Home

APC CP27 User's Manual

image

Contents

1. Application of Council Directives 73 23 EEC 93 68 EEC 89 336 EEC Type of Equipment Uninterruptible Power Supply Model Numbers CP27U13UR3 G CP27U13AZ3 CP27U13SC3 Manufacturers American Power Conversion American Power Conversion APC Suzhou UPS Co Ltd Ballybritt Business Park 2nd Street 339 Suhong Zhong Lu Galway Ireland PEZA Cavite Economic Zone Suzhou Industrial Park Amercian Power Conesioh Rosario Cavite Suzhou Jiangsu 215021 Ke RANE Philippines P R China Breaffy Rd Castlebar Co Mayo Ireland American Power Conversion APC Brasil LTDA Lot 10 Block 16 Phase 4 AI Xingu 850 American Power Conversion PEZA Rosario Cavite Barueri 132 Fairgrounds Rd Philippines Alphaville Sao Paulo West Kingston RI 02892 USA 06455 030 Brazil American Power Conversion American Power Conversion 1600 Division Rd Lot 3 Block 14 Phase 3 West Warwick RI 02892 USA PEZA Rosario Cavite Philippines American Power Conversion 40 Catamore Blvd East Providence RI 02914 USA APC India Pvt Ltd 187 3 188 3 Jigani Industrial Area Jigani Bangalore 562106 Karnataka India Importer American Power Conversion A P C b v Ballybritt Business Park Galway Ireland Galway Ireland Ray S Ballard Managing Director Europe fates 5 Jan 05 as N Billerica MA U S A Richard J Everett Sr Regulatory Compliance Engineer Limited Warranty American Power Conversion APC warrants its products t
2. the alarm has been Enable Disable enabled two quick beeps will be emitted Replace Battery 8 12 seconds If the alarm has been silenced the unit will Permanently emit one quick beep If the alarm has been Enable Disable enabled two quick beeps will be emitted Battery Self Test 4 8 seconds If the self test has been enabled three beeps Enable Disable will be emitted If the self test cannot be enabled a single beep will be emitted If the battery self test has been canceled the unit will emit four beeps A battery self test cannot be enabled unless the following conditions have been met 1 Battery has been charged for at least 31 hours 2 The unit has been on utility power for more than 12 hours 3 Temperature is between 0 and 50 C Output Power and Communication Signals The PowerShield communication signals are isolated from its internal circuitry via open collector opto coupled transistors The connection labeled Signal Return is a common return point for all communication signals In the typical application the attached equipment digital ground connects to Signal Return and pull up resistors turn the open collector signals into logic levels Voltage output Voltage output SIG RINY Signal return ON BATT a Lovv vvhen operating from utility line Open vvhen operating from battery REPLACE BATT J Low when battery is charged Open when battery fails the Self Test BATT MISSINGEG Low whe
3. Arc www apc com Broadband PowerShield Models CP16 and CP27 User Manual 990 2366A 04 2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony Fiber to the Home Premise FTTH P and other direct current DC equipment applications Safety This manual contains important instructions that should be followed during installation and maintenance of the APC equipment and batteries It is intended for APC customers that set up install relocate or maintain APC equipment Changes and modifications to this unit not expressly approved by APC could void the warranty Failure to observe this warning may result in serious injury death or damage to the equipment Electrical Warnings Do not work alone under hazardous conditions Servicing the PowerShield may require the removal of protective covers as well as connected utility power Use extreme caution during these procedures Check that the power cord s plug s and sockets are in good condition Replacement of fuses or other parts must be with identical types and ratings Substitution of nonidentical parts may cause safety and fire hazards Battery Warning Danger of explosion if the battery is incorrectly connected or replaced Use only APC replacement batteries Unpacking Inspect the unit upon receipt Notify the shipping carrier or product supplier if there is damage The packaging is recyclable save it for reuse or di
4. all APC Customer Support a technician will ask you to describe the problem and try to solve it over the phone If this is not possible the technician will issue a Returned Material Authorization Number RMA If the product is under warranty repairs are free If not there is a repair charge Procedures for servicing or returning products may vary internationally Refer to the APC Web site Select the appropriate country from the country selection field Select Support from the tab at the top of the web page 2 Pack the product in its original packaging Pack the unit properly to avoid damage in transit Never use Styrofoam beads for packaging Damage sustained in transit is not covered under warranty 3 Mark the RMA on the outside of the package 4 Return the unit by insured prepaid carrier to the address given to you by Customer Support Always DISCONNECT THE BATTERY before shipping in compliance with U S Department of Transportation DOT regulations Contact Information Refer to the APC Web site www apc com Regulatory Approvals Us FE RAL oO Assino LISTED a ee 58VA E191450 EC Declaration of Conformity 2005 We the undersigned declare under our sole responsibility that the equipment specified below conforms to the following standards and directives Standards to Which Conformity Declared EN62040 1 1 EN55022 EN55024 EN61000 3 2 3 3 4 2 4 3 4 4 4 5 4 6 4 8 4 11 EN60950 1 IEC60950 1
