1. on high and or low outdoor temperatures e Display outdoor temperature and humidity on thermostat INSTALL BATTERIES INTO WIRELESS OUTDOOR SENSOR 1 Remove the cover of Wireless Outdoor FIGURE 1 Sensor to access battery compartment See Figure 1 2 Install two fresh Lithium AA sized batteries Batteries included 3 Replace cover 90 1788 N o Replace cover on 8910 INSTALLATION OF WIRELESS MODULE INTO 8910 EQUIPMENT CONTROL MODULE Disconnect power to 891 Equipment Control Modu Remove cover from 8910 Equipment Control Modu Remove and discard 8910 Equipment Control Modu wireless slot cover See Figure 2 Insert Wireless Module i 8910 Equipment Control Module See Figure 3 0 le le le nto Equipment Control Module Reconnect power to the 8910 Equipment Control Module FIGURE 2 90 1785 FIGURE 3 VIEW THRU WINDOW TO ALIG N PINS 90 1786 HOW TO LINK WIRELESS OUTDOOR SENSOR URES 1 Remove the cover of Wireless Outdoor Sensor and FIGURE 4 8910 Equipment Control Module 2 Press and hold the link button on the Wireless Outdoor Sensor for 3 seconds the green LED will begin to flash slowly See Figure 4 The Sensor is now in linking mode and will wait 5 minutes for a linking signa
2. F 3 F accuracy 0 F to 120 F Humidity measurement range accuracy 0 RH to 100 RH 5 RH accuracy 20 RH to 80 RH Battery life Approximately 2 years Battery type 2x Lithium AA size 1 5V ERROR CODES The 8910 can display these error codes related to the Wireless Outdoor Sensor CHECK WIRELESS OUTDOOR SENSOR The 8910 Equipment Control Module cannot connect to Wi batteries are good and installed correctly Confirm sensor bringing the sensor closer to the Equipment Control Modu interference Then follow the linking procedure to reconnect reless Outdoor sensor Confirm ocation is not an issue by e or away from potential REPLACE WIRELESS SENSOR BATTERY Low Batteries in Wireless Outdoor Sensor Replace batteri size AA 1 5V only es in the Sensor with Lithium CHECK ECM WIRELESS MODULE The 8910 Equipment Control Module cannot detect the Wi installation procedure reinstall the Wireless Module into Then follow the linking procedure to reconnect reless Module Follow the he Equipment Control Module FIVE YEAR LIMITED WARRANTY Your Research Products Corporation Aprilaire Wireless Outdoor Temperature and Humidity Sensor is expressly warranted for five 5 years from ate of installation to be free from defects in materials or workmanship Research Products Corporation s exclusive obligation under this warranty shall be to supply without charge a replacement for any sensor whi
3. ch is found to be defective within such five 5 year period and which is returned together with the date of installation no later than thirty 30 days after said five 5 year period by you to either your original supplier or to Research Products Corporation Madison Wisconsin 53701 HIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS N WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE SENSOR ITSELF MPLIED WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED THIS LIMITED WARRANTY IS VOID IF DEFECT S RESULT FROM FAILURE TO HAVE THIS SENSOR NSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusions or limitations may not apply to you his warranty gives you specific legal rig
4. ent Control Module Range varies with building material types 4 See Figure 6 e Away from large metal obstructions that could reduce wireless communication range a 4 Insert sensor onto bracket and slide e Away from direct rainfall the unit is water resistant not water proof down to secure See Figure 7 e On a vertical exterior wall at least 6 inches below any overhang e Protected from direct sunlight north side recommended 90 1783 e At least 3 away from exhaust vents and condensing lines e Above the snow line e Accessible for easy battery replacement 2 IMPORTANT Confirm the wireless connection at the desired location prior to installing the mounting bracket To confirm the wireless connection place the wireless outdoor sensor near the desired mounting location Confirm the outdoor temperature and RH continue to display at the 8910 user interface and there are no wireless outdoor sensor errors Note If there is a problem with the wireless connection it will take up to 10 minutes for the temperature and RH to stop displaying and wireless error codes to appear see ERROR CODES section for more details It is recommended that you wait 10 minutes before proceeding to step 3 90 1784 SPECIFICATIONS Communications Wireless 900 MHz Wireless range Up to 100 feet Temperature measurement range accuracy 31 F to 135
