Home
Bosch VG5 User's Manual
Contents
1. Locked Function Comm Command Description Key No On Off 1 Scan 360 Auto Pan without limits On Off 2 Auto Pan Auto Pan between limits j On Off 3 Iris Control Enters menu auto manual s On Off 4 Focus Control Enters menu spot auto manual On Off 7 Play Custom Pre position Tour Activate Deactivate On Off 8 Play Pre position Tour Activate Deactivate ii On Off 9 Inactivity Mode Enters menu Off Return to Scene 1 Recall Previous PTZ Command x On Off 11 Auto Iris Level Adjust Enters Iris Level Adjustment menu On Off 14 Set Autopan and Scan Speed Enters speed adjustment slide bar On Off 15 Set Pre position Tour Period Enters dwell adjustment slide bar dwell On Off 18 AutoPivot Enable Enables disables AutoPivot On Off 20 Backlight Comp Backlight Compensation On Off 23 Electronic Shutter Enters Shutter Speed slide bar On Off 24 Stabilization Electronic Stabilization On Off 26 Wide Dynamic Range Activate Deactivate On Off 35 White Balance Mode Enters White Balance menu On 40 Restore Camera Settings Restores all setting to their original defaults 3 On Off 41 Line Lock Phase Adjust Enters delay adjustment slide bar On Off 42 Sync Mode On Line Lock Off Internal On Off 43 Auto Gain Control AGC On Auto Off On Off 44 Sharpness Enters Sharpness menu ig On 46 Advanced Menu Enters Main Setup menu On 47 View Facto
2. Menu Description Sub menu Description Default Setting Exit Exits the menu White Balance Maintains proper color reproduction Extended ATW Adjusts camera color Extended as the color temperature of a scene using extended range ATW changes For example from daylight ATW Adjusts camera color constantly to fluorescent lighting Indoor W B Optimizes camera color for typical indoor conditions Outdoor W B Optimizes camera color for typical outdoor conditions AWB Hold Sets the camera s color settings for the current scene Manual Allows a user to adjust the Red and Blue gain Sliding scale 1 to 100 Outdoor Auto Automatically adjusts the white balance to reduce the dark tones at dawn or dusk Sodium Lamp Optimizes the sodium vapor light to restore objects to their original color Sodium Lamp Auto Automatically adjusts for sodium vapor light to restore objects to their original color Gain Control Electronically brightens darker scenes Auto or OFF AUTO which may cause graininess in low light scenes Max Gain Level Adjusts the maximum gain level that Sliding scale 4 the gain control adjusts to when set to 1 to 6 AUTO 1 8db 2 12db 3 16db 4 20db 5 24db 6 28db Sharpness Adjusts the sharpness level of the Sliding scale 12 picture 1 to 16 Synch Mode Sets the type of synchronization mode INTERNAL Synchronizes camera to an INTERNAL for the camera i
3. Display Setup Accesses adjustable display settings such as OSD sector blanking and privacy masking Communication Accesses communication settings such as AutoBaud and Bilinx Setup Alarm Setup Accesses the alarm settings such as inputs outputs and rules Language Displays the language Advanced Accesses the advanced features menu including Stabilization AutoTrack Sensitivity Camera Height and Virtual Masking Diagnostics Displays the status of diagnostic events NOTICE To select the Exit Menu item from anywhere in the current menu use the Zoom command 2 2 Camera Setup Menu The Camera Setup Menu provides access to camera settings that can be changed or customized Menu items marked with an asterisk are the default settings Camera Setup Pre Comp Exit White Bal EXT ATW Gain Control AUTO Max Gain Level 6 4 Sharpness 12 Synch Mode Internal Line Lock Delay 0 Backlight Comp OFF WDR OFF Shutter Mode Auto SensUP Shutter 1 60 Auto SensUP Max 15x Night Mode AUTO Night Mode Color OFF Night Mode Threshold 55 Restore Defaults Factory Setting WDR camera only Focus Iris Select 1 F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera On Screen Display Menu Navigation en 11 Camera Setup Menu Choices
4. 2 0 2012 06 8 en Getting Started AutoDome 600 Series Analog PTZ Camera 1 4 Setting Passwords Passwords are used to control access to locked command menus Unlocked commands are available to all users Passwords are four 4 digits in length 1 4 1 Special Passwords Password Security Level 0000 default Enables security and requires a user to enter the unlock command OFF 90 ENTER before invoking a locked command 9999 Disables all security and allows all users to access locked commands To set or change a password locked command 1 Press OFF 90 ENTER to turn off the command lock 2 Press SET 802 ENTER to access the password menu 3 Tilt the joystick up or down to choose a number Tilt the joystick right to move to the next number position 4 Follow the on screen instructions and save the password You receive an on screen confirmation F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera On Screen Display Menu Navigation en 9 2 On Screen Display Menu Navigation The AutoDome is programmed through the on screen display OSD menus To access the OSD menus you must open the main Setup Menu Menu items marked with an asterisk are default settings unless otherwise noted NOTICE After a period of 4 5 minutes of inactivity a menu times out and exits without warning Some unsaved settings in the current menu can be lost 2 1
5. Setup Menu The main Setup Menu provides access to all programmable AutoDome settings It is a locked menu that requires the user to turn off the command lock To open the main Setup Menu locked command 1 Press OFF 90 ENTER to turn off the command lock 2 Press ON 46 ENTER to access the Main Menu 3 Use the joystick to highlight a menu item 4 Press Focus Iris to open a menu 5 Follow the on screen instructions NOTICE The AutoDome displays only those menus applicable to the particular AutoDome Series configuration Use the joystick to navigate through the menu and the Focus Iris keys to make a selection Setup Menu Exit Camera Setup Lens Setup PTZ Setup Display Setup Communication Setup Alarm Setup Language Advanced Diagnostics Focus Iris Select Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 10 en On Screen Display Menu Navigation AutoDome 600 Series Analog PTZ Camera Setup Menu Choices Menu Description Exit Exits the menu Camera Setup Accesses adjustable camera settings such as white balance gain sharpness sync line lock backlight shutter and night mode Lens Setup Accesses adjustable lens settings such as focus iris zoom speed and digital zoom PTZ Setup Accesses adjustable pan tilt zoom PTZ settings such as Autopan tours PTZ speed inactivity period AutoPivot and tilt limits
6. 01U 270 005 2 0 2012 06 56 en Troubleshooting Guide AutoDome 600 Series Analog PTZ Camera No camera control Ensure that the keyboard and monitor are set to the correct same camera number If O K then Check that the camera address is properly set Enter ON 997 ENTER to display the camera address If address is not set or is incorrect then Set the camera address using FastAddress ON 998 ENTER If O K then Check that the Amber LED on the AutoDome CPU turns on when receiving pan tilt commands from the controller keyboard The Amber LED indicates control is being received Amber LED on AutoDome CPU Module Flash Sequence Off No incoming communications or no power Solid for 2 seconds Receiving good data Fast blinking Lost packet s If amber LED does not light when given PTZ commands then Check if other cameras on the system can be controlled If not check the controller and wiring connections If O K then Check that the RS 232 485 selector switch is properly set to the proper protocol If O K then Ensure that all Biphase Bilinx or RS 232 485 wires are properly connected See the VG5 AutoDome Installation Manual If O K then Check if you can access the AutoDome OSD menus ON 46 ENTER If O K then Confirm that the AutoDome passes homing SET 110 ENTER If AutoDome fails homing then Contact Bosch Technical Support Intermittent c
7. AUTO ON 43 ENTER If O K then Check that the Auto Iris Level is set to the appropriate level ON 11 ENTER If O K then Check that the video coax is terminated with 75 Q only at the head end Double termination causes dark video If O K then Go to the Camera Setup Menu and increase the Pre Compensation setting If O K then Check that the camera lens cover is removed If O K then Check that the maximum coax distance has not been exceeded See the VG5 AutoDome Installation Manual If O K then Restore all camera settings ON 40 ENTER Colors are not correct Reset the White Balance to the appropriate selection ON 30 ENTER If O K then Go to the Camera Setup Menu and increase the Pre Compensation setting If O K then Check that the maximum coax distance has not been exceeded See the VG5 AutoDome Installation Manual If O K then Restore the default settings ON 40 ENTER Background is too bright to see subject Turn on backlight compensation ON 20 ENTER Video is rolling noisy or distorted Ensure that the Synch Mode is set to Internal OFF 42 ENTER If O K then Check that the maximum coax distance has not been exceeded See the VG5 AutoDome Installation Manual If O K then Check the integrity of all BNC connectors and splices Note Connecting a network cable to the interface board of a non IP AutoDome c
8. Exits the menu Command Lock Allows or prohibits accessing locked commands If password is locked set you are prompted to enter the password Bosch Menu locked Accesses the full AutoDome configuration menu and all AutoDome settings Camera Setup Accesses the White Balance and Night Mode camera settings PTZ Setup Accesses the tours tour periods scan speed edit presets limit stops recording and AutoPivot settings Edit Password locked Changes the password FastAddress locked Sets or changes a camera address F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Pelco On Screen Menus en 37 Menu Description Exit Exits the menu Software Version Displays the current software versions Ack and Reset Alarms Acknowledges and resets active alarms Restore All Settings Restores all settings to their original default setting locked Reset All Memory Clears all settings including scene shots tours and recordings locked stored in the AutoDome memory NOTICE After a period of 4 5 minutes of inactivity the OSD menu times out and exits without warning Some unsaved settings can be lost 5 1 1 Command Lock locked The Pelco Command Lock Menu allows or prohibits the use of locked commands The default setting is ON NOTICE If the Command Lock is set to ON a
9. Expand Output Options then click Output Option 5 4 Select Tracking from the Type drop down list 5 Click Output Option 6 6 Select Shot from the Type drop down list F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Advanced Features en 47 10 11 12 13 14 15 Type the number 1 or use the slide bar to specify shot number 1 Shot numbers must be set prior to configuring an alarm rule See Section 3 2 Setting Preset Shots page 26 for instructions The AutoDome moves to this preposition when the alarm rule is true Display a Alarm F Input Options Input Option 1 Input Option 2 Input Option 3 Input Option 4 Input Option 5 Input Option 6 Input Option 7 Input Option 8 Input Option 9 Input Option 10 Input Option 11 Input Option 12 Output Options Output Option Output Option 2 Output Option 3 Output Option 4 Output Option 5 Output Option 6 Output Option 7 Output Option 8 Output Option 9 Output Option 10 Nutan Antinn 11 lt gt Figure 7 3 Output Option 6 Configuration Expand Alarm Rule then click Alarm Rule 1 Click the Yes radio button to enable the rule Type the number 1 or use the slider bar to select 1 for the Input option Select Alarm Input 1 from the Input Option drop down list Ensure that the Output number is set to 1 Select Shot 1 from the Output Options drop down list This option instructs t
10. Group 8 IN OUT 694 695 696 697 698 699 700 701 702 703 792 OMANDORWBNE pH F 01U 270 005 2 O 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Index en 65 Index Symbols ENTER 7 Numerics 33 PRESET 35 34 PRESET 35 80 PRESET 35 81 PRESET 35 82 PRESET 35 92 PRESET 35 93 PRESET 35 94 PRESET 35 95 PRESET 35 36 96 PRESET 35 97 PRESET 35 98 PRESET 35 99 PRESET 35 A ack 37 39 acknowledge 37 acknowledge alarm 39 adjusting AutoDome orientation 14 brightness 15 camera height 23 vertical position 15 Advanced Feature Setup menu 10 22 camera height 23 virtual masking 23 AES 12 alarm relay 19 alarm rule 44 Alarm Setup menu 10 18 AutoTrack 18 Aux Off 18 Aux On 18 input setup 18 inputs 1 7 18 inputs 8 12 18 motion detection 18 normally closed supervised contact 18 normally open dry contact 18 normally open supervised contact 18 Shot 18 alarm status 24 American Dyamics FastAddress 29 American Dynamics 29 audio cable 60 gain 61 line level 61 microphone 60 61 quality 60 61 auto focus 13 auto iris 13 auto iris level 13 Auto SensUP 12 autobaud 17 33 AutoDome orientation 14 automatic white balance 11 AutoPan 49 autopan 14 26 AutoPivot 14 36 39 AutoScan 14 35 AutoSensUP maximum 12 AutoTrack 18 19 48 camera height 48 field of view recommendations 49 light conditions 49 mount recommendations 48 o
11. Security Systems Inc AutoDome 600 Series Analog PTZ Camera On Screen Display Menu Navigation en 25 2 11 1 Alarm Status Submenu This menu displays the status of the alarm inputs and alarm outputs Alarm Status Exit Alarm Input 1 High Alarm Input 2 High Alarm Input 3 Open Alarm Input 4 Open Alarm Input 5 Open Alarm Input 6 Open Alarm Input 7 Open Alarm Output 1 Open Focus Iris Save and Exit Menu Description Options Exit Saves and exits the menu Alarm Input 1 7 Displays the status of alarm inputs 1 through 7 High Low Open Normally Open Closed Normally Closed Alarm Output Displays the status of the alarm output Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 26 en Common AutoDome User Commands unlocked AutoDome 600 Series Analog PTZ Camera 3 3 1 3 2 Common AutoDome User Commands unlocked This chapter details the commonly used Bosch keyboard setup commands See Section 6 Keyboard Commands by Number Page 41 for a complete list of commands Setting AutoPan Mode AutoPan mode pans the AutoDome camera 360 or pans between user defined limits when programmed The AutoDome camera continues to pan until stopped by moving the joystick To pan 360 1 Press ON 1 ENTER 2 Move the joystick to stop the pan To set left and right pan limits 1 Move the camera to the starting position and press SET 1
12. Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 4 en Table of Contents AutoDome 600 Series Analog PTZ Camera 5 1 2 Bosch Menu locked 37 5 1 3 PTZ Setup unlocked 38 5 1 4 Other Menus 39 6 Keyboard Commands by Number 40 7 Advanced Features 44 7 1 Alarm Rules 44 7 1 1 Controlling Alarm Rules 44 7 1 2 Alarm Rule Examples 44 7 2 AutoTrack Operation 48 7 2 1 AutoTrack Settings and Recommendations 48 7 2 2 AutoTrack Optimization 49 7 3 Virtual Masking 50 7 4 Privacy Masking 50 5 Motion Detection with Region of Interest Preset positions 90 through 99 51 7 6 Image Stabilization 51 7 7 Pre position Tour 51 7 8 Azimuth Elevation and Compass Directions 52 7 8 1 Setting the Azimuth Zero Point 52 7 8 2 Displaying Azimuth Elevation and Compass Headings 53 7 9 AutoHome Recalibration Commands and Settings 53 7 9 1 AutoHome Recalibration Operation 54 7 9 2 Using the AutoHome Recalibration 54 8 Troubleshooting Guide 55 8 1 VG5 AutoDome Operation and Control 55 8 2 VG5 Series AutoDome Audio 59 9 User Command Table 62 A Appendix FastAddress Conversions 64 Index 65 F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Getting Started en 5 1 1 1 1 2 Getting Started Install and wire the AutoDome according to the VG5 AutoDome Installation Manual A typical system includes a keyboard matrix switcher monitor and appro
13. and then press the FOCUS or the IRIS button to clear any currently saved Fast Address Move the joystick to highlight Exit Without Change to exit the FastAddress menu without saving any changes FastAddress FastAddress Not Set Save as FastAddress Clear Current FastAddress Exit Without Change Focus Iris Select Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 32 en Alternative Control Protocols AutoDome 600 Series Analog PTZ Camera 4 1 2 6 The on screen display menu confirms that the VG4 AutoDome stored the FastAddress and then returns to the Main menu with the new Fast Address displayed Move the joystick to highlight EXIT and then press FOCUS or IRIS to exit the menus New Fast Address Saved Setup Menu Exit Command Lock OFF Bosch Menu Camera Setup PTZ Setup Edit Password FastAddress 3 Software Version Ack and Reset Alarms Restore All Settings Factory Setting Focus Iris Select Using a Pelco Controller This section provides instructions to set a FastAddress with a Pelco keyboard or controller An AutoDome with an address set to 0 responds to commands set to any address Pelco P protocol must use addresses 1 to 32 Pelco D protocol must use addresses 1 to 254 NOTICE A previously configured AutoDome with an address above 32 Pelco P upper limit or 254 Pelco D upper limit can be used without re
14. for this menu only F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera On Screen Display Menu Navigation en 15 2 5 Display Setup Menu Provides access to display settings that can be changed or customized Menu items with an are the default settings Display Setup Exit Title OSD MOMENTARY Camera OSD ON Display Adjust Sector Blanking Privacy Masking Edit Sector Title Edit Scene Title Restore Defaults Factory Setting Focus Iris Select Display Setup Menu Choices Menu Description Sub menu Description Default Setting Exit Saves and exits the menu Title OSD Controls how the OSD displays OFF Titles are hidden MOMENTARY sector or shot titles ON Titles are displayed continuously MOMENTARY Titles are displayed for a few seconds then disappear from the screen Camera OSD Controls how the OSD displays OFF or ON ON camera response information such as Digital Zoom Iris open close and Focus near far Display Adjust Adjusts the text brightness and Exit Exits the menu vertical position of the on screen Up Moves screen title up title Down Moves screen title down Brighter Brightens the intensity of the on screen text Darker Darkens the intensity of the on screen text Azimuth Displays azimuth elevation On Displays azimuth elevation readings OFF values Off Hides azimuth el
15. scale 5 sec presets during the tour 3 sec to 10 min Tour 2 Period Changes dwell time between Sliding scale 5 sec presets during the tour 3 sec to 10 min PTZ Fixed Speed Sets pan and tilt soeed when Sliding scale 4 controlled by a fixed speed 1 to 15 controller Inactivity Selects the mode that an Scene 1 Returns to Preset 1 OFF AutoDome reverts to after the Prev Aux Returns to previous activity such period of inactivity set in the as Aux commands 1 2 7 8 50 or 52 inactivity period OFF Remains on the current scene indefinitely Inactivity Period Sets the time period of inactivity Sliding scale 2 min before the above action occurs 3 sec to 10 min AutoPivot Automatically rotates the camera OFF or ON ON 180 when following a subject traveling directly beneath the camera AutoDome Automatically rotates the video INVERTED or NORMAL NORMAL Orientation 180 Freeze Frame On Holds a preposition video frame OFF or ON ON Preposition while moving to another preposition Tilt Up Limit Sets the upper tilt limit of the camera Use joystick to move to a scene Azimuth Zero Sets the zero degree pan position Use the joystick to move to a scene that you want to set as the zero degree pan position and as the North compass heading Refer to Section 7 8 Azimuth Elevation and Compass Directions page 52 Restore Defaults Restores the default setting
16. the Bosch FastAddress method The camera automatically detects the address being transmitted by the Sensormatic RS 422 control system and adjusts the camera accordingly Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 30 en Alternative Control Protocols AutoDome 600 Series Analog PTZ Camera Setting the FastAddress with an AD Manchester or AD Sensormatic RS 422 Keyboard Enter the AutoDome Setup menu using 66 Preset Shot on most AD Sensormatic RS 422 keyboards Note Based on your keyboard model it may be necessary to enter the PROGRAMMING mode prior to entering this command Move the joystick to highlight the Command Lock menu Note The first time the VG4 is set up out of the box the Command Lock feature is set to OFF for the first two 2 minutes of operation and then reverts to the ON setting ty 3 Setup Menu Exit Command Lock OFF Bosch Menu Camera Setup PTZ Setup Edit Password FastAddress Not Set Software Version Ack and Reset Alarms Restore All Settings Factory Setting Focus Iris Select Press the FOCUS or the IRIS button to turn Command Lock to OFF Move to the FastAddress menu and press the FOCUS or the IRIS button to open the menu Use the joystick to re enter the 6 digit factory set Unique Identifier displayed for the VG4 AutoDome See example as follows Enter FastAddress FastAddress Not Set Unique Identifier 000000 Continue
17. the person passes behind a Privacy Mask When used with Virtual Mask it is able to ignore predefined areas of background motion You can manually start AutoTrack or program the AutoDome to automatically turn on AutoTrack Manual Enter the keyboard command ON 78 ENTER In Pelco Mode open the Main menu select the Advanced menu and then select AutoTrack On Automatic During a pre position tour During AutoPan AutoDome activates AutoTrack after a period of Inactivity Return to Scene 1 or Return to Previous Aux if AutoTrack is programmed for these activities NOTICE For proper operation AutoTrack requires that the camera height be set in the software Open the Bosch Main menu select the Advanced menu and select Camera Height to enter the height 7 2 1 AutoTrack Settings and Recommendations AutoTrack operates by recognizing an individual in motion and zooms in to approximately 50 of the field of view for an average target height of six feet In addition to the camera height other factors may interfere with AutoTrack operation Setting the Camera Height To ensure smooth tracking set the Camera Height accurately Bosch recommends a minimum camera height of 3 6 m 12 ft Press OFF 90 ENTER to turn off the command lock Press ON 46 ENTER to access the Main Menu Use the joystick to highlight the Advanced menu Press Focus Iris to open the menu Highlight the Camera Height option and press the Focus Iri
18. 0 ENTER 26 SET 802 ENTER 8 Shot 18 26 Show Shot 6 store 26 synchronization mode 35 unlocked 26 user commands 26 zero pan 35 Communication Setup menu 10 17 autobaud 17 baud rate 17 Bilinx 17 compass 15 52 Configuration Tool for Imaging Devices 24 configuring alarms 10 camera height 23 rules 20 constant focus 13 constant iris 13 CTFID 24 custom tour editing 27 setting dwell time 27 Tour Period menu 27 custom tour 2 27 D defining command outputs 19 input commands 18 physical inputs 18 physical outputs 19 rules 20 diagnostics 24 Diagnostics menu 10 23 alarm status 24 BIST 24 CTFID access 24 high temperature events 24 homing events 24 homing failed 24 internal temperature 24 low temperature events 24 low volt events 24 power up events 24 restart events 24 security access 24 video loss events 24 digital zoom 13 display adjust 15 Display Setup menu 10 15 azimuth 15 camera OSD 15 compass 15 display adjust 15 Elevation 15 privacy masking 16 sector blanking 16 title OSD 15 displaying camera response information 15 sector titles 15 shot titles 15 software version 39 titles 15 dwell period 27 dwell time 14 E editing custom tour 39 password 36 39 presets 39 standard tour 39 Elevation 15 elevation 52 Enter key 6 extended ATW 11 F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Index en 67 F FastAddress 7
19. 01 ENTER to set the left limit 2 Move the camera to the end position and press SET 102 ENTER to set the right limit To start AutoPan between limits 1 Press ON 2 ENTER 2 Move the joystick to stop the pan Setting Preset Shots Preset shots are saved camera positions Shots are saved as scenes therefore the terms SHOT and SCENE are used interchangeably To set a Shot 1 Move the camera to the position you want to save 2 Press SET ENTER where can be a number from 1 to 99 that identifies the camera position of the scene 3 To specify a title for the shot see the procedure below To view a Shot gt Press SHOT ENTER where is the number of the scene position you want to view To store or clear a Shot 1 Press SET 100 ENTER to access the Store Clear Scene Menu 2 Follow the on screen instructions To disable overwrite confirmations If you overwrite a preset shot the AutoDome issues a confirmation message prompting you approve the overwrite To disable this confirmation message issue the OFF 89 ENTER command F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Common AutoDome User Commands unlocked en 27 3 3 3 4 Specifying a Shot or a Sector Title The AutoDome provides an alphanumeric character palette used to specify a title for a shot scene or for a sector zone 1 To specify a title navigate to the shot or scene fora sh
20. 29 32 35 36 39 setting with a Pelco Controller 32 setting with an American Dynamics Controller 29 with American Dynamic protocol 29 with Pelco protocol 29 FastAddress with Sensormatic protocol 29 focus speed 13 Function key 6 G gain 11 61 gain control maximum level 11 H high temperature events 24 threshold 24 homing 5 events 24 failed 24 image stabilization 51 inactivity 14 accessing 28 mode 28 operation 28 period 14 Inactivity Mode menu 28 indoor white balance 11 input commands 18 inputs 1 7 18 inputs 8 12 18 inputs setup 18 internal temperature 24 iris speed 13 K keyboard commands 40 ENTER 7 Aux Off 6 18 19 Aux On 6 18 19 Command key 6 Enter key 6 Function key 6 OFF 90 ENTER 8 28 ON 997 ENTER 7 ON 998 ENTER 7 ON 999 ENTER 7 ON 9 ENTER 28 Set 26 Set Shot 6 SET 100 ENTER 26 SET 802 ENTER 8 Shot 26 Shot Shot 6 L Language menu 10 22 Lens Setup menu 10 12 auto focus 13 auto iris 13 auto iris level 13 constant focus 13 constant iris 13 digital zoom 13 focus speed 13 iris speed 13 manual focus 13 manual iris 13 maximum zoom speed 13 spot focus 13 light conditions 49 limit stops 35 36 39 line level 61 line lock 11 35 low temperature events 24 threshold 24 low volt events 24 M Manchester 29 manual focus 13 iris 13 masking privacy 16 virtual 23 maximum zoom speed 13 menus Advanced Feature Setup 10 22 Alarm Setup 18 Bosch 37 Camera Setup 10 38 Comman
21. AUX ON OFF or AUX OFF SET or SET SHOT SHOT or SHOW SHOT NOTICE The convention used for control key commands in this manual is ON OFF SET and SHOT Refer to your keyboard manual for the key naming conventions Command numbers range from 1 to 999 See Section 6 Keyboard Commands by Number page 40 for a complete list of keyboard commands The Enter key can also be labeled with the symbol For example the keyboard command to make the AutoDome pan 360 continuously is ON 1 ENTER press the ON key then press the number 1 key and then press ENTER F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Getting Started en 7 1 3 Setting the Camera Address Once the AutoDome power is turned on and homing is complete you must set the camera address You may also want to assign a password and customize some of the AutoDome default settings NOTICE You do not need to set a camera address if using Bilinx or Ethernet communication See the VG5 AutoDome Installation Manual to configure an AutoDome for Bilinx or Ethernet operation 1 3 1 FastAddress FastAddress is an AutoDome feature that allows you to set or change a camera address using the keyboard and on screen menus There are three 3 FastAddress commands ON 999 ENTER Displays and programs all cameras without an address in the system NOTICE If a keyboard is set to a camer
22. AutoDome 600 Series Analog PTZ Cam era VG5 600 Series BOSCH AutoDome 600 Series Analog PTZ Camera Table of Contents en 3 Table of Contents 1 1 1 2 1 2 1 1 2 2 1 3 1 3 1 1 4 1 4 1 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 2 11 2 11 1 3 1 3 2 3 3 3 4 3 5 3 6 4 1 4 1 1 4 1 2 4 2 4 2 1 4 2 2 4 2 3 4 2 4 5 1 5 1 1 Getting Started 5 Powering On 5 Establishing AutoDome Control 5 Basic Keyboard Operation 6 Keyboard Commands 6 Setting the Camera Address 7 FastAddress 7 Setting Passwords 8 Special Passwords 8 On Screen Display Menu Navigation 9 Setup Menu 9 Camera Setup Menu 10 Lens Setup 12 PTZ Setup Menu 13 Display Setup Menu 15 Communication Setup Menu 17 Alarm I O Setup 18 Rule Setup Menu 20 Language Menu 22 Advanced Feature Setup Menu 22 Diagnostics Menu 23 Alarm Status Submenu 25 Common AutoDome User Commands unlocked 26 Setting AutoPan Mode 26 Setting Preset Shots 26 Specifying a Shot or a Sector Title 27 Configuring Preposition Tours 27 Programming the Inactivity Operation 28 Recording Tours 28 Alternative Control Protocols 29 Setting FastAddress with Alternative Protocols 29 Using an American Dynamics Controller 29 Using a Pelco Controller 32 Pelco Protocol Mode 33 Hardware Configuration 33 Pelco Keyboard Commands 34 Pelco Keyboard Commands 34 Special Preset Commands 35 Pelco On Screen Menus 36 Setup Menu 36 Command Lock locked 37 Bosch
23. Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Troubleshooting Guide en 59 8 2 VG5 Series AutoDome Audio The following diagram illustrates the path for audio transmissions between a microphone AutoDome and a computer that plays the audio Audio Connections with an VG5 600 Series AutoDome In this illustration the VG5 600 Series AutoDome connects to a Bosch Video Audio IP Encoder via a coaxial cable The computer that plays the audio is connected to the encoder via an Ethernet cable Figure 8 1 Typical Audio Connections for an Analog AutoDome Microphone 6 Audio In 2 Coaxial Connection Microphone to Bosch 7 Video In Video Audio Encoder 10 m 33 ft maximum distance 3 VG5 600 Series AutoDome 8 Ethernet Connection Bosch Video Audio Encoder to a PC 4 Coaxial Connection VG5 600 Series 9 Computer with Bosch DiBos Software Autodome to a Bosch Video Audio Encoder 5 Bosch Video Audio Encoder Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 60 en Troubleshooting Guide AutoDome 600 Series Analog PTZ Camera Problem Solution No Audio Check the computer receiving the audio from the VG5 AutoDome or from the IP Encoder Check the computer s audio settings Ensure that the sound levels are at an audible level Check the computer s a
24. Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 18 en On Screen Display Menu Navigation AutoDome 600 Series Analog PTZ Camera 2 7 Alarm I O Setup The Alarm Setup Menu provides access to the Alarm I O Setup Menu to establish the alarm inputs and outputs and to configure alarm rules Alarm I O Setup Inputs Setup Exit Exit Inputs Setup 1 Alarm Input 1 N C S Outputs Setup 2 Alarm Input 2 N O S Physical Rule Setup 3 Alarm Input 3 N O Input 1 7 Restore Defaults 4 Alarm Input 4 N C 5 Alarm Input 5 N O 6 Alarm Input 6 N C 7 Alarm Input 7 N O 8 NONE 9 NONE 10 NONE Physical 11 NONE Output 9 12 12 NONE Focus Iris Select Type Focus Iris Select Right Left Select Mode Alarm Setup Menu Choices Menu Description Sub menu Description Default Setting Exit Saves and exits the menu Inputs Setup Defines physical inputs or events and commands that can be used in a rule There are twelve 12 alarm inputs available Inputs 1 7 Defines the type of physical input N O Normally open dry contact N O N C Normally closed dry contact N C S Normally closed supervised contact N O S Normally open supervised contact Inputs 8 12 Defines input commands that can be NONE No command defined NONE used in a rule Command inputs can also be customized by using non assigned keyboard command numbers Aux On Responds to a s
25. ESET 35 92 PRESET 35 93 PRESET 35 94 PRESET 35 95 PRESET 35 36 96 PRESET 35 97 PRESET 35 98 PRESET 35 99 PRESET 35 AutoScan 35 FastAddress 35 frame scan 35 limit stops 35 PRESET 34 preset tour 35 random scan 35 synchronization mode 35 zero pan 35 Pelco menu Camera Setup 38 Other 39 PTZ Setup 38 Setup 29 Pelco menus Other 39 Pelco Other menu ack 39 acknowledge alarm 39 FastAddress 39 password 39 reset alarm 39 Pelco protocol address guidelines 32 Pelco D 33 Pelco P 33 Pelco PTZ menu AutoPivot 39 PTZ Setup custom tour 39 Pelco PTZ Setup menu edit standard tour 39 limit stops 39 presets 39 recordings 39 scan speed 39 Pelco Setup menu ack alarm 37 Bosch menu 36 camera setup 36 command lock 36 FastAddress 36 password 36 reset alarm 37 Pelco D 33 Pelco P 33 physical inputs 18 F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Index en 69 playback Recording A 28 Recording B 28 power up events 24 pre compensation 12 Preposition Tour custom 27 freeze frame 14 standard 27 preset shot 26 preset tour 35 previous Aux 14 privacy masking 16 50 protocol alternative 29 American Dynamics 29 Bilinx 17 Manchester 29 Pelco 33 Pelco D 33 Pelco P 33 RS 422 29 Sensormatic 29 PTZ fixed speed 14 setup 10 36 PTZ Setup menu 13 14 38 AutoDome orientation 14 autopan 14 AutoPivot 14 AutoScan 14 Azimuth Zero 14 freeze frame o
26. ET Starts an AutoScan NOTICE Some Pelco controllers do not support all the preset command numbers Consult the specific Pelco controller s documentation for supported preset commands Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 36 en Pelco On Screen Menus AutoDome 600 Series Analog PTZ Camera 5 Pelco On Screen Menus You can program the AutoDome through the Pelco on screen display OSD menus To access the Pelco menus you must configure the AutoDome for Pelco Mode and invoke the Pelco main Setup Menu 5 1 Setup Menu The Pelco main Setup Menu provides access to the programmable AutoDome settings Some menu items are locked and require a system password to use Menu items marked with an are the default settings To open the Pelco main Setup Menu locked commands 1 Press 95 PRESET press the PRESET button for approximately 2 seconds to open 2 Use the joystick to highlight a menu item 3 Press either the Focus or the Iris key to open a menu item 4 Follow the on screen instructions at the bottom of the screen Setup Menu Exit Command Lock OFF Bosch Menu Camera Setup PTZ Setup Edit Password FastAddress Not Set Advanced Software Version Ack and Reset Alarms Restore All Settings Reset All Memory Factory Setting Focus Iris Select NOTICE Use Zoom to select the Exit item from anywhere in a menu Menu Description Exit
27. Exit Joystick Match Identifier 200668 Move the joystick up or down to select the individual number Move the joystick right to move to the next FastAddress number position When completed the FastAddress number entered must match the Unique Identifier displayed See example as follows Enter FastAddress FastAddress Not Set Unique Identifier 200668 r Continue Exit Joystick Match Identifier 200668 F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Alternative Control Protocols en 31 NOTICE If the user does not enter the exact manufacturer Unique Identifer as displayed on screen the FastAddress can not be set and the only option available is to Exit the menu 4 Move the joystick right to highlight Continue Then press the FOCUS or the IRIS button Enter FastAddress FastAddress Not Set Unique Identifier 200668 200668 r Continue Exit Joystick Match Identifier 5 The AutoDome automatically reads the correct Address sent by the controller and is displayed as Save as FastAddress is based on either 1 64 AD Manchester or 1 99 AD Sensormatic RS 422 It is NOT POSSIBLE to change the address that is displayed The following options are available Press the FOCUS or the IRIS button to store the FastAddress number Move the joystick to highlight Clear Current FastAddress
28. Loss Interval Interval 6 72 hours in 6 hour increments Initial Offset 4 20 hours in 4 hour increments Number of Recals Total number of homing recalibrations performed due to loss of home or interval Next Cal Shows the days hours minutes and seconds until the next homing recalibration 2 Set the Recalibration Mode to recalibrate on the loss of home and after every interval Issue the AUX ON 682 command Issue the AUX ON 682 command again Note The AUX ON 682 command must be issued twice only for the initial setup Each subsequent AUX ON 682 command toggles the mode as described in the table above 3 Set the Recalibration Interval by issuing the AUX ON 683 and the AUX OFF 683 commands For example to set the Recalibration Interval to 24 hours issue the AUX ON 683 commands four times 4 Set the Initial Offset Time by issuing the AUX ON 684 and the AUX OFF 684 commands For example to set the Initial Offset Time to 8 hours issue the AUX ON 684 command twice 5 Issue the AUX ON 681 command to enable the recalibration routine F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Troubleshooting Guide en 55 8 Troubleshooting Guide 8 1 VG5 AutoDome Operation and Control Problem Solution No video Check that the Green LED on the AutoDome CPU board is on This LED indicates video from the camera If the Green LED is
29. a number that already has an address that camera also responds to this command ON 998 ENTER Displays and programs all cameras with or without an address in the system ON 997 ENTER Displays the current address status of all cameras in the system simultaneously To set an address for a camera without an address 1 Select the camera number you want to FastAddress The system displays the camera number on the keyboard and the image on the corresponding monitor 2 Press ENTER where is the camera number without an address 3 Press ON 999 ENTER to invoke an on screen display of cameras on the system without an address 4 Follow the on screen instructions You receive an on screen confirmation when the FastAddress is complete To change or clear an address for a camera with an address 1 Select the camera number you want to FastAddress The system displays the camera number on the keyboard and the image on the corresponding monitor 2 Press ENTER where is the camera number with an address 3 Press ON 998 ENTER to invoke an on screen display of all cameras on the system with or without an address 4 Follow the on screen instructions You receive an on screen confirmation when the FastAddress is complete NOTICE FastAddress is stored in nonvolatile memory and does not change if the power is turned off or if the default settings are restored Bosch Security Systems Inc User Manual F 01U 270 005
30. ables the balance white balance INDOOR Sets a default setting if the controller disables white balance Night Mode Switches from color to ON Sets Night Mode on ON Day Night monochrome OFF Sets Night Mode off models only AUTO Sets Night Mode to Auto set 5 1 3 PTZ Setup unlocked The Pelco PTZ Setup Menu provides access to the PTZ settings such as tours scan speed presets limit stops recording and AutoPivot PTZ Setup Exit Edit Tour 1 Edit Tour 2 Tour 1 Period 5 sec Tour 2 Period 5 sec Scan Speed 30 deg sec Edit Presets Limit Stops OFF Recording A Autopivot ON Factory Setting Focus Iris Select F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Pelco On Screen Menus en 39 PTZ Setup Menu Choices Menu Description Sub menu Description Default Setting Exit Exits the menu Edit Tour 1 Accesses the Add Exit Exits the menu Remove Scenes On Scene 1 5 Adds or removes Standard Tour 1 Menu scenes from the Standard Tour Edit Tour 2 Accesses the Edit Custom Exit Exits the menu Tour Menu Scene 1 5 Adds or removes scenes from the Custom Tour Tour 1 Period Changes the length of Sliding scale 3 sec to 10 min 5 sec waiting time between presets Tour 2 Period Changes the length of Sl
31. achieves this clarity without reducing camera sensitivity or picture quality To configure image stabilization open the Main menu select the Advanced menu and then select Stabilization to turn on the feature In Pelco Mode open the Main menu select the Advanced menu and then select Stabilization to turn on the feature 7 7 Pre position Tour The VG5 Series AutoDome features 2 preset tours Each preset scene is saved for playback later Tour 1 is a standard tour that only recalls the scenes in the exact sequence they were shot Scenes can be added or deleted on the tour but the sequence cannot be changed To add or remove scenes on Tour 1 enter the keyboard command SHOT 900 ENTER and follow the on screen instructions Tour 2 is a customizable tour that allows you to rearrange the sequence of scenes on the tour by inserting and deleting scenes To enter the Edit Tour 2 menu enter the keyboard command SET 900 ENTER and follow the on screen instructions Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 52 en Advanced Features AutoDome 600 Series Analog PTZ Camera 7 8 7 8 1 Azimuth Elevation and Compass Directions The VG5 AutoDome allows a user to display the azimuth and elevation position and the compass heading of the camera The AutoDome displays the position data in the lower right corner of the image display These readings are described as Azimuth The pan angle from zero to 359 degre
32. addressing the unit However no two 2 addresses can be the same For example Pelco P addresses above 32 are repeated in multiples of 32 1 33 65 97 are the same Pelco D addresses above 254 are repeated in multiples of 254 1 255 509 763 are the same Setting FastAddress with a Pelco Keyboard 1 Press and hold 95 PRESET for two seconds to open the Pelco Setup menu 2 Move the joystick to select the Command Lock menu 3 Press the FOCUS or the IRIS button to turn Command Lock to OFF 4 Move to the FastAddress menu and press the FOCUS or the IRIS button to open the menu 5 Use the joystick to enter the unique identifier for the VG4 AutoDome Move the joystick up or down to select the number Move the joystick right to move to the next number position 6 Move the joystick right to select Continue Then press the FOCUS or the IRIS button 7 Use the keyboard to enter the FastAddress number Then press the Camera button Note You must first clear an assigned FastAddress number to use the number for a different VG4 AutoDome F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Alternative Control Protocols en 33 4 2 8 Move the joystick down then back up to set the FastAddress number 9 Press the FOCUS or the IRIS button to store the FastAddress number The on screen display menu confirms that the VG4 AutoDome stored the FastAddress number P
33. alarm Input s a Wire the motion detector to Input 1 This circuit is normally open b Wire the gate alarm contact to Input 5 This circuit is normally closed NOTICE For instruction on wiring alarm and relay connections see the AutoDome Modular Camera System Installation Manual 2 From the Inputs Setup menu a Ensure Input 1 the motion detector is set to N O This setting is the default for Input 1 b Ensure Input 5 the gate contact is set to N C 3 Set the alarm Outputs from the Outputs Setup menu a Set Output 5 to OSD b Set Output 6 to Transmit c Set Output 7 to Shot 5 d Set Output 8 to AutoTrack 4 Set up the Alarm Rule for this example use Rule 2 Select the alarm Inputs a From the Rule Setup menu select Rule 2 b Set the first input to Alarm Input 1 The motion detector c Set the second input to Alarm Input 5 The gate alarm contact 5 Select the alarm Outputs a Set the first output to OSD b Set the second output to Shot 5 viewing the fence c Set the third output to AutoTrack and select Latched d Set the fourth output to Transmit a Bilinx signal to the headend 6 Enable the alarm Rule Highlight Enabled and select YES Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 46 en Advanced Features AutoDome 600 Series Analog PTZ Camera Example 3 Advanced Alarm Rule using AutoTrack The following example explains how to set an alarm rule that move
