Home
Avaya Engineering Tips & Tricks: February 2004, Vol. 8 User's Manual
Contents
1. WSS 2250 Icons Appear in InfoCenter on Client Installed Optivity NMS Systems To support new switching devices such as the Wireless Security Switch WSS 2250 and BayStack 5510 switch in Optivity NMS ONMS 10 1 you must install their respective Optivity Integration Toolkit OIT on the ONMS server OIT packages for all Nortel switching and routing products can be downloaded from the Nortel Networks Customer Support website at www nortelnetworks com After installing the OIT packages on your ONMS server it is possible that the icons for BayStack 5510 and WSS 2250 switches may not be populated in the InfoCenter Resources Switches folder on your MS Windows NT 2000 ONMS client The diagram below illustrates an example of what you might encounter amp Resources Switches OL x Objects 31 Change Count 31 Created January 26 2004 1 10 PML a 3 i 10 198778 22 101352002 B8PS2K EDS Botto BayStack 5510 10 135 204 14 10 135 177 2 nA 4704 53 72 a EIS TOP M ladle 190 135 174 5 10 135 204 215 Missing icons To enable the proper icons in InfoCenter you must copy or FTP the GIF files for these devices to the lt drive gt Optivity NMS images devices directory on your Windows NT 2000 client machine After the transfer is completed exit and restart InfoCenter on your client PC for the new icons to take effect see diagram below The GIF files for a given device are incorporated in its OIT package
2. 2 KM buffer credits 100 KM 2KM 50 BB_C Some FC switches can enable a feature that optimizes switch buffering to ensure the highest possible performance on ISLs When this feature is installed on gateway switches the ISLs E_Ports are configured with up to 60 buffer credits The enhanced switch buffers help ensure that data transfer can occur at near full bandwidth to efficiently utilize the connection over extended links Distances vary depending on the manufacturer of the FC switch typically 50 to 100 km Some FC switches have a limited pool of buffers that are rationed amongst its ports to maximize buffer credits usage a more precise formula can be used to calculate a more accurate number of BB_C for a given E port Using the previous example of 100 KM the formula is as follows 2 distance in meters 4311 BB_C round up 2 100000 4311 46 39 or 47 BB_C Another consideration is the achievable throughput for a given distance and frame size For the same 100 KM distance with a 2 Kbyte frame size plus 8b 10b encoding add two bits per byte and the maximum BB_C configurable for that port the following formula can be use to determine what maximum bandwidth that can be achieved hence determining the type of connection BB_C frame size 8b 10b round trip delay 5 usec per KM max achievable BW 60 BB_C 20 000 0 0005 2 4 Gbp s If only a 1 Gbp s connection is available then adjustment BB_C would be req
3. For instance the WSS 2250 gifs NORTEL NETWORKS Engineering Tips amp Tricks your source for relevant pre and post sales engineering information folder can be found under the main NMS_WSS2250 _v110_A folder in the WSS OIT jResources Switches Objects 31 Change Count 31 Created January 26 2004 10 135 178 21 10 135 178 23 10 135 178 22 6 5 Gaal 10 135 200 3 BayStak 5510 19 135 200 2 Ta 47 104 53 72 amp 600 Ottawa BPS2K EDS Botto m A seraa Pee oe OPTICAL ENTERPRISE High Level Overview of OM3500 Shelf Software Upgrade Assuming that there is an NPx in the ring you have a workstation running Preside Site Manager PSM that is able to connect to the NPx and the new software is available on the workstation follow these high level steps to perform the software upgrade Check the CAPs available under Technical Documentation for OPTera Metro 3500 on www nortelnetworks com for more details 1 Before performing the upgrade do the following a Backup Shelf Configurations by connecting to the NP using PSM and selecting the Configuration Backup and Restore option Select the Save All SPs to NP which saves the shelf configurations to the NP Once on the NP you can download the config information to the workstation Save OPE config files by connecting to the OPE either in band or out of band and issuing the save command From PSM obtain Hardware Revision numb
