image

Contents

1. imagine music AN behringer com behringer
2. 11 12 J 13714 es s E G E IE say CGN ins 8 GEN mz eu Or E rich ORK mc m MI oe N FX FOOTSW ict I NN A 60080 Ne User Manual EUROPOWER PMP2000 800 Watt 14 Channel Powered Mixer with Multi FX Processor behringer com behringer 2 EUROPOWER PMP2000 User Manual HE Table of Contents Thank you 2 Important Safety Instructions eren 3 Legal Disclaimer 00s000n0000s000n0000000n00000000n00n000 0000000 3 Limited Warranty 2or0onssossonennssnnsnnsnnnsnnsnnnsnnsanssnnsnnsnnne 3 Te Introduction e 6 1 1 Before you get started eee 6 144 SKID MERE nort eiie titer tir terrre 1 1 2 Initial operation 1 1 3 Online registration seen 6 2 Control Elements Lees e eee crees eene eene n etn nen 6 2 1 Frontpatnel aceto etie castas 6 2 2 Rear panel essssserssersseesserssersserssersserssersserssersssrssersssrssssee 7 3 Effects Processor eere eerte eere eere e eene eene sena 8 4 Installation eere eren erret e ev erae PES eta eonun ino dp 8 4 1 Mains voltage nsoni 8 4 2 Mains CONNEC Osista 8 4 3 Audio connections nrseessersserssserssserssseessserssseessssrssseeesee 8 4 4 Loudspeaker con
3. 12 EUROPOWER PMP2000 User Manual ED Power Supply Voltage and fuse USA Canada 120 V 60 Hz T10AH250V Europe U K Australia 230 V 50 Hz T5AH250V China Korea 220 V 50 60 Hz T6 3AH250V Japan 100 V 50 60 Hz T12AH250V General export model 230 V 50 Hz T5AH250V 120 V 60 Hz T10AH250V Power consumption max 1 kW Mains connection Standard IEC receptacle Dimensions Weight Dimensions H x W x D approx 11 x 18 Vs x 10 approx 280 x 460 x 270 mm Weight net approx 30 9 Ibs 14 kg Measuring conditions 1 20Hz 20kHz measured at preamp output All channels level controls in center position EQ flat Reference 0 dBu BEHRINGER is constantly striving to manintain the highest professional standards As a result of these efforts modifications may be made from time to time to existing products without prior notice Specifications and appearance may differ from those listed or illustrated behringer com 13 EUROPOWER PMP2000 User Manual FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION FC BEHRINGER EUROPOWER PMP2000 Responsible party name MUSIC Group Services USA Inc Address 18912 North Creek Parkway Suite 200 Bothell WA 98011 USA Phone Fax No Phone 1 425 672 0816 Fax 1 425 673 7647 EUROPOWER PMP518M complies with the FCC rules as mentioned in the following paragraph This equipment has been tested and found to comply with
4. correct polarity Each of the connectors carries only the assigned single signal see tab 4 1 fig 4 6 and the information on the rear panel of the power mixer Professional speaker connector compatible with Neutrik Speakon connectors H ce o front view rear view Fig 4 5 Loudspeaker connector Please be sure to only use commercial Speakon cables type NLAFC for connecting your loudspeakers to the PMP2000 Please check the pin assignment of your loudspeakers and cables dependent on the PMP2000 speaker output you choose 1 1 2 2 RIGHT MONO MAIN POS NEG LEFT MONITOR POS NEG BRIDGE POS NEG Tab 4 1 Polarity configuration of speaker connectors behringer com LEFT MONITOR RIGHT MONO MAIN Fig 4 6 PMP2000 loudspeaker connector assignment 5 Wiring Examples Loudspeaker connection FOH mix RIGHT B MONO MAIN pi PINOUT PMP2000 rear panel part view 2 x BEHRINGER EUROLIVE Stack B1500 amp B1020 both passive Loudspeaker connection monitor mix PMP2000 front panel part view PREAMP OUTPUTS 0000 FX FOOTSW MONITOR LEFT MONO RIGHT 2 x BEHRINGER B300 active Fig 5 1 PMP2000 as stereo amplifier example Please set the MODE switch ZIto LEFT RIGHT for this application 10 EUROPOWER PMP
5. qualified personnel Caution To reduce the risk of fire or electric shock do not expose this appliance to rain and moisture The apparatus shall not be exposed to dripping or splashing liquids and no objects filled with liquids such as vases shall be placed on the apparatus Caution These service instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operation instructions Repairs have to be performed by qualified service personnel EN CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN ATTENTION RISQUE DE CHOC ELECTRIGUE NE PAS OUVRIR Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth nau BPwn Do not block any ventilation openings Install in accordance with the manufacturer instructions 8 Donot install near any heat sources such as radiators heat registers stoves or other apparatus induding amplifiers that produce heat behringer com 9 Donot defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electr
