oo Menu Two inner button buttons Mechanical Settings Type Heatpump Fan Type Elec y N C O Type w Cool v 2nd Stage Heat N
Download Pdf Manuals
Related Search
Related Contents
1 - Brother © Copyright 2008. Black Box Corporation. All rights reserved. Manual M-SF-LIFT Nutrición Parenteral GC8261, GC8260, GC8220, GC8210 User Guide - Peugeot Scooters SpectraLux Split Front ILS Lightbar Bedienungsanleitung - Benning SkyEye User`s Manual - Interactive Astronomy Copyright © All rights reserved.