1. Last SAL 17 Temperature GaUgE ssp 18 Installing the 3 Slot Desktop Chassis oooooocccoccconocononanonnonnnonnnonnnonnnono 18 DC Power Wiring Replacing Power Supply and Fans oooomomommommo o 19 DC Power Supply Wiring Instructions ooooocononcconononoconacinaconaconanonnos 19 Power Supply Modules oooooocooccooccconncconoconaconaconnconanonnnconn cono connnonnos 19 Pa e e o RSA NANNA IANA 20 Installing Management and Application Modules 20 Installing Applications Modules oooooococccococonocononanonanonnncnnnononon ono 20 SNMP Write LOKA an a 21 SNMP Management Module LEDS 00 21 3 Slot Desktop Chassis Specifications ooooooocococcnococonocanocanonanoranonanonnnos 22 Hardware Feature Matrix ida 22 Black BOX Guslomer Servie ect E TE 23 Fiber Optic Cleaning Guidelines eee eee etern 24 Electrostatic Discharge Precautions ccccccccccnonononnnoococonononononononananoss 24 CSTE CU OLN roces 25 yi Part Numbers 20 Slot Rackmount Chassis Part Number Description LMC5200A SNMP Management Module LMC5207A R2 20 Slot w Dual AC Power LMC5208A R2 20 Slot wDual DC Power LMC5227A R2 20 Slot W Fixed Single AC Power LMC5228A 20 Slot wACDC Power Back Up Spares Sold Separately 6 Slot Rackmount Desktop Chassis Back Up Spares Sold Separately LMC5213A
2. DC Power Supply LMC5214A AC Power Supply 3 Slot Desktop Chassis Part Number Power Supply 2 LMC5233A 3 Slot w AC Power LMC5234A 3 Slot w Dual AC Power LMC5235A 3 Slot w DC Power LMC5236A 3 Slot w Dual DC Power LMC5237A 3 Slot w ACDC Power Back Up Spares Sold Separately LMC5200A SNMP Management Module includes Black Box and iView LMC5238A 19 inch Rackmount shelf and screws About the 20 Slot Rackmount Chassis The 20 Slot Rackmount Chassis series is a modular chassis platform designed for use with Black Box Simple Network Management Protocol SNMP manageable series of modules The 20 Slot Rackmount Chassis is a 3U high Rackmountable chassis that features 20 slots for installing application series modules plus an additional slot for installing an SNMP Management Module Some 20 Slot Rackmount Chassis models are capable of redundant power supply modules Power supply modules are user replaceable and hot swappable 20 Slot Rackmount Chassis Features The 20 Slot Rackmount Chassis offers models available in dual AC dual DC and ACDC versions It offers features such as end user replaceable power supply modules temperature monitoring Last Gasp and an Alarm Reset Button x si hy TE E ja 8 z Media Converter System Soe ETE 4 Y 1 Tor y q dl ae Alarm Reset Last Gasp and Temperature Gauge The 20 Slot Rackmount Chassis series supports power supply modules so that worn p
3. Secure the module to the chassis by tightening the captive screw Refer to the documentation shipped with the module for configuration information In order to manage a Desktop Chassis the SNMP Management Module needs to be installed in the appropriate slot of the chassis e Install the 3 Slot Desktop Chassis slot SNMP Management Module into the a bottom left slot This slot is ONLY for the Management Module do not install Application Modules such as media conversion and mode conversion modules in this slot 150 Fog oH High Density 3 Slot Media Converter System EF S LHE LUE 0 a a 14 gan bpm ia g GNAP At GaP ENT TEF FEU data Fcu DaTh 150 Fox pi FTL Lai F ss ss 27 2 s E ss 20 SNMP Write Lock The SNMP Write Lock switch is located on the back of the 3 Slot Desktop Chassis The SNMP Write Lock switch prevents a new management board from re configuring the application module settings e g the status of features such as LinkLoss FiberAlert Force mode etc made via SNMP on any previous Management Modules norma Locke Leave this switch in the NORMAL position during day to day operation the LOCKED position should only be used when changing the SNMP management board The SNMP Management Module can be removed and replaced as necessary Refer to the SNMP Management Module manual for complete instructions about how to configure and operate If an SNMP
4. a reliable filtered power source 5 lf mounting the chassis on a wall place two 10 panhead screws not supplied on the wall according to the distance of the holes on the chassis and then hang the unit on the screws 6 All versions are intended for use in a Restricted Access Location RAL 18 7 A readily accessible disconnect device shall be incorporated in the building installation wiring 8 A suitable listed circuit breaker shall be provided in the building installation as the unit s disconnect device The branch circuit rating i e minimum 15A listed circuit breaker etc DC Power Wiring Replacing Power Supply and Fans DC Power Supply Wiring Instructions The following image shows the wiring configuration for a 48 VDC power supply in a negative ground system application For positive ground system applications remove the chassis ground shorting jumper and connect it between the positive terminal and the chassis ground terminal Alternatively the chassis grounding jumper can be eliminated and the chassis ground connected at the power source The ground terminal and the negative terminal are not connected inside the iMediaChassis 3 DC Power Supply Negative ground system configuration default position DG Power Supply l Negative ground system configuration Factory Configuration Terminal Block Chassis Grove Jumper Incorrect wiring will result in chassis malfunction The 3 Slot Desktop Chassis is complian
