AMX NI-700 User's Manual
Contents
1. COM Settings before programming the unit By default the baud rate is set to 38 400 bps For full warranty information refer to the AMX Instruction Manual s associated with your Product s 93 2105 70 REV B TEA 1 09 eA 2009 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX Ill MINNN HENI Iii il AMX reserves the right to alter specifications without notice at any time bateg Java 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0193 fax 469 624 7153 technical support 800 932 6993 www amx com BD POWERED an EAM
2. and blinks when receiving Ethernet data packets Power Port 2 pin 3 5 mm mini Phoenix male connector Operating Temperature 0 C 32 F to 50 C 122 F Operating Humidity 20 85 RH Rear Panel Connectors Cont Operating Environment 2 pin 3 5 mm mini Phoenix female PWR connector 41 5025 4 pin 3 5 mm mini Phoenix female connector 41 5047 6 pin 3 5 mm mini Phoenix female I O connector 41 5063 CC NIRC IR Emitter AC RK Accessory Rack Kit FG515 CC NIRC IR cables FG10 000 11 CC NSER IR Serial cables FG10 007 10 IRX DM IR Sensor FG458 10 and FG458 11 IRX SM IR Sensor FG455 01 PMB Pole Mount Bracket FG531 STS Serial To Screw Terminal FG959 Surface Mount Bracket Accessory FG525 Included Accessories Other AMX Equipment Port Assignment and Functionality NI 700 Port Assignments I O Port Ethernet Ports used by the NI Controller Ethernet Port Usage The on board Master has a built in FTP server 21 20 TCP SSH The SSH port functions using the same interface as 22 TCP Telnet but over a secure shell where it uses SSL as a mechanism to configure and diagnose a NetLinx system Note SSH version 2 is only supported Telnet The NetLinx Telnet server provides a mechanism to 23 TCP configure and diagnose a NetLinx system HTTP The Master has a built in web server that complies 80 TCP with the HTTP 1 0 specification and supports all of the required features of HTTP v1
3. 1 This port is used for unsecure HTTP Internet communication between the web browser s UI and the target Master HTTPS SSL_ This port is used by a web browser to securely 443 TCP communicate between the web server UI and the target Master ICSP Peer to peer protocol used for both Master to Master 1319 UDP TCP and Master to device communications integration This feature on the Master uses by default port 10500 TCP Solutions 10500 for the XML based communication protocol This port is connected to by the client web browser s JVM when integration Solutions control pages are retrieved from the on board Master s web server Note While the NI 700 is capable of receiving 8 and 9 bit characters it cannot receive 7 bit 1 stop bit data from a serial device ex 9600 N 7 1 Connections and Wiring FIG 2 shows the layout of the connectors and components located on the rear of the NI 700 NetLinx Integrated Controller RS 232 422 485 Ports 1 amp 2 Ethernet PORT 2 ETHERNET 10 100 LA PD 12VDC IR RX Port 5 Rear I O Port 4 IR Serial Port 3 AXLink port AXLink LED green PWR FIG 2 NI 700 rear connectors and components Wiring a Power Connection Use a 12 VDC compliant power supply to provide power to the NI 700 through the rear 2 pin 3 5 mm mini Phoenix connector FIG 2 Use the previous power requirements information to determine the power d
4. 2 DB9 connector male can be connected to Components a DB9 port on a PC This port can be used with both Serial and NetLinx commands Configuration DIP Switch Sets the communication parameters for the Program port IR RX LED Red LED lights when IR data is being received via the rear IR RX port IR LED Red LED lights during the transmission of IR or Serial data via the rear IR port I O LEDs Four yellow LEDs light when the rear I O channels 1 4 are active LED indicator for each I O port reflects the state of that particular port Serial LEDs Two sets of red and yellow LEDs light when the rear DB9 Ports 1 amp 2 transmit or receive RS 232 422 or 485 data These LEDs do not reflect changes in either the RTS or CTS when hardware handshaking is used LINK ACT Green LED lights when the Ethernet cable is connected and an active link is established This LED also blinks when receiving Ethernet data packets Status Green LED lights when the Controller is programmed and communicating properly Output Red LED lights when the Controller transmits data sets channels On and Off sends data strings etc Input Yellow LED lights when the Controller receives data from button pushes strings commands channel levels etc ID Pushbutton Sets the NetLinx ID Device only assignment for the device RS 232 422 485 Ports 1 amp 2 Two RS 232 422 485 control ports use DB9 male connectors with XON XOFF transmit On transmit Off CTS RTS cle
