1. Function Color State Description Top LED Yellow ON Power OK in right power supply Bottom LED Yellow ON Power OK in left power supply Note Left right direction as viewed from the front of the chassis Left Power Supply Power Supply PS LEDs les A Right Power Supply Top Right PS gt gt PS gt a Bottom Left PS RS wm gt S gt ae ba x SITE PREPARATION REQUIREMENTS 1 Power Assure the 48VDC power can supply 3A of current 2 The operating temperature of this equipment is 0 40 degrees C If installed in a closed or multiunit rack assembly the operating ambient temperature of the rack must not exceed the maximum rated 40 degrees C temperature 3 Installation of the equipment should be such that the air flow in the front and back of the unit is not compromised or restricted 4 Never use this equipment to carry any weight except its own never use it as a shelf to support weight of other equipment 5 Installing this equipment into a rack in such a way as to make it unstable may Cause injury or death Always make sure that the rack you are installing this equipment into is properly secure stable balanced and designed to carry the weight and weight distribution of this equipment 6 When rack mounting this equipment the rack should be appropriately earth grounded 7 This equipment requires 48 VDC 3 0 Amps per power supply Appropriate overloading protection should be provided on all DC power source
2. Hot Attachment of Power Supplies 1 Unpack the power supply carefully Inspect for any damages If any damage is observed do not use the power supply and call 949 250 6510 to report the damage immediately and request a replacement unit 2 Attach the power supply to the chassis and reconnect the 48VDC power source to the FlexPoint power supply 3 Locate the 48VDC circuit breaker and switch the circuit breaker to the ON position 4 Turn the FlexPoint Chassis power supply ON 5 Observe the LED in the front of the chassis indicating that the power has been restored SPECIFICATION E Indicators Power ON LED 2 Yellow power applied m Dimensions Weight W 19 0 xD 7 0 xH 3 5 9 lb E Power 48VDC 3 0 Amps for model 4386 2ea 48VDC 3 0 Amps for model 4385 mE Environmental Temperature 0 to 40 degrees C Humidity 0 90 non condensing LN LO Black Box Corporation A Jetwork Connectivity Copyright 1999 2001 Black Box Corporation All rights reserved A a 1000 Park Drive e Lawrence PA 15055 1018 e 724 746 5500 e Fax 724 746 0746 LS Black Box Corporation IN The World s Source for Cabling and Network Connectivity JULY 2001 LMC200A 2PS DC LMC200A DC PSFP20 DC FlexPoint Powered Chassis 48V Power Redundant 14 Module Chassis User s Manual CUSTOMER Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 SUPPORT FREE technical support 24 hours a day 7 days a
3. a do o l quido ha sido derramado dentro del aparato o El aparato ha sido expuesto a la lluvia o El aparato parece no operar normalmente o muestra un cambio en su desempe o o El aparto ha sido tirado o su cubierta ha sido da ada A Po gt MUY It is very strongly recommended that a replacement power supply unit be installed as soon as possible in order to prevent overheating of the chassis unit THE POWER SUPPLIES ARE HOT SWAPPABLE AND CAN BE REPLACED WITHOUT SHUTTING THE NETWORK DOWN HOWEVER WHEN REMOVING AND REPLACING A POWER SUPPLY UNIT THE FOLLOWING STEPS MUST BE STRICTLY FOLLOWED IN ORDER TO PREVENT SERIOUS INJURY OR DEATH OR SERIOUS DAMAGE TO YOUR EQUIPMENT y x F NM E Power Supply Mounting Screws Power Supply Mounting Screws and guide pins and guide pins 2 each per unit 2 each per unit Hot Removal of Power Supplies 1 Determine which power supply needs replacing by observing the LEDs in the front left of the chassis the top LED indicates the power status of the right power supply as observed from the front the bottom LED indicates the power status of the left power supply as observed from the front Notice that LED being ON indicates that the power supply is operational The LED being OFF may indicate that the DC power is not applied please verify that your DC power source is providing power 2 Once you determine that y
4. a cama sof alfombra or superficie similar puede bloquea la ventilaci n no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u ostros aparatos incluyendo amplificadores que producen calor 11 El aparato el ctrico deber ser connectado a una fuente de poder s lo del tipo descrito en el instructivo de operaci n o como se indique en el aparato 12 Precaci n debe ser tomada de tal manera que la tierra fisica y la polarizaci n del equipo no sea eliminada 13 Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atenci n a los contactos y recept culos donde salen del aparato 14 El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante 15 En caso de existir una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilaci n 18 Servicio por personal calificado deber ser provisto cuando gt El cable de poder o el contacto ha sido da ado u Objectos han c
5. hing electrode is connected b This equipment shall be located in the same immediate area such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor and also the point of earthing of the DC system The DC system shall not be earthed elswere c The DC supply source is to be located within the same premises as this equipment d There shall be no switching or disconnecting devices in the earthed circuit conductor between the DC source and the earthing electrode conductor
