Home
Bosch Appliances Security Camera LTC 9385 User's Manual
Contents
1. For units intended to operate with 230VAC 50Hz the input and output power cord must comply with the latest versions of IEC Publication 227 or IEC Publication 245 Power supply cords should be routed so they are not likely to be walked on or pinched Pay particular attention to location of cords and plugs convenience receptacles and the point of exit from the appliance Overloading Do not overload outlets and extension cords this can result in a risk of fire or electrical shock For Outdoor Product Power Lines An outdoor system should not be located in the vicinity of overhead power lines electric lights or power circuits or where it may contact such power lines or circuits When installing an outdoor system extreme care should be taken to keep from touching power lines or circuits as this contact might be fatal U S A models only refer to the National Electrical Code Article 820 regarding installation of CATV systems For Rack mount Product L Ventilation This unit should not be placed in a built in installation or rack unless proper ventilation is provided or the manufacturer s instructions have been adhered to The equipment must not exceed its maximum operating temperature requirements Mechanical Loading Mounting of the equipment in a rack shall be such that a hazardous condition is not achieved due to uneven mechanical loading Bosch Security Systems January 26 2005 CAUTIO
2. tight seal Not doing so could damage the camera the housing or both 5 8 2 Camera Power Connections LTC 9385 60 Housings These housings are to be connected to 115VAC and are designed for use where site power is 115volts The LTC 9385 60 housings should only be used with 115volt cameras The integral heater defogger requires 115volts The housing is shipped with the heater defogger connected to the terminal block Installing a 115 volt camera into the LTC 9385 60 housing simply requires the camera s line cord to be plugged into the NEMA 5 15R receptacle provided See FIGURE 10 LTC 9385 Series Instruction Manual Installation LTC 9385 20 Housings These housings are to be connected to 24VAC and are designed for use where site power is 24volts The LTC 9385 20 housings should only be used with 24volt cameras The integral heater defogger requires 24volts The housing is shipped with the heater defogger connected to the terminal block Installing a 24 volt camera into the LTC 9385 20 housing simply requires the two flying leads be attached to the camera s terminal block See FIGURE 10 LTC 9385 50 Housings These housings are to be connected to 230VAC and are designed for use where site power is 230volts The LTC 9385 50 housings should only be used with 230volt cameras The integral heater defogger requires 230volts The housing is shipped with the heater defogger connected to the terminal block Installing a 2
3. 0 31lin of insulation away from the wires making sure not to nick the wires 3 A screw terminal lug is provided for securing a safety ground To attach the safety grounding wire of the power cord green 115volt green yellow 230volt first unscrew the terminal lug and strip and crimp the grounding wire into the lug Next reattach the terminal lug to the rail assembly using the M4 x 10 screw and lock washer provided See FIGURE 8 Ground Wire Power Cable sk IE mmm bitte Terminal Lug FIGURE 8 Securing the Ground Wire Bosch Security Systems January 26 2005 4 Connect both the line and neutral wires of the power cord to the terminal block Make sure the line and neutral wires are connected to the correct positions on the terminal block that are across from the appropriate colored wire See FIGURE 9 Power Cable Line amp Neutral Wires 1 Zomme Wi IHI HF SEN i P Terminal Block FIGURE 9 Attaching Line and Neutral Wires 5 Pull any excess cord through the liquid tight fitting and tighten the flex fitting to 8 5N m to 9 0N m 75in lb to 80in lb This torque rating is approximately 1 to 1 1 2 turns past the point that the fitting starts to grip the cord Failure to do so will result in water damage to all electronic parts Use a tie wrap included to provide strain relief on the power cord at the exit point inside the unit Securely tighten all fittings to ensure a liquid
4. ABRIR CUIDADO PARA REDUZIR O RISCO DE CHOQUE ELECTRICO NAO RETIRE A TAMPA OU A PARTE POSTERIOR NO INTERIOR NAO EXISTEM PECAS QUE POSSAM SER REPARADAS PELO UTILIZADOR REMETA A ASSISTENCIA PARA OS TECNICOS QUALIFICADOS Este s mbolo indica a presen a de tens o perigosa n o isolada dentro da estrutura do produto o que pode constituir risco de choque el ctrico O utilizador deve consultar as instru es de funcionamento e manuten o assist ncia nos documentos que acompanham o aparelho Aten o a instala o deve ser executada apenas por t cnicos qualificados da assist ncia de acordo com o c digo el ctrico nacional ou os c digos locais aplic veis Corte de corrente As unidades com ou sem interruptores ON OFF ligar desligar recebem corrente sempre que o fio de alimenta o est introduzido na fonte de alimenta o contudo a unidade apenas est operacional quando o interruptor ON OFF est na posi o ON O fio de alimenta o destina se a desligar a Sicurezza ATTENZIONE PERICOLO DI SCOSSA ELETTRICA NON APRIRE ATTENZIONE PER RIDURRE IL RISCHIO DI SCOSSE ELETTRICHE NON RIMUOVERE LA COPERTURA O IL PANNELLO POSTERIORE L UNIT NON CONTIENE COMPONENTI INTERNI RIPARABILI DALL UTENTE PER QUALSIASI INTERVENTO RIVOLGERSI A PERSONALE TECNICO QUALIFICATO Questo simbolo indica la presenza di tensione pericolosa non isolata all interno del contenitore del prodotto Ci com