6. strings illuminants and similar parts a Damage defects caused by the following conditions are not covered by this limited warranty e improper handling neglect or failure to operate the unit in compliance with the instructions given in BEHRINGER user or service manuals e connection or operation of the unit in any way that does not comply with the technical or safety regulations applicable in the country where the product is used e damage defects caused by acts of God Nature accident fire flood etc or any other condition that is beyond the control of MUSIC Group behringer com 7 Any repair or opening of the unit carried out by unauthorized personnel user included will void the limited warranty 8 Ifan inspection of the product by MUSIC Group shows that the defect in question is not covered by the limited warranty the inspection costs are payable by the customer E Products which do not meet the terms ofthis limited warranty will be repaired exclusively at the buyer s expense MUSIC Group or its authorized service center will inform the buyer of any such circumstance If the buyer fails to submit a written repair order within 6 weeks after notification MUSIC Group will return the unit C 0 D with a separate invoice for freight and packing Such costs will also be invoiced separately when the buyer has sent in a written repair order 9 Authorized BEHRINGER dealers d
7. to Buy or you can contact the BEHRINGER office closest to you n MUSIC Group warrants the mechanical and electronic components of this product to be free of defects in material and workmanship if used under normal operating conditions for a period of one 1 year from the original date of purchase see the Limited Warranty terms in 4 below unless a longer minimum warranty period is mandated by applicable local laws If the product shows any defects within the specified warranty period and that defect is not excluded under 4 MUSIC Group shall at its discretion either replace or repair the product using suitable new or reconditioned product or parts In case MUSIC Group decides to replace the entire product this limited warranty shall apply to the replacement product for the remaining initial warranty period i e one 1 year or otherwise applicable minimum warranty period from the date of purchase of the original product 3 Upon validation ofthe warranty claim the repaired r replacement product will be returned to the user freight prepaid by MUSIC Group e 4 Warranty claims other than those indicated above are expressly excluded PLEASE RETAIN YOUR SALES RECEIPT IT IS YOUR PROOF OF PURCHASE COVERING YOUR LIMITED WARRANTY THIS LIMITED WARRANTY IS VOID WITHOUT SUCH PROOF OF PURCHASE 2 Online registration Please do remember to register your new BEHRINGER equipment right af
8. 2000 User Manual Loudspeaker connection enabling both mono FOH EUROPOWER PMP2000 and mono monitor mixes MONO Wan HELSE PINOUT cans J br PMP2000 rear panel part view Stereo channel 7 8 Mono Tape in out Mono channel 6 channels TIE 1 4 co 4 Mane L em da channel 5 DAT recorder cmm Vocal Electric microphones 2 x BEHRINGER 2 x BEHRINGER EUROLIVE B1520 passive EUROLIVE F1520 passive Fig 5 2 PMP2000 as double mono amplifier example EN a For this application however please set the MODE switch P to Keyboard MON MAIN ULTRA G GI100 Fig 5 3 Standard setup example behringer com 11 EUROPOWER PMP2000 User Manual 6 Specifications Microphone inputs Type 14 TRS connector unbalanced XLR electronically balanced discrete input circuit Type Mic E I N 20 Hz 20 kHz 1 5 kQ 21 dBu Impedance Max output level DSP 24 bit Texas Instruments 0 source resistance 122 dB 125 dB A weighted m 24 bit Sigma Delta 50 N source resistance 122 dB 125 dB A weighted 64 128 times oversampling 150Q source resistance 121 dB 124 dB A weighted Sampling rate 40 kHz ae Gain 33 dB 8 dB with pad Noise Max input level 12 dBu 8 dB gain Main mix eg 76 dB 80 dB A weig
9. NTOM POWER switch to activate the supply together for channels 1 12 XLR connector The LED above the switch is lit when phantom power is on This is the PMP2000 s graphic stereo equalizer which comprises two units and can be used to adapt the sound to the room acoustics The stereo equalizer is effective on the main mix when both units have been activated with the EQ IN buttons 1land the MODE switch Pilis set to its upper position LEFT RIGHT The stereo equalizer uses one unit each to process the main and monitor mix signals if both units are on and the MODE switch RTlis set to its lower position MON MAIN Use the EQ IN buttons to switch the two equalizer units on or off Press the RUMBLE FILTER button to activate the low cut filter of channels 1 6 This filter eliminates unpleasant bass frequencies e g microphone pop noise The FX TO MON control determines the effects intensity of the multi effects processor as part of the monitor mix Turn the control fully counter clockwise to add no effect to the monitor mix The MONITOR LEVEL control adjusts the volume of the monitor mix Use the MONITOR LEVEL display to control the monitor signal level The upper LED LIM lights up when the built in limiter is activated thus protecting against overload With this MODE switch you can determine whether the PMP2000 works as a stereo amplifier LEFT RIGHT or as a dual mono amplifier MON MAIN Please note th
