Home

Bosch X1600 User's Manual

image

Contents

1. IEC 60950 1 2001 EN 55103 1 EN 55130 4 EN 55022 EN 55024 EN 61000 3 2 EN 61000 3 3 FCC 47 CFR Chapter 1 Part 15 44 x 440 x 210 mm 1 73 x 17 32 x 8 27 in including BNC module connections Approx 4 kg 8 82 Ib with full equipment Bosch Security Systems Installation and Operating Manual F 01U 082 088 V3 5 2008 05 24 en Specifications VIP X1600 XF F 01U 082 088 V3 5 2008 05 Installation and Operating Manual Bosch Security Systems Bosch Security Systems Robert Koch StraBe 100 D 85521 Ottobrunn Germany Telefon 089 6290 0 Fax 089 6290 1020 www bosch securitysystems com Bosch Security Systems 2008
2. modules can be found in the module manuals Configuration and Operation The configuration and operation of a VIP X1600 XF is carried out exclusively via the installed modules Furthermore the VIP X1600 XF base does not require any configuration The configuration and operation of the installed modules is described in the module manuals Bosch Security Systems Installation and Operating Manual F 01U 082 088 V3 5 2008 05 10 en Product Description VIP X1600 XF 3 4 3 4 1 3 4 2 3 4 3 Overview of Functions Network Video Server Housing The VIP X1600 XF base is a special housing for the installation of up to four standalone modules Encoder modules senders for the connection of up to four cameras each and decoder modules receivers for the connection of up to four monitors each are available For example a VIP X1600 XF with four encoder modules can make up to 16 independent video channels available Combinations of encoder modules and decoder modules are also possible The use of existing networks means that integration with CCTV systems or local networks can be achieved quickly and easily The modules are designed for installation in the VIP X1600 XF base Installing the units is a quick and easy operation that does not require any additional tools All modules are hot swappable and can be exchanged while the system is running Network Interfaces The integrated switch functionality of the VIP X1600 XF base al
3. The units do not contain any user serviceable parts Never open the housing of the power supply unit The power supply unit does not contain any user serviceable parts Ensure that all maintenance or repair work is carried out only by qualified personnel electrical engineers or network technology specialists Bosch Security Systems Installation and Operating Manual F 01U 082 088 V3 5 2008 05 8 en Safety Information VIP X1600 XF F 01U 082 088 V3 5 2008 05 Installation and Operating Manual Bosch Security Systems VIP X1600 XF Product Description en 9 3 3 1 Product Description Scope of Delivery VIP X1600 XF base Mounting kit for installation in 19 inch racks Self adhesive elastic bumpers Quick Installation Guide Product CD with the following content Quick Installation Guide Manual System Requirements document Further documentation on Bosch Security Systems products Configuration Manager MPEG ActiveX control Player and Archive Player DirectX control Microsoft Internet Explorer Sun JVM Adobe Acrobat Reader NOTICE Check that the delivery is complete and in perfect condition Have your unit checked by Bosch Security Systems if you detect any damage 3 2 3 3 System Requirements for Setup There are no additional requirements to be met for setting up the VIP X1600 XF base after installation is complete Requirements for setting up the installed
4. Vip X1609 XF VIP X1600 XF Network Video Server Base en Installation and Operating Manual BOSCH VIP X1600 XF Table of Contents en 3 Table of Contents 1 Preface 5 1 1 About this Manual 5 1 2 Conventions in this Manual 5 1 3 Intended Use 5 1 4 EU Directives 6 1 5 Rating Plate 6 2 Safety Information 7 2 1 Electric Shock Hazard 7 2 2 Installation and Operation 7 2 3 Maintenance and Repair 7 3 Product Description 9 3 1 Scope of Delivery 9 3 2 System Requirements for Setup 9 3 3 Configuration and Operation 9 3 4 Overview of Functions 10 3 5 Connections and Displays 11 4 Installation 13 4 1 Preparations 13 4 2 Installing Modules 13 4 3 Installing in a Switch Cabinet 14 4 4 Connections 16 4 5 Power On Power Off 17 5 Maintenance and Upgrades 19 5 1 Testing the Network Connection 19 5 2 Unit Reset 19 5 3 Repairs 19 5 4 Transfer and Disposal 19 6 Appendix 21 6 1 Troubleshooting 21 6 2 LEDs 21 7 Specifications 23 7 1 VIP X1600 XF Base 23 Bosch Security Systems Installation and Operating Manual F 01U 082 088 V3 5 2008 05 4 en Table of Contents VIP X1600 XF F 01U 082 088 V3 5 2008 05 Installation and Operating Manual Bosch Security Systems VIP X1600 XF Preface en 5 Preface 1 1 About this Manual This manual is intended for persons responsible for the installation and operation of the VIP X1600 XF International national and any regio