34. amera control Check that only the last AutoDome in a daisy chain configuration is terminated with a 100 O resistor across the biphase terminals If O K then Check that the maximum wire distance has not been exceeded for the control protocol the maximum distance for RS 232 is 50 feet See the VG5 AutoDome Installation Manual If O K then Check that all wiring meets Bosch recommended standards and specifications See the VG5 AutoDome Installation Manual Camera moves when moving other cameras Check that the camera address is properly set ON 997 ENTER If the camera address is not set the AutoDome responds to control commands to any camera on the system If camera address is not set then Invoke the FastAddress Menu to assign a camera address ON 998 ENTER Cannot access user settings Enter the unlock command OFF 90 ENTER This command may require a password Commands automatically lock in 30 minutes F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Troubleshooting Guide en 57 Setting FastAddress with an American Dynamics Keyboard The FastAddress value must match the Unique Identifier for the AutoDome To set the FastAddress on an American Dynamics keyboard refer to Section 4 1 Setting FastAddress with Alternative Protocols page 29 Picture is dark Check that the Gain Control is set to
35. anual F 01U 270 005 2 0 2012 06 6 en Getting Started AutoDome 600 Series Analog PTZ Camera 1 2 1 1 2 2 Basic Keyboard Operation The following tables summarize the basic operations for a standard keyboard and the functions available to control an AutoDome camera Typical Keyboard Features Usage Function Keys Selects a specific control setting Number Keys Inputs a number from O0 to 9 Camera Key Selects a camera number Enter Key Inputs a selection Focus Key Sets the lens focus or makes a menu selection in OSD mode Iris Key Sets the lens iris setting or makes a menu selection in OSD mode Key LEDs Indicates an active key LCD Displays the current status Joystick Controls a pan tilt zoom PTZ AutoDome camera Table 1 1 Typical Keyboard Functions Dome Operation How to control To Pan Side to Side Move the joystick left or right To Tilt Up and Down Move the joystick forward and back To Zoom In Twist the joystick clockwise To Zoom Out Twist the joystick counterclockwise Table 1 2 Typical Keyboard Controls for an AutoDome Camera Keyboard Commands Keyboard control commands are composed of a sequence of three 3 inputs with the following convention 1 a Function key 2 a Command number key s 3 the Enter key Depending on the type of keyboard the control function keys are labeled ON or
36. auses video distortion Remove the network cable from the interface board RJ 45 connector If O K then Contact Bosch Technical Support Day Night camera does not switch automatically when image is dark Check that the Day Night mode is set to AUTO ON 56 ENTER If O K then Set Gain Control to AUTO ON 43 ENTER Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 58 en Troubleshooting Guide AutoDome 600 Series Analog PTZ Camera Inside of Outdoor Pendant bubble is foggy Check the status of the Heater Module ON 66 ENTER If status reports Heater No Power then Turn off the power to the AutoDome Check the FX103 fuse in the Power Supply Box for power 24 V to the heater module If O K then Check all wiring and connector pins to the heater module Low Voltage flashing on monitor display If using a non Bosch power supply confirm that it meets the Bosch AutoDome power ratings See the AutoDome Datasheet for specifications If O K then Check the mains input line voltage If O K then Check that the maximum wire length from the power supply has not been exceeded See the VG5 AutoDome Installation Manual If O K then Measure the AC voltage input to the camera while power is applied to the camera The voltage must be gt 21 VAC to stop the message F 01U 270 005 2 0 2012 06 User Manual
37. ay cause inaccurate compass headings F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Advanced Features en 53 7 8 2 Displaying Azimuth Elevation and Compass Headings You can display only the azimuth elevation readings or only the compass reading or you can display both readings at the same time The AutoDome displays the azimuth elevation readings and the compass heading in the following way 180 45 S where 180 is the Azimuth or the pan location in degrees 45 is the Elevation or the tilt location in degrees S is the compass direction cardinal or intercardinal 1 Press ON 95 ENTER to display the azimuth elevation reading 2 Press ON 96 ENTER to display the compass heading 3 Press OFF 95 ENTER to hide the azimuth elevation reading 4 Press OFF 96 ENTER to hide the compass heading 7 9 AutoHome Recalibration Commands and Settings The AutoHoming routine may be enabled for any site that is experiencing a large amount of shifts in masks prepositions or playback tours This feature adds the following AUX commands to configure and to enable the AutoHome Recalibration feature Function Key Command Number Command Description On Off 680 Homing Recalibration Display Displays the current mode of operation intervals time until the next calibration and the number of recalibrations that have occurred On Turns d
38. creen menu instructions In Pelco Mode open the Main menu select the Advanced menu then select Virtual Masking To setup a Virtual Mask follow the on screen menu instructions NOTICE Draw the mask 10 larger than the object to ensure that the mask completely covers the object as the AutoDome zooms in and out 7 4 Privacy Masking Privacy Masking is used to block out a specific area of a scene from being viewed Mask choices include black white or blurred and can be configured with three four or five corners to cover more complex shapes NOTICE Privacy Masking does not hinder AutoTrack from tracking an object To configure a Privacy Mask open the Main menu select Display Setup and then select Privacy Mask Alternatively enter the keyboard command ON 87 ENTER To setup a privacy mask follow the on screen menu instructions In Pelco Mode open the Pelco Main menu open the Bosch menu select the Display Setup menu and finally select Privacy Masking To setup a privacy mask follow the on screen menu instructions NOTICE Draw the mask 10 larger than the object to ensure that the mask completely covers the object as the AutoDome zooms in and out F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Advanced Features en 51 7 5 Motion Detection with Region of Interest Preset positions 90 through 99 With the VG5 Se
39. d Lock 37 Communication Setup 17 Diagnostics 23 Display Setup 15 Inactivity Mode 28 Language 22 Lens Setup 12 Other 39 other 39 Outputs Setup 18 Pelco 29 36 Setup 29 Pelco Setup 35 PTZ Setup 13 38 Rule Setup 20 Setup 36 37 Tour Period 27 microphone 60 61 motion detection 18 51 N networking baud rate 17 night mode 12 38 color 12 threshold 12 normally closed circuit 19 Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 68 en Index AutoDome 600 Series Analog PTZ Camera normally closed supervised contact 18 normally open circuit 19 normally open dry contact 18 normally open supervised contact 18 O OFF 90 ENTER 8 28 ON 997 ENTER 7 ON 998 ENTER 7 ON 999 ENTER 7 ON 9 ENTER 28 on screen display 9 15 19 OSD 9 15 19 outdoor white balance 11 outputs 1 3 19 outputs 5 12 19 Outputs Setup menu 18 alarm relay 19 AutoTrack 19 Aux Off 19 Aux On 19 normally closed circuit 19 normally open circuit 19 OSD 19 outputs 1 3 19 outputs 5 12 19 transmit 19 P passwords changing 8 security level 8 special 8 peak gain 61 Pelco 29 33 36 Bosch 37 Command Lock 37 FastAddress 32 frame scan 35 keyboard commands 34 menus 29 36 mode 33 night mode 38 PRESET command 34 protocol 33 PTZ Setup menu 36 random scan 35 Setup 36 Setup menu 35 software version 37 39 white balance 38 Pelco keyboard commands 33 PRESET 35 34 PRESET 35 80 PRESET 35 81 PRESET 35 82 PR
40. ecurity Systems Inc User Manual F 01U 270 005 2 0 2012 06 62 en User Command Table AutoDome 600 Series Analog PTZ Camera 9 User Command Table Function Comm Command Description Key No On Off Scan 360 Auto Pan without limits On Off 2 Auto Pan Auto Pan between limits On Off Play Custom Pre position Tour Activate Deactivate On Off Play Pre position Tour Activate Deactivate On Off 14 Set Autopan and Scan Speed Enters speed adjustment slide bar On Off 15 Set Pre position Tour Period dwell Enters dwell adjustment slide bar On Off 20 Backlight Comp Backlight Compensation On Off 24 Stabilization Electronic Stabilization On Off 26 Wide Dynamic Range Activate Deactivate On 47 View Factory Settings View all menu default settings On Off 50 Playback A continuous Activate Deactivate On Off 51 Playback A single Activate Deactivate On Off 52 Playback B continuous Activate Deactivate On Off 53 Playback B single Activate Deactivate On Off 56 Night Mode Menu On Off Auto Day Night only On Off 57 Night Mode Setting Enables Disables Night Mode Day Night only On 62 Pre position Title Menu Enters Pre position Title menu On 64 Alarm Status Enters Alarm Status menu Off 65 Alarm Acknowledge Acknowledge alarm or deactivate physical outputs On 66 Display Software Version Displays software version number On 72 Re initialize Cam
41. ecurity Systems Inc User Manual F 01U 270 005 2 0 2012 06 50 en Advanced Features AutoDome 600 Series Analog PTZ Camera 7 3 Setting AutoTrack Optimization Parameters 1 Press OFF 90 ENTER to turn off the command lock 2 Press ON 46 ENTER to access the Main Menu 3 Use the joystick to highlight the Advanced menu 4 Select the AutoTrack Sensitivity option and change the parameter to Auto or to a value between 1 10 Exit the AutoTrack Sensitivity menu Then exit the Advanced Feature Setup menu Access the PTZ Setup menu 7 Select the AutoPan option and change the parameter to one of the suggested values in the table above Oy 0 8 Exit the AutoPan menu Then exit the PTZ Setup menu and finally exit the Main menu Consistent Light Conditions You may use higher AutoPan speeds in consistent indoor or outdoor ambient light conditions but Bosch recommends not exceeding a speed of more than 15 degrees sec Then modify the AutoTrack Sensitivity setting to reach the optimal results Virtual Masking Virtual Masking is a unique Bosch technology that allows you to create an invisible area that ignores unwanted background motion These invisible masks are similar to privacy zones except that the AutoDome AutoTrack and Motion Detection algorithms can see them To configure a Virtual Mask open the Main menu select the Advanced menu then select Virtual Masking To setup a Virtual Mask follow the on s
42. elco Protocol Mode The Pelco Mode features Auto Baud Detection that automatically detects and adjusts the AutoDome protocol and baud rate to match that of the controller The AutoDome responds to Pelco D or Pelco P protocol commands NOTICE The AutoDome supports only the RS 485 protocol while in Pelco mode It does not transmit responses back to the controller 4 2 1 Hardware Configuration The AutoDome is configured from the factory for RS 485 operation in Pelco Protocol Mode 1 Connect the controller s TX terminals to the AutoDome s TxD terminals See the AutoDome Modular Camera System Installation Manual for complete wiring instructions 2 Pan or tilt the keyboard joystick to confirm that control has been established to the AutoDome approximately five 5 seconds NOTICE If control is not established ensure that the RS 232 RS 485 selector switch is positioned to RS 485 outward toward the LED lights This switch is located on the bottom of the AutoDome CPU board under the camera head and next to the LED lights See Figure 4 1 Figure 4 1 RS 232 RS 485 Selection Switch CPU Module Switch Location LEDs RS485 AJOJ NM e Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 34 en Alternative Control Protocols AutoDome 600 Series Analog PTZ Camera 4 2 2 Pelco Keyboard Commands Pelco control commands are composed of a sequence of two 2 keyboard inp
43. enu that define On Off 1 99 Shot and NONE the rule s inputs A rule can have up to four 4 inputs Output Toggles through a list of valid Alarm Outputs 1 3 and any additional outputs set NONE in the Outputs Setup Menu including Alarm Relay Aux On Off 1 99 Shot OSD Transmit and NONE Some outputs such as Alarm Outputs 1 3 Alarm Relay and Aux On Off can be set to be active for a specific duration of time as follows Seconds 1 5 10 15 or 30 Minutes 1 5 or 10 Follows The alarm follows the alarm rule Latched The alarm stays active until acknowledged NOTICE You can include up to four 4 Input and Output events in a single rule Each input and output however must be true for the alarm s rule to be valid and enabled Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 22 en On Screen Display Menu Navigation AutoDome 600 Series Analog PTZ Camera 2 9 Language Menu The Language Menu provides access to a list of languages to display the on screen menus Language Exit English Spanish French German Portuguese Polish Italian Dutch Focus Iris Save and Exit Language Menu Choices Menu Description Default Setting Exit Saves and exits the menu Choose a language Select a language in which the system displays the on screen menus 2 10 Advanced Feature Setup Menu The Adva
44. era Performs camera lens re initialization functions On Off 78 AutoTrack Turns AutoTrack on or off On Off 81 Alarm Output 1 On Activates output Open Collector Off Deactivates output On Off 82 Alarm Output 2 On Activates output Open Collector Off Deactivates output On Off 83 Alarm Output 3 On Activates output Open Collector Off Deactivates output On Off 84 Alarm Output 4 On Activates output Relay Off Deactivates output On Off 88 Proportional Zoom On Activates proportional zoom Off Deactivates proportional zoom On Off 89 Preposition Confirmation On Issues a message that prompts for approval to overwrite a preposition Off No confirmation message issued On Off 90 Command Lock Unlock On Lock on Off Lock off On Off 95 Display Azimuth Elevation Readings On Displays azimuth elevation readings Off Hides azimuth elevation readings On Off 96 Display Compass Heading On Displays compass heading Off Hides compass heading F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera User Command Table en 63 Tour 1 Function Comm Command Description Key No On Off 100 Record A Activate Deactivate On Off 101 Record B Activate Deactivate On 997 FastAddress display Display current address On 998 FastAddress all units Display and program current address On 999 Fa
