1.
2. Program Departure time Return time 4 q Bed time NOTE For temperature increases Prog 1 and 3 allow at least 15 minutes per C If you have lowered the temperature by 3 C during the night and you wake up at 7 AM change the setting at 6 15 AM For savings to be obtained you must lower the temperature for a period of 2 to 3 times the delay required to bring the temperature back to your comfort level Example If your system takes one hour to go from your saving temperature level to your comfort temperature level it is useless to lower the temperature for a period less than 3 hours a To program your schedule 1 Press on PGM button to access the programming mode 2 Press on Day button to select the day to be programmed You can select all days of the week by pressing on Day button for 3 seconds 3 Press on PGM button to select program 1 2 3 or 4 4 Press on Hour and Min buttons to program the time 5 When you have completed your programming press on Mode button to exit this function b To erase a program Select the program using PGM and Day buttons and press on Clear button The time field displays when the program is inactive c Example 1 Comfort period from 7 00 AM to 10 30 PM Economy period from 10 30 PM to 7 00 AM Identical schedule for all days of the week 1 Press on PGM button to access the programming mode 2 Press on Day button 3 seconds to select every day of t
3. 1 Temperature sensor with a 15 foot extension TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK Keep air vents of the thermostat clean and free from obstructions 1 Connecting wires and mounting thermostat Connect the rear thermostat wires to the power supply and to the load using solderless connectors for copper wires See schematic diagram Push the excess wire back into the electrical box to prevent interference with the thermostat Secure the thermostat using two 2 6 32 screws Once the ther mostat is properly installed return power to heating system NOTE All cables and connec tions must conform to the local electrical code WARNING 120 V LINE j DOUUUUOU 60HZ El annann Special CO ALR solderless connectors must be used when connecting with aluminum conductors 2 Connecting temperature sensor wire Connect the temperature sensor wire to the two lower screws of the terminal block at the back of the thermostat no polarity need to be respected The wire must pass outside the electrical box and fol low the wall down to the floor The sensing probe should be placed in a representative heat area for maximum system perfomance The sensing probe should be cen tered between the wires in the mat The temperature sensor wire cannot cross any heater wires and the sensing probe must not be directly or adjacent to a heat
4. selected temperature or W changes the temperature setting Thermostat TH111GFCI P 2000 W NI 120 VAC 88 88 MOTUWETHFRSASU gt 98 30 i Sea L aT Reset O Es Hour Comfort temperature ___ Q Pm Clear ee all Made Economy temperature N v Il _ Up amp down to adjust the temperature setting INSTALLATION Time and day of the week Floor or setting temperature O Reset To set the day F To set the time To set the programming lt To erase a program lt To select the operating mode This thermostat is designed to control floor electric heating systems The resistive load must not exceed 2000 watts NI 120 VAC 16 7 A The thermostat is equipped with a ground fault circuit interrupter GFCI and therefore the isolation of the line and load are required for operation The polarity of line connection line and neutral must be respected During a ground fault only the current in the black wire line of the load will be cut off Connect thermostat as shown on diagram Electricians or experienced technicians should install the thermostat This thermostat is designed to be used with a circuit breaker PARTS INCLUDED One 1 TH111 GFCI P 120 VAC thermostat Two 2 6 32 screws Four 4 solderless connectors for copper wire One
5. the heating system and call customer service or return the thermostat to your supplier for verification If the warning light comes on during normal operation cut off power to the heating system and have an electrician verify the installation The TH111GFCI P has two 2 operating modes MANUAL M This mode allows you to maintain a constant temperature of the floor 1 To activate this mode press on Mode button to display the 4 icon 2 Set the desired temperature using the 4 W buttons or select the pre programmed ped or or til settings To select the til setting press on and simultaneously AuTomatic This mode executes your own programming To activate this mode press on Mode button to display the icon auto The or icon indicates which temperature setting is used Also the icon of the program number will be shown 920 111 021 00 1 A 1 2 Memory back up In the event of a power failure an internal circuit will maintain the programming and the time But only the time could have to be set if power failure is more than 2 hours Early Start function The thermostat is providing a built in function enabling it to calculate the optimum time to start the heating system to achieve the desired temperature setting at the programmed time This function could start the heating system as early as 6 hours prior to the programmed time To enable this function set the switch E S to ON at
6. aube technologies MODEL TH111GFCI P 120 VAC SUMMARY e OPTIONS SELECTION At the back of the thermostat there are three selection switches to set at your preferences Temperature in C or F time in 12 or 24 hours and Early Start function TO SET TIME AND DAY Press on DAY HOUR and MIN buttons to adjust time and day TO RECORD THE X COMFORT SETPOINT TEMPERATURE Select chosen setpoint temperature by using or W button Press on 0 button 2 to 3 seconds until icon appears on display TO RECORD THE ECONOMY SETPOINT TEMPERATURE Select chosen setpoint temperature by using sor W button Press on button 2 to 3 seconds until icon appears on display CHECKING GROUND FAULT CIRCUIT INTERRUPTER GFCI Adjust the setpoint temperature until heating indicator appears on display Press on TEST button The test is conclusive if the warning light GFI on thermostat is ON and power to the load is cut off fff remain on display though If these events do not occur check the installation Press on RESET button to reset the GFCI OPERATING MODES To select an operating mode use MODE button AUTO MAN Warning light of the GFCI Test button of the GFCI Comfort Economy amp Vacation temperature settings Operating modes Heating indicator Program number Runs the program or W shows temperature setting and can override temporarily your programming up to the next program Maintains the
