Home
Black Box TV Converter Box Industrial SFP/SFP Multi-Power Mode Converter User's Manual
Contents
1. of the SFPs and the numerous fiber modes and types available in SFPs allow for easy configuration and future upgrading as network demands evolve The SFP modules must be MSA compliant and Support the same speed range The Industrial SFP SFP operates as a mode converter only and not as a rate converter The Industrial SFP SFP does not provide support for copper TX SFPs 2 1 Features The Industrial SFP SFP provides the ability to change optical transport characteristics using easy to install SFP devices This mix and match functionality is only limited by the available Black Box SFP units For more information about SFPs visit https www blackbox com The key features of the Industrial SFP SFP are Uses Miniature Media Converter Form Factor supports a 7 VDC to 50 VDC terminal block option with cascading power Supports an external 5 VDC power option not extended temperature Allows extended temperature range from 13 F to 185 F 25 C to 85 C Uses all standard MSA complaint SFP devices excluding copper SFPs Provides extensive diagnostic LED functions Supports DIN Rail mounting LGC300A R2 724 746 5500 blackbox com Page 7 Chapter 3 Install the Industrial SFP SFP Multi Power Mode Converter 3 Install the Industrial SFP SFP Multi Power Mode Converter The Industrial SFP SFP Multi Power Mode Converter installs anywhere as a standalone table top device or on a DIN rail As a standalone device install it in locations with lim
2. LGC300A R2 BLACK BOX NETWORK SERVICES dne Converts any fiber optics type interface to any other fiber optics type interface Customer Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 Support FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax Information 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Website www blackbox com E mail info blackbox com FCC and IC RFI Statements FCC and Industry Canada RF Interference Statements Class B Digital Device This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation However there is no guarantee that interference will not occur in a particular installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications If this equipment does cause harmful interference to radio or telephone reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equ
3. id signal is detected an active fault on transmitter by the SFP and LED transmitter Is not in LOS indication fault on receiver One or both SFPs Indicates that both are not installed or SFPs with the same not detected The speed are securely TX inhibit must not installed be active if a SFP is missing Or both SFPs are installed but their speed settings are different This condition disables both SFPs To help in troubleshooting the Link Loss LL feature is always ON That is ifa LOS is detected on an incoming SFP port the Optical transmitter on the other SFP port is turned OFF This provides a Link Loss carry forward function to alert the device downstream of the existing problem This function is ON in both directions at the same time The LL function is inhibited if either SFP is not installed LGC300A R2 724 746 5500 blackbox com Page 11 Chapter 5 Contacting Black Box 5 Contacting Black Box Black Box Customer Service Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 Free technical support 24 hours a day 7 days a week Call 724 746 5500 or Fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com WARNING Disconnect all power supplies before servicing Page 12 724 746 5500 blackbox com LGC300A R2 Chapter 6 Fiber Optic Cleaning Guidelines 6 Fiber O
4. ipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult an experienced radio TV technician for help CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment To meet FCC requirements shielded cables and power cords are required to connect this device to a personal computer or other Class B certified device This digital apparatus does not exceed the Class B limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada Page 2 724 746 5500 blackbox com LGC300A R2 Certifications Certifications CE Class 1 Laser product Luokan 1 Laserlaite Laser Klasse 1 Appareil A Laser de Classe European Directive 2002 96 EC WEEE requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indicates that the eguipment should be disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information about pr