45. es in one degree increments An azimuth of zero degrees corresponds to North Elevation The tilt position from zero horizon to 90 degrees camera pointing straight down in one degree increments Compass The cardinal or intercardinal N NE E SE S SW W NW heading in which the camera is pointing The AutoDome uses the azimuth to determine the compass direction The following table shows the azimuth range and its corresponding compass heading Azimuth Range Compass Direction 21 to 65 NE Northeast 66 to 110 E East 111 to 155 SE Southeast 156 to 200 S South 201 to 245 SW Southwest 246 to 290 W West 291 to 335 NW Northwest 336 to 20 N North Setting the Azimuth Zero Point The installer must calibrate the Azimuth Zero point The AutoDome uses the Azimuth Zero point usually set to magnetic North as the zero degree pan position and as the North compass heading The AutoDome then displays the azimuth reading and the compass heading based on the number of degrees from the Azimuth Zero point To set the Azimuth Zero point 1 Determine the North compass heading then move the camera to that position 2 Press OFF 90 ENTER to turn off the command lock if active 3 Press ON 94 ENTER to set the Azimuth Zero point CAUTION Bosch recommends that only the installer calibrate the Azimuth Zero point A recalibration to the Azimuth Zero point m
46. ess Activate Zone Scan display zone titles 92 Aux On Press Deactivate Zone Scan re move zone titles F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Alternative Control Protocols en 35 4 2 4 Special Preset Commands Some Pelco mode preset commands have a special meaning and override the normal Pelco preset function as follows Preset Command Description 33 PRESET Pans the AutoDome 180 Flip 34 PRESET Goes to Zero Pan original home position 80 PRESET Toggles the Synchronization Mode between Line Lock and Internal Pelco Frame Scan This command is available if commands are unlocked using the Main menu 81 PRESET Initiates Preset Tour 1 82 PRESET Initiates Preset Tour 2 92 PRESET Sets the Left pan limit for an AutoScan with Limit Stops enabled 93 PRESET Sets the Right pan limit for an AutoScan with Limit Stops enabled 94 PRESET Initiates a Preset Tour 95 PRESET Enables or disables Limit Stops in the Setup Menu for AutoScan Invokes the Pelco main Setup Menu when pressed for 2 seconds 96 PRESET Stops a scan 97 PRESET Initiates FastAddress Pelco Random Scan 98 PRESET Toggles the Synch Mode between Line Lock and Internal Pelco Frame Scan This command is available only for two 2 minutes after the power is applied and then reverts to normal preset functionality 99 PRES
47. evation readings Refer to Section 7 8 Azimuth Elevation and Compass Directions page 52 Compass Displays compass heading On Displays compass heading OFF Off Hides compass heading Refer to Section 7 8 Azimuth Elevation and Compass Directions page 52 Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 16 en On Screen Display Menu Navigation AutoDome 600 Series Analog PTZ Camera Menu Description Sub menu Description Default Setting Sector Blanking Allows video blanking of selected sectors Available sectors are 1 through 16 Follow the on screen instructions Exit Exits the menu Sector 1 16 Press Focus Iris to blank or clear a sector Privacy Masking Allows masking of sensitive areas Up to 24 privacy masks are available with a maximum limit of eight 8 to a scene Exit Saves and exits menu Mask 1 to 24 masking areas Follow the on screen instructions to set a mask See Section 7 1 Alarm Rules page 44 Restore Defaults Restores the default settings for this menu only Edit Sector Title Allows editing existing Sector Zone Titles Select a sector title to access the character palette See Section 3 3 Specifying a Shot or a Sector Title page 27 for instructions Edit Scene Title Allows editing existing Scene Shot Titles Select a scene title then choose a menu option Edit Scene Title to acces
48. ft Refer to the VG5 AutoDome Installation Manual for more information Poor Audio Check the computer receiving the audio from the VG5 AutoDome or from the IP Decoder Check the computer s audio output card and speakers Play a secondary source of audio on the computer if you hear static then replace the speakers and try again Check the computer s audio output card and speakers Play a secondary source of audio on the computer If you still do not hear audio replace the speakers and try again If O K then Check the Gain settings and the peak gain value a Access the Settings Web page for the IP enabled device b Expand the Encoder Settings link then click Audio Settings c Adjust the Gain level so that the peak value stays within the green area Refer to the VG5 AutoDome Installation Manual for complete information If O K then Check the location of the microphone and the audio cables Line level audio is typically between 700 mV and 2 V so it may be affected by AC power or transmission sources Ensure that there is a maximum at least 1 foot per 100 VAC distance between the microphone and audio cables and the AC source If O K then Verify the cable type and installation used for audio connections between the microphone and the VG5 AutoDome Cable type Coaxial Cable length 10 m 33 ft maximum Refer to the VG5 AutoDome Installation Manual for more information Bosch S
49. h as a Preposition Tour Recording Tours The VG5 AutoDome can make up to two 2 recorded tours A Recorded Tour saves all manual camera movements made during the recording including its rate of pan tilt and zoom speeds and other lens setting changes To Record Tour A 1 Press ON 100 ENTER to start recording a tour 2 Press OFF 100 ENTER to stop recording To playback Recorded Tour A 1 Press ON 50 ENTER to begin continuous playback 2 Press OFF 50 ENTER or move the joystick to stop playback To Record Tour B 1 Press ON 101 ENTER to start recording the tour 2 Press OFF 101 ENTER to stop the tour To playback Recorded Tour B 1 Press ON 52 ENTER to begin continuous playback 2 Press OFF 52 ENTER or move the joystick to stop playback F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Alternative Control Protocols en 29 4 4 1 4 1 1 Alternative Control Protocols The VG5 AutoDome supports three alternative control protocols that allow a user to send commands and to receive information from the AutoDome The VG5 AutoDome supports the following protocols Pelco P Pelco D American Dynamics AD Manchester American Dynamics AD Sensormatic RS 422 The VG5 AutoDome natively supports the two Pelco protocols To use the AD Manchester or the AD Sensormatic RS 422 protocol you must purchase a separate module The module contains
50. he AutoDome to move to pre position shot 1 when Input 1 is true Camera Setting Group 1 Setting Group 2 Yes No Setting Group 3 Setting Group 4 Lens Setting Group 1 Input Setting Group 2 PTZ Setting Group 1 f mi Setting Group 2 Input Option Display Setting Group 1 JAlarmInput1 zf Setting Group 2 Setting Group 3 Alarm Input Options Output Input Option 1 Input Option 2 E Input Option 3 Input Option 4 Input Option 5 Input Optone shota Input Option 7 Input Option 8 Input Option 9 Inm Antinn 10 Enabled Input Options Output Options Output Option Output Period v Eaa Figure 7 4 Alarm Rule 1 Configuration Move the Output slider bar to Output 2 Select Tracking from the Output Option drop down list This option instructs the AutoDome to activate the AutoTrack feature after the input alarm is triggered and after the AutoDome moves to pre position 1 Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 48 en Advanced Features AutoDome 600 Series Analog PTZ Camera 16 Select 5 sec from the Output Period drop down list This option instructs the AutoDome to turn off the AutoTrack feature after five seconds from when the tracked object is out of view 7 2 AutoTrack Operation The AutoDome features enhanced AutoTrack software with more versatility and smoother object tracking AutoTrack continuously follows an individual even if
51. ht mode B W operation in increments of 5 10 is earlier 55 is later Pre Comp Amplifies the video gain to Sliding scale 1 compensate for long distance cable 1 to 10 runs Restore Restores all default settings for this Defaults menu only 2 3 Lens Setup The Lens Setup Menu provides access to lens settings that can be changed or customized Menu items marked with an asterisk are the default settings Lens Setup Exit Auto Focus SPOT Auto Iris CONSTANT Auto Iris Level 8 Focus Speed 2 Iris Speed 5 Max Zoom Speed FAST Digital Zoom ON Restore Defaults Factory Setting Focus Iris Select F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera On Screen Display Menu Navigation en 13 Lens Setup Menu Choices Menu Description Sub menu Description Default Setting Exit Saves and exits the menu Auto Focus Automatically focuses on the CONSTANT Auto Focus is always active even SPOT subject in the center of the while the camera is moving screen MANUAL Auto Focus is inactive manual focus must be used SPOT The camera activates Auto Focus after the camera stops movement Once focused Auto Focus is inactive until the camera moves again Auto Iris Automatically adjusts to MANUAL Iris must be adjusted manually CONSTANT varying light conditions CONSTANT Auto Iris is constantly ac
52. ical results displayed as follows BIST Exit Data Flash Bilinx FPGA Digital I O 1 Digital O2 VCA Homing PASS PASS PASS PASS PASS PASS PASS Internal Temp Displays the current dome temperature High Temp Events Displays the number of times the high temperature threshold is exceeded Highest Temp Displays the highest temperature reached Low Temp Events Displays the number of times the low temperature threshold is exceeded Lowest Temp Displays the lowest temperature reached Security Access Displays the number of times the locked command menu is unlocked CTFID Access Displays the number of times the Configuration Tool is accessed Homing Events Displays the number of times the AutoDome was rebooted Homing Failed Displays the number of times the AutoDome failed to home properly Loss Home Events Displays the number of times the AutoDome lost the home position Home Position Good Displays if the current AutoDome home position is good Displays YES if good Restart Events Displays the number of restart events Low Volt Events Displays the number of times the AutoDome dropped below the acceptable voltage limit Power Up Events Displays the number of power up events Video Loss Events Displays the number of time that video was lost F 01U 270 005 2 0 2012 06 User Manual Bosch
53. iding scale 3 sec to 10 min 5 sec waiting time between presets Scan Speed Changes the Autopan and Sliding scale 1 sec to 60 sec 30 AutoScan speeds sec Edit Presets Modifies preset scenes 1 99 scenes Limit Stops Toggles the Limit Stops for ON or OFF OFF AutoScan Recordings Selects record Pattern 1 or A or B A 2 if normal pattern command does not respond AutoPivot Follows a subject while ON or OFF ON beneath the camera without inverting the picture 5 1 4 Other Menus Menu Description Default Setting Edit Password Sets or displays the password See Section 1 4 Setting Passwords page 8 FastAddress locked Sets or changes the AutoDome address Not Set Software Version unlocked Displays the camera software version Ack and Reset Alarms Acknowledges and resets alarms If there is no active alarm input the OSD displays the following message No Active Alarms Restore All Settings locked Restores all settings to their original factory default settings Reset All Memory locked Restores all settings to their original factory default settings and clears all user programmed settings such as preset scenes and recordings Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 40 en Keyboard Commands by Number AutoDome 600 Series Analog PTZ Camera 6 Keyboard Commands by Number
54. instructions to install any additional hardware and information about additional on screen menus Setting FastAddress with Alternative Protocols The VG5 AutoDome offers remote addressing via the FastAddress capability from a keyboard that uses an alternative protocol The FastAddress feature allows you to instal all domes first then set the addresses via the control system Since it is not necessary to go to the camera s physical location this feature makes it easier to readdress cameras at a later time Using an American Dynamics Controller Prior to setting the FastAddress for each camera all cameras will initially move together After the Unique Identifier is set only the camera that was set with the FastAddress is capable of sending and receiving commands When setting the FastAddress it is important to remember that some American Dynamics Manchester systems use address blocks of 1 to 64 while American Dynamics Sensormatic systems typically use address blocks of 1 to 99 meaning that when the controller keyboard displays video for cameras higher than 64 or 99 the keyboard controller sends a different control code to the camera see Section A Appendix FastAddress Conversions page 64 for conversion charts For example at Camera 65 the American Dynamics Manchester system sends out an address of 1 while the Sensormatic RS 422 system with an address of 100 also sends out an address of 1 It is NOT NECESSARY to convert these numbers with
55. isplay Software Version Displays software version number E On Off 69 Alarm Rule Activation Deactivation On Enables all alarm rules Off Disables all alarm rules On 72 Re initialize Camera Performs camera lens re initialization functions On Off 78 AutoTrack Turns AutoTrack on or off On 79 Camera Height Enters the Camera Height menu On Off 80 Digital Zoom Lock Turns digital zoom on and off On Off 81 Alarm Output 1 On Activates output Open Collector Off Deactivates output On Off 82 Alarm Output 2 On Activates output Open Collector Off Deactivates output On Off 83 Alarm Output 3 On Activates output Open Collector Off Deactivates output On Off 84 Alarm Output 4 On Activates output Relay Off Deactivates output On Off 86 Sector Blanking Enters Sector Blanking menu On Off 87 Privacy Masking Enters Privacy Masking menu On Off 88 Proportional Zoom On Activates proportional zoom Off Deactivates proportional zoom On Off 89 Preposition Confirmation On Isues a message that prompts for approval to overwrite a preposition Off No confirmation message issued On Off 90 Command Lock Unlock On Lock on Off Lock off On Off 91 Lens Polarity Menu On Reverse Off Normal i On Off 92 Lens Polarity Menu On Reverse Off Normal On Off 93 Lens Polarity Menu On Reverse Off Normal a On Off 94 Set Azimuth Zero Point Sets the zero degree pan position Refer to Section 7 8 Azimuth Elevation and Compass Directions page 52 Bosch Securi