5. required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la classe A prescrites dans le R glement sur le brouillage radio lectrique publi par le Industrie Canada Class B Class B Digital Device This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation However there is no guarantee that interference will not occur in a particular installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications If this equipment does cause harmful interference to radio or telephone reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures e Reorie
6. tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atenci n a los contactos y recept culos donde salen del aparato El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante En caso de existir una antena externa deber ser localizada lejos de las l neas de energ a El cable de corriente deber ser desconectado cuando el equipo no sea usado por un largo per odo de tiempo Cuidado debe ser tomado de tal manera que objecos l quidos no sean derramados sobre la cubierta u orificios de ventilaci n Servicio por personal calificado deber ser provisto cuando El cable de poder o el contacto ha sido da ado u a b Objectos han ca do o l quido ha sido derramado dentro del aparato o z El aparato ha sido expuesto a la lluvia o d El aparato parece no operar normalmente o muestra un cambio en su desempe o o e El aparato ha sido tirado o su cubierta ha sido da ada Table of Contents FCC and Industry Canada RF Interference Statement ccccccssssssseeeeees il Normas Oficiales Mexicanas NOM Electrical Safety Statement iii Pan NONDE eee o e A 1 S 20 Slot Rackmount Chassis c cccccccsscccsscesseccssecessecesseceseecssesesesessesesseenseeens 1 Back Up Spares Sold Separately oooooooooococononcconcconnoranocinccrnnonanoso 1 6 Slot Rackmount Desktop Chassis c
7. 77 877 BBOX outside U S call 724 746 5500 Free technical support 24 hours a day 7 days a week Call 724 746 5500 or Fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com WARNING Disconnect all power supplies before servicing 23 Fiber Optic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust which can obstruct the optic path and cause performance degradation Good system performance requires clean optics and connector ferrules 1 Use fiber patch cords or connectors if you terminate your own fiber only from a reputable supplier low quality components can cause many hard to diagnose problems in an installation 2 Dust caps are installed at Black Box to ensure factory clean optical devices These protective caps should not be removed until the moment of connecting the fiber cable to the device Should it be necessary to disconnect the fiber device reinstall the protective dust caps 3 Store spare caps in a dust free environment such as a sealed plastic bag or box so that when reinstalled they do not introduce any contamination to the optics 4 If it is suspected that the optics have been contaminated alternate between blasting with clean dry compressed air and flushing with methanol to remove particles of dirt Electrostatic Discharge Pre
8. BLACK BOX LMC5207A R2 LMC5228A LMC5205A LMC5234A LMC5227A LMC5208A R2 LMC5203A LMC5206A LMC5235A NETWORK SERVICES LMC5227A R2 LMC5204A LMC5233A LMC5236A Choose from a wide variety of chassis and mod build a powerful media converter solt DK BOX High Density 3 Slot Modia Corverter System an soe i fd b a e l M La Pl Fl as a 2 Y E LJ RA ee Customer Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 Support FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax Information 724 746 0746 e Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 e Web site www blackbox com e E mail info blackbox com FCC and Industry Canada RF Interference Statements Class A This equipment generates uses and can radiate radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be