7. he week 3 Press on Hour button to enter 7 00 AM Prog 1 X 4 Press on PGM button again to select Prog 2 and press on Hour and Min buttons to enter 10 30 PM 5 Press on Mode button to exit this function d Example 2 Comfort period Monday to Friday from 6 15 AM to 8 15 AM and from 5 00 PM to 10 00 PM Schedule Day MON TUES WED THU FRI SAT SUN NOTE t is faster to program the same schedule for every day and then modify the exception days 1 Press on PGM button to access the programming mode 2 Press on Day button 3 seconds to select every day of the week 3 Press on Hour and Min buttons to enter 6 15 AM Prog 1 0 4 Press on PGM button to select Prog 2 q and Hour and Min buttons to enter 8 15 AM 5 Repeat step 4 to enter Prog 3 5 00 PM and Prog 4 10 00 PM NOTE When making modifications make sure you are in the right program To modify the Saturday and Sunday schedules 6 Press on Day button until SA or SU is displayed 7 Press on PGM button to select Prog 1 3 and Hour and Min buttons to enter 7 30 AM 8 Press on PGM button to select Prog 2 and then Clear button to erase it 9 Press on PGM button to select Prog 3 0 and then Clear button to erase it 10 Press on PGM button to select Prog 4 q and then Hour and Min buttons to enter 11 00 PM 11 Press on Mode button to exit this function Temporary or permanent temperature bypass T
8. his operation allows you to temporarily modify the floor temperature while you are in the Automatic mode Simply press on or W buttons to select the desired temperature or the X or button to select the Comfort or Econo settings you have programmed This temperature will be maintained until the beginning of the next programmed schedule You can also switch to the Vacation setting for a prolonged absence by pressing on X and atthe same time The display will show m icon In that case the temperature bypass is permanent To return to the normal operating mode press on Mode button If you wish to immediately return to the programmed settings press on Mode button twice CHARACTERISTICS e Model TH111GFCI P 120 VAC e Supply 120 VAC 50 60 Hz Load 16 7 A maximum resistive only e Power 2000 watts NI 120 VAC e Ground fault circuit interrupter GFCI 10 mA TRIP LEVEL e Approvals CSA C US e Display range 0 to 60 C 32 to 140 F 5 to 40 C 40 to 104 F 28 C 82 F Econo default setting 18 C 64 F Storage 20 to 50 C 4 to 120 F Setting range Comfort default setting WARRANTY AUBE TECHNOLOGIES INC ONE 1 YEAR LIMITED WARRANTY This product is warranted against material defects and workmanship in normal use for a period of one year from the date of the original purchase from author ized dealers During this period AUBE technologies inc will repair or replace the prod
9. ing wire Power up off When power is applied for the first time the display must show the time 00 00 the floor temperature and the manual mode icon m J Other information might show up on the display if installation is defective or does not comply with the instructions The warning light GFI must be The message LO or HI will appear on the display if the temperature sensor is defective or the temperature is below 0 C 32 F or higher than 60 C 140 F Also the heating indicator will be present on display and the relay will be closed current going in the load Checking ground fault circuit interrupter GFCI nae Maama Thermostat THITIGECEP 2000 W NI 120 VAC An AN o UUU Test m y Reset ix Ws z OO 4 OPERATING MODES Adjust the setpoint temperature until heating indicator appears on display Press on TEST button The test is conclusive if the warning light GFI on the thermostat is ON and power to the load is cut off If these events do not occur check the installation Press on RESET button to reset the GFCI If the GFCI test fails Check the load wires The thermostat must be in heating mode to carry out the test heating indicator ON The GFCI test should be carried out monthly If the test fails cut off the electric power to
10. the back of the thermostat PROGRAMMING Programming the time and day 1 Set the time using the Hour and Min buttons 2 Set the day using the Day button Programming the Comfort Economy and Vacation settings The Comfort bog Economy q and Vacation I settings respectively represent the temperatures that you wish to have during the day 3m at night or while you are away at work q or while you are away for an extended period iM To program your settings a To program the Comfort temperature select the desired degree using the 4 buttons and press the button until the X icon is displayed app 3 seconds b z To program the Economy temperature select the desired degree using the 4 WV buttons and press the button until the icon is displayed app 3 seconds c To program the Vacation temperature select the desired degree using the 4 buttons and press on the i and buttons simultaneously until the ty icon is displayed app 3 seconds d Press the Mode button to exit this function and return to the normal operating mode Schedule programming The TH111GFCI P allows 4 setting changes for each day of the week There are no pre set programs The programs are tailored to perfectly adapt to your life style The principle is very simple For each day enter the time at which you wake up P1 the time you leave for work P2 the time you arrive back home P3 and the time you go to bed P4
11. uct with a new or of equivalent quality at AUBE S option without charge any product proven defective in normal use Warranty does not cover transportation costs Nor does it cover a product sub jected to misuse or accidental damage This warranty does not cover the cost of installation removal or reinstallation This limited warranty is in lieu of all other warranties obligations or liabilities expressed or implied by the company In no event shall AUBE technologies inc be liable for consequential or incidental damages resulting from installation of this product Some states or provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential dam ages so the above exclusions or limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state The defective product and the original sale receipt must be returned to the origi nal dealer or shipped pre paid insured and addressed to Aube technologies inc 705 Montrichard Iberville Quebec Canada J2X 5K8 www aubetech com service aubetech com If you have any questions concerning the installation or programming of this prod uct please call our technical assistance at 450 358 4600 for the Montreal area or 1 800 831 AUBE for outside area Monday to Friday between 8 30 AM and 5 00 PM Eastern time 09 05 02 920 111 021 00 1 A 2 2