5. hts and you may also have other rights which vary from state to state his equipment if installed in strict accordance with the manufacturer s instructions complies with the limits for a Class B computing device pursuant to Subpart J of Part 15 of FCC Rules WARRANTY REGISTRATION Visit us on line at www aprilaire com to register your Aprilaire product If you do not have on line access please mail a postcard with your name address phone number product purchased and date of purchase to Research Products Corporation P O BOX 1467 Madison WI 53701 Your Warranty Registration information will not be sold or shared outside of this company FCC DECLARATION IC STATEMENT Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency ene
6. is e aux deux conditions suivantes oit pas produire 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le susceptible d en fonctionnement rouillage est compromettre le P O Box 1467 Madison WI 53701 1467 Phone 800 334 6011 Fax 608 257 4357 www aprilaire com 61000908 4 12 B2205769A 2012 Aprilaire A division of Research Products Corporation
7. l 3 Now press and hold the link button on the 8910 Equipment Control Module for 3 seconds see Figure 5 both green On LEDs on the sensor and control module will begin to hree flash rapidly indicating the units are in the process fee serite of linking Then both green LEDs will go solid for 2 minutes then off The modules are now linked ii Note If the 8910 does not already have the outdoor sensor enabled you will need to enable by setting system setting 11 OUTDOOR Rb O SENSOR of the Installer system settings to YES SISSISVeg SVeg VCIVISVIOsQ at the 8910 user interface TA Note If a wired outdoor sensor is already installed f the wireless outdoor sensor will take priority If a X wireless outdoor sensor error occurs the 8910 will display the corresponding error and revert to the wired Me Q outdoor sensor reading yii _ en _ 90 1793 HOW TO MOUNT THE WIRELESS OUTDOOR SENSOR CUBES pe 1 Select a mounting location 3 Mount bracket with the appropriate type of screws not supplied e Within 100 feet of the 8910 Equipm
8. rgy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help FCC RF Radiation Exposure statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body rilaire Operation is subj two conditions interference an device aux appareils ra 1 l appareil ne de brouillage et ect to the following 1 This device may not cause 2 This device must accept any interference including interference that may cause undesired operation of the Le pr sent appareil est conforme aux CNR d Industrie Canada applicables io exempts de icence L exploitation est autor
9. rilaire Wireless Outdoor Temperature and Humidity Sensor Accessory Model 8056 Wireless Outdoor Temperature and Humidity Sensor Accessory for the l Model 8910 Home Comfort Control Installation and i Operator s Manual OO READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Feat Se esna eE 2 Specifications 00 0 saseni eee eee 10 Install Batteries into Wireless Outdoor Sensor 3 Error Codes 2 0 0 0 0c e cece cece eee 10 Installation of Wireless Module into Limited Warranty 0 000 0 cece 11 8910 Equipment Control Module 4 FCC Declaration 0 0000 e cece eee 12 How to Link Wireless Outdoor Sensor 6 CStatement eee eee 12 How to Mount the Wireless Outdoor Sensor 8 FEATURES In heat pump mode the Wireless Outdoor Sensor can be used to efficiently utilize an air source heat pump e When the outdoor temperature is less than the Low Balance Point the heat pump will be locked out and only auxiliary heating will be used e When the outdoor temperature is higher than the High Balance Point the auxiliary heating will be locked out and only heat pump will be used to provide heating Indoor Air Quality functions can use the Wireless Outdoor Sensor e Control humidification setpoint based on outdoor temperature to prevent condensation e Lock out humidification for temperatures over 60 F or below 30 F e Lock out ventilation based