Home
Avaya BayRS, BCC, and Site Manager Software Version 15.3.0.0 Fixed Anomalies User's Manual
Contents
1. B is more specific than route A and the range of the forwarding cache entry where the entry can be installed is smaller than both route A and route B and traffic is flowing such that the forwarding entry will be created and installed after the route switches from route A to route B This may cause connectivity issues as packets will be forwarded incorrectly Q00177452 01 PING_MIB The wfPingRoundTripTime attribute gives inconsistent values on an AN router regardless of actual ping latency Q00206041 01 ATM ATM Service Record remains in IDLE state when bouncing the service record under load Q00206457 01 ATM LLC SNAP ATM PVC does not answer ATMARP Inarp requests nor generates them after the PVC is bounced Q00207284 01 Radius A user lockout condition can occur with manager lock and Automatic Reset enabled if the Radius is unreachable Q00218526 01 OSPF The OSPF process may fault on the router in an unstable network when OSPF is continuously bouncing on several different interfaces on different routers Q00045175 03 Readexe Using the readexe command on the pp5430diag a or pp2430diag a file will fault the router Q00168308 IP The ip bgp_routes N command does not display all the routes to be announced Q00228176 01 SNMP On an ARN with 10 100 ethernet interface configured sending an SNMP Get Next request for MIB2 OspfNbrState or any other MIB2 attribute that BayRS does not support causes the router to fault Q00229377 BGP
2. 0176426 01 Diffserv Diffserv interface may remain in a Not Present state when the router is booted or when the interface is disabled and re enabled Q00177466 01 Scripts Hardware bat does not show information for all PCI slots on a PP5430 router Q00205903 01 Bi_NAT Bouncing NAT globally in a configuration with Bi directional NAT will cause the router to fault Q00138952 01 TFTP Attempting to TFTP a file from a BayRS Router to a UNIX based file system may result in a router fault if the destination file or directory specified in the TFTP command is invalid or administratively denied by the UNIX based TFTP daemon Q00173585 01 NAT A NAT warning message is logged even though there is no problem with NAT Q00206028 01 BCC_ATM Cannot configure PCR or SCR above 4528 cell sec for T3 E3 ATM PMC modules Q00209180 01 PP2430 Unable to set or change the Manager or User password on a Passport 2430 router with a Rev 4 motherboard Q00206380 01 ARN The show hardware slot command will result in error messages Q00209477 01 Dial Backup The ifEntry ifOperStatus and ifSpeed attributes are incorrect if a backup circuit is configured for the interface Q00155044 01 IP A static black hole route is not removed when it is deleted using BCC Q00155634 01 IP The IP forwarding cache entry may not be updated correctly when a route switches to one next hop route A and then back to the original next hop route B This may happen when route
3. Disabling a remote BGP Announce Policy will cause a watchdog fault on the PP5430 router Q00247420 01 SNMP The router will fault when an SNMP request packet is received that contains a community string that is greater than 256 characters in length Q00228099 PP5430 ATM T1 Bouncing an PP5430 ATM T1 interface under load may result in a fault on the router Q00245641 01 TI The TI_INIT process does not release memory on FRE4 and ARE modules when the Serial Port ModemEnable attribute is enabled If many login requests are made this could eventually cause an out of memory fault on the router Q00156420 01 Radius Accounting Different session IDs are used for the Radius accounting stop and start messages for LNS sessions making it difficult to correlate the start stop pairs for each session Q00217703 01 TI The atmarp command may hang when a large number of PVCs are configured Q00248132 01 SNMP The router will fault when an SNMP request packet is received that contains a variable length field value that is greater than the actual size of the data Q00233303 BCC_Circuitless IP A circuitless IP 32 bit mask interface cannot be added after deleting it using BCC Q00250617 ATM ATM service record remains in IDLE state if the service record is bounced while under heavy load Q00229640 01 ATM_PQ ATM PVCs configured with priority queuing fail to recover after a remote side disconnect Q00246791 PP2430 Using the prom v or prom w c