5. it is fast charging Output Green indicates the unit 1s working properly and DC output power is provided 9 by the battery or the utility povver Replace Battery Red indicates that the battery must be replaced or that the battery is Alarm Silence disconnected See Battery Replacement e J Da Pressing this button will silence the audible alarm See Alarm Silence Button Automatic Self Test The unit automatically performs a self test 31 hours after initial installation Following this a battery self test will occur every 30 days See Alarm Silence Button for manual self test information Audible Alarm On Four beeps in four seconds will be emitted one time only This alarm will sound Battery when the utility power is lost and the unit goes on battery power Low Every five minutes four beeps in four seconds will be emitted This alarm will Battery sound when operating on battery and the battery voltage has dropped below Voltage threshold indicating that less than 20 of available runtime remains Replace Battery Every fifteen minutes there will be a quarter second beep when the battery fails the automatic self test Alarm Silence Button The audible alarms may be silenced by utilizing the dual function Replace Battery Alarm Silence LED button S J i Function Button Operation Description Press and hold for Replace Battery lt 4 seconds If the alarm has been silenced the unit will Temporarily emit one quick beep If
6. n battery is present Open when battery is missing LOW BATT EJ Low when battery is near full charge capacity Open when operating from a battery with less than 20 of available runtime remaining Chapter 4 Maintenance Service Approvals and Warranty Battery Replacement This unit has an easy to replace hot swappable battery Replacement is a safe procedure isolated from electrical hazards You may leave the unit and connected equipment on for this procedure During the self test battery removal and replacement are not recommended For self test disabling see Alarm Silence Button Replace the spent battery with APC replacement battery RBC2 See your dealer or refer to the APC Web site www apc com for information on replacement batteries For battery replacement see Battery Installation Once the battery is disconnected the connected equipment is not protected from power outages Battery Return Facilities list included with RBC2 aN Be sure to deliver spent batteries to a recycling facility found on the Used amp Service APC makes every effort to ensure parts and equipment arrive in working condition Occasionally it may be necessary to return parts and equipment that are not in working condition If the PowerShield requires service follow these steps 1 Contact APC Customer Support through the APC Web site at www apc com Note the product model number the serial number and the date purchased If you c
7. o be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products To obtain service under warranty you must obtain a Returned Material Authorization RMA number from customer support Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase EXCEPT AS PROVIDED HEREIN AMERICAN POWER CONVERSION MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL APC BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment l
8. oss of software loss of data costs of substitutes claims by third parties or otherwise Entire contents copyright 2006 by American Power Conversion Corporation All rights reserved Reproduction in whole or in part without permission is prohibited APC the APC logo and PowerShield are registered trademarks of American Power Conversion Corporation All other trademarks are the property of their respective owners 10
9. spose of it properly Check the package contents The package contains the enclosure the battery to be installed one power cord and the product documentation Specifications General Model Number Input Output Maximum Maximum Battery Signal Signal Type Voltage Current CP16U48 100 240 V 50 60 Hz 1 0 A 48 V 30 V 5 mA 12 V 7 2 AHr 16 VV Spill Proof CP27U13 100 240 V 50 60 Hz 1 0 A Maintenance Free Sealed Lead Acid Environmental Operating Temperature 4 F to 122 F 20 C to 50 C Operating Humidity 5 to 95 noncondensing within enclosure Maximum Operating Elevation 10 000 ft 3 000 m Maximum Storage Elevation 50 000 ft 15 000 m Storage Temperature 4 F to 122 F 20 C to 50 C Battery lifetime is reduced with prolonged storage in high temperature gt 25 C Physical Height x Width x Depth PowerShield 7 5 x 9 5 x3 in 19 x 24 x 7 6 cm PovverShield carton 13 5 x 13 5 x 4 5 in 34 x 34 x 11 cm Weight PowerShield 7 15 Ibs 3 25 kg PowerShield with package materials 9 Ibs 4 kg Chapter 2 Installation Enclosure Installation CCC eee H 7 FO Il Es Indoor Use dl Q Use screws that are appropriate for the weight of this unit and the mounting surface material See Specifications Install the enclosure in a protected area that is free of excessive dust and has adequate airflow Do not operate the PowerShield where the temperature and humidity are ou
10. tside the specified limits See Specifications Battery Cover Release Tabs Battery Installation Red Cable Positive Terminal gd al Terminal Connect Equipment and Povver charges fully during the first eight hours of normal operation Do not expect full battery run capability during this initial charge period The PowerShield battery charges when it is connected to utility power The battery Utility Power Cord Inlet Output Power and Optional Runtime Communication Extension Connector Signals 1 Connect the PowerShield to the application equipment example FTTH P Optical Network Terminal via the seven pin output connector using the appropriate cable must be ordered separately See www apc com for a list of available output cables 2 Plug the PowerShield power cord into the utility power cord inlet and then into the wall outlet Do not overload the wall outlet or circuit Cold Start Feature Upon installation of a charged battery power will immediately be applied to the unit even when utility power is not present Optional Runtime Extension The runtime may be extended by adding the external battery CP20B12BP Chapter 3 Operation Status Indicators and Features Front Panel Status Indicators Utility Solid green indicates the unit is on utility power BR Solid yellow indicates that utility power is not present and the unit is on battery power Flashing green LED indicates the un