56. isplay on Off Turns off the display On Off 681 Homing Recalibration On Enables recalibration This action does not cause the dome to re home immediately Off Disables recalibration On 682 Recalibration Mode Each On command toggles the recalibration mode as follows Recalibrates only on the loss of home position Recalibrates on the loss of home and for every periodic interval On Off 683 Recalibration Interval Changes the homing recalibration interval Intervals are in 6 hour increments up to 72 hours Each On increases interval by 6 hours Each Off decreases interval by 6 hours On Off 684 Initial Offset Time Sets the initial offset time for the recalibration interval The offset time starts after the Homing Calibration is enabled The recalibration interval begins its countdown after the offset time Each On increases offset time by 4 hours Each Off decreases offset time by 4 hours Note The offset time does not take effect until the Homing Calibration is enabled Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 54 en Advanced Features AutoDome 600 Series Analog PTZ Camera 7 9 1 7 9 2 AutoHome Recalibration Operation Recalibration occurs when the AutoDome loses its home position or after the specified time interval has elapsed Once a recalibration event occurs the AutoDome will delay the sta
57. n ROON DOR WNDY 0 99 BLOCK 3 Bosch AD 129 130 131 132 133 134 135 136 137 138 192 OMONDOOABRWNHE pan 2 O D gt Group 3 IN OUT 199 200 201 202 203 204 205 206 207 208 297 OMAONDORWBNE pan 2 o BLOCK 4 Bosch AD 193 194 195 196 197 198 199 200 201 202 256 OMAONDOARWBNE m 2 O A ss Conversion Table for AD Manchester Systems Group 4 IN OUT 298 299 300 301 302 303 304 305 306 307 396 OMANDORWBNE m 2 BLOCK 5 Bosch AD 257 258 259 260 261 262 263 264 265 266 320 OMONDOABRWNHE ar oD K Group 5 IN OUT 397 398 399 400 401 402 403 404 405 406 495 OMONDORWBNE pane na Table 1 2 Address Conversion Table for AD Sensormatic RS 422 Systems BLOCK 6 Bosch AD 321 322 323 324 325 326 327 328 329 330 384 FOOANDOARWNHE 0 64 Group 6 IN OUT 496 497 498 499 500 501 502 503 504 505 594 OMANDOAKRWBNHE BR 2 Co BLOCK 7 Bosc AD h 385 386 387 388 389 390 391 392 393 394 448 FOOANDOOARWBNHRE 0 64 Group 7 IN OUT 595 596 597 598 599 600 601 602 603 604 693 OMONDOARWBNHRE 2 BLOCK 8 Bosc AD h 449 450 451 452 453 454 455 456 457 458 512 OMANDOARWBNE m S oD K
58. n A keyboard ON command NONE output for use in a rule Aux Off A keyboard OFF command Shot Recalls a preset shot OSD An on screen display Transmit Transmits a message back to the head end available with RS 232 serial connections Bilinx and IP AutoDome models NONE No command defined AutoTrack Turns AutoTrack on or off as an output Outputs 5 and 6 set to OSD and Shot 1 Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 20 en On Screen Display Menu Navigation AutoDome 600 Series Analog PTZ Camera 2 8 Rule Setup Menu The Rule Setup Menu shows the status of the rules and lets you add new rules or modify an existing rule The default setting is Empty NOTICE You can program a total of twelve rules You must define the inputs and outputs before you program a rule See Section 2 7 Alarm I O Setup page 18 to configure alarm inputs and outputs Rule Setup Rule 1 Exit Exit 1 Rule 1 Enabled Enabled YES 2 Rule 2 Disabled Input 3 Rule 3 Invalid NONE 4 Rule 4 Empty NONE 5 Rule 5 Empty NONE 6 Rule 6 Empty 7 Rule 7 Empty Output 8 Rule 8 Empty OSD 9 Rule 9 Empty Shot 2 10 Rule 10 Empty Alarm Relay 2 sec 11 Rule 11 Empty NONE 12 Rule 12 Empty 4 Rule 4 Empty Right Left Select Period Time Focus Iris Select Focus Iris Select Type Rule Setup Menu Choices Menu Description Sub menu Descri
59. n preposition 14 inactivity 14 inactivity period 14 previous Aux 14 PTZ fixed speed 14 rule alarm relay 21 Aux Off 21 Aux On 21 enabled 21 follows 21 input 21 OSD 21 output 21 Shot 21 status 20 transmit 21 rule 1 12 20 rule input Shot 21 Rule Setup menu 20 rules 20 S scan speed 36 39 scene 1 14 sector blanking 16 security access 24 level 8 Sensormatic 29 SensUp 12 Set 6 Set command 26 Set Shot 6 SET 100 ENTER 26 SET 802 ENTER 8 settings AutoDome orientation 14 autopan 26 brightness 15 camera height 23 inactivity mode 28 scene 1 14 passwords 8 tilt up limit 14 Preposition Tour 27 R preset shot 26 record 39 rules 20 tour 28 sharpness 11 tour A 28 vertical position 15 tour B 28 Setup menu 9 29 35 36 37 Recording A 28 Advanced Feature Setup 10 playback 28 Alarms 10 Recording B Camera 10 playback 28 Communication 10 region of interest 51 Diagnostics 10 reset alarm 37 39 Display 10 restart events 24 Language 10 RS 422 29 Lens 10 PTZ 10 sharpness 11 Shot 6 clear 26 Set 26 store 26 view 26 Show 6 Show Shot 6 Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 70 en Index AutoDome 600 Series Analog PTZ Camera shutter 12 shutter mode 12 software version 37 software version 39 spot focus 13 stabilization 51 standard tour setting dwell time 27 Tour Period menu 27 synchronization mode 11 35 T tilt up limit 14 titles brightness 15 OSD 15 vertical positi
60. nced Menu provides access to the Advanced Features Setup menus such as image Stabilization AutoTrack Sensitivity and Virtual Masking Menu items marked with an asterisk are the default settings Advanced Feature Setup Exit Stabilization AutoTrack Sensitivity AutoTrack Timeout AutoTrack Timeout Period Camera Height Virtual Masking Restore Defaults Focus Iris Save and OFF Auto OFF 5 min 12 Exit F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera On Screen Display Menu Navigation en 23 Advanced Feature Setup Menu Choices Menu Description Sub menu Description Default Setting Exit Saves and exits the menu Stabilization Turns on video stabilization OFF AutoTrack Sensitivity Sets the sensitivity level of Sliding scale Auto 1 to 20 Auto AutoTrack Where 1 is more sensitive and 20 is less sensitive Auto varies the sensitivity level based on various lighting conditions AutoTrack Timeout Toggles the AutoTrack Timeout When On AutoTrack gives up after the OFF feature Timeout Period if tracking in a confined area for example a tree a flag etc AutoTrack Timeout Enters the AutoTrack Timeout Sliding scale 30 sec 1 to 30 min 5 min Period Period set menu Camera Height Defines the height of the camera for AutoTrack A range from 2 4 m 8 ft to 30 7 m 100 f
61. nd you press Focus or Iris on a locked command the AutoDome displays the on screen message Command is Locked 5 1 2 Bosch Menu locked The Bosch Menu allows full access to the AutoDome main Setup Menu and all AutoDome configuration settings Pelco menu Bosch menu Setup Menu Setup Menu Exit Command Lock OFF Exit Bosch Menu Camera Setup Camera Setup Lens Setup PTZ Setup PTZ Setup Edit Password Display Setup FastAddress Not Set Communication Setup Advanced Alarm Setup Software Version Language Ack and Reset Alarms Advanced Restore All Settings Diagnostics Reset All Memory Factory Setting Focus Iris Select Focus Iris Select Refer to Section 2 On Screen Display Menu Navigation for a complete description of Bosch menus and configuration settings Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 38 en Pelco On Screen Menus AutoDome 600 Series Analog PTZ Camera Camera Setup unlocked The Pelco Camera Setup Menu provides access to camera settings Camera Setup Exit White Bal OUTDOOR Night Mode AUTO Factory Setting Focus Iris Select Camera Setup Menu Choices Menu Description Sub menu Description Default Setting Exit Exits the menu White Sets a default value in OUTDOOR Sets a default setting if OUTDOOR Balance case the Pelco the controller disables white controller dis
62. nternal crystal This choice is recommended if there is noise on the power line LINE LOCK Synchronizes camera to AC power This choice eliminates picture roll in multi camera systems Line Lock Delay Optimizes the LINE LOCK mode to Sliding scale 0 eliminate picture roll in multiphase 0 to 359 power applications Backlight Comp Improves image quality when the On or OFF OFF background illumination level is high WDR Turns the wide dynamic range feature ON OFF or Auto OFF on or off Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 12 en On Screen Display Menu Navigation AutoDome 600 Series Analog PTZ Camera Menu Description Sub menu Description Default Setting Shutter Mode Turns Auto SensUP on or off Auto SensUP or OFF Auto SensUP Shutter Adjusts the electronic shutter speed Sliding scale 1 60 sec AES 60 at extreme left to 1 10000 NTSC or 1 50 sec PAL Auto SensUP Sets the limit for sensitivity when the 15x 7 5x 4x or 2x 15x Max shutter speed is set to Auto SensUP Night Mode Selects night mode B W to enhance ON OFF or AUTO AUTO lighting in low light scenes Night Mode Determines if color processing ON or OFF OFF Color remains in effect while in night mode Night Mode Adjusts the level of light at which the Sliding scale 55 Threshold camera automatically switches out of 10 to 55 nig
63. off then Check that the Red LED on the AutoDome CPU board is slowly blinking This LED indicates power to the AutoDome power supply board and to the CPU Module Red LED on AutoDome CPU MO odule Flash Sequencelndicates 5 sec on 0 5 sec off Normal operation Steady on CPU is locked If the Red LED is on steady then Try cycling the AutoDome power off and on If the Red LED is off then If using a Bosch Pendant Power Supply Box Check that Green LED in Power Supply Box is on This LED indicates mains power through the transformer If the Green LED is off then Turn off the Power Check the FX101 fuse for mains power to the Power Supply Box If O K then Check the FX102 fuse for 24 V power to the AutoDome Pendant If O K then If using a non Bosch power supply Check that the mains power to the power supply box is on If O K then Check that there is 24 V output from the transformer Check the connector on top of the AutoDome housing for bent pins If O K then Check the integrity of all wires and terminal connections to the AutoDome If O K then If there is power to the AutoDome then Remove the camera and CPU modules from the AutoDome housing and check that the Green LED on the housing power supply board is on If the Green LED is off then Check that the fuse on the housing power supply board is good Bosch Security Systems Inc User Manual F
64. on 15 tour custom 39 periods 36 39 preposition 27 preset 35 standard 39 stopping 27 tour 1 27 tour 2 27 Tour 1 period 14 Tour 2 period 14 Tour Period menu 27 U user commands 26 V video loss events 24 virtual masking 23 50 voltage limit 24 W white balance 11 38 Z zero pan 35 F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Index en 71 Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 72 en Index AutoDome 600 Series Analog PTZ Camera F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc Bosch Security Systems Inc 850 Greenfield Road Lancaster PA 17601 U S A www boschsecurity com Bosch Security Systems Inc 2012
65. on Display Displays the current mode of operation intervals time until the next calibration and the number of recalibrations that have occurred On Turns display on Off Turns off the display On Off 681 Homing Recalibration On Enables recalibration This action does not cause the dome to re home immediately Off Disables recalibration On 682 Recalibration Mode Each On command toggles the recalibration mode as follows Recalibrates only on the loss of home position Recalibrates on the loss of home and for every periodic interval On Off 683 Recalibration Interval Changes the homing recalibration interval Intervals are in 6 hour increments up to 72 hours Each On increases interval by 6 hours Each Off decreases interval by 6 hours F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Keyboard Commands by Number en 43 from Tour 1 Locked Function Comm Command Description Key No On Off 684 Initial Offset Time Sets the initial offset time for the recalibration interval The offset time starts after the Homing Calibration is enabled The recalibration interval begins its countdown after the offset time Each On increases offset time by 4 hours Each Off decreases offset time by 4 hours Note The offset time does not take effect until the Homing Calibration is enabled bg On 911 Rem
66. ot set a new shot or view a stored shot then press ON 62 ENTER fora scene move the AutoDome to the scene zone then press ON 63 ENTER Use the joystick to move the cursor to highlight a character Press Focus Iris to select the character Continue to select characters up to 20 until you have created the title To clear a character from the title a Use the joystick to highlight the Clear OR Position Character prompt ON gt oct b Move the joystick left or right until the cursor is below the title character you need to clear c Press Focus Iris to clear the character d Move the joystick up to bring the cursor back into the character palette 6 To save the title a Use the joystick to highlight the Exit prompt b Press Focus Iris to save the title Configuring Preposition Tours A Preposition Tour automatically moves the camera through a series of preset or saved shots The VG5 Autodome has one 1 standard preset tour and one 1 customized preset tour Tour 1 is a standard tour that moves the camera through a series of shots in the sequence they were set Tour 2 is a custom tour that allows you to change the sequence of shots in the tour by inserting and deleting scenes To start Preposition Tour 1 1 Seta series of preset shots in the order that you want the AutoDome to cycle through 2 Press ON 8 ENTER to start the tour The tour then cycles through the series of shots until it is stopped To stop a Preposition T
67. ote Restart Simulates a power cycle Once issued the AutoDome re homes and displays the start up splash screen Set 802 Edit Password Enters the Edit Password menu i Set 899 Reset ALL Restores all settings to original defaults and clears all user programmed settings Set 900 Edit Tour 1 Standard Enters the Standard Tour Scene menu Shot 900 Edit Tour 2 Custom Enters the Custom Tour Scene menu Set Shot 901 999 Adds Removes a Preposition Shot Set Adds preset Shot Removes preset Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 44 en Advanced Features AutoDome 600 Series Analog PTZ Camera 7 7 1 7 1 1 7 1 2 Advanced Features This chapter details the advanced features of the VG5 AutoDome Camera Alarm Rules The AutoDome features a powerful alarm rule engine In its simplest form an alarm rule defines those inputs that activate specific outputs In its more complex form a rule can be programmed to take any combination of inputs and keyboard commands to perform a dome function There are numerous combinations of alarm inputs and outputs that can be programmed into twelve alarm rules Controlling Alarm Rules The AUX 69 command allows a user to enable or disable all alarm rules By default alarm rules are enabled until the OFF 69 ENTER command is issued from a keyboard there is no corresponding menu item for this command Disabling alarms rules does not erase the
