1. BRYANT INC e 7310 WEST MORRIS STREET INDIANAPOLIS IN 46231 www bryant com CATALOG NO SS ASPAS07 02 Printed in USA 10 05 All specifications are subject to change without notice Home Standby 7kW 12kW 15kW GENERATOR Rated Maximum Continuous Power Capacity LP Rated Maximum Continuous Power Capacity NG Rated Voltage Rated Maximum Continuous Load Current Number of Rotor Poles Rated AC Frequency Power Factor Battery Requirement not included Shipping Weight Ibs Includes Transfer Switch Dimensions L x W x H ENGINE Valve Arrangement Ignition System Compression Ratio Fuel Consumption Natural Gas cu ft hr 1 2 Load Full Load Liquid Propane ft hr gal hr 1 2 Load Full Load 50 0 NG 58 3 LP 100 0 NG 100 0 LP bryant Model ASPAS1BBA007 7kW Model ASPAS1BBA012 12kW Model ASPAS1BBA015 15kW 7 000 Watts 12 000 Watts 15 000 Watts 6 000 Watts 12 000 Watts 13 000 Watts 120 240 120 240 120 240 108 3 NG 125 0 LP 25 0 NG 29 2 LP 50 0 NG 50 0 LP 54 2 NG 62 5 LP Group 26 Group 26 12 Volts and 12 Volts and 350 Cold cranking Amperes Minimum 56 1 53 58 1 58 76 2 08 88 2 40 Required fuel pressure to generator fuel inlet at all load ranges 5 to 7 inches of water column for natural gas 11 to 14 inches of water column for LP gas CONTROLS Model Switch AutoAutomatic Start on Utility failure 7 day exerciser Manual Test s
2. a revolving armature generator e Skewed stator Produces a smooth output waveform for compatibility with electronic equipment e Displaced phase excitation Maximizes motor starting capability Provides more surge capability than brushless generator designs e Automatic voltage regulation Regulates the output voltage to 2 prevents damaging voltage spikes GENERATOR e UL 2200 Listed For your safety a E Fully Automatic Transfers your vital electrical loads to the energized source of power I O g e Remote Mounting Mounts near your existing distribution panel for simple low cost installation lt on UL Listed For your safety e Manual Auto Off switch Selects the operating mode e Utility voltage sensing Constantly monitors utility voltage setpoints 60 dropout 80 pick up of standard voltage e Utility interrupt delay Prevents nuisance start ups of the engine set point approximately 15 seconds e Engine warm up Ensures engine is ready to assume the load set point approximately 10 seconds e Engine cool down Allows engine to cool prior to shutdown setpoint approximately 1 minute e Seven day exerciser Operates engine to prevent oil seal drying and damage between power outages e Timed Trickle Battery charger Maintains battery amperage to insure starting MICROPROCESSOR CONTROL e Main Line Circuit Breaker Protects generator from overload e Weather protective enclosure Ensures protection against moth
3. ATOR GROUND LOCATED ON THE REAR OF UNIT 26 5 Terminal Wire Ranges Electrically operated mechanically held contacts for fast positive connections Rated for all classes of load 100 equipment rated both inductive and resistive 2 pole 250 VAC contactors 160 millisecond transfer time Dual coil design Main contacts are silver plated or silver alloy to resist welding and sticking NEMA 1 enclosure is standard on the 100 amp switch ATS Rated Amps 100A 2 Pole UL Switch Terminal 1 x 1 0 12 I orae amon Y L 8 CIRCUITS 10 CIRCUITS OR 12 CIRCUITS WW Int 100A OR 2008 HOUSE MAIN SERVICE i Sam TOP VIEW nennu CONNECTION BOX il g ls g g ye o PEER C ie Neutral Lug Stud 1 x 3 8 16 Stud 1 x 2 0 14 Ground Lug NEUTRAL BAR quU OUEROOUSEURUOSUDEOUOUNEDODRUSEDEGL UL LISTED PANEL BOARD T jel LUULU srosmon Beatty come ok i A ee N eroun CONNECTION OF GENERATOR TO EXTERNAL CONNECTION PANEL
4. Home Standby 7kW 12kW 15kW Air Cooled Gas Engine Generator Sets Continuous Standby Power Rating INCLUDES e Automatic Transfer Switch with Built In Emergency Load Center e Pre wired External Connection Box e Flexible Fuel Line e Composite Mounting Pad e Pre wired conduits e Natural Gas or LP Gas Operation e GFCI duplex outlet amp 12Vdc outlet e UL Listed to Canadian safety standards 2 Year Limited Parts and Labor Warranty FEATURES Model ASPAS1BBA007 7kW 60Hz Model ASPAS1BBA012 12kW 60Hz Model ASPAS1BBA015 15kW 60Hz LISTED O INNOVATIVE DESIGN amp PROTOTYPE TESTING are key components of BRYANT s success in IMPROVING POWER BY DESIGN But it doesn t stop there Total commitment to component testing reliability testing environmental testing destruction and life testing plus testing to applicable CSA NEMA EGSA and other standards allows you to choose BRYANT with the confidence that these systems will provide superior performance O TEST CRITERIA v PROTOTYPE TESTED v SYSTEM TORSIONAL TESTED v NEMA MG1 22 EVALUATION v MOTOR STARTING ABILITY SOLID STATE FREQUENCY COMPENSATED VOLTAGE REGULATION This state of the art power maximizing regulation system is standard on all BRYANT models It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque matching the surge loads to the engine SINGLE SOURCE SERVICE
