Home

Behringer C-3 User's Manual

image

Contents

1. 20 50 100 200 500 1000 2000 5000 10000 20000 Hz Cardioid Low Cut Figure3 10 dB Omni NG Frequency response 7 STUDIO CONDENSER MICROPHONE G3 User Manual 7 Specifications Transducer type condenser 16 mm Polar pattern cardioid figure 8 omni Connection gold plated balanced XLR connector Open circuit sensitivity 40 dBV pa 10 mV pa Frequency response 40 Hz 18 kHz Max SPL lt 0 5 THD 1 kHz 142 dB Equivalent noise level 23 dBA IEC 651 Dynamic range 119 dB Rated Impedance 3500 Supply voltage 48V Supply current 7 0mA Dimensions shaft 54 mm length 180 mm Weight 0 42 kg BEHRINGER is constantly striving to maintain the highest professional standards As result of these efforts modifications may be made from time to time to existing products without prior notice Specifications and appearance may differ from those listed or illustrated We Hear You AN behringer com behringer
2. STUDIO CONDENSER MICROPHONE Dual Diaphragm Studio Condenser Microphone AN behringer 2 STUDIO CONDENSER MICROPHONE G3 User Manual EN Important Safety Instructions CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE D LECTROCUTION NE PAS OUVRIR Terminals marked with this symbol carry electrical current of sufficient magnitude to constitute risk of electric shock Use only high quality commercially available speaker cables with 7 TS plugs pre installed All other installation or modification should be performed only by qualified personnel This symbol wherever it appears alerts you to the presence of uninsulated dangerous voltage inside the enclosure voltage that may be sufficient to constitute a risk of shock This symbol wherever it appears alerts you to important operating and maintenance instructions in the accompanying literature Please read the manual Condenser microphones are extremely moisture sensitive Never use your microphone in close proximity to water e g bath tubs wash basins sinks washing machines pools etc When doing voice recordings always use the enclosed windscreen to protect the capsule from moisture Always use the power supply specified in the operating instructions Take care not to drop AN your microphone as this can lead to severe damage BEHRINGER assumes no liability for any damage caused by the user After each use
3. a balanced XLR microphone cable with the following pin assignment pin 1 shielding 2 3 Since your features gold plated contact points throughout we recommend that you use only microphone cables with gold plated connectors 6 Level Setting Adjusting the Basic Sound Adjust the gain control in the microphone channel of your mixing console so that the peak LED lights up only occasionally or never at all The EQ controls in the microphone channel should be set to mid travel position to start with low cut filter and signal level attenunation should be switched off To get the sound you want try changing the mic position relative to the sound source or even move the microphone around in the recording room of your studio Adjusting the angle at which walls face the sound source can also be helpful Only when the desired basic sound has been achieved should you start to use equalizers and signal processors if any at all remember less is often more Due to the extremely linear frequency response and the high sonic resolution of your C3 there is no need for high frequency EQing that can heavily influence the signal and unnecessarily increase the noise level The C3 provides that much desired transparency which often gets lost during recording and mixing 6 STUDIO CONDENSER MICROPHONE G3 User Manual N o Super Cardioid Figure 8 Omni 2 Polar pattern
4. wipe the microphone down with a soft cloth and place it back into its protective casing included with the microphone Then lay the small bag containing the moisture absorbing crystals on top of the microphone head LIMITED WARRANTY For the applicable warranty terms and conditions and additional information regarding MUSIC Group s Limited Warranty please see complete details online at www music group com warranty LEGAL DISCLAIMER TECHNICAL SPECIFICATIONS AND APPEARANCES ARE SUBJECT TO CHANGE WITHOUT NOTICE AND ACCURACY IS NOT GUARANTEED BEHRINGER KLARK TEKNIK MIDAS BUGERA AND TURBOSOUND ARE PART OF THE MUSIC GROUP MUSIC GROUP COM ALL TRADEMARKS ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS MUSIC GROUP ACCEPTS NO LIABILITY FOR ANY LOSS WHICH MAY BE SUFFERED BY ANY PERSON WHO RELIES EITHER WHOLLY OR IN PART UPON ANY DESCRIPTION PHOTOGRAPH OR STATEMENT CONTAINED HEREIN COLORS AND SPECIFICATIONS MAY VARY FROM ACTUAL PRODUCT MUSIC GROUP PRODUCTS ARE SOLD THROUGH AUTHORIZED FULLFILLERS AND RESELLERS ONLY FULLFILLERS AND RESELLERS ARE NOT AGENTS OF MUSIC GROUP AND HAVE ABSOLUTELY NO AUTHORITY TO BIND MUSIC GROUP BY ANY EXPRESS OR IMPLIED UNDERTAKING OR REPRESENTATION THIS MANUAL IS COPYRIGHTED NO PART OF THIS MANUAL MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM OR BY ANY MEANS ELECTRONIC OR MECHANICAL INCLUDING PHOTOCOPYING AND RECORDING OF ANY KIND FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN PERMISSION OF