9. High Density 3 Slot Media Converter System rr FA FT LALA E A E br ow 110 y r T 4 P le e gt f ap i i aH FA FTL LAAT Managed ll Alarm Reset Last Gasp and Temperature Gauge The 3 Slot Desktop Chassis ships with one or two AC or DC power supply modules depending on the model Fans are included in all models Alarm Reset Button When one power supply module malfunctions an audible alarm sounds indicating the loss of the power supply The alarm can be silenced by pressing the Alarm Reset Button located next to the power connector on the power supply module If this occurs the unit needs to be returned to Black Box for repair Last Gasp Alarm The 3 Slot Desktop Chassis includes the Last Gasp trap feature Remote Chassis Down which sends a Trap when the following occurs Both power supply modules malfunction Both power supply modules are powered down When the AC line fails 17 Temperature Gauge The 3 Slot Desktop Chassis includes a temperature monitoring gauge with a heat sensor on the backplane of the chassis Users define a threshold for chassis temperature via SNMP If the chassis temperature rises above the specified level the SNMP agent sends a trap configured in iView2 to the administrator There is also an LED indicator on the SNMP Management Module for chassis temperature Installing the 3 Slot Deskt
10. MC5228A Vernes 10 20 Slot Rackmount Chassis Specifications ccccccccceceeeesssseeeeeeeceeeeeees 10 About the 6 Slot Rackmount Desktop Chassis ooooooooooocccccnnnnnnnnnnos 11 6 Slot Rackmount Desktop Chassis Features 11 Alarm Reset Last Gasp and Temperature Gauge oooccoocconcconncconcconacinncnno 11 Alarm Reset Button 11 Last Gasp Alarm ENNI RI I 11 Temperature GaUge sas a ganginn anal augl 12 SNMP Write Lock snert 12 SNMP Management Module LEDS ooooocococoncconcconccnonocinocinocoo 12 Installing the 6 Slot Rackmount Desktop Chassis oooooccconcconcconocinnooso 13 DC Power Wiring Replacing Power Supply and Fans oooooomoommmmo oo 14 V DC Power Supply Wiring INStrUCtIONS ooccoonocnnocncnnccnacnccnannaannnonnonnonnonnonncnnss 14 User Replaceable Power Supplies ooooooooococonccconaconncconnoronaconnncnnnos 14 A e ES A 14 Installing Management and Application Modules 15 Installing Applications Modules oooooococcconcconocanonanonanonnnonnnonononnnons 15 6 Slot Rackmount Desktop Chassis Specifications 000 16 About the 3 Slot Desktop Chassis oooooooccccccocnnnonononononanccncnononnnnnnnnnns 17 3 Slot Desktop Chassis Features 17 Alarm Reset Last Gasp and Temperature Gauge oooccoocconcconncooncconaconnonno 17 Alarm Reset BOUTON rra 17
11. Management Module is installed refer to the LED panel below for indicators of Link Temperature Power Supply modules and other functions SNMP Management Module LEDs The SNMP Management Module features several LEDs The LED functions are LNK ACT Glows green when a link is established on port Blinks green when data activity occurs os a FDX COL Glows yellow when port isin Full Duplex mode A Blinks yellow when port is operating in Half SA Duplex mode and collisions occur TEMP Glows yellow when temperature of unit surpasses a user defined level PS Glows yellow when one power supply module malfunctions FAN A FAN B Glows yellow when a fan malfunctions A 4 FOX CAL TEMP FANA FANE 21 3 Slot Desktop Chassis Specifications Input Specifications 100 to 240V AC 50 60Hz 0 75A 35V DC to 75V DC Max 1 6A Operating Temperature 0 Cto 50 C 32 F to 122 F 40 C to 50 C 67 F to 122 F Storage Temperature 40 C to 85 C 40 F to 185 F 55 Cto 125 C 40 F to 212 F Humidity 5 to 95 non condensing O to 10 000 ft altitude Shipping Weight 5 lbs 2 3 kg Dimensions H 1 73 W 7 45 D 8 74 4 4 x 19x 22 cm Hardware Feature Matrix Power Supply 3 Slot Desktop Chassis Redundant upgrade on single slot chassis Trap can be set for exceeding a temperature value 22 Black Box Customer Service Order toll free in the U S Call 8
12. This slot is ONLY for the Management Module do not install Application Modules such as media conversion and mode conversion modules into this slot 15 6 Slot Rackmount Desktop Chassis Specifications Input Specifications Dual AC Input 90 264VAC 47 63 Hz 1 84 O 100V 0 8A 240V Dual DC Input 35 75VDC 3 3A Operating Temperature 25 C to 50 C 130 F 122 F 40 C to 100 C 40 F 212 F Storage Temperature 40 C to 85 C 40 F 185 F 55 Cto 125 C 67 F 257 F Humidity 5 95 non condensing 0 10 000 ft altitude Shipping Weight 13 lbs 5 90 kg Dimensions 1 75 x 17 35 x 10 65 4 45cm x 44 07cm x 27 05cm 16 About the 3 Slot Desktop Chassis The 3 Slot Desktop Chassis series is a modular chassis platform designed for use with Black Box Simple Network Management Protocol SNMP manageable series of modules The 3 Slot Desktop Chassis is a 1U high a Rackmountable capable of offering redundant power supply modules and supports a SNMP Management Module 3 Slot Desktop Chassis Features The 3 Slot Desktop Chassis series offers a line of models including single AC single DC dual AC dual DC and ACDC version All contain internal fixed power supply modules that are not end user replaceable It offers features such as redundant power supply modules temperature monitoring Last Gasp and an Alarm Reset Button A rie A ENT AT A FE Fe B L Ei