10. PHANTOM POWER PAD Ag 25 dB 8 tA 48 V Tape inputs outputs amp phantom power switch LEFT RIGHT MON MAIN PREAMP OUTPUTS POWER AMP INPUTS eee a 0000 Mono channel rxFoprsw MONITOR LEFT MONO EUROPOUER PMP 2000 NOTE THERMAL PROTECTION CIRCUIT WILL ACTIVATE IF COOLING VENTS ARE BLOCKED POWER SOURCE 230V 50 80 He 5A STEREO MODE 225 W 8 OHM SERIAL NUMBER 350 Ww 4 OHM BENFINGER DATE CODE 4 OHM MIN LOAD gt N F 4 BRIDGE MODE 800 W 8 OHM www behringer com 8 OHM MIN LOAD C N11999 CLASS 2 WIRING A os NOTE DO NOT CONNECT TO LEFT OR RIGHT PER MODEL PMP2000 OUTPUTS WHEN USING THE BRIDGE OUTPUT CONCEIVED AND DESIGNED SEE OWNER S MANUAL FOR SPEAKER CONNECTION MADE IN CHINA RIGHT LEFT MONO MAIN u MONITOR ENS PINOUT PINOUT Em TIEN POS NEG Rear panel connectors behringer com 6 EUROPOWER PMP2000 User Manual 1 Introduction BEHRINGER is a company with its roots in professional recording studio technology For many years now we have been successful in developing products for studio and live use These include microphones and 19 devices of all kinds compressors enhancers noise gates tube processors headphone amplifiers digital effects devices DI boxes etc monitor and P A speakers and professional live and record
11. at the equalizer function also depends on this switch setting see 15 The FX TO MAIN control functions as FX return for the built in effects processor Use this control to add the desired effect signal to the main mix No effect signal is added when the FX TO MAIN is set fully counter clockwise The MAIN LEVEL control governs the overall volume of the PMP2000 The MAIN LEVEL display reads the output level of the PMP2000 The upper LED LIM lights up when the built in limiter is activated thus protecting against signal peaks Use the FX FOOTSW itch jack to connect any commercially available foot controller It allows you to bypass the effects unit This is the balanced MONITOR output of your PMP2000 Use it to feed an external monitor amp or active wedge These two 1 4 TS jacks allow you to route the output signal to an external amplifier This allows you to say use only the mixing and effect section of the PMP2000 The signal is taken pre power amp Of course you can also use only the left jack as a mono output These two TS jacks can be used to connect external signals such as the main mix signal from an additional mixing console pre power amp Here you will find a list of all multi effect presets available behringer com BT B2 This is the LED level meter of the effects processor Please make sure that the clip LED lights up with signal peaks only If it is lit constantly this indicates tha
12. been electronically or mechanically modified in any way If the product needs to be modified or adapted in order to comply with applicable technical or safety standards on a national or local level in any country which is not the country for which the product was originally developed and manufactured this modification adaptation shall not be considered a defect in materials or workmanship This limited warranty does not cover any such modification adaptation regardless of whether it was carried out properly or not Under the terms of this limited warranty MUSIC Group shall not be held responsible for any cost resulting from such a modification adaptation 3 This limited warranty covers only the product hardware It does not cover technical assistance for hardware or software usage and it does not cover any software products whether or not contained in the product Any such software is provided AS IS unless expressly provided for in any enclosed software limited warranty gt This limited warranty is invalid if the factory applied serial number has been altered or removed from the product 5 Free inspections and maintenance repair work are expressly excluded from this limited warranty in particular if caused by improper handling of the product by the user This also applies to defects caused by normal wear and tear in particular of faders crossfaders potentiometers keys buttons guitar
