1. Installation Instructions TROPIC 7038 201 Centerset Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain a feature found only on American Standard faucets Certified to comply with ANS A112 18 1 M968891 Rev 1 1 Speed Connect Drain Fewer parts installs in less time Never needs adjustment Guaranteed to seal properly the first time every time Your new American Standard faucet is designed to work only with the Speed Connect drain To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Recommended tools Screwdriver Channel Locks Adjustable Wrench Tubing Cutter 1l INSTALL FAUCET cauTION Turn off water at main supply Turn off hot and cold water supplies before beginning Em Insert FAUCET 1 and CABLE CONNECTOR 2 through mounting holes of Sink or mounting surface Fig A m Assemble LOCKNUTS 3 onto SHANKS 4 from under side of Sink Hand tighten firmly Fig B HAND TIGHTEN 3 4 4 SINK OR MOUNTING a 2 ES A POP UP DRAIN m Remove CLEAR PLASTIC COVER 1 m Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B Fig B EJ REMOVE FLANGE Thread FLANGE 1 counter clockwise and remove FLANGE 1 and FOAM GASKET 2 fro
2. ADAPTOR 2 Pull off ADAPTER 2 m Remove SPRING CLIP 4 Lift STOP WASHER 5 turn 90 and replace Replace SPRING CLIP 4 Replace ADAPTER 2 and ADAPTER SCREW 3 m Find correct position of HANDLE ASSEMBLY 1 by adjusting male teeth on ADAPTER 2 to female teeth in HANDLE ASSEMBLY 1 Push HANDLE ASSEMBLY 1 down onto ADAPTER 4 until it snaps into place A CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE M968891 Rev 1 1 Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If Stepper does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver t
3. in Unlocked mode and removable INSTALL CAM Loop TOWARD REAR OF SINK gt So DRAIN Locked Mode Vandal Proof FRONT OF SINK oo Q DRAIN Unlocked Mode M968891 Rev 1 1
4. LIES OR BULL NOSE RISERS MUST BE PURCHASED SEPARATELY m Connect water suppi ta FAUCET 1 with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 0 D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length Connect 1 1 4 O D tailpiece on POP UP DRAIN to 1 2 PIPE n 4 waste outlet THREAD COUPLING 2 NUT FLEXIBLE SUPPLIES cr 3 3 8 O D BULL NOSE RISERS 3 8 COMPRESSION COMPRESSION CONNECTION NUT FERRULE coLD M968891 Rev 1 1 10 TEST INSTALLED FITTING m With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks m m Remove AERATOR 3 m Operate both HANDLES 1 to flush water lines thoroughly Replace AERATOR 3 CHECK DRAIN CONNECTIONS m Operate POP UP KNOB 4 and fill lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in SINK If DRAIN STOPPER 5 does not seal properly please refer to Troubleshoating section in these instructions m Release POP UP KNOB 4 down and check all drain connections and P trap for leaks m Tighten if necessary P TRAP 11 SERVICE To change direction of handle m Turn valve to OFF position m Pull HANDLE ASSEMBLY 1 UP firmly to release from ADAPTER 2 m Remove ADAPTER SCREW 3 from
5. ar of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G m Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J Re install the Cam Cap making sure the guide teeth are facing E outward If the Cam Cap does not snap into place then rotate the Cam to make sure it is fully inserted Fig K a Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Troubling Shooting Guide to complete installation Stopper will be in Locked mode and not be removable Unlocked Mode a Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into m the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down ig H Re install the Cam into the Drain rotating the Cam if necessary m to make sure it is fully inserted Fig J Re install the Cam Cap making sure the guide teeth are facing m Outward If the Cam Cap does not snap into place then rotate the Cam to make sure tt is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Troublingshooting Guide to complete installation Stopper will be
6. m drain body Fig A Thread LOCKNUT 3 clockwise to bottom of drain body Push GASKET 4 down against LOCKNUT 3 Fig B INSTALL DRAIN FROM BELOW FIXTURE m From under side of SINK install DRAIN BODY 1 up through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly H TIGHTEN LOCKNUT Tighten LOCKNUT 1 firmly with Adjustable Wrench or Channel Locks g FLANGE GASKET AND POP UP KNOB Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET 3 is fully compressed and not visible Fig A m POP UP KNOB 1 must be fully down Fig B WHITE FOAM GASKET NOT VISIBLE M968891 Rev 1 1 ATTACH CABLE CONNECTOR m Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 O D Fig B CHECK OPERATION OF POP UP m Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPP
7. o rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 4 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F JCF REMOVE 4 7 cam REMOVE CAM CAP M968891 Rev 1 1 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode m Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G m To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the re