1. AAmbrican Standard Installation Instructions HORG T038 50X IN WALL PRESSURE BALANCING BATH AND SHOWER TRIM KIT with EverClean Finish Congratulations on purchasing your American Standard faucet with EverClean finish found only on American Standard faucets EverClean Finish e One wipe effortlessly removes spots Eliminates the need for cleaners and scrubbing Permanent surface protectant remains beautiful for the life of the faucet e EverClean available on Polished Chrome Satin Nickel Stainless Steel Polished Brass or any combination of these finishes Certified to comply with ANSI A112 18 1 To ensure that your installation proceeds smoothly please read these M968895 instructions carefully before you begin Required Tools Phillips Screwdriver GDO BALAT Wrench es Tubing Cutter Channel Locks Plumbers Putty or Caulking l 5 32 Flat Blade Screwdriver Hex Wrench ROUGHING IN DIMENSIONS To assure proper positioning in relation to wall note roughing in dimensions gt 3 4 TO 2 3 8 FINISHED WALL 1 2 NPT TO FINISHED USUALLY 65 AND 80 SEE ILLUSTRATION 74 FOR HEAD CLEARANCE 18 OPTIONAL TOP OF TUB RIM BOTTOM OF TUB P INSTALL TRIM CAUTION Protect finish on SHOWER ARM SHOWER HEAD and TUB SPOUT when installing When finished tiling the wall remove PLASTER GUARD A and turn off
2. CARTRIDGE 4 and NUMBERS 5 on HOT LIMIT STOP 1 for indication Smaller Numbers 9111315 COLDER Larger Numbers 013570989111315 M968895 E If faucet drips operate handle several times from off to on Do not apply excessive force m Clogged CARTRIDGE 1 inlets may cause reduced flow in full on hot or cold To clean inlets first turn off water supply then Remove HANDLE 2 Remove two SCREWS 6 holding ESCUTCHEON 7 and remvoe ESCUTCHEON 7 Remove CAP 3 SCREWS 5 and CARTRIDGE 1 Clean inlets and MANIFOLD 4 E Reassemble CARTRIDGE 1 alternately tightening SCREWS 5 Replace CAP 3 and HANDLE 2 Check flow SERVICE VALVE LEAKS WHEN SHUT OFF E Remove handle and trim E Remove CARTRIDGE 1 by removing CARTRIDGE SCREWS 2 Remove three SCREWS 3 from FIXATION RING 4 and pull out PRESSURE BALANCING 5 unit E Clean SEALS 9 on base of CARTRIDGE 1 Check base of PRESSURE BALANCING UNIT 5 and clean Q RINGS 6 Remove CAPS 7 and check O RINGS on inside of CAPS 7 Clean inside sealing surfaces of VALVE BODY 8 m Re assemble PRESSURE BALANCING UNIT 5 and CARTRIDGE 1 Tighten all screws Turn on water supply and see above for installing TRIM and HANDLE UNABLE TO MAINTAIN CONSTANT TEMPERATURE E Remove PRESSURE BALANCE UNIT 5 E Remove CAPS 7 and clean valve thoroughly m Examine balancing unit and check condition of O ring on end of pis
3. ton Piston should move back and forth Order Repair Part M952100 0070A if balancing unit is defective m Replace CAPS 7 and install PRESSURE BALANCE UNIT 5 Make sure inlets line up with two holes in bottom of casting Top flange should butt up against top of casting BACK TO BACK INSTALLATION E Remove PRESSURE BALANCE UNIT 5 Rotate PRESSURE BALANCE UNIT 5 180 so that the inlets face up and the large outlet port faces down m Push PRESSURE BALANCE UNIT 5 in casting make sure inlets line up with holes in bottom of casting Top flange should butt up against top of casting E Reassemble FIXATION RING 4 and CARTRIDGE 1 i ROTATE 180 0 mee AAN LARGE OUTLET 0 CEG Las A KAF m e xX o e D ve LLS INLETS LS BACK TO BACK INSTALLATION EverClean Finish Care Instructions American Standard s EverClean finish will wipe clean with a soft dry cloth A soft cloth with clean water may also be used if desired No additional cleaning products are required DO NOT USE Soaps acid polish abrasives harsh cleaners or a cloth with a coarse surface y9 8895
4. water supply HEX WRENCH Push CAP 1 over VALVE CARTRIDGE 2 Mount ESCUTCHEON 3 and gasket to valve body with SCREWS 4 Remove PIPE CAP amp PLUG 5 from shower pipe and tub filler pipe Apply Teflon Tape to both ends of SHOWER ARM 6 Install SHOVVER ARM 6 with FLANGE 8 into shower pipe and tighten Thread SHOWER HEAD 7 onto ARM 6 and tighten E Push SHOWER ARM FLANGE 8 to wall and tighten SET SCREW 9 with 5 64 hex wrench Install SLIP ON DIVERTER SPOUT 10 onto filler pipe and tighten INSTALL HANDLE and TEST FITTING Install ADAPTER 1 onto VALVE STEM 2 using SCREW 3 Align and install HANDLE 4 and tighten with SET SCREW 5 using 2 5mm Hex Wrench supplied Check proper operation of HANDLE 4 Turn on water supply on and test installed fitting Operate valve and diverter spout HEX WRENCH _ _J ADJUST HOT LIMIT STOP By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold the HOT LIMIT SAFETY STOP 1 reduces risk of accidental scalding To set the maximum hot water temperature of your faucet all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP 1 Turn CARTRIDGE STEM 2 to the OFF position coldest setting before making adjustment to HOT LIMIT STOP 1 Use a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP 1 Pull forward and rotate counterclockwise one number to limit hot water temperature Use ARROW 3 on

Download Pdf Manuals

image

Related Search

Related Contents

Manual de Utilização Mestre PROFIBUS-DP NX5001  MODEL RL1600 USER MANUAL  installation r50  ソケット型録画装置 取扱説明書 型番:BMR036 電源ソケット型の  User guide (EN) for Explorer 710 - E-SAT  Refrigerator - Trail Appliances  地中・壁裏ケーブルの位置と深さが簡単に分かります!  User manual  Philips FWD798 DVD Mini Hi-Fi System  Bruger manual - UniRo 5000SW  

Copyright © All rights reserved.
Failed to retrieve file