5. dant connections to the network NOTICE You cannot create a connection to a second network 4 4 2 1 Connect the VIP X1600 XF to the network via the ETH1 ETH2 or ETH3 socket 2 Connect the VIP X1600 XF to a redundant switch or hub on the same network via a free ETH1 ETH2 or ETH3 socket Direct iSCSI Connection You can connect the VIP X1600 XF directly to an iSCSI system via a free ETH1 ETH2 or ETH3 interface This connection is an alternative to using the Ethernet interfaces as a redundant network connection Use a UTP category 5 network cable with RJ45 plugs for a direct connection to an iSCSI system NOTICE You can obtain a list of compatible iSCSI systems from your supplier or directly from Bosch Security Systems This list is constantly being updated and extended F 01U 082 088 V3 5 2008 05 Installation and Operating Manual Bosch Security Systems VIP X1600 XF Installation en 17 4 5 4 5 1 Power On Power Off Power Supply The VIP X1600 XF does not have a power switch Power is provided once one or two separate power supply units have been installed Connect the VIP X1600 XF to a power supply unit and plug this into the mains The unit is now ready for use The VIP X1600 XF does not come supplied with a power supply unit CAUTION Use only power supply units approved by Bosch Security Systems Where necessary use suitable equipment to ensure that the power supply is free from interfere
6. ellow Data being transmitted 6 2 3 Module 1 Module 2 Module 3 Module 4 Does not light up Slot not occupied Lights up green Module is switched on Flashes green The module is being accessed Lights up red Startup in progress Flashes red Module is faulty for example following failed firmware upload 6 2 4 Power Fail Does not light up VIP X1600 XF is switched off Lights up green Startup complete VIP X1600 XF is operational Flashes red Defect in fans or redundant power supply unit Bosch Security Systems Installation and Operating Manual F 01U 082 088 V3 5 2008 05 22 en Appendix VIP X1600 XF F 01U 082 088 V3 5 2008 05 Installation and Operating Manual Bosch Security Systems VIP X1600 XF Specifications en 23 7 7 1 Specifications VIP X1600 XF Base Operating voltage Power consumption LAN interfaces SFP slot Displays Thermal value Operating conditions Approvals Dimensions H x W x D Weight 12 V DC redundant 49 2 W with full equipment 3 x Ethernet 10 100 1000 Base T automatic adjustment half full duplex RJ45 1 x 1 Gbps for mini GBIC modules 5 x LED status modules operation error 2 x LED network connection data transmission on every LAN interface 1 x LED SFP connection data transmission Max 170 BTU h Temperature O to 50 C 32 to 122 F relative humidity O to 95 non condensing elevation O to 3 000 m 1 86 miles
7. equipment at your local community waste collection recycling center Bosch Security Systems Installation and Operating Manual F 01U 082 088 V3 5 2008 05 20 en Maintenance and Upgrades VIP X1600 XF F 01U 082 088 V3 5 2008 05 Installation and Operating Manual Bosch Security Systems VIP X1600 XF Appendix en 21 6 Appendix 6 1 Troubleshooting If you are unable to resolve a malfunction please contact your supplier or system integrator or go directly to Bosch Security Systems Customer Service NOTICE In the Troubleshooting chapter of the Installation and Operating Manual for each module you will find a detailed table that is intended to help you identify the causes of malfunctions and correct them where possible 6 2 LEDs The VIP X1600 XF network video server is equipped with a number of LEDs that show the operating status and can give indications of possible malfunctions 6 2 1 RJ45 Sockets 10 100 1000 Base T Green LED lights up 10 MB network connection established Green LED flashes Data transmission via 10 MB network connection Green and orange LEDs light up 100 MB network connection established Green and orange LEDs flash Data transmission via 100 MB network connection Orange LED lights up 1 GB network connection established Orange LED flashes Data transmission via 1 GB network connection 6 2 2 SFP Does not light up No connection Lights up yellow Connection established Flashes y