4. Router BCC Fixed Anomalies for BayRS 15 3 0 0 Q00103090 02 Frame Relay IP Circuit remains up after a sync interface configured with Frame Relay is disabled Q00153152 01 Web Server Memory leak occurs when HTTP connections fail This may result in an out of memory fault on the router if this happens continuously Q00154341 02 ATM Copying an ATM PVC using Site Manager gives an erroneous error message in the log message However the ATM PVC is configured correctly and does come up Q00156640 01 ATM_PQ Multiple attempts are required to delete ATM priority queuing Q00174118 01 NAT ECMP In a NAT with RIP2 ECMP configuration changing between Multiple Next Hop Calculation Methods may result in a fault on the router Q00135161 01 Scripts Using install bat to configure Frame Relay on an T1 FT1 interface will prevent Site Manager from being able to open the configuration file However the router will still be able to boot using the configuration file Q00152764 01 IP Traffic Filters Enabling Extended Traffic Filter support with inbound traffic filters with user defined IP criteria configured will cause the router to fault Q00173189 Radius Memory corruption may occur when a remote Radius slot goes down Q00051621 03 Diffserv Diffserv is not working for the filters that use a criteria of URL Q00059191 03 TI Unable to save the configuration after many dynamic changes on very large configuration file Q00103537 02 Scripts i
5. T state Site Manager Fixed Anomalies for 15 3 0 0 Q00083352 01 IP Need the ability to configure the directed broadcast parameter via Site Manager Q00102899 02 Frame Relay After moving a frame relay PVC from one service record to another the control PVC changes to a static PVC and becomes invalid Q00175577 01 Static NAT The static NAT Enable parameter can not be changed and trying to do so can cause the screen to hang Q000871 24 02 NAT There is no choice of public domain when configuring a NAT domain name Q00156804 01 ATM_PQ Cannot configure ATM priority queuing on an interface after deleting it using TI Q00208761 01 Statistics Manager Creating a frame relay query in statistics manager using the wfCircuitShapeHiClippedPkts wiCircuitShapeMediumClippedPkts or wfCircuitShapeLoClippedPkts parameters will result in an invalid object error if circuit mode is chosen instead of table mode The problem is that the wrong mode was chosen not that the parameter is invalid Q00028409 02 ATM Site Manager gives no error message when configuring an ATM service record with a vpi vci pair that already exists The new service record will not be created Q00075416 01 Report Generator Report Generator gives an invalid entry error when run on a 5782 configuration that was saved on the router If the configuration file is created and saved locally there is no error generated Q00175384 01 Protocol Priority A wfCctoptsEntry 1 MIB obj
6. e to ping the VRRP address if two virtual routers are configured on the same interface Q00286620 Radius When the router receives incorrectly formatted Radius Authentication packets i e the packet size is less than the minimum or greater than the maximum size or contains an incorrectly formatted vendor specific attribute the router will fault Q00413482 01 SNMP When an SNMP get request packet is received with an incorrect checksum and also has both the More bit and Do Not Fragment bit set the router may fault Q00065079 02 Circuitless IP When configuring a BGP peer using the circuitless IP address in BCC an extra circuit is created A side effect of the original fix for this CR is that after creating a circuitless IP interface in BCC opening the configuration in dynamic mode in Site Manager would alter the configuration causing some protocols to no longer be configured correctly on the circuitless IP interface Q00391307 Radius When Radius is enabled if an invalid login attempt is made the router logs a message that an invalid radius access response packet was received and disables the Radius server rather than sending an access reject packet Q00412172 VRRP When a VRRP interface changes state gratuitous ARPs are transmitted with the physical MAC address instead of the virtual MAC address Q00421606 VRRP If two virtual routers are configured on the same non token ring interface the second virtual router remains in the INI
7. ect is created each time the protocol priority interface screen is accessed Q00137457 01 BGP When modifying the Address Resolution Type parameter for a BGP peer an invalid data error message appears Q00075522 01 Trap Monitor Trap monitor on the HP UX platform displays additional blank lines and scroll bars Q00228305 Configuration Manager Configuration manager cannot access a 15 0 0 0 or greater configuration file that was created on the router and copied to a local area Q00169249 01 DLSw DLSw PPRI peer specific traffic filter cannot be enabled or disabled through Site Manager Q00248645 01 IGMP Site Manager does not allow configuration of IGMP Static Group starting with 224 x x x Only 224 0 0 x addresses should not be allowed Q00157177 01 TFTP TFTP from Site Manager does not transfer a file greater than 12 MB Q00249835 01 FT1 An FT1 interface that is configured on a PP5430 router is mislabeled as an MCE 1 interface in Site Manager Q00279356 Q002851 15 Q00286783 Q00286772 Q00301785 SNMP Sending incorrectly formatted SNMP request packets will cause the Trap Monitor to exit unexpectedly Q00318621 01 Frame Relay Site Manager cannot access a configuration file that has the wflfRegistrationMode attribute for dial backup circuits set to any value other than the default Q00321950 01 Report Generator Report generator will not work on a 15 0 0 0 or greater configuration file that was saved on the router and copied