68. our gt Press OFF 8 ENTER or move the joystick to stop either type of tour To add or remove scenes to Preposition Tour 1 1 Press SHOT 900 ENTER to access the Add Remove Scenes Menu 2 Use the Focus Iris buttons to add or remove the selected scene from the tour To start custom Preposition Tour 2 gt Press ON 7 ENTER to start a tour The tour cycles through the series of shots in the order they were defined until it is stopped To edit a custom Preposition Tour 2 1 Press SET 900 ENTER to access the Add Remove Menu 2 Press the Focus Iris buttons to add or remove the selected scene To change the dwell period of a tour 1 Press ON 15 ENTER to access the Tour Period Menu 2 Select the tour Tour 1 or Tour 2 and follow the on screen instructions Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 28 en Common AutoDome User Commands unlocked AutoDome 600 Series Analog PTZ Camera 3 5 3 6 Programming the Inactivity Operation You can program the AutoDome to automatically change its operating mode after a period of inactivity To access the Inactivity mode locked command 1 Press OFF 90 ENTER to turn off the command lock 2 Press ON 9 ENTER to access the Inactivity Mode Menu 3 Select one of the following choices Return to Scene 1 Returns the camera position back to the first scene saved in memory Recall Previous Aux Returns the camera to the previous operating mode suc
69. priate wiring connections Please refer to the individual product manuals for complete installation and setup instructions for each of the system components Powering On When you turn the AutoDome power on there is a ten 10 second pause before the dome starts its homing phase During the homing phase the camera pans left and right and tilts up and down It also adjusts the lens focus The entire homing phase lasts approximately 40 seconds and ends with a firmware version screen Bosch Security Sys AutoDome r 600 Series 5 00 00 03 1 05 00 02 Day Night 36X 1 00 00 00 SC Boot 5 00 00 03 FPGA 1 13 01 05 VCA_boot 1 02 00 01 STD Comm No Heater FastAddress Not Set Figure 1 1 Sample VG5 Startup Firmware Version Screen The splash screen displays the type of AutoDome the camera installed the firmware levels for various files and the current IP address for VG5 AutoDome 700 Series models Establishing AutoDome Control The most common ways to interface with the AutoDome are Using a keyboard and on screen display OSD menus This method is the most common and is covered in this manual Using the AutoDome Configuration Tool software running on a PC with Bilinx or the RS 232 485 communication protocol Refer to the CTFID User Manual for instructions Using a PC based graphical user interface GUI such as the Bosch DiBos 8 software Refer to the DiBos 8 User Guide for instructions Bosch Security Systems Inc User M
70. ptimization 49 sensitivity 49 settings 48 with AutoPan 49 Aux Off 6 Aux Off command 18 19 Aux On 6 Aux On command 18 19 AWB hold 11 azimuth 15 52 Azimuth Zero 14 azimuth zero 52 B backlight compensation 11 baud rate 17 Bilinx 17 BIST 24 Bosch menu 36 37 built in self test 24 03 camera height 23 OSD 15 setup 36 camera height 48 Camera Setup menu 10 38 AutoSensUp maximum 12 AWB hold 11 backlight compensation 11 color 12 crystal 11 extended ATW 11 gain control 11 indoor white balance 11 line lock 11 line lock delay 11 maximum gain level 11 night mode 12 outdoor white balance 11 pre compensation 12 sharpness 11 shutter 12 synchronization menu 11 threshold 12 white balance 11 Command key 6 Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 66 en Index AutoDome 600 Series Analog PTZ Camera command lock 36 Command Lock menu 37 commands ENTER 7 33 PRESET 35 34 PRESET 35 80 PRESET 35 81 PRESET 35 82 PRESET 35 92 PRESET 35 93 PRESET 35 94 PRESET 35 95 PRESET 35 36 96 PRESET 35 97 PRESET 35 98 PRESET 35 99 PRESET 35 autopan 26 AutoScan 35 Aux Off 6 18 19 Aux On 6 18 19 clear 26 FastAddress 35 inactivity operation 28 keyboard 40 limit stops 35 OFF 90 ENTER 8 28 ON 997 ENTER 7 ON 998 ENTER 7 ON 999 ENTER 7 ON 9 ENTER 28 Pelco 34 Pelco frame scan 35 PRESET 34 preset shot 26 preset tour 35 random scan 35 recording tours 28 Set 26 Set Shot 6 SET 10
71. ption Default Setting Exit Saves and exits the menu Rule 1 12 Displays the status of arule Enabled The rule inputs and outputs are properly Empty on the right side of the defined and the rule is turned on menu There are four 4 Disabled The rule inputs and outputs are defined but the possible rule statuses rule is turned off Invalid The rule has a missing or invalid input or output Empty The rule has no inputs or outputs defined Selecting a Rule number provides access to its configuration menu The Rule Menu allows you to configure a rule from previously defined alarm inputs and outputs Once an alarm is configured with valid inputs and outputs it can be turned on or off enabled or disabled through its configuration menu F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera On Screen Display Menu Navigation en 21 Rule Choices outputs set in the Alarm I O Setup gt Outputs Setup Menu that defines a rule s outputs Menu Description Sub menu Description Default Setting Exit Saves and exits the menu Enabled Turns the rule on or off after its YES to enable or NO to disable NO inputs and outputs have been defined Input Toggles through a list of valid Alarm Inputs 1 7 and any additional inputs which NONE inputs set in the Alarm I O Setup were set in the Inputs Setup Menu including Aux gt Inputs Setup M
72. ries AutoDome the motion detection software can be configured to create a Region of Interest within multiple preset positions or scenes It can take advantage of Virtual Masking to ignore motion in predefined areas Motion Detection can also be used as an Alarm Rule input Preset positions 90 through 99 are reserved for programming motion detection scenes NOTICE Motion Detection always takes precedence over AutoTrack object tracking To set up a scene with Motion Detection 1 Choose an unused Preset position from 90 to 99 For this example use Preset scene 95 2 Enter the keyboard command SET 95 ENTER 3 Select YES at the Apply Motion Detection prompt If NO is selected the Preset scene does not activate Motion Detection 4 Select YES at the Apply Region of Interest prompt If NO is selected the entire scene is used for Motion Detection 5 Follow the on screen menu instructions to construct the shape of the screen area you want to detect motion within NOTICE Up to five 5 anchor points can be used to form the area which you want to detect motion within Motion Detection is not activated until the Preset scene is recalled The Motion Detection icon M appears in the upper left hand corner of the display 7 6 Image Stabilization Image Stabilization becomes increasingly important as zoom ranges are extended The advanced image stabilization algorithms of the VG5 Series AutoDome eliminate camera shake for exceptional image clarity Bosch
73. rt of the recalibration for15 minutes to ensure that all manual commands have ceased Manual control is defined as a pan or tilt movement If after the initial 15 minute delay the AutoDome is still under manual control the unit delays the start of recalibration for another 15 minutes It is recommended to set the Inactivity AUX ON 9 to Shot 1 or to Previous AUX so the AutoDome returns to a preset position or starts a tour after the recalibration process is complete The AutoHome recalibration behaves in the following manner under specific circumstances AutoTracker If the AutoDome is actively tracking an object with AutoTracker when the interval elapses or aloss of home is detected the unit will delay recalibration until the AutoTracker stops tracking Preset or Recorded Tour If the AutoDome is performing a preset or playback of a recorded tour when the interval elapses or a loss of home is detected the unit will start the recalibration process immediately If the Inactivity command AUX ON 9 is set to Return to AUX the unit will resume the tour after the recalibration process is complete Using the AutoHome Recalibration Use the following procedure for the initial setup of the AutoHome Recalibration 1 Issue the AUX ON 680 command to check the status of the recalibration settings This command displays a status screen that shows the following information Setting Values Status Enabled Disabled Mode Loss
74. rule the AutoDome preserves the user defined settings and the rule data is restored when the ON 69 ENTER command is issued The OFF 69 ENTER command performs the following actions Disables all alarm rules Displays the message Ack and Reset Alarms if an alarm rule triggered alarm is active when the AutoDome receives the disable command You must acknowledge the alarm before the rule is disabled Prevents the modification of an alarm rule while disabled Alarm Rule Examples Following are three examples for setting up alarm rules The first example is a basic alarm rule and the second and third examples are more complex Example 1 Basic Alarm Rule Scenario We want a door alarm contact to 1 Flash an OSD message ALARM 1 on the display when the alarm is triggered 2 Move the AutoDome camera to a saved position For this example Shot 7 3 Transmit a Bilinx signal over the coax cable to the headend system such as an Allegiant to trigger an alarm response The sequence to program the above alarm rule example is as follows 1 Wire the door contact to Input 1 in the AutoDome This circuit is normally open 2 Define the Alarm Input s From the Inputs Setup menu ensure that Alarm Input 1 is set to N O This is the default setting for Input 1 NOTICE For instruction on wiring alarm and relay connections see the VG5 AutoDome Installation Manual 3 Define the Alarm Outputs from the Outputs Se
75. rval begins its countdown after the offset time Each On increases offset time by 4 hours Each Off decreases offset time by 4 hours Note The offset time does not take effect until the Homing Calibration is enabled On 911 Remote Restart Simulates a power cycle Once issued the AutoDome re homes and displays the start up splash screen Set 900 Edit Tour 1 Standard Enters the Standard Tour Scene menu Shot 900 Edit Tour 2 Custom Enters the Custom Tour Scene menu Set Shot 901 999 Adds Removes a Preposition Shot from Set Adds preset Shot Removes preset Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 64 en AutoDome 600 Series Analog PTZ Camera BLOCK 1 Bosch AD FOANDOARWNE OMANDOARWNHEHE 0 64 pan 2 O amp Table 1 1 Addre Group 1 IN OUT 1 1 OMANDOAKRWBNDY OMAONDORWBHDY Bb 2 o 10 99 Appendix FastAddress Conversions Sample If there is video coming from Camera 131 look at the appropriate conversion table below to convert the FastAddress accordingly i e using an AD system 131 3 and using a Sensormatic system 131 32 Ensure that the camera number displayed within the menu on the keyboard represents the converted camera number BLOCK 2 Bosch AD 65 66 67 68 69 70 71 72 73 74 128 OMANDORWBNE m 2 O A Group 2 IN OUT 100 101 102 103 104 105 106 107 108 109 198 e
76. ry Settings View all menu default settings On Off 50 Playback A continuous Activate Deactivate On Off 51 Playback A single Activate Deactivate On Off 52 Playback B continuous Activate Deactivate On Off 53 Playback B single Activate Deactivate On Off 56 Night Mode Menu On Off Auto Day Night only On Off 57 Night Mode Setting Enables disables Night Mode Day Night only On Off 58 Day Night Threshold On menu Day Night only On Off 59 Night Mode Priority Motion Activates Night Mode before slow shutter preserving full frame integration as light is reduced Color Activates slow shutter before Night Mode preserving color longer as light is reduced On Off 60 On Screen Display On Enable Off Disable F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Keyboard Commands by Number en 41 Locked Function Comm Command Description Key No On 61 Display Adjust Adjust On screen Display On 62 Pre position Title menu Enters Pre position Title menu Refer to Section 3 3 Specifying a Shot or a Sector Title page 27 On 63 Zone Title Menu Enters Zone Title menu Refer to Section 3 3 Specifying a Shot or a Sector Title page 27 On 64 Alarm Status Enters Alarm Status menu Off 65 Alarm Acknowledge Acknowledge alarm or deactivate physical outputs On 66 D
77. s button Enter a value between 3 6 m 12 ft and 30 7 m 100 ft Press Focus Iris again to accept the camera height value Exit the Advanced menu then exit the Main menu OO ON OO BON a Ensuring Smooth AutoTrack Operation Factors such as the viewing angle and unwanted motion from trees for example may interfere with AutoTrack operation Use the following recommendations to ensure smooth AutoTrack operation F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Advanced Features en 49 7 2 2 Mount Mounting Surface Stability Mount the camera in the most stable position Avoid locations affected by vibrations such as those caused by a roof top air conditioner These vibrations may cause complications when the camera zooms in on a target Use the pendant arm mount if possible This mount option provides the most stability for the camera Use guy wires to protect against strong winds if using the parapet mount Field of View Select a location and viewing angle that allows the flow of people to move across the camera s field of view Avoid motion that moves directly towards the camera Avoid locations that attract large numbers of people such as retail stores or intersections Unwanted Motion Use the Virtual Masking feature see Section 7 3 Virtual Masking page 50 to mask unwanted motion from trees or cars Bosch recommends that you dra