5. af EFA For more detailed installation configuration programming file transfer and operating instructions refer to the N 700 and NI 900 NetLinx Integrated Controllers Instruction Manual available on line at www amx com SERIAL TA F CONFIGURATION IR ON RK 5 1 MASTER LIRR T STATUS OUTPUT a 2 INPUT FIG 1 NI 700 NetLinx Integrated Controller front view Overview The NI 700 FG2105 70 is geared to meet the specific control and automation needs of a single room environment where both price and functionality are the driving requirement This product is configured to control a limited number of video players projectors lighting thermostats and other electronic equipment The NI 700 provides support for one IR Serial Output port two RS 232 RS 422 RS 485 ports four Digital Input Output ports and one IR RX port ATTENTION Verify you are using the latest version of NetLinx Studio available for download from www amx com NI 700 Specifications Dimensions e 1 58 x 5 54 x 5 12 4 01 cm x 14 10 cm x 13 00 cm HWD e 1 rack unit high Power e 280 mA 12 VDC Requirement e Power requirements are usage dependant Memory e 64 MB SDRAM not upgradeable e 32 MB Flash chip not upgradeable e 512 Kb of Non volatile SRAM Microprocessor e 304 MIPS Enclosure e Metal with black matte finish Certifications e FCC Part 15 Class B CE and IEC 60950 Front Panel e Program Port RS 23
6. ar to send ready to send and 300 115 200 baud IR RX Port 5 4 pin 3 5 mm mini Phoenix port is used to connect one or more 8 maximum IRX SM swivel mount or IRX DM Decora mount IR receivers The IR RX port functions using AMX IR codes 38 KHz and 455 KHz and works ONLY with AMX IR Receivers such as the IRX DM and IRX SM Digital I O Port 4 4 channel binary I O port for contact closure with each input being capable of voltage sensing Input format is software selectable with interactive power sensing for IR ports Rear Panel Connectors Installation Guide NI 700 NetLinx Integrated Controller NI 700 Specifications Cont IR Serial Port 3 4 pin 3 5 mm mini Phoenix port is capable of supporting high frequency carriers of up to 1 142 MHz with the output being capable of three electrical formats IR Serial Data IR ports support data mode at limited baud rates and wiring distances AXlink LED Green LED indicates the state of the AXlink port AXlink Port 4 pin 3 5 mm mini Phoenix male connector provides data and power to external control devices Ethernet Port RJ 45 port for 10 100 Mbps communication LEDs show communication activity connection status speeds and mode information SPD speed Yellow LED lights On when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps L A link activity Green LED lights On when the Ethernet cables are connected and terminated correctly
7. ault OFF OFF OFF Setting the Configuration Program Port DIP Switch 1 2 3 Disconnect the power supply from the rear 2 pin PWR green connector Set DIP switch positions according to the information listed in the previous Baud Rate Settings table Reapply power to the unit Preparing the NI 700 for Serial Communication 1 2 oo 10 11 12 13 14 Launch NetLinx Studio 2 x default location is Start gt Programs gt AMX Control Disc gt NetLinx Studio 2 gt NetLinx Studio 2 Select Settings gt Master Communication Settings from the Main menu to open the Master Communication Settings dialog box Click the Communications Settings button to open the Communications Settings dialog Click the NetLinx Master radio button from the Platform Selection section to indicate you are working with a NetLinx Master Click the Serial radio button from the Transport Connection Option section to indicate you are connecting to the Master via a COM port Click the Edit Settings button on the Communications Settings dialog to open the Serial Settings dialog and set the COM port parameters used to communicate to the NetLinx Master Click the OK button three times to return to the main application Right click the entry in the Online Tree tab and select Refresh System Assign a System Value by using Diagnostics gt Device Addressing from the Main menu Enable the Change System selection by clickin