8. in a switch cabinet ensure that the screw joints are free of tension and subject to as little mechanical stress as possible Ensure that the unit and the power supply units have sufficient grounding 4 3 2 Installing and Connecting the VIP X1600 XF CAUTION Only use power supply units approved by Bosch Security Systems 1 Prepare the switch cabinet in such a manner that you are easily able to insert the VIP X1600 XF directly at the installation point 2 Place the cage nuts in the corresponding drillings or spaces in the switch cabinet frame 3 Lift the VIP X1600 XF into the switch cabinet frame and insert the fastening screws together with the washers 4 Tighten the screws one after the other and then check once more that all the screws are tight 5 Connect one or two power supply units to the sockets on the rear of the housing and hand tighten the coupling nuts for the plug F 01U 082 088 V3 5 2008 05 Installation and Operating Manual Bosch Security Systems VIP X1600 XF Installation en 15 zz B al LILD LI OO II OO O Bosch Security Systems Installation and Operating Manual F 01U 082 088 V3 5 2008 05 16 en Installation VIP X1600 XF 4 4 4 4 1 Connections Network You can connect the VIP X1600 XF to a 10 100 1000 Base T network using a standard UTP category 5 cable with RJ45 plugs The Ethernet interfaces can be used to create one or more redun
9. ion en 13 4 Installation 4 1 Preparations The VIP X1600 XF base is designed for installation in a switch cabinet Mounting the unit in a 19 inch rack using the installation material supplied is a quick and easy operation It is also possible to operate this as a desktop unit The four elastic bumpers included in the scope of delivery ensure a non slip support CAUTION The unit is designed for indoor operation Select a suitable location for installation that guarantees to meet the environmental conditions The ambient temperature must be between 0 and 50 C 32 and 122 F The relative humidity must not exceed 95 non condensing The VIP X1600 XF generates heat during operation During installation please note the maximum heat value of 170 BTU h Ensure that there is adequate ventilation and enough clearance between the unit and heat sensitive objects or equipment Please ensure the following installation conditions Do not install the unit close to heaters or other heat sources Avoid locations exposed to direct sunlight Allow sufficient space for running cables Ensure that the unit has adequate ventilation Bear the total heat output in mind particularly when installing multiple units in a switch cabinet When making connections use only the cables supplied or use appropriate cables immune to electromagnetic interference Position and run all cables so that they are protected from damage and provide adequate cable
10. lows the ETH1 ETH2 ETH3 and SFP interfaces to be used alternatively redundantly or for cascading other units Redundant Power Supply The VIP X1600 XF base allows one or two power supply units to be connected thereby offering the option of a monitored redundant power supply In the event of power supply unit failure the VIP X1600 XF can be supplied by the second power supply unit without interruption F 01U 082 088 V3 5 2008 05 Installation and Operating Manual Bosch Security Systems VIP X1600 XF Product Description en 14 3 5 Connections and Displays 1 2 4 o o o o o an eo VIP X1600 XF 1 Installed module 2 Cover for vacant slot 3 ETH1 RJ45 socket for connection to the network or an iSCSI system 4 Sockets for connecting one or two power supply units 5 ETH2 RJ45 socket for connection to the network or an iSCSI system 6 ETH3 RJ45 socket for connection to the network or an iSCSI system 7 SFP slot for mini GBIC module 8 SFP LED lights up yellow when the unit is connected via SFP 9 LEDs status information for the modules and the VIP X1600 XF base NOTICE For more information about the LEDs see Section 6 2 LEDs page 21 Bosch Security Systems Installation and Operating Manual F 01U 082 088 V3 5 2008 05 12 en Product Description VIP X1600 XF F 01U 082 088 V3 5 2008 05 Installation and Operating Manual Bosch Security Systems VIP X1600 XF Installat