6. our DC source is connected properly and the power supply LED is still not ON determine which is the failing power supply unit and proceed to the next step 3 Locate the 48VDC circuit breaker and switch the circuit breaker to the OFF position 4 Remove the DC power cables of the faulty power supply from the FlexPoint power supply unit 5 Loosen the 2 screws securing the power supply to the main chassis observe the illustration on page 7 6 Remove the faulty power supply 6 Cabling and Power Up 1 Insure that both FlexPoint Chassis power supply switches are in the OFF position 2 Assure that the 48VDC circuit breaker can supply 3A of current per power supply 3 Locate the 48VDC circuit breaker and switch the 48VDC circuit breaker to the OFF position 4 Cut the power cable to the length required 5 Strip approximately 3 8 of an inch of insulation from the power cable wires 6 Connect the power cables to the FlexPoint Chassis by fastening the stripped ends to the 48VDC connector WARNING Note the wire colors used for making the positive negative and ground connections Use the same color assignment for the connection at the circuit breaker 7 Connect the power cable to the circuit breaker and switch the circuit breaker ON 8 Turn both FlexPoint Chassis power supply switches on and check the power LED s on the front panel of the powered chassis The two LED s should be ON 9 Attach the L shaped tabs to
7. outlets utilized 5 8 Wiring methods used for the connection of the equipment to the primary power supply shall be in accordance with the National Electrical Code ANSI NFPA 70 and the Canadian Electrical Code Part C22 1 UNPACKING a Visual Inspection Inspect equipment in order to detect any physical damage Any evidence of damage should be noted and reported immediately INVENTORY Review contents the following items should be included FlexPoint Powered Chassis unit Power supplies 2 for model LMC200A 2PS DC 1 for model LMC200A DC L shape tabs Screws 1 2 1 4 1 User s manual this document aon ee eS a KYM Please note any missing items or discrepancies and report them immediately INSTALLATION WARNING Only a DC power source that complies with safety extra low voltage SLEV requirements can be connected to the DC input power supply Tools and Equipment Required Flat head screwdriver not supplied Wire cutter stripper not supplied Three conductor 14 AWG copper power cable recommended not supplied Preparation Assure that the FlexPoint Chassis is physically installed in accordance with the Site Preparation Requirements outlined earlier in this document WARNING REGARDING EARTHING GROUND a This equipment shall be connected to the DC supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system eart
8. t of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num irques de las classe A prescrites dans le Reglement sur le brouillage radio lectrique publi par le minist re des Communications du Canada NORMAS OFICIALES MEXICANAS NOM ELECTRICAL SAFETY STATEMENT 1 Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que el aparato el ctrico sea operado Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura Todas las advertencias en el aparato el ctrico y en sus instrucciones de operaci n deben ser respetadas Todas las instrucciones de operaci n y uso deben ser seguidas El aparato el ctrico no deber ser usado cerca del agua por ejemplo cerca de la tina de ba o lavabo s tano mojado o cerca de una alberca etc El aparato el ctrico debe ser usado nicamente con carritos o pedelstales que sean recomendados por el fabricante El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las instrucciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado 9 El aparato el ctrico debe ser situado de tal manera que su posici n no interfiera su uso La colocaci n del aparato el ctrico sobre un
9. the FlexPoint media converter units to be inserted into the chassis Secure the FlexPoint module using the enclosed screws Nee 10 Save the unused tabs in a safe place or secure them to the chassis unused Slots POWER SUPPLY REPLACEMENT WARNING NEVER ATTEMPT TO OPEN OR SERVICE THE POWER SUPPLY UNIT OPENING THE POWER SUPPLY UNIT MAY CAUSE SERIOUS INJURY OR DEATH The Powered Chassis is intended to be used with two power supplies in a power redundant operation A failure of a single supply should not disturb the operation of the chassis unit However certain power supply failures may cause a secondary failure to the associated fan and cause undesired overheating of the chassis unit FlexPoint Powered Chassis User s Manual GENERAL DESCRIPTION The FlexPoint Powered Chassis is a chassis capable of holding up to 14 FlexPoint media converter modules Itis equipped with two power supplies in a power redundant configuration This User s Manual describes the following models Model Description LMC200A 2PS DC Powered Chassis rack mountable chassis 2 power supplies LMC200A DC Powered Chassis rack mountable chassis 1 power supply PSFP20 DC Power supply unit for models LMC200A 2PS DC and LMC200A DC 4 CONTROLS AND INDICATORS LEDs Display The Powered Chassis features two LEDs on the left front of the chassis these LEDs display the status of the two power supplies
10. week Call 724 746 5500 or fax 724 746 0746 INFORMATION Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com TRADEMARKS All applied for and registered trademarks are the property of their respective owners FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates uses and can radiate radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to be cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Departmen