Belkin F6H500-SER User's Manual

image

Contents

1. Diagram 1 UPS Outlets See 1 on Diagram 1 These outlets are your battery back up outlets We strongly recommend that only sensitive equipment such as your computer and monitor should be plugged into these outlets Never plug in any printer Should a power outage occur your battery backup will automatically turn on Power utility or battery is not supplied to these outlets when the UPS is switched off Please do not plug any surge protectors or power strips into the battery back up outlets i e daisy chaining SURGE Protected outlets See 2 on Diagram 1 These outlets do not provide power during a power outage Equipment such as computer peripherals printers fax machine s or a desk lamp may be plugged into these outlets These outlets are not controlled by the On Off button The On Off button has 3 functions 1 Turns on the UPS Depress button at least 2 seconds The green light will come on 2 Cold Start function Assuming the battery is charged the UPS will work without it being plugged into an outlet Depress and hold the key for at least 2 seconds to turn on the UPS The 3 Silence function During On Battery Mode the audible sound can be turned ON or OFF by depressing the switch Side Panel A AC Input Circuit Breake
2. CIFICATIONS MODEL F6H500 USB RATED CAPACITY 500VA 300W RATED INPUT VOLTAGE 105 135Vac PHASE FREQUENCY Single phase 60HZ VOLTAGE OUTPUT FREQUENCY 60HZ 1HZ BACKUP Desktop computer 17 monitor TIME Aa BATTERY m RECHARGE TIME lt 8hours to 90 TEMPERATU ENVIRONMEN 0 35 C T HUMIDITY 10 90 SAFETY UL1778 C UL SAFETY REGULATION FCC CLASS B IEEE C62 41 CATEGORY A DIMENSION 3 14 X 9 84 X 6 6 inches APPEARANCE NET WEIGHT j All specifications are subject to change without prior notice TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION On Off button not Press the On Off pushed or pushed button more than 2 less than 1 second second Battery voltage Recharge the UPS at less than 10V least 5 hours Contact service Re plug the power LED is not lit UPS is not on AC breaker is tripped Reset the breaker UPS always __sat battery mode Power disturbances have Normal operations occurred Battery is not fully Recharge the UPS at charged least 6 hours Back up time too Remove Charger fault or Contact service other reason personnel STORAGE Storage Conditions Store the UPS covered and upright in a cool dry location with its battery fully charged Before storing charge the UPS for at least 6 hours Extended Storage During extended storage in environments where the ambient temperature is 5 F to 86 F charge the UPS battery every 6 months During extended storage in
3. F6H350 SER F6H500 SER F6H650 SER F6H500 USB USER MANUAL INTRODUCTION Thank you for purchasing a Belkin Uninterruptible Power Supply UPS Each year several natural and man made occurrences put the power supplied to your work stations in your home or office in jeopardy At risk is your hardware software and data because of these power problems IMPORTANT Please save this manual It contains important operating instructions and warranty information pertaining to your UPS Please save or recycle the packaging materials The UPS packaging was designed to provide protection during shipment and delivery This packaging can be reused should you have return the UPS for service Damage sustained during transit is not covered under the warranty Federal Communications Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications To assure continued compliance use only shielded interface cables when connecting to computer or peripheral devices Any changes or modifications not expressly approved by the party responsible
4. ay need charging Should the red site wiring fault light come on Please refer to the UPS Features and Functions Chart 1 for the proper reference Site Wiring Light 3 Turn off the UPS before installing any products into the UPS or Surge outlets Please be sure all equipment to be installed into any of the outlets is turned off This will ensure that a power disturbance will not affect your equipment 4 Plug in only one computer and monitor into the UPS outlets We strongly recommend that only this equipment be plugged into the UPS outlets For all other equipment plug into the Surge outlets 5 Plug one end of the phone cable you received into your telephone jack and plug the other end into the jack marked IN You may now plug a phone fax or modem into the two jacks marked OUT See Diagram 3 Modem To Telephone Socket Fax Diagram 4 6 Optional To full utilize the Sentry Bulldog Shutdown Software you will need to connect the UPS to your computer Connect the RJ45 jack to your UPS then connect the serial end to the serial port on your computer SOFTWARE INSTALLATION Optional 1 Your UPS features the Sentry Bulldog Shutdown Software This allows protects and saves your data should a power outage occur N To install the software please place the CD into the CD player of your computer 3 Your computer should automatically run the CD If this does not o
