Home
Aube Technologies TH110 User's Manual
Contents
1. INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS HEREBY LIMITED TO THE THREE YEAR DURATION OF THIS WARRANTY Some provinces and states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from province or state to another 75 Customer Assistance If you have any questions about the product installation or operation or concerning the warranty contact us at 705 Montrichard Saint Jean sur Richelieu Quebec J2X 5K8 Canada Tel 450 358 4600 Toll free 1 800 831 AUBE Fax 450 358 4650 Email aube service honeywell com For more information on our products go to www aubetech com p J As an ENERGY star partner Aube Technologies has enus determined that this product meets the ENERGY STAR guidelines for energy efficiency 400 110 000 A 2 6 05 2 2
2. 4 technologies Description Aube s TH110 programmable thermostat can be connected to an electric heating system such as an electric baseboard a radiant ceiling a floor heat ing system an electric convector etc It is not compatible with a central heat ing system Time and day On Standby Appears during the switch n 2 po aq setpoint display y MOTUWETHER Temperature Operating Stand by ng F mode icons Preset temperature Sl see tl F icons D h A Heating 4 Q gt indicator 49449 bey To set the day Hour Periods STP GI gt To set the time Min a m TO program the schedule Temperature x q A preset buttons Cear To skip a period Med To select the ee ae operating mode adjustmen O a x i Set the switch to Standby to cut power to the heater This will not affect the time and temperature settings Connection TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK The installation must be carried out by an electrician All cables and connections must conform to the local electrical code Special CO ALR solderless connectors must be used when connecting with aluminum conductors Install the thermostat onto an electrical box Install the thermostat about 5 feet high on an inside wall facing the heater Avoid locati
3. Aube warrants this product excluding battery to be free from defects in the workmanship or materials under normal use and service for a period of three 3 years from the date of purchase by the consumer If at any time during the warranty period the product is determined to be defective or malfunctions Aube shall repair or replace it at Aube s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii contact Aube Aube will make the determination whether the product should be returned or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Aube that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Aube s sole responsibility shall be to repair or replace the product within the terms stated above AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some provinces and states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT THE DURATION OF ANY IMPLIED WARRANTIES
4. amming mode TH110 Troubleshooting Problems Solutions The thermostat s screen is blank The thermostat s switch is on Standby The measured temperature is below 0 C LO is displayed 32 F Heating is activated i i The measured temperature is above 50 C HI is displayed 122 F The thermostat was without power for The wrong time is displayed more ihan 2 hours The thermostat is located in a spot The measured temperature is wrong exposed to an air draft The heater is always On Bad installation The thermostat indicates that heating is On but the heater is not On Bad installation Check that the thermostat is in Automatic mode Check also the energy saving schedule and clock settings The temperature does not change accord ing to the energy saving schedule Technical Specifications Power 240 Vac 50 60 Hz Load 16 7 A maximum resistive only Power 4000 watts NI 240 Vac Display range 0 C to 60 C 32 F to 140 F Display resolution 0 1 C 0 1 F Setpoint range 5 C to 30 C 40 F to 86 F Setpoint interval 1 C 1 F Storage 20 C to 50 C 4 F to 120 F Approvals CSA UL Data backup In the event of a power failure most settings are saved Only the time must be re adjusted if the power failure lasts more than 2 hours The thermostat will return to the mode that was active prior to the power failure V Warranty