13. a SNMP on any previous Management ds _ pete Modules Leave this switch in the NORMAL position during day to day operation the LOCKED position should only be used when changing the SNMP management board The SNMP Management Module can be removed and replaced as necessary Refer to the SNMP Management Module manual for complete instructions about configuration and operation If an SNMP Management Module is installed refer to the LED panel below for indicators of Link Temperature Power Supply modules and other functions SNMP Management Module LEDs The SNMP Management Module features several LEDs The LED functions are 12 LNK ACT Glows green when a link is established on port a i ement Blinks green when data activity occurs Glows yellow when port is in Full Duplex mode din Blinks yellow when port is operating in Half Duplex mode and collisions occur TEMP Glows yellow when temperature of unit surpasses a user defined level PS Glows yellow when one power supply module malfunctions FAN A FAN B Glows yellow when a fan malfunctions Installing the 6 Slot Rackmount Desktop Chassis Install the chassis first before installing any modules into a 6 Slot Rackmount Desktop Chassis When installing the chassis be sure to observe the following precautions to prevent electrical or mechanical damage 1 Protect the chassis from exposure to sunlight and electrical or magnetic fields 2 Ensure that the equip
14. aparato el ctrico no deber ser usado cerca del agua por ejemplo cerca de la tina de ba o lavabo s tano mojado o cerca de una alberca etc El aparato el ctrico debe ser usado nicamente con carritos o pedestales que sean recomendados por el fabricante El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las instrucciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado El aparato el ctrico debe ser situado de tal manera que su posici n no interfiera su uso La colocaci n del aparato el ctrico sobre una cama sof alfombra o superficie similar puede bloquear la ventilaci n No se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilaci n El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 12 13 14 15 16 re 18 El aparato el ctrico deber ser conectado a una fuente de poder s lo del tipo descrito en el instructivo de operaci n o como se indique en el aparato Precauci n debe ser tomada de tal manera que la tierra f sica y la polarizaci n del equipo no sea eliminada Los cables de la fuente de poder deben ser guiados de
15. arts can be replaced without having to send an entire unit in for repair User Replaceable Power Supply Modules Reset Alarm Button When one power supply module malfunctions an audible alarm sounds indicating the loss of the power module The alarm can be silenced by pressing the Alarm Reset Button located next to the power connector on the power supply module If this occurs remove and replace the power supply module immediately LEDs on the Management Module and the power supply module itself also indicate power supply module failures Last Gasp Alarm The 20 Slot Rackmount Chassis includes the Last Gasp trap feature Remote Chassis Down which sends a Trap when the following occurs e Both power supply modules malfunction e Both power supply modules are powered down When the AC line fails Temperature Gauge The 20 Slot Rackmount Chassis includes a temperature monitoring gauge with a heat sensor on the backplane of the chassis Users define a threshold for chassis temperature via SNMP If the chassis temperature rises above the specified level the SNMP agent sends a trap configured in iView2 to the administrator There is also an LED indicator on the SNMP Management Module for chassis temperature SNMP Write Lock There is an SNMP Write Lock switch located below slot 3 on the front of the 20 Slot Rackmount Chassis The SNMP Write Lock switch prevents a new management board from re configuring the applicat
16. bol indicates that the equipment should be disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information about proper disposal please contact local authorities waste disposal services or the point of purchase for this equipment 25 Black Box Tech Support FREE Live 24 7 Tech support the way it should be Great tech support is just 20 seconds away at 724 746 5500 or www blackbox com BLACK BOX About Black Box Black Box Network Services is your source for more than 118 000 networking and infrastructure products You ll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 20 seconds or less yright 2010 Black Box Corporation All rights reserved 50 80054BB 00 A2 124 746 5500 www blackbox com