78. s the character palette See Section 3 3 Specifying a Shot or a Sector Title page 27 for instructions Clear Scene to delete the selected scene title Restore Defaults Restores the default setting for this menu only F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera On Screen Display Menu Navigation en 17 2 6 Communication Setup Menu The Communication Setup Menu provides access to baud rate and Bilinx control settings Menu items marked with an asterisk are the default settings Communication Setup Exit AutoBaud ON Baud Rate 9600 Bilinx ON Restore Defaults Factory Setting Focus Iris Select Communication Setup Menu Choices Menu Description Sub menu Description Default Setting Exit Saves and exits the menu AutoBaud Turns AutoBaud detection on Toggles ON or OFF ON ON automatically accepts baud rates from 2400 to 57600 Note If stepping from 2400 to 57600 baud you must first set the controller to 19200 for AutoBaud to detect the higher baud rate Baud Rate Manually sets the baud rate when Choices are 2400 4800 9600 19200 38400 and 9600 AutoBaud is set to OFF 57600 Then follow the OSD to confirm the selection Bilinx Turns on Bilinx control communication Toggles ON or OFF ON Only available when not connected to a Bilinx data interface unit
79. s the camera to a preset position and then activates the AutoTrack feature to track an intruder after an alarm is triggered This example uses the Configuration Tool for Imaging Devices CTFID software tool Refer to the Configuration Tool for Imaging Devices User Guide available at www boschsecurity com 1 Launch the CTFID software from a computer that is connected to a VG5 AutoDome Iu Configuration Tool for Imaging Devices Device Information Online Device Type Gen4 Dome Device Model 300 Series 26x Day Night Video Type NTSC Firmware Version 1 08 00 04 MAC Address 00 07 5F 71 CA F8 IP Address 192 168 10 45 Figure 7 1 CTFID Overview Window 2 Click the Online Config button and then expand Alarm j Input Options Input Option 1 Input Option 2 Input Option 3 Input Option 4 Alarm Rule Input Option 5 Input Option 6 Alarm Rule Input Option Input Option 8 Alarm Rule 5 Input Option 9 Input Option 10 Input Option 11 Input Option 12 Output Options ae Opeon Alarm Rul Output Option 2 S t Output Option 3 S Output Option 4 Alarm Rule 9 Output Option 5 Output Option 6 Alarm Rule Output Option 7 Output Option 8 Alarm Rule Output Option 9 Output Option 10 larm Rule CE s en4 Dome OutputOption Data 6 is downloaded Gen4 Dome OutputOption Data 6 is uploaded Gen4 Dome OutputOption Data 6 is downloaded Gen4 Dome OutputOption Data 6 is uploaded Figure 7 2 Expanded Alarm Group 3
80. stAddress unaddressed domes Display and program unaddressed AutoDomes Set 1 99 Pre position Programming Set Programs a preset view Shot 1 99 Pre position Recall Shot Recall programmed preset Set 100 Pre position Menu Enters the Pre position menu Set Shot 101 Autopan Left Limit Set Programs left limit Shot Shows limit Set Shot 102 Autopan Right Limit Set Programs right limit Shot Shows limit Set 110 Factory P T Home Position Set Recalibrate home position On Off 680 Homing Recalibration Display Displays the current mode of operation intervals time until the next calibration and the number of recalibrations that have occurred On Turns display on Off Turns off the display On Off 681 Homing Recalibration On Enables recalibration This action does not cause the dome to re home immediately Off Disables recalibration On 682 Recalibration Mode Each On command toggles the recalibration mode as follows Recalibrates only on the loss of home position Recalibrates on the loss of home and for every periodic interval On Off 683 Recalibration Interval Changes the homing recalibration interval Intervals are in 6 hour increments up to 72 hours Each On increases interval by 6 hours Each Off decreases interval by 6 hours On Off 684 Initial Offset Time Sets the initial offset time for the recalibration interval The offset time starts after the Homing Calibration is enabled The recalibration inte
81. t 3 6 m 12 ft Virtual Masking Enters the Virtual Mask menu See Section 7 3 Virtual Masking page 50 Allows up to 24 virtual masks using five anchor points Restore Defaults Restores the default settings for this menu 2 11 Diagnostics Menu The Diagnostics menu provides access to a list of diagnostic tools and events Diagnostics Exit Alarm Status BIST Internal Temp Deg F Deg C High Temp Events Deg F Deg C Highest Temp Deg F Deg C Low Temp Events Deg F Deg C Lowest Temp Deg F Deg C Security Access 0 CTFID Access 0 Homing Events 0 Homing Failed 0 Loss Home Events 0 Home Position Good YES Restart Events Low Volt Events 0 Power Up Events 0 Video Loss Events 0 Total Time On Ohr Omin Focus Iris Save and Exit Diagnostic Events Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 24 en On Screen Display Menu Navigation AutoDome 600 Series Analog PTZ Camera Menu Description Sub menu Description Exit Saves and exits the menu Alarm Status Enters the Alarm Status menu and displays the real time status of alarm inputs and outputs Alarm Inputs 1 to 7 Alarm Outputs 1 to 3 and Alarm Relay BIST Enters the Perform Built in Self Tests menu If confirmed the BIST tests start and the results are displayed YES to start test NO to exit the menu Typ
82. tandard or custom keyboard ON 1 99 command Aux Off Responds to a standard or custom keyboard OFF 1 99 command Shot Responds to a Preset shot or scene from 1 99 AutoTrack Triggers an alarm when set to ON Motion Detection Triggers an alarm when set to ON NOTICE Alarm inputs 1 and 2 provide tamper detection if programmed as supervised for breaks or shorts in an alarm circuit See the VG5 AutoDome Installation Manual for wiring instructions F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera On Screen Display Menu Navigation en 19 Outputs Setup Menu Outputs Setup Exit Alarm Output 1 Alarm Output 2 Alarm Output 3 Alarm Relay NONE Aux On Aux Off Shot 9 OSD 10 Transmit 11 NONE 12 NONE ANOOaRWBNE Focus Iris Select Type Right Left Select Mode N O 140 N O Physical N O Outputs N O 1 5 12 8 Command 99 Outputs Outputs Setup Menu Choices Menu Description Sub menu Description Default Setting Exit Saves and exits the menu Outputs Setup Defines physical outputs and keyboard commands for use in a rule Outputs 1 3 Defines a physical N O Normally open circuit N O output N C Normally closed circuit Alarm Relay A fixed output available for use in a rule Outputs 5 12 Defines a command Aux O
83. tive Auto Iris Level Reduces the camera s iris Sliding scale 8 level for proper exposure 1 to 15 Focus Speed Adjusts the manual focus Sliding scale 2 speed 1to 8 Iris Speed Adjusts the manual iris speed Sliding scale 5 1 to 10 Max Zoom Speed Adjusts the manual zoom SLOW MEDIUM or FAST FAST speed Digital Zoom Enables digital zoom OFF or ON ON Restore Defaults Restores all default settings for this menu 2 4 PTZ Setup Menu The PTZ Menu provides access to pan tilt zoom settings that can be changed or customized Menu items marked with an asterisk are the default settings PTZ Setup Exit Autopan Tour 1 Period Tour 2 Period PTZ Fixed Speed Inactivity Inact Period AutoPivot AutoDome Orientation Tilt Up Limit Restore Defaults Factory Setting Freeze Frame on Preposition ON Focus Iris Select 30 deg sec 5 sec 5 sec 4 OFF 2 min ON NORMAL PTZ Menu Choices Bosch Security Systems Inc User Manual F 01U 270 005 2 0 2012 06 14 en On Screen Display Menu Navigation AutoDome 600 Series Analog PTZ Camera Menu Description Sub menu Description Default Setting Exit Exits the menu AutoPan Adjusts speed of camera during Sliding scale 30 sec AutoPan and AutoScan 1 sec to 60 sec Tour 1 Period Changes dwell time between Sliding
84. tup menu a Ensure Output 5 is set to OSD This is the default setting for Output 5 b Set Output 6 to Shot 7 c Set Output 7 to Transmit a Bilinx signal to the head end F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Advanced Features en 45 4 Set up the Alarm Rule for this example use Rule 1 Select the Inputs from the Rule Setup menu a Select Rule 1 b Set the first input to Alarm Input 1 5 Select the outputs a Set the first output to OSD b Set the second output to Shot 7 c Set the third output to Transmit 6 Enable the rule Highlight Enabled and select YES Example 2 Advanced Alarm Rule Scenario A VG5 AutoDome located at an airport is set to AutoPan Between Limits from the parking garage to the airport terminal The gate entering the airport has an alarm contact connected to the AutoDome and the perimeter fence in the area of the gate has an infrared IR motion detection sensor connected to the AutoDome When both the gate contact and motion detector alarms are activated at the same time we want the alarm rule to 1 Flash an OSD message ALARM 2 on the monitor 2 Stop the AutoPan and move the camera to a saved position Shot 5 viewing the fence 3 Turn on AutoTrack 4 Transmit a Bilinx signal to the head end system to trigger an alarm response The sequence to program this alarm rule example is as follows 1 Wire and set the
85. ty Systems Inc User Manual F 01U 270 005 2 0 2012 06 42 en Keyboard Commands by Number AutoDome 600 Series Analog PTZ Camera Locked Function Comm Command Description Key No On Off 95 Display Azimuth Elevation On Displays azimuth elevation readings Readings Off Hides azimuth elevation readings Refer to Section 7 8 Azimuth Elevation and Compass Directions page 52 On Off 96 Display Compass Readings On Displays compass heading Off Hides compass heading Refer to Section 7 8 Azimuth Elevation and Compass Directions page 52 On 99 Factory P T Home Position Recalibrates home position can be used as an Alarm Output On Off 100 Record A Activate Deactivate On Off 101 Record B Activate Deactivate On 997 FastAddress display Display current address On 998 FastAddress all units Display and program current address On 999 FastAddress unaddressed domes Display and program unaddressed AutoDomes Set 1 99 Pre position Programming Set Programs a preset view Shot 1 99 Pre position Recall Shot Recall programmed preset Set 100 Pre position Menu Enters the Pre position menu Set Shot 101 Autopan Left Limit Set Programs left limit Shot Shows limit Set Shot 102 Autopan Right Limit Set Programs right limit Shot Shows limit Set 110 Factory P T Home Position Set Recalibrate home position On Off 680 Homing Recalibrati
86. udio output card and speakers Play a secondary source of audio on the computer If you still do not hear audio replace the speakers and try again If O K then Ensure that the Audio option is enabled for the IP device a b oe Access the Settings Web page for the IP enabled device Expand the Encoder Settings link then click Audio Settings Ensure that On is selected from the Enable Audio drop down list Then click Set If O K then Check the microphone Connect appropriate speakers directly to the microphone at the camera site and confirm that the audio is clear and audible at the location An audio problem or noise at the source will further degrade as it travels through all the cables and connections If O K then Verify the cable type and installation used for audio connections between the microphone and the VG5 AutoDome Cable type Coaxial Cable length 10 m 33 ft maximum Refer to the VG5 AutoDome Installation Manual for more information F 01U 270 005 2 0 2012 06 User Manual Bosch Security Systems Inc AutoDome 600 Series Analog PTZ Camera Troubleshooting Guide en 61 Problem Solution If O K then Check all network connections If the video is clear and contains no distortion then the network connections are probably not the source of audio problems Ensure that the maximum distance between any two Ethernet connections is 100 m 328
87. uts with the following convention 1 a Command Number and 2 a Function key input The AutoDome uses the PRESET command key to save and recall presets pre positions 1 through 99 NOTICE To save a preset enter the desired number and hold the PRESET key for approximately two 2 seconds To recall a preset enter the desired preset number or command and momentarily press and release the PRESET key 4 2 3 Pelco Keyboard Commands Keyboard Command User Action Description 0 Pattern Press Initiates recording continuous playback based upon current Recording setting A or B in the Setup Menu Press and hold Initiates recording based upon current Recording setting A or B in the Setup Menu Press ACK to end recording 1 Pattern Press Initiate Recording A continuous playback Press and hold Initiate Recording A Press ACK to end recording 2 Pattern Press Initiate Recording B continuous playback Press and hold Initiate Recording B Press ACK to end recording 3 Pattern Press Initiate the AutoDome standard preset tour Tour 1 4 Pattern Press Initiate the AutoDome custom preset tour Tour 2 1 Aux On Aux Off Press Activates deactivates alarm output 1 2 Aux On Aux Off Press Activates deactivates alarm output 2 3 Aux On Aux Off Press Activates deactivates alarm output 3 4 Aux On Aux Off Press Activates deactivates alarm relay 91 Aux On Pr
88. w the virtual mask 10 larger than the object to be masked Avoid neon lights flashing lights night time lights and reflected light from a window or mirror for example The flickering of these lights can affect the AutoTrack operation Use a Virtual Mask to hide these type of lights if they cannot be avoided Check the virtual mask periodically to ensure that it still covers the entire object to be masked Adjust the mask if necessary AutoTrack Optimization The AutoDome achieves optimum tracking performance when the focal length of the lens during AutoPan is as close to the focal length of the lens during an AutoTrack operation The ambient light conditions also affect the AutoTrack performance Dynamic Light Conditions The ambient lighting conditions affect AutoTrack performance especially in outdoor dynamic lighting conditions that change daily or hourly To optimize the AutoTrack performance under changing light conditions Bosch recommends that you configure the AutoTrack Sensitivity and the AutoPan speeds Bosch recommends setting the AutoTrack Sensitivity to Auto and suggests the following AutoPan speed for outdoor conditions Camera Focal Length Maximum Suggested AutoPan Speed degrees sec Near field Wide Angle 5 Mid field 2 Far field Telephoto 1 If you need a higher AutoPan speed set the AutoTrack Sensitivity to a value between 1 and 10 in the Advanced Feature Setup menu Bosch S
Download Pdf Manuals
Related Search
Related Contents
Philips TT2020 Acer N300 Series User's Manual Using - Burco Sun Fire V210 and V240 Servers Getting Started Guide - it 708KB - JICA Ferno® Tactical Litter Nilfisk-ALTO 580 P User's Manual Manual de Utilização e-RH para Servidor em Geral (Módulo Yamaha XVS250 Motorcycle User Manual Copyright © All rights reserved.