5. nual mode and displays the actual temperature Press the Hour and Min buttons to set the thermostat s clock Press the Day button to set the day Temperature Setting Setpoint The thermostat normally displays the actual temperature To view the set point press the a or w button briefly The setpoint will appear for the next 5 seconds To change the setpoint press the a or w button until the desired temperature is displayed To scroll faster hold the button Using a preset temperature The thermostat has 3 preset temperatures gt Comfort temperature x gt Economy temperature gt Vacation temperature p Icon Intended use Default setting 21 C 70 F i Comfort when at home Economy when asleep or away from home 16 C 62 F D Vacation during prolonged absence 10 C 50 F To use the Comfort or Economy temperature press the X or button respectively The corresponding icon will be displayed To use the Vacation temperature press both X and buttons simulta neously The icon will be displayed Storing a preset temperature To store the Comfort or Economy temperature Set the desired temperature using the a or w button Press and hold the appropriate button X or for approximately 3 seconds until the corresponding icon is displayed Press the Mode button To store the Vacation temperature Set the desired temperature using
6. ons where there are air drafts such as the top of a staircase or an air outlet dead air spots such as behind a door or direct sun light Do not install the thermostat on a wall that conceals chimney or stove pipes Connect the thermostat wires to the 240 V line and to the load using sold erless connectors for copper wires Power Push the excess wire back into the electrical box to prevent interference with the thermostat Secure the thermostat using two 6 32 screws Return power to heating system NOTE Always keep the thermostat s vents clean and unobstructed TH110 TH110 User Guide Programmable Thermostat Configuration The configuration switches are on the back of the thermostat Default factory settings are inside the gray cells Configurations UP DN sw Not used Sw2 Early Start Disable Enable SW3 Time format 12 hour 24 hour sw4 Temperature format F C a Early Start can be used in Automatic mode only When this function is enabled the thermostat calculates the optimal time to start heating in order to obtain the desired temperature by the set time The thermostat re assesses the start time daily based on the previous day s perfor mance b If you change the temperature display format the preset temperatures x qand cp will return to their default settings Power up Upon power up the thermostat is in ma
7. the a or w button Press and hold both X and buttons simultaneously for approximately 3 seconds until the icon is displayed Press the Mode button 400 110 000 A 2 6 05 1 2 Operating Modes Automatic The temperature is set according to the energy saving schedule To place the thermostat in this mode press Mode until is dis played The icons of the current period and preset temperature are also dis played Temporary Bypass If you modify the setpoint by pressing the a v x or button when the thermostat is in automatic mode the new set point will be used until the end of the current period When the next period starts the temperature set for that period becomes the new set point m Manual The energy saving schedule is not used The temperature must be set manually To place the thermostat in this mode Press Mode until is displayed set the temperature using the a v x or button ap Vacation The thermostat is set to the Vacation temperature Press both x and buttons simultaneously to place the thermostat in Vacation mode Energy saving Schedule The schedule consists of 4 periods per day which represents a typical week day You can program the thermostat to skip the periods that do not apply to your situation For example you can skip periods 2 and 3 for the weekend Period Description Associated preset temperature r Wake up x ToTie Awa
8. y from home get aT Return home 30 M Sleep q The Comfort X temperature is used in periods 1 and 3 and the Economy C temperature is used in periods 2 and 4 For example when the period changes from 1 to 2 the setpoint automatically changes from Comfort setting x to Economy setting Q You can have a different program for each day of the week i e each period can start at different time for each day of the week The thermostat has been programmed with the following schedule Period Setting MO TU WE TH FR SA SU m ae 6 00 6 00 6 00 6 00 6 00 6 00 6 00 a AM AM AM AM AM AM AM 8 00 8 00 8 00 8 00 8 00 f TET AM AM AM AM AM J J 7 pN P 6 00 6 00 6 00 6 00 6 00 Aia i PM PM PM PM PM i 10 00 10 00 10 00 10 00 10 00 10 00 10 00 mm PM PM PM PM PM PM PM To modify the schedule Press Pgm to access the programming mode Period 1 is selected Press Day to select the day to program hold for 3 seconds to select the entire week Press Hour and Min to set the start time of the selected period or press Clear if you want to skip the period is displayed Press Pgm to select another period or press Day to select another day Then repeat step 3 00 Press Mode to exit the programming mode NOTE If no button is pressed for 60 seconds the thermostat will automati cally exit the progr