17. cautions Electrostatic discharge ESD can cause damage to any product add in modules or stand alone units containing electronic components Always observe the following precautions when installing or handling these kinds of products 1 Do not remove unit from its protective packaging until ready to install 2 Wear an ESD wrist grounding strap before handling any module or component If the wrist strap is not available maintain grounded contact with the system unit throughout any procedure requiring ESD protection 3 Hold the units by the edges do not touch the electronic components or gold connectors 4 After removal always place the boards on a grounded static free surface ESD pad or in a proper ESD bag Do not slide the modules or stand alone units over any surface WARNING Integrated circuits and fiber optic components are extremely susceptible to electrostatic discharge damage Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices Certifications UL CUL Listed to Safety of Information Technology Equipment including Electrical Business Equipment CE Class 1 Laser product Luokan 1 Laserlaite Laser Klasse 1 Appareil A Laser de Classe 1 European Directive 2002 96 EC WEEE requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste This sym
18. ccccccssccssscessecessecessecesesesseecsseeesesenes 1 Back Up Spares Sold Separately oooooooooccococoncconcconnoranocinaconconanoso 1 3 Slot Desktop Chassis oooooooccocccocncnonoconoconaconnconnconnnonn coca noconocnnn crono cora cnnacono 2 Back Up Spares Sold Separately oooooooooococononcconccnanoranocincconnornnoss 2 About the 20 Slot Rackmount Chassis ooccccccnnccnnoooccnnnnnnnnnnanoconnnnnnnnanos 3 20 Slot Rackmount Chassis Features 3 Alarm Reset Last Gasp and Temperature Gauge coccooncconcconccinnccnnonnnos 3 Reset Alarm Button reset 4 Last Gasp A Mirate tee 4 Temperalure US emisiones ceic TO 4 SNMP Write Lock snert snert 4 SNMP Management Module LEDS ooooooocoocconcononononocinccionoranannos 4 Installing the 20 Slot Rackmount Chassis oooooocooccconcconoconcconocanonnnonnnso 5 Wiring Instruction Guidelines for DC Module in 2DC and ACDC 6 DC Power Supply Module Wiring Instructions oooooooooncconcrnncnnos 6 Installing SNMP Management and Application Modules 7 Replacing Power Supply Modules ooooooocococcconcconnccnnocanocanacinac nnoranoss 8 User Replaceable Power Supply Modules oooooooccconcconcconconncnnoso 8 Dual AC Part Number LMC5207A R2 seres 8 Dual DC Part Number LMC52O8ARR2 0000 rr 9 ACDC Part Number L
19. dules To install a module 1 Remove the blank bracket if present covering the slot where the module will be installed Black Box recommends installing blank brackets in unused module slots 2 Slide the module into the chassis using the card guides 3 Secure the module to the chassis by tightening the captive screw Refer to the documentation shipped wath the module for configuration information 4 When installing modules observe ESD precautions refer to the Electrostatic Discharge Precautions section In order to manage a 20 Slot Rackmount Chassis the SNMP Management Module needs to be installed in the appropriate slot of the chassis Install the 20 Slot Rackmount Chassis SNMP Management Module into the first slot of the chassis This slot is ONLY for the Management Module do not install Application Modules such as media conversion and mode conversion modules in this slot Ei e High Density 20 Siot Media Converter System im AE Sni Replacing Power Supply Modules User Replaceable Power Supply Modules While power supply modules are redundant failed power supply modules should promptly be replaced to maintain network integrity and prevent data loss To replace a power supply module 1 2 3 Disconnect the power source from the power supply module Remove the screws of the retainer plate on some AC modules Move the Power Supply Release switch toward the right or unscrew captive re
20. ent should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips 9 All AC and DC versions are intended for use in a Restricted Access Location RAL DC Power Wiring Replacing Power Supply and Fans DC Power Supply Wiring Instructions The following diagram shows the wiring configurations for 48 VDC power supply for the 6 Slot Rackmount or Desktop DC Power Supply DC Power Supply lf in a 48 environment If in a 48 environment Terminal Block Terminal Block GND Chassis GND 3 Chassis GND common 48 GND common User Replaceable Power Supplies The 6 Slot Rackmount Desktop Chassis ships from Black Box with one or two power supply installed depending on the model Chassis ordered with one power supply come with a filler tray installed in the second slot To install a second power supply 1 Remove the filler tray 2 Slide the power supply module into the chassis and click into place 3 Attach power cord To remove a power supply module 1 Disconnect the power source from the power supply 2 Move the Power Supply Release switch toward the right and hold while grasping the power supply module by the silver handle 3 Slide out of the chassis Power supply modules are hot swappable 4 Install new power supply module Fans Users can define a threshold for fan operation via SNMP when installed in a
