Home

Aube Technologies TH114 User's Manual

image

Contents

1. 24 V Low Voltage Power Base Install the control module onto the base Apply power to the heating system 0O00 Verify the installation by checking that the heating system can be turned on or off using the thermostat 4 1 Single SSR with Built in Transformer RT850T PB112 024T e J co c W W R R Qs Electrical Panel Blue Red L2 L1 Black Heater 4 2 Multiple SSRs with External Transformer PB112 024T Electrical CWRS OSSY ul kE i VDC External 24 V vac Transformer a Peer ees COM VDC vac OQ EEEE EE COM Heater RT850 Technical Specifications Maximum load 0 5 A 24 VAC Heating cycle length 15 seconds Operating temperature 32 F to 122 F 0 C to 50 C Storage 4 F to 122 F 20 C to 50 C Size H W D 124 x 70 x 23 mm 4 89 x 2 76 x 0 91 in Wire gauge 14 to 22 AWG 400 112 024 A 18 1 06 1 1
2. UBE Technologies Inc will repair or replace at our option and without charge any defective product which has been used under normal conditions The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installa tion This warranty cancels and replaces any other manufacturer s express or implied warranty as well as any other company commit ment AUBE Technologies Inc cannot be held liable for related or random damages following the installation of this product The defective product as well as the purchase invoice must be returned to the place of purchase or mailed prepaid and insured to the following address 705 Montrichard Saint Jean sur Richelieu Quebec J2X 5K8 Canada T 450 358 4600 1 800 831 AUBE 2823 F 450 358 4650 service aubetech com For more information on our products visit us at www aubetech com 400 114 000 B 21 2 05 2 2 d technologies Applications The PB112 024T 15S power base can be used on any TH11x series thermostat with the exception of the TH110 model This low voltage power base operates on 15 second cycles and can be connected to a line voltage load using a solid state relay The PB112 024T 15S is compatible with most solid state relays however the following Aube relays are optimized for use with this power base RT850 solid state relay SSR e RT850T solid state relay SSR with built in 24 V transform
3. aube technologies 1 Description Aube s TH114 Series non programmable thermostats can be used to control ambient or floor temperature The following models are available A model gt controls and displays the ambient temperature F model gt controls and displays the floor temperature gt uses an external temperature sensor AF model gt controls and displays the ambient temperature gt maintains the floor temperature within desired limits gt uses an external temperature sensor GFCI fault light Actual or setpoint temperature Arrow appears fa when the setpoint gt Se pa a is displayed CES EEE 44 GEL GFCI fault indicator 110 24 k 25 to 49 Temperature f 50 to 74 adjustment button 75 to 99 J GFCI test button 444 100 o Backlight button On Standby button available on certain models only Each thermostat consists of a control module which must be mounted on a PB112 Series power base For the selection and installation of the power base refer to its installation instructions 2 DIP Switch Configuration The DIP switches are located at the back of the control module 2 1 Temperature Display S1 To switch between C and F 2 2 Model S2 Note Available on certain models only F To select the F model AF To select the A or AF model TH114 TH114 User s Guide Non program
4. er WARNING This power base MUST be used ONLY with solid state relays The use of electromechanical relays will result in reduced life expect ancy and in the possibility of overheating of these devices Supplied Parts One 1 power base Two 2 plastic anchors Two 2 mounting screws Installation Guidelines gt For a new installation choose a location about 1 5 m 5 ft above the floor gt The thermostat must be installed on an inside wall facing the heating system except for floor heating systems gt Avoid locations where there are air drafts top of staircase air outlet dead air spots behind a door direct sunlight or concealed chimney or stove pipes except for floor heating systems Installation Procedure The installation must be carried out by an electrician and com ply with local electrical codes Turn off power to the heating system at the main electrical panel to avoid electrical shock Wire the base according to your application See typical wiring diagrams in sections 4 1 and 4 2 c Fora floor heating system installation con f Th ow nect the floor sensor between the S and R ter alr minals ei S Secure the base to the wall using the provided screws and wall anchors Configure the switches located on the control module if any Refer to the user guide PB112 024T 15S PB112 024T 15S Installation Instructions
5. ing system from the main electrical panel and call customer service Note If the Fault light is On during normal operation cut power to heating system at the main electrical panel and have an electrician verify the installation 400 114 000 B 21 2 05 1 2 7 Operation 7 1 Backlight When either of the amp W buttons is pressed the display is lit for 10 seconds The setpoint appears for 5 seconds then the actual tem perature is displayed When the backlight button is pressed the display is lit for 5 sec onds NOTE f the thermostat is mounted on a GFCl equipped power base this button is used for the GFCI test 7 2 Displaying and Setting the Temperature The thermostat normally displays the actual temperature To view the setpoint press once on one of the A W buttons The setpoint is displayed for 5 seconds During the setpoint display press one of the AW buttons to change it To scroll the setpoint faster press and hold the button 7 3 Setting the Floor Temperature Limits AF model only The thermostat generally turns heating On or Off to con trol the ambient temperature However if the floor tem perature drops below the set minimum floor temperature limit or rises above the maximum limit the thermostat will turn heating On or Off respectively regardless of the ambient temperature to maintain the floor temperature 207 within the desired limits Floor min E m 1L1 8 The minimum and maximu
6. m floor temperature limits are factory set at 10 C 50 F and 28 C 82 F respectively To modify the limits proceed as follows Switch the thermostat to Standby While pressing any button switch the thermostat back to On to access the floor temperature limit settings 2 Press the Test button briefly to switch between minimum and maximum floor temperature settings Press the AY buttons to set the desired limit Press the Test button for 3 seconds to save your modifications After the data are saved the thermostat displays the actual ambient temperature or Note Your modifications are also saved if no button is pressed for 60 seconds Switch the thermostat to Standby and back to On to reset the GFCI and return to the normal display TH114 8 Technical Specifications Power supply Refer to the power base installation instructions Ambient setpoint range A AF models 5 C to 30 C 40 F 86 F Floor limit range AF model 5 C to 40 C 40 F 104 F Floor setpoint range F model 5 C to 40 C 40 F 104 F Setpoint resolution 0 5 C 1 0 F Display resolution 0 5 C 1 0 F Duty cycle Refer to the power base installation instructions Storage 20 C to 50 C 4 F 120 F AUBE TECHNOLOGIES INC ONE 1 YEAR LIMITED WARRANTY This product is guaranteed against workmanship defects for a one year period following the initial date of purchase During this period A
7. mable Thermostat 3 Installation Refer to the installation instructions of the power base Insert the tabs at the top of the control module in the slots at the top of the power base Secure the control module using the cap tive screw underneath the base Note Do not obstruct the thermostat s vents As soon as the thermostat is powered it undergoes a series of tests before displaying the actual tempera gg t cS ure 5 Error Messages Lp The measured temperature is below 0 C 32 F Heat 14999 ing is turned On HI The measured temperature is above 50 C 122 F A or AF model or 60 C 140 F F model E The floor sensor is defective or not properly connected F model only or the thermostat is defective 6 GFCI Test Note This procedure must be performed if the thermostat is mounted on a GFCl equipped power base Test the GFCI immediately after installing the control module and once a month there after Raise the temperature A until the heat ing power indicator appears Press the Test button A ifthe test is successful you will hear a gt click caused by the GFCI relay tripping L The heating power indicator will disap ES pear GFI will appear and the Fault light Cae 3 will illuminate Reset the thermostat by switching it to Standby and back to On Ifthe test has failed cut power to the heat