13. h Electrostatic charges might affect the operation of the unit Unbalanced 14 TS connector Strain relief clamp q Sleeve Sleeve ground shield Fig 4 1 4 mono plug behringer com Balanced 1 4 TRS connector strain relief clamp sleeve sleeve lt lt ground shield ring u cold ve JR hot ve For connection of balanced and unbalanced plugs ring and sleeve have to be bridged at the stereo plug Fig 4 2 4 stereo plug Balanced use with XLR connectors input 1 ground shield 2 hot ve 3 cold ve output For unbalanced use pin 1 and pin 3 have to be bridged Fig 4 3 XLR connectors 9 EUROPOWER PMP2000 User Manual Ya TS footswitch connector lt strain relief clamp O sleeve sleeve pole 1 ground tip Mm pole2 The footswitch connects both poles momentarily Fig 4 4 V TS connector for footswitch 4 4 Loudspeaker connections Your EUROPOWER is equipped with high quality Neutrik Speakon compatible loudspeaker connectors which ensure safe and trouble free operation The Speakon connector was especially developed for high power loudspeakers Once it is plugged in it safely locks into position and cannot be accidentally disengaged It prevents the occurrence of electrical shock and ensures the
14. hted Impedance approx 2 2 KQ balanced 1 1 KQ unbalanced 110 dB 114 dB A weighted 11 dBu In 33 dB gain 0 00196 0 000896 A weighted Signal to noise ratio Distortion THD 4 N Channel fader oo Main mix 0 dB 72 dB 76 dB A weighted Channel fader oo Main Mix 0 dB 71 dB 75 dB A weighted Channel fader 0 dB Mono Line Inputs Type 14 TRS connector balanced Power Amp Specifications RMS 1 THD sine wave both channels driven Impedance approx 80 kQ balanced 40 kQ unbalanced 80 per channel 165W Max input level 30 dBu 40 per channel 250W BAS en THE EINE ach EAE 80 500 W Type 14 TRS connector unbalanced Impedance approx 40 kQ unbalanced 4 28 dBu Max input level Low 60 Hz 15 dB Mid 700 Hz 15 dB High 6 kHz 15 dB Preamp Outputs Left Mono amp Right Type Impedance 14 TRS connector unbalanced approx 1 5 kQ 21 dBu Max output level Power Amp Inputs Type Impedance 14 TRS connector unbalanced approx 47 KQ 21 dBu Max input level behringer com Peak Power both channels driven 80 per channel 225 W 40 per channel 350 W Peak Power bridged mode 80 800 W Loudspeaker connector Professional speaker connectors compatible to Neutrik Speakon Load Impedance Left monitor 4 8 16 0 Right mono main 4 8 16 Q Bridge 8 16 0
15. ician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Use only attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the e manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid AG injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection 16 Where the MAINS plug or an appliance coupler is used as the disconnect device the disconnect device shall remain readily operable Limited Warranty 1 Warranty This limited warranty is valid only if you purchased the product from a BEHRINGER authorized dealer in the country of purchase A list of authorized dealers can be found on BEHRINGER website behringer com under Where
16. ing mixers Our entire technical know how has gone into your PMP2000 This manual first describes the terminology used so that you fully understand the PMP2000 and its functions Please read the manual carefully and keep it for future reference 1 1 Before you get started 1 1 1 Shipment Your PMP2000 was carefully packed at the factory and the packaging is designed to protect the unit from rough handling Nevertheless we recommend that you carefully examine the packaging and its contents for any signs of physical damage which may have occurred during transit Ifthe unit is damaged please do NOT return it to BEHRINGER but notify your dealer and the shipping company immediately Otherwise claims for damage or replacement may not be granted 1 1 2 Initial operation Be sure that there is enough space around the unit for cooling and to avoid overheating please do not place the PMP2000 near radiators etc Before you connect the PMP2000 to the mains please make sure that the voltage setting on the unit matches the local voltage Ifyou set the unit to a different mains voltage be sure to use a fuse of the correct type and rating Please refer to the Specifications for details Blown fuses must be replaced by fuses of the same type and rating Please refer to the Specifications for details The mains connection is made using the enclosed power cord and a standard IEC receptacle It meets all of the inter
17. input sensitivity by 25 dB Thus you can also connect high level line signals to the respective channel input 9 This HI Z LINE input can be used to connect line level signal sources such as keyboards electric and bass guitars 10 This is the channel s balanced XLR microphone input 11 The stereo line input of channels 7 12 can be used to connect for example keyboards with stereo outputs or a stereo drum computer Please remember to use either the microphone or the line input on a specific channel Never use both at the same time This rule applies to channels 1 12 When you connect a mono line signal to channels 7 12 please always use the left input The mono signal will then be reproduced on both stereo sides 7 EUROPOWER PMP2000 User Manual The CD TAPE LINE IN RCA input of channel 13 14 allows you to feed in external stereo signals from your CD player or tape deck for example The CD TAPE LINE OUT RCA output provides the stereo main mix signal of your PMP2000 and can be routed to say a recording machine When the CD TAPE OUT signal is connected to a tape deck whose output signal is routed back to the CD TAPE IN on the PMP2000 feedback can be produced as soon as you start recording Be sure to interrupt the connection to the CD TAPE IN before recording The phantom power supply provides the voltage necessary for the operation of condenser microphones Use the PHA