5. ccur goto the Run feature on your Start icon lower left corner on your screen Please enter the CD drive it may be D Should you continue to have a problem please refer to your computer s owner s manual for the correct drive 4 Once uploaded please click the Bulldog icon on the screen 5 Click Install Belkin Sentry Bulldog for Win 95 98 ME NT4 2000 XP 6 InstallShield Wizard will appear onscreen click Next 7 Please read the License Agreement and click Yes 8 On Setup Type click ALL Standalone You should not install the networking files unless you technically qualified to use these features 9 On Choose Destination click Next 10 On Select Program Folder click Next 11 On Setup Type please choose your language choice 12 The software will now upload Once completed please click Finish 13 Please click the appropriate user s manual to download 14 Click X on the Bulldog setup screen to leave the software setup 15 Please refer to the user s manual for software setup and information on software features Uninstall for Windows 95 98 Me NT4 2000 XP There are two options to uninstall the Sentry Belkin Shutdown Software 1 Select the Setup from the BELKIN SENTRY BULLDOG program folder and select the remove option to begin the uninstall procedure 2 Select Add Remove Programs from the Control Panel and click on the BELKIN SENTRY BULLDOG item then press the Add Remove button TECHNICAL SPE
6. environments where the ambient temperature is 86 F to 113 F charge the UPS battery every 3 months Note x E i S pa Away from water Away from sunlight Away from heat BELKIN COMPONENTS USER LICENSE AGREEMENT Belkin Components Belkin thanks you for choosing one of our products for your use This User License Agreement Agreement contains the terms and conditions under which limited use of the product is licensed to you PLEASE READ THIS NOTICE CAREFULLY DO NOT OPEN THIS ENVELOPE OR USE ANY OF THE SOFTWARE UNTIL YOU HAVE READ AND AGREED TO THIS AGREEMENT IF YOU OPEN THE ENVELOPE YOU ARE AGREEING TO THE TERMS AND CONDITIONS SET OUT IN THIS AGREEMENT IF YOU DO NOT ACCEPT THESE TERMS AND CONDITIONS YOU MUST RETURN THE ENVELOPE UNOPENED AND WITH THE DISKS INSIDE TO THE PARTY FROM WHOM YOU RECEIVED IT SCOPE OF USE In this Agreement software means all machine readable software programs and associated files in this package All modified versions of and upgrades or improvements to such programs and all copies of such programs and files You a single user opening this envelope You or our may use the software on a single central processing unit You may not rent it loan it out or lease it nor use it on a multi user system LICENSE You have the non exclusive right to use the software You are not permitted to copy modify or transfer the software or documentation You may not compile disassemble
7. for compliance could void the user s authority to operate this equipment CONTENTS You should have received the following 1 UPS unit 1 Sentry Bulldog Shutdown Software 1 Serial Cable 1 USB Cable 1 Phone Line Cable UPS FEATURES AND FUNCTIONS Before installation please inspect the UPS upon receipt Make sure that nothing is damaged Your UPS features 3 LED indicators Each is marked by a power icon please familiarize yourself with this chart as it will assist you in the use of your UPS Draka ON LINE O Solid green AC power is on The On Battery and Low Battery LED can indicate 1 of 3 conditions 1 The UPS is on battery CAJ backup if the green light is off and an intermittent audible alarm is on The UPS will begin ON BATTERY shutdown procedure and LOW BAT TERY xt Flashing Red Battery is low The UPS will start shutdown The buzzer sounds an audible alarm There is a problem with the UPS The LED will be lit continuously and the buzzer will sound audible alarm for 10 SEC The Site Wiring fault LED can indicate 1 of 2 possible conditions 1 Open or high resistance SITE WIRING ground FAULT 2 Hot or neutral polarity circuit O Solid Red Chart 1 Front Panel
8. mitation of implied warranties or of liability for incidental damages so the foregoing limitations or exclusion may not apply to you This warranty gives you specific legal rights which vary from jurisdiction to jurisdiction HOWEVER YOU WAIVE SUCH RIGHTS EXCEPT AS EXPRESSLY PROVIDED UNDER THE TERMS AND CONDITIONS OF THIS AGREEMENT TO THE MAXIMUM EXTENT ALLOWED BY LAW The license is governed by the laws prevailing in the State of New York without regard to its conflicts of laws principles ACKNOWLEDGMENT By opening the package on which this Agreement is printed or through which it is visible you acknowledge that you have read this Agreement understand it and agree that this agreement is the complete and exclusive statement of agreement between yourself and Belkin and supersedes any prior agreements oral or written and any other communications relating to the subject matter of this Agreement SEVERABILITY Any term or provision of this Agreement or any application thereof which may be prohibited or unenforceable by law in a particular jurisdiction shall be interpreted and enforced to the maximum extent allowed in such jurisdiction which the parties acknowledge could mean severing the provision from this Agreement or if allowed enforcing it in a narrower form without affecting the remainder of this Agreement or any other application of such term or provision in such jurisdiction or application of such term or provision in an