21. erature Dual AC amp ACDC 20 C to 80 C 4 F to 176 F Dual DC 20 Cto 60 C 4 F to 140 F Humidity 20 to 90 non condensing at 40 C Shipping Weight 25 lbs 11 3 kg Dimensions 5 2 x 19 0 x 13 8 13 21cm x 48 26cm x 35 05cm 10 About the 6 Slot Rackmount Desktop Chassis The 6 Slot Rackmount Desktop Chassis is a modular chassis platform designed for use with Black Box Simple Network Management Protocol SNMP manageable series of modules The 6 Slot Rackmount Desktop Chassis is 1U high Rackmountable and supports optional redundant power supply modules as well as an SNMP Management Module 6 Slot Rackmount Desktop Chassis Features The 6 Slot Rackmount Desktop Chassis offers a line of models including single AC single DC dual AC and Dual DC It offers features such as redundant power supply modules temperature monitoring Last Gasp and an Alarm Reset Button Power Supply a Module 1 PS1 P f Power Supply AC Power Power Supply Module 2 PS2 Status LED Connector Alarm Reset Last Gasp and Temperature Gauge The 6 Slot Rackmount Desktop Chassis supports modular power supply modules so that worn parts can be replaced without having to send an entire unit in for repair Keeping fans functional ensures that the modules will operate within their temperature specifications Alarm Reset Button When one power supply module malfunctions an audible alarm sounds indicating the l
22. ion module settings e g the 5 status of features such as LinkLoss FiberAlert Force mode etc made via SNMP on any previous Management Modules Coua ERSS y P 5 Leave this switch in the NORMAL position during day to day operation the LOCKED position should only be used when changing the SNMP management board The SNMP Management Module can be removed and replaced as necessary Refer to the SNMP Management Module manual for complete instructions about configuration and operation If an SNMP Management Module is installed refer to the LED panel below for indicators of Link Temperature Power supply modules and other functions SNMP Management Module LED The SNMP Management Module features several LEDs The LED functions are LNK ACT Glows green when a link is established on port Blinks green when data activity occurs Ei Glows yellow when port is in Full Duplex mode Blinks yellow when port is operating in Half Duplex mode and collisions occur FDX COL TEMP Glows yellow when temperature of unit surpasses a user defined level PS Glows yellow when one module malfunctions FAN A FAN B Glows yellow when a fan malfunctions Installing the 20 Slot Rackmount Chassis Install the chassis first before installing any modules into a 20 Slot Rackmount Chassis When installing the chassis be sure to observe the following precautions to prevent electrical or mechanical damage 1 Protect the chassis from ex
23. lease screw Before grasping the power supply module by the silver handle press the release screw and then slide out of the chassis Power supply modules are hot swappable Install new power supply module If module is equipped with an ON OFF switch install the module with the switch in the OFF position Dual AC Part Number LMC5207A R2 PS Release Screw Power Supply Power Supply Module 1 Status LED PS1 y Reset Alarm Switch Power Connector Module 2 PS2 Dual DC Part Number LMC5208A R2 Power Supply PS Release eas ER Lever z Reset Alarm Switch Power Supply ON OFF Module 1 Switch PS1 Power Connector Power Supply ee le 2 Redundant DC Power Supply Close Up NOTE Do not mix AC and DC power supply modules ACDC Part Number LMC5228A PS1 Status LED Reset PS Alarm Release Switch Screw Power Supply DC Power Module Connector ae a PS2 des Supply Module 2 PS2 AC Power Connector Redundant ACDC Power Supply Close Up For LMC5228A 20 Slot Rackmount Chassis all models in that model number series can support Dual AC Dual DC or ACDC The power supply modules for that model number series are interchangeable 20 Slot Rackmount Chassis Specifications Input Specifications Dual AC 100 to 240V AC 50 60Hz 3 5 1 5A Dual DC 48V DC 5A ACDC 100 to 240V AC 50 60HZ 2A 48V DC 4 4A Operating Temperature 0 C to 50 C 32 F to 122 F Storage Temp