18. n are applicable unless they constitute an infringement of applicable mandatory local laws w This warranty does not detract from the seller s obligations in regard to any lack of conformity of the product and any hidden defect 9 Amendment Warranty service conditions are subject to change without notice For the latest warranty terms and conditions and additional information regarding MUSIC Group s limited warranty please see complete details online at behringer com MUSIC Group Macao Commercial Offshore Limited of Rue de Pequim No 202 A Macau Finance Centre 9 J Macau including all MUSIC Group companies 5 EUROPOWER PMP2000 User Manual Main Section EURC 00 SMALL HALL 36 REVERSE 03 MIDHALL 40 EARLY REFL OG BIGHALL 44 AMBIENCE 84 PHASER amp REVERB 09 CHURCH 48 STADIUM 86 PITCH amp REVERB RIGHT 10 SMALLROOM 49 AMBENCEFK 88 DELAY amp REVERB 13 MIDROOM 50 DELAY 80 DELAY amp GATED 16 BIGROOM 59 ECHO 91 DELAY amp REVERSE 19 CHAPEL 80 CHORUS 92 DELAY amp CHORUS 20 PLATE 66 RANGER 94 DELAY amp FLANGER 27 SPRING 70 PHASER 96 DELAY amp PHASER 30 GATEDREV 74 PITCHSHET 98 DELAY amp PITCH Stereo line input LEFT MONITOR SECTION 12 24 MONITOR LEVEL CD TAPE UNE IN X e u X9 9 RUMBLE LTE SEFRINGER RIGHT MAIN SECTION EQ IN FX TO MON CD TAPE LINE OUT CLIP
19. national safety certification requirements Please make sure that all units have a proper ground connection For your own safety never remove or disable the ground conductor from the unit or of the AC power cord The unit shall always be connected to the mains socket outlet with a protective earthing connection To avoid damage on the device do not e earth the loudspeaker outputs e connect the loudspeaker outputs to each other e connect the loudspeaker outputs to those of other amplifiers IMPORTANT NOTES CONCERNING INSTALLATION The sound quality may diminish within the range of powerful broadcasting stations and high frequency sources Increase the distance between the transmitter and the device and use shielded cables for all connections behringer com 1 1 3 Online registration Please register your new BEHRINGER equipment right after your purchase by visiting http behringer com and read the terms and conditions of our warranty carefully Should your BEHRINGER product malfunction it is our intention to have it repaired as quickly as possible To arrange for warranty service please contact the BEHRINGER retailer from whom the equipment was purchased Should your BEHRINGER dealer not be located in your vicinity you may directly contact one of our subsidiaries Corresponding contact information is included in the original equipment packaging Global Contact Information European Contact Information Should your country not be li
20. nections ss 9 5 Wiring Examples ccce eee ee cernere etn ene soss 9 6 Specifications eee eee eene eene eese eene testas tnae 11 Thank you Congratulations With the PMP2000 you have acquired a state of the art 14 channel power mixer that sets new standards Right from the start our goal has been to design a revolutionary device that can be used for a great variety of applications And indeed this overwhelming power mixer gives you plenty of functionality and a broad range of connection and expansion options behringer com 3 EUROPOWER PMP2000 User Manual Important Safety Instructions A A Terminals marked with this symbol carry electrical current of sufficient magnitude to constitute risk of electric shock Use only high quality commercially available speaker cables with Ya TS plugs pre installed All other installation or modification should be performed only by qualified personnel This symbol wherever it appears alerts you to the presence of uninsulated dangerous voltage inside the enclosure voltage that may be sufficient to constitute a risk of shock This symbol wherever it appears alerts you to important operating and maintenance instructions in the accompanying literature Please read the manual Caution To reduce the risk of electric shock do not remove the top cover or the rear section No user serviceable parts inside Refer servicing to