4. NO aoe Engineering Tips amp Tricks your source for relevant pre and post sales engineering information Volume 8 February 2004 Did You Know IN THIS ISSUE Stock Quotes on MCS 5100 When version 2 0 is deployed and the In The Spotlight OS hardened it causes DNS to be e Fibre Channel Distance amp Throughput Calculation turned off In MCS code the URL vee quotes nasdag com has a hard coded Ethernet Switching IP 208 249 117 65 This is a valid IP e Using Mitel Phones with the Untag PVID Only Feature on for NASDAQ quotes URLs are no BayStack 460 longer used in 2 0 with hardened OS only IP addresses which is fine as the IP Telephony MCS code relates URL to IP for quotes e BCM3 5 Professional Call Center Screen Pops in 2 0 Network amp Service Management To get stock quotes working e Howto Make BayStack 5510 and WSS 2250 Icons Appear in From Management Console Modify InfoCenter on Client Installed Optivity NMS Systems IPCM gt Domains Tab set Stock Query Provider field Optical Enterprise Nasdaq e High Level Overview of OM3500 Shelf Software Upgrade set Stock Query URL http quotes nasdaq com Security Virtual Private Network Leave all other fields as default e Contivity 221 Asymmetric Branch Office Tunnel Deployment Guide Login to the IPCM IPCMs cd IMS esm data esm config vi Servers Properties file add line to file Application Embedded true eee position not relevant e Contivi
5. ers for each Circuit Pack under Configuration Inventory Check this info against the OM3500 SW Release 10 and 11 Hardware Baseline document available at www nortelnetworks com in order to make sure that existing hardware will be compatible with the new software 2 Upgrade the NPx a Connect to the NPx and make sure there is enough free disk space There should be more than 20 Meg available b In PSM select Configuration Release Management and Add the software from the workstation to the NPx s hard disk c In PSM select Configuration Upgrade Management and specify the new software release to use The software is loaded from the NPx Go through the following steps to upgrade i Check verifies that hardware is in correct state for upgrade ii Load verifies the checksum and transfers software to the circuit pack iii Invoke resets the circuit pack and applies the software to memory iv Commit deletes previous software version from memory 3 Upgrade the Network Elements by connecting to the shelf and repeating step 2c 4 If necessary upgrade the OPE FPGA firmware In PSM select Configuration FPGA Download Select the OPE module and Load the firmware from the NPx Once the code is loaded the OPE must be Cold Restarted which is traffic affecting Once the upgrade is complete repeat step 1a SECURITY VIRTUAL PRIVATE NETWORK Contivity Contivity 221 Asymmetric Branch Office Tunnel confi
6. gurations for deployment from Central Office locations using the Web GUI Contivity Cisco PIX IPSec peer to peer branch office tunnel using pre shared key authentication NORTEL NETWORKS Engineering Tips amp Tricks your source for relevant pre and post sales engineering information Contivity Cisco PIX IPSec peer to peer branch office tunnel using certificates authentication MORE ABOUT ENGINEERING TIPS amp TRICKS There are many ways in which to read the monthly publication of Engineering Tips and Tricks If you would like to download previous editions Engineering Tips amp Tricks If you are authorized Nortel Networks Channel Partner you can receive it through our bi weekly Partner NewsFlash PNF Sign up for access to our password protected website Partner Information Center and you will be automatically subscribed to PNF note you may unsubscribe at any time If you are an Enterprise customer you can automatically when new software documentation or training is made available on the Customer Support website You select the products set the type of information to receive and choose how often you d like to check for new items and you can turn off this feature at any time It s easy to do If you already have a Nortel Networks User ID Password you can simply Modify Your Profile an easy check to see if you are already personally registered is when you can login to the Customer Supp
7. ic leaving the BayStack port the untagPvidOnly feature enables the BayStack 460 to transmit Voice traffic with the appropriate VLAN header and transmit Data traffic as untagged This prevents broadcasts in one VLAN from being received by both the phone and workstation IP TELEPHONY BCM 3 5 Professional Call Center Screen Pops A popular request among medium size businesses that sell products over the phone are screen pops for Professional Call Center BCM 3 5 comes with Personnel Call Manager that shows screen pops on the registered workstation The application may not be the exact functionality the customer needs yet it indicates TAPI and CTE engine work together In our Richardson lab Windows XP is running with PCM and a sample Visual Basic NET application to show other screen pops that indicate the incoming caller Below is information on the Microsoft TAPI gt TAPI version 3 0 requires Windows 2000 or later gt TAPI version 3 1 requires Windows Server 2003 family or Windows XP Nortel Networks provides a developers program that an individual or a group of developers can develop applications for the BCM Visit the link below Developer Program http www nortelnetworks com prd dpp Developer Categories http www nortelnetworks com prd dpp join ent_mem html Developer Partners http www nortelnetworks com prd dpp ent_bcm_part ners html NETWORK AND SERVICE MANAGEMENT How to Make BayStack 5510 and