5. seal from the hardware kit Part Number 315 2569 001 An extra pull seal is also provided See FIGURE 15 HEAD Long End FIGURE 15 Pull Seal Bosch Security Systems January 26 2005 3 Insert the long end of the pull seal into the breather hole starting from the front side of the face plate See FIGURE 16 Housing Face Plate Pull Seal FIGURE 16 Inserting the Pull Seal 4 Reach into the housing and grip the pull seal s long end from the back of the front face plate Steadily pull the long end until the head of the pull seal is flat against the front of the end cap See FIGURE 17 NOTE The Pull Seal s long end will stretch when pulled through the breather hole Housing cut away Grip and Pull FIGURE 17 Installing the Pull Seal LTC 9385 Series Instruction Manual Installation 5 13 2 Housing Assembly 3 Align the cover holes with the base assembly 1 The lens support screw is provided to support holes and replace the two M4 screws and the rail assembly Adjustment will only be washers This secures the cover onto the rest of necessary if the rail assembly is rotated at angle the housing other than horizontal If the screw head is not touching the cover when the cover is installed NOTE Make sure the breather hole is located at the loosen the screw until it does See FIGURE 18 bottom of the housing If it is not remove both front retaining rings and the face plate Orient them so the br
6. 30 volt camera into the LTC 9385 50 housing simply requires the camera s line cord to be plugged into the Schuko inline receptacle provided See FIGURE 10 115 VAC 1 Nema 5 15R Receptacle tp n 230 VAC 4 Schuko Inline Socket Receptacle 24 VAC 2 Flying Leads FIGURE 10 Camera Connections Bosch Security Systems January 26 2005 5 9 Video Coax Connection WARNING Only use the cables specified under INSTALLATION Cable Requirements for wiring of the video coax connection If lens control or feed through wires will be used L Install the long flexible portion of the small liquid tight fitting on the video coax cable and pull the cable through the small fitting on the rear end of the base assembly The fitting will accept cables with diameters from 4 6mm 0 181lin to 79mm 0 312in See FIGURE 11 2 Attach a BNC connector to the coax and connect it to the camera Pull any excess cable through the liquid tight fitting and tighten the flex fitting to 4 0N m to 4 5N m 35in Ib to 40in Ib This torque rating is approximately 1 to 1 1 2 turns past the point that the fitting starts to grip the cable Failure to do so will result in water damage to all electronic parts Use a tie wrap included to provide strain relief on the video cable at the exit point inside the unit Be sure to securely tighten all fittings to ensure a liquid tight seal Not doing so could damage the camera the housing or bot
7. ESDE cee ese ntt ah E So INSIALLATION EE Z 5 1 Mode Desa erre eae a tan ee sees Ope eee STO EE Preteens ek 7 Oe Took RME aay nnn eee oh ae eee ee Gee Ga Gee oy EG AGO SO Ee 8 De lore E ose ane cae Epa o Ge E Gace wae eter ete Geen ence EE 8 Oe Cable Requiem se sra sara eter ues coos PENA SEI PISO REC To tse setae ets A 8 oo Disaccemiol and NOUD soia dee menne teh wee Ban A a A A 8 56 C mera lens ET e ween tebe ncen Gua rapa is RR ade deuceee ne be mts 9 Oy Camer Lens Wy eet Seege e e eee ee et de A e eee Oona e our eb RS a 10 Do Ee SON penas gece DEE ee DRE eeh 10 59 Video Coax Connection dios dr da bbw dd dad dw ee 2 OSes whe eS SE et Rew ees 12 OO ds WANS hcg cepa Arden e O A SG ea de 13 Dail Camera Lens EIER e E eo en podes Dos ESTAS DO GEC REPRISE DEAN GERE E 13 gda Cama Lens sine arise E beenie E ore SoS EE 13 Ola Pal Assem eon sen hoor porns pees IPA EE SOR UT ERR ara 14 60 EAPLODED VIEW ata deco 240d esha dba ated dra dia Se uge bad beds Sra ea HE 16 7 0 PARIS MNO erer e r EEE E a a ee bee be ee eee ig a a SOS 16 Bosch Security Systems January 26 2005 LTC 9385 Series Instruction Manual Unpacking 1 0 UNPACKING This electronic equipment should be unpacked and handled carefully Check for the following items Quantity Part Description 1 1 4 20 x 3 8in BHCS Button Head Cap Screw 1 4 20 x 1 2in BHCS 1 4 20 x 5 8in BHCS 1 4 20 x 3 4in BHCS 1 4 20 x 7 8in BHCS 3 2mm 0 125in plastic spa