5. MUSIC GROUP IP LTD ALL RIGHTS RESERVED 2013 MUSIC Group IP Ltd Trident Chambers Wickhams Cay P 0 Box 146 Road Town Tortola British Virgin Islands 3 STUDIO CONDENSER MICROPHONE G3 User Manual 1 Power Supply Your condenser mic needs a phantom power supply 48 If your is connected to a microphone preamp and supplied with phantom power the LED on the microphone lights up BEHRINGER assumes no liability for any damage caused by a defective phantom power supply Always mute the sound reinforcement system before you switch on the phantom power supply 2 Directivity Your is large diaphragm microphone featuring a double membrane This allows you to choose between three different pickup patterns cardioid omnidirectional and figure eight Make your selection using the switch located at the back of your microphone 2 1 Cardioid Microphones with this polar pattern switch position middle are most sensitive to sound coming from in front of the microphone and also to lesser extent from the sides Sound coming from behind the microphone will be greatly attenuated This makes the cardioid polar pattern most suitable for recording individual instruments or vocals within a group 2 2 Figure eight Microphones featuring the figure eight polar pattern switch position left 8 are most sensitive to sound coming from either directly in front of or directly behind the microphone So
6. particularly recommended when recording impulse sound sources with high sound pressure e g a bass drum 4 Microphone Installation Fig 4 1 Attaching the microphone stand A holder is screwed onto your microphone allowing you to attach it to mic stands with a34 thread An adapter has been included First dismantle the microphone from the stand mount adapter 2 by detaching the fine thread shoulder screw at the bottom end of the microphone Fasten the adapter onto the microphone stand place the microphone into it and tighten the screw again Basically the microphone in the stand mount adapter should stand upright and face the sound source at a right angle The angle of the microphone to the sound source influences the sound of the recording therefore experiment with different positions until you achieve the desired sound To this end you can rotate the mic in the stand mount adapter by loosening the screw somewhat and tightening it again 5 STUDIO CONDENSER MICROPHONE G3 User Manual If necessary you can bend the microphone out of its vertical position by using the hinge on the microphone stand D Please make sure to handle the microphone shaft with attention and care to avoid damaging the screw thread In no situation should you ever apply excessive force Of course you can detach the C 3 from the stand mount adapter and attach it to a commercially available suspension mount 5 Audio Connection Use
7. und coming from either side or above below is greatly attenuated This polar pattern is perfectly suited as a reporter mic for two speakers This pattern can also allow you to create a natural reverb or delay effect This is achieved by placing the microphone between the sound source and a wall The direct sound reaches the front membrane first the reflected sound reaches the rear membrane short time later You can adjust the delay reverb time by changing the distance from the mic to the wall 2 3 Omnidirectional If you use the with the omnidirectional polar pattern selected switch position right the microphone is equally susceptible to sound coming from all directions This polar characteristic is particularly well suited to sessions in which a natural sounding recording is sought or when several sound sources surround the C3 4 STUDIO CONDENSER MICROPHONE G3 User Manual 3 Low Cut Filter and Signal Level Attenuation The low cut filter is activated via the left switch located at the front of your C3 switch position left 7 Disruptive low frequency sounds such as subsonic noise snapping and wind sounds can be filtered out When the low cut filter is active when recording a voice from a close distance you get an almost entirely linear frequency response The switch located on the front right side of your activates the 10 dB signal level attenuation switch position right 10 dB This function is

Download Pdf Manuals

image

Related Search

Related Contents

SuperHTM Family E10A-USB Emulator Additional  KOHLER K-10085-9-CP Installation Guide  Coda V10 User's Manual  ZTE Engage LT Manual  Arex Net シリーズ CC-Link 対応 Ao 変換器システム  工作機械取扱説明書 24 言語に対応(PDF:28 kB)  Sync SHM-NPR MP/ 5-Screw Terminal Block  Gefen GTV-DIGAUD-142 cable splitter or combiner      

Copyright © All rights reserved.