11. nal electrical engineering regulations must be followed at all times Relevant knowledge of network technology is required The manual describes the installation and operation of the VIP X1600 XF base 1 2 Conventions in this Manual In this manual the following symbols and notations are used to draw attention to special situations CAUTION This symbol indicates that failure to follow the safety instructions described may endanger persons and cause damage to the unit or other equipment It is associated with immediate direct hazards NOTICE This symbol refers to features and indicates tips and information for easier more convenient use of the unit 1 3 Intended Use The VIP X1600 XF network video server is intended for use with CCTV systems and serves to transfer video and control signals via data networks Ethernet LAN and Internet The optional modules for installation determine the range of functions Encoder modules senders and decoder modules receivers are available The encoder modules each contain RAM memory for short term recording of connected cameras Audio signals can also be transmitted with the audio versions of the encoder modules Various functions can be triggered automatically by incorporating external alarm sensors Other applications are not permitted In the event of questions concerning the use of the unit which are not answered in this manual please contact your sales partner or Bosch Sicherheitssysteme GmbH Rober
12. nce such as voltage surges spikes or voltage drops Do not connect the VIP X1600 XF to the power supply until all other connections have been made The unit is ready for operation after the VIP X1600 XF has been connected to the power supply and the mounted modules have been initialized The operational state of each module is indicated by an LED on the front panel of the VIP X1600 XF If a network connection has been set up correctly the corresponding LEDs on the RJ45 sockets ETH1 ETH2 or ETH3 light up Flashing LEDs signal that data packages are being transmitted over the network In the case of a redundant network connection or a direct connection to an iSCSI system these signals can also be seen on the LEDs of all RJ45 sockets in use NOTICE For more information about the LEDs see Section 6 2 LEDs page 21 Bosch Security Systems Installation and Operating Manual F 01U 082 088 V3 5 2008 05 18 en Installation VIP X1600 XF F 01U 082 088 V3 5 2008 05 Installation and Operating Manual Bosch Security Systems VIP X1600 XF Maintenance and Upgrades en 19 5 Maintenance and Upgrades 5 1 Testing the Network Connection You can use the ping command to check the connection between two IP addresses This allows you to test whether a unit in the network is active 1 Open the DOS command prompt 2 Type ping followed by the IP address of the unit If the unit is found the response appears a
13. not be ensured remove it from service and secure it to prevent unauthorized operation In such cases have the unit checked by Bosch Security Systems Safe operation is no longer possible in the following cases if there is visible damage to the unit or power cables ifthe unit no longer operates correctly if the unit has been exposed to rain or moisture if foreign bodies have penetrated the unit after long storage under adverse conditions or after exposure to extreme stress in transit 2 2 Installation and Operation The relevant electrical engineering regulations and guidelines must be complied with at all times during installation Relevant knowledge of network technology is required to install the unit Before installing or operating the VIP X1600 XF make sure you have read and understood the documentation for the modules in use and for any other equipment connected to it such as cameras or monitors The documentation contains important safety instructions and information about permitted uses Perform only the installation and operation steps described in this manual Any other actions may lead to personal injury damage to property or damage to the equipment 2 3 Maintenance and Repair Never open the housing of a VIP X1600 XF base The unit does not contain any user serviceable parts Remove only the supplied cover when installing a module Do not change any components in a VIP X1600 XF base or a module