8. LTC 9385 Series Security Systems Instruction Manual EN Outdoor Housings LTC 9385 Series Instruction Manual Important Safeguards Important Safeguards l Read Follow and Retain Instructions All safety 10 and operating instructions should be read and followed before operating the unit Retain instructions for future reference Heed Warnings Adhere to all warnings on the unit and in the operating instructions Attachments Attachments not recommended by the product manufacturer should not be used as they may cause hazards Installation Cautions Do not place this unit on an unstable stand tripod bracket or mount The unit may fall causing serious injury to a person and serious damage to the unit Use only manufacturer recommended accessories or those sold with the product Mount the unit per the manufacturer s instructions Appliance and cart combination should be moved with care Quick stops excessive force or uneven surfaces may cause the appliance and cart combination to overturn Cleaning Unplug the unit from the outlet before cleaning Follow any instructions provided with the unit Generally using a damp cloth for cleaning is 11 sufficient Do not use liquid cleaners or aerosol cleaners Servicing Do not attempt to service this unit yourself Opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualifie
9. N RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL This symbol indicates the presence of uninsulated dangerous voltage within the product s enclosure This may constitute a risk of electric shock The user should consult the operating and maintenance servicing instructions in the literature accompanying the appliance Attention Installation should be performed by qualified service personnel only in accordance with the National Electrical Code or applicable local codes Power Disconnect Units with or without ON OFF switches have power supplied to the unit whenever the power cord is inserted into the power source however the unit is operational only when the ON OFF switch is in the ON position The power cord is the main power disconnect for all units LTC 9385 Series Instruction Manual Safety Precautions Sicherheitshinweise VORSICHT ELEKTRISCHE SPANNUNG NICHT OFFNEN VORSICHT UM EINEN ELEKTRISCHEN SCHLAG ZU VERMEIDEN IST DIE ABDECKUNG ODER R CKSEITE NICHT ZU ENTFERNEN ES BEFINDEN SICH KEINE TEILE IN DIESEM BEREICH DIE VOM BENUTZER GEWARTET WERDEN K NNEN LASSEN SIE WARTUNGSARBEITEN NUR VON QUALIFIZIERTEM WARTUNGSPERSONAL AUSF HREN Das Symbol macht auf nicht isolierte gef hrliche Spannung im Geh use aufmerksam Dies kann zu einem el
10. URE 7 3 8in NPT N FIGURE 7 3 8in NPT Plug Insertion 5 8 1 Supply Power Connections The LTC 9385 Series housings offer the user one of three voltage configurations The suffix to the housing model number will determine the supply voltage required Any camera installed in the LTC 9385 Series housings must be of the same voltage type as the housing The integral heater defogger also requires the same voltage as the housing These housings do not contain step down or isolation transformers See the Model Designation chart for suffixes and supply voltages required Power connection into the housings is to be supplied through a minimum type UL Standard Af cord acceptable for outdoor use Installation must conform to applicable NEC and local codes Use the Recommended Maximum Cable Lengths chart below for proper wire size selection LTC 9385 Series Instruction Manual Installation Recommended Maximum Cable Lengths Models Wire Size Distance mm AWG meters feet 1 115 VAC 1 5 16 1000 3280 2 5 14 1600 5250 4 12 2500 8200 2 24 VAC 0 5 22 10 30 0 5 20 15 50 1 18 25 80 1 5 16 40 120 2 5 14 70 210 4 230 VAC 1 5 16 4000 13000 2 5 14 6400 21000 4 12 10000 32800 L Use the liquid tight fitting on the left of the housing to route the power supply cord into the housing 2 Allow enough cord for connection to the terminal block approximately 130mm 5in Strip no less than 6mm 0 24in and no more than 8mm
11. and connect it to the lens If mating connector is not available connect directly to the lens cable Pull any excess cable through the liquid tight fitting and tighten the flex fitting to 8 5N m to 9 0N m 75in Ib to 80in Ib This torque rating is approximately 1 to 1 1 2 turns past finger tight depending on the size of the wire Failure to do so will result in water damage to all electronic parts Use a tie wrap included to provide strain relief on the lens control cable at the exit point inside the unit See FIGURE 12 NOTE See specification on the lens cord for correct plug connection Be sure to securely tighten all fittings to ensure a liquid tight seal Not doing so could damage the camera the housing or both iCCD Camera Lens Control Connectors CCD Camera l FIGURE 12 Lens Control Cable Wiring Bosch Security Systems January 26 2005 If using a pan tilt with a feed through cable insert the camera lens function cable in through the right fitting at the rear of the cradle Wire the functions as described above or as needed 5 11 Camera Lens Orientation A unique feature of the LTC 9385 Series housing is the ability to rotate the mounting base 360 around the rail assembly Simply loosen the three M4 screws with a M3 hex wrench Rotate the base assembly around the rail assembly to any position and tighten the M4 screws It is preferable to keep the rail assembly under the camera not over i