8. ort website in the upper left hand corner your name will appear and advise if you are logged in or not If your name does not appear you must Register with Nortel Networks first and then you can Modify Your Profile to receive technical updates This publication will evolve based on your content and information requirements therefore please feel free to provide feedback on the design and organization of this publication to pnf nortelnetworks com receive it through our Nortel Networks Update Subscribe for this monthly e newsletter to provide you with the latest updates on Nortel Networks Products and Solutions Training and Certification Industry News Events Promotions and much more e To receive all types of product updates and technical documentation You can use Nortel Networks Customer Support Email Notifications to alert you
9. ty Cisco PIX IPSec peer to peer branch office tunnel using pre shared key authentication e Contivity Cisco PIX IPSec peer to peer branch office tunnel Save file and restart IPCM for changes using certificates authentication to take effect Tie nrsb 0b tarandi Pavesi More about Engineering Tips and Tricks network Phones connecting to IPCMs Accessing Previous Editions that haven t had this procedure done e Subscribing to eNewsletters will not receive stock quotes NORTEL NETWORKS Engineering Tips amp Tricks your source for relevant pre and post sales engineering information IN THE SPOTLIGHT Fibre Channel Distance amp Throughput Calculation Ports require memory or buffers to temporarily store frames as they arrive then assembled in sequence and delivered to the upper layer protocol The number of buffers or the number of frames a port can store is called a Buffer Credit BB_C Buffer credits within the switches and directors have a large part to play in the distance equation and utilization for a given bandwidth The BB_C in the sending and receiving nodes heavily influence the throughput that is attained within the Fibre Channel Fibre Channel architecture is based on a flow control that ensures a constant stream of data to fill the available pipe A basic rule of thumb says that to maintain acceptable performance one BB _C is required for every 2 km distance covered Distance
10. uired 25 BB_C 20 000 0 0005 1 Gbp s If for a given connection speed and distance and maximum number of BB_C you can the determine maximum achievable bandwidth Connection speed BB_C 2 KM distance in KM max BW 1 Gbp s 60 2 KM 100 KM 1 2 Gbp s At this point adjustment would be made by either decreased BB_C or increased distance ETHERNET SWITCHING Using Mitel Phones with the Untag PVID Only Feature on BayStack 460 Recently a Nortel customer was connecting Mitel VoIP phones to a BayStack 460 switch running BoSS 3 0 software The phone set contains an integrated switch which provides workstation connectivity Traffic from the phone to the BayStack consists of VoIP traffic which is 802 1q tagged and Data traffic from the workstation which is untagged The customer wanted Voice and Data traffic to be placed into different VLANs which were defined on the BayStack To accomplish this the tagging parameter for the port i e 1 in the CLI sample below was set to untagPvidOnly BS460 config vlan ports 1 tagging untagPvidOnly In addition the PVID Port VLAN Id was set to the VLAN Id of the Data VLAN Thus untagged Data packets received by the port are placed into this default VLAN while tagged Voice packets are classified to the appropriate VLAN NORTEL NETWORKS Engineering Tips amp Tricks your source for relevant pre and post sales engineering information For traff
Download Pdf Manuals
Related Search
Related Contents
CO-469 AMÉLIORER LA CARTE TOPOGRAPHIQUE POUR LES Manuale di istruzioni - CNET Content Solutions Manual de Instruções Modelo HEM-631INT Audio-Technica ATH-ANC29 User's Manual NOTICE STORBOX 300 LLAZA France kH + Ca 1, 2, 3 Ajuda do Adobe® Media Encoder CC Invacare Mobile Recliners Copyright © All rights reserved.
Failed to retrieve file