21. o not sell new products directly in online auctions Purchases made through an online auction are on a buyer beware basis Online auction confirmations or sales receipts are not accepted for warranty verification and MUSIC Group will not repair or replace any product purchased through an online auction 8 5 Warranty transferability This limited warranty is extended exclusively to the original buyer customer of authorized retail dealer and is not transferable to anyone who may subsequently purchase this product No other person retail dealer etc shall be entitled to give any warranty promise on behalf of MUSIC Group 8 6 Claim for damage Subject only to the operation of mandatory applicable local laws MUSIC Group shall have no liability to the buyer under this warranty for any consequential or indirect loss or damage of any kind In no event shall the liability of MUSIC Group under this limited warranty exceed the invoiced value ofthe product 7 Limitation of liability This limited warranty is the complete and exclusive warranty between you and MUSIC Group It supersedes all other written or oral communications related to this product MUSIC Group provides no other warranties for this product 8 8 Other warranty rights and national law This limited warranty does not exclude or limit the buyer s statutory rights as a consumer in any way The limited warranty regulations mentioned herei
22. s way the danger of creating ground loops or uneven signal levels is eliminated at the outset completely simplifying the handling These effect presets are designed to be added to dry signals If you move the FX TO MAIN MON control you mix the channel signal dry and the effect signal Turn down the FX controls in those channel strips whose signals you don t wish to process 4 Installation 4 1 Mains voltage Before connecting the PMP2000 to the mains please carefully check that your equipment is set to the correct voltage Blown fuses must be replaced by fuses of the same type and rating 4 2 Mains connection The mains connection is made using the enclosed power cord and a standard IEC receptacle It meets all of the international safety certification requirements Please make sure that all units have a proper ground connection For your own safety never remove or disable the ground conductor from the unit or of the AC power cord 4 3 Audio connections The in and outputs of your BEHRINGER PMP2000 are designed as unbalanced 14 mono jacks except for the mono channel line inputs which come as balanced 14 stereo jacks Of course all in and outputs work with both balanced and unbalanced connectors The tape ins and outs are on stereo RCA connectors Please ensure that only qualified personnel install and operate the PMP2000 During installation and operation the user must have sufficient electrical contact to eart
23. se contact the retailer from whom the equipment was purchased Should your BEHRINGER dealer not be located in your vicinity you may contact the BEHRINGER distributor for your country listed under Support at behringer com If your country is not listed please check if your problem can be dealt with by our Online Support which may also be found under Support at behringer com Alternatively please submit an online warranty claim at behringer com BEFORE returning the product All inquiries must be accompanied by a description of the problem and the serial number of the product After verifying the product s warranty eligibility with the original sales receipt MUSIC Group will then issue a Return Materials Authorization RMA number 4 EUROPOWER PMP2000 User Manual M Subsequently the product must be returned in its original shipping carton together with the return authorization number to the address indicated by MUSIC Group 3 Shipments without freight prepaid will not be accepted 4 Warranty Exclusions This limited warranty does not cover consumable parts including but not limited to fuses and batteries Where applicable MUSIC Group warrants the valves or meters contained in the product to be free from defects in material and workmanship for a period of ninety 90 days from date of purchase 2 This limited warranty does not cover the product if it has
24. sted please contact the distributor nearest you A list of distributors can be found in the support area of our website http behringer com Registering your purchase and equipment with us helps us process your repair claims more quickly and efficiently Thank you for your cooperation 2 Control Elements 2 1 Front panel Your EUROPOWER PMP2000 comes with 14 input channels which only differ in terms of pad switch peak LED and interface panel Since the EQ effect monitor and level controls are identical on all channels they will be described only once on the enclosed sheet 1 The FX control determines the signal level that is routed from the respective channel to the built in effects processor Please note that the effects processor is muted as long as the FX TO MAIN control B2 is set fully counter clockwise 2 The HIGH control in the EQ section governs the high frequencies of the respective channel 3 Use the MID control to boost cut the mid range 4 The LOW control allows you to raise or lower the bass frequencies 5 The MON control determines the channel s volume assigned to the monitor mix 6 Use the LEVEL control to set the volume level of the respective channel 7 Usethe CLIP LED to ensure that the input gain is set properly The CLIP LED Should light up only with peak signals but never all the time 8 The PAD button reduces the channel