12. cer 0 4mm 0 016in plastic spacer Nylon bushings 3 8in NPT plug Small flex fitting Pull Seals Large flex fitting Cable ties Won Ne e NA WS ra ra Fa Fa If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper If any items are missing notify your Bosch Security Systems Inc Sales Representative or Customer Service The shipping carton is the safest container in which the unit may be transported Save it for possible future use 2 0 SERVICE If the unit ever needs repair service the customer should contact the nearest Bosch Security Systems Inc Service Center for return authorization and shipping instructions Service Centers USA Phone 800 366 2283 or 717 735 6638 fax 800 366 1329 or 717 735 6639 CCTV Spare Parts Phone 800 894 5215 or 408 956 3853 or 3854 fax 408 957 3198 e mail BoschCCTVparts ca slr com Canada Phone 514 738 2434 Europe Middle East amp Asia Pacific Region Phone 32 1 440 0711 For additional information see www boschsecurity com Bosch Security Systems January 26 2005 3 0 CARE AND MAINTENANCE There are no moving parts in this unit Regularly scheduled maintenance will help prolong the operational life of this unit Clean the viewing window as needed with a mild nonabrasive detergent in water and a soft cloth 4 0 DESCRIPTION The LTC 9385 Series of environmental housings are attractive aluminum enclosures design
13. d service personnel Damage Requiring Service Unplug the unit from the main AC power source and refer servicing to qualified service personnel under the following conditions 12 e When the power supply cord or plug is damaged If liquid has been spilled or an object has fallen into the unit If the unit has been exposed to water and or inclement weather rain snow etc If the unit does not operate normally when following the operating instructions Adjust only those controls specified in the operating instructions Improper adjustment of other controls may result in damage and require extensive work by a qualified technician to restore the unit to normal operation If the unit has been dropped or the cabinet damaged If the unit exhibits a distinct change in performance this indicates that service is needed 13 Replacement Parts When replacement parts are required the service technician should use replacement parts specified by the manufacturer or that have the same characteristics as the original part Unauthorized substitutions may result in fire electrical shock or other hazards Safety Check Upon completion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition Bosch Security Systems January 26 2005 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of pow
14. de screwdriver ble Type HO5RN F3GO 75 and e Phillips head screwdriver HOSRN F3G1 00 e M7 7mm hex wrench or socket Cable Size Outside diameter between 4 3mm e M3 3mm hex wrench and 11 9mm 0 170in and 0 470in e M4 4mm or 5 32in hex wrench Cable Shape Round E dh djus aheri 2 conductor version s r A Rati VDE e Wire cutter stripper cr mper tool Agency Rating MOE 5 3 Hardware Required Sources Olflex 1600252 f Olflex 1600253 e M6 screws X3 or 1 4in screws X3 e Mp nuts X3 or 1 4in nuts X3 TE Ecs We TE e Mp lock h X3 ock washers X3 or Cable Type Jacketed Multiconductor Cable 1 4in lock washers X3 Cable Size Outside diameter between 4 3mm and 11 9mm 0 170in and 0 470in 5 4 Cable Requirements i Overall shielding Conductors Stranded 20 to 16 AWG wire Conductor Insulation Color coded Sources Belden 9552 Belden 9554 Video Transmission Coaxial Cable Type RG 59 U Runs lt 1000ft RG 11 U Runs lt 2000ft Cable Size Outside diameter between 4 6mm and 7 9mm 0 181in and 0 312in Shield gt 93 Braided Copper Shield DC Resistance gt 159 1000ft RG 59 U 5 5 Disassembly and Mounting gt 60 1000ft RG 11 U 1 Detach the hardware kit from the housing 2 Use a M7 hex wrench or socket to remove the E E two M4 screws from the housing cover Save all hardware which will be needed in reassembly T t Rati gt 80 C 176 F ve em Sources Belden 9259 Belden 9238 Input Power Cord Nort
15. eather hole is located at the bottom and the gaps in the retaining rings are centered over the breather hole See FIGURE 20 Lens Support Screw FIGURE 18 Support Screw Adjustment 2 Replace the cover onto the base assembly by grasping the cover and gently pushing it over the Breather Pole eomered end cap and o ring Make sure the o ring is not pinched The safety cable can be routed between FIGURE 20 Location of the Breather Hole the cover and the base See FIGURE 19 Base Assembly End Cap FIGURE 19 Replacing the Cover Bosch Security Systems January 26 2005 LTC 9385 Series Instruction Manual Exploded View 6 0 EXPLODED VIEW GH an Ge r ao Af Part Description 115VAC Heater Bracket Assembly M3 x 20 Screw Rivet 5 32in x 0 415in 24VAC Heater Bracket Assembly M3 x 20 Screw PSB R ot 4 sg Se LI ag Pe an A E a be FIGURE 21 abra Gi Ref Drawing Ref Drawing No No Oty Part Description No No Oty Mounting Base Assembly Kit 315 2805 001 115VAC Heater Bracket Assembly Kit 315 2809 001 1 1 Mounting Base Assembly 9 1 2 1 Wire Grip Cap 1 3 315 2298 900 1 EP O ring 037 2 5 315 2327 900 2 EP O ring 248 17 7 M4 Internal Star Lock Washer 24VAC Heater Bracket Assembly Kit 315 2810 001 21 3 M4 Hex Head Cap Screw 9 1 22 3 M4 Fender Washer se 1 2 115VAC Rail Assembly Kit 315 2806 001 Rivet 5 32in x 0 415in 230VAC Heater Bracke
