1. A DB9 to DB9 null modem cable is required when using the direct connection method DX40101 Installation Instructions 6 0 Remote Programming Direct Connection Table 3 Option Bus Address DIP Switch Settings Fase DIP Switch a Ses 128 Address ve pons cece 1 OnN OOF ORN Installer s mode Use for direct connection of remote programming and diagnostic tools DS7412 emulation The DS7400Xi USA only supports one DX4010i Option bus control panels D6412 D4412 DS7240 DS7220 DS7400Xi v2 02 or higher 8 Bosch Security Systems Inc 1 05 4998141106C DX40101 Installation Instructions 6 0 Remote Programming Direct Connection Table 4 SDI Bus Address DIP Switch Settings SDI DIP Switch Settings SDI DIP Switches Module 1 2 4 16 32 64 128 ON ON ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF Positions 5 6 and 8 are not used for SDI bus Used for BIS PC 9000 and other third party applications Used for RPS and alternate communication SDI bus control panels v6 0 or higher D9412G D7412G D7212G D9124 D9112 D7412 and D7212 Bosch Security Systems Inc 1 05 4998141106C 9 DX4010i Installation Instructions 7 0 DB9 DTE RS 232 Connector P6 7 0 DB9DTE RS 232 Figure 8 DB9 Connector Layout Connec
2. 32 F to 122 F 5 to 85 30 C 86 F non condensing Option bus control panels D6412 D4412 DS7240 DS7220 DS7400Xi v2 02 or higher SDI bus control panels v6 0 or higher D9412G D7412G D7212G D9124 D9112 D7412 and D7212 RPS supported on all compatible control panels PC 9000 supported on SDI Bus control panels D9412G D7412G D7212G D9112 D7412 and D7212 BIS supported on SDI Bus control panels v6 3 and higher D9412G D7412G and D7212G CMS 7000 supported on DS7400Xi Control Panels set at Mode 18 v3 09 or higher Printers supported on compatible Option Bus control panel Figure 1 DX4010i Component Layout DB9 GND enable pins P1 RJ 16 data bus connector P3 Data bus TS1 Address DIP switches S1 Diagnostic LEDs Diagnostic LED enable pins P2 DB9 DTE RS 232 connector P6 3 0 Installation Standards Failure to follow the instructions in this manual can result in personal injury or damage to the equipment The DX4010i contains static sensitive components and must be handled with care Follow anti static procedures when handling the modules amp Test according to NFPA 72 if used in fire applications 1 Disconnect power to the control panel by unplugging the transformer and removing the red battery lead 2 Remove screws from enclosure cover to access the DX4010i board 3 Connect circuit wiring and install jumper pins Refer to Section 4 0 Wiring on p
3. eee 4 Table 2 Diagnostic LED Functions 6 Table 3 Option Bus Address DIP Switch Settings 8 Table 4 SDI Bus Address DIP Switch Settings 9 Table 5 Alternate Wiring Configuration 10 Bosch Security Systems Inc 1 05 4998141106C 3 DX4010i Installation Instructions 1 0 General Information 1 0 General Information The DX4010i is a data terminal equipment DTE configured RS 232 serial device interface SDI module designed to operate with compatible control panels It connects to the control panel through the option or SDI data bus The DX4010i is used to connect a PC with RPS BIS PC 9000 CMS 7000 or other third party software that uses a serial conncetion to the supported control panels The module also supports a serial printer or parallel printer with a convertor box for control panels that support a serial printer The compatibility lists in Table 1 show support information 2 0 Specifications Table 1 DX4010i Specifications Operating Voltage Current Draw Communication Configuration 12 VDC 50 mA nominal 55 mA with diagnostic LEDs enabled Programmable through the control panel Refer to the appropriate control panel programming instructions The baud rate for the printer output on a DS7400Xi must be greater than 300 baud Operating Temperature Relative Humidity Control Panel Compatibility Application Compatibility 0 C to 50 C
4. Bosch Security Systems 130 Perinton Parkway Fairport NY 14450 9199 Customer Service 800 289 0096 Technical Support 888 886 6189 2005 Bosch Security Systems 4998141106C BOSCH
5. DX4010i Installation Instructions RS 232 Serial Interface EN Module DX4010i Installation Instructions Trademarks Trademarks e BlackBox is either a registered trademark or a trademark of BlackBox Corporation in the United States and or other countries 2 Bosch Security Systems Inc 1 05 4998141106C DX40101 Installation Instructions Contents Contents 1 0 General Information vvvrrrrrrsrrrrrssssesscsoceseo 4 2 0 Specificatioris scsi ciccione 4 3 0 Installation Standards cccccccssscccsssscccsees 4 4 0 l ICI 5 5 0 DX4010i Jumper Pin Settings ccsssess 6 Sel Enable LED Jumper Pins P2 n 6 5 2 DB9 Ground Enable Pins P1 6 5 3 Address DIP Switches 7 6 0 Remote Programming Direct Connection 7 7 0 DB9 DTE RS 232 Connector P6 10 8 0 RJ 16 Data Bus Connector P3 0sss0e 11 Figures Figure 1 DX4010i PCB Layout n 4 Figure 2 Control Panel Connections 5 Figure 3 External Power Supply Connections 5 Figure 4 Serial Device Connections 5 Figure 5 Parallel Device Connections 6 Figure 6 P2 Jamper Settings nare 6 Figure 7 DIP Switch Location Orientation 7 Figure 8 DB9 Connector Layout 10 Figure 9 Po Cometa 11 Tables Table 1 DX4010i Specifications