14. s Reply from followed by the number of bytes sent and the transmission time in milliseconds If not the unit cannot be accessed over the network This might be because The VIP X1600 XF is not correctly connected to the network Check the cable connections in this case The module is not correctly integrated into the network Check the IP address subnet mask and gateway address 5 2 Unit Reset You can use the Factory Reset button to individually restore each module to its original settings It is not possible to reset the VIP X1600 XF base 5 3 Repairs CAUTION Do not change any components in the modules or the VIP X1600 XF base The unit does not contain any user serviceable parts Ensure that all maintenance or repair work is carried out only by qualified personnel electrical engineers or network technology specialists In case of doubt contact your dealer s technical service center 5 4 Transfer and Disposal The VIP X1600 XF the VIP X1600 XF base or a module should only be passed on together with this Installation and Operating Manual Your Bosch product is designed and manufactured with high quality materials and components which can be recycled and reused This symbol means that electrical and electronic equipment at their end of life should be disposed of separately from your household waste In the European Union there are separate collection systems for used electrical and electronic products Please dispose of this
15. strain relief where needed Avoid impacts blows and severe vibrations as these can irreparably damage the unit 4 2 Installing Modules Installation of the different modules in the VIP X1600 XF base is described in the relevant Quick Installation Guides and the Installation and Operating Manuals It is also possible to install remove and exchange modules during operation CAUTION Ensure that Slot 1 is always populated by a module even when modifying the installation Malfunctions may occur when the VIP X1600 XF is switched on without a functional module in Slot 1 Bosch Security Systems Installation and Operating Manual F 01U 082 088 V3 5 2008 05 14 en Installation VIP X1600 XF 4 3 Installing in a Switch Cabinet 4 3 1 Preparations The VIP X1600 XF is set up for installation in a 19 inch rack The necessary installation equipment is included in the scope of delivery CAUTION When installing in a switch cabinet ensure that there is sufficient ventilation for the unit There must be at least 5 cm 1 97 in of free space to the left and right of the unit and at least 10 cm 3 94 in at the rear The VIP X1600 XF generates heat during operation During installation please note the maximum heat value of 170 BTU h When mounting additional units direct contact with the VIP X1600 XF is permitted provided that the surface temperature of the adjacent units does not exceed 50 C 122 F When installing
16. t Koch Stra e 100 85521 Ottobrunn Germany www boschsecurity com Bosch Security Systems Installation and Operating Manual F 01U 082 088 V3 5 2008 05 6 en Preface VIP X1600 XF 1 4 EU Directives The VIP X1600 XF network video server complies with the requirements of EU Directives 89 336 Electromagnetic Compatibility and 73 23 amended by 93 68 Low Voltage Directive 1 5 Rating Plate For exact identification the model name and serial number are inscribed on the rating plate on the bottom of the VIP X1600 XF base and on the rating plates on the circuit boards of the modules Please make a note of this information before installation if necessary so as to have it to hand in case of questions or when ordering spare parts F 01U 082 088 V3 5 2008 05 Installation and Operating Manual Bosch Security Systems VIP X1600 XF Safety Information en 7 2 Safety Information 2 1 Electric Shock Hazard _ Never attempt to connect the unit to any power network other than the type for which it is intended Use only power supply units approved by Bosch Security Systems Never open the housing of the power supply unit Always install a module in the appropriate VIP X1600 XF base housing only If a fault occurs disconnect the VIP X1600 XF from the power supply and from all other units Install the power supply and the unit only in a dry weather protected location If safe operation of the unit can

Download Pdf Manuals

image

Related Search

Related Contents

WBグラウト-J  Casio Projector XJ-M140/XJ-M145 User's Manual      LEICA MP Notice d`utilisation / Gebruiksaanwijzing  ML/I User`s Manual  user manual  HP 3000-Blatt-Stapeleinheit und HP 3000-Blatt    

Copyright © All rights reserved.
Failed to retrieve file