8. g on it and then enter the current and new System values Click the Change Device System Number button and when finished click Done Select Tools gt Reboot the Master Controller to access the Reboot the Master dialog then click Reboot to restart the Master and incorporate any changes Once the dialog replies with Reboot of system complete click Done and then click the OnLine Tree tab in the Workspace window to view the devices on the System The default System value is one Right click on the Empty Device Tree System entry and select Refresh System to re populate the list Configuring the NI 700 for Ethernet Communication Before continuing complete the COM port steps above L A Link Activity LED lights aa a SPD Speed LED lights yellow when 1 Connect an Ethernet cable to the unit s rear Ethernet connector green when the Ethernet LIA SPD the connection speed is 100 Mbps 2 Select Diagnostics gt Network Address from the Main menu and enter the pois arexGunaGEictiand and turns Off when the speed System Device 0 for a Master and Host Name information t rminaled correctly is 10 Mbps 3 To configure the Address e Use a DHCP Address by selecting the Use DHCP radio button then click the GET IP button to obtain a DHCP Address from the DHCP Server click the SET IP Information button to retain the new address and then finish the pro FIG 4 Layout of Ethernet LEDs cess by clicking the Reboot Master gt OK buttons No
9. raw The incoming PWR and GND cable from the power supply must be connected to their corresponding locations within the PWR connector Refer to the NetLinx Integrated Controllers Instruction Manual for more detailed wiring connection information RS 232 422 485 Wiring Connector Information FIG 3 shows the pinout and wiring specification information for the rear RS 232 RS 422 RS 485 DB9 Device Ports These ports support most standard RS 232 communication protocols for data transmission NI 700 uses Ports 1 amp 2 DB9 Serial Port pinouts male connector 5 9 RS 232 RS 422 RS 485 4 Pin 2 RX signal Pin 1 RX Pin 1 A strap to 9 Pin 3 TX signal Pin 4 TX Pin 4 B strap to 6 1 7 Pin 5 GND Pin 5 GND Pin 5 GND 6 Pin 7 RTS Pin 6 RX Pin 6 B strap to 4 Pin 8 CTS Pin 9 TX Pin 9 A strap to 1 FIG 3 RS 232 422 485 DB male connector pinouts WARNING When wiring the 422 485 connections do NOT use pre made 9 wire cable or connect the wire in the cable to any connection that will not be used by the DB9 serial port Only use wiring that connects the needed pins Ethernet 10 100 Base T Connector A standard CAT5 Ethernet cable provides 10 100 network connectivity between the Integrated Controller and the network FIG 4 Note DIP switch 1 activates deactivates the Program Run Disable Mode DIP Switches 2 3 and 4 must remain OFF at all times Baud Rate Settings 9600 bps OFF 38 400 bps def
10. te On NetLinx Masters such as those aboard the NI 700 from within the Telnet Use a Static IP Address by selecting the Specify IP Address radio button or Terminal applications you can send the SET ETHERNET MODE command to enter the IP parameters into the available fields then click the SET IP Informa assign the speed of your Ethernet connection tion button fo retain the pre reserved IP Address to the Master and then click the Reboot Master gt OK buttons to finish the process Sample NI 700 command 4 Repeat steps 1 5 from the previous section but rather than selecting the SET ETHERNET MODE AUTO Serial option choose TCP IP and edit the settings to match the IP Address The NI 700 only allows you to set the Ethernet mode to AUTO negotiate the ae saa qwneiner Static a IP Ethernet connection speed Using any of the other connection modes 10 Half 5 Click on the Authentication Required radio box if the Master is secured and Full or 100 Half Full results in an error message press the User Name and Password button to enter a valid username and password being used by the secured Master Program Port Baud Rate Settings 6 Click the OK button three times to return to the main application The Configuration DIP switch is located on the front panel Use this DIP switch to set the baud rate for the Program Port according to the settings shown in the following table Make sure the baud rate you set matches the baud rate on your PC s NetLinx