Home

Aube Technologies TH106-A-347S4 User's Manual

image

Contents

1. Technical Specifications Power 347 VAC 50 60 Hz Minimum load 700 W 2 A resistive only Maximum load 5800 W 16 7 A resistive only Display range 0 C to 60 C 32 F to 140 F Display resolution 0 5 C 1 F Setpoint range 5 C to 30 C 40 F to 86 F Setpoint interval 0 5 C 1 F Storage 20 C to 50 C 4 F to 120 F TH106 A 347S4 V Warranty Aube warrants this product excluding battery to be free from defects in the workmanship or materials under normal use and service for a period of three 3 years from the date of purchase by the consumer If at any time during the warranty period the product is determined to be defective or malfunctions Aube shall repair or replace it at Aube s option lf the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii contact Aube Aube will make the determination whether the product should be returned or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Aube that the defect or mal function was caused by damage which occurred while the product was in the possession of a consumer Aube s sole responsibility shall be to repair or replace the product within the terms stated above AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY I
2. Schedule The schedule consists of 4 periods per day which represents a typi cal weekday You can program the thermostat to skip the periods that do not apply to your situation For example you can skip periods 2 and 3 for the weekend Associated temperature preset o e M Pe ee The Comfort temperature is used in periods 1 and 3 and the Economy 4 temperature is used in periods 2 and 4 For example when the period changes from 1 to 2 the setpoint automatically changes from Comfort setting lt to Economy setting You can have a different program for each day of the week i e each period can start at different time for each day of the week The thermostat has been programmed with the following schedule rea soara wo 1u we mm er sa so AM AM AM AM AM AM AM e e 5u a aaa a E AM AM AM AM AM mo 7 6 00 6 00 6 00 6 00 6 00 eae ae PM PM PM PM PM 10 00 10 00 10 00 10 00 10 00 10 00 10 00 mi PM PM PM PM PM PM PM To modify the schedule Press Pgm to access the programming mode Period 1 is selected Press Day to select the day to program hold for 3 seconds to select the entire week or press Clear if you want to skip the period is displayed Press Pgm to select another period or press Day to select another day Then repeat step 3 Press Hour and Min to set the start time of the selected period 4 400 106 011
3. A 22 1 07 2 3 Press Mode to exit the programming mode NOTE If no button is pressed for 60 seconds the thermostat will automatically exit the programming mode Power Outage During a power outage the settings are stored in memory However only the thermostat s clock must be re adjusted if the power failure lasts more than 2 hours When power comes back the thermostat will return to the operating mode that was active prior to the power failure Troubleshooting PROBLEM SOLUTIONS This condition is normal Under normal operation the thermostat housing can reach a temperature between 35 C 95 F and 40 C 104 F Thermostat is hot The thermostat is exposed to air draft Eliminate the draft The sticker on the thermostat s screen has not been removed Wrong temperature is displayed The thermostat was without power for Wrong time is displayed OEE ETA Temperature does not Check that the thermostat is in Automatic change according to the mode Check the schedule and clock set programmed schedule tings The thermal protection device on the heater is open This can happen after a power failure or if the heater is obstructed by furniture or curtains Display disappears and reappears after a few minutes Display looks faded The heating system is less than the when heating is acti required minimum load This thermostat vated cannot be used below that rating
4. NCI DENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WAR RANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some provinces and states do not allow the exclu sion or limitation of incidental or consequential damages so this limi tation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS HEREBY LIMITED TO THE THREE YEAR DURATION OF THIS WARRANTY Some provinces and states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from province or state to another ZA Customer Assistance If you have any questions about the product installation or operation or concerning the warranty contact us at 705 Montrichard Saint Jean sur Richelieu Quebec J2X 5K8 Canada Tel 450 358 4600 Toll free 1 800 831 AUBE Fax 450 358 4650 Email aube service honeywell com For more information on our products go to www aubetech com p l As an ENERGY STAR partner Aube Technologies has determined that this product meets the ENERGY STAR guidelines for energy efficiency 400 106 011 A 22 1 07 3 3
