Home

AMX Mio Modero Dms Keypad User's Manual

image

Contents

1. FIG 2 Mio Modero DMS Rear Components Connections and Wiring The Mio Modero DMS device is powered either via 12VDC or Power over Ethernet PoE If both the 12 VDC and PoE power sources are connected by default the device draws power from the 12 VDC If the 12 VDC source is disconnected the PoE will automatically supplies power after a device reboot Note Do not connect power to the Mio Modero DMS until the wiring is complete Preparing captive wires for the 2 pin 3 5 mm mini Phoenix connector You will need a wire stripper and flat blade screwdriver to prepare and connect the captive wires 1 Strip 0 25 inch 6 35 mm of wire insulation off all wires 2 Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section 3 Turn the screws clockwise to secure the wires in the connector Note Do not over torque the screws doing so can bend the seating pins and damage the connector Using the PSN NetLinx connector for power The PWR and GND wires from the 12 VDC power supply must be connected to the corresponding location on the 2 pin 3 5 mm mini Phoenix connector See the KeypadBuilder Instruction Manual for an illustration 1 Insert the PWR and GND wires on the terminal end of a PSN 2 pin 3 5 mm mini Phoenix cable Match the wiring locations of the on both the power supply and the terminal connector 2 Tighten the clamp to secure the two
2. Mio DMS Installation Using Either Expansion Clips or 4 40 Screws 3 Thread the CAT5 CAT6 and if necessary the power cables through one of the provided breakaway access points on the backbox Leave enough slack in the wiring to accommodate any re positioning of the unit 4 Insert the backbox into the cutout until the rim of the backbox is flush against the wall 5 Insert and secure four 4 40 mounting screws not included into their corresponding holes located along the sides of the backbox until it is flush against the wall Or use the expasion clips at this time 6 Connect the 2 pin power connector and or CAT5 CAT6 cables in the back of the Mio DMS See FIG 2 for port locations 7 Insert and fasten the Mio DMS into the backbox start at the top of the device and tilt in toward the bottom Device Setup The Mio DMS is equipped with firmware pages that allow you to set and configure various features of the device Some menu items are compulsory Necessary Device Setup while other items are optional Optional Device Setup section on page 28 of the instruction manual To navigate the pages in the Mio DMS press More to view more options within the selected menu Press Return to go back a page and accept changes made Note Confirm your NetLinx master has the latest version of Nexus compliant firmware The firmware must be UDP and NDP settings compliant v 323 or higher Accessing The Setup Page If you have not loaded
3. any pages on your Mio DMS device it will launch the Setup page by default Otherwise press and hold down the Up and Down buttons for 3 seconds Necessary Device Setup The following sections must be set on your Mio DMS IP Settings The configuration of the Mio DMS requires you set the communication protocol Your options are either Static or DHCP Consult the Mio DMS amp Mio DMS Pinnacle instruction manual for setting Static From the Setup page follow these steps 1 Push the button that corresponds to Protected Setup If you do not have a password established the device will not prompt you for one The default pass word is 1988 2 Select the button for IP Settings 3 Select the button for DHCP 4 In the DHCP page select the button for DHCP to toggle the protocol between DHCP and Static 5 Select the button for Return to accept that change Consult the Mio DMS amp Mio DMS Pinnacle instruction manual for setting a Host Name AMX Corporation reserves the right to alter specifications without notice at any time Mio DMS Menu Navigation Follow these tips to set your device information e The Up and Down buttons scroll through numerals upper case and lower case letters e Accept Char enters the current value and moves the cursor to the right e Backspace moves the cursor to the left e Clear removes everything listed e Abort exits the edit page without keeping changes e Done accepts changes and returns to
4. the previous page Master Connection 1 Push the button that corresponds to Protected Setup If you do not have a password established the device will not prompt you for one Select the button for Master Connection 2 3 Select the button for Connection Mode 4 Select the button next to the listed mode to toggle through the available con nection modes Connection Modes Moge pesoripton Procesus The device connects to the Setting the System Number first master that responds 1 Within the Master Connection menu This setting requires you set select the button for System Number the System Number this set 2 To change the System Number from what is ting is available in the Master listed press the button next to the System Num Connection menu ber to enter the edit page See Mio DMS Menu Navigation for help 3 After you have set your System Number and pressed Done press Return to finalize your changes and go back to the Master Connection page The device connects to the Setting the Master IP specific IP of a master via a 1 Select the button next to More TCP connection This setting 2 Select the button next to Master IP requires you set the Master s To change the Master IP from what is listed IP press the button next to the Master IP number to enter the edit page See Mio DMS Menu Navigation for help 4 After you have set your Master IP and pressed Done press Return to finalize your changes and go bac