16. ed for outdoor CCD camera installations 4 1 Enclosure Rating 41 1 NEMA 3R and IP54 The LTC 9385 Series housings include a breather hole in the front face plate The breather hole prevents the accumulation of moisture inside the housing when installed in areas of high humidity With the breather hole open the LIC 9385 Series housings meet the enclosure rating requirements of NEMA 3R and IP54 4 1 2 NEMA 4 and IP65 For installations requiring an enclosure rating of NEMA 4 or IP65 the breather hole must be plugged using the pull seal Part No 315 2569 001 provided in the hardware kit Refer to Final Assembly under INSTALLATION for proper installation 5 0 INSTALLATION This installation should be made by a qualified service person and conform to all local codes 5 1 Model Designation Model Rated Range Power No Input Consumption LTC 9385 60 115VAC 50 60Hz 108 to 132 50W LTC 9385 20 24VAC 50 60Hz 21 6 to 26 4 50W LTC 9385 50 230VAC 50 60Hz 207 to 253 50W Heater requires 40 watts Do Not Exceed 30VAC Input on 24VAC models Operation above 30VAC violates low voltage operation Class 2 Specifications Normal operation is 24VAC Maximum Camera Lens Size Accepts cameras up to 102W x 71H mm 4 0 x 2 8in lenses up to 102W x 92H mm 4 0 x 3 6in and camera lens combinations up to 345L mm 13 6in LTC 9385 Series Instruction Manual Installation 5 2 Tools Required Input Power Cord European e Flat bla
17. ektrischen Schlag f hren Der Benutzer sollte sich ausf hrlich ber Anweisungen f r die Bedienung und Instandhaltung Wartung in den begleitenden Unterlagen informieren Achtung Die Installation sollte nur von qualifiziertem Kundendienstpersonal gem jeweils zutreffender Elektrovorschriften ausgef hrt werden Unterbrechung des Netzanschlusses Ger te mit oder ohne Netzschalter haben Spannung am Ger t anliegen sobald der Netzstecker in die Steckdose gesteckt wird Das Ger t ist jedoch nur betriebsbereit wenn der Netzschalter EIN AUS auf EIN steht Wenn das Netzkabel aus der Steckdose gezogen wird ist die Spannungszuf hrung zum Ger t vollkommen unterbrochen Precauciones de Seguridad ATTENZIONE NON APRIRE PRECAUCI N PARA DISMINUIR EL RIESGO DE DESCARGA EL CTRICA NO RETIRE LA CUBIERTA NI LA PARTE POSTERIOR NO EXISTEN PIEZAS DE RECAMBIO EN EL INTERIOR DEL EQUIPO EL PERSONAL DE SERVICIO CUALIFICADO SE ENCARGA DE REALIZAR LAS REPARACIONES Este s mbolo indica que existen puntos de tensi n peligrosos sin aislamiento dentro de la cubierta de la unidad Estos puntos pueden constituir un riesgo de descarga el ctrica El usuario debe consultar las instrucciones de funcionamiento y mantenimiento reparaci n en la documentaci n que se suministra con el aparato Atenci n la instalaci n la debe realizar nicamente personal cualificado de conformidad con el National Electric Code o las normas aplicab
18. er supply to use contact your dealer or local power company For units intended to operate from battery power refer to the operating instructions For units intended to operate with External Power Supplies use only the recommended approved power supplies For units intended to operate with a limited power source this power source must comply with EN60950 Substitutions may damage the unit or cause fire or shock For units intended to operate at 24VAC normal input voltage is 24VAC Voltage applied to the units power input should not exceed 30VAC User supplied wiring from the 24VAC supply to unit must be in compliance with electrical codes Class 2 power levels Do not ground the 24VAC supply at the terminals or at the unit s power supply terminals Coax Grounding If an outside cable system is connected to the unit ensure that the cable system is grounded U S A models only Section 810 of the National Electrical Code ANSI NFPA No 70 provides information regarding proper grounding of the mount and supporting structure grounding of the coax to a discharge unit size of grounding conductors location of discharge unit connection to grounding electrodes and requirements for the grounding electrode Grounding or Polarization This unit may be equipped with a polarized alternating current line plug a plug with one blade wider than the other This safety feature allows the plug to fit into the power outlet