6. age 5 4 Replace enclosure cover 5 Connect a serial cable to the serial device Refer to Section 7 0 DBI DTE RS 232 Connector P6 on page 10 6 Reapply power to the control panel Bosch Security Systems Inc 1 05 4998141106C DX4010i Installation Instructions 4 0 Wiring 4 0 Wiring Remove all power to the control panel AC and standby battery before making or breaking any connections Failure to do so can result in personal injury or damage to the equipment Figure 3 External Power Supply Connections Wire Length Restrictions e 0 8 mm 22 AWG 305 m 1000 ft e 1 2 mm 18 AWG 610 m 2000 ft SDI wiring is limited to 305 m 1000 ft Connect the DX4010i to the control panel data and auxiliary power sources as shown in Figure 2 DX4010i data bus Control panel data bus Option AUX common SDI common black Option data SDI B green Option data SDI A yellow Option AUX power SDI power red External 12 VDC power supply Figure 2 Control Panel Connections Figure 4 shows serial device to DX4010i connections using the DB9 DTE RS 232 connector P6 DX40101 data bus Control panel data bus Option AUX common SDI common black Option data SDI B green Option data SDI A yellow Option AUX power SDI power red If an external 12 VDC power supply is used wire as Qo ENABLE shown in Figure 3 L _ gt 1 Serial RS 232 device such as a PC wit
7. h RPS BIS PC9000 or other third party application or a serial printer for supported control panels See Section 7 0 DB9 DTE RS 232 Connector P6 on page 10 for additional information Figure 5 shows a parallel printer connected to the serial output of the DX4010i This type of connection requires the use of a serial to parallel converter such as the BlackBox PI045A serial to Centronics parallel converter cable The cable is available from BlackBox www blackbox com Bosch Security Systems Inc 1 05 4998141106C 5 DX4010i Installation Instructions 5 0 DX4010i Jumper Pin Settings Figure 5 Parallel Device Connections Figure 6 P2 Jumper Settings 5 ee DB9 GND ENABLE Parallel converter cable box BlackBox P N PIO45A Diagnostic LED enable pins P2 Parallel printer compatible option bus control DB9 GND enable pins P1 panels only Enabled Disabled 5 0 DX4010i Jumper Pin Settings 5 1 Enable LED Jumper Pins P2 Use the diagnostic LEDs for troubleshooting To Diagnostic LED Function Table 2 Diagnostic LED Functions enable the LEDs place a jumper plug across the Data bus receives data from control jumper pins labeled P2 panel Refer to Figure 6 for jumper pin settings Data bus transmits data to control panel The DX4010i draws more current when the aa a SO eo seem ecleicouce diagnostic LEDs are enabled Do not RS 232 transmits data to serial device enable the d
8. iagnostic LEDs under normal IENE aisle Tels 5 2 DB9 Ground Enable Pins P1 Some devices connected to the DB9 DTE RS 232 connector P6 can cause a ground fault condition on the control panel If this occurs removing the plug across the P1 jumper pins can clear the ground fault condition Some devices might still cause a ground fault even if the P1 jumper plug is removed Refer to Figure 6 for jumper pin settings 6 Bosch Security Systems Inc 1 05 4998141106C DX4010i Installation Instructions 6 0 Remote Programming Direct Connection 5 3 Address DIP Switches The address DIP switches are used to assign an address to the DX4010i Refer to Table 3 for DIP switch option bus address settings Refer to Table 4 for DIP switch SDI bus address settings Refer to Figure 7 for proper DIP switch orientation Figure 7 DIP Switch Location and Orientation Address DIP switches ON position OFF position Address example option bus Address 0 Bosch Security Systems Inc 1 05 4998141106C 6 0 Remote Programming Direct Connection The DX4010i can be used to create a local direct connection for remote programming of a compatible control panel Option Bus Set the address DIP switches to Address 0 Refer to Table 3 on page 8 SDI Bus Set the address DIP switches to Address 88 Refer to Table 4 on page 9 Consult your control panel s installation guide for specific wiring connections
9. tor P6 The DX4010i serial port is wired as a DTE device Q 2 3 4 e If the connected device is a data carrier O O O O O equipment DCE device most common such as an external modem a straight through 9 pin to 9 pin or DTE to DCE 9 pin to 25 pin cable O oo may be used 7 6 DSR e Ifthe connected device is a DTE device such as a PC serial port a null modem DTE to DTE 9 pin to 9 pin or null modem 9 pin to 25 pin cable is required Consult the operating manual provided with your compatible device for wiring requirements If you are using an alternate configuration you must make a custom cable refer to Figure 8 and Table 5 Table 5 Alternate Wiring Configuration DX4010i DCE DTE DCE DTE 9 Pin DTE 9 pin 9 pin 25 pin 25 pin Connector 1 DCD not used 2 RxD TxD DTR GND DSR RTS CTS RI not used O 0 XY DU SW N BS li Ki K 10 Bosch Security Systems Inc 1 05 4998141106C DX4010i Installation Instructions 8 0 RJ 16 Data Bus Connector P3 8 0 RJ 16 Data Bus Connector P3 Figure 9 P3 Connector 1 RJ 16 data bus connector P3 For remote programming connection use one of the two cables supplied RJ 16 to molex for control panels with the data bus provided on a header such as the D6412 or DS7240 or the RJ 16 to spade lugs for terminal strip connections such as the D9412 Bosch Security Systems Inc 1 05 4998141106C 11