25. t the effects processor is overdriven which can lead to unpleasant distortion The Effect display reads the currently selected preset Turn the PROGRAM control to select the effect presets Press the control briefly to confirm your selection 2 2 Rear panel B3 Bal The mains connection is on a standard IEC receptacle An appropriate power cord is supplied with the unit FUSE HOLDER Before connecting the unit to the mains ensure that the voltage setting matches your local voltage Blown fuses should only be replaced by fuses of the same type and rating Use the POWER switch to put your PMP2000 into operation The POWER switch should always be in the Off position when you are about to connect your unit to the mains Attention The POWER switch does not fully disconnect the unit from the mains Unplug the power cord completely when the unit is not used for prolonged periods of time This is the RIGHT MONO MAIN loudspeaker output of your PMP2000 where you can connect the right loudspeaker of a stereo system For this purpose switch 21 must be set to its upper position If however you run a mono main mix switch Bil set to its lower position this loudspeaker output provides the main mix signal in mono The impedance of the loudspeaker connected here must not fall below 40 The BRIDGE loudspeaker output allows you to combine the left and right stereo channel in one mono output
26. ter your purchase at behringer com under Support and kindly read the terms and conditions of our limited warranty carefully Registering your purchase and equipment with us helps us process your repair claims quicker and more efficiently Thank you for your cooperation 3 Return materials authorization Legal Disclaimer Technical specifications and appearance are subject to change without notice The information contained herein is correct at the time of printing All trademarks are the property of their respective owners MUSIC Group accepts no liability for any loss which may be suffered by any person who relies either wholly or in part upon any description photograph or statement contained herein Colors and specifications may vary slightly from product BEHRINGER products are sold through authorized dealers only Distributors and dealers are not agents of MUSIC Group and have absolutely no authority to bind MUSIC Group by any express or implied undertaking or representation This manual is copyrighted No part of this manual may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording of any kind for any purpose without the express written permission of Red Chip Company Ltd ALL RIGHTS RESERVED 2010 Red Chip Company Ltd Trident Chambers Wickhams Cay P 0 Box 146 Road Town Tortola British Virgin Islands To obtain warranty service plea
27. the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 ofthe FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Important information Changes or modifications to the equipment not expressly approved by MUSIC Group can void the user s authority to use the equipment behringer com
28. which is useful for applications that require the use of one loudspeaker only To use the BRIDGE output switch 21l must be set to LEFT RIGHT Always connect the BRIDGE jack to a loudspeaker with a minimum impedance of 8 0 Please note that the power delivered to the speaker connected to the BRIDGE output is considerably higher than the power provided to the speakers wired to the parallel speaker outputs Please read the information given on the rear panel of your PMP2000 When using the BRIDGE loudspeaker output NEVER use any of the other two connectors RIGHT MONO MAIN and LEFT MONITOR at the same time This is the LEFT MONITOR loudspeaker output of your PMP2000 to which you can connect the left loudspeaker of a stereo system switch Bilset to its upper position If you do a main mix in mono switch Ril set to its lower position this loudspeaker output provides the monitor signal in mono The impedance of the loudspeaker connected here must not fall below 40 Information on how to properly connect your speaker with regard to polarity can be found on the rear of the unit PIN assignment SERIAL NUMBER 8 EUROPOWER PMP2000 User Manual ED 3 Effects Processor 24 Bit Multi Effects Processor This built in effects module produces high grade standard effects such as reverb chorus flanger delay and various combination effects The integrated effects module has the advantage of requiring no wiring Thi