5. RESPONSE from BRYANT s dealer network provides parts and service know how for the entire unit from the engine to the smallest electronic component You are never on your own when you own a BRYANT system BRYANT TRANSFER SWITCHES Long life and reliability are synonymous with BRYANT systems One reason for this confidence is that the BRYANT product line includes its own transfer systems and controls for total system compatibility HOME STANDBY SPECIFICATIONS Home Standby 7kW 12kW 15kW e Durable OHVI Design Maximizes engine breathing for increased fuel efficiency Cylinder walls run cooler reducing oil consumption Because heat is the primary cause of engine wear the OHVI has a significantly longer life than competitive engines e Spiny lok cast iron cylinder walls Rigid construction and added durability provide long engine life e Electronic ignition spark advance and These features combine to assure smooth quick starting every time compression release ENGINE e Full pressure lubrication system Superior lubrication to all vital bearings means better performance less maintenance and significantly longer engine life e Low oil pressure shutdown system Superior shutdown protection prevents catastrophic engine damage due to low oil e High temperature shutdown Prevents damage due to overheating e Revolving field Allows for smaller light weight unit that operates 25 more efficiently than
6. er nature Hinged key locking roof panel for security Electrostatically applied epoxy paint for durability UNIT e Enclosed critical grade muffler Quiet critical grade muffler is mounted inside the unit to prevent injuries e Small compact attractive Makes for an easy eye appealing installation e Pre wired External Connection Box Easy Installation Virtually all hardware included plus step by step photographed Installation Guide e 1 Flexible Fuel Line e Composite Mounting Pad e Pre wired conduits INSTALLATION e UL Listed wire nuts Home Standby 7kW 12kW 15kW TRANSFER SWITCH amp EMERGENCY LOAD CENTER No of Poles Current Rating amps Voltage Rating VAC Utility Voltage Monitor fixed Dropout Return to Utility Exerciser weekly for 12 minutes UL Listed Dimensions H x W x D Total of Pre wired Circuits No 15A 120V No 20A 120V No 15A 240V No 20A 240V No 30A 240V Circuit Breaker Protected Available RMS Symmetrical Fault Current 250 Volts Standard Standard Model ASPAS1BBA007 approx 13 sec 26 5 X 12 5 x7 Model ASPAS1BBA012 approx 13 sec Standard Standard 26 5x 12 5 x7 Standard Standard Mechanical Dimensions in inches Model ASPAS1BBA015 approx 13 sec 26 5 x 12 5 x7 bryant Transfer Switch Features Current Rating No of Poles 100 UL Listed 2 GENER
7. r each 1 000 feet above sea level and also will decrease about 1 percent for each 12 C 10 F above 15 5 C 60 F
8. tart Engine Start Sequence Engine Warm up Engine Cool Down Starter Lock out 2 5 Amp Timed Trickle Battery Charger Automatic Voltage Regulator w Overvoltage Protection Automatic Low Oil Pressure Shutdown Overspeed Shutdown High Temperature Shutdown Overcrank Protection Safety Fuse Stops unit Power is removed control and charger still operate Start with starter control unit stays on If utility fails transfer to load takes place Cyclic cranking 7 sec on 7 rest 90 sec maximum duration 10 seconds 1 minute Starter cannot re engage until 5 sec after engine has stopped Standard Standard Standard Standard 72Hz Standard Standard Standard Rating definitions Standby Applicable for supplying emergency power for the duration of the utility power outage No overload capability is available for this rating All ratings in accordance with BS5514 IS03046 and DIN6271 Prime Unlimited Running Time Unit not recommended for prime power applications Applicable for supplying electric power in lieu of commercially purchased power Prime power is the maximum power available at variable load A 10 overload capacity is available for 1 hour in 12 hours All ratings in accordance with BS5514 IS03046 ISO8528 and DIN6271 Maximum wattage and current are subject to and limited by such factors as fuel Btu content ambient temperature altitude engine power and condition etc Maximum power decreases about 3 5 percent fo