5. ited space lf multiple connections are required use an IE PowerTray 18 enclosure sold separately The tray allows for 18 conversions in a 1 5 rack unit of space The units can also be powered by daisy chaining DC power refer to Cascading DC Power 3 1 SFP Port Requirements The Industrial SFP SFP Multi Power Mode Converter requires two SFP Modules of the same speed either two Fast Ethernet 100Mbps modules or two Gigabit Ethernet 1000Mbps modules 3 2 DIN Rail Mounting The Industrial SFP SFP Multi Power Mode Converter includes two DIN clips allowing installation on a DIN rail It mounts perpendicular to the DIN rail as shown Use the supplied screws to attach the DIN clips to the Industrial SFP SFP and then snap the converter to the DIN rail L t To remove the converter from the DIN rail use a flat head screwdriver in the slot to gently pry the converter from the rail NA or 5 m men m ua mi mem E m m MI MENE mi h i p ee d E Seles ee Se Ma FE rani NOTE The DIN clips are designed for use on a DIN 35 rail 3 3 Powering the Industrial SFP SFP Multi Power Mode Converter The Industrial SFP SFP Multi Power Mode Converter reguires an external DC power source and has three options for powering as options e Universal AC power adapter with country specific clip not included with module version Page 8 724 746 5500 blackbox com LGC300A R2 Chapter 3 Install the Industria
6. l SFP SFP Multi Power Mode Converter e User supplied LPS DC power via a four position DC power block e Power from an Power Tray 18 Slot DC For extended temperature operation the DC terminal block must be used because the supplied AC to DC converter is not rated for extended temperature operation The power source used with the DC terminal block should be a Limited Power Source LPS 3 3 1 DC Terminal Block Option The Industrial SFP SFP DC power option includes a 7 VDC to 50 VDC terminal block and a standard 5 VDC mini jack The DC terminal block has multiple DC inputs intended for cascading DC power to an adjacent unit DOO C GROUND common 5 VDC 7 to 50VDC Connect the power source to any one positive and one negative terminal on the Industrial SFP SFP When using stranded wire the leads must be tinned The chassis is not protected against mis wiring if mis wired the chassis will not function The chassis is internally connected to the negative power terminal 3 3 2 Cascading DC Power If installing multiple Industrial SFP SFPs on a DIN rail you can use one DC input source and then cascade from one DC terminal block to the next until reaching the maximum electrical current available LGC300A R2 724 746 5500 blackbox com Page 9 Chapter 3 Install the Industrial SFP SFP Multi Power Mode Converter 3 4 DC Power Supply Precautions The following precautions must be observed when installing the chassi
7. lackbox com Page 5 Chapter 1 Specifications 1 Specifications DC Input 47 VDC to 450 VDC 2 5 watts Actual current consumption may vary depending on the type of SFP modules installed When not using the supplied AC DC converter the externally supplied DC power must be provided from a LPS source AC Wall Adapter 100 to 240 10 VAC input 5 VDC output 2A max Operating 13 F to 185 F 25 C to 85 C DC configuration Temperature 14 to 122 F 10 C to 50 C with Franmar AC wall adapter 49 F to 185 F 45 C to 85 C Shipping Weight 0 25 Ibs 0 11 kg 0 83 H x 1 80 W x 3 35 D 2 11 x 4 57 x 8 51 cm 1 1 Standards Compliance e SFP MSA SFP standard September 14 2000 e SFF 8472 DDMI standard Revision 1 0 All SFPs used in this product should be certified to IEF 60825 1 Page 6 724 746 5500 blackbox com LGC300A R2 Chapter 2 Overview 2 Overview About the Industrial SFP SFP Multi Power Mode Converter The Industrial SFP SFP is a pure mode converter that converts any fiber optics type to any other fiber optics type This product is a Protocol independent converter and is not intended for applications that require retiming or any Layer 2 functions The Industrial SFP SFP supports extended temperature operation The Industrial SFP SFP requires two small form factor SFP modules sold separately which provide greater fiber flexibility in the network environment The hot swappable nature
8. om its protective packaging until ready to install 2 Wear an ESD wrist grounding strap before handling any module or component If the wrist strap is not available maintain grounded contact with the system unit throughout any procedure requiring ESD protection 3 Hold the units by the edges do not touch the electronic components or gold connectors 4 After removal always place the boards on a grounded static free surface ESD pad or in a proper ESD bag Do not slide the modules or stand alone units over any surface WARNING Integrated circuits and fiber optic components are extremely susceptible to electrostatic discharge damage Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices Page 14 724 746 5500 blackbox com LGC300A R2 Notes LGC300A R2 724 746 5500 blackbox com Page 15 Black Box Tech Support FREE Live 24 7 4 Tech support the way it should be R i F H Ad i Great tech support is just 30 seconds away at 724 746 5500 or blackbox com BLACK BOX NETWORK SERVICES About Black Box Black Box Network Services is your source for more than 118 000 networking and infrastructure products You ll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 30 seconds or les