24. managed environment Ifa fan s speed falls below the specified level SNMP sends a trap configured 14 in View2 to the administrator There are also two LED indicators on the SNMP Management Module for fan failure The red Alarm Reset Button also functions as a Fan Test button To verify fan functionality hold the button down for several seconds the fans should engage The fans will turn off when the button is released SNMP Management Modules include two twisted pair ports one for management and one reserved for future use The Management Module also features a DB 9 serial port and supports SNMP V1 V2c Installing Management and Application Modules Installing Applications Modules To install a module 1 Remove the blank bracket if present covering the slot where the module will be installed Black Box recommends installing blank brackets in unused module slots 2 Slide the module into the chassis using the card guides 3 Secure the module to the chassis by tightening the captive screw Refer to the documentation shipped with the module for configuration information 4 When installing modules observe ESD precautions refer to the Electrostatic Discharge Precautions section In order to manage a 6 Slot Rackmount Desktop Chassis the SNMP Management Module needs to be installed in the appropriate slot of the chassis e Install the 6 Slot Rackmount Desktop Chassis into the first slot on the far left of the chassis
25. ment rack remains stable even with the addition of the chassis and its associated cabling To install a 6 Slot Rackmount Desktop Chassis 1 Have four 10 screws and four clip nuts available hardware may vary depending on rack type The rest of the hardware is supplied with the unit 2 Locate a suitable location in the rack for installation and secure the clip nuts onto the mounting rails Use screws to attach the chassis to the rack are the chassis into a reliable filtered power source 4 Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer 5 Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised 6 Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading 7 Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring 13 8 Reliable Grounding Reliable grounding of Rackmounted equipm
26. nt or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult an experienced radio TV technician for help CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment To meet FCC requirements shielded cables and power cords are required to connect this device to a personal computer or other Class B certified device This digital apparatus does not exceed the Class B limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada Product Description Version a A Fra B Dual AC 20 Slot Rackmount Chassis Dual DC 6 Slot Rackmount Desktop Chassis L AC 3 Slot Desktop Chassis A DC La AAA Do l E 2 ee DualDC a a i a Ss Normas Oficiales Mexicanas NOM Electrical Safety Statement Instrucciones de Seguridad 1 10 Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que el aparato el ctrico sea operado Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura Todas las advertencias en el aparato el ctrico y en sus instrucciones de operaci n deben ser respetadas Todas las instrucciones de operaci n y uso deben ser seguidas El
27. op Chassis Install the chassis first before installing any modules into a 3 Slot Desktop Chassis When installing the chassis be sure to observe the following precautions to prevent electrical or mechanical damage 1 Stay within the chassis power rating to prevent overload of supply circuits or damage to any overcurrent protection and supply wiring 2 Maintain reliable ground especially when connecting to a power strip instead of directly to a branch circuit 3 Protect the chassis from exposure to sunlight and electrical or magnetic fields 4 Ensure that the equipment rack remains stable even with the addition of the chassis and its associated cabling Use the 3 Slot Desktop Chassis as a table top chassis mount in a Rackmount shelf or mount it to a wall surface 1 Install the 3 Slot Desktop Chassis by placing it on a flat surface 2 Make sure to leave adequate space on the sides of the unit to accommodate cooling 3 If mounting on a Rackmount shelf align holes of the chassis to the shelf and secure with screws The Rackmount shelf is sold separately To purchase the Rackmount shelf part number LMC5238 visit the Black Box Product Accessories page htto www blackbox com Store Results aspx search LMC5238 5e 5e 5e p 0 Rackmounting requires a Rackmount shelf for mounting up to two units side by side 4 Attach the cables between the chassis and the device that will be interconnected and then plug the unit into