19. h If no lens control or feed through wires will be used L Install the long flexible portion of a large liquid tight fitting on the video coax cable and pull the cable through the large right fitting on the rear end of the base assembly Refer to FIGURES 11 and 12 2 Attach a BNC connector to the coax and connect it to the camera Pull any excess cable through the liquid tight fitting and tighten the flex fitting to 8 5N m to 9 0N m 75in Ib to 80in lb This torque rating is approximately 1 to 1 1 2 turns past the point that the fitting starts to grip the wire Failure to do so will result in water damage to all electronic parts Use a tie wrap included to provide strain relief on the video cable at the exit point inside the unit Be sure to securely tighten all fittings to ensure a liquid tight seal Not doing so could damage the camera the housing or both LTC 9385 Series Instruction Manual Installation BNC Connector Video Coax Cable CCD Camera nn Small Fitting Video Coax Cable CCD Camera BNC Connector Small Fitting FIGURE 11 Video Coax Connection 510 Lens Wiring WARNING Only use the cables specified under INSTALLATION Cable Requirements for wiring of the lens If installing a zoom lens insert the lens control cable with installed flexible fitting in through the fitting on the right rear of the base assembly Attach the lens wiring to the lens mating connector
20. h American Cable Type SJTOW A Rated Cable Size Outside diameter between 4 3mm and 11 9mm 0 170in and 0 470in Conductors 3 conductor version and 2 conductor version Agency Rating UL C S A UL VW 1 Temperature Rating 105 C V M4 Screws Voltage Rating 300 V Sources Belden 19506 FIGURE 1 Removing the M4 Cover Screws Belden 19509 Northwire 573939 Bosch Security Systems January 26 2005 LTC 9385 Series Instruction Manual Installation 3 Remove the cover from the base assembly by grasping the cover and gently pulling forward Do not remove the safety cable from the cover or the base assembly See FIGURE 2 Base Assembly FIGURE 2 Removing the Cover 4 Attach the housing to an appropriate mount or pan tilt Use the instructions provided with the mount or pan tilt The base assembly has three clearance holes for mounting Use three M6 screws and nuts or three 1 4in screws and nuts not provided Lock washers are required not provided Rotating the rail assembly will allow access to the mounting holes This can be accomplished by loosening the three M4 screws See also Camera Lens Orientation It will be easier to mount the base before installing the camera but it may be mounted anytime during the installation process See FIGURE 3 Rail Assembly M4 Screws Mounting Holes FIGURE 3 Mounting the Base Assembly Bosch Security Systems January 26 2005 5 6 Camera Lens In
21. in only one way If unable to insert the plug fully into the outlet try reversing the plug If the plug still fails to fit contact an electrician to arrange replacement of the obsolete outlet Do not defeat the safety purpose of the polarized plug Alternately this unit may be equipped with a 3 wire grounding plug a plug with a third pin for grounding This safety feature allows the plug to fit into a grounding power outlet only If unable to insert the plug into the outlet contact an electrician to arrange replacement of the obsolete outlet Do not defeat the safety purpose of the grounding plug Lightning For added protection during a lightning storm or when this unit is left unattended and unused for long periods of time unplug the unit from the wall outlet and disconnect the cable system This will prevent damage to the unit due to lightning and power line surges LTC 9385 Series Instruction Manual Safety Precautions For Indoor Product Safety Precautions 1 Water and Moisture Do not use this unit near water for example in a wet basement in an unprotected outdoor installation or in any area classified as a wet location Object and Liquid Entry Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electrical shock Never spill liquid of any kind on the unit Power Cord and Power Cord Protection
22. les en su pa s Desconexi n de la alimentaci n Las unidades con o sin interruptores de encendido apagado reciben alimentaci n el ctrica siempre que el cable de alimentaci n est conectado a la fuente de alimentaci n Sin embargo la unidad s lo funciona cuando el interruptor est en la posici n de encendido El cable de alimentaci n es la principal fuente de desconexi n de todas las unidades Bosch Security Systems January 26 2005 S curit ATTENTION RISQUE D LECTROCUTION NE PAS OUVRIR ATTENTION POUR EVITER TOUT RISQUE D ELECTROCUTION N ESSAYEZ PAS DE RETIRER LE CAPOT OU LE PANNEAU ARRI RE CET APPAREIL NE CONTIENT AUCUN COMPOSANT SUSCEPTIBLE D TRE REPARE PAR L UTILISATEUR CONFIEZ LA REPARATION DE L APPAREIL A DU PERSONNEL QUALIFIE Ce symbole signale que le produit renferme une tension potentiellement dangereuse non isol e susceptible de provoquer une lectrocution Ce symbole invite l utilisateur consulter les instructions d utilisation et d entretien d pannage reprises dans la documentation qui accompagne l appareil Attention l installation doit exclusivement tre r alis e par du personnel qualifi conform ment au code national d lectricit am ricain NEC ou au code d lectricit local en vigueur Coupure de l alimentation Qu ils soient pourvus ou non d un commutateur ON OFF tous les appareils re oivent de l nergie une fois le cordon branch