9. oper disposal please contact local authorities waste disposal services or the point of purchase for this equipment LGC300A R2 724 746 5500 blackbox com Page 3 Table of Contents Table of Contents A oe po a o N ENE ie ae O eee es ine 5 1 SPO CON s eee ne ne anne pen te cata Oe oe ee eee ree ee EN 6 1 1 Staladards GOMPNANCE reattore 6 2 Overview About the Industrial SFP SFP Multi Power Mode OI ile AE EEN nau EO NR rn 7 2 1 o a A EI OE RE RE JA 7 3 Install the Industrial SFP SFP Multi Power Mode Converter 8 3 1 SFP POME NEGU EMONI S aa ea Na ej ae 8 3 2 DIN Rail MOUNTING inn svetne obo ee A ea be see 8 33 Powering the Industrial SFP SFP Multi Power Mode Converter 8 3 3 1 DC Terminal Block ODUONM issiron ieaie 9 3 3 2 Cascading DG ROWER inner jene a arko one baeji 9 3 4 DC Power Supply Precautions ne 10 4 Operaa een cee eee ie nt eer me na ere er er NE IME PET MERA RA NIM 11 4 1 ED OSL AU OM a T 11 5 CONTACTING Black BOX vessadecacnsrsinch scence sdonctdesanecsenscade a A EME MENIM 12 6 Fiber Optic Cleaning Guidelines cccccecccecsseeeeeeseeeeesseeeeeseaeeeeeeas 13 f Electrostatic Discharge Precautions 14 Page 4 724 746 5500 blackbox com LGC300A R2 Part Numbers Part Numbers Part Number Description O O Z o Y LGC300A R2 MultiPower SFP to SFP Mode Converter SFPs sold separately LGC300A R2 724 746 5500 b
10. ptic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust which can obstruct the optic path and cause performance degradation Good system performance requires clean optics and connector ferrules 1 Use fiber patch cords or connectors if you terminate your own fiber only from a reputable supplier low guality components can cause many hard to diagnose problems in an installation 2 Dust caps are installed at Black Box to ensure factory clean optical devices These protective caps should not be removed until the moment of connecting the fiber cable to the device If you need to disconnect the fiber device reinstall the protective dust caps 3 Store spare caps in a dust free environment such as a sealed plastic bag or box so that when reinstalled they do not introduce any contamination to the optics 4 If you suspect that the optics have been contaminated alternate between blasting with clean dry compressed air and flushing with methanol to remove particles of dirt LGC300A R2 724 746 5500 blackbox com Page 13 Chapter 7 Electrostatic Discharge Precautions 7 Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to any product add in modules or stand alone units containing electronic components Always observe the following precautions when installing or handling these kinds of products 1 Do not remove unit fr
11. s Copyright 2010 Black Box Corporation All rights reserved Printed in U S A Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Double Diamond is a trademark of BB Technologies Inc Any third party trademarks appearing in this publication are acknowledged to be the property of their respective owners LGC300A R2 Rev 1 55 80619BB 00 Rev B1 724 746 5500 blackbox com
12. s model with an internal DC power supply 1 Check nameplate ratings to ensure there is no overloading of supply circuits that could effect overcurrent protection and supply wiring 2 In addition the following must be observed a Connect the equipment to a 35 to 50 VDC power source that is electrically isolated from the alternating current source The 35 to 50 VDC power source is connected to a SELV DC source b Route input wiring to terminal block and secure in such a manner that it is protected from damage and stress Do not route wiring past sharp edges or moving parts c Incorporate a readily accessible disconnect device with a 3mm minimum contact gap in the fixed wiring 3 Reliable Grounding of this equipment must be maintained Particular attention should be given to supply connections when connecting to power strips rather than direct connections to the branch circuit Page 10 724 746 5500 blackbox com LGC300A R2 Chapter 4 Operation 4 Operation The Industrial SFP SFP contains four status LED indicators Each LED is dual color and has three states off red or green A loss of signal on one SFP causes the TX of the other SFP to turn off This action does not activate the red TX Fault LED Red OFF Green Card does not pass Unit does not Power is applied to the the self test have power card All internal self test functions must pass before the PWR LED is LED transmitter has No active fault Val
Download Pdf Manuals