8. nst_pp5430 bat does not support the T3 E3 ATM PMC module Q00168709 01 Radius Accounting Different session IDs are used for the Radius accounting stop and start messages for Tl sessions making it difficult to correlate the start stop pairs for each session Q00174392 02 OSPF Incorrect mask is being installed for the default router during network convergence In redundant topologies if there is more than one exit out of the autonomous system via a default route then there could be a connectivity issue when the network converges due to the fact that one of the exit points is now unavailable Q00175589 01 Radius The audit feature does not work for users authenticated via Radius Q00175750 01 ATM A fault occurs when deleting an ATM service record with 75 or more PVCs Q00137521 02 IP Traffic Filters Configuring IP user defined traffic filters where the user data offset is greater than the size of the smallest IP packet that the interface receives such as an OSPF hello or RIP update will cause a fault on an ARE module Q00157429 02 ARP Dynamically enabling host cache aging on a VRRP interface may cause that slot to no longer send ARP requests after the aging timer fires resulting in connectivity issues to hosts off remote slots Q00169296 01 Radius There is no message to notify user that radius server is unavailable when using FTP Q00169925 01 BCC_ATM Changing the framing mode on an ATM T3 E3 interface in BCC has no effect Q0
9. ommand on the pp2430boot ppc file on the PP2430 router will cause the router to fault The boot prom is not supported on the PP2430 router Q00254601 01 IP_Multicast The router may send multicast packets out of sequence when unicast traffic is received simultaneously Q00206828 01 Ping MIB The Ping MIB wfPingTypeOfService attribute was changed to obsolete in BayRS 15 1 0 0 causing third party applications that set this MIB to fail The MIB is now read write again but the only valid value is 1 Q00251246 PPP The IPCP type 1 address negotiation fails subsequent to a type 3 address negotiation failure Q00253951 01 IP IP doesn t send an ICMP redirect packet when it is on the same interface that the original packet came in on Q00152897 02 ATMLANE In an ATMLANE bridging environment after the ATM slot resets the router does not respond to the LE_ARP from the switch causing the switch to not use the data direct VC that has been created Q00218436 BCC _Circuitless IP In a configuration with a circuitless IP interface the wfLineMappingCct attribute is set to 1 for all subsequent circuits created using BCC This attribute should be incrementing so that each circuit has a unique ID Q00063509 01 DSQMS Using BCC to configure a DSQMS queue may cause the queue to remain in an invalid state Q00259789 04 SNMP Running the SNMP Certs test suite will cause an out of memory fault on the PP2430 and PP5430 routers This fault will also occ
10. to a local area Q00284138 01 Multilink PPP When a new circuit is added to an already existing multilink bundle BOFLs will only be sent across the new circuit
11. ur on the ARE module on the BN router Q00305463 IP_Traffic_Filters In a configuration with multiple IP user defined traffic filters and Extended Traffic Filters enabled configuring a new IP user defined traffic filter causes the IP user defined traffic filter previous to it in the filter list to go into an invalid state Q00218468 01 OSPF A BayRS router may retransmit an LSA type 3 forever if the LSA entry is aged out of the router s own LSDB just after it has transmitted the LSA to it s neighbor Q00302720 02 SNMP When an SNMP request that has 1270 bytes or more of data is received on an ARN or AN router that has the buffer size set to 1824 default for non token ring ARN and AN routers the router will fault or hang Q00305450 IP_Traffic_Filters IP traffic filters with precedence greater than 31 are deleted when Extended Traffic Filter support is disabled then enabled Q00317176 SNMP When an SNMP request packet that contains an SNMP community length field that is greater than the size of the packet is received on an ATM interface on a BN router the router will fault Q00283457 02 PPP Multilink In a PPP Multilink configuration in which circuits within the bundle are on different slots the IP circuit will fail to come up when the router is booted from a slot other than the one configured in the wfPppCircuitLampreyCompDisable attribute as long as that slot has a circuit in within the bundle Q00321824 VRRP It is not possibl