5. TH106 A 347S4 technologies Temperature preset buttons HH x Appears when the setpoint is displayed Time and day Set the day Temperature Set the time JO Operating C mode icons Program the schedule T fmm Temperature Skip a period preset icons Heating power apenas indicator operating mode Periods Temperature adjustment buttons Description This programmable thermostat can be used to control an electric heating system such as an electric baseboard heater a radiant ceil ing a radiant floor a convector etc The thermostat cannot be used with the following e aresistive load greater than 16 7 A e aresistive load less than 2A e a system driven by a contactor or relay inductive load e acentral heating system SUPPLIED PARTS e One 1 thermostat e Two 2 6 32 screws e Two 2 solderless connectors Installation TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK THE INSTALLATION MUST BE PERFORMED BY AN ELECTRI CIAN gt All cables and connections must conform to the local electrical code gt Special CO ALR solderless connectors must be used when con necting with aluminum conductors gt Install the thermostat onto an electrical box gt Install the thermostat about 5 feet high on an inside wall facing the heater gt Avoid locations where there are air drafts Such as the top of a S
6. he Comfort or Economy temperature press the x or 4 button respectively The corresponding icon will be displayed e To use the Vacation temperature press both and buttons simultaneously The icon will be displayed Storing a preset temperature To store the Comfort or Economy temperature Set the desired temperature using the a or v button Press and hold the appropriate button or for approximately 3 sec onds until the corresponding icon is displayed TH106 A 347S4 To store the Vacation temperature Set the desired temperature using the a or v button Press and hold both x and buttons simultaneously for approximately 3 seconds until the c icon is displayed Operating Modes Automatic The temperature is set according to the programmed schedule To place the thermostat in this mode press Mode until is displayed The icons of the current period and preset temperature are also displayed Temporary Bypass If you modify the setpoint by pressing the a Vv amp or button when the thermostat is in automatic mode the new setpoint will be used until the end of the current period When the next period starts the temperature set for that period becomes the new setpoint ry Manual The programmed schedule is not used The temperature must be set manually To place the thermostat in this mode Press Mode until is displayed Set the temperature using the a v lt or button
7. t heating in order to obtain the desired temperature by the set time The thermostat re assesses the start time daily based on the pre vious day s performance b If you change the temperature display format the preset temperatures X and will return to their default settings c 15 second cycles should be selected in most cases as it provides better temperature control 15 minute cycles must be selected if you have a fan equipped heater or if 15 second cycles causes light flickering especially in rural regions Power up Upon power up the thermostat is in manual mode 7 and displays the actual ambient temperature Press the Hour and Min buttons to set the thermostat s clock Press the Day button to set the day Temperature Setting Setpoint The thermostat normally displays the actual temperature To view the setpoint press the a or v button briefly The setpoint will appear for the next 5 seconds To change the setpoint press the a or v button until the desired temperature is displayed To scroll faster hold the button Using a preset temperature The thermostat has 3 preset temperatures gt Comfort temperature x gt Economy temperature gt Vacation temperature Icon Intended use Factory setting Comfort when at home 21 C 70 F Economy when asleep or away from home 16 5 C 62 F x Vacation during prolonged absence 10 C 50 F e To use t
8. taircase or an air outlet dead air spots such as behind a door or direct sunlight gt Do not install the thermostat on a wall that conceals chimney or stove pipes gt The thermostat wires are not polarized either wire can be con nected to the load or to the power supply NOTE Always keep the thermostat s vents clean and unobstructed TH106 A 347S4 User Guide Programmable Thermostat Connect the thermostat wires to the line wires and to the load wires using solderless connectors for copper wires 2 wire installation 4 wire installation Push any excess wire back into the electrical box Before installing the TH106 thermostat base install provided adapter plate U shaped on 347V electrical box which is bigger than regular electrical boxes NOTE If necessary before re installing the front component config ure the thermostat see section 3 Return power to heating system 400 106 011 A 22 1 07 1 3 Configuration The configuration switches are on the back of the thermostat The factory settings are indi cated by the gray cells in the following table KE ge co KE x KE Temperature time format C 24 hour F 12 hour a E Early Start can be used in Automatic mode only When this func tion is enabled the thermostat calculates the optimal time to star

Download Pdf Manuals

image

Related Search

Related Contents

Verbatim 52611 energy-saving lamp  EXSYS EX-47005  Carte d`instruction Elexo XXL Chaise de douche-toilette  TM-2-4 Deutsch    Manual de Usuario Servicio de Ayuda Tecnológica Online  SoundMex Documentation SoundMex Documentation  

Copyright © All rights reserved.
Failed to retrieve file