23. n NPT and one 3 8in NPT liquid tight fittings are preinstalled Liquid Tight Fittings in the rear of the base assembly If possible do not remove or loosen these parts They have been installed to a specified torque to prevent water damage The small 3 8in NPT fitting will accept cables with diameters from 4 6mm 0 18lin to 79mm 0 3lin The two large 1 2in NPT fittings will accept cables with diameters from 4 3mm 0 170in to 11 9mm 0 470in See FIGURE 6 Be sure to securely tighten all fittings to ensure a liquid tight seal Not doing so could damage the camera the housing or both If a sealant will be used be sure it is a neutral cure type Sealants that release acetic acid may harm camera electronics If it is necessary to use PG type conduit a TC9385PG kit is available The TC9385PG kit contains a wire grip with two PG11 and one PG7 tapped holes The NPT wire grip is removed and replaced with the PG version Dual Male Portion Seal Glands Flexible Portion FIGURE 6 Liquid tight Fitting Assembly Bosch Security Systems January 26 2005 5 8 Plug Insertion If no lens control or feed through wiring will be used install the 3 8in NPT plug provided Remove the liquid tight fitting and insert the plug in the small bottom center 3 8in NPT hole Use a 8mm or a 5 16in hex wrench to tighten securely Failure to do so will result in water damage to all electronic parts See FIG
24. porta un potenziale rischio di scosse elettriche Si consiglia di consultare le istruzioni operative e di manutenzione interventi tecnici contenute nella documentazione fornita con il dispositivo Attenzione l installazione deve essere effettuata esclusivamente da personale tecnico qualificato in conformit con il National Electrical Code o con le normative locali vigenti Scollegamento dell alimentazione Le unit dotate o sprovviste di interruttori ON OFF vengono alimentate quando si inserisce il cavo nella presa dell alimentazione L unit tuttavia in funzione solo quando l interruttore ON OFF si trova nella posizione ON Il corrente em todas as unidades cavo di alimentazione costituisce il dispositivo di scollegamento dell alimentazione principale per tutte le unit zeme HE ABRA TRARNE RA w AATRE SEEDARI AX BEM M S MINHA KESAR da PLEN EA ebe EJE XAF E HER BEA Att HI ENE A CER EE a BEL bri HH Ae EL CAI IET o Ur FEE FERRARA AAA ON OFF FARINA ER Elk AAE ON OFF FET ON EMA BETE HF PAIS Biet AEK EBA Bosch Security Systems January 26 2005 LTC 9385 Series Instruction Manual Contents Table of Contents Dopor dill AEDES qursost pa nese ead CE ebe ge dE DECR Ee 2 LO BH i E EENEG 7 20 SERVICE spears dada asd tia ds nda dad na eos PAR Fed E did knesset 7 30 GARE AND MAINTENANCE EEN 7 O DESCHREPLION DEE vi 4 1 Te e RAD oa cee assado dq sce Ea E CROSS DESDE O D
25. stallation Place the camera lens combination onto the rail assembly Fixed Lens Cameras Position the camera lens so that the lens is positioned over the heater but not past it Secure the camera to the rail assembly with the 1 4 20 x 3 8in BHC screw a nylon bushing and a 0 4mm 0 016in plastic spacer Place the nylon bushing over the screw and slide both between the rails through the front cut out section Slide the spacer over the screw so it is positioned in between the rails and the camera See FIGURE 4 FIGURE 4 Mounting a Fixed Lens Camera Zoom Lens Cameras Position the camera lens so that the lens is positioned over the heater but not past it The camera lens combination will determine the screws and spacers that will be needed Secure the camera and lens to the rail assembly with 1 4 20 BHC screws nylon bushings and plastic spacers Place the nylon bushings over the screws and slide both between the rails through the front cut out section Slide the spacer over the screw so it is positioned in between the rails and the camera There are four large spacers 3 2mm and four small spacers 0 4mm provided See FIGURE 5 FIGURE 5 Mounting a Zoom Lens Camera LTC 9385 Series Instruction Manual Installation 5 7 Camera Lens Wiring WARNING Only use the cables specified under INSTALLATION Cable Requirements for wiring of all cameras and lenses 5 7 1 The dual male threaded portion of the two 1 2i