9. or otherwise reverse engineer break down analyze or modify the software USE AND RESTRICTIONS You are permitted to make backup copies of all the software disks for archival purposes only You must reproduce the proprietary notice set forth on the disks and affix them to all backup copies You are not permitted to use these programs in connection with a computer service or to use the backup copies other than as a replacement for the original copy TERM This license is effective upon acceptance by opening this envelope or in any other way using the enclosed software which will constitute your acceptance of and agreement to this Agreement and is effective until terminated The limited license in this Agreement will be automatically terminated if you fail to comply with any of the Terms and conditions in this Agreement You agree that upon such termination you will immediately destroy all programs and documentation including all copies made or obtained by you SOFTWARE PROGRAM DOCUMENTATION AND ANY RELATED INFORMATION GOODS OR SERVICES ARE PROVIDED WITH NO WARRANTY OR REPRESENTATION OF ANY KIND WHAT SO EVER BELKIN HEREBY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The entire risk of the use results and performance of the software program and documentation is borne by you Should any or all of the product software prog
10. r Push to Reset OUT H Phone Fax Modem OUT Protection a IN Refer to Bottom for Cautionary Markings Diagram 2 AC Input Power Cord See 1 on Diagram 2 Provides power to your UPS Phone Fax Modem Surge Protection See 2 on Diagram 2 The Phone Fax Modem lines are surge protected There is one input jack and two output jacks AC Breaker Circuit Breaker See 3 on Diagram 2 Should a power overload occur the circuit breaker will trigger the UPS to turn off AC power Side Panel B Serial Communication Port Diagram 3 Your UPS features a serial communication port Installation of the cable and software is optional This allows the UPS to connect to you computer The Sentry Bulldog Software will not work if the UPS is not connected to you computer This does not mean the battery backup feature will not work without the software and cable installed The UPS will still provide backup power but you will be unable to utilize the data management capabilities of the software UPS INSTALLATION Please plug in your UPS without any equipment plugged in Turn on your UPS by depressing the On Off button for approximately 2 seconds You will see the green indicator light come on We recommend you charge the battery for at least 8 hours prior to full use The battery will not charge unless the UPS is turned on Battery Light Should you see the red battery light come on the battery m
11. ram documentation or related information goods or services be defective misused unsuitable or Cause or give rise to any harm or liability whatsoever you not Belkin or its associates dealers or agents assume the entire liability cost of repair correction or any payment or other remedy whatsoever Furthermore no warranty or guarantee is made regarding the use or results of the product software program documentation or any related information goods or services in terms of correctness accuracy reliability timeliness or otherwise You use and rely on the program at your own risk The following is the only and exclusive warranty and remedy of any kind Belkin does warrant that the program disks are free from physical defects in materials and workmanship under normal use for a period of one 1 year from the date of purchase as evidenced by a copy of the sales receipt Return the defective disk or documentation with your receipt directly to Belkin for a replacement DISCLAIMER Belkin or its associates will in no event be liable i in any amount for lost profits or special incidental punitive or consequential damages or ii for any claim or damage of any nature or under any theory whatsoever in any amount in excess of the purchase price you paid for the product The warranties and remedies here set forth are exclusive and in lieu of all others oral or written express or implied Some jurisdictions do not allow exclusion or li
12. y other jurisdiction SAFETY INFORMATION CAUTION e Internal battery voltage is 12V DC e The unit is intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants All batteries used are Sealed Lead Batteries Batteries must be recycled Recycling Information Your UPS contains a Non spill Sealed Lead Battery On the battery you will find the battery name Please reference the chart below for recycling information Battery Name Recycling Inside the Recycling USA Outside the USA BB Battery 800 278 8599 1 817 244 4415 CSB Battery 800 738 7372 VISION Battery 973 726 5323 CONTACT US Belkin Components Ltd 501 West Walnut St Compton CA 90220 5221 USA Tel 310 898 1100 Fax 310 898 1111 Belkin Components Ltd Unit 13 Gatelodge Close Round Spinney Northampton NN3 8RX UK Tel 44 0 1604678300 Fax 44 0 1604678330 Belkin Components B V Starparc Building Boeing Avenue 333 1119 PH Schiphol Rijk The Netherlands Tel 31 0 20 654 73 00 Fax 31 0 20 654 73 49 Belkin Australia Ltd 7 Bowen Cresent West Gosford NSW 2250 Tel 61 02 4325 4666 Fax 61 02 4325 4277