5. wires 3 Verify the connection of the 2 pin 3 5 mm mini Phoenix to the power supply Using the Ethernet port for power PoE Connect your CAT5 CAT6 Ethernet cable to the port shown in FIG 2 See the Mio Modero DMS amp Mio Modero DMS Pinnacle instruction manual for an illustration and cable pinouts Mounting Procedures FIG 3 shows the mounting dimensions for the Mio Modero DMS Reference these measurements when planning and installing the device Consult the Mio Modero DMS amp Mio Modero DMS Pinnacle instruction manual for other installation methods Flat Surface Installation It is recommended that you cutout the surface slightly smaller than what is outlined in the installation drawings so that you can make any necessary cutout adjustments Before you begin if you are using the 2 pin power connector verify that the terminal end of the power cable is not connected to a power source 1 If assembled remove the Mio Modero DMS from the backbox Place a flathead screwdriver between the tab of the backbox and the notch of the Mio Modero DMS see FIG 2 and pry the two apart 2 Cut out the surface for the Mio Modero DMS backbox using the dimensions shown in FIG 3 A template is included to help you determine dimensions Notch Only required for solid surface mounting Use 4 screws 2 00 508 1 CUTOUT 1 00 25 4 K fi M S BEZEL OUTLINE 54 9 84 J 0150 FIG 3
6. Baa are IT S YOUR WORLD TAKE CONTROL Overview The Mio Modero DMS device family provides a wide range of control capabilities in the form of user specified buttons that are functional yet recherch Mio Modero DMS keypads are equipped with an LCD menu display with 8 pushbuttons for navigation and menu selection Menu Up Menu items Menu select pushbuttons Security HVAC Watch Listen Lights Blinds 75 Menu Down FIG 1 Mio Modero DMS Device Family Specifications Mio Modero DMS FG2408 01XX Specifications Power 12 VDC PoE Maximum power consumption PoE 5 5 Watts Maximum startup rush current PoE 150 mA 50 VDC Maximum continuous current PoE 100 mA 50 VDC Maximum power consumption DC 5 0 Watts Maximum startup rush current DC 525 mA 13 5 VDC Maximum continuous current DC 350 mA 13 5 VDC Front Panel Components e LCD display e 8 pushbuttons Rear Panel Connectors e Ethernet Port PoE e 2 pin 3 5 mm min Phoenix female connector Dimensions HWD e 4 50 114 3 mm x 3 50 91 4 mm x 2 88 73 mm Supported Fonts Only True Type Fonts Weight range e Device 45 lbs 20 kg e Back box 20 Ibs 09 kg Operating Environment e Operating Temperature 0 to 40 C 82 to 104 F e Storage Temperature 10 to 60 C 14 to 140 F The Mio Modero DMS is installed in one of two ways e 4 screws for hard surface mounting e 2 expansion clips for
7. k to the Master Connection page Confirm device IP is on the Master URL list You can set the Host Name on the device and use it to locate the setting requires you provide device on the master Host Name is particularly useful the master with the device s in the DHCP scenario where the IP address can IP change NDP The device is available via Use the master web interface NetLinx Studio or UDP Nexus Discovery Protocol commands to bind the DMS device to the master URL The device connects to the Setting the Master IP UDP specific IP of a master via 1 Select the button next to More UDP 2 Select the button next to Master IP To change the Master IP from what is listed press the button next to the Master IP number to enter the edit page See Mio DMS Menu Navigation for help 4 After you have set your Master IP and pressed Done press Return to finalize your changes and go back to the Master Connection page The device listens for the master to initiate contact This 5 Press the button for More to view the second page of the Master Connection menu 6 Press the button for Master Port The default setting for the port is 1319 Press the button next to the master port number to access the edit page and change this value See Mio DMS Menu Navigation for help 7 After you have set your Master Port and pressed Done press Return to final ize your changes and go back to the Master Connection page If you have enab
8. led password security on your master you need to set the username and password within the device 8 Press the button for Username If no username has been set the field is blank Press the button that correlates to the blank field just below Username See Mio DMS Menu Navigation for help 9 After you have set your Username and pressed Done press Return to finalize your changes and go back to the Master Connection page Press the button for More Press the button for Password If no password has been set the field is blank Press the button that correlates to the blank field just below Password See Mio DMS Menu Navigation for help 12 10 11 After you have set your Password and pressed Done press Return to finalize your changes and go back to the Master Connection page 13 Reboot device to confirm changes For full warranty information refer to the AMX Instruction Manual s associated with your Product s 041 004 2958 1 06 2006 AMX Corporation All rights reserved The AMX logo is a trademark of AMX Corporation 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0193 fax 469 624 7153 technical support 800 932 6993 e www amx com 93 2408 02 REV A AMDA Lr
9. pressure mounting Available Color Schemes Black BL White WH Beige BG Almond AL Brown BR Gray GR Ivory IV Light Almond LA Taupe TP Gold GL Silver SL Included Accessories e 2 pin 3 5 mm mini Phoenix connector 41 5025 e Mounting kit KA2250 01 Dynamic Menu System Using the KeypadBuilder application available for download from www amx com the Mio Modero DMS is programmed with a Dynamic Menu System DMS that is navigated via the 8 pushbuttons and LCD display area See the KeypadBuilder Instruction Manual for more information on programming Mio Modero DMS devices Quick Start Guide Mio Modero DMS Keypad Installation Note To avoid any damage to the electronic component installation must be performed in an ESD safe environment The installation section addresses the mounting and wiring of the Mio Modero DMS After you have completed the installation you must consult Necessary Device Setup Rear Components The rear components of the Mio Modero DMS FIG 2 are as follows Ethernet Port PoE Front View Board Orientation rN This notch coincides US PATENT 6769996 with an indentation in TE Pulse Jack the back box The JK0 0044 We notch is always on the 953A left 2 pin 3 5 mm mini Phoenix female connector SA2408 02 Rev 2 00 Device Removal Notch This notch coincides with a metal tab on the back box The metal tab prevents damage to installation surfaces

Download Pdf Manuals

image

Related Search

Related Contents

Manual de instrucciones - direct  Mode d`emploi lunettes 3D TY-EW3D2LE TY - Migros  antifouine af4500ver10 description  Moodle User Manual for Instructors  S15-4(UK)manual 01 - UMC  télécharger le fichier PDF ici - MRC  MANUAL DE INSTRUÇÕES  Manual del usuario  2009年度 VCCI 規程類改訂内容  263-349 R0515 - SnowBear Plows Inc.  