26. sur la source d alimentation Toutefois l appareil ne fonctionne r ellement que lorsque le commutateur est r gl sur ON Le d branchement du cordon d alimentation permet de couper l alimentation des appareils Veiligheidsmaatregelen VOORZICHTIG NIET OPENEN VOORZICHTIG OPEN DE BEHUIZING OF DE ACHTERKANT VAN HET APPARAAT NIET ZO VERMINDERT U HET RISICO OP ELEKTRISCHE SCHOKKEN IN HET APPARAAT BEVINDEN ZICH GEEN ONDERDELEN DIE U ZELF KUNT REPAREREN LAAT SERVICE EN ONDERHOUD UITVOEREN DOOR GEKWALIFICEERD PERSONEEL Dit symbool geeft aan dat er binnen in het apparaat ongeisoleerde gevaarlijke spanning aanwezig is die mogelijk elektrische schokken kan veroorzaken De gebruiker dient de bedienings en onderhoudsvoorschriften te raadplegen in de documentatie die werd meegeleverd met het apparaat Attentie het apparaat mag alleen door gekwalificeerd personeel worden geinstalleerd De installatie dient in overeenstemming met de nationale elektrische richtlijnen of de van toepassing zijnde lokale richtlijnen te worden uitgevoerd Spanning uitschakelen Apparatuur met of zonder aan uitschakelaar staat onder spanning zolang de stekker is aangesloten op de wandcontactdoos De apparatuur is uitsluitend in werking als de aan uitschakelaar aan staat Het netsnoer is de hoofdschakelaar voor alle apparatuur LTC 9385 Series Instruction Manual Safety Precautions Medidas de Seguran a CUIDADO RISCO DE CHOQUE ELECTRICO NAO
27. t See FIGURE 13 NOTE Make sure the breather hole is located at the bottom of the housing If it is not remove both front retaining rings and the face plate Orient them so the breather hole is located at the bottom and the gaps in the retaining rings are centered over the breather hole See FIGURE 20 Base Assembly FIGURE 13 Base Assembly Rotation 5 12 Camera Lens Adjustment Before final assembly of the cover over the rest of housing verify camera and lens operation Adjust camera lens as necessary See individual camera instructions LTC 9385 Series Instruction Manual Installation 5 13 Final Assembly 513 1 Pull Seal Installation If the breather hole is open do NOT mount the housing in a position where the front face plate is pointed upward To maintain enclosure protection ratings of NEMA 4 and IP65 the pull seal provided in the hardware kit must be installed in the front face plate It is recommended that the pull seal be installed in a cool dry environment to prevent trapping moisture inside the housing See FIGURE 14 NOTE Pull seal installation allows the housing s front end to be pointed upward Breather Hole FIGURE 14 Breather Hole Proper installation of the pull seal is as follows 1 If the housing assembly is not already removed from the base assembly do so now see the Disassembly and Mounting section at the beginning of these instructions 2 Obtain a rubber pull
28. t Assembly M3 x 20 Screw Rivet 5 32in x 0 415in 2 Eye Cable Assembly M6 Flat Washer M6 Thin Hex Nut M6 Serrated Lock Washer 6 1 Terminal Block 230VAC Heater Bracket Assembly Kit 315 2811 001 7 1 Rail back Weldment 9 E 1 8 1 Ground Spring 1 16 3 M4 x 16 Low Socket Cap Screw 2 17 a 7 M4 Internal Star Lock Washer 18 1 76 32 x 5 8in Bosch Flat Head Two Eye Cable Assembly Kit 315 2812 001 Screw 10 1 19 2 8 Ring Tongue Terminal 13 1 20 E 3 M3 Philips Pan Head Screw 14 2 23 3 M4 Philips Pan Head Screw 15 2 1 115 VAC NEMA 5 15R Receptacle Faceplate Kit 315 2813 001 4 315 2300 900 2 Retaining Ring 500 24VAC Rail Assembly Kit 315 2807 001 5 315 2327 900 1 EP O ring 248 6 1 Terminal Block 12 1 Faceplate 7 1 Rail back Weldment 24 2 Rubber Pull Seal 8 S 1 Ground Spring 16 3 M4 x 16 Low Socket Cap Screw Housing Assembly 315 2814 001 17 7 M4 Internal Star Lock Washer 4 315 2300 900 2 Retaining Ring 500 18 1 6 32 x 5 8in Bosch Flat Head 11 1 Housing Assembly Screw 19 2 8 Ring Tongue Terminal Hardware Kit 315 2348 001 20 3 M3 Philips Pan Head Screw E 3 Cable Tie 23 3 M4 Philips Pan Head Screw 4 3 2mm Plastic Spacer 4 0 4mm Plastic Spacer 230VAC Rail Assembly Kit 315 2808 001 1 1 4 20 x 3 8in Button Head Screw 6 1 Terminal Block 1 1 4 20 x 1 2in Button Head Screw 7 1 Rail back Weldment 1 1 4 20 x 5 8in Button Head Screw 8 S 1 Ground Spring 1 1 4 20 x 3 4in B
29. utton Head Screw 16 3 M4 x 16 Low Socket Cap Screw 1 1 4 20 x 7 8in Button Head Screw 17 7 M4 Internal Star Lock Washer 1 3 8in NPT Plug 18 1 6 32 x 5 8in Bosch Flat Head E 1 Small Flex Fitting Screw 2 Large Flex Fitting 19 2 8 Ring Tongue Terminal 24 2 Pull Seal 20 3 M3 Philips Pan Head Screw 2 Nylon Bushing 23 3 M4 Philips Pan Head Screw 1 230VAC Schuko In Line Receptacle Americas Europe Middle East Africa Asia Pacific Bosch Security Systems 130 Perinton Parkway Fairport New York 14450 USA Phone 1 585 223 4060 Fax 1 585 223 9180 Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands E mail ema securitysystems bosch com http www boschsecurity com E mail security sales us bosch com www boschsecurity us 2005 Bosch Security Systems GmbH 3935 890 06612 05 04 Updated January 26 2005 Data subject to change without notice Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Singapore Phone 65 319 3488 Fax 65 319 3499 E mail sg securitysystems bosch com http www boschsecurity com BOSCH
Download Pdf Manuals
Related Search
Related Contents
Weslock 02241G1G1FR22 Instructions / Assembly Sommario - Hannspree Stiga MULTICLIP 8211-0223-07 User's Manual User`s Manual - ICP DAS USA`s I HP Jornada 420 User's Manual 技術部Newsletter Vol.1 Sun StorageTek Backup Manager Administration Guide Lorex LBC6040 surveillance camera Pioneer PRS-D3000SPL Stereo Amplifier User Manual Copyright © All rights reserved.