28. oss of the power supply module The alarm can be silenced by pressing the Alarm Reset Button located next to the power connector on the power supply module If this occurs remove and replace the power supply module immediately LEDs on the Management Module and the power supply itself also indicate power supply failures After stopping the alarm remove the power supply and replace the power supply module Last Gasp Alarm The 6 Slot Rackmount Desktop Chassis includes the Last Gasp trap feature Remote Chassis Down which sends a Trap when the following occurs 11 Both power supply modules malfunction Both power supply modules are powered down e When the AC line fails Temperature Gauge The 6 Slot Rackmount Desktop Chassis includes a temperature monitoring gauge with a heat sensor on the backplane of the chassis Users define a threshold for chassis temperature via SNMP If the chassis temperature rises above the specified level the SNMP agent sends a trap configured in iView to the administrator There is also an LED indicator on the SNMP Management Module for chassis temperature SNMP Write Lock There is an SNMP Write Lock switch located above the SNMP module slot on the front of the 6 Slot Rackmount Desktop Chassis The SNMP Write Lock switch prevents a new management board from re configuring the application module settings e g the status of features such as LinkLoss FiberAlert Force mode etc made vi
29. posure to sunlight and electrical or magnetic fields 2 Ensure that the equipment rack remains stable even with the addition of the chassis and its associated cabling To install 20 Slot Rackmount chassis 1 Have four 10 screws and four clip nuts available hardware may vary depending on rack type The rest of the hardware is supplied with the unit 2 Locate a suitable location in the rack for installation and secure the clip nuts onto the mounting rails Use screws to attach the chassis to the rack 3 Plug the chassis into a reliable filtered power source 4 Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the Black Box 5 Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised 6 Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading 5 9 Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wi
30. ring Reliable Grounding Reliable grounding of Rackmounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips All AC and DC versions are intended for use in a Restricted Access Location RAL Wiring Instan Guidelines for DC Module in 2DC and ACDC 1 Connection of a suitable grounding conductor to the grounding terminal at each power supply module a minimum 14AWG copper conductor should be suitable on a 15A circuit breaker requirement Connection of suitable supply wiring to the plus and minus terminals at each power supply module a minimum 14AWG copper conductors is considered suitable based on the 11A input maximum The input terminal block at the power supply module is suitable for 22 14 AWG copper wire A suitable listed circuit breaker shall be provided in the building installation as the unit s disconnect device The branch circuit rating i e minimum 15A listed circuit breaker etc DC Power Supply Module Wiring Instructions The following diagram shows the wiring configuration for a 48 VDC power supply module for the 20 Slot Rackmount Chassis 2DC and ACDC Chassis Ground Return 1 48 VDC I The chassis is protected against incorrect wiring configurations When wired incorrectly the chassis will not function but no damage will occur Installing SNMP Management and Application Mo
31. t with Isolated Grounding Plane practices The POSITIVE and NEGATIVE terminals are isolated from chassis ground and must have a ground reference at the power sourcing equipment Power Supply Modules Power supply in all models of the 3 Slot Desktop Chassis are fixed and not end user replaceable 19 Fans The 3 Slot Desktop Chassis includes temperature triggered fans When the temperature of the chassis reaches 40 C the two fans activate to cool the chassis The fans operation can be tested by holding the Alarm Reset Button down for 4 to 5 seconds The fans will activate and then they will turn off when the button is released If the fans do not activate contact Black Box Fans are not end user replaceable The red Alarm Reset Button also functions as a Fan Test button To verify fan functionality hold the button down for several seconds the fans should engage The fans will turn off when the button is released Installing Management and Application Modules SNMP Management Modules include two twisted pair ports one for management and one reserved for future use The Management Module also features a DB 9 serial port and supports SNMP V1 V2c Installing Applications Modules To install a module 1 Remove the blank bracket if present covering the slot where the module will be installed Black Box recommends installing blank brackets in unused module slots 2 Slide the module into the chassis using the card guides 3